Home
EZ PROX Manual 325Kb pdf
Contents
1. EV BPS al HUUU e o ke z al anmi E lock DC out Push button Timer NO GND PB Oj Q 0 20 secs eee z Z Yale Release fed FI Z e 240vAC INPUT Exit Button O How to enter programing mode Factory default programming code is 1234 Input the programming code twice 1234 and1234 the yellow LED will be on To exit programming mode press button Programming a fob or card Note Do not have Tags in your hand or close by when pressing keys EZ PROX has 1000 locations available from 000 to 999 Enter programming mode the blue LED will turn yellow Enter the location you want to programme the Tag to in a 3 digit format xxx A green light will show the location is empty and ready to present a tag if a red light is present this location is already in use To delete this location press the star key twice The LED will now turn green Pick up one Tag only and present it to the bottom of the reader and remove A bleep will be heard this means the card or fob is added If further Tags are to be programmed select the next available location number xxx nN Ww Deleteing a fob or card Enter programing mode Enter any 3 digit number from 000 to 999 yellow light will blink during this process if the LED changes to red there is data stored green shows the location is empty Press twice to delete the stored location Press to
2. Contents EZ PROX and back plate EZ PROX programmer 10 x Tags Security Torx Tool Equipment required for controlling one door 12 volt DC power supply 2 amp minimum EV BPS Lock Magnetic EVML 250 Yale type keep 12 volt lock enter D Push to exit button EVEXIT Green break glass emergency release EVEBG Note for use with Magnetic lock only Functions of the EZ PROX The EZ PROX can control one door by use of tags Programmable door open time 00 to 99 seconds 1000 Tags can be programmed Door closed function contact required Programmable rear tamper Internal buzzer for tamper monitoring auto cut off after 1 minute Sighting Of The EZ PROX The EZ PROX must not be located within 2 meters of any reader keypad type devices The EZ PROX must not be sited back to back with reader keypad type devices Site the EZ PROX within easy access to the door doors to be controlled Fitting Using the template mark and drill the fixing and cable entry holes Remove security screws from the underside of the reader and remove back plate Fit and secure the back plate in its final position See Fig below Feed the cable from the reader though the centre hole of the back plate Clip the top of reader onto the back plate and secure using the security fixing screws located on the underside of the reader Make all wiring connections and connect 12 volts DC to the reader The power LED will now be illuminated on th
3. e front of the reader Hole Screw anchor S A I Back cover Indicator Screw Hole e ae 114mm oS SS Bell button 5 G Screw Screw L E 1 Screw 200 Temm T Screw Remote control IR sensor Wiring Diagram Red power DC input 12V 24V Black power J AC input 12V 24V Brown door status detecting reed switch Orange push to exit button Yellow DATA 1 Green GND Blue Door bell Purple Door bell Gray DATA 0 White NO 1 Pink COM 1 Aqua NC 1 Shielded ground A We m Red DC input 12V 24V Black oJ AC input 12V 24V Brown o Door magnet Orange 60 Buttoni Yellow DATA 1 Green GND Blue Purple DC Gray DATAO 05D390K White NO 1 t Pink COM 1 o cel Aqua NC 1 a Shielded ground Wiring Diagram for Maglock EV BPS al HUUU e o fe o 2 8 OnnWAnNnnN 4 E lock DC out Push button Timer NC GND PB Oj 0 20 secs Maglock Capacitor 0 47uF N C PINK Emergency door release 240vAC INPUT Exit Button O Wiring Diagram for Yale Release
4. key followed by 9 key the orange LED will now flash 3 Press 04 a long bleep will be heard 4 Enter the length of the pin number you require 2 3 4 5 or 6 If the length is the same as already programmed you will get a conformation bleep If you have changed the length you will get 7 bleeps to say it has now been changed Note Any pin numbers or Tags programmed into the system will be deleted if the pin length is change Press to exit the setting mode Technical Specifications Working temperature 10 55 C Voltage DC 12V 24V AC 12V 24V Working current lt 120mA Standby current lt 90mA Card mode ID IC card Effective distance lt 5CM Capacity 1000 Cards or Fobs Elite Security Products Fax 01527 515143 Tel 01527 515150 email info espuk com Wwww espuk com
5. quit setting mode Programing a group of fobs or cards Enter programing mode All tags to be programed as a group must have consecutive numbers Press the key then the 9 key the yellow light will flash Press the 0 key then the 1 key the unit will bleep once Enter the number of the first available location in the range of 000 to 999 Now enter in a 3 digit format how many tags you want to programme xxx into the system present the lowest number tag to the reader and remove Alternatively enter the 8 digit number of the lowest number Tag from the group to be programmed into the keypad To confirm the programming has been successful 2 bleeps will be heard Press to exit the setting mode PWN v Set door open time 1 Enter programming mode A Long bleep will be heard and the blue power LED will turn yellow 2 Press the key then the 1 key the yellow LED will start to flash 3 Enter the time in seconds for the unlock time from 00 to 99 seconds Press to exit the setting mode The tamper alarm The built in buzzer will sound a continuous Bleep Bleep If the photoresistor sensor is directly exposed to the light The buzzer will turn off automatically after 60 seconds or when the light is no longer detected or by entering the programming code Changing the Programming code 1 Enter programming mode A Long bleep will be heard and the blue power LED will turn yellow 2 Press key followed by
6. the 3 key the orange LED will start to flash 3 Enter the new programming pin twice A conformation bleep will be heard 4 Press 3 yellow light blinks Then input new administrator code twice The length of the new admin code must be the same as the old one Bleep sound means it modifies successfully Press to exit the setting mode Turn on off the rear tamper alarm The rear tamper function consists of a photoresistor at the rear of the unit When this function is enabled the unit will emit a continuous bleep if exposed to light The continuous bleep will stop automatically after 60seconds or if the unit is no longer exposed to light You can cancel the continuous bleep by enter the programing code 1 Enter programming mode 2 To turn on the rear tamper alarm Press then 6 the yellow light will flash Press O then 2 the yellow light no longer flashes and the unit will bleep Press to exit the setting mode Delete all user fobs and cards and restore to factory default Enter programming mode 1 A Long bleep will be heard and the blue power LED will turn yellow 2 Press key followed by the 8 key theyellow LED will start to flash 3 Press the 8 key twice 7 conformation bleeps will sound Set the digit length of password 1 Enter programming mode by entering the 4 digit pin number twice default pin 1234 A Long bleep will be heard and the blue power LED will turn yellow 2 Press the