USER`S MANUAL - RF Logics Inc
Contents
1. 12 4 SETUP MENU F4 i VERSION B oe ce F W key lt 4 gt or lt 6 gt SRAM TEST SRAM TEST key lt 4 gt or lt 6 gt OUTPUT TEST OUTPUT TEST key lt 4 gt or lt 6 gt LCD TEST LCD TEST ee eae KEYPAD TEST KEYPAD TEST rr lt 6 gt READER TEST READER TEST key lt 4 gt or lt 6 gt INPUT TEST INPUT TEST key lt 4 gt or lt 6 gt gt COMM TEST ae TEST 12 4 1 VERSION CHECK VERSION The version of the controller s firmware is displayed on the LCD Press lt 4 gt or lt 6 gt key to look for other menus 505R V5 0 of setup menu F4 IDTECK 45 EET WOK Proximity T amp A Access Controller 12 4 2 SRAM TEST SRAM TEST To test the SRAM memory press lt ENT gt key i f the SRAM has problems LCD will show the memory Memory fail 00 block number with Memory fail message In this case RAM testing you have to contact technical support Press any key to return to the setup menu RAM test pass f the SRAM is working properly the LCD will show RAM test pass message Press any key to return to the setup Press any key Onl 12 4 3 OUTPUT TEST Relay 1 test This test is applicable to Oe ee Lay Activated two times ei and LED Relay 2 test This test is applicable to Activated two times Relay2 and LED TTL Output 1 test This test is applicable to Activated two times TTL1 OV 5V
2. RS422 RX ep Converter GG Txt A TX 1 Termination Resistors Last 503R Figure Termination resistors for 4 wire RS422 communication system 7 2 3 GROUNDING SYSTEM FOR COMMUNICATION CABLE We recommend to using proper grounding system on the communication cable The best method for grounding system is to put the shield wire of the communication cable to the 1st class earth grounding however it is not so easy to bring the earth ground to the communication cable and also the installation cost is raised There will be three grounding point where you can find during installation 1 Earth Ground 2 Chassis Ground 3 Power Ground The most important point for grounding system is not to connect both ends of shield wires to the grounding system in this case there will be a current flow through the shield wire when the voltage level of both ends of shield wire is not equal and this current flow will create noise and interfere to communications For the good grounding we recommend to connecting ONLY one end of shield wire of communication cable to grounding system If you find earth ground nearby then connect one end of shield wire to earth ground If you do not have earth ground nearby then find chassis ground and connect one end of shield wire to chassis ground If you do not find both earth ground and chassis ground then connect one end of shield wire to power ground GND of Star 505R Note that if the chassis ground is not prope
3. TTL Output 2 test This test is applicable to Activated two times TTL2 OV 5V Enter any key Buzzer Output test This test is applicable to Activated two times Buzzer OUTPUT TEST To test the outputs press lt ENT gt key i The output test will proceed on and off twice for each output The first two tests are for the output relays Relay 1 Relay 2 You can hear the mechanical sound of relays and following two tests are for TTL output OUTPUT 5 testing The last test is for the built in buzzer and you can hear two beep sounds Press any key to return to the setup menu Press any key IDTECK 46 EET Won Proximity T amp A Access Controller 12 4 4 LCD TEST LCD TEST Press lt ENT gt key to continue the test LCD will display all characters on the screen Last Update When the test is done the LCD will show Last Update Press any key Press any key Press any key to return to Setup menu 12 4 5 KEYPAD TEST KEYPAD TEST Press lt ENT gt key to start the keypad test LCD will display 0123456789ABCDEF on the bottom line of LCD Press each key from the keypad The depressed key will disappear from the LCD Note that F1 key is A F2 key is B F3 key is C F4 key is D ESC key is E and ENT key is F on the screen 0123456 789ABCDEF After the test is done it returns to setup menu 12 4 6 READER
4. You may repeat ID DELETE many times Press lt ESC gt key to exit the menu ID number of SR505 is 10 digits decimal number 12 3 3 ID LIST ID LIST A LCD display MEMORY EMPTY lt ENT gt im gt YES DISPLAY ID NUMBER P W T S DOOR FLAG ID LIST ID xxx xxx PW1234 TSOO RDS MEMORY EMPTY ID LIST TOP ID LIST BOTTOM SEARCHING ID USE SEARCHING KEY f you want to see the list of registered User IDs press the lt ENT gt key in this menu i Put in 8 digit user ID 4 digit password the applied T S and the reader code is displayed on the LCD You can scroll up and down the list by pressing lt 4 gt and lt 6 gt keys Press lt ESC gt key to return to the setup menu i MEMORY EMPTY message will be displayed if there is no registered User ID i ID LIST TOP message will be displayed first when the first registered User ID is displayed on the LCD i ID LIST BOTTOM message will be displayed first when the last registered User ID is displayed on the LCD ID number of SR505 is 10 digits decimal number IDTECX 43 Star 505R Proximity T amp A Access Controller 12 3 4 REGISTERED ID COUNT i This menu displays the total number of registered User REG ID COUNT ID It automatically counts when you register or delete 1234 User IDs The LCD shows 1234 User IDs registered in the 12 3 5 ID COU
5. 2 is operated the yellow LED is turned on 16 key pad You can operate Star 505R manually by using the key pad Function key The Star 505R has four Function keys F1 F2 F3 F4 Card reading status LED IDTECK 8 Star 505R Proximity T amp A Access Controller When a card is read the card reading status LED turns on green Backup Battery DIP Switch Star 505R has a switch for the backup battery connection which remains open circuit to prevent any current consumption of the backup battery 6 2 2 WIRE COLOR TABLE OF THE Star 505R I O PORT NAME SIGNAL NAME WIRE COLOR OUTPUT Alarm NC NC oa wire with white stripe EXTRA READER RS232 TX Black wire with white stripe RS232 RX Red wire with white stripe a TOG RSK nD RS422 sn FRA Brown wire IDTECK star R Proximity T amp A Access Controller 7 Installation Checkpoint amp Tips Installing the Star 505R is an easy task It can be installed with common hand tools and readily available communications wires This section provides information about wiring wire runs and other information to make the installation quick and easy 7 1 CHECK POINTS BEFORE INSTALLATION 7 1 1 SELECTION OF CABLE system installation cabling will be configured as follow RS427 Rae232 Converter HOST e SS gt gt DC12V DC12V Power Supply Power Supply A yi EF Render Lock Alarm RF Reader Lock Alarm Sensor Input Sensor Ip Figure System In
6. ENT to complete setting NOT USE The value matched with the Function key will not be changed until another function key is pressed USE User can see OK under normal status and the value matched with Function key will be shown on certain WAIT TIME time when function key is pressed WAIT TIME Time duration between the display of value 00 matched with function to display OK default 12 1 15 DATA BYTE TYPE SETTING SR505 FUNCTION Bli IIE Ms is Card data management can be selected in this menu The ABYTE default value is 4 BYTE and generally this value may not need to be changed If customer needs to add more units where SR505 V1 0 is installed the user needs to change DATA BYTE TYPE the value to 2BYTE Otherwise please do not change gt OBYTE this value 12 2 SETUP MENU F2 34 Star 505R Proximity T amp A Access Controller INDEX 01 10 gt TIME SCHEDULE lt WEEKLY HOL SUN MON SAT NO 01 05 key lt 4 gt or lt 6 gt INDEX 01 10 NO 01 32 HOLIDAY DEFINE lt A 01 EXIT key lt 4 gt or lt 6 gt 02 DOOR CONTACT 03 INPUT 1 04 INPUT 2 05 TAMPER S W 06 R1 ID OK Y 07 R1 ID ERROR 08 R1 T S ERROR ec a 09 R1 APB ERROR A 10 R2 ID OK 11 R2 ID ERROR 12 R2 T S ERROR 13 R2 APB ERROR SEARCHING KEY key lt 4 gt or lt 6 gt 14 DURESS MODE lt 4 gt or lt 6 gt 15 OUTPUT 1 S 16 IN OUT T S Y HOLIDA
7. SEE Won Proximity T amp A Access Controller Compatible Readers 905R iP 505R Standard 26bit Wiegand Format Proximity Readers Standard 26bit Wiegand 8bit Burst Format Proximity and Keypad Readers SR505 Standard 34bitWiegand Format Proximity Readers Standard 34bitWiegand 8bit Burst Format Proximity and Keypad Readers Recommended Readers 505R RF TINY RF10 RF20 RF30 RFK101 FGR006 FGROO6EX iP 505R IP10 iP20 iP30 IPK101 SR505 SR10 SR20 SR30 SRK101 FGROO6SR FGROO6SRB 9 Communications 9 1 RS232 COMMUNICATION PORT CONNECTION A 9 pin connector Serial communication connector female is required to connect the 505R to a host computer via RS232 communication Please follow the instructions 1 Connect RS232 TX Black wire with White stripe wire of 505R to the pin 2 RX of the 9 pin connector 2 Connect RS232 RX Red wire with White stripe port of 505R to the pin 3 TX of the 9 pin connector 3 Connect GND Black wire of 505R to the pin 5 of the 9 pin connector 4 Plug in the 9 pin connector to COM1 or COM2 Port of the host PC 5 Install and run 505R Application Software RS 232 COMMUNICATON 18 SEE Won Proximity T amp A Access Controller 9 2 RS 422 COMMUNICATION PORT CONNECTION 9 2 1 RS 422 CONNECTION STAND ALONE RS422 RS232 converter CNP200 is required to use RS422 communication between the 505R and a host computer Please follow the instructions 1 Connect RS422 TX Yell
8. and the cursor will blink then enter the beginning time of the period in the form of hour 2 digit minute 2 digit and the ending time in the same form Then the lower line will indicate the defined period For more schedules repeat the process To end time scheduling press lt ESC gt key Possible values for time scheduling 1 Time schedule number 01 10 Needed when IDs are registered 2 A day of the week MON TUE WED THU FRI SAT SUN HOL 3 Index 1 5 referred to the five periods of time of a day 12 2 2 REGISTERING AND CHANGING HOLIDAY TIME SCHEDULE 36 Star 505R Proximity T amp A Access Controller HOLIDAY T S lt ENT gt DISPLAY CURRENT T S SELECT T S NUMBER AND INDEX USE 2 8 4 6 KEY lt ENT gt ENTER T S 4 DIGIT MM DD NO or lt ESC gt HOLIDAY T S i You can register up to 32 specified holidays per year for each schedule setting There can be 10 other registration sets created meaning holidays can be set for up to 10 years Press lt ENT gt to register the days ne ee _ With the lt 2 gt key and lt 8 gt key select the Date 01 Registration Set Number 1 10 and with the lt 4 gt key and lt 6 gt key select the index for the days 1 32 Press lt ENT gt key and the cursor will blink Enter the date in form of the Month 1 12 The LCD will indicate the defined date Now a day has been registered For fur
9. Please refer to the APPENDIX for the default setting values 25 EEE Won Proximity T amp A Access Controller 12 Setting Changes INITIAL DISPLAY MODEL NAME CURRENT TIME mwm 0 OPERATE GENERAL YES MODE SETUP MODE SETUP F1 MODE SETUP F2 MODE SETUP F3 MODE SETUP F4 MODE 1 READER 1 MODE 1 TIME SCHEDULE 1 ID REGISTRATION 1 VERSION 2 READER 2 MODE 2 HOLIDAY SETTING 2 ID DELETE 2 SRAM TEST 3 TIME SETTTING 3 IN OUT DEFINE 3 ID LIST 3 OUTPUT TEST 4 APB SETUP 4 HOLIDAY INDEX 4 REG ID COUNT 4 LCD TEST 5 COMM ADDRESS 5 MODE INDEX 5 ID COUNT 5 KEYPAD TEST 6 BAUD RATE 6 LCD DISPLAY 6 READER TEST 7 EVENT CLEAR 7 OUTPUT TIME SET 7 INPUT TEST 8 COMM TEST 8 MASTER ID CHANGE 9 SYSTEM INITIALIZE 10 CARD ID CLEAR 11 TIME SCHE CLEAR 12 RF PIN INPUT 13 EVENT MEMORY 14 DURESS MODE SET 15 FUNCTION KEY 16 DATA BYTE TYPE s To setup or to change the 505R settings you have to enter the SETUP MENU first To do so press the lt 0 gt key eight times for Master ID Default setting 00000000 and lt ENT gt key from the Keypad Now you can get into SETUP MENU There are 4 main SETUP MENUS and you first get into SETUP MENU F1 You can move to other SETUP MENUS by pressing lt F1 gt key for SETUP MENU F1 lt F2 gt key for SETUP MENU F2 lt F3 gt key for SETUP MENU F3 and lt F4 gt key for SETUP MENU F4 There are several SUB MENUS in
10. Press lt ENT gt key CLEA then press the lt 1 gt key to clear all User IDs or lt 0 gt key to cancel the operation CAUTION Before clearing all User IDs make sure that CARD ID CLEAR the registered User ID is no longer used otherwise you 1 Yes O No may lose all registered User IDs 12 1 10 TIME SCHEDULE CLEAR TIME SCHE CLEAR gt When you want to delete all Time Schedules 01 15 you can clear them from the memory Press lt ENT gt key and press the lt 1 gt key to clear all T S or lt 0 gt key to cancel the operation TIME SCHE CLEAR CAUTION Before you clear all T S make sure that the stored T S is no longer used otherwise you 1 Yes O No mav lose all stored T S in the memory 12 1 11 KEYPAD INPUT SETTING RE PIN INPUT This function is to DISABLE ENABLE the keypad inputs 1D from th sProximity and Keypad Readers The default DISABLE setting is fo DISABLE the keypad inputs If you install the Keypad Reader 8bit burst format and set this mode to ENABLE you can access the door by pressing an 8digits User ID with the keypad Star 505R Proximity T amp A Access Controller RF PIN INPUT gt ENABLE 12 1 12 EVENT MEMORY SETTING EVENT MEMORY You can select whether you will use event memory or not E When you select USE and in case of an event memory US 505R generates an error message and keeps all events stored in the memory When you select NOT USE 505R will not generate an
11. cable the propagation velocity of cable is 0 66 x speed of light This value is specified by the cable manufacturer if we assume the reflections will damp out in three round trip up and down the cable length the transmitted signal will stabilize 18 6us after the leading edge of a bit Since the data bit is captured in the middle of the bit which is approximately 52us after the leading edge of a bit The reflection stabilizing time 18 6us is much before the center of the bit therefore the termination resistors are not required However if you install the cable to maximum length the impedance of cable and network is mismatched and the transmitted signal is overlapped by the reflected signal In this case it is recommended to add termination resistors to the end of the receiver lines A 120Q resistor can be used for termination resistor in parallel between the receiver lines A and B for 2 IDTECK 11 Star 505R Proximity T amp A Access Controller wires RS485 system or RX and RX for 4 wires RS422 system A termination resistor of less than 90Q should not be used and no more than 2 terminations should be used in one networking system 7 2 2 HOW TO CONNECT TERMINATION RESISTORS R5455 RS485 RS232 gm a lt SS Converter e p A B og i ae B Termination Resistors a Last 504R Figure Termination resistors for 2 wire RS485 communication system 1204 Fy TX4 GG RA A RS48S RS232 RS422
12. error and new event overwrite into the EVENT MEMORY event buffers If you use 505R for standalone just for door gt NOT USE access select NOT USE 12 1 13 DURESS MODE SETTING yo Oa DURESS MODE SET lt ENT gt NOT USE default key lt 4 gt or lt 6 gt gt USE lt ENT gt v DURESS P W lt ENT gt ENTER NEW P W 2digit lt ENT gt _ lt BNT gt DURESS MODE SET You can select whether the DURESS mode is used for NOT USE READER1 Default setting is NOT USE If you want to eon Duress mode press the lt ENT gt key and select IDTECK g ey F key y The CD will display default Duress Password 00 Press lt ENT gt key again to enter a 2 digits Duress Password Press lt ENT gt key to finish the setting SEE Won Proximity T amp A Access Controller DURESS MODE SET gt USE DURESS P W 00 12 1 14 FUNCTION KEY SETTING SR505 FUNCTION FUNCTION KEY The User can decide what will be shown on display matched with Function key Default value for FUNCTION NOI is KEY is NOT USE and set USE in order to apply FUNCTION KEY F1 F2 F3 F4 for Time amp Attendance If FUNCTION KEY WAIT TIME is set system will be back to default status _ display OK Press ENT key to change the value from gt NOT USE left figures FUNCTION KEY i Select mode by pressing lt 4 gt lt 6 gt key After selecting gt USE mode press
13. in IN OUT DEFINE of F2 the fifth Time schedule code 01 10 value of 15 output T S If the time schedule code is set between 01 up to 10 and if the present time is included in the schedule If it is set to unintended value change it to 00 Programmable via PC software 4 f the trouble remains after checking the above contact a designated service center ia SCHEDULE ERROR message shows when RFID card is read Cause Error in RFID card registration time schedule setting or the system itself Solution 1 If it was a properly operating unit before there has been an electric shock that damaged the internal memory and data Please initialize the unit as instructed in the manual 2 Check if ID information has been put in incorrectly during its registration Register ID again checking the following points IDTECK 93 EET SUOR Proximity T amp A Access Controller In order to restrict access of the ID user for specific time zone as instructed in the manual register time schedule in advance and apply the time schedule code 1 10 in the registration of the user ID In order to allow the user to access at all times put in 00 3 Use software for time schedule setting in case it is connected to PC as the software manual 4 If the trouble remains after checking the above contact a designated service center i ACCESS DOOR ERR message shows when the RF ID card is read Cause Incorrect user setting or false
14. oF Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea TEL 82 2 2659 0055 FAX 82 2 2659 0086 www idteck com RMA REQUEST FORM send to RMA No amp Date RMA Customer Service Original Invoice No amp Date 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Sales Person In Charge Shipping Pot Arvesse Departure Da Model SerialNumber Serial Number Error Check Box by shipper RS 232 Com o Power o Card Reading o Engineer is Input Output o Keypad o RS 422 Com o Requested from RS 232 Com o Power o Card Reading o oo Input Output o Keypad a RS 422 Com o PS 232 Com o Power o Card Reading o a Input Output a Keypad a RS 422 Com a comment RS 232 Com o Power o Card Reading o a Input Output o Keypad o RS 422 Com a eso FP RS 232 Com o Power o Card Reading o z eaa o Keypad o RS 422 Com o Manufacture s Verification Product Defective Installation Error User s Misuse Connection Error Communication Error Others Packing Details Dimension L W H No of Units Net amp Gross Weight No of Boxes Requested by Received by Signature of Buyer Signature of IDTECK Star 505R Proximity T amp A Access Controller RMA REQUEST FORM SAMPLE fold IDTECK Co Ltd yesi ID CASH POINT 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea TEL
15. of internal circuit Solution 1 If it was a properly operating unit before there has been an electric shock that damaged the internal memory and data Please initialize the unit as instructed in the manual 2 Check if ID information has been put in incorrectly during its registration Register ID again and check the following points Since the controller has two reader ports define RD door for the user to be allowed to access Reader1 only 1 Reader 2 only 2 Reader 1 amp 2 both 3 If RD is set as 1 only when the card is read at Reader 1 the door opens but not at Reader2 If it is read at Reader 2 ACCESS DOOR ERROR message shows up If RD is set as 2 only when the card is read at reader 2 the door opens but not at reader If it is read at reader 1 ACCESS DOOR ERROR message shows up If RD is set as 3 reader 1 amp 2 both open each door 3 Use software for time schedule setting in case it is connected to a PC shown as in the software manual 4 If the trouble remains after checking the above contact a designated service center 54 Star 505R Proximity T amp A Access Controller The controller does not communicate with the Host PC Cause A defective cable is used errors in wiring an error in setting COMM ID of the controller or damage on the communication port either on PC side or on the controller side Solution 1 Please check the sett
16. off v Normal Operation Disconnect 3 wires pink cyan black To set up or to change the 505R settings you have to enter the SETUP MENU first To do so press the lt 0 gt key eight times for the Master ID Default setting 00000000 and the lt ENT gt key from the Keypad Then you can get into SETUP MENU There are four main SETUP MENUS and you first get into SETUP MENU F1 You can move to another SETUP MENU by pressing the lt F1 gt key for SETUP MENU F1 lt F2 gt key for SETUP MENU F2 lt F3 gt key for SETUP MENU F3 and lt F4 gt key for SETUP MENU F4 There are several SUBMENUS in IDTECK SEE SUOR Proximity T amp A Access Controller the main SETUP MENU and you can scroll up and down the SUBMENU by pressing lt 4 gt and lt 6 gt key in the main SETUP MENU If you dont press any key for 60 seconds or if you press the lt ESC gt key 505R will exit the SETUP MENU and return to normal operation You can also change the Master ID in the SETUP MENU F1 In the case of SR505 Press ten times the lt 0 gt key Default setting 0000000000 to enter the SETUP MENU 10 3 DATE AND TIME SETTING Select TIME SETTING in the SETUP MENU F1 and enter the Year Month Date Hour Minute Second Day Total 15 digits as shown below The LCD will display the new Date and Time after the time setting completed but the year and day will not be displayed 505R has a 24 hours system and da
17. to RX port of the converter 2 Connect RS422 TX Grey wire of the one 505R to RX port of the converter 3 Connect RS422 RX Blue wire of the one 505R to TX port of the converter 4 Connect RS422 RX Brown wire of the one 505R to TX port of the converter 9 Plug the RS232 9 pin connector of the converter into the COM1 or COM2 Port of the PC 6 Install and run the 505R Application Software Past A Past A RS 422 232 CONVERTER RSI32C Figure RS 422 Communication between 505Rs and Host Computer 20 Star 505R Proximity T amp A Access Controller 9 3 DIAL UP MODEM Please read the Software manual 9 4 TCP IP CONVERTER EXTERNAL VERSION Please read the Software manual 10 Basic Settings 10 1 INITIALIZATION OF 505R Connect the cyan pink and black wires they are seen from the rear view together and Power on the unit If you want hardware initializing press Enter key lt 1 gt After initializing Put the main power OFF and separate 3 wires Pink cyan and black GND Afterwards put main power ON again Power on N Initialize OK 0 NO 1 Yes If you turn on the system power after connected 3 wires pink cyan and black GND you can enter into system initialize mode NO Yes y Initialize Com Turn OFF Power y System initialization completion 10 2 HOW TO ENTER THE SET UP MENU Power
18. 505R 9 Identifying Supplied Parts Proximity T amp A Access Controller Please unpack and check the contents of the box Optional accessories if purchased may be included in the package O O o Q Main Unit Wall Mount O ring User s Manual Diode 1ea 1ea 5ea 1ea 2ea 6 Product Overview 6 1 Functions Stand Alone Operation The Star 505R is capable of having 2 readers 1 Door Control The unit receives card ID numbers from the proximity readers and determines whether or not to unlock the door When an input signal is entered for example from a Sensor activated or an Exit button pressed the controller generates and logs an appropriate response by input signals All events are stored into the memory buffers and sent to the host computer The access controller is a true stand alone device that in the event of malfunction will not affect other units when used in conjunction with one another Operation with Host Computer All event transactions can be managed via the host computer The data transmitted from the controller can be displayed and stored on the host PC Data Backup The controller retains all user information and event data for 30 days even in the case of power failure Xx CAUTION Battery switch must be set correctly before the unit running See the INSTALLATION section Keypad lf the Star 505R is not connected to a host PC the integrated keypad and LCD display module can also be used fo
19. 82 2 2659 0055 FAX 82 2 2659 0086 www idteck com RMA REQUEST FORM Send to RMA No amp Date We will send this No if needed RMA Customer Service Original Invoice No amp Date 00 00 0 000 2005 10 01 OF Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Requested from Seoul 157 030 Korea Mr XXXX YYYY ABC Company Sales Person in Charge Address Karina Kwak Country Supping Pori Departure Date 2005 10 15 SR 10 RS 232 Com o Power m Card Reading m Engineer Write problem must be Input Output a Keypad a RS 422 Com o Comment detailed Others g others RS232Com o Power o Card Reading o Input Output o Keypad o RS 422 Com o Engineer an Po RS 232Com a Power a Card Reading a 3 Engineer Input Output a Keypad o RS 422 Com a Comment ay Others o Po RS 232Com a Power a Card Reading a Engineer Input Output o Keypad o RS 422 Com o Comment foteso rT PR 232Com a Powerc Card Reading Engineer Input Output a Keypad a RS 422 Com o Comment Otherso PP Manufacturer s Verification Product Defective Installation Error User s Misuse Connection Error Communication Error Others Packing Details Dimension L W H 30 25 80 No of Units 20 Net amp Gross Weight 1509 No of Boxes 2 Requested by Received by XXXX YYYY Signature of Buyer Signature of IDTECK 99 Star 505R MEMO Proximity T amp A Access Controller 60 Star 505R MEMO Prox
20. F P W 4digit PIN 4 6digit only 505M Magnetic stripe Magnetic stripe P W 4 SEE Won Proximity T amp A Access Controller 4 Specification CPU 8bit Microprocessor Memory Program Memory 64KB ROM Data Memory 128KB RAM battery backup Power DC 12V 350mA max excluding lock current Card Holders User programmable by 500 units of card holders Event Buffers Reader Ports Reader Data Format Communication port Card Holders 500 10 000 users Default 5 000 users Event Buffers 2 500 7 250 events Default 5 000 events 1 External port 1 Internal port Wiegand format standard 26 bits Wiegand Format Standard 34 bits Wiegand Format Applied to SR505 8 bits burst Format for keypad reader RS232 RS422 up to 32 channels selectable 4800 9600 Default 19200 38400bps communication speed Inputs Outputs 4 Input ports DC12V 20mA 2 Relay Output ports DC12V 24V FORM C Relay 2A max 2 TTL Output ports DCSV 20mA self Diagnosis Yes Reset Power on reset and Watchdog timer reset Operation Status Operating Environment 3 LED Red Green Yellow indicators 0 C 65 C 0 90 Humidity Weight 4009 Dimensions 150mm 5 9 x120mm 4 72 x39 5mm 1 55 Keypad 16 keys LCD Display Module 2Lines x 16ch 2 62 x 0 55 65 6mm x 13 8mm viewing area STAR 505R Series STAR 505R Built in 125KHz PSK Reader STAR SR505 Built in 13 56MHz MIFARE Reader IP 505R Built in 125KHz ASK Reader Star
21. N If you select PIN it will be affected to Reader 1 and 2 READER 2 MODE setup is the same as above The SR505 doesn t have READER 2 MODE It is used RF PASSWORD mode only Reader 1 12 1 2 TIME SETTING i Press lt ENT gt key and enter 15 digit Date Time codes then lt ENT gt key to finish setting TIME SETTING YYYY Year MM Month DD Date hh Hours 24 hours system mm Minutes ss Seconds W Sun 1 Mon 2 Tue 3 Wed 4 Thu 5 Fri 6 Sat 7 YYYYMMDDhhmmssW eee ee a Example 200302101330152 SSS SS gt Feb 10 2003 13 30 15 Mon 29 EEE Won Proximity T amp A Access Controller 12 1 3 ANTI PASS BACK MODE SETTING It shows anti pass back operation is not in use APB SETUP Press lt ENT gt key NOT USE it only applies when the door has an Exit Reader i Press lt 4 gt or lt 6 gt key for searching the APB mode APB SETUP Press lt ENT gt key to select the mode gt USE NOT USE Anti pass back mode is not applied USE Anti pass back mode is separately applied APB SETUP f you select All Clear UR will clear all APB flags and all users are not allowed Exit first gt Al Clear COMM ID OR Se ER mmunication ID setting menu SETTING To change the ID press lt ENT gt key COMM ID The number on the LCD is the current communication ID Device No Press lt ENT gt key again to set a new SETTING communication ID COMM ID When the cursor is blinking enter a new ID t
22. NT ID COUNT lt ENT YES gt ENTER NO 4 5 digit ID COUNT VALID REGISTERED ID COUN lt ENTER NO YES y COMPLETE EVENT MEMORY EMPTY NO v DISPLAY EVENT MEMORY NOT EMPTY A DISPLAY INVALID COUNT lt DISPLAY ID TOTAL COUNT WRONG ANO ID COUNT i Press lt ENT gt key to change maximum ID Count Note This must be setup first before any other setup Please refer to section 7 4 ID COUNT SETTING Enter number from 500 to 10000 in multiple of 500 for the HUER VD COL maximum User ID count Example 500 1000 2000 10000 ___ Then press lt ENT gt key LCD will display Invalid Count error message when you enter the ID Count which is not multiple of 500 or the ID Invalid Count Count is not in between 500 and 10 000 EVENT MEMORY LCD will display EVENT MEMORY NOT EMPTY error message when you want to change ID Count and there are NOT EMPTY some events still existing in the Event Buffer LCD will display ID TOTAL COUNT Wrong error message PO UCN when you enter the less ID Count number than the number of User ID registered in the memory Note This must be set up first before other setups Wrong Star 505R Proximity T amp A Access Controller
23. OFF Power appears on the LCD and turn it off and on again Try entering the Setup mode Note that all the value will be set to default including the IDs after initializing 3 If the trouble remains after the procedure above contact a designated service center No problem with accessing by card but cannot access with the PIN input Cause An error in Setup or possible component defect 1 Check whether a beep sound is generated when you press a key Solution When a beep sound is generated the problem may be an error in setup Proceed like followings Enter the Master ID 00000000 default to enter the Setup mode Note that the Master ID for SR505 is 10 times lt 0 gt 0000000000 Press lt F1 gt key READER 1 MODE will appear on the LCD then use the key lt 6 gt to choose RF_PIN_INPUT and select Enable as wanted 2 When there is no beep sound or already enabled Key in functions contact a designated service center i Can set the controller to operate in RF only mode for one card and in RF P W mode for another Cause N A Solution 1 Do not mix the working mode for one Reader 2 One reader can be set to operate in RF only mode and another one in RF P W mode The Setup mode suddenly goes back to the Normal operating mode Cause Time out error In the Setup mode it is programmed to do so when there is no key in or reading card Solution within 60 seconds 92 EE Won
24. Proximity T amp A Access Controller The reader seems to read cards but the controller does not respond or does not respond properly such as displaying wrong card numbers in the reader test mode Cause Reader defect wiring error between the reader and the controller or the electric noises around Solution 1 Be sure that the reader reads the card ID when you present a card 2 Be sure that the reader format is correct 26bit Wiegand or 34bit Wiegand for SR505 3 Check the wiring between the reader and 505R Check the wires of Wiegand data lines DO and D1 which is connected correctly Connect the controller ground to the ground wire of the reader and it is recommended to connect them to an earth ground 4 Using an oscilloscope check the shape of signals from the reader at the controller s side When noises are shown on the signals it is recommended to use shielded wires and the unused wires to the common ground You can also use repeaters 9 Check the maximum cable length which may be indicated on the reader manual 6 If the trouble remains after the procedure above contact a designated service center t Keeps making buzzer sound beep beep beep or beeeeeeeep Cause Error in Installation Door status or Internal circuits Solution 1 Check the door status It occurs in case that the door is opened over 20 sec after the proper door open time 2 Check the door contact sensor type it should be NO type 3 Check
25. RD PRESENT CARD ERROR DISPLAY KEY A y Invalid Card ID Invalid T S 1 Invalid T S 2 Invalid RD ID REGISTRA ID REGISTRA Scanning ID _ PW _TS__RD_ ID xxx xxx PW TS_RD_ IDTECK ENTER NEW ID 8 digit Card data Card ID Error No lt v INPUT PW TS RD PW TS RD Error NO v ID REGISTRATION END Press lt ENT gt key to register new User ID ID Number is registered in the controller by RF cards or through the keypad For RF cards press lt 1 gt key the keypad lt 2 gt key or you can quit the registration by pressing lt ESC gt key The reader is waiting for an RF card which has to be registered The card number will appear with a beep as the card is read Enter 8 digit Card ID in the ID fleld and press lt ENT gt key Enter 4 digit Password in the PW ___ field and press lt ENT gt key Even if you dont use a Password it is necessary to enter 4 digit Password as default Example 0000 The LCD s lower line indicates that the four digit password time schedule index and reader code are needed Enter those values referring to the following information Then the registration of the card is finished EET SUOR Proximity T amp A Access Controller 1 PW Password the password used in RF password mode 2 TS Time schedule 00 Anytime accessible ID
26. Registered 01 10 Accessible according to each T S index 3 RD Reader code 1 for using reader 1 alone 2 for using reader 2 alone 3 for using both reader 1 and 2 ID number of SR505 is 10 digits decimal number 12 3 2 ID DELETE DELETE SELECT ND gt TDS ME lE 1 CARD 2 KEY lt ENT gt ENTER CARD NUMBER 8 Digit lt ENT gt i LCD Display ID DELETED C Yes sin LCD Display UNREGISTERED ID lt No ID DELETE Enter 8 digit User ID that you want to delete and press lt ENT gt ID Number is deleted in the controller by RF cards or ID through the keypad For RF cards press lt 1 gt key the DELETE keypad lt 2 gt key or quit the registration by pressing lt ESC gt key i This figure appears when you press the lt 1 gt key The reader is waiting for an RF card which is to be deleted The card number will appear with a beep as the card is read Scanning Enter 8 digit User ID that you want to delete and lt ENT gt Enter Card No ID number consists of 3 digits Facility code from 000 to 255 gt and 5 digits ID number from 00000 to 65535 so that the 8 digits ID number can not exceed 25565535 42 Star 505R Proximity T amp A Access Controller ID Deleted f the User ID you entered is found the User ID will be deleted and display ID Deleted If the user ID is not found the display will show ID Unregistered
27. Star 505R Proximity T amp A Access Controller USER S MANUAL Star 505R IDTECK SR505 PASS IP505R Proximity T amp A Access Controller Rev 5 0 gl i C1 C2 EDA ae be m a 4 ay is 4 j J 5 J 6 J j f j ie ae 5 i 7 A A 7 L XD 0 SEE Won Proximity T amp A Access Controller Table of Contents 1 Important Safety Instructions cc eesseesesesseeseesseeseesensessaeesensetsessaeeenees 3 2 GONGI A satan RA code BRUNI aan Rr E 3 OASIS 4 a OG CITE ATI 0 ARA EEA IRA TRENT RATAR SNU 9 9 Identifying Supplied Parts 02eeeesersnsrrnrns rss 6 0 PFOCUGE OV GI VIOW sannan a aa nan ni al a 6 7 Installation Checkpoint amp Tips 2 10 DIS LAN ACION at astan a a aa a a R a 14 9 COPING AUN OINS oiea aeaa e eee enna seers 18 10 ASIC SEMINO S orrip ak RA A a GR A la naga 21 IODE AON kastast ang 25 1A SEUNG CHANGES orire aenean Ea a EAEE ATEA 26 iP a 0 071 0 aaa ne en EEEE EE E E E 49 14 FCC Registration Information ccsssscsessseesseeseesseesesssecsenssensenseeseneees 56 15 Warranty and Service siss 57 16 RMA Request FOTM ni ast asninn paiaina 58 A TENDIT airone ne A i 62 IDTECK 2 Star 505R Proximity T amp A Access Controller 1 Important Safety Instructions When using Star 505R basic safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons In addition the following safety guides should
28. TEST READER i Press lt ENT gt key for the reader test TEST LCD will display Scanning for reading the cards Sl oe Present the card to one of the readers i When the reader successfully read the card LCD will Reader 1 display reader number and the 8 digit card number on 00312345 the LCD Press lt ESC gt key to return to the setup menu ID number of SR505 is a 10 digit Decimal number Reader Card 47 SEE Won Proximity T amp A Access Controller 12 4 7 INPUT TEST INPUT TEST i Press lt ENT gt key for the input test The 5 digits shows the input status and 1 indicates that the input port is open circuit and 0 indicates that the INPUT TEST input port is short to ground level iA 11 Press lt ESC gt key to return to the setup menu INPUT 12 4 8 COMMUNICATION TEST Before this communication test connect the RS232 RX COE and RS232 TX wires together Then press lt ENT gt key i This test is a loop test and 505R sends a character to TX data O RS232 TX and check whether the RS232 RX receive the COMM fail character or not If you have an error please contact our service facility COMM test pass After the test is done LCD will display COMM test Press any key pass Press any key to return to the setup menu Star 505R 13 Appendix Proximity T amp A Access Controller A THE RELATION BETWEEN INPUT AND OUTPUT DEFAULT 1 The re
29. UTION Before mounting the STAR 505R unit to the Wall Mount bracket operational test of the unit should be completed as the locking pins will lock the unit to the Wall Mount Removing the unit from the Wall Mount bracket after they have been installed together may cause damages to the bracket and render its effectiveness 8 4 3 Insert 5 O rings to the wall mount as indicated then route the cable of the main unit through the center hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with wall mount 8 5 WIRING 8 5 1 POWER Connect wire of DC 12V power to the Red wire Connect GND wire of DC 12V power to the Black wire 8 5 2 INPUT CONNECTIONS Exit Button Connection Connect one wire from an Exit Button to the Orange wire Connect the other wire from the Exit Button to the GND Door Contact Sensor Connection Connect one wire from a Door Contact Sensor to the Yellow wire with Red stripe Connect the other wire from the Door Contact Sensor to GND Auxiliary Input Connection Applied to Aux Input 1 Green wire Aux Input 2 Green wire with White stripe Connect one wire from an Auxiliary Inout Device to one of the Input 1 2 Connect the other wire from the Auxiliary Input Device to GND SENSORUNPUT DEVICE CONNECTION a TAR SUSE DOOR SENSOR l l GND Boni Yellow wire with Fed stri DC12Vi2 5A Min it Figure INPUT DEVICES CONNECTION 16 SEE W
30. Y INDEX lt 2 2 HOLIDAY DEFINE INDEX 01 10 key lt 4 gt or lt 6 gt MODE INDEX lt TIME SCHEDULE INDEX 01 10 key lt 4 gt or lt 6 gt y E STATUS LCD DISPLAY gt NUMBER key lt 4 gt or lt 6 gt gt lsec p gt OUTPUT TIME SET gt 100ms 12 2 1 REGISTERING AND CHANGING TIME SCHEDULE TIME SCHEDULE lt EN gt DISPLAY CURRENT 1 S IDTECK 35 li SELECT T S NUMBER AND INDEX USE 2846 KEY lt ENT gt EET Won Proximity T amp A Access Controller TIME You may program time schedules to grant and restrict access for each user There can be up to ten different Sin schedules minimum of one schedule must be defined If only one schedule is programmed the most common setting allows access for all users 24 hours day A time T S O1 HOL 1 schedule can be programmed for each day of the week 00 00 00 00 and holidays and five shifts can be defined for each day To set time schedules press lt ENT gt key from this menu If you want to set time schedules press lt ENT gt key when this figure is displayed i Press lt 2 gt key or lt 8 gt key to adjust the Time Schedule T S number 1 10 and the day of the week Mon Sun and HOL Define which shift of the day 1 5 using the lt 4 gt key and lt 6 gt key HOL refers to specific holidays you will register see 13 2 2 page 28 Press lt ENT gt key
31. also be followed 1 Fully read and understand all instructions and follow them completely 2 Follow all warnings and instructions marked on the product 3 Do not use liquid or aerosol cleaners Use a damp cloth for cleaning If necessary use mild soap 4 Do not use this product near water 5 Only operate this product using the type of power source indicated If you are not sure of the type of power supplied to your installation site consult your dealer of local power company 6 Never insert objects of any kind into the product or through the cabinet slots as they may touch voltage points and or short circuit parts possibly resulting in fire or electric shock Never spill liquid of any kind on the product 7 Never disassemble this product by yourself take the unit to a qualified service center whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c lf the product does not operate normally after following the operating instructions in this manual Adjust only those controls that are covered by the operating instructions in this manual Improper a
32. ay schedule and the time code for holidays is programmed to the holiday time zone of time schedule Example A Holiday schedule 01 linked to time schedule 01 Holiday schedule 02 linked to time schedule 02 B Holiday schedule 02 linked to time schedule 01 Holiday schedule 01 linked to time schedule 03 Forced Door Open Alarm When the door is opened by force the door contact sensor will be activated The forced door open alarm will be generated until the door is closed again For this application you have to install the door contact sensor and properly set the door contact time and outputs to the alarm devices Duress Alarm In case of duress enter the 2 digits Duress Password and press the lt ENT gt key before the normal access process The door can be opened as normal but the duress alarm is also generated at the same time The duress alarm output will be activated to the TTL output and an alarm event will be sent to the host PC 6 2 Product Explanation IDTECK 7 EET Won Proximity T amp A Access Controller 6 2 1 Front Panel Description Card Reading Status LED System Operation Status LED 16 key pad Figure Description of Star 505R Front Panel Switch OFF Switch ON Figure Description of Star 505R Back Panel LCD Module LCD module display 505R status System Operation Status LED When the power is applied to 505R the red LED is turned on When the Relay 1 is operated the green LED is turned on When the Relay
33. connected so that the backup battery can retain the memory during power failure Figure DIP SWITCH SETTING Figure DIP SWITCH LOCATION 8 3 SYSTEM INITIALIZATION Connect the cyan wire pink wire and black wire they are seen from the rear view together and power on the unit If you want hardware initialization press enter key lt 1 gt After initializing switch main power OFF separate the three wires pink cyan and black GND and switch the main power ON again IDTECX 14 roximity T amp A Access Controller Power on N se If you turn on the system power 4 after connected 3 wires pink cyan and black GND you can enter Initialize OK into system initialize mode 0 NO 1 Yes Yes Normal Operation es Initialize Com Turn OFF Power Power off ta Disconnect 3 wires pink cyan 1 black System initialization completion 8 4 INSTALLATION OF THE PRODUCT 8 4 1 Tear off page 56 and use the provided template to drill two 6 32 holes and one 1 2 hole on the proper location of the wall to mount the Wall Mount bracket as shown below Skip this step if the aana box is alreadv installed on the wall 6 32 hole 1 55 39 5mm 1 85 47mm Fl el Wi dl on 2 2 05 52mm 1 52 38 5mm 1 52 385mm 3 03 77mm 15 SEE Won Proximity T amp A Access Controller 8 4 2 Using 2 screws install wall mount to the wall Xx CA
34. d the access of the door during the Time Schedule code entered to TS__ To control the accessible Time Schedule for each cardholder you must setup the Time schedules first and enter the Time Schedule code here If you want to access the door anytime for the cardholder then enter default Time Schedule code 00 for the value 9 RD__ RD is the Reader Usage code for the cardholder If you put in 1 for RD Reader 1 is accessible and if you put 0 for RD the cardholder can not access through the Reader 1 Reader 2 505R generates an error message Access Door Error and displays it on the LCD To get access through all Readers you have to put in 3 as a value for RD 11 Operations 11 1 NORMAL OPERATION Power on When the power is applied to 505R the Red LED is turned on Registered card reading When a registered card or PIN is read the Door Relay 1 will open for 3 seconds Default with the Green LED on Exit Button To request an exit from the inside an Exit Button or an Exit Reader can be used The Door Relay 1 will open for 3 seconds with the Green LED on Alarms When an unregistered card is read the access is denied and the alarm Relay 2 will be activated for 3 seconds with the Yellow LED on 11 2 DEFAULT SETTING When you operate the 505R for the first time or want to initialize the 505R the controller will setup all value defaults factory settings You can change the settings for the desired application
35. djustment of other controls that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to restore normal operation d Ifthe product exhibits a distinct change in performance 2 General The Star 505R is a highly advanced intelligent single door controller with a dual 8bit microprocessor to meet the market requirement for a robust integrated solution for access control and time amp attendance It is designed for low cost as well as high security convenience and reliability This user friendly device allows you to register 500 10 000 ID numbers and can keep 2 500 7 250 events Number of ID amp IDTECX 3 EEE WOK Proximity T amp A Access Controller Events can be exchanged under the ratio of 2 to1 which means every 500 users can be converted to 250 events The Event buffer reports and archive information to Excel or Access databases and ultimately manage all access control and time amp attendance issues With a built in 4 inch RF reader and keypad for Personal Identification Numbers PIN the STAR505R offers up to two levels of ID verification You can verify by Proximity Card PIN or both and multiple verification levels can be custom programmed for each user or user group Four independent input ports can be utilized for a wide variety of controls including exit buttons door contacts PIR sensors and fire detection equipment Actions to be taken and time settings can b
36. e programmed with the front keypad or via the intuitive Windows based software program The Star 505R can be used both as a stand alone system and also be networked All control setting values such as ID numbers inputs outputs real time clock time schedules and event transaction reports can be uploaded and or downloaded to and from the host computer The compact and contemporary unit is easily installed and programming requires no significant knowledge of access control or time amp attendance The three LED indicator lights inform you of the systems operating status at real time and the digital display acts as a programming aid as well as a regulation time clock By bundling the ultimate in high security access control and comprehensive employee management tools into a compact user friendly unit the field proven Star 505R is the ideal solution for controlling entrances and ensuring complete employee accountability 3 Features Dual function for Access Control and Time amp Attendance 505R Dynamic control of memory up to 10 000 Card holders 7 250 Events Standalone Network communication via RS232 RS422 max 32ch TCP IP available with LAN converter Independent 4 inputs and 4 outputs including 2 FORM C relay output External reader port for Anti pass back operation Dual Tamper Switch Comparison Table Dual function for access control and Time amp Attendance Built in 125KHz RF Reader 4 back lighting on keypad RF Only R
37. e the equipment NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help 56 SEE Won Proximity T amp A Access Controller 15 Warranty and Service The following warranty and service information applies only to the United States of America and Republic of Korea For the information in o
38. imity T amp A Access Controller 61 EET Won Proximity T amp A Access Controller 17 Template p 6 32 hole 1 2 hole 62 EEE WOR Proximity T amp A Access Controller FE f 4 4 The specification contained in this manual are subject to change without notice at any time oF Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com MAR 2006 Copyright 2006 IDTECK Co Ltd
39. ings of the application S W and the controller Check if the controller s COMM ID is listed on the application S W Set the different COMM ID when two or more controllers are installed Check if the communication speed 9600bps default is the same as the setting on the S W Make sure that the PC s COM port is set correctly on the S W The parameters at the S W should be set as following Parity bit NONE Data bit 8bit Stop bit bit 2 Check the line connection for communication RS232 RS422 Single Drop RS422 232 505R 505R Converter 7 ne The RS232 cable from the converter RS422 Multi Drop The RS232 cable from RX the converter 3 In case of setting RS422 communication we recommend to use line end resistors of 120 Ohm between the RX and RX lines and between the TX and TX lines Apply the same resistors to the converter RS422 lines Consult a service center or an electric technician if you are not sure how to do it 4 When a multi drop communication doesn t work test one by one communication first 9 If the trouble remains after the procedure above contact a designated service center 55 EET Won Proximity T amp A Access Controller 14 FCC Registration Information FCC REQUIREMENTS PART 15 Caution Any changes or modifications in construction of this device which are not expressly approved by the manufacturer for compliance could void the user s authority to operat
40. lation between Input and Output Ce Input 1 Input 4 EXITBUTTON EXIT BUTTON FETA I oe EE A ee Input 4 Bms o o Reade DOK o o o Reader ID Eror o o 00 00 eReader IDTISEmor o o 00 00 Ca a A E Reader 2 ID OK Ree ao 00 12 Reader 2 ID T SEror o o w o 13 Reade2 APB Eror o o 00 MMIDURESSMODE o o 08 o 5 OUTPUT TIME SCHEDULE 00 00 00 Index No 1 14 The value indicates operation time second of each output for the input signal Index No 15 The value indicates time schedule code index that each output operation has to be applied Index No 16 The value indicates the time schedule code index that each input 1 Exit button 5 operation has to be applied 49 Star 505R B TROUBLE SHOOTING Proximity T amp A Access Controller i System operates abnormal Cause Of that user mistake memory SRAM is damaged or the system is defective of the device Solution 1 Check BAT connection Switch place template hole of reverse side You have to push up the Switch and system initialize before system installation SETTING A DIP SWITCH a m Before After Figure DIP SWITCH SETTING Figure DIP SWITCH LOCATION 2 If the trouble remains after checking the above contact a designated service center Broken or abnormal letters shown on the LCD when powered on Cause SRAM backup bat
41. lt value and data memory be clear ID data clear Event data clear Time Schedule data clear etc 4 Define IN OUTPUT value as intend and keep the main power on more than 5 days 9 If after all the above the problem remains please contact a designated service center A valid card became unregistered after batch downloading IDs from PC Cause Wrong procedure during download or a component defect Solution 1 The card ID might be registered only to the controller and not registered in the PC During the process of downloading IDs 505R first erase the ID memory of the unit therefore if the IDs from the PC didn t contain the card ID this can happen 2 Check whether the card ID Is registered in the PC 3 If not please register the number and try downloading again 4 f the trouble remains after the procedure above contact a designated service center t doesn t enter the Setup Mode after entering the Master ID 00000000 Cause The Master ID might have been changed or components are defective Solution 1 Try changing the Master ID through the application S W It ll be changed to 00000000 Note that the Master ID for SR505 is entering 10 times lt 0 gt 0000000000 2 When it is not feasible initialize the unit as following Press the two System Initialization switches simultaneously while power is on 91 ARI SUOR Proximity T amp A Access Controller Wait until the message Initialize END Turn
42. ode Approach card 12345678 q gt scanning Reade PW__TS_ RD Password 4 digits lt ENT gt Time Schedule codes lt ENT gt p Reader Usage codes lt ENT gt ID Registered Reg completed 2 Registration by Keypad PIN mode 12345678 9 gt p PW TS RD gt ID Sdigits lt ENT gt gt PW TS__ RD Password 4digits lt ENT gt Time Schedule codes lt ENT gt gt Reader Usage codes lt ENT gt ID Registered Reg completed 1 Scanning The reader is waiting for an RF card which has to be registered The card number will appear with a beep as the card is read ID number is a 8 digit number ID number of SR505 Is a ten digit number 2 1D ID number consists of 4 6 digits ID numbers Enter 4 6 digits ID numbers and press lt ENT gt key in the ID field When the Reader mode is PIN it is displayed on the LCD ID number of SR505 is a ten digit number 3 PW PW is the password which can be used to access the doors where you install a Proximity and Keypad Reader and setup the RF Password operating mode 24 Star 505R Proximity T amp A Access Controller But regardless of the operating mode it is necessary to enter a default password 0000 in the PW field when you register an ID 4 TS TS is the Time Schedule code 00 10 TS is the Time Schedule for the Reader 1 Reader 2 When you present the card to a Reader the cardholder is only allowe
43. on Proximity T amp A Access Controller 8 5 3 OUTPUT CONNECTIONS Door Lock Power Fail Safe Connection Relay 1 Connect COM wire of Relay 1 the Gray wire with Red stripe to 12V Connect NC wire of Relay 1 the Blue wire with White stripe to wire of door lock device Connect GND wire to wire of door lock devices Door Lock Power Fail Secure Connection Relay 1 Connect COM wire of Relay 1 the Gray wire with Red stripe to 12V Connect NO wire of Relay 1 the White wire with Red stripe to wire of door lock device Connect GND wire to wire of door lock devices Alarm Device Connection Relay 2 1 Connect COM wire of Relay 2 the White wire to 12V 2 Connect NO wire of Relay 2 the Purple wire to wire of Alarm devices 3 Connect GND port to wire of Alarm devices POWER POWER RELAY 1 RELAY 2 FAIL SAFE FAIL SECURE CoM gt NO gt a i omic A re DC 12 i POWER i DOOR LOCK Figure DOOR LOCK ALARM DEVICE CONNECTION CAUTION Please add one DIODE as shown above DIODE Fast recovery DIODE current Min 1A 1N4001 1N4007 or similar 8 5 4 EXTRA READER CONNECTIONS Proximity Reader Connection 1 Connect wire of the Proximity Reader to DC 12V 2 Connect wire of the Proximity Reader to GND of Power 3 Connect Data 0 wire of the Proximity Reader to DO the Pink wire 4 Connect Data 1 wire of the Proximity Reader to D1 the Cyan wire 17
44. or through the keypad 1 Card 2 Key For RF cards Press lt 1 gt key the keypad lt 2 gt key or you can quit the registration by pressing lt ESC gt key Scanning The reader is waiting for an RF card which is to be registered The card number will appear with a beep as the card is read After recognition the next message will appear MASTER ID CHANGE This figure appears when you press the lt 2 gt key for through keypad registration then you are to enter eight digit number L Eight digit ID 00000000 99999999 XXXXX Enter a new Master password four digits and finish changing XXX by pressing the lt ENT gt key Master The figure indicates that changing of the Master ID has been Card finished successfully The Master ID for 505R is 10 digits number Default setting 0000000000 12 1 8 SYSTEM INITIALIZE SYS INITIALIZE SF This is anid w us 1P TON i ee key if 1D resetting the event d a malfunction Xx CAUTION Initializing will erase all stored data in the memory Star 505R Proximity T amp A Access Controller SYS Press the lt 1 gt key to initialize or lt 0 gt key to cancel INITI the operation i This message appears while the system is being ee initialized Initializing After the initialization 505R will return to the Setup menu System 12 1 9 CARD ID CLEAR CARD ID When you want to delete all User IDs Card IDs you can clear all User IDs from the memory
45. ow wire of the 505R to RS422 RX port of the converter 2 Connect RS422 TX Grey wire of the 505R to RS422 RX port of the converter 3 Connect RS422 RX Blue wire of the 505R to RS422 TX port of the converter 4 Connect RS422 RX Brown wire of the 505R to RS422 TX port of the converter 9 Plug the RS232 9 pin connector of the converter into the COM1 or COM2 Port of the PC 6 Install and run the 505R Application Software RS 422 232 Fi Fn DOR To Star 505R To host PC a Between 505R and CNP200 b RS 422 port connection c CNP200 setting Figure RS 422 Communication between 505R and Host Computer 19 EEE SUOR Proximity T amp A Access Controller 9 2 2 RS 422 CONNECTION MULTIPLE 505R CONNECTIONS RS422 RS232 converter is required to use RS422 communication between multiple 505R and a host computer Please follow the following instructions First you have to connect all RS422 port of all 505Rs in parallel 1 Connect RS422 TX Yellow wire of one 505R to RS422 TX Yellow wire of another 505R 2 Connect RS422 TX Grey wire of one 505R to RS422 TX Grey wire of another 505R 3 Connect RS422 RX Blue wire of one 505R to RS422 RX Blue wire of another 505R 4 Connect RS422 RX Brown wire of one 505R to RS422 RX Brown wire of another 505R Second you have to connect one of RS422 port of 505R to RS422IRS232 converter 1 Connect RS422 TX Yellow wire of the one 505R
46. r the entire programming process Anti Pass Back IDTECK 6 EEE SUOR Proximity T amp A Access Controller By using an additional proximity reader the Anti Pass Back mode can be set The Anti pass back mode prevents entry or exit when the registered user did not properly followed one entry and one exit by the Anti pass back rule The same user can not enter twice with the entry card without properly using the exit before Input Output The Star 505R has 4 built in inputs and 4 outputs 2 relay outputs and 2 TTL outputs which can be used to manipulate a wide variety of controls Time Schedule Setup You can program 10 time schedules and apply one time schedule to each User Each time schedule has 8 different time zones from Monday Sunday 7 time zones and one holiday Each time zone has 5 different time codes so you can program 5 different time codes to each day You can also program time schedules for individual inputs and outputs Note that the time schedule for input is activated time code for input device so that the input is activated during the time code on this time schedule Each time schedule is linked to one holiday schedule and this linked holiday only validates to the holiday time code of the time schedule Holiday Schedule Setup Excepting Sunday you can program 32 holidays to one holiday schedule Each holiday schedule is linked to one time schedule which has a time code for holidays You can program all holidays to a holid
47. rly connected to the earth and floated from the IDTECK 12 Star S SR Proximity T amp A Access Controller ground level then grounding to the chassis ground will give the worst communication in this case we recommend to using power ground instead of chassis ground R5422 Rs232 Converter a R5422 is War Earth Ground or Chasis Ground or Power Ground SOSR 1 SOSER 2 Figure Grounding system 7 2 4 REVERSE DIODE CONNECTION If you connect an inductor Door Locks or Alarm device to the output relays there will be a high surge voltage created while the inductor is turning on and off If you do not connect reverse diode the surge voltage will transfer and damage to the electronic circuit of the controller It is strongly recommended to add a reverse diode between the inductor coils to absorb this surge voltage DC il Cathode Anode S05R DC y IN4004 1N4007 or equiv Lock Alarm Figure Reverse Diode connection 13 EET Won Proximity T amp A Access Controller 8 Installation 8 1 DIMENSIONS Unit mm inch 4 G amp G CE y CB CO rs Cesc CQ Cent ra 150mm 5 9 x 120mm 4 72 x 39 5mm 1 55 8 2 BACKUP BATTERY DIP SWITCH star 505R has a switch for the backup battery connection which remains open circuit to prevent any current consumption of the backup battery Figure Switch setting Before the Star 505R operation it needs to be
48. second 100ms in the in out define OUTPUT TIME SET Ex In order to have the relay 1 Out 1 operate for 3 second gt 100ms responding to the exit button input set as follow Define 1 Exit amp Relay as 03 in IN OUT define Define the OUTPUT TIME SET as second Ex In order to have the relay 1 Out 1 operate for 0 3 second responding to the exit button input set as the following Define one Exit amp Relay as 03 in IN OUT define Define the OUTPUT TIME SET as 100ms 39 Star 505R 12 3 SETUP MENU F3 p gt SEARCHING KEY lt 4 gt or lt 6 gt p P ID REGISTRATION t Key lt 4 gt or lt 6 gt ID DELETE Key lt 4 gt or lt 6 gt ID LIST t Key lt 4 gt or lt 6 gt REGISTERED ID COUNT A Key lt 4 gt or lt 6 gt ID COUNT 40 gt CARD KEY gt ENTER ID 8 digit key in gt DISPLAY REGISTERED ID gt DISPLAY REGISTRATION ID COUNT ENTER POSSIBLE REGISTRATION ID COUNT A ID EVENT 500 7 250 1 000 7 000 1 500 6 750 2 000 6 500 2 500 6 250 3 000 6 000 9 000 3 000 9 500 2 750 10 000 2 500 roximity T amp A Access Controller Star 505R Proximity T amp A Access Controller 12 3 1 CARD REGISTRATION ID REGISTRATION lt ENT gt ___ gt REGISTRATION SELECT CARD or KEY CA
49. stallation Layout 7 1 2 RECOMMENDED CABLE TYPE AND PERMISSIBLE LENGTH OF CABLE Maximum Reference Description Cable Specification Distance 505R Power DC12V Belden 9409 18 AWG DC Power gt 505R 2 conductor unshielded oy Reader Power and Data Belden 9512 22 AWG 150m Extra Reader gt 505R 4 conductor shielded 10 IDTECK Star 505R Proximity T amp A Access Controller Belden 9514 22 AWG A e Door Contact Belden 9512 22 AWG Sensor Input Belden 49514 22 AWG Lock Alarm gt 505R 2 conductor lied RS232 Cable Belden 9829 24 AWG Converter gt Host P C 2 twisted pair shielded RS485 Cable Belden 9829 24 AWG 505R gt 505R Sn 2 twisted pair shielded 505R gt Converter RS422 Cable 505R gt 505R 505R gt Converter Belden 9830 24 AWG 3 twisted pair shielded Need thicker wire if you connect the reader with high current consumption 7 2 CHECK POINT DURING INSTALLATION 7 2 1 TERMINATION RESISTOR Termination resistors are used to match impedance of the network to the impedance of the transmission line being used When impedance is mismatched the transmitted signal is not completely absorbed by the receiver and a portion of signal is reflected back into the transmission line The decision whether or not to use termination resistors should be based on the cable length and data rate used by the communication system For example if you use 9 600 baud rate and 1 200m length of
50. t 01 20 09 00 33 b gime 0 PNI L select ID COUNT Initial Display ID COUNT NI ENTER ID COUNT a gt 5 000 10000 ae Enter the number from 500 to 10000 ID COUNT STAR 505R F1 oo eE 10009 01 20 09 01 16 You will see this error message when you press EVENT MEMORY lt ENT gt key in the ID COUNT menu It tells you NOT EMPTY that some events are still existing in the EVENT Buffer and you may lose the data if you change the ID COUNT You may try this setting again after uploading the events to the host PC or deleting them using the SETUP MENU F1 EVENT CLEAR i You will see this error message if you try to change ID TOTAL COUNT ID COUNT less than the total registered User IDs Wrong In this case you have to delete some User IDs or clear them all using the SETUP MENU F1 gt ID CLEAR first then try again from the beginning 10 5 ID REGISTRATION You can register the User ID into the 505R Select SETUP MENU F3 gt ID REGISTRATION and follow the steps below The Master ID for SR505 is a ten digit number Default setting 0000000000 STAR 505R F1 MASTER ID lt ENT gt gt Press T3 hen Select gt 01 20 09 01 23 b gime gen ID REGISTRATION IDTECK 23 EET Won Proximity T amp A Access Controller Initial LCD Display ID REGISTRATION p ID REGISTRATION ENT gt 1 Card 2 Key 1 Registration by RF Cards RF only mode RF PW m
51. tery problem or LCD module problem Solution 1 Initialize the controller Connect the cyan wire pink wire and black wire together Switch the main power on Enter key lt 1 gt Check if the LCD shows the message Initialize END turn off Power Switch main power OFF Separate 3 wires pink cyan and black GND Switch main power ON again Aware that all the setting values will be back to the default value and data memory will be cleared ID data clear Event data clear Time Schedule data clear etc Set up the date and time on SETUP MENU F1 gt SYS INITIALIZE and SETUP MENU F1 gt TIME SETTING If you still have problems please contact a designated service center NO Go 90 EET SUOR Proximity T amp A Access Controller i Randomly changed value of in out define from previously setting value after power reset Cause Discharge of RAM Back Up battery Problem during the main power off Solution 1 Check if the Back Up Battery Jumper has been shortened 2 Check if the voltage of Back Up Battery is over 3 6V 3 If it is over 3 6V make initialization process as below Connect the cyan wire pink wire and black wire together Main power ON Enter key lt 1 gt Check if the LCD shows message of Initialize END turn off Power Main power OFF Separate 3 wire pink cyan and black GND Main power ON again Aware that all the setting value be back to the defau
52. the main SETUP MENU You can scroll up and down the SUB MENU by pressing the lt 4 gt and lt 6 gt key in the main SETUP MENU If you don t press any key for 60 seconds or if you press lt ESC gt key 505R will exit the SETUP MENU and return to normal operation In the case of SR505 Press ten times the lt 0 gt key Default setting 0000000000 to enter the SETUP MENU IDTECX 26 Star 505R Proximity T amp A Access Controller 12 1 SETUP MENU F1 gt READER 1 MODE RF Only DEFAULT RF P W PassWord key lt 4 gt or lt 6 gt PIN 4 6 Digit LL RF P W PassWord key lt 4 gt or lt 6 gt READER 2 MODE gt RF Only DEFAULT p PIN 4 6 Digit TIME SETTING lt 15 digit key in key lt 4 gt or lt 6 gt p SEARCHING KEY APB SETUP NOT USE DEFAULT lt 4 gt or lt 6 gt m USE key lt 4 gt or lt 6 gt op ALL CLEAR COMM ID key lt 4 gt or lt 6 gt BAUD RATE p 4800 m 9600 DEFAULT key lt 4 gt or lt 6 gt 19200 r 38400 EVENT CLEAR YES A NO key lt 4 gt or lt 6 gt y MASTER ID CHANGE CARD l a IDTECK SEE Won Proximity T amp A Access Controller A ke
53. ther registration repeat the process To end registering the days press lt ESC gt key to return to the setup menu 12 2 3 DEFINING OUTPUTS IN COMPLIANCE WITH INPUTS 37 Star 505R Proximity T amp A Access Controller IN OUT DEFINE lt ENT gt gt DISPLAY CURRENT SET SR A SELECT INDEX USE 4 6 KEY lt ENT gt Vv ENTER NEW TIME OR T S INDEX 10 DIGIT OR EVEN DIGIT ENT NO or lt ESC gt YES or Error You can program or deactivate each output to be generated IN OUT l and choose how long in seconds they will last There are DEF NE default values as seen in the table 2 below 1 EXIT s Select input sources by changing Index numbers with the keys lt 4 gt or lt 6 gt Press lt ENT gt key and you will see a cursor blinking at the first digit from the left of the five couples of digits which corresponds to Relay1 Relay2 03 00 00 00 OO TTL1 TTL2 and Buzzer respectively Enter the delay times refer to the table below one by one An input output definition has been completed now For further definition repeat the process To end defining inputs outputs press lt ESC gt key and you will see the first figure of the menu Note The five couples of digits of Output T S 15 and Input Output T S 16 are time schedule indexes 12 2 4 HOLIDAY INDEX SETTING Holiday Index is to link the Holiday Schedule H S to Time HOL I DAY Schedule Yo
54. ther countries please contact the local distributor To obtain in or out of warranty service please prepay shipment and return the unit to the appropriate facility listed below U S BRANCH RF LOGICS Inc 370 Amapola Ave 106 Torrance CA 90501 Phone 310 782 8383 Fax 310 782 8298 E mail rflogics rflogics com Web site www rflogics com HEADQUARTERS IDTECK CO LTD Service Center oF Ace Techno Tower Bldg 684 1 Deungchon dong Gangseo Gu SEOUL 157 030 KOREA Phone 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com Web site www idteck com Technical Support in korea E mail webmaster idteck com Hotline 82 19 264 7550 Customer support 82 17 340 4170 R amp D Please use the original container or pack the unit s in a sturdy carton with sufficient packing to prevent damage include the following information 1 A proof of purchase indicating model number and date of purchase 2 Bill to address 3 Ship to address 4 Number and description of units shipped 9 Name and telephone number of person to contact 6 Reason for return and description of the problem NOTE Damage occurring during shipment is deemed the responsibility of the carrier and claims should be made directly to the carrier IDTECK 97 Star 505R Proximity T amp A Access Controller 16 RMA Request Form RMA REQUEST FORM ORIGINAL IDTECK IDTECK Co Ltd yes ID CASH POINT
55. u can setup one Holiday Index 01 10 to one INDEX of T S Index 01 10 so that the Holiday Time Code in the T S can be applied for the holidays in the H S Default HOLIDAY CODE is 00 which means no holidays are T S INDEX applied to T S select HOLIDAY INDEX menu and press lt ENT gt Select 01 desired T S INDEX 01 10 by pressing the lt 4 gt or lt 6 gt key and press lt ENT gt key to input a 2 digits HOLIDAY CODE Press lt ENT gt to finish the setting 12 2 5 READER TIME SCHEDULE SETTING 1D MODE INDEX 00 i f you seg the RFtPASSWORD operating mode Refer to MODE SELECTION you can apply the Time Schedule for MODE INDEX During the time period of Time Code in the T S Reader 1 will operate on RF ONLY mode The rest of time neriod Reader 1 will operate RF tPASSWORD EET Won Proximity T amp A Access Controller MODE INDEX 00 12 2 6 LCD DISPLAY TYPE SETTING LCD DISPLAY This function is to set STATUS CARD NUMBER the card STATUS reading from the Proximity and Keypad Readers STATUS The Fixed message Is displayed on the LCD when card reading from the reader LCD DISPLAY CARD NO The card number is displayed on the LCD when card gt NUMBER reading from the reader Default setting is STATUS 12 2 7 OUTPUT TIME UNIT SETTING i This menu is to define time unit of 5 output ports OSTEUT TIME SET 1sec define time of output by second in the in out define 1sec 100 ms define time of output by 0 1
56. wo digit number then the setting is completed SETTING For the next setting use lt 4 gt and lt 6 gt keys Possible ID is between 00 31 inclusive 12 1 5 BAUD RATE SETTING ICON100 supports 4800 9600 19200 and 38400bps of oA RAIE baud rate and default setting is 9600bps Wrong baud rate 9600 setting will cause communication errors and you have to set same baud rate to iCON100 and host PC If you have communication problem BAUD RATE please check followings gt 9600 Check COMM ID of iCON100 and host PC Check BAUD RATE of iCON100 and host PC Check communication port and cable BAUD RATE Check COM port setup of host PC gt 19200 Parity None Data Bit 8 bit Stop Bit 1 bit To change the baud rate press lt ENT gt key and select desired baud rate by pressing lt 4 gt or lt 6 gt key then press lt ENT gt key 12 1 6 EVENT CLEAR ID court you can clear the event memory in this menu Press lt ENT gt key then press lt 1 gt key to clear event memory or lt 0 gt key to cancel the operation CAUTION Before you clear the events make sure that 1D EVENT CLEAR Star 505R Proximity T amp A Access Controller EVENT CLEAR 1 Yes 0 No 12 1 7 MASTER ID CHANGE Press lt ENT gt key to change the current Master ID NR NGE You should use the new Master ID to access the setup menu since the change is finished Master ID Number is registered in the controller by RF cards MASTER ID CHANGE
57. y codes are 1 for Sunday 2 for Monday 3 for Tuesday 4 for Wednesday 9 for Thursday 6 for Friday and 7 for Saturday The Master ID for SR505 is a ten digit number Default setting 0000000000 cc 99 p MASTER ID lt ENT gt Press lt F1 gt STAR 505R F1 Select TIME SETTING gt 01 01 00 00 15 o S ENT Initial Display TIME SETTING YYYYMMDDnhmmssW gt gt lt ENI gt gt gt lt ENT gt gt 200301 200900005 Year Month Day Hour Min Sec Day TIME SETTING STAR 505R F1 lt ESC gt 01 20 09 00 00 LCD displays after time setting 10 4 ID COUNT SETTING 505R can register maximum 10 000 User IDs and you can select maximum User IDs to be registered into the 505R from 500 Users up to 10 000 Users by every 500 unit This ID COUNT setting is to configure maximum User ID to be registered into 505R and if you setup less ID COUNT 505R will increase the EVENT Buffer size to maximum The default ID COUNT is 5 000 Users and the default EVENT Buffer size is 5 000 It can be stored when you operate 505R off line select ID COUNT in the SETUP MENU F3 then setup the maximum User IDs to be registered into 505R Follow the steps to setup the ID COUNT IDTECK 22 Star 505R Proximity T amp A Access Controller The Master ID for SR505 is a ten digit number Default setting 0000000000 STAR 505R F1 MTER sn Press lt F3 gt lt 4 gt or lt 6 gt s g
58. y lt 4 gt or lt 6 gt SYSTEM INITIALIZE YES key lt 4 gt or lt 6 gt AG CARD ID CLEAR YES NO key lt 4 gt or lt 6 gt TIME SCHE CLEAR gt YES key lt 4 gt or lt 6 gt NO RF PIN INPUT gt ENABLE gt DISABLE DEFAULT SEARCHING KEY key lt 4 gt or lt 6 gt lt 4 gt or lt 6 gt y EVENT MEMORY gt NOT USE key lt 4 gt or lt 6 gt gt USE DEFAULT DURESS MODE SET NOT USE DEFAULT USE key lt 4 gt or lt 6 gt A A DURESS P W SETTING FUNCTION KEY gt NOT USE DEFAULT A key lt 4 gt or lt 6 gt gt USE gt DATA BYTE TYPE gt 2BYTE ABYTE DEFAULT IDTECK 28 Star 505R Proximity T amp A Access Controller 12 1 1 READER 1 MODE SETTING READER 1 MODE a RF Only default key lt 4 gt or lt 6 gt Ld RF PASSWORD key lt 4 gt or lt 6 gt p PIN 4 6 Digit READER 1 MODE is set to RF ONLY operating mode REAMER DS If you want to change the mode to RF PASSWORD RF ONLY operating mode press lt ENT gt key READER 1 MODE Now you can change the mode by pressing the lt 4 gt or lt 6 gt key to toggle the mode If you want to setup the gt RF ONLY mode displayed press lt ENT gt key to accept this mode Note READER 1 MODE RF ONLY The door is accessible with the proximity card alone gt RF PASSWORD RF PASSWORD The door is accessible with the proximity card and Password PIN The door is accessible with the PIN number READER 1 MODE 4 6digits gt PI