Home
7x15W 5in1 LED Slim Par Light User Manual
Contents
1. Slave operation one unit will act as the controlling unit and the others will react to the controlling units built in programs Any unit can act as a Master or as a Slave however only one unit can be programmed to act as the Master Master Slave Connections and Settings 1 Daisy chain your units via the XLR connector on the rear of the unit Use standard XLR microphone cables to link your units to gether Remember that the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only 2 Using the Master unit choose your desired mode or program and connect the Slave unit or units 3 Set the Slave unit s to the DMX address mode They will now follow the Master unit DMX MODE Operating through a DMX controller give the user the freedom to create their own programs tailored to their own individual needs 1 This function will allow you to control each individual fixture s traits with a standard DMX 512 controller 2 To run your fixture in DMX mode plug in the fixture via the XLR connections to any standard DMX controller Press MODE button till DMX MODE display and press SET UP button to enter the DMX address and DMX mode selection and then press UP or DOWN buttons to adjust the DMX address and DMX mode The channels value refers to the following channe
2. order lt ENTER gt D locate the function of which you want to change the value Press the MODE button you can browse all the function such as AUTO RUN DMX MODE SLAVE MODE SOUND While the function you want for example if DMX MODE the ADDR amp MODE can be adjusted You can press SETUP button to catch them if MODE it has 6 models press UP amp DOWN to locate it Program Mode amp Sound Mode In Program Mode you can pick your desired factory installed program static color color show color fade or color cycle You can apply a strobe effect to static colors and control the speed of the color shows color fade and color cycle 1 Plug the fixture in and press the MODE button till 01 static display you are now in program model Press UP and DOWN to find your desired effect 2 If you have selected a static color press SET UP button to enter into the flash rate F 000 100 press UP and DOWN to adjust and select your desired flash rate 3 When you have chosen a color show 02 17 press SET UP button the display will show S000 S100 Press UP and DOWN button to adjust and set the speed When the display shows F000 F100 your desired program is running in strobe effect 4 When the display shows Sound the unit is working in sound active mode and the sensitivity SENS 00 99 is adjustable Master Slave Operation This function will allows you to link units together to run in a Master Slave mode In Master
3. the unlikely event your unit may require service please contact us Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth every 20 days 3 Always be sure to dry all parts completely before plugging the unit back in Cleaning frequency depends on the environment in which the fixture operates i e smoke fog residue dust dew LED PAR LIGHT Features Voltage AC90V 245 V 50 60Hz Power 120W Color of LED Red amp Green amp Blue amp Amber amp White Lamp 7pcs 15W LEDs Each LED have RGBWA colors Beam angle 40 degree Life time more than 100 thousand hours Color effect RGBWA mixing Function Effect dimmer strobe eotic gradual change sound activeted Cooling mode Natural Convection Flicker free for television and film Color RGBA color can be mixed to more than 16 7million kinds of color Control DMX512 Master slave stand alone music Activate Channel 9CH DMX signal Input Output 3 pin XLR Feature Cast Aluminum case nice and wide application less power consumption high brightness stable performance long life Function Color combination changer of the latest hybrid technology and excellent built in program strobe gradual pulse cycle color selection music activ
4. 7X15W 5 in 1 LED Flat Par Light User Instruction CONTENTS 1 INSTRUCTION Unpacking Introduction AC Power Safety Instruction Cleaning FEATURE SET UP 3 Pin to 5 Pin Conversion Chart Setting up a DMX Serial Data Link Master Slave Fixture Linking OPERATING INSTRUCTIONS Operating modes Product overview Program Mode amp Sound Mode Master Slave Operation Master Slave Connections and Settings DMX Mode DMX CHANNEL SUMMARY LED PAR LIGHT Introduction Unpacking Thank you for purchasing our products Every unit has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact In the case damage has been found or parts are missing Save the carton and all packing materials In the event a fixture must be returned to the factory It is important that the fixture be returned in the original factory box and packing Introduction The unit is a DMX intelligent LED par can This light can be used in a stand alone mode or connected in a Master Slave configuration The unit can also be controlled via DMX controller This light has four operating modes Sound Active mode stand alone mode Master Slave and DMX control mode AC Power This fixture has an auto s
5. ated electronic linear Dimmer Size 290x160x270mm N W 2 0KG GW 2 5KG Packaging 640x340x290mm 4pcs CTN LED PAR LIGHT Set Up Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior Figure COMMON DMX512 OUT DMX512 IN 3 PIN XLR DMX 3 PIN XLR f XLR Male Socket XLR Female Socket 1 Ground 2 Cold 2 Colg 1 Ground z Cr Figure 2 3 Hot 3 Hot Figure 3 XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive 3 Pin to 5 Pin Conversion Chart Note If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter The chart below details a proper cable conversion 3 Pin to 5 Pin Conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 Data signal Pin 2 Pin 2 Data signal Pin 3 Pin 3 Not Used Do not use Not Used Do not use Setting up a DMX Serial Data Link Universal DMX Controller 1 Connect the male 3 pin connector side of the of the controller 2 Connect the end of the cable coming from the to the input connector of the ne
6. fast 0 50 DMX 8 channels control 51 100 jump change CH 3 Function Choose 101 150 gradual change 151 200 pulse change 201 255 Sound active CH 4 Speed Function Speed slow fast CH 5 Red R dimmer linear dark bright CH 6 Green Gdimmer linear dark bright CH 7 Blue B dimmer linear dark bright CH 8 White W dimmer linear dark bright CH 9 Amber Adimmer linear dark bright KEY POINT Easy to operate friendly design no flicker while dimmer stable quality Applicable to photograph camera and TV station as well 10
7. l summary LED PAR LIGHT DMX Channels Summary 1 DIAGRAM E Digital Display S O QQ A Function B Up C Down D Enter A B C D HOW TO OPERATE Press button A there will be eight different effects The fist two numeric stands for functions refer to Diagram II The last two numeric stands for DMX address or speed You can modify it with B or C button D button is to confirm while you settled 2 LED Display function cross references D button is to confirm while you settled N Display Function 1 D0001 8CHs Address Code 001 512 Change the address code by B or C button 2 CC00 8Colors Changing 01 99 Color change fast by B or C button 3 CPOO 8colors gradual change 01 99 Speed of gradual changing by B or C button 4 DE00 8 Colors mixed changing 01 99 Select color While change color with B or C button 5 BEBE Music activate 6 R220 Red color Changing 000 255 Change the color by B or C button 7 G220 Green color Changing 000 255 Change the color by B or C button 8 B220 Blue color Changing 000 255 Change the color by B or C button 9 W220 White color changing 000 255 Change the color bu B or C button 10 A220 Amber color changing 000 255 Change the color bu B or C button 3 DMX512 Channels Ka Function Details CH 1 Dimmer R G B W dimmer linear dark bright CH 2 Strobe R G B W strobe slow
8. n an area that will allow proper ventilation Allow about 6 15cm between this device and a wall e Do not attempt to operate this unit if it becomes damaged e This unit is intended for indoor use only use of this product out doors voids all warranties e During long periods of non use disconnect the unit s main power e Always mount this unit in safe and stable matter e Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to the point they exit from the unit e Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 3 for cleaning details e Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat e The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance Warning To prevent or reduce the rist of electrical shock or fire do not expose this unit to rain or moisture Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufacturers warranty In
9. witching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 90V and 240V AC All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit Even if the rheostat or dimmer channel is used solely for a 0 100 switch Safety Instructions Please read these instructions carefully which includes important information about the installation usage and maintenance of this product e To reduce the risk of electrical shock or fire do not expose this unit rain or moisture e Do not spill water or other liquids into or on to your unit e Be sure that the local power outlet match that of the required volt age for your unit e Do not attempt to operate this unit if the power cord has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short e Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user serviceable parts inside e Never operate this unit when it s cover is removed e Never plug this unit in to a dimmer pack Always be sure to mount this unit i
10. xt fixture consis 3 Then proceed to connect from the output as s so On Master Slave Fixture Linking 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on Operating Modes You can use the unit in either a stand alone mode or a master slave configuration there are 4 modes to choose from e Program Mode Choose a static color color show color fade show or color cycle The speed of the show is adjustable You can also have the unit strobe in this mode e Master Slave Mode Using the Master unit choose your desired mode or program and connect the Slave unit or units All slaves will now follow the Master unit But only one master e DMX control mode This function will allow you to control each individual fixtures traits with a standard DMX 512 controller Product overview Diagram I DO QQ A B C D Button Function lt FN gt A Used to access the mode or to return to a previous mode option lt UP gt B Change the value of function you choosing in ascending order lt DOWN gt C Change the value of function you choosing in descending
Download Pdf Manuals
Related Search
Related Contents
Manuel d`instructions FR GE 2.4 GHZ CORDLESS 27831 User's Manual Weider WESY3906 User's Manual Panasonic TX-L42D25B LCD TV Samsung SBD-815/M User Manual LV02675B, LV02675BF, LV0265H, LV0265HF Ton Miles Calculator User Manual Copyright © All rights reserved.
Failed to retrieve file