1. ja p Sp lt ep qp 3 OO 32 Feed Water Requirements Source Potable tap water pretreated by reverse osmosis ion exchange or distillation Feed water conductivity pS cm lt 5 TOC ppb max 50 Bacteria count CFU ml lt 100 Turbidity NTU lt 10 Temperature C 2 35 Pressure psi bar 1 4 87 0 1 6 Please see user manual for complete list of feed water requirements Product Specifications Operating pressure 7 Dimensions nma Electrical requirements Power consumption Feed water connector W x D x H in mm 29 87 psi 18 6 x 13 x 24 2 2 6 bar 472 x 330 x 615 Flow rate up to 2 L min 90 240V 50 60Hz 0 1kW 8 mm o d GenPure Pro su Pro nos Pro GenPure Pro GenPure Pro GenPure Pro UV UF UV TOC UV UF TOC GenPure Pro System At Systeme WnGlUGe a Wal brace Ulrapure eset DES 50131952 50131954 50131950 50131948 50131922 cartridge sterile 0 2 um filter pressure regulator and UV lamp and or ultrafilter where applicable Required Accessories Stainless steel DI cartridge DI 1500 APE aniy Waer ped Wathr 1S DISREAIER 02 1500 02 1500 02 1500 02 1500 02 1500 02 1500 using reverse osmosis to meet feed water requirements and prolong cartridge life Optional Accessories Printer Utilizes RS 232 interface for 110V AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1 safe documentationof all measured values and faults with date and time in compl
2. 7x26x7 in a p Harvey DI wee 1 2 NPTF 4 49 C 40 120 F 100 psig 4 L min T o ee 4 Ci 7 T gt fic com purewate r l PT 97 F a Thermo Scientific Barnstead B Pure continued Cartridges Size Dimensions Length x Diameter Full Size Cartridge 17 5 x 3 4 in Half Size Cartridge 10 95 x 3 4 in system Options Electrical Model number Single holder es nn D4511 Double holder with digital purity meter sti Double holder with Pura Lite indicator 50 k0 D4524 Double holder with Pura Lite indicator 200 k0 D5831 Double holder with Pura Lite indicator 1 MO D5833 Half size holder En D4505 Harvey DI AY1273X4 Ce 98 Required Accessories Choose the cartridge s according to your needs Anion removal Effective removal of weakly ionized impurities raises the pH of solutions recovers precious metal complex Cation removal Converts ionized salts to the acid form resulting in a product water that is low in pH ideal for precious metal or isotope recovery High capacity Removes ionized impurities produces a larger quantity of water than that of the Ultrapure D0809 however at a lower resistivity Pretreatment macropure Effectively removes colloids and bacteria increases filter life Organic removal Removes organics and chlorine Organic removal Removes organics and chlorine Ideal for pretreating water systems with high org
3. j i j pie A De n a A 6 5 SS Cleaning your purification system allows bacterial contaminants to be flushed away Changing the UV lamp protects the system against microorganisms and oxidizes organic compounds in the feed water allowing for TOC levels of less than 5ppb Thermo Scientific Barnstead Nanopure System Consumables Standard unit D11901 D11911 D11921 D11931 TOC moniter D11941 D11951 D11961 D11971 Replacement Consumables Diamond cartridge pack Deionized feed D50283 D50281 D50283 D50281 Choose the cartridge pack according to your feed water and system Ships with 0 2 um final filter 03750 D50280 Ultraviolet lamp system LMX13 Ultraviolet lamp TOC LMX26 104 Thermo Scientific Barnstead Easypure Il System Consumables D7381 Replacement Consumables Cartridge pack Deionized feed Choose the cartridge pack according to your feed water and system RO or distilled feed D502126 D502127 0 2 um final filter D3750 Ultraviolet lamp n a Ultrafilter n a Cleaning syringe CMX25 Thermo Scientific Barnstead Easypure RF System Consumables D7031 D7035 Replacement Consumables Cartridge pack Deionized feed D502126 D502124 Choose the cartridge pack according to your RO or feed water and system distilled feed D502127 D502125 0 2 um final filter D3750 D3750 Ultraviolet lamp n a LMX13 Ventgard reservoir cap CV703X4A CV703X4A Set of three empty cartridge
4. lt op iq ep Thermo Scientific Barnstead GenPure water purification system continued EE oe UV intensity monitoring provides superb reliability Easy cartridge replacement Feed Water Requirements Source Potable tap water pretreated by reverse osmosis ion exchange or distillation Feed water conductivity pS cm lt 2 TOC ppb max 50 Bacteria count CFU ml lt 100 Turbidity NTU lt 1 0 Temperature C 2 35 Pressure psi bar 1 4 87 0 1 6 Please see user manual for complete list of feed water requirements Product Specifications Operating pressure Electrical Power Feed water Dimensions min max requirements consumption connector W x D x H in mm 29 87 psi 14 6 x 13 x 24 2 2 6 bar 372 x 330 x 615 Flow rate up to 2 L min 90 240V 50 60Hz 0 1kW 34 hose connector GenPure GenPure GenPure GenPure GenPure GenPure UV UF UV TOC UV UF TOC UV UF GenPure system AN SYSTEME MOURE RWA Braco Ta een 50131211 20131243 50131235 50131217 50131229 50131256 cartridge sterile 0 2 um filter pressure regulator UV lamp and or ultrafilter where applicable Required Accessories Stainless steel DI cartridge DI 1500 peu ANY WAON IERAMEN 1S HIER 02 1500 02 1500 02 1500 02 1500 02 1500 02 1500 using reverse osmosis to meet feed water requirements and prolong cartridge life Optional Accessories Printer Utilizes RS 232 interface for safe
5. 30 Push button simplicity for easy dispensing GLP compliant documentation e Real time clock and code protected operating system prevents unauthorized changes to system settings e RS 232 interface with adjustable send interval for safe data transfer of all measured data faults date and time to a PC computer or log printer e Digital microprocessor contro automatically monitors and stores faults from the last four weeks e USP compliant conductivity measurement with temperature compensation can be switched on or off Tilting Control Panels for Easy Viewing e Ergonomically designed controller tilts for ease of use and better visibility e lluminated four line alpha numeric display Quick Look Comparison GenPure Pro GenPure Pro UV GenPure Pro UF GenPure Pro UV UF GenPure Pro GenPure Pro system system system system UV TOC UV UF TOC system system Biosciences cell and tissue culture HPLC ICP MS IC monoclonal antibodies HPLC IC ICP MS media PCR DNA TOC analysis cell culture media TOC measurements monoclonal antibodies ose s Chemical analysis trace analysis Molecular biology PCR DNA Inorganic and organic trace analysis Microbiology IVF monoclonal antibodies AA IC ICP Applications standard buffer flexible dispensing JC gt DU monitorinc www thermoscientific com purewater 31 m ja Le qp ja qp U
6. Storage reservoir e Supplying autoclaves and ultrapure water systems Optional Accessories e Preparing and diluting buffers reagents and media Bench stand Model 210 only A1066 Floor stand For Model 525 only M521 Lx W x D 36 x 18 8 x 35 in 93 x 48 x 89 cm Recirculation pump A1522 For Model 525 only Floor stand A1521 included Specifications and Ordering Information Product Specifications s Output Voltage 50 60 Hz n l ul gal hr Heating Amps Phase Wire ST CS Model number options L hr Controller re 2 7 6 24 x 41 x 15 25 in 60 x 103 x 39 cm A1065 B 210 still 2 7 6 24 x 41 x 15 25 in 60 x 103 x 39 cm A1065 D 5 19 36 5 x 48 x 18 75 in 91 x 122 x 48 cm A1085 B 525 still 19 36 5 x 48 x 18 75 in 91 x 122x 48 cm A1085 D O1 72 Distillation effectively removes most inorganic solids all organics with a boiling point greater than water 100 C all bacteria and pyrogens Gases and low molecular weight organics are not effectively removed by distillation Thermo Scientific Barnstead products Still components include a broad range of stills A still includes a boiling chamber boiler electric or steam immersion Our stills range in size from 1 4 to 38 L hr Select from stills heaters pyrogen reducing baffle condenser constant level device constructed of tin or glass Many models offer fully and low water cutoff Options include pretreatment solutions and fully automatic options or pre
7. TOC analysis Molecular biology microbiology PCR IVF monoclonal antibodies Molecular biology PCR DNA monoclonal antibodies cell culture media AA IC ICP Applications standard buffer Resistance at 25 C MQ cm TOC monitor n a n a standard standard 18 2 18 2 18 2 18 2 18 2 18 2 Visible ultrapure water quality Important measured values of conductivity resistivity Non Stop System 1 ppb TOC value of the and TOC are easy to see during dispensing ready for dispensing ultrapure water 18 2 MO cm e e _ 0 01 L Adjustable Resistivity of the volume to be ultrapure water dispensed 20 3 C Temperature UV TC UV lamp and measured for conductivity temperature compensation compensation switched on www thermoscientific com purewater 27 SWAISAS UONeINUN d 1878M ANdLNIN Thermo Scientific Barnstead GenPure xCAD water purification system continued 28 Our xCAD remote dispenser shown left The GenPure system is under the bench not pictured freeing up valuable bench space Thermo Scientific xCAD remote dispenser full system control in a compact design e xCAD is short for Extended Control and Dispenser The system provides more flexibility for ultrapure water dispensing with an action radius of 32 inches 80 cm e Ergonomic dispensing arm provides precise volume dosing at the press of a button e Turned height adjusted or extended towards your vessel y
8. required with purchase of softener 06 1000 06 1000 Alerts user when water is no longer softened North America Asia 50134335 50134335 Optional Accessories Sterile 0 2 um filter for reservoir outlet 06 5555 06 5555 Disinfection cartridge 09 2201 09 2201 Printer 110V AY1137X1 AY1137X1 Utilizes RS 232 interface for safe documentation of all measured values and faults with date and time in compliance with GLP Guidelines 230V 09 2207 09 2207 Qualification documents 1000 IOQDOCE50133916 IOQDOCE50133916 Replacement Consumables Ultrapure polisher cartridge 09 2005 09 2005 5 um filter and hardness stabilizer 06 5204 06 5204 Sterile 0 2 um filter for system 09 1003 09 1003 UV lamp for system 09 2002 09 2002 AO 09 2202 09 2202 Cleaning solution North America CMX25 CMX25 Reverse osmosis membrane 22 0046 requires 2 22 0087 requires 2 CE www thermoscientific com purewater 47 G 8 k AdAL ee je x CD Q CD R U C2 fab et Sp lt Sp qe 3 O Thermo Scientific Barnstead Smart2Pure water purification system All in one The Barnstead Smart2Pure system is a compact system which converts tap water to into both ASTM Type and Il water The Smart2Pure 3 and 6 feature a built in 6 L reservoir to store the Type 2 water The Smart2Pure 12 offers the choice of a 30 or 60 L reservoir for customizable storage capacity Powerful performance e Based on your requirements choose from capacit
9. No D8904 Full size oxygen removal Strong anion exchange wg No D8903 Full size pretreatment Mixed bed and strong cation 1250 grains Yes D8921 and scale eliminator exchange activated charcoal 1000 gal Full size ultrapure Ultrapure ion exchange 915 grains No D8911 l Ultrapure mixed bed ion l i Full size ultrapure 915 grains D8902 Full size ultrapure with Mixed bed ion exchange 730 grains Ves D8922 a organic removal with activated carbon 2000 gal 1 Alcohol containing samples can not be used in cartridges containing the color indicator Yes D8951 5 www thermoscientific com purewater 101 Thermo Scientific Barnstead 1 2 Size B Pure Filter Barnstead 1 2 Size B Pure Filters will meet all your prefiltration needs The filters can be used to pretreat feed water or act as a final filter to ensure consistently pure water Product features e Large surface area ensures long life e Flow rates of up to two L min Choose from two holder options 1 2 Size B Pure Filter Holder e Natural polypropylene material construction maintains purity e Filters are easily and quickly replaced with quarter turn quick release canisters e Accepts 10 inch 25 43 cm pre and post filters e Wall mounting bracket comes standard Economy Filter Holder e Accepts 10 inch 25 43 cm double open ended filters e Can be piped into any water line Optional accessory Pressure Gauge Kit e Attaches to any B Pure system e 0 to 160 psi p
10. e An additional measuring cell monitors feed water conductivity Any exceeding of the limiting value is immediately displayed to maximize cartridge life Online TOC measurement with UV intensity monitoring e Real time TOC monitoring for continual measurement of organic substances present in the water e Continuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity e Fault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements UV Photo oxidation 185 254 nm e High performance UV assembly reliably reduces the content of microorganisms and their metabolites Ready to use e Feed water pressure switch wall bracket UV lamp ultrapure cartridge sterile filter all included in one part number Measurement of conductivity resistivity e Conductivity cells are carefully calibrated prior to each measurement via built in reference resistance with cell constants at 0 01 cm e Temperature measurements are made by a platinum chip sensor with 0 1 C accuracy Quick connect cartridge replacement e Aquastop quick connect capability enables cartridge replacement within seconds even mid operation Exact dosing e High precision POM draw off valve for dispensing with sterile filter e Electronic dosing for fully automatic volume control of 0 01 65 0 L with lt 0 5 accuracy Product not available in all areas Speak to your representative about availability
11. e Capacities from 1 to 10 gal hr Low water cut off protects heating elements when water supply is interrupted Optional fully automatic controls allow for unattended operation Stops still when storage reservoir is full starts still when water level falls below preset level Drains still boiler at selected 2 4 8 16 hour intervals to reduce scale formation Steam Still e Utilize available in house steam as heat source e Optional automatic controls allow for unattended operation Stops still when storage reservoir is full starts still when water level falls below preset level Drains still boiler at selected 2 4 8 16 hour intervals to reduce scale formation e Rinsing lab glassware e Supplying autoclaves and ultrapure water systems e Preparing and diluting buffers reagents and media Quick Look Comparison Portable eee Steam Flectric Stills Floor Model Electric Stills Stills Mounting Specifications and Ordering Information Tin Coated Storage Reservoir Specifications Output Cooling OR Dimensions Model gal hr L hn en ER W x H x D in cm number SU9 JS S UONEINUNd 18 Nd 1 2 gal hr 0 5 1 9 21 52 19 49 10 26 A1007 22 56 66 168 10 25 A1011 A 1 gal hr 22 56 66 168 10 25 A1011 B 61 Electric stills Floor stand 23 58 68 173 11 28 A1013 B 61 included 2 gal hr except A1007 23 58 68 173 11 28 A1013 C 35 89 77 196 1
12. e Operating mode status such as production stand by disinfection e Reservoir volume in e Temperature in C with ultimate flexibility IV EC Quick Look Comparison Pacific TII Pacific TII Pacific TII Pacific TII Pacific TII 3 L hr system 7 L hr system 12 L hr system 20 L hr system 40 L hr system Pure water production at 15 C L hr 40 Removal bacteria and particles ee 99 SWA SAS UONEIINUNd 139 8M Bund Reverse osmosis membrane The high performance reverse osmosis membrane removes approximately 98 of inorganic ions and 99 of all dissolved organic substances as well as microorganisms and particles High purity water cartridge This cartridge further purifies the reverse osmosis permeate to produce high purity water as required by international standards ASTM Type Il CAP ISO 3696 BS 3997 and CLS UV lamp UV version only The 254 nm UV transmission ensures optimal UV irradiation Light of wavelength 254 nm acts as germicide Recirculation Recirculation of the water between the storage reservoir and Pacific TII is important for maintenance of the water quality Water from the reservoir is cycled through the high purity water cartridge and the UV chamber then back to the reservoir f thermoscientific com purewater 57 Thermo Scientific Barnstead Pacific TII water purification system continued The Barnstead Pacific TII system converts tap water to 15 10 MQ cm high purity wat
13. psi bar 1 4 87 2 6 Please see user manual for complete list of feed water requirements Product Specifications Operating pressure Flow rate Electrical requirements Power consumption Feed water connector min max W x D x H in mm 29 87 psi 17 7 x 22 8 x 59 1 up to 2 L min 2 6 bar 90 240V 50 60Hz 0 25 kW 450 x 580 x 1500 LabTower EDI 15 System Options LabTower EDI system All systems include an ultrapure polisher cartridge RO membrane RO pretreatment filters Dimensions LabTower EDI 30 5 um filter and hardness stabilizer EDI module UV lamp sterile 0 2 um filter SSIS SUES 10 inch 1 um filter reservoir outlet and pressure regulator Required Accessories Sterile overflow for reservoir Prevents the penetration of bacteria and other microorganisms a ai re CO absorber sterile filter 0 2 um Combination sterile filter with CO absorber will prevent CO from entering the tank saving cartridge life DEEE Yee Mix Multi Mini water softener 110V 50129892 50129892 Required if feed water silt density index SDI is greater than 3 Also required for purchase with a softener is the softener salt hardness detection kit and the 5 um filter with carbon 240V 06 1250 06 1250 For North America 50129893 50129893 Softener salt Required for use with the water softener For Europe 06 2000 06 2000 5 um filter with carbon cartridge Required when Mixed Multi is purchased SO eae oO Hardness detection kit
14. 0 1kW A hose connector 372 x 330 x 615 GenPure System with xCAD All systems include a wall bracket bench version oe ed oie eae aia es aon ultrapure polisher cartridge sterile 0 2 um filter pressure regulator UV with xCAD lamp and or ultrafilter where applicable 50131300 50131317 50131302 50131315 50131321 50131323 Required Accessories Stainless steel DI cartridge DI 1500 Required only when feed water Is pretreated using reverse 02 1500 02 1500 02 1500 02 1500 02 1500 02 1500 osmosis to meet feed water requirements and prolong cartridge life Optional Accessories Disinfection cartridge 09 2201 09 2201 09 2201 09 2201 09 2201 09 2201 Printer Utilizes RS 222 interface for safe 110V AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1 documentation of all measured values A ae ane ae 230V 09 2207 09 2207 09 2207 09 2207 09 2207 09 2207 compliance with GLP guidelines Qualification documentation 1000 10QDOCE5013318 10QD0CE5013318 10QDOCE5013318 100D0CE5013318 100D0CE5013318 I0QD0CE5013318 Storage reservoir 30 L to feed system Polyethylene tank opaque to light 23 5 x 14 9 in 598 x 380 mm H x W 06 5038 06 5038 06 5038 06 5038 06 5038 06 5038 Wall mount accessory is 06 5015 Storage reservoir 60 L to feed system Polyethylene tank opaque to light 35 9 x 14 9 in 912 x 380 mm H x W 06 5068 06 5068 06 5068 06 5068 06 5068 06 5068 Wall mount accessory is 06 5016 Replacement Consumables Ultrapure polisher
15. 33 4642 33 Required Accessories D5028 D5029 Tap feed D0835 Pretreatment 1 es a D5027 Ultrapure 2 D5027 Ultrapure 2 D5023 D5022 D0836 Macropure 1 Tap feed D0836 Macropure 1 D0803 High en 7 Organic free D5027 Ultrapure 1 D5027 Ultrapure 1 Cartridge kits D5021 Organic Free 1 j Choose the cartridge pack according to your DEAD Cele SE 0 feed water and need for organic free water el D0835 Pretreatment 1 D0809 Ultrapure 1 D5027 Ultrapure 2 Pretreated feed D50228 D0836 Macropure 1 D5027 Ultrapure 1 D0809 Ultrapure 1 D5021 Organic Free 1 Pretreated feed Organic free 1 1 Optional Accessories Remote dispenser Recirculates water through to tip of dispenser and includes a 0 2 um final filter D8952 D8952 Delivers water up to 8 ft 2 4 m from the system Ships with a mounting bracket Low pressure pump protector Alerts the E Pure of an inadequate feed water condition in a pressurized feed line Peas was Low water level pump protector REC D0603 D0603 Alerts the E Pure of an inadequate feed water condition when fed from a reservoir 2400 i D0606 D0606 Replacement Consumables 0 2 um final filter D3750 D3750 Cleaning cartridges Set of three D50223 D50223 CE www thermoscientific com purewater SWAISAS UOIEINUN 1378M sundesyy Thermo Scientific Barnstead LabTower EDI water purification system The Barnstead LabTower EDI is an integrated system co
16. 5452 Replacement UV lamp reservoir 230V only 09 5002 09 5002 63 www thermoscientific com purewater Thermo Scientific Barnstead Mega Pure Glass Stills Barnstead Mega Pure Glass Stills effectively remove inorganic solids organics with boiling points higher than water bacteria and pyrogens The stills are constructed of non leaching components to ensure high purity water Product Features e Contact with only glass quartz and Teflon components ensures ultimate purity and eliminates cross contamination Choice of five production capacities Units are easily wall or bench mounted Vertical condenser design provides maximum purity High temperature cut off shuts down the still if the temperature is too high preventing heating element burnout Quick release cover provides easy cleaning access Connection to Automatic Collection System ACS assures a 24 hour automatic system Includes feed water solenoid valve for automatic operation Produces water with a resistivity of 1 10 MQ cm depending on feed water purity MP 1 e Compact easy to use 1 L hr glass still available with or without a storage bottle MP 3A MP 6A and MP 11A e ideal for larger volume demands with storage and options e Rinsing lab glassware e Supplying autoclaves and ultrapure water systems MP 12A e Built in deionizer for pretreated feed to boiler Distillate cooler allows product water to be used as it is produced cooling it from 85 55
17. 9 in 912 x 380 mm opague to light 100 L 49 2 x 14 9 in 1249 x 380 mm 58 System Options UV option Pacific TII 3 Pacific TII 7 Pacific TII 12 Pacific TII 20 50131982 Pacific TII Systems All systems have a built in wall bracket and 90132129 90132131 90132132 include an RO membrane a high purity water cartridge pressure regulator and UV lamp where applicable Required Accessories Pacific TII Reservoir Choose a reservoir that fits your needs ER SE ERE RES OIE BUEN Mes Double cartridge pretreatment system A 5 um filter with activated carbon cartridge and a hardness stabilizer cartridge ship complete with two 10 inch filter housings to control chlorine organic impurities and control hardness lt 250ppm TIS For full pretreatment options see p 86 09 4000 Optional Accessories Qualification documents 1000 Water watcher Alerts the user to leaks available as 230V only 16 0129 16 0129 Printer Utilizes RS 232 interface for safe documentation of all measured values and faults with date and time in compliance with GLP Guidelines 110V AY1137X1 AY1137X1 AY1137X1 AY11 paren 230V 09 2207 09 2207 09 2207 09 2207 09 4011 09 4011 09 4011 09 4011 22 0046 22 0046 22 0046 22 0046 094002 4002 094002 4002 09 4002 09 4002 Europe Asia Pacific a a 09 2202 09 2202 North America CMX25 CMX25 CMX25 CMX25 Activated carbon cartridge with 5 um prefilter 06 5201 06 5201 06 5201 06 5201
18. All GenPure systems exceed international standard ASTM Type I ISO 3696 Grade 1 ASTM D1193 and CLSI CLRW Integrated feed water monitoring e An additional measuring cell monitors feed water conductivity Any exceeding of the limiting value is immediately displayed maximizing cartridge life Online TOC measurement with UV intensity monitoring e Real time TOC monitoring for continual measurement of organic substances present in the water e Continuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity e Fault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements UV Photo oxidation 185 254 nm e High performance UV assembly reliably reduces the content of microorganisms and their metabolites Ready to use e Feed water pressure switch wall bracket UV lamp ultrapure cartridge sterile filter all included with one part number Measurement of conductivity resistivity e Conductivity cells are carefully calibrated prior to each measurement via built in reference resistance with cell constants at 0 01 cm e Temperature measurements are made by a platinum chip sensor with 0 1 C accuracy Molecular Biology and Microbiology e Cell and tissue culture e PCR DNA sequencing e Electrophoresis Quick connect cartridge replacement e Aquastop quick connect capability enables cartridge replacement within Analytical Chemistry seconds even mid op
19. cartridge 09 2005 09 2005 09 2005 09 2005 09 2005 09 2005 Sterile filter 0 2 um 09 1003 09 1003 09 1003 09 1003 09 1003 09 1003 UV lamp 09 2002 09 2002 09 2002 09 2002 Europe 09 2202 09 2202 09 2202 09 2202 09 2202 09 2202 Cleaning solution North America CMX25 CMX25 CMX25 CMX25 CMX25 CMX25 29 www thermoscientific com purewater Q O cD pare qe U C2 Fab WM lt oe qe op Thermo Scientific Barnstead GenPure Pro water purification system The Barnstead GenPure Pro system delivers ultrapure 18 2 MQ cm water with consistent quality Suitable for the most demanding laboratory applications this ultrapure water system will deliver water from a small footprint The GenPure Pro system can be used on a laboratory bench or on a wall The new flexible dispenser offers maximum freedom while dispensing ultrapure water up to 24 inches 60 cm away from the unit Molecular Biology and Microbiology e Cell and tissue culture e PCR DNA sequencing e Electrophoresis Analytical Chemistry e HPLC e GC GC MS ICP MS AA e TOC Measurements IC All GenPure systems exceed international standards ASTM Type ISO 3696 Grade 1 ASTM D 1193 and CLSI Dispensing for a variety of tasks e New flexible dispenser offers a radius of 24 inches 60 cm from the system for filling larger vessels or glassware washing Integrated feed water monitoring
20. feed water quality doesn t match the requirements for your system DI 1500 cartridge RO water quality can vary so it is recommended that systems fed with RO water have additional ion removal Deionized and distilled water will meet the feed water requirements for the Thermo Scientific GenPure and Micropure families No pretreatment is typcially required Pacific TII and reservior or LabTower TII Utilize a Type 2 system to pretreat the Genpure and Micropure families Pretreatment Filter 1 um filter Mix Multi Mini Water softener The softener is required for most customers who have unsoftened 110V tap water or a TIS of more than 10ppm Additionally you will need to replace the hardness stabilizer cartridge that ships with the unit with a 230V 5 um filter with activated carbon Pretreatment Filter 1 um filter Ships with two 10 inch filter housings It is ideal to place largest pore filter before smaller so put the 5 um filter with hardness stabilizer Ships with the unit before the 1um filter for optimal performance Designed for customers without chlorine in their tap water typically Europe and Asia Pretreatment Filter with carbon 5 um filter with activated carbon 1 um filter Ships with two 10 inch filter housings Designed for customers with chlorine in their tap water typically North America and UK Single Pretreatment System 5 um filter with hardness stabilizer cartridge Ships with two 10 inch filter housing
21. of the Ventgard filter assembly www thermoscientific com purewater 71 Thermo Scientific Barnstead Cabinetized Stills Our Barnstead Cabinetized Stills include a still and an appropriately matched tin coated storage reservoir in a compact storage cabinet This space saving design uses less space than conventional units and allows for faster installation all in one tin lined still and reservoir Product Features e Choice of two sizes 2 or 5 gal hr e Q Baffle ensures high quality pyrogen free product water e Fully automatic operation allows for unattended operation Still turns off when the reservoir is full and restarts when reservoir empties Automatically drains the boiling chamber every time the unit is off and every 4 hours of operation helping to keep your still clean Model 210 Still 2 gal hr with 10 gallon reservoir e Purity meter alerts user of distilled water purity in storage reservoir e Includes low water cut off for safety protection Model 525 Still 5 gal hr with 25 gallon reservoir The inside of e Purity meter alerts user of distilled water purity in storage reservoir a Barnstead e Optional recirculation pump and base mounting stand available Cabinetized Still e Storage tank equipped with a UV lamp for improved bacterial control Quick Look Comparison ROUTINE LABORATORY WORK Model 210 Model 525 2 gal hr 10 gal 5 gal hr 25 gal oer Flow rate e Rinsing lab glassware
22. or concern contact our PURE Water Experts Technical Questions Our technical service team is ready to answer any of your questions on your existing Systems 106 Customer Service Let our professional and experienced customer service representatives guide you when choosing your water system They will evaluate your needs develop a System recommendation and coordinate the installation of your water system New Lab Construction We offer the most comprehensive line of water purification systems in the world We can design a water system to meet your new lab s needs Services Maintaining your water purification system is crucial to the overall productivity of your laboratory the long term performance of the system and the total cost of ownership We offer a variety of services to suit your individual needs Professional service delivers improved productivity convenience peace of mind and budget control Preventative maintenance Installation To ensure your system is working Our factory trained technicians can within specifications regular install your system to ensure it operates maintenance is essential We offer with precision With our services you various service options and preventative will receive maintenance which will extend the working life protect your system and e Installation scheduled at your prevent costly breakdown convenience e Assurance that all technical specifications are met e Prac
23. ppb 1 000 000 Parts Per Trillion ppt 1 ppb 1 Microgram Per Liter ug L 1 ppm 1 5 uS cm Resistivity Conductivity 1 megohm cm 1 uS cm 1 umho cm Calculating lon Exchange Capacity Cartridge Grain Capacity Total Dissolved Solids Grains Gal Gallons Processed Cartridge Grain Capacity x 17 1 Total Dissolved Solids ppm Gallons Processed Cartridge Grain Capacity x 64 7 Total Dissolved Solids ppm Liters Processed www thermoscientific com purewater 109 _ glossary 110 Absorption Process by which one substance is taken up by another either chemically or physically as when a sponge soaks up a liquid Activated Carbon Material used to adsorb organic impurities from water Anion Exchange Resin An ion exchange material that removes anions from solution by exchanging them with hydroxyl ions Bed Column of carbon sand or ion exchange resins through which the water passes during treatment Cation Exchange Resin lon exchange resins capable of removing cations by exchanging them for hydrogen ions Conductivity The reciprocal of resistivity it is a measure of the ability to conduct an electric current Since ionized impurities increase the conductivity of water it is also an accurate measure of ionic purity To measure it current is passed between two electrodes a fixed distance apart Conductivity is normally expressed as microsiemens cm identical to microm
24. q High performance liquid chromatography HPLC e o Gas chromatography GC gt D lon chromatography IC ooo D Inductively coupled plasma spectroscopy ICP ooo D Mass spectroscopy MS ooo D me boron AA O D Total organic carbon TOC ooo LUO Life Sciences 4 Genomics ex PCR mutagenesis ES A Proteomics ex crystallography electrophoresis C O OO Immunology ex monoclonal antibody production blots ooo D Cell and tissue culture Drug discovery www thermoscientific com purewater 17 Barnstead GenPure water purification system What Thermo Scientific Barnstead water systems provide Our water systems are engineered to be used independently or in conjunction with our other water systems for more flexibility Below is a summary of our product lines for each water type Ultrapure Type 1 Water This grade of water is required for your most sensitive and critical laboratory applications Type 1 water can be made pyrogen nuclease bacteria and particulate free It has the highest purity but is also the most expensive to generate If your applications require different types of water let our experts assist with designing a water purification system specific to your needs The below systems provide you with the Type 1 water you need for your applications e Thermo Scientific Barnstead LabTower EDI water purification system e Thermo Scientific Barnstead Smart2Pure water purific
25. reverse osmosis purification system selector guide Technology Feature amp Optimal amount of water to use daily to sustain reasonable cartridge life Upgradable Feed water monitoring Integrated 100 L Reservoir Pretreatment integrated into system Benefits gt Choosing the right system will give you the most value Take into account any new applications you will introduce in the coming years or new volume demands you may have If capacity needs increase the system can be upgraded Alerts you to fluxuations in feed water quality Offers a stand alone configuration for labs with little bench space Pretreatment integrated into system Flexible mounting options 3 7 12 20 40 L hr Standard Standard Integrated 100 L Reservoir 20 40 L hr Standard Standard Standard Standard PA dd WWW Thermo Scientific Barnstead LabTower RO water purification system The Barnstead LabTower RO Converts Tap Water into RO Water and stores it in an integrated 100 L reservoir Advanced technology in a mobile design e An ultra modern controller provides easy to read system parameters e Completely drainable integrated 100 L high purity water reservoir has a low noise pressure booster as a standard component e Mounted on casters the compact LabTower RO system is an ideal pure water supply for any laboratory Ideally suited as a feed water source for dishwashers autoclave
26. that is capable of producing Type 1 water free of nucleases pyrogens and bacteria Our Barnstead GenPure xCAD UV UF system is perfect for their ultrapure water needs Our Barnstead Pacific TII which will produce water for the general lab uses will also serve as feed water for the GenPure xCAD UV UF Pretreatment Barnstead LabTower TII Barnstead GenPure Pro UV water purification system water purification system Tap water LabTower TII reservoir water feeds the GenPure Pro ICP MS GC MS HPLC Chemical and Buffer Prep Water Type s Needed Type 1 with low organics and Type 2 water Applications in the Lab Solution Barnstead LabTower TII and the Barnstead GenPure Pro UV The Le Lab performs analytical experiments on a daily basis They would like to make their own buffers and reagents so we suggested a configuration that would give the lab both Type 1 and Type 2 water Our Barnstead LabTower TII converts tap water into Type 2 water which is stored in the 100 L integrated reservoir Water can be drawn from the reservoir or from our Barnstead GenPure Pro UV which has a 0 2 um on it to ensure bacteria free water The reservoir feeds our Barnstead GenPure Pro system which will deliver ultrapure Type 1 water Speaking the Language of Pure Water Mix and Match for Greater Flexibility Dual Cartridge Deionizer Barnstead Mega Pure Still with Barnstead MicroPure UV Automatic Collectio
27. water H30 Deionization is the only technology which produces the resistivity requirement for Type 1 reagent grade water In laboratory water systems cation and anion resins are most often mixed together allowing them to achieve maximum ionic purity Two bed deionization The cation and anion resin are in separate halves of a cartridge In general this method is less effective deionizing water as compared to the mixed bed deionization however it is more tolerant of other types of impurities Mixed bed deionization We use semi conductor grade mixed bed deionization resin to achieve maximum resistivity and low TOC Mixing the cation and anion resin drives the deionization to completion making it more efficient and more effective at the removal of ions Benefits e Removes dissolved inorganics ions very effectively e Produces product water with a resistivity above 18 MQ cm Limitations e Finite capacity once all ion binding sites are occupied ions are no longer retained and the cartridge must be replaced e Does not remove organics particles pyrogens or bacteria Systems that utilize this technology e Thermo Scientific Barnstead GenPure MicroPure E Pure LabTower EDI Smart2Pure Pacific TII LabTower TII and the Bantam water purification systems Hose Nipple and B Pure cartridges Cation Resin Diagram showing how cations and anions are exchanged on the resin 50 000 to 300 000 Q_cm 1 18 MQ_cm W
28. 06 5452 06 5452 06 5452 06 5452 30 L 60 L with level display 06 5033 06 5063 with level display and recirculation pump 06 5032 06 5062 06 5001 06 5001 Sterile filter 0 2 um 06 5003 06 5003 Sterile filter 0 2 um CO absorber 06 5002 06 5002 06 5006 06 5006 06 5015 06 5016 09 5002 09 5002 Replacement Consumables High purity water cartridge Reverse Osmosis membrane Pacific TII 3 7 12 only require a single RO membrane Pacific TII 20 and 40 require two membranes as indicated order 2 System UV lamp Cleaning solution Hardness stabilizing cartridge Storage Reservoir Options for Pacific TII Reservoir Choose a tank to meet your capacity and pump Required Accessories Sterile overflow for reservoir Vent filter Choose the vent filter for your application needs Optional Accessories UV lamp assembly for reservoir with lamp 230V Wall mounting bracket Replacement Consumables Replacement UV lamp Reservoir www thermoscientific com purewater 90132133 ETS 90132121 90132123 90132124 90132125 ER IDQDOCE50133915 I0QDOCE50133915 I0OQDOCE50133915 I0QDOCE50133915 I0QDOCE50133915 16 0129 16 0129 16 0129 AY1137X1 Pacific TII 40 SWA SAS UOICOLN 1972M Bnd 09 2207 09 4011 22 0087 order 2 09 4002 09 2202 CMX25 06 5201 06 5452 100 L 06 5083 06 5082 06 5001 06 5003 06 5002 06 5006 na 09 5002 59 Thermo Scientific Barnste
29. 100 L day 200 L day 1560 L day www thermoscientific com purewater 25 Thermo Scientific Barnstead GenPure xCAD water purification system The Barnstead GenPure xCAD system delivers ultrapure 18 2 MQ cm water with consistent quality for the most demanding and sensitive applications The xCAD remote dispenser provides flexibility and control Molecular Biology and Microbiology e Cell and tissue culture e PCR DNA sequencing e Electrophoresis Analytical Chemistry e HPLC e GC GC MS ICP MS AA e TOC Measurements IC 26 All GenPure systems exceed international standards ASTM Type ISO 3696 Grade 1 ASTM D1193 and CLSI CLRW Integrated feed water monitoring e Additional measuring cell monitors feed water conductivity If the quality of the feed water drops below the set value a fault message will immediately be displayed Online TOC measurement with UV intensity monitoring e Real time TOC monitoring for continual measurement of organic substances present in the water e Continuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity e Fault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements UV Photo oxidation 185 254 nm e High performance UV assembly reliably reduces the content of microorganisms and their metabolites Ready to use e Feed water pressure switch wall bracket UV lamp ultrapure cartridge sterile filte
30. 110V AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1 AY1137X1 documentation of all measured values and faults with date and time in 230V 09 2207 09 2207 09 2207 09 2207 09 2207 09 2207 compliance with GLP guidelines Qualification documentation 1000 I0QDOCE50133917 10QDOCE501 33917 OQDOCE50133917 I0QDOCE501 33917 IOQDOCE50133917 I0QDOCE50133917 Disinfection cartridge 09 2201 09 2201 09 2201 09 2201 09 2201 09 2201 Storage reservoir 30 L to feed system Polyethylene tank opaque to light 23 5 x 14 9 in 598 x 380 mm H x W 06 5038 06 5038 06 5038 06 5038 06 5038 06 5038 Wall mount accessory is 06 5015 Storage reservoir 60 L to feed system Polyethylene tank opaque to light 35 9 x 14 9 in 912 x 380 mm Hx W 06 5068 06 5068 06 5068 06 5068 06 5068 06 5068 Wall mount accessory is 06 5016 Replacement Consumables Ultrapure polisher cartridge 09 2005 09 2005 09 2005 Sterile filter 0 2 um 09 1003 09 1003 09 1003 Ultrafilter n a n a 50133980 UV lamp n a 09 2002 09 2002 Europe 09 2202 09 2202 09 2202 09 2202 09 2202 09 2202 Asia Pacific CMX25 CMX25 CMX25 CMX25 CMX25 CMX25 CE System Options eb Le x cD o qe es U CD o O WM lt op qe O Cleaning solution North America www thermoscientific com purewater 37 Thermo Scientific Barnstead MicroPure water purification system The Barnstead MicroPure system was designed for labora
31. 12 Thermo Fisher Scientific Inc All rights reserved CLSI CLRW is a registered trademark of the Clinical and Laboratory Standards Institute Teflon is a registered trademark of E I du Pont de Nemours and Company All other trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries Specifications terms and pricing are subject to change Not all products are available in all countries Please consult your local sales representative for details Australia 61 39757 4300 India toll free 1800 22 8374 Russia 7 812 703 42 15 Austria 43 1 801 40 0 India 91 22 6716 2200 Spain Portugal 34 93 223 09 18 Belgium 32 53 73 42 41 Italy 39 02 95 05 92 54 Switzerland 41 44 454 12 22 China 86 21 6865 4588 or Japan 81 45 453 9220 UK Ireland 44 870 609 9203 86 10 8419 3588 Netherlands 31 76 579 55 55 France 33 2 2803 2180 New Zealand 64 9 980 6700 Other Asian countries 852 2885 4613 Germany national toll free 08001 536 376 Nordic Baltic CIS countries Countries not listed 49 6184 90 6900 Germany international 49 6184 90 6000 358 9 329 10200 BRWPBOOK 0412 Thermo SCIENTIFIC Part of Thermo Fisher Scientific
32. 3 x 96 5 x 41 3 cm ACS wall mounting bracket Adapter for ACS washer hook up for glassware washers Model Number 413964 410535 413934 410164 B440704 440138 400634 440241 Thermo Scientific Barnstead Classic Stills Barnstead Classic Stills effectively remove inorganic solids organics bacteria and pyrogens The stills are constructed of copper and bronze with a coating of pure tin The inert nature of tin prevents any leaching of contaminants into the water Product Features e Double walled boiler and preheating of feed water conserves electricity e Vented condenser allows for stripping of gaseous impurities e Unique de concentrator removes scale forming impurities from the boiler e Unique Thermo Scientific Q Baffle ensures high quality pyrogen free water by stripping contaminant laden water droplets from steam e Space saving horizontal condenser e Metal construction withstands years of use e Units are easily floor and bench mountable depending on model e Inert pure tin pathways assure product water quality e Controller unit can be wall mounted Portable Stills e Requires no permanent plumbing or electrical connections allowing quick set up e Includes low water cut off for safety protection e Bench mounted Floor Model Electric Stills e Come standard with floor mounting stand e New over temperature protection system improves safety e New plug and play hardware allows for easier installation
33. 4 36 A1015 B 61 5 gal hr 5 19 40 151 08 36 3 10 gal hr 10 38 80 303 2 20 6 3 37 94 89 226 14 36 A1016 D Output Cooling gal hr water gal hr L hr L hr 10 gal hr 10 38 38 144 35 50 90 41 90 229 150 330 19 48 A1213 Model Number Steam pressure Boiler Steam lb hr Dimensions Model Steam stills PSI horsepower kg hr W x H x D in cm Number Required Accessories Steam still floor stand For 10 gal hr steam stills only G1000 Choose a storage reservoir that best fits your needs go to Thermo Scientific Barnstead Classic Still Storage Reservoirs and Accessories on pages 70 71 Storage reservoir Optional Accessories i For use with 1 and 2 gal hr electric stills G2100 Fully automatic controls 120V 50 60Hz includes feedwater For use with 5 gal hr electric stills G2110 and drain solenoid valves manual For use with 10 gal hr electric still G2125 Nemes PIPINO ANC eve MONO For use with 10 gal hr steam still G2020 ICO IC pure water www thermoscientific com purewater 69 an m 3 e a at Thermo Scientific Barnstead Classic Still Storage Reservoirs and Accessories Select a Barnstead Classic Still Storage Reservoir and mounting option that will best fit your needs The Ventgard Air Filter Water Seal and UV Light Assembly are required accessories that will protect your pure water during storage 70 Storage Rese
34. C for ease of handling No need to wait for cooling e Preparing and diluting buffers reagents and media Quick Look Comparison MP 1 MP 3A MP 6A MP 11A MP 12A Deionizer System features Compact Stills for larger volume demands and distillate easy to use cooler Cooling water capacity L hr 11 3 130 130 Resistivity at 25 C MO cm 1 10 1 10 110 1 10 1 10 64 Product Accessories All glass system designed to collect water from the Mega Pure Glass Stills and control their operation Generous 45 L capacity Easy wall or bench mount Preset to shut off the power to the heaters and the water supply to the still after the bottle has collected approximately 45 L The system will automatically restart the still and refill the collection system when the purified water supply has been depleted to approximately 38 L Allows for pretreating feed water to Mega Pure Glass Stills Mega Pure single or dual cartridge deionizer reduces scale build up and increases distillate purity Greater flexibility in meeting varying feed water qualities Temperature compensated purity meter measures water quality and indicates when cartridges are exhausted Built in drain valve for simple cartridge changes Large cartridge capacity for extended cartridge use Unit can be wall or bench mounted biological applications 4 A Plastic Bottle 413964 Glass Bottle 410535 Automatic Collection System Mega Pure De
35. Developed to fulfill GLP requirements e Recorded and traceable data can be obtained by print out via the RS 232 interface and accessory printer e Highly qualified and precise measurement of the conductivity is ensured by the cell constant of 0 16 cm Quick Look Comparison LabTower RO 20 LabTower RO 40 Pure water production at 15 C L hr 40 Withdrawal performance from reservoir at 1 5 bar L hr 180 Retention quota for inorganics gt 98 Bacteria content gt 99 Retention quota for particles gt 99 a A Source Potable tap water that has been softened or hardness stabilized lt 5 With higher values a pretreatment Sle density index ou model no 09 4000 must be installed upstream of the system Conductivity uS cm lt 1500 Free chlorine mg L lt 0 1 pH Range 4 11 Temperature C 2 35 complete list of feed water specifications can be found in the operational manual LabTower RO Product Specifications Operating pressure Electrical requirements Power consumption Feed water connector 29 87 psi 2 6 bar system Options LabTower RO Systems All systems include an RO membranes 10 inch Sum filter with hardness stabilizer cartridge integrated 100 L reservoir and pressure regulator Required Accessories 90 2404 5 60 025K Dimensions WxDxH 17 7 x 22 8 x 59 in 450 x 580 x 1500 mm LabTower RO 20 90132390 Sum filter with activated carbon 50134022 Pretreatment cartri
36. Double Pretreament System 09 4000 10 in 25 4 cm Hardness stabilizing cartridge 06 5452 10 in 25 4 cm 5 um filter with activated carbon cartridge 06 5201 Triple Pretreatment System es 10 in 25 4 cm Hardness stabilizing cartridge 06 5452 10 in 25 4 cm 1 um filter 06 5101 Mix Mut Mini 2300 6 125 0 100 Mix Muti mini 100 50120802 50134335 Mix Multi Mini 230V Max flow rate L h 500 Filter volume L 5 Capacity m at 10 dH 2 Salt storage kg 20 Operating pressure psi bar 20 87 1 4 6 Water temperature max C 40 Controller time controlled Dimensions W x D x H in mm 9 x 17 7 x 22 230 x 450 x 560 Model number 06 1250 What is SDI e SDI is a measure of the fouling capacity of water in RO systems SDI stands for silt e The test measures the rate at which a 0 45 um filter is plugged density index SDI when subjected to a constant water pressure of 30 psi When the SDI of feed water is gt 3 it can quickly e SDI gives the percent drop per minute in the flow rate of the ruin your RO membrane water through the filter averaged over a period of time such as 15 minutes www thermoscientific com purewater 91 92 cartridges and filter systems We offer a complete line of cartridge and filter systems for all your single step purification and pretreatment needs Use the Thermo Scientific Bantam Deionizer Hose Nipple Cartridges or B Pure cartridges for simple single step purifications CET inno
37. Hose Nipple Cartridges Barnstead B Pure 1 2 Size Filters Legacy Water System Consumables Type 1 systems Type 2 3 systems Support and Maintenance Contact the Pure Water Experts Services Go Green Common Conversions Glossary www thermoscientific com purewater 22 26 30 34 38 40 44 48 52 56 60 64 68 70 72 73 74 80 82 86 92 96 100 101 102 104 104 105 106 106 107 108 109 water experts Our complete line of water purification technologies includes solutions for your most critical and everyday application needs from electrodeionization to reverse osmosis and distillation pure Thermo Scientific Barnstead pure water systems deliver innovation Our water purification portfolio features advanced ergonomics and technology including remote dispensing and UV intensity monitoring that offer users full control with confidence flexibility Laboratory environments often have limited bench space Our portfolio offers numerous mounting options small footprints and flexible dispensing options to provide you the luxury of designing a configuration that best suits your lab Many water systems can be easily upgraded to allow for additional capacity convenience Our Thermo Scientific H20 Select Kit Analysis program and complete all in one box ordering gives you the confidence to select the right solution Receive a complete water system using one part number and have the co
38. RS 232 data printing at pre programmed intervals Optimal amount of water to use daily to sustain reasonable cartridge life Benefits gt UV oxidation is necessary for the removal of organics in the feed water reduces organic levels to gt 5 ppb and protects against microorganisms Ultrafiltration removes pyrogens from the feed water UV UF is the most common combination of technologies used to reduce organics and remove pyrogens and nucleases Photosensor continually checks the intensity of the UV lamp A decrease could result in an incorrect TOC measurement result Feed water monitoring alerts you to fluctuations in feed water quality Real time monitor of the amount of organic materials in the product water shown on the display Dispense at the push of a button Control from 0 01 65 liters with an accurancy of lt 0 5 Allows for full control of the system at the GenPure xCAD remote dispenser Ideal when bench space is tight System sits under the bench and out of sight Satisfies GLP guidelines data available inprint Expands with your laboratory and application needs Full control at the GenPure Flexible Economical Smaller capacity Simple design Produces Compact unit Type 1 and 2 with producing EDI technology Type 1 and 2 XCAD remote dispensing Type 1 water for optimal value great value dispenser J ES SA SN pnp bs bos ES S J J J S J J 200 L day 200 L day 200 L day 15 L day
39. TM Standards for Reagent Water Measurement unit OO A C Heterotrophic bacteria count CFU ml 10 1000 10 100 1000 10 Endotoxin units per ml 0 25 n a Here are some additional definitions of the parameters they use to indicate the water s purity Resistivity the tendency of water without ions to resist conducting electricity The unit of measure is megohm centimeter MQ cm often shortened to MQ or meg It is generally used for high purity water The theoretical maximum is 18 2 MQ cm at 25 C The higher the ionic content the lower the resistivity and the lower the ionic content the higher the resistivity high resistivity is good In ultrapure water systems this value is determined using an in line meter Conductivity and resistivity measurements are inversely related to each other Conductivity the tendency of water that contains ions to conduct electricity The unit of measure is microsiemens centimeter uS cm or microhm cm The measurement is used to measure feed water or lower quality treated water The more ions present in the water the higher the conductivity This is measured by a conductivity meter Total Organic Carbon TOC a measure of the organic contaminants found in water The unit of measure is parts per million ppm or parts per billion ppb Feed water can be in the 2 5 ppm range and the best high purity water should be in the 1 5 ppb range Measurement o
40. Thermo Scientific Waterbook Pure Water 101 I r For more than 130 years Thermo Scientific pure water systems have been a trusted resource for science and industry Introduction Thermo Scientific Barnstead Water Purification Technologies Distillation Filtration and Ultrafiltration Reverse Osmosis Deionization Electrodeionization Adsorption Ultraviolet Oxidatation International Water Standards Advanced Technologies Used to Monitor Purity Conductivity and Resistivity Build Your Own Water System What Type of Water Do You Need Ultrapure Type 1 Water Pure Type 2 Water Reverse Osmosis RO Water Cartridge and Filter Systems Lab Case Studies 14 15 16 Thermo Scientific Water Purification Products KT S 5 ee E Type 1 Ultrapure Water Purification Systems Barnstead GenPure Pro xCAD Barnstead GenPure Pro Barnstead GenPure Barnstead MicroPure Barnstead E Pure Barnstead LabTower EDI Barnstead Smart2Pure Type 2 Pure Water Purification Systems Barnstead Pacific TII Barnstead LabTower TII Barnstead Mega Pure Glass Stills Barnstead Classic Stills Barnstead Classic Still Storage Reservoirs and Accessories Barnstead Cabinetized Stills Barnstead Distillation 101 Reverse Osmosis Water Purification Systems Barnstead LabTower RO Barnstead Pacific RO Pretreatment Cartridge and Filter Systems Barnstead B Pure Barnstead Bantam Deionizer Barnstead
41. ad LabTower TII water purification system The Barnstead LabTower TII converts tap water into high purity water and provides water storage for a complete Type 2 water solution e Rinsing lab glassware e Supplying autoclaves and ultrapure water systems e Preparing and diluting buffers reagents and media 60 Consistent water quality e Type 2 laboratory water meets ASTM Type Il CSLS CLRW and ISO 3696 international standards e Designed to continuously recirculate purified reservoir water to preserve water quality even during periods of inactivity Compact mobile design e Two system options with permeate flows of 20 or 40 L hr e Stand alone design with integrated 100 L reservoir takes up zero bench space e Castors allow easy re location e Systems can be upgraded later to accommodate growing water demands Two ways to dispense water e Dispense directly from the system via the dispensing valve for calibration solutions reagent preparation filling of containers general rinsing purposes etc e Dispense from the reservoir to supply autoclaves dishwashers ultrapure water systems etc Integrated 100 L reservoir e Up to 100 L of high purity water ready for dispensing when needed e High purity polypropylene reservoir is opaque to light e Conical bottom allows complete emptying for efficient cleaning and disinfection e Adjustable setting for reservoir volume can be programmed for times when demand is low allo
42. and disinfection e PCR DNA sequencing e Electrophoresis Analytical Chemistry e HPLC e GC GC MS ICP MS AA e TOC Measurements IC Routine Laboratory Work e Preparing and diluting buffers and reagents e Rinsing lab glassware e Supplying autoclaves and other small lab equipment LT compact dual quality system 48 lt U m h Qo NO Quick Look Comparison Type 1 Water Inorganic and organic trace eee Molecular biology PCR analysis HPLC ICP MS e ee ae DNA monoclonal antibodies IC TOC analysis cell culture media AA IC ICP Applications standard buffer Resistivity at 25 C MQ cm 18 2 Conductivity pS cm 0 055 TOC value ppb 1 5 Bacterial content CFU mL lt 1 SW JS S UONCDIUN 1878M 91nde4 N Particles um mL lt 1 Endotoxines EU mL lt 0 001 Flow rate L min 1 Type 2 Water Pure water production at 15 C L h 3 6 or 12 Resistivity at 25 C MO cm 1510 15 10 15 10 15 10 Conductivity 1S cm 0 067 0 1 0 067 0 1 0 067 0 1 0 067 0 1 Feed Water Requirements Source Potable water acc to DIN 2000 pH range 4 11 Temperature C 2 35 Pressure psi bar 1 4 87 1 6 Please see user manual for complete list of feed water requirements Space Saving Design Simply stand the Smart2Pure system on the benchtop or mount it directly to the wall as shown by the Thermo Scientific MicroPure for more bench space www thermoscientific com purewater Ther
43. anic levels in the feed water Oxygen removal Maintains low oxygen content to prevent corrosion in cooling water loops etc The feed water should contain less than 10 ppm of ionized solids Oxygen and demineralization Ultrapure Removes ionized impurities to produce high resistivity water with a neutral pH Ultrapure and organic removal Commonly used as still pretreatment Removes ionized impurities and has a layer of activated carbon to remove chlorine and organics Ultrapure and oxygen removal Ultrapure oxygen and organic removal Optional Accessories Digital Purity Monitor Resistivity range of 0 1 18 2 MQ cm Indicator light at 50 000 Q cm Pura Lite Indicator light at 200 000 Q cm Indicator light at 1 000 000 Q cm 1 to 75 L hr using 1 8 inch NPT inlet Flow meters 0 to 190 L hr using 1 8 inch NPT inlet 0 2 um final filter For use on Double Holder units D S ESA off Resin type s Strong anion exchange Strong cation exchange Two bed ion exchange Macroreticular activated carbon Activated carbon Extruded carbon Porous strong anion exchange Cartridge size Full Full Full Full Half Half Oxygen removal mixed bed Mixed bed Mixed bed activated carbon Ultrapure oxygen removal Ultrapure oxygen and organic removal www thermoscientific com purewater Half Full Half Full Full SE L1eIt Lavo Capac
44. ater Inlet Two Bed Mixed bed Water Inlet Two bed resin is shown on the left and mixed bed resin in on the right Speaking the Language of Pure Water Purified water lt 0 1p5 cm Cathode Feedwater Anion permeable Permeate from RO system d 30 pS cm membrane Process of electrodeionization Electrodeionization EDI In contrast to conventional ion exchange in which resins are exhausted and must either be thrown away or chemically regenerated EDI utilizes an electric current for continual resin regeneration How EDI works Benefits e Effectively removes ions Several layers of ion selective membranes are positioned e Continuously regenerates automatically between an anode and a cathode Layered ion exchange resin beds and concentrate chambers are alternately positioned Limitations e Limited capacity feed water must be of high quality between them On applying an electric voltage water H 0 is split into H and e Does not remove organics particles pyrogens OH in the cell The H and Na cations can migrate through the or bacteria cation permeable membranes anions through the anion permeable membranes Systems that utilize this technology e Barnstead LabTower EDI water purification system The ions migrate in the direction of the applied voltage i e anions to the positive pole anode cations to the negative pole cathode The water ions H and OH that migrate through an ion exchange chamber displa
45. atio of impurities removed to total impurities in the incoming feedwater For example RO membranes typically remove reject 90 of the dissolved inorganic contaminants in water Permeate In reverse osmosis the water that diffuses through the membrane thereby becoming purified water Pretreatment Initial water treatment steps performed prior to final processing to prolong the life of cartridges and filters and to protect downstream elements from premature failure Product Water The purified water produced as a result of treatment Pyrogens Lipopolysaccarides found in the outer cell walls of certain bacteria which can trigger an immune response Recirculation Continuous recirculation may be necessary to maintain uniformly high purity in larger water systems Water is continuously recirculated and reprocessed to prevent stagnation and to rinse out residual impurities in the system Bacteria flourish in stagnant water Reject In reverse osmosis and ultrafiltration those impurities not able to permeate the membrane are said to be rejected removed They are flushed away in the reject waste stream Resin lon exchange resins are usually bead like spherical materials with an affinity for particular ions Cation exchange resins made of styrene and divinylbenzene containing sulfonic acid groups will exchange hydrogen ions for any cations they encounter Similarly anion exchange resins made of styrene and
46. ation system e Thermo Scientific Barnstead GenPure water purification system e Thermo Scientific Barnstead MicroPure water purification system e Thermo Scientific Barnstead E Pure water purification system The ultrapure systems differ in their features and daily volume output so please see the Type 1 Section for complete information Barnstead Smart2Pure water purification system Pure Type 2 Water Type 2 water is most widely used in general laboratory applications such as reagent preparation and glassware rinsing It is also commonly used to feed our Type 1 systems to create a comprehensive water system The below systems provide you with the Type 2 water you need for your applications e Thermo Scientific Barnstead Pacific TII water purification system e Thermo Scientific Barnstead LabTower TII water purification system e Thermo Scientific Barnstead Mega Pure Glass Stills water purification system e Thermo Scientific Barnstead Classic Stills water purification system Reverse Osmosis RO Water RO is a percent removal technology thus the purity of the product water is directly dependent on the quality of the feed water Accordingly it can not be generally classified as a specific type of water RO water is recommended for use in general laboratory equipment such as the sterilizer dishwasher and water baths The below systems provide you with the RO water you need for your applications e T
47. bon H20 Free of Chlorine and Some Organics Cl TN 44 b 990 Cl l gt e d Feed water with organic and chlorine contaminants come into contact with the activated carbon in the cartridge The impurities adhere to the surface of the carbon allowing purified water to be produced A D _A Ultraviolet UV Oxidation Photochemical oxidation with ultraviolet light eliminates trace organics and inactivates microorganisms in feed water The UV lamps in our pure water systems generate light at two wavelengths 185 and 254 nm The light generated at 254 nm has the greatest anti bacterial action reacting with their DNA resulting in inactivation The combination 185 254 nm light oxidizes organic compounds allowing for total oxidizable carbon levels of less than 5 ppb Benefits e Effective method to prevent bacterial contamination e Oxidizes organics to produce pure water with low TOC levels Limitations e Will not remove ions colloids and particulates Systems that utilize this technology e Barnstead GenPure MicroPure LabTower EDI Smart2Pure Pacific TII Lab Tower TII water purification systems Combination Ultraviolet Oxidation and Ultrafiltration UV UF The use of ultraviolet oxidation and ultrafiltration technologies in conjunction with adsorption and deionization in the same system produces water virtually free of all impurities These technologies have demonstrated the ability to remove nucleas
48. ccessories e Pretreatment Choose the cartridge based on Resin Model e Deionization your application needs Type s four Number Anion removal Strong Effective removal of weakly ionized impurities raises Anion the pH of solutions recovers precious metal complex Exchange Cation removal Sn Converts ionized salts to the acid form resulting in Cation 3170 grains D0815 a product water that is low in pH ideal for precious l Exchange metal or isotope recovery High capacity Removes ionized impurities produces a larger Two Bed lon quantity of water than that of the Ultrapure D0809 Exchange MOU Gene Heats however at a lower resistivity Ultrapure Removes ionized impurities to produce highest Mixed Bed 875 grains D0809 resistivity water with a neutral pH Ultrapure and organic removal pretreatment e Organic and chlorine removal 1680 grains D0760 Mixed Bed Commonly used as still pretreatment Removes re 785 grains D0832 a ionized impurities and has a layer of activated carbon Cabon 1000 gal to remove chlorine and organics _ V i gani fd i Thermo Scientific Barnstead Hose Nipple Cartridges The Barnstead Hose Nipple Cartridges are an economical way to purify water volumes up to 75 L hr Applications include softening deionization organic and chlorine removal SE LIeIt Lavo e Economical purification option Fa e ideal for small volume applications e Same superior quality
49. ce salt ions retained by the ion exchanger resins and so continually regenerate the resins The salt ions migrate through the appropriate ion selective membranes into the concentrate chambers and are flushed out of them by water As all concentration chambers are flushed through one after the other excess H and OH ions can again combine to form H30 www thermoscientific com purewater 11 Adsorption Adsorption uses high surface area activated carbon to remove organics and chlorine from feed water It is used as a first or second step in most water purification systems and may be used as a final step in combination with ion exchange resins to achieve ultra low Total Organic Carbon TOC Organics and chlorine adhere to the surface of the activated carbon and remain attached to the carbon Mixed bed deionization and adsorption We use a combination semiconductor grade mixed bed deionization resins and synthetic carbon in a single cartridge to achieve maximum resistivity and low Total Organic Carbon TOC Benefits e Removes dissolved organics and chlorine e Long life Limitations e Will not remove ions and particulates Systems that utilize this technology e Barnstead GenPure MicroPure E Pure LabTower EDI Smart2Pure Pacific TII LabTower TII and the Bantam water purification systems Hose Nipple and B Pure cartridges au Selection of high quality resins used in our cartridges Chlorinated H20 Car
50. d e Does not remove dissolved gases e Requires pretreatment to avoid damaging the membrane gt Oxidation Chlorine gt Scaling CaCO gt Fouling Organics and Colloids gt Piercing Hard particles Pacific RO and Lab Tower RO water systems Systems that utilize this technology e Thermo Scientific Barnstead Smart2Pure LabTower EDI Pacific TII LabTower TII Pacific RO LabTower RO water purification systems www thermoscientific com purewater 9 Deionization Deionization is also referred to as demineralization or ion exchange The process removes ions from feed water with the use of synthetic resins These resins are chemically altered to have an affinity for dissolved inorganic ions and are divided into two classifications cation removal resins and anion removal resins Cations have a positive charge and include sodium Na calcium Ca and magnesium Mg Anions have a negative charge and include chloride CF sulfates 60 and bicarbonates HCO The ions are removed from the water through a series of chemical reactions These reactions take place as the water passes through the ion exchange resin beds Cation resin contains hydrogen H ions on the surface which are exchanged for positively charged ions Anion resin contains hydroxide 0H ions on its exchange sites which are exchanged for negatively charged ions The final product of these two exchanges is H and OH which combine to form
51. dges and a 10 inch filter housing Both are required for complete pretreatment solution um filter with a 10 inch filter housings 09 4003 Sterile vent filter for reservoir Sterile overflow for reservoir Optional Accessories 06 5003 90132714 Printer Utilizes 110V AY1137X1 RS 232 interface for safe documentation of all measured values and faults with date and time in compliance with GLP guidelines 230V 09 2207 Water watcher Alerts the user to leaks Available as 240V only Replacement Consumables Reverse Osmosis membrane LabTower TII 20 and 40 require two membranes as indicated 10 5um filter with hardness stabilizer cartridge Replacement reservoir UV Lamp 230V only UV lamp assembly for the reservoir with lamp 230V only 06 5006 16 0129 22 0046 must order 2 06 5204 09 5002 Europe Asia Pacific 09 2202 Cleaning solution p e e Eww ther scientific com purewater North America CMX25 from an integrated system Feed Water Requirements Temperature 2 35 C LabTower RO 40 90132391 90134022 09 4003 06 5003 90132714 AY1137X1 09 2207 06 5006 16 0129 22 0087 must order 2 06 5204 09 5002 09 2202 CMX25 CE SWALSAS OH SW JS S UONeONUNd 1978M 3Nd Thermo Scientific Barnstead Pacific RO water purification systems The Barnstead Pacific RO system is a modularly designed laboratory reverse osmosis system specifica
52. divinylbenzene containing quaternary ammonium groups will exchange a hydroxyl ion for any anions Resistivity A measure of specific resistance to the flow of electricity In water it is an accurate measure of ionic purity See Megohm cm Reverse Osmosis The reversal of osmosis to purify water In osmosis water diffuses through a semipermeable membrane from a less concentrated solution to a more concentrated solution The flow of water can be reversed with an opposing pressure that exceeds osmotic pressure With Reverse Osmosis water is forced out of a concentrated solution leaving the solute impurities behind www thermoscientific com purewater 111 Q O N oO gt JJ lt Salt Rejection In reverse osmosis the ratio of salts removed rejected to the original salt concentration See Percent Rejection Scale The mineral deposits that can coat the insides of boilers or the surfaces of RO membranes It consists mainly of calcium carbonate which precipitates out of solution under certain conditions of pH alkalinity and hardness Semipermeable Membranes that do not have measurable pores but through which smaller molecules can pass Suspended Solids Undissolved solids that can be removed by filtration TDS Abbreviation for total dissolved solids Total lonized Solids Concentration of dissolved ions in solution expressed in concentration units of NaCl sodium chloride Total O
53. er Pacific TII reservoirs e Store high purity water safely and conveniently Large opening e For easy and effective cleaning by hand Optional safety filters e A CO absorber prevents conductivity increases from drawn in CO e Sterile overflow prevents microorganisms from entering and contaminating reservoir water Polyethylene reservoir e Constructed with inert materials opaque to light Recirculation pump e Recirculation pump protects high purity water from bacterial growth during standstill while maintaining a low conductivity value Wall mount e Simple and space efficient wall mounting Conical bottom outlet e Allows complete draining and efficient cleaning and disinfection Specifications and Ordering Information Feed Water Specifications Source and pre treatment Tap water softened or hardness stabilized Conductivity uS cm lt 1500 Free chlorine concentration mg L 01 pH Range 4 11 Temperature C 2 35 C Pressure psi bar 29 87 2 6 complete list of feed water specifications can be found in the operational manual Pacific TII System Feed water Dimensions Ambient Operating pressure Electrical requirements Power consumption connector WxDxH temperature 29 87 psi 90 240V 14 6 x 13 x 23 7 in 2 6 bar 50 60Hz See a 372 x 330 x 603 mm Storage Reservoir Volume Material Dimensions 30 L 23 5 x 14 9 in 598 x 380 mm 60 L Polyethylene ultrapure water resistant 35 9 x 14
54. eration e HPLC e GC GC MS ICP MS AA e TOC Measurements IC GLP compliant documentation e Real time clock and code protected operating system prevents unauthorized changes to system settings RS 232 interface with adjustable send interval for safe data transfer of all measured data faults date and time to a PC computer or log printer Digital microprocessor control automatically monitors and stores faults from the last four weeks USP compliant conductivity measurement with temperature compensation can be switched on or off Tilting control panels for easy viewing e Ergonomically designed controller tilts for optimal key pressing and easy readability e lluminated four line alpha numeric display 34 Quick Look Comparison Chemical analysis trace analysis HPLC ICP MS IC monoclonal antibodies HPLC IC ICP MS TOC analysis cell culture media TOC measurements Resistance at 25 C TOC monitor n a n a n a Flow rate L min Molecular biology PCR DNA Inorganic and organic trace analysis Microbiology IVF monoclonal antibodies AA IC ICP Applications standard buffer www thermoscientific com purewater Biosciences cell and tissue culture media PCR DNA monoclonal antibodies 18 2 0 055 1 5 lt 1 lt 1 lt 0 001 standard Up to 2 39 ab CO gp fab qu U s aP o mr op
55. ermo Scientific Barnstead Pacific RO and Thermo Scientific Barnstead LabTower RO systems have pretreatment solutions to prevent this Included in the pretreatment system is a hardness stabilizer cartridge which binds calcium thereby protecting the RO membrane Chlorine Chlorine can damage the RO membrane and reduce its performance and useful life Again both Pacific RO and LabTower RO have solutions to pretreat the water which includes a 5 um prefilter activated carbon cartridge to prevent entry of particles gt 5 um and high concentrations of free chlorine Turbidity The turbidity level indicates the amount of suspended solids present This suspended material can shorten the life of filters and reverse osmosis membranes if not removed Our Pure Water Experts can recommend pretreatment options if turbidity is an issue with your feed water RO membranes show very little fouling when the feed water has a turbidity of less than 1 NTU SDI Silt Density Index Suspended solids and colloidal materials in feed water are one of the biggest problems in reverse osmosis systems In order to have some measure of the degree of this fouling problem a concept called Silt Density Index is used Here a 0 45 um filter is exposed to the feed water under pressure and filtration rates are calculated A SDI of lt 5 is considered acceptable for the reverse osmosis systems www thermoscientific com purewater O 77 Therm lentific Barnst
56. es such as RNase and DNase as well as pyrogens when challenged with known concentrations of the material The Type 1 systems with UV UF options produce reagent grade water with resistivity up to 18 2 MQ cm TOC of 1 5 ppb pyrogens lt 0 001 EU ml and no detectable RNase DNase or DNA Benefits e Removes nucleases and DNA e Produces water with low TOC and pyrogen levels Limitations e Must be used in the same system Systems that utilize this technology e Barnstead GenPure MicroPure and Smart2Pure water purification systems www thermoscientific com purewater 13 What does Type 1 water mean Reagent water has quantitative specifications that describe the level of purity for the water These specifications have been described by ASTM American Society for Testing and Materials D1193 ISO International Organization for Standardization 3696 and CLSI CLRW Clinical and Laboratory Standards Institute Clinical Laboratory Reagent Water The most commonly used standards ASTM D1193 6 are summarized in the tables below ASTM Standards for Reagent Water Measurement unit Type Type Il Type Ill Resistivity MQ cm at 25 C gt 18 gt gt 4 Total organic carbon ppb lt 50 lt 50 lt 200 Sodium ppb lt lt 5 lt 10 Chloride ppb lt lt 5 lt 10 lt 3 lt 500 Total silica ppb Zg The ASTM standards are further subdivided into A B and C These standards can be used in conjunction with the Type of water AS
57. etreatment cartridge ultrapure polisher cartridge sterile 0 2 um filter pressure regulator UV lamp and or UF filter where applicable The 3 and 6 Iph models also include an internal 6L tank with vent filter Required Accessories Pretreatment filter Required to prolong cartridge life Ships with a filter housing and 1um filter Optional Accessories Wall mounting bracket Qualification documents 1000 Replacement Consumables RO membrane with integrated pretreatment Ultrapure polisher cartridge Sterile 0 2 um filter for system Ultrafilter System UV lamp Cleaning solution Smart2Pure System 12 L hr systems include an RO pretreatment cartridge an ultrapure polisher ils 90 240V 50 60Hz 0 06kW 1 4 in o d 2 6 bar Electrical Feed water Dimensions requirements RUE SECU ISIN connector W x D x H in mm 12 x 15 7 x 21 5 305 x 400 x 545 3 L hr 50129869 50129872 50129870 50129688 6 L hr 50129873 90129885 50129874 50129887 09 4003 09 4003 09 4003 09 4003 09 2212 09 2212 09 2212 09 2212 IOQDOCE50133911 IOQDOCE50133911 IOQDOCE50133911 IOQDOCE50133911 n a n a 09 1002 09 1002 Europe Asia Pacific 09 2202 09 2202 09 2202 09 2202 North America CMX25 CMX25 CMX25 CMX25 cartridge sterile 0 2 um filter pressure regulator UV lamp and or UF filter where applicable Required Accessories Smart2Pure Reservoir Choose a reservoir that fits your needs Pretreatment filter Required to prolong cartr
58. f TOC is done using an in line system Speaking the Language of Pure Water Water full of ions Pure water has very will conduct few ions so it does not electricity well conduct electricity well f conduct Resistivity Conductivity resistivity Conductivity and Resistivity Electrical conductance or resistance is measured by two in line electrodes Electrical current moves through water using ionic molecules as stepping stones The fewer stepping stones the more difficult the passage of electricity This causes less electrical conductance and more electrical resistance The temperature of the water also affects the conductivity resistivity so readings are usually normalized to 25 C via temperature compensation We use resistivity to measure ion concentration in pure water We understand water and realize that in order to achieve Type 1 water meeting the most stringent requirements of our customers multiple technologies must be used speaking the Language of Pure Water When designing your water system we suggest you take time to evaluate the applications and interest areas of the lab now and in the future Take a look at the table below to determine what type s of water you need General Lab Purpose Autoclave Glassware washing rinsing O i General lab equipment water baths incubators etc cc o o Feed water to Type 1 systems ia Buffer prep TS Chemical and biochemical reagent prep O llr Analytical
59. ges to complete your system D440066 Dimensions W x H x D 16 75 x 25 5 x 7 5 in 42 6 x 64 8 x 19 cm Still adapter kit Required to connect the Deionization System to any Mega Pure Glass Still elie Deionizer accessories Solenoid valve accessory kit For use with the D1 or D2 when used as stand alone units 440375 High purity cartridge Used in the MP 12A D1 and D2 unit for high purity High capacity cartridge Used in MP 12A D1 and D2 Removes ionized solids for extended capacity D400377 Deionization cartridges D400499 Organic removal cartridge Used in D2 for organic and chlorine removal D440265 Volume Output for 208V units can be reduced up to 25 less than specified T 66 Storage Options Plastic bottle 6 L capacity For use with MP 1 and MP 3A stills Glass bottle 9 L capacity Storage bottles For use with MP 1 and MP 3A stills For manual operation Glass bottle 13 L capacity For use with any Mega Pure Glass Still Glass bottle 45 L capacity For use with any Mega Pure Glass Still Automatic collection system ACS unit Automatic collection system ACS Flexible tubing adapter kit For use with any Mega Pure Glass Still Needed when the supplied glass tubing is either too long or too short to reach still Flexible Collects up to 45 L of water and controls the still tubing is not included 0 5 inch Teflon tubing able to handle 80 90 C water is recommended Dimensions W x H x D 16 25 x 38 x 16 25 in 41
60. h space exists Allows for fast and simple cartridge change outs Si Economical Filter Holder B pure B pure B Pure Double Holder Single Holder Half Size Holder alay Uie Hose Nipple Bantam Deionizer Expanded purification with full features Smaller Complete system Economical Simple system for Complete capacity for with dispenser choice for nonpressurized nonpressurized optimal value and cartridge particle filtration applications system Single step purification Requires v v v v pea v v 7 4 7 4 4 2 4 2 0 75 0 63 www thermoscientific com purewater 95 Thermo Scientific Barnstead B Pure water system The Barnstead B Pure is an economical laboratory grade water system with flow rates up to 4 L min that can be customized to meet your specific applications Choose from single or double holders depending on your application needs e Customize your water system to meet your application needs Modular design provides the ability to add additional holders when the need arises e Produces up to four L min e Quarter turn quick release canisters make changing cartridges simple e Accepts Thermo Scientific Barnstead Pura Lite purity indicator or digital purity meter to monitor water quality e Available in full or half size cartridge configurations supporting space constraints Single holder e Produces up to four L min e Simple system without a draw off valve or purity indicator Double holder e Produces
61. he built in 100 L reservoir has a conical bottom outlet to optimize cleaning and sanitization RO membrane removes up to 99 of impurities All remaining ions are removed by the low TOC high purity resins in the ion exchange cartridge Irradiation with UV light TII units with UV option only eliminates any bacteria or germs that are present www thermoscientific com put 3 E 5 LE Specifications and Ordering Information Feed Water Specifications Source Potable tap water softened or hardness stabilized lt 3 with higher values an upstream pretreatment Pocking Maak OPH model no 09 4000 is to be installed Conductivity pS cm lt 1500 Prefiltration 5 um activated carbon hardness stabilization Free chlorine mg L 0 Colloid index lt 3 ph Range 4 11 Temperature C 2 35 Pressure psi bar 29 87 2 6 complete list of feed water specifications can be found in the operational manual LabTower TII Operating Electrical Feed water Dimensions Ambient pressure requirements SO TE Ge G connector W x D x H in mm temperature 29 87 psi 90 240V 17 7 x 22 8 x 59 2 6 bar 50 60Hz ene R 3 4 in 450 x 580 x 1500 2 85 C LabTower Lab Tower System Options UV option TII 20 TII 40 U F qp o qe x U E qp o Sp lt ep 4 OO LabTower TII Systems All systems include an RO membrane a high purit
62. he natural osmotic flow This forces the feed water through the semipermeable membrane The impurities are deposited on the membrane surface and sent to drain and the water that passes through the membrane as product water x is for the most part free of impurities Saline Solution Semipermeable Membrane To Drain A reverse osmosis membrane has a thin microporous surface that rejects impurities but allows water to pass through The membrane rejects bacteria Process of reverse osmosis pyrogens and 90 95 of inorganic solids Polyvalent ions are rejected easier than monovalent ions Organic solids with a molecular weight greater than 200 Daltons are rejected by the membrane but dissolved gases are not as effectively removed Reverse osmosis is a percent rejection technology The purity of the product water depends on the purity of the feed water The product is typically 95 99 higher in purity than that of the feed water Due to the restrictive nature of the membrane the flow rate is much slower than other purification technologies This slow flow rate means that all RO systems require a storage reservoir to provide a constant supply of RO water ready when you need it Benefits e To varying degrees removes most types of contaminants bacteria pyrogens and 90 95 of inorganic ions e Requires minimal maintenance Limitations e Limited flow rates through the membrane require intermediate storage devices to meet user deman
63. hen lamp changes are necessary only the lamp needs to be removed The reservoir cover and sheath remain in place eliminating any exposure of water to contamination from the air Specifications and Ordering Information System Options Overall dimensions in cm Reservoir options Distribution outlet NPT Drain outlet NPT Model number D 35 89 B3047 89 200 gal 1 1 2 in um 38 96 50 128 45 114 B3049 2 SU9 JS S UONPIIUNd 139 8M Bund For the 10 gal reservoir 11 28 27 69 11 28 H1000 For the 25 gal reservoir 19 48 27 69 19 48 H1001 Mounting options Floor stands For the 50 gal reservoir 22 56 20 51 22 56 H1002 aint es ae For the 100 gal reservoir 29 74 11 Required Accessories ge Come ey 28 29 74 H1003 your needs For the 200 gal reservoir 39 99 22 56 39 99 H3230 For the 10 For the 10 gal reservoir reservoir H3240 Wall brackets Kok l the 25 gal reservoir H3242 UV light assembly H4005 Maintains water sterility in reservoir Includes housing on off switch 6 ft cord lamp and ballast Ventgard air filter and water seal H3111 Replacement Consumables Replacement UV lamp 04141 Ventgard air filter H3120 Protects stored water against airborne particulates organics and CO Replacement water seal eT H3130 Prevents air from entering storage reservoirs via condenser atmospheric vent Ventgard filter element 25001 DB The consumable portion
64. hermo Scientific Barnstead Pacific RO water systems e Thermo Scientific Barnstead LabTower RO water systems Barnstead GenPure xCAD water purification system Cartridge and Filter Systems Cartridges are a great option for laboratories either needing point of use polishing of pretreated water or single state treatment of tap water The below cartridge and filter systems are available for your specific application needs e Thermo Scientific Barnstead B Pure water system e Thermo Scientific Barnstead Hose nipple cartridges e Thermo Scientific Barnstead Bantam deionizer e Thermo Scientific Barnstead 1 2 Size B Pure filters Barnstead Hose Nipple Cartridge and Holder Barnstead B Pure Cartridge Holder www thermoscientific com purewater Barnstead Bantam Deionizer 19 20 Pretreatment Barnstead Pacific TIl 30 L Polyethylene Barnstead GenPure xCAD UV UF water purification system Reservoir water purification system m r Y a Tap water i Type 2 water RO reservoir flows into water feeds the reservoir the Barnstead RO Water GenPure Type 1 Water Cell and Tissue Culture PCR Media Prep and HPLC Water Type s Needed Type 1 low organics pyrogens and nucleases and Type 2 water Applications in the Lab Solution Barnstead Pacific TII 30 L reservoir and Barnstead GenPure xCAD UV UF The Watson Lab is a traditional cell and molecular biology lab so they needed a system
65. hos cm Deionization Removing dissolved ions from solution by passing it through a bed of ion exchange resins consisting of polymer beads that exchange hydrogen ions for cations and hydroxyl ions for anions in solution The ionic impurities remain bound to the resins and the hydrogen and hydroxyl ions combine with each other to form water Dissolved Solids Also referred to as Total Dissolved Solids TDS it is the amount of nonvolatile matter dissolved in a water sample and is usually expressed in parts per million by weight Distillation The process of separating water from impurities by heating until it changes into vapor and then cooling the vapor to condense it into purified water Electrodeionization EDI Removes dissolved ions from solution using electricity to ionize water and separate ions Effluent The output or discharge from a water treatment process Endotoxin poisonous substance present in bacteria that is released when the cell disintegrates In water treatment it most often refers to pyrogens Exhaustion When absorbents such as activated carbon or ion exchange resins have depleted their capacity by using up all active sites lon exchange resins may be regenerated to reverse the process Feed Water Water entering a treatment process Filtration Removal of suspended matter by passing it through a porous matrix that prevents particles from getting through usually by entra
66. ia 56 Multiple options for Type 2 water e Five system options with permeate flows of 3 7 12 20 or 40 L hr e Future system upgrades accommodate greater capacities to meet growing water demands e Space saving design permits benchtop installation or wall mounting with integrated mounting bracket Operational reliability e Microprocessor controlled for automatic operation with continuous monitoring of all critical parameters e Automatic return to operating mode ensures recirculation during standstill periods e Optional UV lamp prevents biological contamination Easy to operate e Resistivity conductivity clearly displayed on large back lit control panel that tilts for optimum viewing e Status of current operating mode clearly indicating production stand by cleaning or disinfection modes e Reservoir fill level shown as e System parameters are code protected to prevent accidental changes to set points GLP Compliant documentation e Optional printer connects to RS 232 port for data recording and traceability e Cell constant of 0 01cm ensures precise conductivity measurements e Temperature compensation for the conductivity measurement has an accuracy of 0 1 C in conformity with USP 645 Volume display e Water level in reservoir is shown automatically on the Pacific TII display Clear information Large illuminated four line display is easy to read and provides information on
67. iance 230V 09 2207 09 2207 09 2207 09 2207 09 2207 09 2207 Qualification Documentation IQ0Q I0QDOCE50133919 I0QDOCE50133919 I0OQDOCE50133919 I0QDOCE50133919 OQDOCES0133919 I0QDOCE50133919 Storage reservoir 30 L to feed system Polyethylene tank opaque to light 23 5 x 14 9 in 598 x 380 mm H x W 06 5038 06 5038 06 5038 06 5038 06 5038 06 5038 Wall mount accessory is 06 5015 Storage reservoir 60 L to feed system Polyethylene tank opaque to light 35 9 x 14 9 in 912 x 380 mm Hx W 06 5068 06 5068 06 5068 06 5068 06 5068 06 5068 Wall mount accessory is 06 5016 Disinfection cartridge 09 2201 09 2201 09 2201 09 2201 09 2201 09 2201 Replacement Consumables Ultrapure polisher cartridge 09 2005 09 2005 09 2005 09 2005 09 2005 09 2005 Sterile filter 0 2 um 09 1003 09 1003 09 1003 09 1003 09 1003 09 1003 System Options Ultrafilter ma 50133980 50133980 50133980 UV lamp 09 2002 oe 09 2002 09 2002 09 2002 Europe 09 2202 09 2202 09 2202 09 2202 09 2202 09 2202 Asia Pacific Cleaning solution North America CMX25 CMX25 CMX25 CMX25 CMX25 CMX25 CE www thermoscientific com purewater 33 pe TD x cD o qe U s CD o O WM lt op qe O Thermo Scientific Barnstead GenPure water purification system The Barnstead GenPure system delivers ultrapure 18 2 MQ cm water with consistent quality for the most demanding and sensitive applications
68. idge life Ships with a 10 inch filter housing and 1 um filter Optional Accessories Wall mounting bracket for the system Qualification documents 1Q0Q See Storage Reservoir Options 09 4003 09 4003 09 4003 09 4003 092212 09 2212 09 2212 09 2212 IOQDOCE50133912 IOQDOCE50133912 IOQDOCE50133912 I0QDOCE50133912 Replacement Consumables RO membrane with integrated pretreatment Ultrapure polisher cartridge Sterile 0 2 um filter for system System UV lamp Ultrafilter Cleaning solution 50133981 50133981 www thermoscientific com purewater 90129888 90129890 50129889 90129845 CE G 8 AdAL Cc pe Le CD o cD U C2 fab nr Sp lt Sp qe 3 ON TY gt P pure water purification systems Pure water for a wide range of applications Type 2 pure water is an essential part of creating consistently pure chemical reagents microbiological buffers and media Type 2 water is also recommended as a pretreatment for Type 1 ultrapure systems Innovation Advanced feed water monitoring alerts user to fluctuations in feed water quality to optimize cartridge convenience Aquastop connections allow users to quickly change the cartridge and minimize downtime flexibility Gain more space with numerous installation options on the bench wall or standalone www thermoscientific com pu
69. ies of 3 6 or 12 L hr Lasting economy e Water purification progresses through independent cartridges with Aquastop quick connect for fast replacement Module 1 Combination of pretreatment and the reverse osmosis membrane Module 2 Polishing cartridge contains high quality ultrapure resin for consistent purity and long cartridge life Easy to operate e Dispensing is easy and features variable speed to control flow e The display can be tilted for optimal reading e Optional UV bulb and ultrafilter to customize ultrapure water quality Placement options e Position on laboratory bench e Mount it on the wall Smart2Pure 3 and 6 features smart integrated 6 L reservoir e Constructed with pigment free materials e Conical bottom outlet allows for complete draining and efficient cleaning and Molecular Biology and Microbiology disinfection e Cell and tissue culture Smart2Pure 12 offers reservoir options either 30 or 60L e Large opening for easy and effective cleaning by hand e Sterile venting filter reservoir overflow protects against contamination by microorganisms Optional CO absorber prevents TOC value increases from drawn in CO e Polyethylene reservoir is opaque to light e Recirculation pump protects the high purity water from bacterial growth during standstills and maintains the low conductivity value e Wall mount optional for simple space savings e Conical bottom outlet allows for complete draining and efficient cleaning
70. ing virgin polypropylene to allow for easy recycling after end of life The cartridge is assembled in a clean environment using environmentally friendly ultrasonic welding that minimizes energy usage compared to other joining as well as avoids the use of any environmentally unfriendly solvents Our conscious effort to avoid chemical solvents and adhesives makes the plastic and resin suitable to be recovered reground and reused for a variety of alternate uses 108 Common Conversions Common Conversions for Pure Water 1 U S Gallon gal 231 Cubic in in 3 785 Liters L Volume 1 Cubic Meter m 35 3 Cubic Feet ft 3 1 U S Ounce 0z 29 57 Milliliters mL 1 U S Gallon gal 8 33 Ib Water 1 Cubic Foot ft 3 62 3 Ib Water F C x 9 5 32 Temperature K C 273 F K 273 15 9 5 32 1 Ib 453 6 grams g 7000 grains gr 1 kg 2 205 Ib 1 Atmosphere 14 7 Pounds Per Square Inch psi 101 325 Kilo Pascal KPa psia absolute psig gauge 14 7 Pressure 9 92 in Hg 33 83 ft H 0 1 kg cm 14 233 psi 1 KPa 0 145 psi 1 Grain Per Gallon gr gal 17 1 Parts Per Million ppm U U O JJ gt Z g Ma m gt Z m Density Mass 1 Grain Per Gallon as NaCl 0 85 Grains Per Gallon as CaCO 1 Part Per Million ppm 1 Milligram Per Liter mg L Total ionized solids concentration 1 ppm as NaCl 0 85 ppm as CaCO 1ppm 1 000 Parts Per Billion
71. ion dates Deioization ee tion Filtration aria Adsorption wy cE Oe om p 2 nr Nucleases ra gt gt nn DG D GG g eie ons D gt a Speaking the Language of Pure Water Thermometer Receiver Condenser Distillate Heat Source A basic distillation diagram Distillation Distillation has the broadest removal capabilities of any single form of water purification Water is boiled and undergoes phase changes during the distillation process changing from liquid to vapor and back to liquid It is the change from liquid to vapor that separates the water in various degrees from many dissolved impurities such as ions organic contaminants with low boiling points lt 100 C bacteria pyrogens and particulates Distillation can not be used on its own to remove inorganic ions ionized gases organics with boiling points higher than 100 C or dissolved non ionized gases Benefits e Offers the broadest removal capabilities of any single form of water purification Classic Stills e Requires no consumables Limitations e Requires periodic maintenance and manual cleaning of system to maintain water purity e Requires water for cooling Systems that utilize this technology ss e Thermo Scientific Barnstead Classic Stills and Mega Pure Stills www thermoscientific com purewater 7 Filtration Barnstead water purification products offer both depth no
72. ionizer D2 www thermoscientific com purewater 65 Thermo Scientific Barnstead Mega Pure Glass Stills continued Specifications and Ordering Information Product Specifications Inlet water temperature C F Vent temperature C F Auto drain Inlet pressure psig Auto start stop controls 4 37 39 2 98 6 85 96 7 185 206 PND 20 100 System Options Ho Ouerallidimenelons Electrical 50 60 Hz Model number W x Hx D in mm Volts Unit 6 L bottle included L hr 18 x 34 x 9 75 120 4 A440266 A440267 45 7 x 86 4 x 24 8 A NER cee MP 1 MP 3A 2i 58 4 x 114 3 x 30 5 PP 23x45x12 as dE 29 2 x 53 x 14 4 oul A440118 E Model Number 4402362 MP 11A MP 12A Built in deionizer holds two cartridges and distillate cooler Required Accessories Dual solenoid MP 1 240V MP 3 MP 6A and MP 11A Required if using pretreated boiler feed water and untreated cooling water MP 1 120V RY798X2A Deionization cartridges Required for MP 12A See Optional Accessories Storage solutions see Storage Options Optional Accessories Model Number Single cartridge deionizer D1 single cartridge deionizer removes inorganic contaminants Order one deionization cartridge to complete your system D440046 Dimensions W x H x D 10 5 x 25 5 x 7 5 in 26 7 x 64 8 x 19 cm Dual cartridge deionizer D2 Provides increased capacity with chlorine and organic removal Order two deionization cartrid
73. ions 30 L 23 5 x 14 9 in 598 x 380 mm Polyethylene opague to light 60 L 35 9 x 14 9 in 912 x 380 mm Pacific RO Product Specifications Dimensions WxDxH Operating pressure psi bar Electrical requirements Power consumption Feed water connector Temperature 90 240 V 50 60Hz 14 6 x 13 x 23 7 in 372 x 330 x 603 mm R 3 4 in 2 35 C Pacific RO 3 Pacific RO 7 Pacific RO 12 Pacific RO 20 Pacific RO 40 Ordering Table Pacific RO Systems All systems have an integrated wall bracket and include an 50132385 50132386 50132387 50132388 50132389 RO membrane and pressure regulator Required Accessories Pacific RO Pretreatment Includes two 10 inch 25 4 cm cartridge housings a 5 um prefilter 09 4000 09 4000 09 4000 09 4000 09 4000 activated carbon cartridge and hardness stabilizer cartridge Pacific RO Reservoir Choose a reservoir that fits your needs See Storage Reservoir Options the next page Optional Accessories Water watcher Alerts the user to leaks Available as 230V only re JEUNES 16 0123 16 0123 16 0123 Replacement Consumables Reverse Osmosis membrane Pacific RO 3 7 12 only require a single RO membrane 22 0046 22 0046 22 0046 nes rite Pacific RO 20 and 40 require two membranes as indicated 5 uM prefilter actived carbon 10 inch cartridge 06 5201 06 5201 06 5201 06 5201 06 5201 Hardness stabilizing 10 inch cartridge 06 5452 06 5452 06 5452 06 5452 06 5452 Euro
74. itivity instrumental Molecular biology PCR Microbiology molecular Applications methods such as analytical methods such as DNA cell culture biology PCR DNA monoclonal AAS IC ICP HPLC ICP MS TOC analyses monoclonal antibodies antibodies cell culture media Endotoxines EU mL n a n a lt 0 001 SW JS S UONCDIUN 1818M 91nde1N 18 2 MQ cm water in a compact system c com purewater 39 Thermo Scientific Barnstead MicroPure water purification system continued Dispense water which allows for drop by One two three The MicroPure ST series includes an drop or quick dispensing optional 6 L feed water reservoir for Rapid cartridge change with pretreated water storage Aquastop Quick connect design 40 Feed Water Requirements Source Potable tap water pretreated by reverse osmosis ion exchange or distillation Feed water conductivity pS cm lt 5 TOC ppb max 50 Turbidity NTU lt 1 0 Temperature C 2 35 Pressure psi bar 1 4 87 0 1 6 Please see user manual for complete list of feed water requirements Product Specifications Dimensions Dimensions Operating pressure Electrical Power Feed water MicroPure no reservoir MicroPure ST Flow rate min max requirements consumption connector WxDxH in mm WxDxH in mm 29 87 psi 12 x 11 8 x 21 5 12 x 15 7 x 21 5 up to 1 5 L min 2 6 bar 90 240 V 50 60Hz 0 06kW 305 x 300 x 545 305 x 400 x 545 System Options Micr
75. ity as CaCO 1680 grains 3170 grains 1760 grains 2000 gal D0836 5000 gal D0813 5000 gal D50215 5000 gal D63112 18g D50214 275 grains 9 g D50216 875 grains D0809 D50213 785 grains 1000 gal D0832 275 grains 2000 gal D50217 455 grains 30 g D8809 365 grains 2000 gal 12 g D8811 on O1 S Q a 5 D Voltage N 99 SWAI SAS SJaqI4 Thermo Scientific Bantam Deionizer The Bantam Deionizer is an economical way to deionize your water Easily view resistivity readings directly from unit Customizable to specific applications by selecting the appropriate cartridge listed below LS 4 g e ideal for applications requiring up to 38 L hr of purified water e Select the cartridge to best meet your application needs e Point of use polishing of pretreated water or single stage treatment of tap water e Direct reading purity monitor e Designed for non pressurized applications Output water must be diverted to an atmospherically vented receptacle no back pressure can be accepted e Minimum inlet pressure 5 psi maximum inlet pressure 70 psi e Includes 3 ft 0 9 m of inlet feed tubing Quick Look Comparison Resistivity reading Flow rate 25 000 18 000 000 Q cm Up to 38 L hr System Options Overall dimensions Feed water Model WxHxD pressure ARE number Bantam 6 x 28 5 x 8 75in ae 120 VAC D0800 Deionizer 15 2 x 72 4 x 22 2 cm p a E Required A
76. lation in the reservoir moves water across a special polisher module ensuring fresh Type 2 water on demand High purity water reservoir outlet for convenient drainage Efficient cleaning and disinfection enhanced by conical bottom design for completely emptying reservoir Integrated reservoir provides 100 L of purified water storage Sterile vent filter and reservoir overflow prevents internal contamination by microorganisms from the surrounding air Optional CO absorber prevents CO adsorption into the water which would increase the TOC Highly visible reservoir volume display on LabTower controller e Customize volume stored in the reservoir via the controller www thermoscient with EDI te chnology Quickly view reservoir level volume in with highly visible continuous monitor C8 t AdAL SWA SAS UOIEIUNd Ja e sundesyy Thermo Scientific Barnstead LabTower EDI water purification system continued Cathon perneabhe 46 Purified water lt 0 1pSicm Electrolyte Concentrate Foedwater Pecneate fra RO system 4 I0 pSfon Technologies that keep you one step ahead e Constant high efficiency of the ion exchange layer bed produces consistently high quality water e No regeneration chemicals required and no disposal of cartridges making this technology friendly for the environment e No exchange of spent resins or cartridges saves cost e High purity water when you need it with no wait ti
77. lion ohms of resistance measured between two electrodes one centimeter apart The theoretical maximum ionic purity for water is 18 2 megohm cm at 25 C Membrane Filtration membranes are thin polymer films that are permeable to water and other fluids Microporous membrane filters have measurable pore structures which physically remove particles or microorganisms larger than pore size Ultrafiltration membranes sometimes called molecular sieves also remove molecules larger than a specified molecular weight Reverse osmosis membranes are permeable to water molecules and very little else rejecting even dissolved ions in water Mho Unit of measurement for conductance the reciprocal of ohm resistance See Megohm cm Mixed Bed lon Exchange Mixing both anion and cation resins in the same deionizer results in higher efficiency but lower capacity than separate bed deionizers NPT Abbreviation for National Pipe Thread Ohm The practical unit of electrical resistance in a circuit where a potential difference of one volt produces a current of one ampere Ohm cm Unit of specific resistance of water Osmosis The diffusion of a solvent through a semipermeable membrane from a less concentrated solution to a more concentrated solution Percent Recovery In reverse osmosis or ultrafiltration the ratio of pure water output to feedwater input Percent Rejection In reverse osmosis or ultrafiltration the r
78. lly developed for functional and economical production of high purity water Product Features e Five system options with permeate flows of 3 7 12 or 20 or 40 L h e Space saving design allows system to sit on the laboratory bench or be mounted on the wall e RO membrane removes organic and inorganic contaminants microorganisms particles and colloids e Simple system upgrade accommodates future pure water capacity requirements Reliable operation e Microprocessor control offers automatic operation with continual monitoring of all important parameters Easy to operate clear display e Resistivity conductivity clearly displayed on large back lit control panel that tilts for optimum viewing e Status of current operating mode clearly indicates production stand by or cleaning modes e Reservoir fill level shown as ROUTINE LABORATORY WORK Integrated feed water monitoring e Good quality feed water is a prerequisite for high purity water and extends e Rinsing lab glassware cartridge service life e Supplying autoclaves water baths GLP compliant documentation and incubators e Real time clock records system errors and faults er RAIN AG SIMON DURES ANU FERGENE e Ongoing data storage collects four weeks information displayed in clear text ener eran ieteeanerody e Operating system is code protected to prevent unauthorized changes to system settings RS 232 interface with adjustable sender inte
79. low paths and foul reverse osmosis membranes They typically range from 1 10 um in size Colloidal particles typically have a slightly net negative charge range in size from 0 01 1 0 um and can be either organic or inorganic Unlike suspended particles colloids do not settle out by gravity but remain suspended in the liquid that carries them Colloids clog filters interfere with instrument operation foul reverse osmosis membranes and can bypass ion exchange resins resulting in lower resistivity in deionized water systems Don t let impurities contaminate your sensitive experiments Thermo Scientific Barnstead water purification systems are engineered to remove impurities that threaten your research so you can focus on what s important your next discovery Impurities such as silicates chlorides fluorides bicarbonates sulfates phosphates nitrates and ferrous compounds are present as cations positively charge ions and anions negatively charged ions Water with a high concentration of ions will conduct electricity readily and have high conductivity and low resistivity as conductivity and resistivity are inversely related lons will adversely affect the results of inorganic analyses such as IC AA ICP MS and may retard cell and tissue growth in biological research They can also affect the cartridge life in deionized water systems Organic solids are present from plant and animal decay and fr
80. mbining purification with EDI technology and storage in one as well as producing both Type 1 and Type 2 water Stock high purity water safely and conveniently Type 1 Water Applications e Cell and tissue culture e PCR DNA sequencing e Electrophoresis TOC Measurements IC e HPLP GC MS ICP MS AA Type 2 Water Applications e Rinsing lab glassware e Supplying autoclaves and ultrapure water systems e Preparing and diluting buffers reagents and media J4 Ultrapure water which exceeds ASTM Type I standards with a resistivity of 18 2 MOQ cm and TOC 1 5 ppb with optional UV lamp High purity water ASTM Type II water with resistivity of 15 10 MQ cm is ideal for daily needs of 100 to 500 L Two systems in one e Unique systems with pretreatment plus polisher to produce both Type 1 and Type 2 water e Type 2 water is stored in the integrated 100 L high purity water reservoir e Water system sits on top of the reservoir saving critical bench space Ready to use e Feed water pressure switch all filters and cartridges sterile filter all in one package Two ways to draw water e Dispense ultrapure water directly from the system via the dispenser with sterile filter The water quality is measured immediately prior to the dispensing point e Type 2 water is accessible from the reservoir which is an ideal supply for lab equipment such as autoclaves Performance for your application feeds e High performance re
81. me membrane Electrodeionization EDI unites two proven technologies for producing ultrapure water Electrodialysis and ion exchange In contrast to conventional ion exchange in which resins must be either chemically regenerated or the cartridge discarded EDI utilizes an electric current for continual resin regeneration How EDI works Several layers of ion selective membranes are situated between an anode and a cathode Layered ion exchange resin beds and concentrate chambers are alternately positioned between them On applying an electric voltage water H 0 is split into H and OH in the cell The H and Na cations can migrate through the cation permeable membranes anions through the anion permeable membranes The ions migrate in the direction of the applied voltage i e anions to the positive pole anode cations to the negative pole cathode The water ions that migrate through an ion exchange chamber displace salt ions retained by the ion exchange resins and so continually regenerate the resins The salt ions migrate through the appropriate ion selective membranes into the concentrate chambers and are flushed out by water As all concentration chambers are flushed excess H and OH ions can again combine to form H30 Feed Water Requirements Source Potable tap water softened or hardness stabilized Conductivity uS cm lt 1500 Colloid index lt 3 pH range 4 11 Temperature C 2 35 Pressure
82. minal and membrane absolute filters Depth filters are most commonly used as a pretreatment and are manufactured by winding fibers around hollow and slotted tubes As water passes through the wound fiber matrix toward the center tube particles are retained on the fibers Traditionally this type of filter removes most of the impurities above the rated pore size of the filter Most often these filters are rated to remove larger particles gt 1 um to protect the technologies that follow Membrane filters are often termed absolute meaning that they are designed to remove all particles above the rated pore size of the filter These filters use a membrane in flat sheet or hollow fiber form and are most often used at the end of a system to remove bacteria or other particles that are not removed by the preceding technologies Traditionally membrane filters in laboratory water systems have a rated pore size below 0 45 um most often 0 2 um Benefits e Efficient operation e Maintenance is change out only Limitations e Clogging e Will not remove organics nucleases pyrogens dissolved gases or dissolved inorganics Systems that utilize this technology e Thermo Scientific Barnstead Genpure MicroPure E Pure LabTower EDI Smart2Pure Pacific TII LabTower TII water purification systems Ultrafiltration UF In water purification ultrafiltration is used to remove pyrogens bacterial endotoxins and nucleases which is critical f
83. mo Scientific Barnstead Smart2Pure water purification system continued Economical Design UV Oxidation 185 254 nm Sterile Optional UV oxidation for reducing Ultrapure water is dispensed the content of microorganisms and through an autoclavable 0 2um filter their metabolites The RO membrane with pretreatment cartridge is separate from the DI cartridge ensuring you only replace each cartridge as needed ny Product Specifications Storage Reservoirs Dimensions Volume Material H x D in mm 30 L 23 0 15 Polyethylene ultrapure water 998 x 380 resistant opaque to light 35 9 x15 ict 912 x 380 Storage Reservoir Options for 30L 60L Smart2Pure 12 System Only Tank Choose a tank to meet your capacity needs 06 5040 06 5070 Required Accessories Sterile overflow for reservoir 06 5001 06 5001 CO absorber sterile filter 0 2 um 06 5002 06 5002 Optional Accessories UV lamp assembly for the tank 230V Flexible Storage Ships complete with assembly and UV lamp Store high purity water safely and conveniently in either a 30 or 60 L reservoir only for Smart2Pure 12 06 5006 06 5006 Wall mounting bracket 06 5015 06 5016 Replacement Consumables Replacement UV lamp reservoir 230V 09 5002 09 5002 50 Product Specifications Smart2Pure 3 6 12 L hr Operating pressure Flow r ow rate min max up to 1 L min Smart2Pure System 3 and 6 L hr All systems include an RO pr
84. mponents you need to easily maintain your new water purification system innovations that deliver accuracy With innovative water monitoring technology Thermo Scientific water purification systems eliminate expense and lost time which may occur with contaminated lab water Advanced feed water monitoring Alerts the user to fluctuations in the feed water quality Poor feed water will reduce cartridge life TOC measurements with UV intensity monitoring Continuously monitoring and recording TOC measurements in real time this technology ensures ultrapure water that meets or exceeds even the most stringent requirements for sensitive applications A photo sensor continually checks the intensity of the UV lamp A drop in measured UV radiation can result in an incorrect TOC measurement EDI systems feature tank recirculation to maintain high quality pure water even during long periods of inactivity Automatic recirculation of the water in the tank across a special polisher actively protects against bacteria growth even during long periods of inactivity flexibility system design Mounting flexibility Installation options include under the cabinet on the wall on the bench or free standing units with wheels for added mobility Full system control at the Thermo Scientific xCAD remote dispenser Eliminate the hassle of going back to the primary system to adjust parameters Upgradeable units Growing the lab or
85. n System water purification system re Purified water flows into the still Distilled water feeds the MicroPure Tap water Still water flows into the reservoir Applications in the Lab General lab use rinsing of glass and plastic ware media prep HPLC Water Type s Needed Type 1 and Type 2 distilled Solution Barnstead Mega Pure Still with Automatic Collection System and a Barnstead MicroPure UV The Bauer Lab needed Type 1 water for their HPLC and analytical experiments estimated to be less than 15 L a day and distilled water for general reagent preparation and glassware rinsing thus our Barnstead MicroPure UV and a Barnstead Mega Pure Still with Automatic Collection System were recommended A dual cartridge deionizer was also suggested as pretreatment to the still as the lab s tap water was especially hard Pretreatment Barnstead Smart2Pure UV UF water purification system Tap water Applications in the Lab Protein purification and PCR Water Type s Needed Type 1 Solution Barnstead Smart2Pure UV UF Biochemical techniques such as protein purification and PCR are important for the Simpson Lab but they have serious space constraints Our Barnstead Smart2Pure UV UF is the all in one solution for tap to Type 1 water It converts tap water to ultrapure water and has a small foot print The UV UF option will provide the lab with nuclease free water perfect for their sen
86. not only to membrane performance and lifetime but also directly impact the quality of your product water Take advantage of our Thermo Scientific H 0 Select Analysis Kit our free comprehensive testing program which will analyze your feed water to ensure optimum RO performance More More Concentrated Concentrated Pure Water Solution Pure Water Solution e 25 v own OO lt Ww A Pressure Semi permeable Semi permeable Membrane Membrane Osmosis Reverse Osmosis The natural osmosic flow of water through a semi permeable membrane from less concentrated solutions to more concentrated solutions Reverse osmosis is achieved when external pressure is applied to reverse this natural flow as shown on the right Our technical service experts are a great resource for any feed water questions you might have Here is an explanation of key characteristics impacting RO performance Temperature Volumes listed for the reverse osmosis product water are based on a feed water temperature of 15 C 59 F For every 1 C below 15 C 59 F the quantity of product water is reduced by 3 Additionally if the feed water temperature goes beyond 25 C 77 F the RO membrane may be damaged We recommend a hot and cold water mixing valve to regulate the temperature to 15 C 59 F Alkalinity and calcium Carbonates bi carbonates hydroxides and calcium impurities in your feed water contribute to RO membrane scaling Both the Th
87. oPure MicroPure UV MicroPure UF MicroPure UV UF MicroPure system Line fed units 50132366 50132373 sus 32368 50132370 All systems include an ultrapure polisher cartridge Sterile 0 2 um filter pressure regulator UV lamp Integrated 6 L feed and or ultrafilter where applicable eT 50132367 50132374 50132369 50132372 Required Accessories pe Le x CD pa qe U s C2 pa et Sp lt Sp qe Fp Stainless steel DI cartridge DI 1500 Required only when feed water is pretreated using reverse osmosis to 02 1500 02 1500 02 1500 02 1500 meet feed water requirements and prolong cartridge life Optional Accessories Wall mounting bracket 09 2212 09 2212 09 2212 09 2212 Qualification Documentation IQ0Q Line fed units IOQDOCE50133913 I0QDOCE50133913 IOQDOCE50133913 10QDOCE50133913 Qualification Documentation 1000 Integrated 6L feed reservoir I0OQDOCE50133914 IOQD0CE50133914 IOQDOCE50133914 I0QDOCE50133914 Disinfection cartridge 09 1102 09 1102 09 1102 09 1102 Replacement Consumables Ultrapure polisher cartridge 09 1006 Sterile filter 0 2 um 09 1003 Ultrafilter 50133981 Europe Asia Pacific 09 2202 09 2202 09 2202 09 2202 Cleaning solution North America CMX25 CMX25 CMX25 CMX25 CE www thermoscientific com purewater 41 Thermo Scientific Barnstead E Pure water purification system The Barnstead E Pure economically produces Type 1 water wi
88. om human activity They may include proteins alcohols chloramines and residues of pesticides herbicides and detergents They foul ion exchange resins interfere with organic analyses including HPLC gas chromatography and fluoroscopy They will also hinder electrophoresis tissue and cell culture Speaking the Language of Pure Water Contaminants to Avoid in Your PURE Water gasses Application and Interest Areas General Lab Purpose Autoclave Humidification Glassware washing rinsing Media preparation Analytical lon chromatography IC a ae Atomic absorption AA mm High performance liquid chromatography HPLC Inductively coupled plasma spectroscopy ICP Mass spectroscopy MS Gas chromatography GC Total organic carbon TOC Life Sciences Genomics ex PCR mutagenesis Proteomics ex crystallography electrophoresis Immunology ex monoclonal antibody production blots Pharmacology Cell and tissue culture Drug discovery anne CAL ly Dissolved Gases Water naturally contains dissolved gasses such as carbon dioxide nitrogen and oxygen Carbon dioxide dissolves in water to form weakly acidic carbonic acid H C03 which can alter the pH of the water Additionally oxygen the most common non ionized gas may Cause corrosion of metal surfaces Microorganisms Bacteria fungi and algae are found in all natural water sources Chlorination elimina
89. or tissue culture cell culture and media preparation Ultrafilters use size exclusion to remove particles and macromolecules By design ultrafilters operate similar to reverse osmosis membranes particles are captured on the surface of the membranes and are flushed from the membrane via a reject stream Ultrafilters are used at the end of systems ensuring the near total removal of macromolecular impurities like pyrogens nucleases and particulates Mi f peene i A Final Filter Ultrafilter Benefits e Effectively removes molecules pyrogens nucleases microorganisms particulates above their rated size e Long life e Helps to remove pyrogens and nucleases Limitations e Will not remove dissolved inorganics dissolved gases and organics Systems that utilize this technology e Barnstead GenPure MicroPure and Smart2Pure water purification systems speaking the Language of Pure Water Reverse Osmosis Reverse osmosis is the most economical method of removing up to 99 of feed water contaminants Pressure To understand reverse osmosis you must first understand osmosis During natural osmosis water flows from a less concentrated solution through a semipermeable membrane to a more concentrated solution until concentration and pressure on both sides of the membrane are equal In water purification systems external pressure is applied to the more concentrated feed water side of the membrane to reverse t
90. ou ll appreciate the flexibility of this dispenser e One of a kind design provides access to all system controls at your fingertips e Specify bench top or wall mount xCAD dispenser for the installation option of your choice The small footprint of the bench top xCAD allows for more bench space while the wall mount version completely frees up horizontal workspace e Adjustable controller makes handling more practical and provides a clear view of critical settings e In addition to flexible xCAD installation options GenPure systems can also be installed under the bench or wall mounted with included mounting brackets XCAD Dimensions Dimensions W x D x H in mm Benchtop xCAD 10 2 x 21 x 28 5 260 x 530 x 725 Wall mount xCAD 10 2 x 21 x 25 8 260 x 530 x 655 Feed Water Requirements Potable tap water pretreated by reverse osmosis sours ion exchange or distillation Feed water conductivity pS cm lt 2 TOC ppb max 50 Bacteria count CFU ml lt 100 i Turbidity NTU lt 1 0 SS Complete water purification Temperature C 9 35 system control via the Pressure psi bar 1 4 87 0 1 6 XCAD remote dispenser Please see user manual for complete list of feed water requirements Product Specifications Operating pressure Dimensions Flow rate Electrical requirements Power consumption Feed water connector W x D x H in mm min max 29 87 psi ve 14 6 x 13 x 24 up to 2 L min 2 6 bar 90 240V 50 60Hz
91. pe Asia Pacific 09 2202 09 2202 09 2202 09 2202 09 2202 Cleaning solution North America CMX25 CMX25 CMX25 CMX25 CMX25 CE Storage Reservoir Options for Pacific RO 30 L 60 L 100 L with level display 06 5033 06 5063 06 5083 Reservoir with level display and pressure pump 06 5034 06 5064 06 5084 Required Accessories Sterile overflow for reservoir 06 5001 06 5001 06 5001 Sterile fiter 02pm filter 0 2 Sterile fiter 02pm 06 5003 06 5003 06 5003 Vent filter Choose the vent filter for your application needs Sterile filter 0 2 um CO absorber 06 5002 06 5002 06 5002 Optional Accessories UV lamp assembly for the reservoir with lamp 230V only 06 5006 06 5006 06 5006 Wall mounting bracket 06 5015 06 5016 na Replacement Consumables Replacement UV lamp Reservoir 09 5002 09 5002 09 5002 SWALSAS OF SWA SAS UONPIINUNd 1818 aNd pretreatment Not all feed water sources are equal Pretreatment is sometimes necessary to maximize the effectiveness of water purification systems Poor water quality can also shorten the life of water system consumables Mixed Multi Water Softener e Ideal system to treat hard feed water e Not only softens the water but also protects the RO membrane from blockage e Removes calcium magnesium iron and manganese and a great variety of suspended matter and organic material e Combination of multiple stages from porous polymeric adso
92. planning for changing needs Many of our systems can be upgraded to accommodate greater capacity Dual water quality Need more than one type of water Many of the systems produce two types of water from just one system www thermoscientific com purewater convenience with customized system selection Based on the results of a FREE Thermo Scientific H2O Select Analysis we will recommend the best water system for your application based on your feed water quality laboratory applications daily volume requirements and budget We do all the thinking for you How It Works 1 Contact your local sales representative for a free H2O Select Analysis Kit 2 Fill the sample bottle with your anticipated feed water 3 Answer the short questionnaire pertaining to your water requirements applications and budget 4 Place the completed application and water sample bottle in the return box Add postage and mail to the Thermo Scientific Barnstead Water Lab return label included in box All in One Box Ordering Have confidence in knowing that there are no surprises with added post sale costs Everything you need ships under one part number Easy Self Maintenance The Aquastop quick connections make changing your cartridges quick and simple Sand silt clay and other suspended particles cause water to be turbid These suspended particles can interfere with instrument operation plug valves and other narrow f
93. pment on or in the filter matrix Fouling When gelatinous coatings colloidal masses or dense bacterial growth form a compacted crust on membrane or filter surfaces which blocks further flow Grains per Gallon Concentration of dissolved ions in water generally as calcium carbonate 7 000 grains is equal to a pound One grain per gallon is equivalent to 17 1 ppm of Dissolved Solids Hardness Concentration of calcium and magnesium salts in water and is sometimes also taken to include iron and manganese High hardness can cause boiler or pipe scale and failure of reverse osmosis membranes lon Exchange Also called deionization A process in which harmless ions attached to the resin beads are exchanged for undesirable ions in solution Typically hydrogen ions are exchanged for any cations and hydroxyl ions for any anions The hydrogen and hydroxyl ions combine to form pure water Macroreticular Resin An ion exchange resin with a reticular porous matrix that makes it effective for removing colloids and bacteria as well as dissolved anions It is especially useful for preventing colloidal and organic fouling of mixed bed resins and premature clogging of final filters Megohm cm 0 A measure of ionic purity in water Resistivity the reciprocal of conductivity is a measure of specific resistance to electrical flow The fewer dissolved ions in water the higher its resistivity One megohm cm is equivalent to one mil
94. r all included in one part number Measurement of conductivity resistivity e Conductivity cells are carefully calibrated prior to each measurement via built in reference resistance with cell constants at 0 01 cm e Temperature measurements are made by a platinum chip sensor with 0 1 C accuracy Quick connect cartridge replacement e Aquastop quick connect capability enables cartridge replacement within seconds even mid operation Exact dosing e Electronic dosing for fully automatic volume control of 0 01 65 L with lt 0 5 accuracy GLP compliant documentation e Real time clock and code protected operating system prevents unauthorized changes to system settings e RS 232 interface with adjustable send interval for safe data transfer of all measured data faults date and time to a PC computer or log printer e Digital microprocessor control automatically monitors and stores faults from the last four weeks e USP compliant conductivity measurement with temperature compensation can be switched on or off extreme flexibility Quick Look Comparison GenPure xCAD GenPure xCAD GenPure xCAD GenPure xCAD GenPure xCAD GenPure xCAD system UV system UF system UV UF system UV TOC system UV UF TOC system Biosciences cell and tissue culture media PCR DNA monoclonal antibodies Chemical analysis trace analysis HPLC IC ICP MS TOC measurements Inorganic and organic trace analysis HPLC ICP MS IC
95. rbers to ion exchangers e Necessary for feed water with a silt density index SDI that is greater than 3 or the total ionized solids TIS is greater than 250 ppm Single Pretreatment Cartridge e Easy to use pretreatment cartridge protects the RO membrane in a system against particles e Ships with 10 inch filter housing and a 1 um filter e Ideal when feed water Silt Density Index SDI is 2 3 Double Pretreatment System e Ships with two 10 inch filter housings a combi cartridge which contains a 5 um filter and activated carbon and a hardness stabilizer cartridge e Removes chlorine organics and hard ions Triple Pretreatment System e Ships with three 10 inch filter housings a combi cartridge which contains a 5 um filter and activated carbon and a hardness stabilizer cartridge and a 1 um filter e An effective triple pretreatment system removes chlorine organics hard ions and particles larger than 1 pm www thermoscientific com purewater Mixed Multi Water Softener Double Pretreatment System Not sure what you need Request a FREE Thermo Scientific H 0 Select Analysis kit and let us analyze your feed water Your report will include a recommendation of any pretreatment system needed for your water purification system Thermo RO Water Deionized or Distilled Water Tap Water Tap Water Hard Tap Water 88 Barnsteac lentifi selector guide Use pretreatment when your
96. rd which plugs directly into the E Pure e Complete with 1 4 inch NPT T to install in your feed line Molecular Biology and Microbiology e Cell culture e Buffer preparation e Electrophoresis Low water level pump protector e f feeding your E Pure from a storage reservoir it is recommended that a low water pump protector be added to the E Pure system This will ensure that the pump is protected in the event the reservoir does not have a sufficient quantity of water to satisfy the requirements of the system e Adaptable to most storage reservoirs providing a 1 2 inch NPT connection is available Includes 6 ft 1 8 m cord which plugs directly into the E Pure Quick Look Comparison Resistivity at 25 C MQ cm 18 2 TOC ppb lt 10 Bacteria CFU mL g Flow rate L min 2 42 Feed Water Requirements Depending on the cartridge pack chosen potable tap water or Sonica water treated by reverse osmosis ion exchange or distillation Temperature C F 4 49 40 120 Pressure psig max 100 Please see user manual for complete list of feed water requirements Product Specifications Overall dimensions W x H x D Feed water connector Inlet water temperature 29 x 28 x 7 5 in 73 7 x 71 1 x 19 1 mm 1 4 in NPTF 35 X 28 X 7 5 in 88 9 x 71 1 x 19 1 mm 1 4 in NPTF E Pure 3 holder 40 120 F 4 49 C E Pure 4 holder 40 120 F 4 49 C Ships with wall bracket and cartridge o rings mov 5 min 4632
97. resins used in B Pure cartridges e Constructed of 100 virgin polypropylene cartridge e Designed for non pressure applications these cartridges include 3 8 inch barb hose connections on each end D8822 D8950 and D8951 cartridges include tapered straight nipple for 3 8 inch ID tubing e Color change indicator identifies when resin is exhausted in specific cartridges e Simple cartridge holder is easily wall mounted mg F qp oe Fp lt oe qp op Product Specifications Cartridge size Lene ter 1 2 Size 10 2 x 3 25 in 25 9 x 8 25 cm 2 3 Size 13 3 x 3 25 in 33 8 x 8 25 cm Full Size 18 7 x 3 25 in 47 5 x 8 25 cm Hose nipple cartridge holder For easy wall mounting D38900 Required Accessories e Pretreatment Miis at ci ae uaa indicato mbe 1 2 size mixed bed Ultrapure ion exchange 430 grains Mo e Deionization 1 2 size mixed bed Ultrapure mixed bed 280 grains D6822 e Organic and chlorine removal with oxygen removal with strong anion exchange 4 4g 7 aii Two bed ion exchange Feeding laboratory equipment 2 3 size high capacity E 1100 grains D8950 2 3 size mixed bed and Mixed bed ion exchange 470 grains organic removal with activated carbon 2000 gal Full size cation removal Cation exchange 3000 grains D8905 Full size high capacity Two bed ion exchange 1650 grains D8901 Full size macroreticular Macroreticular cation Full size organic removal Activated carbon 5000 gal
98. ressure gauge allows for monitoring inlet and outlet water pressure e Monitors pressure drop across any of the 10 inch 25 43 cm filter cartridges used in the 1 2 Size B Pure Filter Holder e Pressure drop of greater than 10 psi indicates need for filter change e Particulate and bacteria removal Economy Filter Holder 102 SE DIeIt RE 140 axible filtration system System Options Product Specifications Overall dimensions Inlet Feed water Max feed Max flow WxHxD connection temperature water pressure rate 7X15x7in To 17 8 x 38 1 x 17 8 cm 1 2 in NPTF 4 49 C 40 120 F 5 25 x 12 x 5 25 in E o 13 3 x 30 5 x 13 3 cm 3 4 in NPTF 4 49 C 40 120 F 1 2 Size B Pure holder Wall mount included 100 psig SIENS SES ENTTE Economy filter holder 100 psig Required Accessory 1 2 size B Pure Economy Filter Holder Holder FL583X4 18024 Pore Size Length in cm Diameter in cm 1 um Pre filter 10 25 4 2 5 6 5 5 um Pre filter 10 25 4 2 5 6 5 Filters Choose the filter s 10 um Pre filter 10 25 4 2 5 6 5 FL583X2 18011 according to 15 um Pre filter 10 25 4 2 5 6 5 FL583X3 18018 your needs 10 25 4 2 5 6 5 25 4 2 5 6 5 FL583X1 D2729 0 2 um Final Filter FL583X6 z 0 45 um Final Filter 10 25 4 Optional Accessories FL583X5 Dual pressure gauge kit D2780 Single pressure gauge D0780 z h E _ F oa F x F
99. rewater 53 en Select the b System TYPE 2 Therm lentific Barn s pure water purification system Ee selector guide z Take into account any new techniques you will introduce in the coming years or new volume demands you may have Optimal amount of water to use daily to sustain reasonable cartridge life Technology UV Oxidation Protects against microorganism Automatic operation Total operation of the system is automatic Multiple choices of dispense Flexible options for dispensing Upgradable If capacity needs increase the system can be upgraded 54 Multiple capacities available 3 40 L hr Optional Standard Standard Flexible dispensing 20 40 L hr Optional Standard Standard Standard Classic tin lined still with space saving design All glass design 1 4 13 L hr 7 6 19 L hr Optional for reservoir Optional Standard www thermoscientific com purewater Tin lined 1 9 38 L hr Optional for reservoir Optional 99 Thermo Scientific Barnstead Pacific TII water purification system The Barnstead Pacific TII water purification system converts tap water into high purity water The ultimate system for the automatic and economical production of Type 2 water the Pacific TII system supports daily requirements from 20 to 200 liters e Rinsing lab glassware e Supplying autoclaves and ultrapure water systems e Preparing and diluting buffers reagents and med
100. rganic Carbon TOC A measure of the level of organic impurities in water which determines the operating life of activated carbon beds Total Solids Total solids in water include both dissolved and suspended solids Turbidity A suspension of fine particles that obscures light rays but requires many days for sedimentation because of small particle size Two Bed Separate beds or layers of cation and anion exchange resins Results in lower purity than mixed bed deionization but provides higher capacity in terms of throughput Ultrafiltration Molecular sieves membranes with pores small enough to remove large molecules Rated in terms of nominal molecular weight cutoff A 10 000 Dalton molecular weight UF membrane for example will remove bacterial pyrogens which are typically in the range of 20 000 Daltons Ultrapure Water Water with a specific resistance higher than 1 megohm cm In the laboratory it usually refers to ASTM D1193 Type 1 reagent grade water Anything in laboratory water that is not H 0 is an impurity Although chemically pure water is not attainable ultrapure water systems are now capable of reducing impurities down to the limits of detection UV Oxidation Ultraviolet radiation is employed in water purification for the photochemical oxidation of organic impurities resulting in HPLC grade water with organic impurity levels below 5 ppb www thermoscientific com purewater 20
101. rval allows for customized timing of data transmission of measured values and faults to a PC or data printer e Cell constant of 0 16 cm ensures precise conductivity measurements Pacific RO pretreatment e Two 10 inch 25 4 cm cartridge filter housings with a 5 um prefilter activated carbon to prevent entry of particles gt 5 um and high concentrations of free chlorine Also includes hardness stabilizer cartridge which binds calcium and prevents its precipitation Worry free pure water storage e Reservoir are constructed of pigment free polyethylene e Conical bottom allows for easy cleaning disinfecting and complete emptying 82 M A for your RO water needs Te Quick Look Comparison Pacific RO Pacific RO Pacific RO Pacific RO Pacific RO 3 L hr 7 L hr 12 L hr 20 L hr 40 L hr systems systems systems systems systems Feed Water Requirements Source Potable tap water that has been softened or hardness stabilized Silt density index SDI lt 5 With higher values a pretreatment model no 09 4000 must be installed upstream of the system Conductivity pS cm lt 1500 Prefiltration 5 um activated carbon Free chlorine mg L lt 01 pH range 4 11 Temperature C 2 35 complete list of feed water specifications can be found in the operational manual ATION gt 83 Thermo Scientific Barnstead Pacific RO water purification system continued Storage Reservoir Volume Material Dimens
102. rvoir Floor Stand Storage Reservoir Wall Bracket Storage reservoirs e Available in 10 to 200 gallon reservoir options e Crafted from copper and hand wiped with pure tin to ensure the purity of the distilled water e All reservoirs include a removable cover water level sight glass and a tin coated draw off faucet with serrated hose nipple e Connections provide for optional accessories including pumps and fully automated controls e Requires a floor stand or wall bracket 10 and 25 gallon reservoirs only for proper installation Required Accessories Floor stand and wall bracket Choose either a floor stand or wall bracket for proper installation of reservoir Floor stands e 10 25 and 50 gallon reservoir stands are fabricated from heavy gauge sheet metal and have adjustable feet e 100 and 200 gallon reservoir stands are fabricated of thick steel angle iron Wall brackets e 10 gallon reservoir brackets are fabricated from heavy gauge aluminum e 25 gallon reservoir brackets are fabricated of thick steel angle iron Ventgard air filter and water seal e Protects the stored water against airborne particulates organics and CO e Water seal works as a one way valve to allow distilled water into reservoir e Prevents air from entering the reservoir via the condenser atmospheric vent UV light assembly e Maintains sterility in the reservoir e UV lamp is enclosed by a tubular transparent inert sheath e W
103. s Great option for customers with little no chlorine in their tap water typcially Europe and Asia Double Pretreament System 5 um filter with activated carbon cartridge hardness stabilizer cartridge Ships with two 10 inch filter housings Designed for customers with chlorine in their tap water typcially North America and UK Triple Pretreatment System 5 um filter with activated carbon cartridge hardness stabilizer cartridge 1um filter Ships with two 10 inch filter housings Mix Multi Mini Water softener 110V The softener will remove hardness and protect the RO membrane Additionally you will need to add a 5 um filter with activated carbon and a 1 um filter Ships with two 10 inch filter housings 230V Mix Multi Mini Water softener 110V The softener will remove hardness to protect the RO membrane Additionally you will need to replace the hardness stabilizer cartridge that ships with the unit with a 5 um filter with activated carbon 230V Dretrec stainless steel cartridge gt 10 inch 1 um filter with housing gt Mixed multi softener gt 5 um filter with activated carbon gt Mixed multi softener gt 5 um filter with activated carbon gt 10 inch 1 um filter with housing gt 5 um filter with carbon gt 10 inch 1 um filter with housing gt 5 um filter with hardness stabilizer gt 5 um filter with carbon and a hardness stabilizer cartridge gt 5 um filter with carbon and a hardness stabili
104. s and general laboratory use e A built in pretreatment unit consisting of a hardness stabilizer for protection of the reverse osmosis module from hardness formers e An activated carbon 5um combi cartridge protects the system against free chlorine and particles ensures the long service life of downstream purification stages Compact and mobile design e Two system options with permeate flows of 20 or 40 L h e Stand alone design with integrated 100 L tank takes up ZERO bench space e Casters allow for easy relocation e Systems can be upgraded later to accommodate growing water capacity demands Integrated 100 L reservoir e 100 L RO water storage in a high purity polyethylene PE opaque reservoir e Adjustable reservoir volume can be programmed for times of low demand e Dispense from the reservoir to supply autoclaves glassware washers incubators etc e Rinsing lab glassware e Supplying autoclaves water baths Easy to operate clear display incubators and glassware washers al 2 e Resistivity conductivity clearly displayed on large back lit control panel that tilts al for optimum viewing lt e Status of current operating mode clearly indicating production stand by or cleaning modes e Preparing and diluting buffers and reagents e General biotechnology aa e Reservoir fill level shown as e System parameters are code protected to prevent accidental changes to set points GLP compliant documentation e
105. s for cleaning D7034 D7034 Thermo Scientific Barnstead TII System Consumables TH 12 L h D14031 TII 24 L h D14041 Replacement Cons umables ae ia ee filter 03750 0502137 1 pm pre filter D502113 MPS cartridge D502114 Extruded carbon cartridge D502115 0 2 um final filter D3750 Reverse osmosis membrane FL1265X1 Ultraviolet lamp system LMX13 Ultraviolet lamp reservoir LMX31 Ventgard reservoir cap CV703X4A f D7401 D7411 D8611 D502124 D502126 D502124 D502125 D502127 D502125 D3750 D3750 D3750 LMX13 n a LMX13 n a FL1192X1 FL1192X1 CMX25 CMX25 CMX25 Thermo Scientific Barnstead Easypure RoDi System Consumables D13321 Replacement Consumables Cartridge kit Includes pre filter ultrapure mixed bed cartridge and D502133 Easypure high purity low TOC cartridge 0 2 um final filter D3750 Ultraviolet lamp LMX13 Ventgard reservoir cap CV703X4A Reverse osmosis membrane FL1332X2 Set of three empty cartridges for cleaning D7034 Thermo Scientific Barnstead RO System Consumables RO 6 L h D12671 RO 12 L h D12651 i RO 24 L h D12661 Replacement Consumables Reverse 6 and 12 L h FL1265X1 osmosis membrane 24 L h FL1265X1 Requires 2 RO membranes please order 2 1 um pre filter D502113 MPS cartridge D502114 Extruded carbon cartridge D502115 Ventgard reservoir cap CV703X4A www thermoscientific com purewater 105 support and maintenance Contact the Pure Water Experts Have a question
106. se osmosis water purification systems Water purified using reverse osmosis is useful in supplying water to lab equipment such as water baths dishwashers and autoclaves Innovation Thermo Scientific Barnstead LabTower RO system allows the tank level to be set manually convenience Dispense easily from the tank flexibility Endless mounting choices on the bench on the wall or free standing www thermoscientific com purewater reverse osmosis 76 Reverse osmosis is economical Reverse osmosis is the most economical method to remove up to 99 of impurities in feed water The RO membrane is semi permeable with a thin microporous surface that rejects virtually all dissolved materials including inorganic solids organics particles and microorganisms Reverse osmosis water is versatile RO water can be used to prepare microbiological buffers and chemical reagents Additionally it is a great option for use in general laboratory equipment such as water baths humidifiers and autoclaves Reverse osmosis is effective As the feed water passes through the RO membrane impurities deposit on the surface of the RO membrane and are flushed away to the drain The result is purified product water free of up to 99 of its impurities The specific rejection rates of all the impurities are shown in each of the product specifications Feed water factors Certain characteristics of your feed water directly relate
107. sitive applications www thermoscientific com purewater 21 ultrapure water purification systems What sets Thermo Scientific Barnstead water purification systems apart Our Barnstead water purification portfolio includes a complete line of Type 1 systems to meet all your ultrapure water needs Why so many options For you to have a tailored system specifically for your needs No need to pay for technologies that you won t use UV and feed water monitoring for maximum efficiency EDI systems with reservoir recirculation maintains purity even between use Quick change cartridge design simplifies self maintenance All required parts and accessories ship under one part number Full system control at the Thermo Scientific Barnstead GenPure xCAD remote dispenser www thermoscientific com purewater ie Feed water 11 Jatt ultrapure water purification system A 4 24 Applications Technology selector guide Select the water system that best fits your requirements Ultra low organic levels lt 5 ppb HPLC TOC GC MS ICP ICP MS Cell culture monoclonal antibody production electrophoresis Nuclease and pyrogen free applications such as PCR 2 D electrophoresis cell culture blotting UV monitoring Feed water monitoring Total Organic Carbon TOC monitor Volumetric Dispensing GenPure xCAD remote dispenser Under the bench mounting
108. tes harmful bacteria but tap water still contains live microorganisms which interfere with sterile applications such as cell and tissue culture Pyrogens and Viruses Pyrogens or bacterial endotoxins are lipopolysaccaride molecules incorporated in the cell membrane of gram negative bacteria Viruses are considered to be non living nucleic acids Both can adversely affect laboratory experiments often hindering cell and tissue growth in culture www thermoscientific com purewater Nucleases RNase and DNase are naturally occurring enzymes that are instrumental in regulating bodily functions As important as these enzymes are to the life process they can be devastating to nucleic acid experiments If these contaminants are present in the pure water used the ability to amplify DNA molecules will be severely limited Likewise experiments utilizing RNA can be ruined To make pure and ultrapure water the impurities discussed on the previous page must be efficiently and effectively removed Barnstead water purification systems employ multiple technologies some synergistically to remove impurities and give you consistently PURE water Water purification is a step by step process often requiring a combination of technologies each of which varies in the ability to remove specific contaminants The table below illustrates which impurities are removed by each technology Flaine Ultrafiltrati Ultraviolet Combinati Distillat
109. th low operating costs Large cartridges provide longer cartridge life and an impressive system flow rate Product Features Resistivities up to 18 2 MQ cm and TOC levels below 10 ppb Virgin polypropylene water pathways prevent recontamination e Recirculation pump continuously recirculates water throughout the entire system to maintain water purity and reduce the quantity of waste water required for rinse up e Wall mountable and completely assembled for easy installation Quarter turn quick release canisters allow for easy cartridge replacement 0 2 um absolute final filter removes bacteria and particulates protecting the integrity of your results Digital resistivity meter is automatically temperature compensated to 25 C preventing fluctuating readings due to temperature changes High capacity cartridges provide low operating costs Product Accessories Remote dispenser e Recirculates water through to tip of dispenser and includes a 0 2 um final filter e Delivers water up to 8 ft 2 4 m from the system e Ships with a mounting bracket for increased flexibility in choosing a mounting location Low pressure pump protector e f you are feeding your E Pure system from a pressurized feed line it is to your advantage to ensure that the pump is fully protected with the use of the low pressure pump protector e Interrupts power if pressurized feed water line pressure falls below 5 psig 0 35 kg cm e Includes 6 ft 1 8 m co
110. tical hands on instructions Validation We offer validation services according to cCGMP GLP regulations certifying that your system is performing to pre determined technical specifications Our validation services provide you with e Factory trained experts experienced in cCGMP GLP environments and Good Document Practice e 0 00 factory developed validation protocols Please ask your local sales representative for additional information about service offerings in your area www thermoscientific com purewater 107 Go Green Smart Green designs mean a great water system for you and a smaller impact on the environment Our engineers created water systems with the environment in mind Reduce Our cartridges use high quality resin to extend the useful life of the cartridge Extended life reduces the need to replace your cartridges which in turn reduces the waste stream and improves your laboratory s sustainability You ll use your cartridges longer reducing the need to reorder ship handle and dispose of your cartridges Our units are designed to minimize the amount of water that is used during the analysis To provide the customer with pure water and low power consumption our units go into a low energy mode after dispensing without sacrificing water quality for your applications Reuse Our cartridges were engineered with the environment in mind The plastic cartridge casings and endcaps are constructed us
111. tories that require up to 15 L day of ultrapure water such as HPLC or other instrumental analyses sample preparation glassware rinsing or molecular biology work in which endotoxins and or nucleases would interfere Molecular Biology and Microbiology e Cell and tissue culture e PCR DNA sequencing e Electrophoresis Analytical Chemistry e HPLC e GC GC MS ICP MS AA e TOC Measurements IC _ compact system Smart features e Backlit display tilts for easy viewing e Variable speed dispensing e Optional integrated 6 L feed water reservoir so you can place the system without direct access to a water line Monitor feed water quality e Good feed water quality leads to consistently ultrapure water and a longer cartridge service life to maximize cartridge life Smart design e Recirculation pump prevents bacterial growth during standstill and allows for constant monitoring of all system functions allowing for the immediate display of fault messages if a problem is detected e Systems ship fully equipped with pressure reducer ultrapure cartridge and 0 2 um sterile filter Superior filters e Ultrafilter is flushed automatically to assure the highest retention of endotoxins and nucleases which produces a long two year lifetime e Validated 0 2 um final filter with folded membrane can be sterilized up to 5 times for small ultrapure water demands 38 Quick Look Comparison Instrumental analytical High sens
112. treatment options to minimize scaling automatic controls that allow stills to work automatically with pretreated feed water and a storage reservoir Step By Step technologies used in distillation systems ab Feed water enters the still through the Cooling Water Feed Water Inlet As the water passes through the Inlet it becomes warmed as it makes its way to the boiler It in turn cools the vapor entering the condenser U lt qp ja qP s U o Sp lt ep go OO Water flows from the condenser into the constant level device then into the boiler amp The water in the boiler is heated Impurities with a boiling point higher than water 100 C 212 F remain in the boiler while water and impurities with a boiling point equal to or lower than water are converted to water vapor The pure vapor moves up the boiler through a pyrogens reducing baffle and into the condenser a In the condenser the pure vapor is transported through the condenser where it contacts tubes or coils containing cooling water The pure vapor contacts these tubes and coils and is condensed to produce pure water The distilled water exits the condenser and is stored in a reservoir through the Distilled Water Outlet Atmospheric vent allows for volatile contaminants to be vented increasing the purity of the distilled water www thermoscientific com purewater 73 rever
113. up to four L min e Complete with draw off valve e Choose from models with digital purity meter or Pura Lite Go No Go resistivity indicator Half size holder e Produces up to 2 L min e Easily attaches to full size B Pure systems e Small size allows for flexibility in mounting location e Pretreatment e Deionization e Organic and chlorine removal e Feeding laboratory equipment Quick Look Comparison Resistivity reading Flow rate Up to 4 L min 1 10 MQ cm depending on cartridges used SE DIeIt RE 140 NI 2AaDIe TC oretreatment or deionization needs 4 Harvey DI Cartridge System mg qe n O WM lt op qe O e Turn key system ships complete with a remote dispenser Pura Lite 50 KQ cm indicator and a high capacity two bed ion exchange cartridge to remove calcium magnesium and other ions from water e The Harvey DI system accepts a broad range of other cartridges to remove impurities and produces pure water at a flow rate of 4 L min Product Specifications Overall dimensions Inlet Feed water Max feed Max flow WxHxD connection temperature water pressure rate 7X 24x7 in C 7 Single holder 17 8 x 61 x 17 8 cm 1 2 in NPTF 4 49 C 40 120 F 100 psig 4 L min 15x27x7in oc o i Double holder 38 1 x 68 65 x 17 8 cm 1 2 in NPTF 4 49 C 40 120 F 100 psig 4 L min Half size holder a a 1 2 in NPTF 4 49 C 40 120 F 100 psig 2 L min 17 8 x 38 1 x 17 8 cm
114. vation Joints and seams are ultrasonically welded to prevent contamination from chemical adhesives convenience Quick release designs provide easy cartridge change outs and simplify maintenance bypassing the costs of service calls flexibility Versatile configurations meet an array of specific applications tific com purewater you re purifying Are the water systems h under pressure Thermo Scientific Barnstead cartridge amp filter selector guide Choose the feature you need Technology Feature D Digital Purity Indicator Pura Lite Go No Go Purity Indicators Analogue Resistivity Indicator Color Change Cartridge Remote Dispenser Wall Mounted Added Features Quick Release Canisters Maximum Flow Rate L min 94 Benefits Digital purity indicator features real time readout of resistivity values useful with more sensitive applications Quick glance monitoring to notify user when it s time to install a new cartridge Useful if cartridge system feeds a piece of lab equipment such as an autoclave where real time resistivity is not required Color change indicates when the cartridge is beyond it s useful life and must be replaced Useful for general lab applications Hand dispense water from the cartridge system Ideal for rinsing glassware or filling a waterbath saves laboratory bench space Ideal configuration for autoclaves and dishwashers where no benc
115. verse osmosis module is paired with an EDI module and polisher cartridge e Two systems to choose from with capacities of 15 and 30 L per hour Quick Look Comparison LabTower EDI 15 LabTower EDI 30 system system Type 1 Water Resistivity at 25 C MQ cm 18 2 18 2 Conductivity uS cm 0 055 0 055 TOC ppb 1 5 Bacterial content in CFU mL g lt 1 Particles 0 22 um mL lt Flow rate at dispenser L min 1 5 Type 2 Water Pure water production at 15 C 5 30 Resistivity at 25 C 15 10 15 10 Conductivity 0 067 0 1 0 067 0 1 2i A Compact stylish mobile e Free standing unit takes up no bench space e Easily relocated with bottom mounted rollers Safe operation e Microprocessor control for automatic operation e Continuous monitoring of all critical parameters e Recirculation pump protects purified water from bacterial growth during standstill GLP compliant documentation e Real time clock and code protected operating system prevents unauthorized changes to system settings e RS 232 interface with adjustable send interval for safe data transfer of all measured data faults date and time to a PC computer or log printer e Digital microprocessor control automatically monitors and stores faults from the last four weeks e USP complying conductivity measurement with temperature compensation that can be switched on or off 100 L Integrated polyethylene reservoir safely stores Type 2 water e Automatic water recircu
116. wing you to only store water that you can use Clear information on system display e The large four line display is code protected to prevent accidental changes in system settings e lluminated and easily readable the display provides information on resistivity or conductivity operating mode status such as production stand by or sanitization and volume of the reservoir in GLP compliant documentation e Developed to meet or exceed GLP requirements e Recorded and traceable data can be obtained by print out via the RS 232 interface and accessory printer e Highly qualified and precise measurement of the conductivity is ensured by the cell constant of 0 01 cm to an accuracy of 0 1 C with integrated 100 L tank Quick Look Comparison LabTower TIl LabTower TII UV system system Pure water production at 15 C L hr 20 or 40 20 or 40 Resistivity at 25 C MO cm 10 1 Conductivity uS cm 0 1 1 Bacteria content CFU mL with sterile filter lt Particle content 0 2 pm per mL with sterile filter lt 5 um prefilter and activated carbon in the combi filter cartridge protects the RO membrane from chlorine and particles Hardness stabilizing cartridge protects the reverse osmosis stage from hard water Pretreated water is pressure forced through the permeable reverse osmosis module removing 97 99 of all inorganic ions 99 of dissolved organic substances as well as microorganisms and particles T
117. y water cartridge 10 inch hardness stabilizing cartridge pressure regulator integrated 100 L reservoir and UV lamp where applicable 90132193 90132141 90132191 50132196 Required Accessories 5um filter with activated carbon LabTower TII Pretreatment and a 10 filter housing Both cartridges are required for complete pretreatment 90134022 90134022 1pm filter with a 10 filter housings 09 4003 09 4003 06 5003 06 5003 90132714 90132714 Sterile vent filter for reservoir Sterile overflow for reservoir Optional Accessories UV lamp assembly for reservoir 230V only Includes holder and UV lamp 06 5006 06 5006 Water watcher Alerts the user to leaks Available as 230V only Hehe 10 0123 Printer 110V AY1137X1 AY1137X1 Utilizes RS 232 interface for safe documentation of all measured values and faults with date and time in compliance with GLP Guidelines 230V 09 2207 09 2207 Qualification documents 10 0Q I0QDOCE501 34156 I0QDOCE501 34156 Replacement Consumables High purity water cartridge 02 2850 LAB 02 2850 LAB Reverse Osmosis membrane 22 0046 22 0087 LabTower TII 20 and 40 systems require two membranes as indicated must order 2 must order 2 09 4002 09 4002 09 1003 09 1003 09 2202 09 2202 CMX25 CMX25 System UV lamp Sterile 0 2 um filter Europe Asia Pacific Cleaning solution North America Activated carbon cartridge with 5 um prefilter 06 5201 06 5201 Hardness stabilizing cartridge 06 5452 06
118. zer cartridge gt 1um filter gt Mixed multi softener gt 5 um filter with activated carbon gt 1um filter gt Mixed multi softener gt 5 um filter with activated carbon gt 1um filter gt Mixed multi softener gt 5 um filter with activated carbon gt Mixed multi softener gt 5 um filter with activated carbon gt men 02 1500 see pages 56 63 09 4003 90129892 06 5201 06 1250 06 5201 09 4003 90134022 09 4003 09 4001 09 4000 09 4000 09 4003 90129892 90134022 09 4003 06 1250 90134022 09 4003 90129892 06 5201 06 1250 06 5201 l m LN mi S 4 in 4 1 LE J a 3 7 t g i z A 4 Le L i L sea b __ E L d 1 ia TER TYPE 1 TAP TYPE 1 TYPE 2 RO m _ a i ia E D GenPure D MicroPure SmartaPure LabTower EDI Pacific TII LabTower TII Pacific RO LabTower RO J J Ships with dum filter with hardness stabilizer www thermoscientific com purewater 89 pretreatment selector guide continued Replacement Consumables Pretreatment Model Number s Component Model Numbers Pretreatment Description Component Description s Single Pretreatment Cartridge 10 in 25 4 cm 5 um filter and hardness stabilizer 06 5204 Single Pretreatment System 10 in 25 4 cm 1 um filter 06 5101 eam 10 in 25 4 cm Activated carbon cartridge with 5 um filter 06 5201
Download Pdf Manuals
Related Search
Related Contents
Série Ponto - Configurações da Remota PROFIBUS Avaya 3600 Telephone User Manual MESA MBF2620ECSD Instructions / Assembly : Free Download, Borrow, and Streaming : Internet Archive user manuals - Agromehanika Soler & Palau BOX-600 INOX N cooker hood Tech air Travel Trolley 15.4" Solar WiFi Kit Data Logger Quick Guide Copyright © All rights reserved.