1. INTERSPIRO AG www interspiro de G terstra e 47 CH 4133 PRATTELN SWITZERLAND TEL 41 61 827 99 77 FAX 41 61 827 99 70 E MAIL info interspiro ch INTERSPIRO Ltd www interspiro com 7 Hawksworth Road Central Park TELFORD Shropshire TF2 9TU UNITED KINGDOM TEL 44 0 1952 200 190 FAX 44 0 1952 299 805 E MAIL infouk interspiro com SCANDINAVIA ASIA PACIFIC MIDDLE EAST amp EXPORT SWEDEN NORDIC amp EXPORT SALES DIVISION www interspiro com Box 10060 S 181 10 LIDING SWEDEN TEL 46 8 636 51 00 FAX 46 8 765 48 53 E MAIL info interspiro com MALAYSIA NORDIC amp EXPORT SALES DIVISION www interspiro com 305 amp 305A Lorong Perak Taman Melawati 53100 KUALA LUMPUR MALAYSIA TEL 60 341058122 FAX 60 341053122 E MAlLinterspiro asiapacific interspiro com
2. INTERSPIRO DIVATOR CPD USER MANUAL GENERAL INFORMATION The Divator CPD is a warning device for low cylinder pressure Divator CPD consists of a Cylinder Pressure Sensor CPS and a Head Up Display HUD The Divator CPD improves diving safety with a flashing diode warning when the cylinder pressure drops below 55 bar or 800 psi The HUD interface with the diode is mounted on the front of the Divator full face mask Two advantages of the CPD are that it does not need a manual reset after the warning is activated and that it is buddy readable Even though it has been carefully designed and tested the CPD like all man made devices are subject to failures Only when it is used as a secondary warning device as an enhancement to the pressure gauge and or other warning devices does the CPD improve diving safety IMPORTANT INFORMATION i PLEASE OBSERVE THAT THE CPD DOES NOT RELIEVE THE DIVER THE RESPONSIBILITY TO CONTINUOUSLY MONITOR THE CYLINDER PRESSURE WITH THE PRESSURE GAUGE AT ANY SIGN OF DAMAGE SUSPICION OF VIOLATION OF SYSTEM INTEGRITY OR IF THE CPD DOES NOT BEHAVE AS IS DESCRIBED IN THE SECTION PRE DIVE CHECK OF WARNING DEVICE RETURN THE CPD TO THE MANUFACTURER FOR CONTROL AND REPAIR READ ALL DOCUMENTATION BEFORE USE WIND THE CORD ACCORDING TO THE ASSEMBLY INSTRUCTIONS Changes to this document necessitated by typographical errors inaccuracies of current information or improvements and chan
3. ccording to the requirements of EN250 3 TECHNICAL DATA Service free life 10 years Max operating depth 100 metres Max operating pressure 300 bar Operating temperature 40 C to 70 C Warning activation 55 5 bar The maximum tension load of cord and cord connections are approx 100 N 10 kg The CPD is designed and tested according to EN250 The CPD safety valve opens at 2 6 bar 4 CPD CONFIGURATIONS e CPD 1 20 m Divator MKII Including HP Connection 97193 01 to be mounted on Divator MKII Part number 89100 04 e CPD 1 45 m Adopted for hose 336 190 389 820 or 800 850 mm 30 34 inches hose Part number 89100 03 e CPD 1 75 m Part number 89100 01 5 USER INSTRUCTIONS PRE DIVE PROCEDURES Attaching the HUD on the Divator Mask E Attach the HUD and place the cord under the breathing valve IMAGE 1 2 Never force the HUD onto the facemask angle the device and gently push until it snaps on Non compliance may damage the facemask or HUD IMAGE 2 PRE DIVE CHECK OF WARNING DEVICE 1 Open the cylinder valve and closely monitor the HUD At least one flash should be seen when the system is pressurised If no flash was detected a full warning device function test should be performed Close the cylinder valve monitor the pressure gauge slowly depressurise the breathing circuit using the breathing valve drain button Between 50 and 60 bar or 700 and 840 psi the diode should start flashing The flashing should stop when
4. depressurized POST DIVE PROCEDURES Detaching the HUD from the Divator Mask k If necessary detach the HUD from the Divator Mask Tilt by pulling the HUD away from the visor using a finger IMAGE 1 A ATTENTION DO NOT REMOVE THE HUD AS SHOWN IN IMAGE 2 NEVER FORCE THE HUD OFF THE FACEMASK ANGLE THE DEVICE AND GENTLY PULL UNTIL IT SNAPS OFF NON COMPLIANCE MAY DAMAGE THE FACEMASK OR HUD 2 Clean the CPD with fresh water If necessary use a mild soap cleansing fluid Let the CPD dry in air 6 PERIODIC INSPECTION Periodic inspection should be performed once a year or when there is a suspicion that the CPD does not function properly 1 On a protocol to be filed make a note of the HUD identity number the identity number consists of year 2 digits week 2 digits and a serial number Follow the instructions in the section Pre Dive Check of Warning Device to perform a full warning device function test Do a full visual inspection of the CPD If there are any signs of damage or if the CPD does not behave according to this manual return the CPD to the manufacturer for control and repair 7 ASSEMBLY INSTRUCTION Certified service and maintenance staff should perform the following assembly instructions WINDING THE CORD AROUND THE BREATHING HOSE 1 Mount the plastic coil two to three turns around the breathing hose Adjust a suitable cord length from HUD to breathing hose Secure the cord to the breathing
5. ges of equipment may be made at any time without prior notice Always refer to www interspiro com for product updates document updates and service bulletins The guarantees and warranties specified in the conditions of sale are not extended by this Safety Notice 2 TECHNICAL INFORMATION The CPD consists of two components the CPS a high pressure mechanical sensor and the HUD a device mounted on the lower frame halve of the Divator mask containing the diode interface These two components are joined with an electric cord running along the breathing hose The flashing diode warning is activated when the cylinder pressure drops below 55 bar or 800 psi When the cylinder pressure drops below 10 bar or 145 psi the warning is automatically reset a manual power down is thus never necessary It is important that the cylinder valve is closed and that the breathing circuit is emptied after the dive to avoid draining the battery e Under normal use the CPD is designed and tested for 10 service free years The definition of normal use is 100 dives yearly with 6 minutes of flashing time each dive e The CPD is designed to be secure from leakage and has a built in safety valve e Under normal conditions the safety valve release bubbles when the diver is rising to surface e The CPS and pressure gauge must be connected to a pressure outlet with flow restrictor a
6. hose with the coil band two to three turns Release the cord from the coil band and extend the twining of the coil band an additional two to three turns around the breathing hose IMAGE 3 Continue to wind the coil band 2 Wind the cord around the breathing hose by straightening the cord and rotate the breathing hose around it IMAGE 4 3 At the breathing hose end nipple repeat the coil band winding from 1 above IMAGE 5 amp 6 4 Complete assembly by securing the cord to the breathing hose IMAGE 7 CPS ASSEMBLY INSTRUCTION 1 Mount the CPS to the secondary high pressure outlet Tools 22 mm U spanner torque 15 Nm INTERSPIRO NORTH amp SOUTH AMERICA www interspiro com info interspiro com muy THE NETHERLANDS 4 BELGIUM INTERSPIRO Inc www interspiro us com 10225 82nd Avenue PLEASANT PRAIRIE WI 53158 5801 USA TEL 1 262 947 9000 FAX 1 262 947 9020 E MAIL info interspiro us com CENTRAL EUROPE INTERSPIRO BV www interspiro nl Televisieweg 113 NL 1322 BD ALMERE NETHERLANDS TEL 31 0 36 5363103 FAX 31 0 36 5384809 E MAIL infobv interspiro com UNITED KINGDOM amp IRELAND AUSTRIA INTERSPIRO GesmbH www interspiro de Sternweg 20 A 8401 ZETTLING AUSTRIA TEL 43 0 313 557 333 FAX 43 0 313 557 333 22 E MAIL info interspiro de GERMANY INTERSPIRO GmbH www interspiro de Postfach 1220 D 76691 FORST BADEN GERMANY TEL 49 0 7251 8030 FAX 49 0 7251 2298 E MAIL info interspiro de SWITZERLAND