Home

keyEyesHDi user manual

image

Contents

1. Isolated Relay closure Relay activated when Take key is OFF Tally Out Key Off Air Not Used Not Used o O Not Used General Purpose Input 1 GPI1 Pull to Ground to activate 6 Be 9 DI eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Take key ON Only momentary contact required gt 50mS If GPI Style set to Momentary Pulled to ground Take key ON If GPI Style set to Latched Open Take key OFF If GPI Style set to Latched General Purpose Input 2 GPI2 Pull to Ground to activate Take key OFF Only momentary contact required gt 50mS If GPI Style set to Momentary Not Used Pe eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 5 3 Appendix 4 technical specification 1485Mbit 750hm equalisation HD SDI Outputs 2 output HD SDI 1485Mbit 750hm 800mV GPI Inputs 2 GPl s activate by short to Take Key On ground Take Key Off Tally Outputs 2 GPO s Key is On Key is Off eyeheight I Bus 2 wire network connections Control Surfaces Option of 2 eyeheight control surfaces Integral front mounted contol panel or remote FP 9 flexipanel Chassis Eyeheight evoluti
2. yesHDi The keyEyesHDi is controlled using a set of MENUS Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the keyEyesHDi See chapter 4 Control Panel Operation for details of the control panel operation See section 3 of this chapter for the full list of menus 4 2 Automation Control of the key amp yesHDi Automation of the evolutionDT products is achieved either via the RS232 port currently not implemented or via the I Bus Port using an optional DG 9 RS232 to I Bus dongle Automation control of the kKey yesHDi is performed using the geNETics Automation Protocol Genetics protocol is described in detail in the geNETics User Guide section titled Automation Protocol on the geNETics Platform The menu list in section 3 of this chapter contains the data information for the protocol Please refer to the User guide for the DG 9 eyeheight dongle and set up software 4 3 Operational Menus for the key yesHDi Menus 00 03 Top Level Menus Menu Num Heading Automation Function 0 00 PLAY none GoTothemain Play menus 4 7 01 SETUP none Go To the main Set up menus 84 87 02 MEMS none Go To the Memory menus 16 47 03 UTIL none Go To the main Utility menus 108 111 8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 285553
3. All video connections are HD SDI Figure 1 Typical Connections 2 2 Applications for keyEyesHDi Applications for keyEyesHDi include the following e Down Stream and Up Stream keyers in transmission systems e Offline Captioning e Presentation and Master Control systems Eyeheight PresTX e Bug Keying keyEyesHDi will be used in a situation where a device such as a caption generator is required to overlay captions onto a video background 2 3 Associated Equipment for the key amp yesHDi The key yesHDi in the evolutionDT platform is fully self contained The evolutionDT can optionally be rack mounted in with 1 or 2 units in a 19 rack using the optional FF 6 rack mounting This is a factory installed option and should be ordered with the product Rack mounted units should be supported with suitable chassis supports 5 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 Control Panel Figure 2 shows the control panel of the evolutionDT platform 1 Power Status LED Green Normal operation Green Flashing Version Information Display Orange Product is initialising Flashing Red Product is in Field Reprogramming Mode 2 Menu Display Button 1 of 4 Displays Menu Information The colour of the menu button indicates the function Green adjustment menu Pr
4. 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 56 59 Utility Menus For Automation use only Menu Num Heading Automation Function Ee GCR ON Ee Ee _ 59 BACK none Go To tthe Top Level Menus Menus 84 87 Keyer set up menus Menu Num Heading Automation Function 84 Transition none Go To the main Trans menus 92 95 85 Clip and none Go To the main clip menus 96 99 gain 86 Styles none Go To the styles menus 104 107 87 Back none Go To the main top menus 0 3 Menus 92 95 Key transition menus I6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu Heading Menu Options Function m Transition a This changes the type of transition type seit which is the way in which the keyed SUP in source appears Transition a This changes the speed of the medium age Speed 2 slow transition 3 user 94 More This takes you to menus 88991 which further configure the mixer transitions 95 Back This takes you back to menus 84 87 Menus 88 91 more key transition menus Menu Heading Menu Options Function Wipe a This changes the type of wipe pattern 2 vertical curtain pattern when wipe is selected as the 3 horizontal curtain key transition 4 diagonal wipe i 5 diamond wipe 6 horizontal arrow 7 vertical
5. Menu Num Heading Automation Function 108 SYSTEM none Go To the System menus 36 39 109 SOFTWARE none Go To the Software menus 44 47 Loo l SA 111 Back This takes you back to the Top Level menus 0 3 20 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 5 Technical Appendix 5 1 Jumper Links on the GPI 1 0 Jumper Function J31 Set to Top Polarity selection for GPI Relay Output 1 J32 Set to Top Polarity selection for GPI Relay Output 2 J33 Set to Top Polarity selection for GPI Relay Output 3 J34 Set to Top Polarity selection for GPI Relay Output 4 Jumpers LK1 gt 4 set the polarity of the relay Pin 1 3 Relay active Contact a Relay inactive Contact b Figure 3 Diagram of GPI Output GPI1 4 5 2 Rear 2SW D Type Pinout General Purpose Output Switch 1 contact a GPO1a Isolated Relay closure Relay activated when Take key is ON Tally Out Key On Air General Purpose Output Switch 1 contact b GPO1b Isolated Relay closure Relay activated when Take key is ON Tally Out Key On Air 3 General Purpose Output Switch 2 contact a GPO2a Isolated Relay closure Relay activated when Take key is OFF Tally Out Key Off Air General Purpose Output Switch 2 contact b GPO2b
6. Menus 36 39 Key timing menus Menu Num Heading Automation Function L 3s E 37 Timing 0 2048 This changes the system delay through the unit The default is 1 2 of a video line 14 8uS 1100 pixels The user can make this smaller or larger If the delay is made smaller the system delay becomes smaller but also the synchronising range becomes smaller This becomes a compromise between synchronising range and delay 38 GPI en Controls the operation of GPI1 and 2 Style u Latched Take action is toggled ON and OFF when GPI1 is toggled ON and OFF Momentary When GPI1 is toggled ON Take is set to ON when GPI2 is toggled ON Take is set to OFF 39 BACK none Go To the Top Level Menus B eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 40 43 Preview safe area generator For Automation use only Automation None Menu Num Heading 40 SAFE ACTION 41 None Menu Level A 0 S Action 1 S Capt 2 DigEdge 3 An Edge Menu Level B 0 4 3 1 16 9 2 16p4 3 3 16p149 4 43p16 9 Menu Level C 0 Thin 1 Thick 2 Shade 3 Black 0 EDH Off 1 EDH On none 42 PGM 43 BACK Menus 44 47 Software version menu Function This Switches on and off the currently selected area Pressing the Red switch next to this one and adjustin
7. to the next device in the device list In setup mode this button will pick up a free device and assign it to this panels device list The button will flash to indicate that a free device is selected 8 Previous Device Button 6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Where more than one device is assigned to the panel the prev dev will move control to the previous device in the device list In setup mode this button will remove a device owned by this panel from this panels device list The button will flash to indicate an owned device is selected 9 Info Button This button displays all hardware software and firmware version information for the currently selected product and this panel In setup mode where a free evolutionDT device is selected this button will flash indicating that the network address box amp slot can be changed Pressing this button will take you to the adjustment menus 10 Setup Button Press and hold this button for four seconds to enter setup mode Figure 2 evolutionDT Control Panel miy x eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 Operation 4 1 Manual control of the key
8. 5 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 04 07 PLAY Menus Menu Num Heading Automation Function 04 TAKE 1 take off This Causes the Auto Transition to 2 take on occur The On Off state is also indicated in the window 05 TIME 1 200 This is the Key Transition time The time taken for the key to fade on or off in auto transition mode oo m 07 BACK none Go To the Top Level Menus Menus 08 11 System set up menus For Automation use only Menu Num Heading Automation Function 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 12 15 System set up menus For Automation use only Menu Num Heading Automation Function 12 BGiPOS In 2 When this button is pressed to Default 7 Green the window indicates shows ee two options which can be changed 0 15 by adjusting the two rotary digipots A Default 7 and B Digipot A moves the position of the background picture relative to the key and the foreground Digipot B moves the position of the key relative to the foreground and the background 13 L ee Ta A Press this button and the three H Menu Level B digipots indicated by the lit LED s will S 0 255 H ug Change the Luma Hue and 0 255 S Saturation of the Matte col
9. arrow User an TMG This changes the transition time of Tatton the user setting for menu 93 Time Mask This takes you to the key mask menus 100103 Back This takes you back to menus 9295 7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 100 103 Garbage matte mask menus Menu Heading Menu Options Function Num 100 Garbage Eh This switches on the garbage matte matte 2 Invert The garbage matte allows you to mask configure a box within the picture outside of which NO keying is visible With the invert option no keying is possible INSIDE the box 101 Sides of T He An Pressing this button will make the garbage matte 0 gt 719 three rotary digipots A and B active matte box j garbage matte Digipot A will change the garbage We matte box top edge Digipot B will change the garbage matte box bottom edge 102 Top and age matte Pressing this button will make the bottom of 03575 three rotary digipots A and B active garbage re garbage matte box matte 0575 Digipot A will change the garbage matte box top edge Digipot B will change the garbage matte box bottom edge 103 Back This takes you back to menus 88391 Menus 96 99 Key clip and gain menus I8 eyeheight Unit 34 Park House Watford Business Park Greenhill Cr
10. escent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu Heading Menu Options Function Mu Clip Gain en This adjusts the key gain Clip Lift Ge sl a This adjusts the key lift Buzz sic takes you back io menue takes you back to menus 84387 Menus 104 107 Key style menus Menu Heading Menu Options Function Num 104 Key Style En This switches between keying styles additive R Er a 2 self key Normal is multiplicative keying air Additive keying is used for key sources with an anti aliased fill AND key most character generators Self Key uses the Fill as the Fill AND key source Colour Fill replaces the Fill source with a matte generator Key Invert fea This inverts the key source if invert is selected Colour fill Level A Pressing this button will make the Border Luminance Matte 0 gt 255 three rotary digipots A B and C Level B a ae Border Hue 02255 active Level C nn Digipot A will change the colour fill matte luminance Digipot B will change the colour fill matte hue Digipot C will change the colour fill matte saturation 107 Back This takes you back to menus 84287 19 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 108 111 Util Menus
11. essing the menu or using the associated digipot 6 will adjust the menu value Yellow information menu no adjustment possible Blue navigation menu Pressing the button will take you up or down the menu hierarchy Red multiple variable menu Pressing the button will open the menu assigning one digipot 6 to each variable The active LED 5 will light above the digipots associated with each variable 3 Next Menu Button Within a layer of the menu hierarchy there may be more than four menus and where this is the case the next button will illuminate to show that further menus are available Pressing the next button moves you to the next set of menus 4 Previous Menu Button Within a layer of the menu hierarchy there may be more than four menus and where this is the case the prev button will illuminate to show that previous menus are available Pressing the prev button moves you to the previous set of menus 5 Digipot Active LED 1 of 4 llluminates to indicate that the digipot below is active for adjustment of the associated menu variable 6 Digipot 1 of 4 Allows for rapid adjustment of the associated menu variable Pressing a digipots returns the associated variable to its default value 7 Next Device Button It is possible to control more than one device from a single evolutionDT control panel Where more than one device is assigned to the panel the next dev will move control
12. eyeheight KeyEyesHDi 01 12 05 vl 0O user manual Table of Contents 1 System Overview anne 4 2 Installation 2 50 5 2 1 Connections to a keyEyeSHDi ccceeeeeeeceeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 5 2 2 Applications for keyEyesHDi 424440400unnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 2 3 Associated Equipment for the keyEyesHDi ssessssseeeereeeesssrrrrrrnreessse 5 3 C ntrol Pan l sessar ee 6 4 Operation Reena eee ee ne ere eee eee ee ee eee ere eee ee ene re 8 4 1 Manual control of the keyEyesHDi eee ee cceeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 8 4 2 Automation Control of the keyEyeSHDi cceeeeeeeeeeeeeeeeeeeteeeeeeeees 8 4 3 Operational Menus for the keyEyeSHDi cccceeeeeeeeeeeeeeeeneeeeeees 8 S Technical AppeNd nun kB EI 21 5 1 Jumper Links on the GPI WO 22224444000nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 21 5 2 Rear 25W D Type Pinot nen 21 5 3 Appendix 4 technical specification ccccceeeeeeeeeeeeeeeeeeeeeeeeeeeees 23 2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Table of Figures Figure 1 Typical Connections uuss4444442444nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 Figure 2 evolutionDT Control Panel 24444000snnnnnnnnnnnnnnnn
13. g the rotary digipots with the lighted green LED s chooses the Selected area When this button is pressed to Green The Three line display in the window indicates the three options which can be changed by adjusting the three rotary digipots A B and C Digipot A Determines the basic Function Selects Safe Action option Selects Safe Caption option Selects Digital Edge option Selects the An Edge option Digipot B Determines the Screen Format Standard 4 3 Screen Standard 16 9 Screen 16 9 Shoot to protect 4 3 16 9 Shoot to protect 14 9 4 3 Shoot to protect 16 9 Not available in 525 Digipot C Determines the Style of Indicate Thin White lines are used Thick White lines are used Shade is used for danger area Black is used for danger area Re insert EDH Control Off On Go To the Top Level Menus Menu Num Heading Automation Function 44 info none Information 45 Info none Information 46 none none Software Version Information 47 BACK none Go To the Top Level Menus Menus 48 51 Keyer transition time menus For Automation use only Menu Num Heading Automation Function Menus 52 55 Keyer transition type menus For Automation use only Menu Num Heading Automation i Function l 15 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0
14. n 24 SAVE 1 Save Pressing this will Save Memory MEM13 number 1 25 SAVE 1 Save Pressing this will Save Memory MEM14 number 2 26 SAVE15 1 Save Pressing this will Save Memory MEM3 number 3 27 BACK none Go To the Top Level Menus Il eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 28 31 Save memory 426 menus NEXT PREV to navigate Menu Num Heading Automation Function 28 SAVE 1 Save Pressing this will Save Memory MEM16 number 4 29 SAVE 1 Save Pressing this will Save Memory MEM17 number 5 30 SAVE 1 Save Pressing this will Save Memory MEM18 number 6 31 BACK none Go To the Top Level Menus Menus 32 35 Power on memory menus Menu Num Heading Automation Function 32 Set As 1 Set Pressing this will set the current Pow On system set up as the Power on Memory memory default 33 Recall 1 Recall Pressing this will recall The Power on Pow On memory set up in the last menu Memory 34 Total 1 Reset Pressing this will cause a first Birthday Reset of the unit All current memories and settings will be lost 35 BACK none Go To the Top Level Menus I2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
15. nnnnnnnnnnnnnnnn 7 Figure 3 Diagram of GPI Output GPI1 4 uuuussnsssssnnnnnnnnnnnnnnnnnnnnnnnnnn 21 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com System Overview keyEyes is a Luminance Keyer Unit mostly used for keying captions and graphics These units are commonly used in transmission and post production The main features are as follows e Full 10 Bit luminance Keying e Auto Transition Timed Fade in control e Key Gain and lift controls e Multiplicative Additive Self Key and colour fill modes e Key Mix and 8 Wipe Transitions e Up to 27 6uS user definable synchronisation window for Inputs e Transparent to all embedded signals e Automation controllable e 6user memories e GPI inputs to enable take to A or take to B e Relay outputs to indicate on air status 4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 Installation 2 1 Connections to a key amp yesHDi The diagram below shows the typical connections to the keyEyesHDi REF ouTe N3 ouri GPI T C Aes DBUS RS232 Ni ne IBUS Fill Key SS a E Mains Video Server Char Gen Transmission Pvw Monitor
16. on miniBox chassis Either a half width 1RU assembly for desk mounting or a full 1 RU assembly for 19 inch rack mounting Line Standards 1080 23 98psf 1080 24psf 1080 23 98p 1080 24p 1080 25p 1080 50i 1080 29 97p 1080 30p 1080 59 94i 1080 60i 720p 23 98 720p 24 720p 25 720p 29 97 720p30 720p50 720p59 94 720p60 Power supply 100 gt 240V ac Less than 50W power consumption D3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
17. our 14 KEYING a This changes the keying mode additive 3 2 self key Normal is the default mode ea Additive is selected for an Additive Key mode Self is selected for Self Key mode where the key is derived from the foreground input Colour Fill mode provides an internal Matte Fill 15 BACK pene Go To the Top Level Menus Menus 16 19 Memory 133 menus NEXT to navigate Menu Num Heading Automation Function 16 MEM13 1 Recall Pressing this will recall Memory number 13 User Names can be programmed in to the memories using a keyboard See geNETics User guide section Giving product Memories names 17 MEM14 1 Recall Pressing this will recall Memory number 14 10 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 18 MEM15 1 Recall Pressing this will recall Memory number 15 19 BACK none Go To the Top Level Menus Menus 20 23 Memory 436 menus NEXT PREV to navigate Menu Num Heading Automation Function 20 MEM16 1 Recall Pressing this will recall Memory number 4 21 MEM17 1 Recall Pressing this will recall Memory number 5 22 MEM18 1 Recall Pressing this will recall Memory number 6 23 BACK none Go To the Top Level Menus Menus 24 27 Save memory 123 menus NEXT PREV to navigate Menu Num Heading Automation Functio