1. All round navigation light 1 5150 T E l we V gt i C3 N 1 D 2 CO NI Ea 2 E L O E Lo 146 _Min100 i lO o gt 1 MONTERING MOUNTING CU NOTE All measurements in millimeters All tolerances 1mm f i Minimum measurements indicated by an asterix 146 285A12069 A B C D E p G Xx Y TEF 2850 Navigation light lt B 2 gt 250 225 gt C 2 95 0 026 D 900 590 55 260 275 Recommended practical measurements A B C D E F G x YY Zz TEF 2850 Navigation light 500 250 225 450 84 900 590 55 260 275 LAMP REPLACEMENT WARNING DO NOT OPEN MAINTAIN OR SERVICE IN AN AREA WHERE AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT Use a 19mm wrench to screw off lid Twist off lamp and replace Screw lid back on Tightening force 10 nm TEF 2850 Ex NAVIGATION LIGHT USER MANUAL SPARE PARTS TECNICAL DATA Description Part No Light source B22 65cd 85W 220V 9400 001 Light source B22 65cd 85W 110V 9400 002 Light source B22 35cd 55W 220V 9400 003 Light source B22 35cd 55W 110V 9400 004 Mounting bracket for 1 pipe 2622 Mounting bracket for 2 pipe 2615 Lamp holder B22 5088 0010 Gasket junction box 5001 0041 Gasket top lid 5001 0040 Cable gland M20 Ex nR 6 5 14mm 5030 0000 Gland M20 5 10mm for restricted breathing test 5657 Tranberg AS Strandsvingen 6 P O Box 8033
2. Input voltage Light source Lamp base Power comsumption Ingress protection Cable gland Area of use Ex classification Operating temperature Certificate No Compliance standards Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com Powder coated aluminium lens of trough colored glass According to installed light bulb Max 230V 55W for vessels 20 50 meters 85W for vessels over 50 meters B22 55 85W IP56 M20 Ex nR 06 5 14mm Ex zone 2 and safe area x II3G Ex nR IIC Gc T5 52 C to 45 C EC type examination MED B 6820 issued by DNV Product quality system MED D 1497 issued by DNV PRESAFE 14 ATEX 5436X IECEx PRE 14 0055X Special conditions Resistance to impact is tested with reduces values according to IEC 60079 0 26 4 2 low risk of mechanical damage Directive 96 98 EC Annex A 1 item No A 1 6 1 and Annex B module B COLREG 72 as amended Annex 1 14 IMO Res A 694 17 IMO Res MSC 253 83 IEC 60079 15 2010 IEC 60079 0 2011 TRANBERG
3. N 4068 Stavanger Norway TRANBERG Tel 47 51 57 89 00 Fax 47 51 57 89 50 info tranberg com www tranberg com Reg no NO 986 926 909 MVA Declaration of Conformity We Manufacturer Tranberg AS Address Strandsvingen 6 Gausel Responsible representative Tranberg AS Address Strandsvingen 6 Gausel Declare under our sole responsibility that the Products Navigation Lights with Type designations TEF 2840 TEF 2850 TEF 2870 TEF 2898 application of Council Directive 96 98 EC of 20 December 1996 on Marine Equipment as amended by Directive 2009 26 EC issued as Forskrift om Skipsutstyr by the Norwegian Maritime Directorate to which this Declaration relates to conforms to the following Regulations Standards Annex A 1 item No A 1 6 1 and Annex B Module B in the Directive COLREG 72 as amended Annex I 14 IMO Res A 694 17 and IMO Res MSC 253 83 For assessment see e EC Type Examination Module B Certificate MED B 7473 issued by DNV e Product Quality System Module D Certificate MED D 1497 issued by DNV This Declaration is issued according to the provisions of European Council Directive 98 98 EC on Marine Equipment as amended by Directive 2009 26 EC Stavanger Date 2011 05 02 Updated 2011 05 12 Updated 2015 02 26 7 1 M 4 loxdhen Haeolel Torstein Rysstad Discipline Lead Electronics P O Box 8033 N 4068 Stavanger Norway P O Box 8033 N 4068 Stavanger Norway Material
4. manufacturer will in no circumstance be held responsible for such activity For your health and safety always use safety gear suited for the task Be certain to follow codes regulations and or specific procedures that are related to the installation INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION The navigation light should be installed according to IMO reg ulations and other relevant rules and regulations for electrical The navigation lights are supplied with galvanic isolators installations onboard ships These should be placed between the navigation lights and Consider the difference in material between the navigation the wall thus preventing corrosion to either There should light seawater resistant brass and the wall mast it is to be be used acid resistant stainless steel fixing screws bolts installed on Use galvanic isolators whenever there is a risk of Never paint the navigation light or any of its components corrosion Use only spare parts as described e Fix navigation light to mast ships structure using M10 bolts not supplied Use acid resistant screws bolts Tight firmly max 25 Nm TOOLS REQUIRED e Open junction box to install and secure electrical cable The cable must be clamped near up to the navigation light according to relevant rules and regulations for Regular tools required for installation e Wrench es suitable for selected M10 bolts for fixing electrical installations onboard ships navigatio
5. TEF 2850 Ex NAVIGATION LIGHT USER MANUAL IMPORTANT Read this instruction carefully before installing the product ees DO NOT OPEN MAINTAIN OR SERVICE IN AN AREA WHERE AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT WwW N wT ep Q 7 o TRANBERG OS a Tranberg AS PO Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TEF 2850 Ex NAVIGATION LIGHT USER MANUAL INTRODUCTION At intervals according to company routines the restricted breathing properties should be verified Remove stopping Thank you for purchasing this product plug at test port M20 See illustration below Connect For installation maintenance and assurance of a long life pressure meter vacuum pump and conduct test according of this product please follow this manual to IEC 60079 15 2010 23 2 3 2 1 1 Note M20 gland for connection of 5 10mm hose is included in shipment Note According to approval test of restricted breathing properties is not required CONTENT IN BOX The product is fully assembled and ready for installation SAFETY PRECAUTIONS Note that changes made to the product and or installation of components which do not conform to the approval may be a safety violation The
6. n light to mast ships structure e Connect electrical wires Max 2 5mm Strip length a 8mm Tightening force 0 6 0 8nm Connect ground wire e Flat screwdriver for opening junction box to M5 earth screw in junction box e 2 mm wrench for installing of cable gland e Screw on junction box lid Max tightening force 5 Nm Make sure that gasket is centered and covering the whole perimeter e Small flat screwdriver for terminating wires e External bonding conductor Connect bonding wire to point shown in illustration below MAINTENANCE INSTRUCTIONS Allround Navigation Light Sector Navigation Light Gasket for top lid and junction box shall be replaced at iz a intervals of one year Part No 5001 0040 and 5001 0041 ae Gaskets shall be of same type as originals One set of replacement gaskets are included in shipment e 19 mm wrench for opening top lid The navigation light should be inspected according to Company routines The manufacturer suggests regular check for water intrusion condensation which should be removed immediately When cleaning use only mild detergents Alcohol or petroleum based products may damage lens paint or plastic components TEF 2850 Ex NAVIGATION LIGHT USER MANUAL SCREENING DATA FOR SIDE Sector navigation light