Home

Data Sheet - AceCom Networks Pte Ltd.

image

Contents

1. Cell Site De Cell Site Da 100000000 a Cell Site eo MTSO aS ES Switch Cell Site Cell Site Cell Site F a multiplexers AceCom etworks INL HA ril ci i lki Lot Technical Specifications DACS Control Card Processor Timing and TSI Card Part No VCL MX 1500 DXC Control Card Redundancy Processor 1 1 Redundant ARM7 Self Learning Self Healing Automatic Fail Over and Recovery 1 1 Redundant Self Learning Self Healing Automatic Fail Over and Recovery Timing and TSI OAM Management Interface Card Part No VCL OAM 1490 5 0 e COMPort RS232 Serial Port e USBPort e 10 100BaseT Ethernet Port Each multiplexer may be assigned an IP address and connected to a LAN IP network for remote access and management through the 10 100BaseT Ethernet Port for out of band configuration management and access Telnet SSH SNMP V2 e Windows based GUI Graphical User Interface for easy configuration management and access T1 Interface Card Part No VCL MX 1520 T1 5 0 Maximum number of interfaces 80 T1 Interfaces with full capability to cross connect at DS O 64Kbps time slot level as well as to inter connect to voice and digital data services between 80 incoming T1 Ports i e 80 separate T1 Links 1920 DS 0 any to any time slot cross connect Number of Interfaces per T1 Interface Card 8 T1 Interface
2. IP network for remote access and management through the 10 100BaseT Ethernet Port for out of band configuration management and access AceCom Netwo i a The OAM card supports A Telnet B SSH C SNMP V2 D Additionally a Windows based GUI Graphical User Interface for easy configuration management and access The VCL MX has an effective CLI text and GUI based Network Management Interface which may be used for configuring and monitoring multiple systems from a single central location Status Monitoring Synchronization Clock Selection Status of alarms Enabled Disabled status of 1 544 Mbps T1 Ports Monitoring the 80 Port T1 DACS status and configuration Monitoring of T1 Link status LOS LOF AIS RA Alarm Status and Monitoring e Loss of incoming signal at all 1 544 Mbps T1 Ports e Configuration error alarm LED Indication 1 to 80 T1 Ports LED indicators 5V DC present 48V DC present Configuration error External Alarm Contact Closures e 1 Alarm relay Type Form C AceCom Networks Application Diagrams ISP Digital Cross Connect Application Providing Fractional T1s to Subscribers Fractional T1 Channels PITEEUEEEEEEE Fractional T1 Fractional T1 Router Miiiiite Fractional T1 VCL MX Version 6 DXC Aggregates Fractional T1 Channels to a Single T1 Backhaul Cellular Application using VCL MX Version 6 DXC 80 T1
3. external adapter is an optional for AC mains operation Key Features and Highlights e 120Mbps 80 T1 fully non blocking cross connect at 64Kbps DS 0 level 1920 DS 0 any to any time slot cross connect Scalable from 8 T1 Ports to 80 T1 Ports 1 1 Control Card Processor Redundancy 1 1 Cross Connect TSI Redundancy 1 1 Timing Synchronization Clock Redundancy 1 1 48V DC Power Supply Redundancy Dual Power Input allows the equipment to be powered from two separate 48V DC sources Bit Error Rate BER monitoring BER thresholds to generate BER alarms automatically whenever alarm limits are exceeded Telnet remote access SSH for secured remote access SNMP traps Maintains Access Security Log USB and RS232 Interface for local connection through the serial interface to the Network Control and Management Software User Selectable Internal External and Loop timed clock synchronization priority options e Local and remote loopback facility System Access Control and Management Options Telnet SSH CLI Control Interface HyperTerminal or VT100 SNMP V2 Traps MIB File provided GUI Graphical User Interface AceCGom Netw or kd KS multiplexers i ft i rit facie HSS SIO OAM Operation and Management Ports e RS232 Serial Port USB COM Port 10 100BaseT Ethernet for remote access Security and Protection e SecuredAccess via SSH V2 e Password Protection Password Protection in compliance w
4. AceCom Netwo li i rks i l Ll JEA I CI AceCom Networks VCL MX Version 6 DXC 80 T1 120Mbps Digital Access Cross Connect Switch Product Brochure AceCom Networks Pte Ltd 200 Jalan Sultan 02 13 Textile Centre Singapore 199018 Phone 65 6295 3233 Fax 65 6295 3133 E mail sales acecomnet com Web Site http www acecomnet com Ace om Networks multiplexers I RTTE TERE m i _ er i ae i i i CHIL IA cht Ce LSL HSS Product Overview The VCL MX Version 6 DXC 80 T1 120Mbps Digital Access Cross Connect is a modular switch which may be scaled from 8 T1 Ports to up to 80 T1 Ports The VCL MX Version 6 T1 DACS T1 DXC offers full cross connect functionality to cross connect between 64Kbps time slots DS 0s n x64Kbps consecutive DS Os and Fractional T1 channels to full T1 channels L The VCL MX Version 6 DXC 80 T1 120Mbps Digital Access Cross Connect Switch occupies 6U high 264 mm rack space and is a complete 19 inch standalone unit that provides a 64Kbps time slot DS 0 cross connect fabric for up to 80 T1 ports This product offers 1 1 48V DC Power Supply Redundancy 1 1 Control Card and Processor Redundancy 1 1 Cross Connect TSI Redundancy 1 1 Timing Synchronization Clock Circuitry Redundancy This DXC offers user selectable clock timing synchronization priority The Dual Power Inputs allow the equipment to be powered from two separate power sources AC input
5. e 80 separate T1 Links 1920 DS O any to any time slot cross connect 10 Cards 80 Ports Max per Chassis 10 VCL 1505 TER DB37F RJ45F 16PP VCL MX Version 6 Upto 80 T1 120Mbps DACS DXC Cables amp Accessories Product Description 16xE1 T1 DB37 2 x DB37F to RJ45 16 x RJ45F Termination Panel 19 Metal case 1U High Rack Mount Version with Hardware Set VCL 1505 TER DB37F RJ45F 32PP 32xE1 T1 DB37 4 x DB37F to RJ45 32 x RJ45F Termination Panel 19 Metal case 1U High Rack Mount Version with Hardware Set VCL 1505 TER DB37F RJ45F 48PP 48xE1 T1 DB37 6 x DB37F to RJ45 48 x RJ45F Termination Panel 19 Metal case 1U High Rack Mount Version with Hardware Set VCL HRNS 1264 4E10 E1 T1 4 Port Connectorized Cable DB25M Open 1 cable each 4 Port E1 T1 card VCL HRNS 1268 8E1Y37M E1 T1 8 Port Y Connectorized Cable 2xDB25M DB37M 1 cable each 8 Port VCL 1505 TER DB37F RJ45F 16PP 10 UMIKitMXV6DXC System Core Cables Installation Accessories Documentation System User Manual Systems User Manual Disk etc Set Technical specifications are subject to changes without notice Revision 1 5 October 12 2012 AceCom Networks Pte Ltd 200 Jalan Sultan 02 13 Textile Centre Singapore 199018 Phone 65 6295 3233 Fax 65 6295 3133 E mail sales acecomnet com Web Site http www acecomnet com
6. ion Central Office Terminal and Remote Terminal are protected against power surges and transients occurring from lightning and electric induction as per CCITT Rec Table I K 20 towards line side Ordering Information VCL MX Version 6 Upto 80 T1 120Mbps DACS DXC Core Common Equipment 1 VCL MX 1500 DXC Product Description DACS Control Card Central processor cross connect and system control Card may be used in a 1 1 redundant Configuration Note Please order 2 numbers for 1 1 redundancy 2 VCL MX 1510 48V DC Input Power Supply Card May be used in a 1 1 redundant Configuration Note Please order 2 numbers for 1 1 redundancy 3 VCL OAM 1490 5 0 Management Card RJ45 DB9F COM USB OAM Operations and Management Card for connecting the multiplexer to be managed in a LAN allows the USER to assign a unique IP address to each multiplexer connected in a LAN to be managed from a single point Telnet SNMP V2 4 VCL MX 1506 19 Shelf 6U High Sub rack fitted with DB25F Connectorized Backplane Maximum Ten 10 traffic slots meant for tributary cards line cards VCL MX Version 6 Upto 80 T1 120Mbps DACS DXC User Configurable Interfaces 1 VCL MX 1520 T1 5 0 Product Description 8 T1 Interface Card Full capability to cross connect at DS 0 64Kbps time slot level as well as to inter connect to voice and digital data services between 80 incoming T1 Ports i
7. ith the mandatory clauses of the GR 815 CORE 2 specifications for secured access control e Logging Maintains a log of all successful and un successful attempts Logged information includes the ID and the IP address of the accessing entities Alerts the administrator if the un successful logging attempts exceed 3 e Security Audit All access logs for up to 30 days are maintained for security audit purposes e Security log entry of any request or activity including that user ID including IP address if applicable to establish user accountability e Report Generation Audit Trail e Security Administration System Overview and Architectural Details VCL MX Version 6 is a scalable DXC which may be used to cross connect at DS 0 64Kbps time slot level from 8 T1 Ports to 80 T1 Ports 120Mbps The VCL MX Version 6 DXC has a multi slot chassis with TDM backplane In the chassis there are ten 10 T1 interface card slots Each T1 Interface Card has 8 T1 Ports Two slots are reserved for 1 1 redundant control cards which includes the redundant cross connect processor TSI and clock synchronization timing functions One dedicated slot exists for an OAM card and two slots for 1 1 redundant power supply cards Chassis System Backplane All connections are made at the rear of the chassis providing interconnections between the various plug in cards and to the network VCL MX Version 6 80 T1 120Mbps Digital Access Cross Connect Switch suppo
8. rts high density T1 interface cards An extensive set of alarms for easy maintenance are provided in the system Timing Clock Synchronization Timing Options Internal Clock Loop Timed Clock External Clock User selectable synchronization priority Synchronization Sources Internal Clock span clock timing derived from incoming T1 links Loop Timed External Clock 75 Ohms TTL 1 544 Mbits and 100 Ohms Bits clock Default Option Internal Clock etw orks multiplexers Tle q PLICA cr System Management VCL MX Version 6 DXC 80 T1 120Mbps Digital Access Cross Connect Switch offers a variety of management options The equipment may be configured using CLI English text commands or a GUI Graphical User Interface The management and configuration commands may be executed from a VT100 terminal Windows HyperTerminal any DOS based system Linux or UNIX based system or Telnet remote configuration and management Power OAM Unused Control Supply 1 Card Slot Card 1 Master 10 Nos x 8T1 Interface Card Version 6 I to Power Unused Control Supply 2 Slot Card 2 Slave The equipment provides a wide choice of access ports for connecting to and executing management and configuration commands through its OAM Card The OAM card provides a COMPort RS232 Serial Port b USB Port C 10 100BaseT Ethernet Port each multiplexer may be assigned an IP address and connected to a LAN
9. s with full capability to cross connect at DS 0O 64Kbps time slot level as well as to inter connect to voice and digital data services between 80 incoming T1 Ports i e 80 separate T1 Links Connectors DB 25 RJ 45 RJ 48C Conformity electrical ITU T G 703 Frame Structure As per ITU CCITT G 704 Framing Options D4 ESF Selectable Line Coding AMI B8ZS Selectable Line Rate 1 544 Kbps 50 ppm Nominal Impedance 100 Ohms Jitter Tolerance ITU T G 823 ITU T 1 431 Monitoring Connection Line Quality Loss of Signal LOS Loss of Frame LOF All Ones Alarms AIS RA Remote Alarm AceCom Networks Power Supply Part No VCL MX 1510 48V DC nominal 36V to 72V DC 5V filtered 48V for terminal cards 4A at 48V DC Provided in the Card 4A at 48V DC Current limit 4A Recovers on removal of short Power Consumption Maximum Power Consumption 90 watts Environmental Working temperature 10 C 60 C for operation Relative humidity 95 R H non condensing Altitude Upto 9 000 feet Dimensions Height 266 mm 19 6U high Depth 21 0 MM Width 482 mm Weight 7 0 Kgs Regulation Compliance Meets CE requirements Complies with FCC Part 68 and EMC FCC Part 15 Class 2 Safety ULI 1459 Issue 2 Operation ETS 300 019 Class 3 2 Storage ETS 300 019 Class 1 2 Transportation ETS 300 019 Class 2 3 Protect

Download Pdf Manuals

image

Related Search

Related Contents

ZOB 590 Bedienungs- anleitung Einbau  2015-01-28_numero 1_2015_bresciaok  Polk Audio PSW10 Owner's Manual  Whirlpool ED19AK User's Manual    interrUttore eLettroniCo A SFiorAmento “2 FiLi” “2 Wire  Telex 804-100A User's Manual  18W Manual - Nature Power  the User Manual    

Copyright © All rights reserved.