Helium Sniffer Probe User Guide
Contents
1. leak detector or P N LST 30 for all other brands See Step 3 installation instructions 3 A Remove filter tip assembly and B loosen both cord grips and C slide out main sniffing line D While holding tubing connection remove SS tip from urethane tubing Reinstall the end of the new tip assembly with small pin sticking out into the C urethane tubing Take care to not damage pin assembly Reinstall the sniffing line into the handle assembly and retighten the cord A naii LACO Sniffer tip exploded view Installing the filter tip assembly on the LACO Sniffer probe 3085 West Directors Row Salt Lake City UT 84104 Phone 801 486 1004 Fax 801 486 1007 info lacotech com www lacotech com CREATING VACUUM AND LEAK TESTING SOLUTIONS SMT 07 1004 revB2
2. LACGircinoiocies HELIUM SNIFFER PROBES HELIUM SNIFFING TIPS When using a helium sniffer probe to test pressurized components or system ensure that there are no gross leaks in the system prior to pressurizing Gross leaks will allow the surrounding air or background to become contaminated with helium which lowers the sensitivity of the leak test When venting helium from a pressurized test part do not vent in the same area where the testing is performed This will contaminate the surrounding air with helium When the ambient air is contaminated with helium a large fan can be used to exhaust the test area and provide clean air When sniffing a part with multiple potential leak locations always begin sniffing near the bottom of the part and work towards the top It may be necessary to repair leaks that are found before proceeding Helium escaping from the part will rise and can give a misleading leak location PROCEDURE 1 Connect Sniffer probe to Sniffer or inlet Test Port for the leak detector you are using Refer to the leak detector user manual for instructions Sniff leak test per the leak detector user manual instructions While testing do not plug or contaminate the sniffer probe tip If the probe becomes plugged or dirty remove the clear tube and filter assembly from the tip Replace with a spare unit supplied with the sniffer probe Slide the clear tube over the stainless steel tube s
3. o the filter rests at the end of the probe tip If probe is still clogged see sniffer tip replacement procedure 3085 West Directors Row Salt Lake City UT 84104 CREATING VACUUM AND LEAK TESTING SOLUTIONS Phone 801 486 1004 Fax 801 486 1007 USER GUIDE USE OF PROBE TIPS The sniffer probe tip uses vacuum which can pull oil grease and other contaminants into the line that may be harmful to the sniffer probe and leak detector Make sure the probe tip does not get plugged CAUTION Follow precautions to ensure safe operation A e Do not allow moisture to be drawn into the probe e Do not inhale helium gas Helium is non toxic but may cause suffocation Lack of sufficient oxygen can cause serious injury or death Refer to Material Safety Data Sheet SPARE PARTS LIST PART NUMBER DESCRIPTION LMSA92097 Tip Filter Assembly LST 60 Alcatel version sniffer tip assembly LSP 01A xx Non Alcatel sniffer tip assembly LSP 01N xx or LSP 01HS xx info lacotech com www lacotech com SMT 07 1004 revB2 SNIFFER TIP REPLACEMENT PROCEDURE 1 Often a cloggeded tip can be fixed by running compressed air or nitrogen through the sniffer in test connection Blow 10 40 psi of gas through the probe for 20 30 seconds Retest probe in leak detector to see if the clog has cleared 2 If clog is still present contact LACO for the correct leak tip assembly for your leak detector P N LST 60 for Alcatel
Download Pdf Manuals
Related Search
Related Contents
SLTA-10 Adapter User's Guide Cost attractive model for H61 uATX motherboard with 2 - 取扱説明書ダウンロード be.ez LE vertigo 15 Black Ebene White Knight C37AS tumble dryer Pyramid Technologies PS-52K User's Manual 2007年10月 - カワムラサイクル Copyright © All rights reserved.
Failed to retrieve file