Home
PT-18-PCH-A-11.qxd_Page 1 - Northern Tool + Equipment
Contents
1. DO NOT modify this heater or operate a heater that has been modified from it s original state Modifying this heater will void your warranty Keep children and animals away from heater Always set heater on a stable level surface and use the caster locks to prevent movement of the heater NEVER use heater in occupied dwellings without proper ventilation Operate in a manner that heater will not be exposed directly to rain or dripping water Keep heater area free from combustible materials such as gasoline paint thinners and other flammable vapors and liquids Dust is combustible Do not use heater in areas of high dust concentration ALWAYS maintain proper distance from combustibles Minimum clearance from Combustibles TOP SIDES FRONT 24 12 12 This is an unvented portable heater It A CAUTION uses air oxygen from the area which it is used Ample combustion and ventilation air must be provided See VENTILATION page 4 WARNING This heater is not intended for residential use Page 2 Pinnacle Products International Inc Propane Cabinet Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED TO A FUEL SOURCE PROTEMP Propane Cabinet Heaters Safety Information continued NEVER leave heater unattended Use heater in accordance with all local codes and with CSA 5 90 U S 5th Ed Infrared Patio Heater In the absence of local codes refer to
2. failures or operating difficulties due to normal wear and tear accident abuse misuse alteration misapplication improper installation or improper main tenance and service by you or any third party Failure to perform normal and routine maintenance on the heater shipping damage damage related to insects birds or animals of any kind and damage due to weather conditions are also not covered In addi tion the Limited Warranty does not cover damage to the finish such as scratches dents discoloration rust or other weather damage after purchase All transportation costs for the return of the damaged product or parts will be the responsibility of the purchaser Upon receipt of damaged item Pinnacle Products International Inc will exam ine the item and determine if defective Pinnacle Products International Inc will repair or replace and return the item freight pre paid If Pinnacle Products International Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclaims all warranties for products that are purchased from sellers other than author ized retailers or distributors AFTER THE PERIOD OF THE ONE 1 YEAR LIMITED WAR RANTY EXPIRES Pinnacle Products International Inc DIS CLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WAR
3. Model Date of Purchase Serial
4. RANTIES OF MER CHANTABILITY AND FITNESS FOR A PARTICULAR APPLICA TION FURTHER Pinnacle Products International Inc SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL INDIRECT PUNITIVE INCI DENTAL OR CONSEQUENTIAL DAMAGES Pinnacle Products International Inc assumes no responsibility for any defects caused by third parties This Limited Warranty gives the purchaser specific legal rights a purchaser may have other rights depending upon where he or she lives Some states do not allow the exclusion or limitation of special incidental or consequential damages or limitations on how long a warranty lasts so the above exclusion and limitations may not apply to you Pinnacle Products International Inc does not authorize any person or company to assume for it any other obligation or liabili ty in connection with the sale installation use removal return or replacement of its equipment and no such representations are binding on Pinnacle Products International Inc Always be sure to specify model number and serial number when making any claim with Pinnacle Products International Inc For your convenience use the space provided below to list this information Model Serial Date of Purchase ALWAYS BE SURE TO SPECIFY MODEL NUMBER AND SERIAL NUMBER WHEN MAKING ANY CLAIM WITH PINNACLE PRODUCTS INTERNATIONAL INC FOR YOUR CONVENIENCE USE THE SPACE PROVIDED BELOW TO LIST THIS INFORMATION
5. User s Manual and Propane PINNACLE Operating Instructions Cabinet Heaters PROTEMP Model PT 18 PCH A es ea were etme EEIT TT raras vee i To Crs PP a oe Oe f oan Fie A GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM THE HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRIC SHOCK Fi aaa Fed g gay Of thee Table of Contents ONLY PERSONS WHO CAN UNDERSTAND Se ona inc teenie saci E E gee dase E E ET AND FOLLOW THE INSTRUCTIONS en par pply TMON MAU OM ye csnaarcccdievenewncccsedesneanecceastonns SHOULD USE OR SERVICE THIS HEATER SCKING For LEAKS wi sasiesenicacinensacesswennedesiivanedadeanderdederidans 3 Pied E eimer AEE E E E E P IF YOU NEED ASSISTANCE OR HEATER an EA D E E EET i INFORMATION SUCH AS AN INSTRUCTION Aena E a eGuide E MANUAL LABELS ETCETERA CONTACT Lighting Test Firing and Shutdown Instructions 5 THE MANUFAC TURER Maintenance and Storage IMPORTANT Read and understand all of the TroubleShooting coeeseneaseneaseneesentesensacensasentetensasentesens directions in this manual before assembling starting or Replacement PANS MANS ls csotuncunaanncaspenvecenteine easanpitanenaseegens servicing the heater Improper use of this heater can Explod d Parts Drawing iccecssscnscaseseca
6. ad Wie 50 020 0210 WARNING This heater is not intended for residential use Pinnacle Products International Inc Propane Cabinet Heater User s Manual Page 7 NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED TO A FUEL SOURCE PROTEMP Propane Cabinet Heaters Pinnacle Products International Inc reserves the right to make any changes in materials specifications prices or design without notice Pinnacle Products International Inc may also discontinue items at any time 1 YEAR LIMITED WARRANTY Pinnacle Products International Inc warrants this product to the original retail purchaser only to be free from defects in mate rial and workmanship for a period of one 1 year from the date of initial purchase This product must be properly installed main tained and operated in accordance with the instructions provided Pinnacle Products International Inc requires reasonable proof of your date of purchase from an authorized retailer or distributor Therefore you should keep your sales slip invoice or cancelled check from the original purchase This Limited Warranty shall be limited to the repair or replacement of parts which prove defec tive under normal use and service within the warranty period and which Pinnacle Products International Inc shall determine at its reasonable discretion This warranty does not apply to products purchased for rental use This Limited Warranty does not cover any
7. as 3 temperature ratings high ese medium s and low s The Valve Knob is located conveniently at the top of the heater for easy access and control Checking for Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If bubbles appear there is a leak If a leak is found turn off the gas supply re make the leaking connection If the leak persists after several tries contact Pinnacle Customer Service at 215 891 8460 The installation of this heater must meet all local codes and or gas utility requirements In the absence of local codes the National Fuel Code ANSI 2223 1 should be followed The minimum clearances to any combustible construction materials must be maintained at all times see Page 2 WARNING This heater is not intended for residential use Pinnacle Products International Inc Propane Cabinet Heater User s Manual Page 3 NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED PROTEMP Propane Cabinet Heaters TO A FUEL SOURCE Features piezo Valve Knob Handle Slot Back Cover Safety Guard Rear Front Castor Castor Figure 1 Product Features Unpacking and Assembl Remove heater and base from Carton Save carton and packing materials for later storage Remove all protective packaging protecting heater during shipping Place Heater Base on flat surface with whee
8. ay result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not attempt to light heater Extinguish any open flame Shut off gas to heater If odor continues contact your local gas supplier or fire department Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can not reach your gas supplier call the fire department Service must be done by a qualified service agency or the gas supplier Ke not operate this heater until you AWARNING have read and thoroughly understand these safety and operating instructions Only persons who can read and understand these instructions should use or service this heater Do not direct heater discharge towards another LP cylinder unless it is at least 20 feet from the heater California Residents Combustion by products produced when using this product contain carbon monoxide a chemical known to the state of California to cause cancer and birth defects or other reproductive harm Safety Information This heater is designed and approved for use as a con structio
9. cctetanatnitnucseaeecennesoans cause serious injury Keep this manual for future MV ANNAN E E AEE EE reference AWARNING Carbon Monoxide Hazard This heater produces carbon monoxide which has no odor Burning the heater in an enclosed space can kill you Never use the heater in enclosed spaces such as a tent a camper any vehicle or recreational vehicle RV enclosed shelter or any other enclosed areas ADANGER Not for use in residential living areas or in non adequately ventilated enclosed spaces Never bring or store a propane cylinder indoors CONSUMER Retain this manual for future reference Pinnacle Products International Inc 668 Stony Hill Road 302 Yardley PA 19067 USA Phone 215 891 8460 Fax 215 891 8461 Web www pinnacleint com Email info pinnacleint com 500250322 14 NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED TO A FUEL SOURCE PROTEMP Propane Cabinet Heaters FIRE BURN INHALATION AND AWARNING EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUC TIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNERS DUST PARTICLES OR UNKNOWN CHEMICALS NOT FOR HOME OR A WARNING RECREATIONAL USE If the information in this manual is not A WARNING followed exactly a fire or explosion m
10. d Positioning the Heater There is a brake in each of the front wheels of your heater that helps keep it in place when in use To engage the brakes push the lever down on each wheel To move the heater release the brakes simply by flipping the levers on both brakes up See Figure 5 Figure 5 Casters and Brakes WARNING This heater is not intended for residential use Pinnacle Products International Inc Propane Cabinet Heater User s Manual Page 5 NEVER LEAVE HEATER ae Propane ING OR WHILE CONNECTED PROTEMP 4 TO A FUEL SOURCE Cabinet Heaters Maintenance Storage Be sure to inspect the heater before each use to look for Always disconnect the LP cylinder from the regulator any such obstructions Be sure to keep the air l assembly and remove the LP cylinder from the heater passage ways burner and combustion areas clean Wipe before putting the heater into storage If for any reason the With a damp cloth or use a vacuum cleaner to clean these heater is to be stored indoors the heater MUST be areas It is suggested that you perform a thorough clean disconnected from the LP cylinder and the cylinder stored ing at least once every 30 days of operation You may outdoors in a well ventilated area out of the reach of need to clean the heater more often if conditions are children and in accordance with the Standard for Storage naturally dirty and Handling of Liquefied Gases ANSI NFPA 58 latest Clean t
11. e Back Cover by sliding the cover straight up and away from the Heater Body Place the LP cylinder on the Bottom Plate and replace the Back Cover To connect LP cylinder insert regulator end fitting into cylinder valve rotate coupling nut clockwise and tighten firmly see Figure 3 Open valve on propane cylinder slowly If the valve is not opened slowly the excess flow check valve in the regulator will stop the flow of gas If this should hap pen close the valve wait one minute or until you hear the valve click and re open slowly Regulator LP Cylinder Valve Coupling Nut Figure 3 Connecting Hose Regulator to LP cylinder WARNING This heater is not intended for residential use Page 4 Pinnacle Products International Inc Propane Cabinet Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED TO A FUEL SOURCE PROTEMP Propane Cabinet Heaters Connecting to Gas Supply Continued Be sure to inspect all connections for leaks by using a 50 50 mixture of dish soap and water on all connection Any bubbles forming indicate a leak Lighting Instructions 1 Turn the knob on the LP cylinder valve counterclockwise to the ON position 2 Turn the Valve Knob on heater to the OFF position 3 Wait five 5 minutes for any gas to clear Smell for gas If none is evident proceed to the next step 4 Push in the valve knob and turn to PILOT NOTE If
12. erwise clean the pilot orifice Dirt in pilot orifice Close LP cylinder valve Wait one minute for Safety switch in cylinder valve switch to click off Reopen LP cylinder valve engaged slowly Tipover switch engaged Move heater to a level surface No spark is created when Incorrect igniter electrode position 1 Properly position electrode ignited Electrode damaged or broken Replace the electrode Loose or disconnected igniter wire 3 Tighten or reconnect loose wire Broken igniter wire Replace igniter wire Heater stops running by Thermocouple damaged Replace thermocouple itself Gas control valve damaged Replace gas control valve Gas leak Check all connections for leaks using 50 50 solu tion of dishsoap and water Repair any leaks found Thermocouple not in contact with 4 Clean inside of heater housing pilot flame Tip over switch damaged or loose 5 Inspect tip over switch and connections Replace if connection at tipswitch necessary Out of fuel 6 Replace LP cylinder WARNING This heater is not intended for residential use Page 6 Pinnacle Products International Inc Propane Cabinet Heater User s Manual NEVER LEAVE HEATER 3 Propane ee PROTEMP i TO A FUEL SOURCE Cabinet Heaters Exploded View Replacement Parts List ene Part Description Part Number Plesu Part Description Part Number 6 Heat Piate 50 0020205 8 Manual Valve Assembly _50 013 0160 o MPU Le
13. gulator supplied Never use any other hose and regulator Do not subject the cylinder to excessive heat LP Characteristics Flammable explosive under pressure heavier than air and pools in low areas In its natural state propane has no odor but for safety an odorant that smells like rotten cabbage is added Heater is manufactured for use with LP gas only DO NOT attempt to convert to any other gas Such modifications are dangerous and will void your warranty When heater is not in use LP supply must be shut OFF Contact of LP gas with the skin can cause freeze burns The amount of LP gas used by this heater varies The two factors that will determine this are as follows 1 The amount of gas in the LP cylinder 2 The temperature of the LP cylinder and surrounding area Product Features Piezo Ignition Model PT 18 PCH A uses a manual Piezo igniter button to send a spark when you turn the Gas Valve Knob to PILOT The spark ignites the fuel at the pilot Tip Switch Shut Off System The heater is protected by a system whereby the heater shuts off if it is substantially tilted in any direction ODS Oxygen Depletion Sensor This heater uses an Oxygen Depletion Sensor ODS to monitor the oxygen content in the heated space Should the oxygen level fall below 18 the flame will no longer touch the thermocouple stopping electrical current and the heater will shut off Adjustable Input Ratings The heater h
14. he Ceramic Plaques using compressed air below edition The plastic valve plug or valve cover supplied 30 PSI to prevent damage to plaques with the LP cylinder must be reinstalled on the valve to l a protect the fitting from damage A yellow tip of the pilot flame indicates that the burner area NOTE Repair of this heater should be done by a may be in need of cleaning qualified service person It is recommended that you save all of the packaging AWARNING Never store an LP cylinder inside of a materials that came with your heater and re package the Ibuilding or near any other gas or oil heater using these materials for safe storage burning appliances Debris dust and dirt inside of the heater body can affect ACAUTION Always be sure that the heater has the performance of your heater This debris can impair the been allowed to cool for at least 30 heaters ability to draw air for ventilation and combustion minutes before attempting to store service or Spiderwebs can also appear during periods of inactivity perform maintenance Troubleshooting Guide Possible Cause Burner does not light Air in gas line 1 Keep depressing the gas control knob for at least 30 seconds to remove any air in line Gas pressure from cylinder too low 2 Check LP cylinder pressure Tank may be empty Open LP cylinder valve LP cylinder valve turned off Inspect and clean heater housing Obstruction in air passageway Blow out or oth
15. ls on ground Line up holes in bottom of heater cabinet with locking tabs on top of base see Figure 2 Mount heater cabinet to heater base sliding tabs through holes in bottom of cabinet and sliding cabinet backward approximately or until cabinet will not move further back Use thumbscrews to attached heater cabinet to heater base Inspect heater closely for any damage that may have A Figure 2 Attaching Heater to Base occurred during shipping If there is any damage return the heater to the place of purchase Ventilation Caution Always provide a fresh air opening in the heated space of at least three square feet 2 800 sq cm for each 100 000 BTU Hr of heater output Provide a larger opening if more heaters are being used FOR OUTDOOR USE INDOOR USE PERMITTED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Connecting to Gas Supply The Propane LP gas pressure A CAUTION regulator and hose assembly sup plied with the heater must be used without alteration Be sure to inspect the regulator hose A CAUTION before each use If the hose is cut or frayed replace it with the manufacturer suggested assembly IMPORTANT Always use a propane LP cylinder that has a connection device that is compatible with the hose and regulator assembly supplied Remove th
16. n heater in accordance with ANSI Z83 7 2011 CSA 2 14 2011 Other standards determine the use of fuel gases and heat producing products for specific uses Check with your local fire safety authority if you have questions about applications This infrared heater s intended use is primarily for the temporary heating of buildings under construction alteration or repair Infrared fired means that all of the combustion products enter the heated space This heater is rated at 98 combustion efficiency but still produces small amounts of carbon monoxide Carbon monoxide is toxic Humans can tolerate small amounts of carbon monoxide and caution should be taken to provide adequate ventilation Failure to provide adequate ventilation in accordance with this manual could result in death Early signs of carbon monoxide poisoning resemble the flu The symptoms of inadequate ventilation are headache dizziness burning of the nose and eyes nausea dry mouth sore throat If the heater is being used in the presence of others be sure to inform them of the proper safety precautions operating procedures and the hazards involved Some people are more affected by carbon monoxide than others These are pregnant women people with heart or lung disease or anemia those under the influence of alcohol or at high attitudes Use 20 Ib LP cylinders only Check the heater thoroughly for damage before each use DO NOT operate a damaged heater
17. the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural Gas and Propane Installation Code CSA B149 1 This heater is not for use on finished floors Propane Supply Information You must provide the propane gas and cylinder s Use this heater only with a propane vapor withdrawal supply system Refer to Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas ANSI NFPA 58 Your local library or fire department will have this booklet The cylinder must be equipped with a collar to protect the gas valve an arrangement of vapor withdrawal a shutoff valve terminating the cylinder valve outlet as specified in the American National Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections and a safety relief valve in direct contact with the vapor space of the tank Always keep the cylinder in an upright position Avoid knocking the cylinder over on its side with the hose regulator connected as this can cause damage to the regulator diaphragm Never store a propane LP cylinder indoors or in the vicinity of any gas burning appliances Protect the cylinder valve and handle it with care Be sure that the shut off valve is closed tightly after each use Be sure to protect the POL fitting from damage when disconnected Damage to this fitting can lead to leaks Never connect an unregulated cylinder to the heater Always use the hose and re
18. this is first time use for heater or LP cylinder has been replaced hold the valve knob for approximately 30 seconds to allow bleeding of air from system then turn valve knob to PILOT Medium 1 i jj it i I 1 i a Peete cet ee eee i Figure 4 Gas Valve Knob Position Burner Pattern 5 While depressing the valve knob press red piezo ignition button to ignite It may be necessary to press the ignitor button several times to ignite the center burner panel 6 Continue to hold valve knob down for 30 seconds after the panel has lit This will heat the thermocouple After 30 seconds release the valve knob 7 lf heater fails to light or does not stay lit repeat Steps 2 through 6 8 When the center burner panel stays lit turn valve knob to desired setting Test Firing Heater It is always a good idea to test fire your heater in a safe and controlled environment in an area with adequate ventilation and away from any combustibles to be sure that all functions of the heater and gas supply system are operating properly Leak test all gas connections with a 50 50 solution of dish soap and water DO NOT use a flame to test for leaks Shutdown Instructions 1 Turn the Valve Knob to the OFF position 2 Turn the knob at the LP cylinder clockwise to the OFF position 3 Disconnect Regulator Hose assembly from the LP cylinder Moving an