Home
        T-TeleSec LineCrypt L100
         Contents
1.  direction of the  arrow marked    open       Close the cover of the chip card receptacle and slide locking backward  Push  casing top back onto the casing und fasten it with the five screws     Start Up       Start Up    After the appropriate installation  connect the LineCrypt L100 with the mains  cable plug to an earthed socket  The LineCrypt L100 performs a self test   About 45 seconds it will begin normal operation     It is not possible to set up connections with other equipment in the delivery  configuration  To be able to configure encrypted connections with other  LineCrypt equipment or unencrypted connections with other Ethernet devices   a corresponding configuration of the LineCrypt L100 is required  Use the  provided PC program    lec    to configure the LineCrypt     Via the local management you also have the option of configuring authorized  system administrators for remote maintenance     CD configuration software    The accompanying CD contains the configuration software for the LineCrypt  1100  the operating instructions for the software as well as further documents   The latest information can be found in the file    readme txt       Operation       Operation        Extern Intern  es  On      Reset          O Speed O Speed  u ae Oli   O O       Figure 5  front side    In the center of the panel there are four multi colored light emitting diodes   LED   which are labeled  On     Il and Ill     The On LED signals the ready status of the equipment or errors de
2.  gt Authentication awarded by the Deutsche  Telekom  gt TrustCenter is stored on the  gt  NetKey Card     Glossary       TCP IP  Internet Protocol and Transmission Control Protocol   TCP is a connection oriented transport protocol for use in packet  switched networks  The protocol builds on the IP protocol  supports the  functions of the transport layer  and establishes a secure connection  between the entities before data transfer     TCOS  TeleSec Chip card Operating System   Operating system for processor controlled Chip cards  smart cards      VPN  Virtual Private Network     A protected virtual sub network is set up in an unprotected network using  encryption mechanisms     15       Index    Authentication 12  Certificate ID 13   Chip card 12 15   Chip cards 5  Connection scheme 13  Environmental temperature 12  Ethernet 5f   9  12f   IDEA 12   IP Network 14   IP Tunnel 4 14   LAN 14   LED 10f   14   NetKey Card 12 14  Operating System 141   RSA 12    self test 9f   TCP IP 15  VPN 4 15    Important telephone numbers       In the event of malfunctions           Sales enquiries           Please enter the telephone number  when handing over the unit     The LineCrypt fulfils the requirements of the following EU Directive   1999 5 EG    For this reason the LineCrypt bears the CE mark     Responsible for content  T TeleSec Products  Further information      Internet http   www telekom de t telesec  e mail T Telesec telekom de   Issued by    Deutsche Telekom AG    Edition  22 
3.  temperature  41   F to  104   F   5   C to  40   C       Ethernet interface Ethernet interfaces 2 x 100BaseT   100 Mbps  half duplex   full duplex  with  Western RJ45 WE8 8 sockets                PC interface V 24  Mini DIN 8   Chip card T TeleSec NetKey Card  with TCOS 2 x  8x  Payload data encryption IDEA  DES or Triple DES   Authentication RSA             Table 2  Technical Data       Glossary       Glossary    Certificate  Authenticated allocation of a public key for an identity expressed by the  digital signature of a Trust Center  of Deutsche Telekom AG   Each T   TeleSec NetKey Card has an individual certificate    Certificate ID  Number in a certificate that provides the certificate with unambiguous  identification     Company Card   gt TCOS Chip card that  unlike the  gt NetKey Card  contains information  about a closed user group  Company Cards can be obtained from  Deutsche Telekom if required     Connection scheme  Schematic diagram of possible connection variants     EMC   Electromagnetic compatibility  The ability of an appliance  installation  or system to function satisfactorily  in the electromagnetic environment without introducing electromagnetic  interference to any appliance or system in that environment  quoted from  the EC EMC guideline  article 1  clause 4      Ethernet  The most widely used  gt LAN standard  Local Area Network   Supports  data rates of up to 10 Mbps  10Base T  or 100 Mbps  100Base T      IP  Internet Protocol   The task of the Intern
4.  the LineCrypt        Installation place    The LineCrypt L100 comes in a 19  rack mount casing for installation in a 19   rack     The installation place should be dry and free from dust  The LineCrypt is  designed for an environmental temperature range of   5   C bis   40   C   Therefore  do not expose the LineCrypt in direct sunlight and be sure that  there is sufficient ventilation     Installation          Inserting and removing SIM chip cards    The LineCrypt L100 has eight chip card slots  To insert  remove or replace the  chip cards in the device its casing must be opened  The eight chip cards must  be of the same typ  comany or netkey cards                                                                                                                                rar                                              d                                                                      147  50  ee chip card chip card  aa a 5 6  ule cm  Em H Ar a  BIETEN g s E  az    A  chip card chip card  El sz oz ar     ESA 7  U2 UF  8  ZE g g D  e    om  chip card chip card   chip card   chip card                                                                                        x    reas   o  gt  AAA O    Figure 4  Seat the chip card    Before opening the casing pullthe power plug  Remove the five screws atthe  rear side of the casing with a crosstip screwdriver  Slide the casing cover off  horizontally backward     To replace a chip card the locking of the chip card slot in the
5. 09 03  Subjectto change without notice    
6. T TeleSec LineCrypt L100    User s Guide    Deutsche T  Telekom       Contents       Overview of pictorial SYMDOIS x4 sor ri re dial La lo da 3  DAIEDITIOTES tala is elit idad toi 3  Power Tale sanctus 3        A sr 5  A O a E ne a reste aor 6  Installation place nes in see es ee T  Inserting andremovngSIM chipeardssuest are ea 8          Registered trademarks  trademarks  and service names are used in this manual   Even if they are not marked as such  the relevant protection regulations apply     IDEA    is a trademark of Ascom Systec AG    General       General    We strongly recommend that you read this user manual before using  LineCrypt  Deutsche Telekom cannot be held liable for any possible damage  caused to the device or other facilities arising from the failure to follow the  instructions in this manual     Overview of pictorial symbols    Safety symbol to warn against danger for people and property is identified with  a triangular warning sign     Safety notes    e Allow no liquids to seep into the LineCrypt      Do not plug in or detach any connections to the LineCrypt during a  thunderstorm    e The LineCrypt is only intended for use in dry indoor areas    e Lay the cables so that no one can step on them and trip    e Before any maintenance work on the LineCrypt pull out the mains plug    e Only terminal equipment that complies to the SELV voltage standard may be  connected to the LineCrypt L100   e Connect the device to a freely accessible earthed socket so that 
7. et Protocol  IP  layer 3  is to transport data packets  from a sender to a receiver across several networks  The transmission is  packet oriented  connectionless  and non guaranteed  The data packets    13    Glossary        also called datagrams  are transported by the IP as independent data  packets  even in the case of identical senders and receivers   IP  guarantees neither observance of a particular sequence nor delivery to  the receiver  that is  datagrams can be lost on account of network  overload  for example   There are no receive acknowledgements on the  IP layer     IP Network  Network based on the Internet Protocol  Every device in the network is  addressed through an IP number     IP Tunnel  A connection between two subnetworks  which conceals the precise  addresses of the communication partners  At the start of the tunnel  all  data packets receive an additional header that refers to the tunnel end   Here the external frame is removed and the original data packet is  forwarded to its actual receiver     LAN  Local Area Network   A spatially restricted network  The most widely used LAN standard is  Ethernet     LED   Light Emitting Diode  For displaying the operational status of the device and of the connection     LineCrypt Company Card  Special chip cards with information on closed user groups  Can be  obtained from Deutsche Telekom if required     NetKey Card  SmartCard with  gt  TCOS Operating System  The private asymmetrical  key and a  gt  Certificate for 
8. tected  during the initialization  The   LED displays the data traffic on the network  The  II LED displays key exchanges and faults in the equipment management  If a  problem occurs during operation  it will be recorded in the log file and LED III  will turn to    red        LED On  Green LineCrypt ready for operation  Orange LineCrypt not ready for operation  Flashing orange  1x Authorization file configuration missing  2 Internal error detected during self test  LED    Off no traffic  Flashing red encrypted transmission  Flashing green unencrypted transmission    Operation       LED Il  Off  Orange  Red    LED Ill  Red    no key exchange  key exchange in progress  key exchange failed    problem was recorded in the log file   Reading out the log file with the  configuration software will turn off this LED    Next to each of the ehternet sockets two multicolor LEDs labeled  Speed  and       Lnk Act  are located    Speed  Off  Orange  Green    Lnk Akt  Off  Green  Flashing green    no ethernet connection link  10 Mbit  100 Mbit    no ethernet connection link  ethernet link active    ethernet link data active transmission in  progress    LineCrypt s only operating control is the reset push button at the front panel  It  the device serves to restart the LineCrypt  On restart all active  links connections are disconnected  The configuration will be retained     Technical Data             Technical Data  Power supply 110 to 230 V   Power consumption Max  15 VA       Environmental
9. tion cable with RJ45 plug   1 Serial PC cable with mini DIN 8 plug   1 CDROM with LineCryptConfig software for Windows  95 98 ME NT 2000 XP and operating instructions    Installation       Connect the cable to the LineCrypt according to the connection scheme     110    230 V                               100BaseT  extern       100BaseT  intern          Router    Figure 2  Connection scheme  LineCryot L100    Plug the connection to your internal network into the socket marked Intern   The connection to InternetGateway is made via the socket marked Extern  As  the pin assignment of the Ethernet socket corresponds to the pin assignment  of a network card  the following applies for the cable to be used     e Use a crossed cable when connecting to a network card  e g  PC    e Use an uncrossed cable when connecting to a hub or an Ethernet switch                                Contact Line  Transmission lines  LineCrypt  1 2 transmits   HA 3 Not used  1 8 4 5 Reception lines  LineCrypt receives   6 7 8 Not used       Table 1  Allocation of the R  45 plug    If you wish to manage the LineCrypt L100 locally  plug the PC cable into the  mini DIN 8 socket          P    for the local management     Installation       Extern Intern B     O Speed O Speed  OLnk Act OLnk Act    Figure 3  Overview of sockets    If the authorizations are based on the certificate number  your communications  partner requires this number  You can read it with the help of a PC and the  configuration software from
10. you can pull  out the mains plug without delay when required     Power failure    The configuration remains unchanged in case of a power failure  The  LineCrypt L100 is not provided with an emergency operation  In the event of a  power failure you cannot communicate via the LineCrypt L100    wo    Function Overview       Function Overview    The T TeleSec LineCrypt L100 provides protected data transfer via networks  that uses the IP protocol     The LineCrypt L100 acts as a link between a protected internal network and an  unprotected external network  The LineCrypt L100 is based on IP  communication  That means  All other protocols  IPX for example  are not  forwarded between internal and external sides by LineCrypt L100     LineCrypt L100 transfers the encrypted data through an IP Tunnel  In this way   two or more LineCrypt in an unprotected network allow a protected Virtual  Private Network  VPN  to be set up     The LineCrypt L100 can set up IP tunnels to LineCrypt DSL  L  L100 and  SOHO  The option of unencrypted connections with other IP equipment can  also be configured     The current software version 1 0 0 does not support IKE authentication and  the RIP protocol                                     O       O                Figure 1  LineCryot protecting your network    Installation       Installation    Included in delivery    Open the packaging and check that the contents is complete     1 LineCrypt L100 with mains cable and integrated Chip cards   1 Ethernet connec
    