Home
LOGIQ™ 700Quick Start Guide
Contents
1.
2. PastExamDatai The Past Exam Data 1 menu is used to record the fetus s measurements from up to the past six exams e Femur length FL Biparietal diameter BPD Head circumference HC Abdominal circumference AC and Estimated fetal weight EFW Calculations from today s exam are filled in on this menu automatically To fill in the PAST EXAM DATA 1 menu 1 Type the exam s date 2 Type the exam s FL Type in the rest of the measurements You do not need to enter the decimal point 3 Press ROI Size to move to the PAST EXAM DATA 2 menu or to the next fetus s PAST EXAM DATA 1 menu _ Past Exam Data 2 D The Past Exam Data 1 menu is used to record the fetus s measurements from up to the past six exams e FL BPD e FL AC e FL HC and e HC AC Calculations from today s exam are filled in on this menu automatically To fill in the PAST EXAM DATA 2 menu 1 Type the exam s date 2 Type the exam s FL BPD Type in the rest of the ratios You do not need to enter the decimal point 3 Press ROI Size to move to the next fetus s PAST EXAM DATA 1 menu or press Exit to save and exit the New Patient Menu and return to scanning Ex 8 a 9 9 8 Fetal Trending Refer To General Measurements amp Calculations C Fetal Trending gt Fetal Trending Growth Graphs are produced for each fetus providing yo
3. 5 Softkey Displays and Controls UP DOWN WALL LT RT ie MAP FR RES Hz V 0 FR RATE Next PACKET FILTER FRAME COLOR SIZE M RES ODE AVG TH 10 OFF 66 Code A COLOR COLOR COLOR TAG TAG TAG SIZE POS OFF Auto Optimize ROI Size M Mode Angle Steer SV Gate Angle Correct Baseline 9 10 Velocity Scale 11 CF Color Flow 12 Doppler Gain and Auto Angle 13 PDI 14 PW Invert Doppler Mode Controls Direction 2227865 100 REV 0 Page 17 Refer To Image Optimize Chapter Doppler Mode Controls 1 Softkey Displays and Controls UP DOWN WALL SWEEP DOPPLER uve iris SPEED E Hz MEDIUM 32 Previous Next OPPLER QUICK SELECT DYN E TRACE RANGE CORREC ABOVE Previous Next DOP SPECTRL VIDEO TINT AVG INVERT OFF OFF OFF Previous Next TRIPLEX VSCALE QUICK SELECT gen RATIO PW 1 2 ABOVE 2 Auto Optimize 3 Volume 4 Angle Steer 5 SV Gate Size 6 Angle Correct 7 Baseline 8 Invert 9 Velocity Scale 10 Trackball SV Gate Position 11 Cursor 12 Doppler Gain 13 PW 14 Update 15 Spectral Trace Doppler Mode Controls Doppler Color Flow Mode Controls Doppler Color Flow Mode Controls Direction 22
4. Optimize Auto Optimize Direction 2227865 100 REV 0 Page 10 Refer To Image Optimize Chapter Auto Optimize B Auto Optimize AUTO optimizes the image based upon a specified region of interest or anatomy within O in Color Flow Doppler Modes press the B Mode image Color Flow ROI or Spectral Doppler in order to improve the contrast of the You can also activate AUTO via the AUTO softkey in displayed image data 8 m8 B Mode and in Doppler Mode 28 AUTO is available in single multi image on live frozen 8 9 or CINE images and while in zoom in Spectral i i Auto Optimize Doppler AUTO is not available on archived images AUTO Color Flow AUTO in Color Flow Mode optimizes the Color Flow ROI by adjusting the Color Flow or PDI maps and thresholds and PDI compression curves AUTO improves overall color sensitivity especially in low flow states This improves the color performance while reducing optimization time In AUTO Color Flow the baseline must be set at zero In PDI you cannot create an AUTO topographic map AUTO Spectral Doppler Optimizing AUTO B Mode to a selected ROl Anatomy AUTO in Doppler Mode optimizes the spectral data To optimize the image based on a selected ROI in B Mode AUTO adjusts the velocity scale PRF baseline shift 1 Click Previous Next to move to the second B Mode SoftMenu Click the AUTO
5. gt Obtain a sagittal and transverse image Use M12L or 739L probe for capsular flow with two focal zones Use MIN COL a symmetric velocity map SVI Medial Filter and post processing B Maps may improve contrast resolution Delete frame with shadowing or bright echoes No comments Use two to three focal zones Use a symmetric velocity map SVI Higher frame averaging may be helpful Lymph Nodes MIN MAX COL 0 5 1 5cm 0 5 1 5cm The numbered notes below apply to the number of the exam in the table above 1 Edit any images with shadowing 2 Sweep through network of ducts 3 Size ROI box to cystic structure Use a high contrast map and activate Median Filter 4 Median Filter or post processing gray maps for optimum contrast resolution 5 Sweep through network of nodes B Color may be helpful in improving contrast resolution On Biopsy exams use a 0 90 angle to see biopsy needle and tracks 3DView 3DView 3DView Hints Direction 2227865 100 REV 0 Page 28 Refer To Image Optimize Chapter C 3DViewHints Small Parts 3DView Recommended Settings OB 3DView Recommended Settings SWEEP SWEEP PROJECT LENGTH PROJECT LENGTH Thyroid OB Aorta Abdominal Thyroid Vessels 0 5 1 0cm Cord Testicular Insert 0 5 1 0cm Fetal Testicular Cerebral Vessels 0 5 2 0cm
6. Circle of The numbered notes below apply to the number of the exam in the table Willis 0 5 1 0cm above Fetal Face 1 0 2 0cm 1 Reducing Dynamic Range helps separate solid tissue or mass from FetalSpine 0 5 1 5 m surrounding vessels Fetal Humeral 2 See 1 above Head horoi 3 When evaluating a homogenous organ such as a testicle in B Mode or Color Flow use the Median Filter to see soft tissue better d The numbered notes below apply to the number of the exam in the table above Set Frame Averaging to 7 Lower color gain to image individual vessels Scan coronal Scan transverse or axial 26 30 week fetus Scan coronal or sagittal Include rib insert in editing CINE Loop Applies to fetal femoral head at 25 36 weeks as well Use small region of interest o 0g 3DView Hints Direction 2227865 100 REV 0 Page 29 Refer To Image Optimize Chapter S3DViewHints Vascular 3DView Recommended Settings SWEEP PROJECT LENGTH Carotid MIN Sagittal COLOR Carotid MIN Transverse COLOR MIN Carotid COLOR Venous MIN MIN COL Venous MAX COL The numbered notes below apply to the number of the exam in the table above 4 5 Depends on how the sweep of scan is performed Hints In Color Flow Velocity edit rendered CINE Loops removing the frames that are not needed
7. Trace Used to measure e Circumference e Area e 9 Stenosis Caliper Used to measure Distance e Time Depth Slope Velocity To trace an area of interest v 1 Press Freeze Press Trace Trace 2 Trackball to position the first Kaley cursor Press Trace again v 3 Trackball around the anatomy you want to trace 4 Press Set to complete the v measurement or let the trace auto complete Caliper To measure distance y 1 Press Freeze Press Caliper 2 Trackball to position the first v cursor Press Caliper again Set 3 Trackball to position the second cursor 4 Press Set to complete the measurement Direction 2227865 100 REV 0 Page 20 Taking a Measurement j To be prompted through a calculation 1 Press Freeze Press Calc v 2 Click the calculation softkey 3 Make required measurements v To assign measurements to a calculation INDEX 1 Press Freeze Press Calc E 2 Make required measurements 3 Click the appropriate softkey The calculation appears on the display and on the exam s worksheet ie o5 B Sa 8 Basic Measurements Refer To General Measurements amp Calculations Circumference amp Area Ellipse Used to measure circumference and area 1 Press Freeze Press Caliper 2 Track
8. i N eE Connecting CAUTION 1 Carefully remove probe from carrying case DO NOT let probe head hang free 2 Turn connector handle 2 to horizontal position 3 Place probe head securely into probe connector yoke 4 Align connector with probe port and carefully push into place Lower the control panel to connect AMA probes to the third probe port from the left 5 Turn connector locking handle to the full vertical position ll Fi Ei y gt Failure to lock the connector in place MAY CAUSE intermittent problems with probes already connected Activating Automatic upward until probe is free of probe holder Carefully slide probe away from probe holder and around control panel 1 Carefully lift probe Refer To Getting Started and Probes Chapters Activating Manual To manually activate a probe 618e 73917 1 Press Code S 2 Click PROBE ID softkey corresponding to desired probe To reset to automatic activation 1 Press Code S Click Previous Next 2 Click AUTO C Deactivating I B 1 Carefully slide probe V around control panel toward its probe holder Match the colored ring on probe to colored ring on probe holder Place probe into its prob
9. Also raise the Color Threshold to increase color detail In B Mode select different gray maps to obtain the best contrast resolution B Color is also useful to improve contrast resolution When vessel pulsatility is noted increase frame averaging If a vessel appears elongated in either direction on the 3D display use a shorter sweep length to improve the image or edit the number of frames in the CINE Loop Set the Frame Averaging to a higher level When using opaque color maps change the Color Threshold to 10096 In symmetric color maps the Frame Average is preset to 7 Hints continued The rendering time is dependent upon the number of CINE frames size of the 3D region of interest and choice of HI or LO RES and SHEAR reconstruction method The longer more frames the CINE Loop the greater the rendering time The larger the 3D ROI the greater the rendering time For cysts sweep in the plane with the cleanest edges Edit the CINE Loop to include only the mass Use high contrast maps Activate Median Filter The 3D rendering brings out the edges of the lesion much better than 2D Use SHEAR to quickly view the 3D volume of interest to verify that all parameters have been Set correctly On a biopsy exam use a 0 90 angle to see the biopsy needle tracks during multiple passes into the lesion In B Mode select different gray maps for the best contrast resolution B Color may be helpful in improving the contrast resolution of the
10. Caliper b Trackball to position caliper Press Set 5 The measurement and its resultant estimated fetal age are recorded onto the display and Biometry Worksheet CINE GS Measurement gt If you use CINE to measure the GS after obtaining images in two scan planes take three distance measurements then click GS Use ROI Size to move through CINE DO NOT exit calculations while taking measurements in CINE If you do exit via the CALC key the measurements are deleted lt Multiple Gestation _4 Starting an Exam 1 Press New Pt 2 Fill in exam information including the NUMBER OF FETUSES 1 4 Moving to Next Fetus While Scanning 1 Click FETUS X softkey where X indicates the letter of the fetus you want to scan Viewing OB Reports 1 Click the REPORTS softkey 2 Then click the softkey corresponding to the report you want to view Moving to the Next Fetus s Worksheet 1 Press ROI Size Editing the Number of Fetuses During an Exam 1 2 3 Press New Pt Press Return to verify that this IS NOT a new exam Trackball to NUMBER OF FETUSES 1 4 Type the number of fetuses If you decreased the number of fetuses specify which fetus s data needs to be deleted by clicking the appropriate DELETE FETAL DATA softkey Press New Pt or Exit to return to scanning OB Fetal Trending Direction 2227865 100 REV 0 Page 23
11. Click softkey up down 5g Coded Harmonics Coded Harmonics imaging utilizes Digitally Encoded Ultrasound DEU to enhance near field resolution for improved small parts imaging as well as far field penetration 1 Press Harmonics Release 8 0 EXPERT and Update Multi Frequency optimizes the probe s capabilities at multiple frequencies to image different patient types 1 Press Multi Freq 2 Click appropriate FREQ softkey Tissue Harmonic Imaging frequencies are preceded by a T Release 6 5 and 8 0 PRO Refer To Image Optimize Chapter Focus Number amp Position Optimizes image by increasing resolution for a specific area Qi Focus Position Focus Number B Mode Click up to increase click down to decrease Click up to move focal zone to near field click down to move focal zone to far field mI s C Depth B t 6 cm 14 cm Adjusts field of view to image deeper structures or structures near the skin line TGC Near Field Far Field lt gt Balances the image so brightness is consistent throughout image To decrease increase move slide pot to left right Gain 7 Changes overall image brightness To increase decrease turn dial right left Changing M Mode Gain does not affect B Mode image gain C
12. from wall or curtains drapes The Circuit Breaker is located at the back of the console on the left side It is used for turning off disconnecting all power to the system It automatically trips power to the system in case of power overload Power Power On Off Power On Off Direction 2227865 100 REV 0 Page 4 Refer To Getting Started Chapter OOO mu 0556 Power On Off CAUTION 4 The Power On Stand by switch is located on the front of the console on the left side To power on the system 1 Push the Power on Stand by switch up The following happens over the next several minutes 1 The control panel lights turn on then off 2 The system is initialized During this time LOGIQ 700 MR e Start up status messages scroll across the EXPERT Series e Relays click on and the LOGIQ 700 MR EXPERT or PRO screen appears Controls available for a particular mode are dimly lit controls not available for a particular mode are not lit Prior to turning off the system ensure that you have Made all necessary image worksheet and summary report hard copies e Waited until archive copy and delete commands have been completed all prints have been produced and that all queued DICOM jobs have been sent To power down the system 1 Push down on the Power On Stand by switch After power down each day e Disinfect probes Wait ten to fi
13. SoftMenus Tokyo FETUS A REPORTS AC FETUS A REPORTS ACCEL HEART AC A RATE AFI FL HC 2 3 Calculation REPORTS BED SoftMenus FETUS USER 2 UTERINE CRD A S D S D OB 1 PULSE RESIS INDEX INDEX FETUS USER USER4 USER 5 A USER 6 USER 7 OB SoftMenus Osaka FETUS BPD A REPORTS AFI HL CRD S D REPORTS USER 8 FETUS A FL UTERINE S D PULSE RESIS INDEX INDEX FETUS REPORTS CRL on Lv HEART RATE REPORTS ACCEL HEART UTERINE CRD RATE S D S D PULSE RESIS INDEX INDEX OB Exam OB Exam Direction 2227865 100 REV 0 Page 22 Refer To General Measurements amp Calculations L Gestational Sac Use the prompted method to take three distance measurements in two different scan planes to measure the gestational sac if you choose to do this measurement without using Multi Image 1 Click the GS softkey The first caliper appears 2 Take the first distance measurement a Trackball to position caliper Press Caliper b Trackball to position caliper Press Set The second caliper appears 3 Take the second distance measurement a Trackball to position caliper Press Caliper b Trackball to position caliper Press Set The third caliper appears Press Freeze to unfreeze the image Change the scan plane Press Freeze 4 Take the third distance measurement a Trackball to position caliper Press
14. Timeline To edit CINE Loop 1 Trackball to desired start position Click EDIT LEFT 2 Trackball to desired end position Click EDIT RIGHT LOOP EDIT CINE 3D SPEED LEFT STORE MODE 11 EDIT RIGHT Post Processing Available post processing controls VIDEO INVERT Images black on white COLOR MAP Cycles through color maps COLOR TAG Tags velocity range B Color Activates B Color Maps Gray Selects gray map Zoom Zooms region of interest Angle Correct Adjusts Doppler angle Baseline Adjusts Color Flow baseline Invert Inverts color map CF Removes color from Color Flow image Auto Optimizes Optimizes image spectrum To stop CINE Loop move the Trackball To exit CINE Loop press Freeze CINE CINE Timeline Comment Comment Direction 2227865 100 REV 0 Page 14 amp The annotation keyboard is always active Begin typing Press the lt T keys to point out a part of the anatomy To reposition annotation cursor Comment 1 Press Comment 2 Trackball to move cursor 3 Begin typing To revise existing text 1 Press Comment 2 Trackball to where you want to add change information 3 Typeover existing text or press Word Del Annotating D To delete previous character press Backspace To delete a word press Word Del To delete all comments Shift Press and hold down
15. mass Opaque maps tend to reduce noise in 3D Color Flow renderings In Color Flow Mode try to minimize great changes in vessel orientation Use a symmetric velocity map SVI to enhance color continuity Longer sweep lengths tend to create or appear to create greater separation of vascular structures Choose a sweep length that most closely represents the actual sweep length A sweep length selection larger or smaller than the actual size may cause a distortion of the anatomy When using opaque maps both MAX COLOR and MIN COLOR give the same result since no surrounding B Mode tissue is displayed For Surface rendered 3DViews activate B Color then adjust the window and color level to accentuate the surface of the anatomy to be rendered Then deactivate B Color if desired and render the 3DView 3DView VCR Recording N Recording an Image Direction 2227865 100 REV 0 Page 30 DIE v Record Pause v Mic 1 Insert tape into the VCR 2 Press Record Pause 3 Push the Microphone to record audio voice over if desired To pause recording 1 Press Record Pause To begin recording again 1 Press Record Pause To stop recording 1 Press Play Stop Reverse Fast Forward 1 v Play Record Stop Pause v Play Pause To reverse fast forward the tape VCR stopped image not displayed 1 Click REV FF to the left ri
16. 27865 100 REV 0 Page 18 Power Doppler Imaging Power Doppler Imaging PDI is a color flow mapping technique used to map the strength of the Doppler signal coming from the tissue rather than the frequency shift of the signal To activate deactivate press PDI Click COLOR MAP to cycle through power and topographic maps c Volume Controls Doppler Audio output increase decrease turn O dial right left ae 5 MN Angle Correct B Adjusts Doppler angle to correct the velocity scale lt To adjust angle click left right Or press Auto Angle Correct Or adjust QUICK ANGLE CORRECT softkey Cursor B Displays Doppler Cursor on B Mode image or in Update toggles between B Mode or Color Flow controls and Doppler Controls 1 Press Update 2 Press Cursor to toggle between Doppler and B Mode or Color Flow controls Doppler Gain gt Correct Amplifies received Doppler signals and Color Doppler inside color window Also Auto Angle To increase decrease turn dial N right ieft J Press down to auto angle Rotate dial to adjust auto Refer To Image Optimize Chapter Baseline m V Positions Doppler spectrum and Color bar baseline Click up down angle a C Angle Steer Slants the linear image left right to get more information without moving the probe Click lef
17. 6 Refer To Image Optimize Chapter CAUTION This 3DView application is designed for qualitative information only and has no provision for any measurement or computation ability also no specific reconstruction resolution is provided or claimed for this option No position information is collected for source scans used for 3D reconstructions and distortion or skewing will be introduced if frames are not acquired at a uniform rate or spacing Also acquiring frames by rocking the probe may create additional distortion due to the use of non parallel source images Remember that the 3D images created are intended for subjective evaluation only and may have distortion that is not obvious Auto 3DView D Press Auto 3D from a live image The Auto 3DView Preset SoftMenu appears the name of the last selected user preset appears on the display along with the 3DView ROI and the Update and Freeze keys blink Click the desired 3DView preset The preset SoftMenu disappears Position the 3DView ROI with the Trackball and size the 3DView ROI with ROI Size Press Update or the right foot pedal to start acquiring new 3DView data Perform a 2D scan of the anatomy Press Freeze or the left foot pedal to render the 3DView The 3DView is automatically rendered You may have to manually override the automatic Sweep Length setting determined by the System You can override this rendered 3DView manually or by selecting a
18. 8 Via the DICOM Status menu you can verify devices determine which jobs are in the queue for a particular device send jobs to a different device or delete jobs Refer to the DICOM chapter in the Advanced Reference Manual Starting an Exam Direction 2227865 100 REV 0 Page 9 Refer To Getting Started Chapter 0000 co Ret gt 6 To start a new patient exam Press New Pt 1 Cm Sein E em Starting an Exam Image Presets t Type a Y to verify that this is a new patient Press Return Trackball to select the appropriate exam category Press Set Exam Category determines presets available applications and worksheets Fill in appropriate patient data OR for DICOM users press ROI Size to go to the Worklist Schedule Trackball to select a patient then press Set The New Patient menu appears with the data filled in Press Exit Select the application Image Presets selects modifies creates archives or views System or user presets Remember user and factory defined presets are dependent upon the Exam Category and Application selected on the New Patient Menu and Image Presets softkey Select a probe Begin scanning To end a DICOM exam press End Exam This sends all queued images and partial print jobs to the specified device one job at a time Starting an Exam Auto
19. AOI VIDEO SMOOTH MEDIAN INVERT FILTER FILTER TINT 0 OFF B Flow UP DOWN ON OFF B B FLOW AUTO FR RES BCKGRND FRM RT ON 2 B Flow 8 0 EXPERT and Update 3 Auto 3DView 4 Coded Harmonics 8 0 EXPERT and Update 5 Multi Frequency and Harmonic Imaging 6 5 8 0 PRO Series 6 TGC 7 Focus Number and Position 8 Depth 9 Auto Optimize 10 Gain 11 ROI Size 12 Angle Steer B Mode Controls Image Quality Image Quality Acoustic Output Direction 2227865 100 REV 0 Page 12 Optimizes image quality and allows user to reduce beam intensity V WARNING A Acoustic Output Hazard Display Mechanical Index MI Soft Tissue TIS Thermal Index Bone TIB Cranial TIC Code To increase decrease 1 Click up down Read descriptions for each control you intend to use before adjusting Acoustic Output or any control that affects Acoustic Output Use the minimum output to get the best diagnostic image or measurement during an exam Values greater than 0 1 are displayed Mechanical effects cavitation on biological tissue produced by acoustic beam Thermal effects on soft tissue Thermal effects on tissue with ossified bone near the focal point of the beam Thermal effects on bone located near the surface such as the cranium To change display 1 Press Code X 2
20. Chapter C Back View 2 1 2 Storage Area Use the storage area to store the Quick Start VCR tapes endocavitary probe gel sheaths etc Peripherals Peripheral shelf for Release 8 0 Update and 6 5 The printer sets across the peripheral shelf The VCR can be set on top of the printer If the VCR is the only peripheral place it here Cord Wrap Wrap the cord around the Power Cord Wrapping fixture provided in the back of the unit Footswitch Storage Used to store the footswitch Connector Panel Used to connect peripheral devices to the system Power Cord and Circuit Breaker The Power Cord connects into the system here and the Circuit Breaker is located here Air Filter The Air Filter is located in the back of the unit Power Direction 2227865 100 REV 0 Refer To Getting Started Chapter dii Power ON E To connect the system to the electrical supply refer to the illustration WARNING 1 Ensure that the wall outlet is a dedicated 15 20 Amp branch circuit of the appropriate type depending on the system 2 Make sure that the system s power switch is turned off 3 Unwrap the power cable Make sure you allow sufficient slack in the cable so that the plug is not pulled out of the wall if you move the system 4 Push the power plug securely into the wall outlet Keep unit one foot 30 5 cm
21. ID OPERATOR ID DOB G RAVIDA P ARA A BORTION E CTOPIC GA or EDD OF FETUSES HISTORY REFERRING MD PAST EXAM DATA DICOM Note Press ROI Size Trackball to patient name on the Worklist menu Press Set to select Patient data is transferred to the New Patient menu OB Exam OB Presets d 2 1 Press Code P Page 1 of 6 2 Trackball to OB Calc Pkg Type Select US Tokyo Japan or Osaka Japan 3 Trackball to CUA Method Hadlock Select Average or Regression Hadlock BPD FL HC AC only 4 Trackball to Heart Rate Method Manual Select to calculate heart rate over 2 or 3 beats OB 2 3 FETAL GRAPHS Report 77 DOPPLER Soft enu FETAL summary ANATOMY BIO US 711 METRY FETUS HEART GS CRL A RATE REPORTS gs USER 1 2 3 GYN REPORTS FETUS UTERINE CRD A S D S D ACCEL PULSE RESIS INDEX INDEX REPORTS NI c Exam Reports gt Biometry Displays measurements gestational Worksheet a j ge growth percentile source wanatomy Indicates imaged anatomy Summary pj Report Displays pertinent exam information Multiple Displays each fetus s exam Gestation information Past Exam ets users enter past exam data Data via New Patient Menu OB Graphs Displays OB Growth Charts OB Doppler OB automatic vascular calculation Report worksheet OB 1 FETUS Calculation FL EZ SoftMenus US OB
22. INE CINE Timeline Direction 2227865 100 REV 0 Page 13 Refer To Getting Started Chapter ma C CINE Store Daan To store a CINE Loop or 3DView click CINE STORE v v Activating CINE CINE Timeline CINETimeline Useful for viewing short segments of an image timeline 1 Press Freeze 2 Trackball to activate CINE To cancel a CINE store click v He CANCEL CINE STORE 3 Trackball left backward or es 3 right forward to manually a To review the archived CINE move through CINE memory 1 CINE Gauge CINE Timeline memory window Loop OR 2 2 Timeline Icon Indicates current window of ae 1 Press Archive Menu timeline information in proportion to entire memory gt 2 Trackball to CINE Loop CINE memor 3 Frame Indicator Indicates position of B Mode segment image frame for this group of timeline vectors 3 Press Set to select The CINE Timeline gauge shows v your location in CINE memory A To activate B Mode CINE CINE Timeline only click 4 Press Return B Mode CINE frame counter B MODE CINE or TMLINE CINE softkey BEGIN 5 Click BEGIN LOOP REVIEW appears in the upper right hand EET corner of the display eol dee 9 P d REVIEW FRAMES EDIT DELETE RIGHT FRAME m CINE Loop Automatic review of CINE segment To activate CINE Loop 1 Click BEGIN LOOP REVIEW Not available for CINE
23. ISK MOD SNY UP 2900 DICOM device etc Press Exit to save H H F im er a H Direction 2227865 100 REV 0 Page 8 To Print To record the image onto the printer camera or disk v storage that has been preset 1 Press Freeze 2 Press P1 2 or Shift P1 2 SP1 2 An optional footswitch may be used to print images sent to P1 The displayed archive reference number IM indicates the number of the next image to be archived gt 18 8 Peripheral Setup Refer To Getting Started and DICOM Chapters C DICOM ND To set up DICOM 1 Ensure that the network is physically connected 2 Configure the LOGIQ 700 to the network via Code P Page 4 of 6 3 Set up each DICOM device via Code the Device Configuration menu Make sure to activate the device 4 Tie each DICOM print and storage device to a print key via Code P Page 5 of 6 5 Set up Worklist search display criteria via Code N the Worklist Setup menu Make sure to at least search on the patient s first and last name date of birth gender ID and exam Accession Number To monitor control DICOM devices Press Code N The DICOM Status menu appears Store 1 CTN Oo Codonics
24. LOGIQ 700 Quick Start Guide CE cess GE Medical Systems Direction 2227865 100 Revision 0 Copyright 1999 by General Electric Company User Documentation REVISION HISTORY DIRECTION 2227865 100 REV DATE REASON FOR CHANGE 0 May 21 1999 6 5 and 8 0 Releases LIST OF EFFECTIVE PAGES PAGE REVISION PAGE REVISION PAGE REVISION NUMBER NUMBER NUMBER NUMBER NUMBER NUMBER Title 0 1 30 0 Revision History 0 Back Page N A Please verify that you are using the latest revision of this document Information pertaining to this document is maintained on GPC GE Medical Systems Global Product Configuration If you need to know the latest revision contact the GE Ultrasound Clinical Answer Center at 1 800 682 5327 or 414 524 5698 1 for Applications 5 for Ultrasound GE Medical Systems GE Medical Systems Telex 3797371 P O Box 414 Milwaukee Wisconsin 53201 U S A Asia Pacific Latin America North America GE Ultraschall Tel 49 0 212 28 08 208 Deutschland GmbH amp Co KG Fax 49 0 212 28 02 28 BeethovenstraBe 239 Postfach 11 05 60 D 42665 Solingen GERMANY EZ USA Only CAUTION United States law restricts this device to sale or use by or on the order of a physician if sold in the United States CAUTION Read and understand the LOGIQ 700 Basic User Manual 2227866 100 and the Advanced Reference Manual 2227867 100 for operational details and safety concerns LOGIQ 700 Illustration Dire
25. ROI softkey dynamic range gray maps invert if preset and angle downward An ROI box is displayed on the image and CREATE appears on the SoftMenu in if preset The benefit of AUTO can be found in place of ROI reduced optimization time and a more consistent and 7 ur accurate optimization process Upon deactivation the 2 Position and size the AUTO ROI over the part of the image you want to use to optimize the spectrum is returned to the original map and dynamic image Size the ROI by adjusting the ROI Size rocker switch Position the ROI by moving the range however the velocity scale baseline and angle Trackball is still optimized You may find that you can skip this step and simply accept the default ROI position which In AUTO Spectral Doppler ask the patient to hold still uses the majority of the image data while activating AUTO You may need to reposition the 3 After you have positioned and sized the ROI click the AUTO CREATE softkey downward and cursor to remain within the vessel press Set B Mode Controls Direction 2227865 100 REV 0 Page 11 di E Refer To Image Optimize Chapter B Mode Controls Softkey Displays and Controls UP DOWN B LT RT 5 FR RES DYN RANGE 0 FRM 54 Previous CE FRAME SELECT Ac auger se UU oN R
26. ball to position the first cursor Press Caliper again 3 Trackball to position the second cursor Click Ellipse a Trackball to translate ellipse around fixed cursor Click Ellipse to size the ellipse Press Caliper to toggle between fixed and active cursor 4 Press Set to complete the Elipse measurement 5 Editing Measurements To erase the last part of the active trace press Backspace To remove an active caliper press Backspace To delete all measurements and annotations from the display but not from the worksheet press and hold down Shift and Delete All OB Exam Direction 2227865 100 REV 0 Page 21 Refer To General Measurements amp Calculations Starting an OB Exam To start an OB GYN exam v 1 Press New Pt 2 Type a Y to verify that this v is a new patient Press v Return 3 Trackball to select the OB GYN exam Press Set Type the following information press Return after each entry PATIENT NAME Patient s name Patient s identifying number Your initials Woman s date of birth Number of pregnancies Number of births Number of abortions Number of ectopic pregnancies Type LMP gestational age or estimated date of delivery Number of fetuses Patient s history Name of the referring physician Press EXIT Select application Type Y to enter past exam data for the fetus es OB GYN PT
27. ction 2227865 100 REV 0 Page 1 Refer To Getting Started Chapter ER Front View pP 1 Peripherals Peripherals are placed in front for Release 8 0 EXPERT and PRO Series or on top for Release 8 0 Update and 6 5 2 Gel Holders a Top of Control Panel Place the gel bottle here b Below Display Monitor Warm and store the gel bottle here 3 Speakers Stereo speakers are provided for audio Doppler VCR playback and error notification 4 Display Monitor System imaging monitor 5 Power Switch On Stand by switch 6 Probe Holders and Probes All imaging probes can be plugged into any of the probe ports Probes are automatically activated when the probe is lifted from its yoke or manually via Code S except for the 618e 739 I T 7 Control Panel All operator controls are located on the Control Panel 8 Handles and Raise Lower Button Use the handles to move the system Use the button to raise and lower the control panel Push and hold the button while moving the control panel up down 9 Optical Disk Optical disk and disk storage areas 10 Brake and Footrest The brake pedal and footrest the footrest is not available on all systems 11 Footswitch Use the footswitch to freeze an image or to send an image to the designated hard copy device LOGIQ 700 Illustration LOGIQ 700 Illustration LOGIQ 700 Illustration Direction 2227865 100 REV 0 Page 2 Refer To Getting Started
28. different user preset by clicking the DISPLAY 2D softkey Then select MANUAL 3D or one of the other user preset softkeys Manual3DView Perform a 2D scan of the anatomy Press Freeze RV MIN COLOR inverts image pixel intensities to gray scale Move Trackball Click BEGIN LOOP REVIEW MAX COLOR enhances bright Edit loop size using EDIT LEFT EDIT RIGHT softkeys Edit out extraneous frames using DELETE FRAME softkey Click Previous Next to access this SoftMenu Click 3D MODE softkey Use ROI Size to size and Trackball to position ROI Select the RECON METHOD for 3DView reconstruction HI RES for high resolution LO RES for low resolution SHEAR for quick reconstruction RESLICE quad cut plane rotate rotational cut plane and rotational cut plane modes Select SWEEP LENGTH that represents the actual sweep length or set to AUTO Click Previous Next Select VIEWS to be rendered 1 18 Set how to PROJECT the image MIN enhances dark objects in B Mode RV MIN inverts dark objects white background MAX enhances bright objects in B Mode AVG Averages white black objects SURFACE enhances anatomy s surface edges COLOR shows just color on black background MIN COLOR enhances dark objects of anatomy image in surrounding tissue while N Vertical showing the color in vessels 8 Specify around which AXIS to rotate the 3DView horizontal or vertical 9 Sel
29. e holder DO NOT apply excess gt force to probe head or to probe holder Follow recommended cleaning instructions after each use c Disconnecting I 1 Be sure that the probe head is clean before disconnecting the probe 2 Place the probe in its corresponding probe holder 3 Move the probe locking handle into the horizontal position 4 Pullthe probe and connector straight out of the probe port 5 Carefully slide the probe and connector away from the probe port and around the right side of the keyboard 6 Ensure the cable is free then store the probe in its carrying case Probes Peripheral Setup Presetting Print Keys VCR P To go to the preset menu 1 Press Code P To preset the peripheral devices 1 Press ROI Size until you reach Page 6 of 6 Press Set to select SNY SVO 9500 for Serial Port 1 2 Press Set to select SNY UP 18 2900 for Serial Port 3 Sony 1800 2900 printer To specify print keys P1 2 or Shift P1 2 1 Press ROI Size to the left until you reach Page 5 of 6 2 Specify the print key and color Trackball to the appropriate print key under COLOR or GRAY then press Set to place an asterisk to select 3 Specify archive print parameters by placing an asterisk under the appropriate print key next to HARD D
30. ect RANGE 0 90 45 45 0 180 or 90 90 10 Click Previous Next Specify whether you want the B Mode image displayed in the background of the 3DView via 3D BACKGND Specify the direction VIEW Specify the rotational resolution ROTATE RES 11 Click RENDER 3D softkey This generates the 3DView Rendered image __ of displays while the 3DView is being created To adjust the criteria used to create the 3DView 1 Click the CANCEL 3D softkey Change the criteria then click the RENDER 3D softkey again DO NOT turn the system off and back on while cancelling a 3DView The 3DView starts at 1 3 the speed and may be adjusted No measurements are allowed on the 3D View To return to 2D imaging Click DISPLAY 2D 3DView Hints Direction 2227865 100 REV 0 Page 27 Abdomen and Renal 3DView Recommended Settings Renal Mass PROJECT 3DView Hints D Refer To Image Optimize Chapter SWEEP LENGTH Renal Vascularity MAX COLOR Breast 3DView Recommended Settings Breast Tissue PROJECT MIN SWEEP LENGTH 0 5 2 5cm Hydro nephrosis Ductal System MIN 0 5 1 0cm Liver Mass Breast Mass Cystic Type MIN 0 5 4 0cm Hepatic Portal Veins Breast Mass Solid Type MIN MAX 0 5 4 0cm Liver Vascularity MAX COL COL MIN The numbered notes below apply to the number of the exam in the table Aorta above 1 2
31. ese as your default calculations by clicking the SAVE AS DEFAULT softkey Verify or cancel your selection by clicking SAVE YES NO To return to the exam click the ASSIGN VESSEL softkey SELECT TRACE on the Auto Vascular Calcs SoftMenu lets you indicate whether cardiac cycle detection and therefore cardiac cycle identification should use peak timeline data above below or above and below composite the baseline Auto Vascular Calcs Exam To select a different cardiac cycle press Freeze Press Caliper You must select the start or peak caliper to select a different cycle Use the Trackball to move to the desired cardiac cycle Press Set You need a couple of good cycles in front ot the new cardiac cycle for this to be successful Oftentimes this is problematic near a freeze bar Or you can move through CINE memory with the Trackball until the desired cardiac cycle is selected by the system To edit a caliper identifier press Freeze Press Caliper To move to the next crosshair identifier press Caliper again Reposition the identifier using the Trackball Press Set Use the Caliper key to cycle through identifiers Use the Trackball to move the active identifier Use the Trace key to retrace the cycle Press Set to complete the edit To assign the selected auto vascular calcs to a vessel click Previous Next until you reach the SoftMenu with the desired vessel Click the system user vessel softkey The system vessel is transferred to the works
32. fteen 10 15 seconds before switching system back on after power down and do not turn off the system immediately after turning it on Control Panel Layout Direction 2227865 100 REV 0 Page 5 Refer To Getting Started Chapter a Control Panel D 1 SoftMenu plus SoftMenu controls WARNING 2 Acoustic Output Optimizes image quality and allows user to reduce beam intensity Read descriptions for each control you intend to use before adjusting Acoustic Output or any control that affects Acoustic Output Use the minimum output to get the best diagnostic image or measurement during an exam Values greater than 0 1 are displayed Mechanical effects cavitation on biological tissue produced by acoustic beam Thermal effects on soft tissue Thermal effects on tissue with ossified bone near the focal point of the beam Thermal effects on bone located near the surface such as the cranium 3 Code Key Pressing this key plus a letter activates system features 4 DICOM End Exam Sends DICOM jobs at end of DICOM exam 5 Online Help Press Code H for online help 6 Auto Optimize Optimizes the image in B Mode Color Flow Mode and Doppler Mode 7 Zoom Magnifies the image 8 Set Fixes cursors accesses exits tasks and cycles through menu selections 9 ROI Size Sizes the region of interest views recalled archive or CINE images one image at a time pages through a
33. ftkey 3 Verify the delete command by clicking DELETE YES or cancel delete command by clicking DELETE NO Formatting an MOD 1 Insert the MOD 2 Press Archive Menu The Archive Menu and SoftMenu appear 3 Click ARCHIVE FORMAT softkey 4 Verify format by clicking FORMAT YES To eject an MOD press Archive Menu The Archive Menu SoftMenu appears Click EJECT MOD softkey Archive Refer To Recording Images mC Recalling an Image Archive Menu To recall an image 1 Press Archive Menu The Archive Menu with a list of currently stored images and the Archive SoftMenu appear 2 Trackball to highlight the image to be viewed Press Set to tag the image An asterisk appears next to the patient s name 3 Trackball to RECALL IMAGE and press Set The image appears on the screen You can perform measurements calculations unless the archive does not match the current patient s and annotations on an archived image To view multiple recalled images via slide show no measurements can be performed 1 Trackball to highlight the image to be viewed Press Set to tag the image Repeat until you have tagged all the images you wish to view 2 Trackball to RECALL IMAGE and press Set 3 Press ROI Size left right to view the recalled images To return to scanning press Freeze How to Use 3DView 3DView Direction 2227865 100 REV 0 Page 2
34. ght To stop 1 Press Play Stop To begin videotape playback 1 Press Play Stop again Playback gt gt v Play Record Stop Pause v Play Record Stop Pause v Play Record Stop Pause To playback an image 1 Press Play Stop To pause playback 1 Press Record Pause or Freeze To begin playback again 1 Press Record Pause or Freeze To stop playback 1 Press Play Stop VCR Recording Refer To Recording Images Chapter To search backward forward v during VCR playback Stop Pause 1 Click REV FF left right Hold the key in place while the VCR is searching Search Playback begins when you release REV FF Slow Search 1 Press Play Stop 2 Press Record Pause 3 Click and hold down REV FF left right 4 Press Record Pause to resume playback VCR Counter lt gt Code D The VCR Counter displays in the upper left hand corner as Hour Minute Second 0 07 00 To reset the VCR Counter 1 Press Code T You must have a cassette in the VCR GE Medical Systems GE Medical Systems Telex 3797371 PO Box 414 Milwaukee Wisconsin 53201 U S A Asia Pacific Latin America North America GE Ultraschall Tel 49 0 212 28 08 208 Deutschland GmbH amp Co KG Fax 49 0 212 28 02 28 BeethovenstraBe 239 Postfach 11 05 60 D 42665 Solingen GERMANY
35. heet Archive Direction 2227865 100 REV 0 Page 25 Queuing an Image to Print Archiving an Image To record image s onto the hard disk or MOD 1 Press Freeze 2 Press Home or Set Home to label the archived image Type the text to identify this patient s archived image up to seven 7 characters 3 Press P1 2 or SP1 2 to archive the image The system momentarily transfers the current image to the hard disk or MOD Copying Image To copy image s between the hard disk and M 1 Trackball to highlight the image to be copied Press Set to select the image 2 Trackball to the COPY IMAGES box Press Set Images being copied are prefixed by a negative sign DO NOT turn off the system while the system is copying or deleting archive images Depending on the number of images this could take up to six minutes Images on the MOD are prefixed by a plus sign To queue an image to print from the MOD to the DEFF print queue device 1 Trackball to highlight the image to be queued for print Press Set An asterisk appears in front of the tagged image 2 Trackball to the PRINT QUEUE box 3 Press Set A p appears in the SZ column to indicate this image is queued to print Deleting an Image To delete an image s 1 Trackball to highlight the image to be deleted Press Set An asterisk appears 2 Click DELETE IMAGES so
36. ical Images N To activate Multi Image 1 Press Multi Image 2 Press Code Z and click SIMUL softkey to ON 3 Press CF to activate color flow Most controls affect both images except CF and color flow controls BE gt ey BEGIN LOOP REVIEW LOOP SPEED 1 1 EDIT LEFT EDIT RIGHT EDIT LEFT EDIT CINE SYNC MODE LOOP Multi Image Refer To Getting Started Chapter C Multiple CINE Loops 34 To create multiple CINE Loops Set Code Z to OFF Press Freeze Move the Trackball Click BEGIN LOOP REVIEW Press Image Select Move the Trackball Click BEGIN LOOP REVIEW Ogre o Iw Aligning CINE Loops Aligning ps To align multiple CINE Loops 1 Click SYNC MODE to select type of synchronization LOOP START Aligns both loops to start at same time Shorter loop stops until longer loop ready to start again LOOP ALIGN Aligns both loops to start and end at same time C CINE Store DZ To store a CINE Loop click CINE STORE Color Flow PDI Mode Controls Color Flow PDI Controls Direction 2227865 100 REV 0 Page 16 Refer To Image Optimize Chapter Color Flow PDI Controls
37. n 2 Click desired body pattern softkey 3 Trackball to position probe marker Click Angle Correct to rotate probe marker 4 Press Set To deactivate press Body Pattern C Library d Stores 23 annotation scripts Code 1 Press Code L v 2 Type the code up to 4 O characters Trackball to TEXT column v 3 Type the script Press Aorta Return 4 Press Exit when you Exit are done _ Using Library Scripts Recalls script to the display Pa 1 Type the code 2 Press Set Multi Image Direction 2227865 100 REV 0 Page 15 dii 1 Use Multi Image with Code Z Off to e View anatomy larger than the probe s field of view or footprint Get 2 shots on one photo Compare 2 different scan planes Different Images To activate Multi Image 1 Press Multi Image Any control changes only affects the live image To select the other image 1 Press Image Select Control settings transfer to newly selected image one CINE DEE You can create identical Code Z On or different Code Z Off CINE loops Freeze v To activate CINE Multi Image press Freeze Move the Trackball To activate CINE Loop click BEGIN LOOP REVIEW 3DView is not available in Multi Image C _ Use Multi Image with Code Z On to Get 2 live images e Apply color Ident
38. rts and vice versa Vascular Exam To start a vascular exam Pt 1 Press New Pt T 2 Type a Y to verify that this Return is a new patient Press Return 3 Trackball to select the vascular exam Press Set v VASCULAR Auto Vascular Auto Vascular Calcs enable the LOGIQ 700 to detect and identify a cardiac cycle and allows the user to assign measurements and calculations during live timeline imaging or while the image is frozen or in CINE Peak values are detected for venous flow A Volume Flow measurement is also available to measure the rate of flow of a vessel in units of ml min Auto Vascular Calcs Presets To activate Auto Vascular Calcs press Spect Trace Code Q Click the AUTO VASC CALCS softkey to LIVE or FROZEN To set up vessel names on the application Vessels Setup menus press Spect Trace Code Q Click SPECIFY VESSEL NAMES The application s Vessels Setup Menu appears Trackball to the first available space and type the vessel Press Exit The vessel s now appear on the exam s SoftMenu The assigned calculations to this vessel display but do not appear on the report pages To select the calculations to be displayed in a continuously scrolling window in Auto Vascular Calcs press Freeze Click Previous Next until you reach SELECT VASC CALC Select the calculations you want to display by clicking the calculation s softkey Save th
39. series of menu pages and cycles through body patterns 10 Trackball Multiple uses 11 Freeze Freezes unfreezes the image Angle Correct Doppler Gain Auto Angle Push Down aw Update Control Panel Layout Adjusting the Monitor Monitor Adjustments Direction 2227865 100 REV 0 Page 6 Refer To Getting Started Chapter Qv Be e To cs 2 1098053 4 Brightness ALC On Off Contrast Degaussing Control Ambient Light Control Sensor Adjusting the Monitor Top Vi j i op View To adjust the Brightness EN Press Code Click the VIDEO TEST PATTERN softkey Images are recalled in rs a few moments Press ROI Size until the following test pattern appears Turn the brightness knob to the left or right until monitor s background black matches the black in the upper left hand rectangle of the test pattern This is probably not the detent position To adjust the Contrast Turn the contrast knob to the left or right Increase the Contrast to display the complete or desired range of gray shades Press Freeze to return to scanning Do not change the controls once they have been set Once set the display then becomes the reference for the hard copy device s m can tilt the monitor up and down and pivot the monitor 85 to the left and right Probes Direction 2227865 100 REV 0 Page 7
40. t right lt FE Invert Flips Doppler spectrum inverts color flow Press Invert 4 Velocity Scale Adjusts velocity scale to accommodate faster slower blood flow velocities To increase decrease click up down 10 SV Gate Size amp Position Controls Doppler sample area size Sample Volume Gate Position Trackball left right to position Mode Cursor Trackball up down to position over vessel Sample Volume Gate Size Click up to increase down to decrease M Mode Controls Direction 2227865 100 REV 0 Page 19 Refer To Image Optimize Chapter MMode Controls _ 1 Softkey Displays and Controls M DYN RANGE 60 SWEEP VIDEO UP DOWN M ED LT RT ENHCE 0 SPEED INVERT Code MEDIUM OFF UP DOWN WALL COLOR SWEEP 52 0 Color LT RT ow cm s V 0 MEDIUM PACKET FILTER FRAME COLOR SIZE MODE AVG THRES Next 10 ACE OFF 66 Hm gt COLOR COLOR COLOR TAG TAG SIZE POS Code A o es um Color Flow Update OAR COO 0 ND M Mode Controls Basic Measurements Distance amp Circumference
41. the Shift and Delete All keys To move comment cursor to home position press Home To specify a new home position 1 Press Comment 2 Trackball to where you want the new home position to be 3 Press and hold down the Shift and Set Home keys Delete All Measurements and calculations Backspace are also deleted from the display International Characters To type an international character 1 Press the Option key marked on the keyboard as a triangle plus a combination of keystrokes shown below 6 A n aon 1 6 0 e a i 0 u 5 0 i 6 8 6 1 0 U 6 1 0 0 N a i 0 u METTE A a A 0 Qe D sebo A 5 c Gl sates A G D P Russian A Greek A Exit Arrow keys Delete All Backspace Word Tab Word Delete a ard BEE Comment Library Code L Return key Option key A Body Pattern 0 Comment key CRISE Set Home Home Refer To Getting Started Chapter c Adds body pattern to the display Body Patterns To activate 1 Press Body Patter
42. u use the specified authors calculations Hadlock Merz Jeanty Williams or Brenner Data for these graphs is taken from the current exam as well as from the data entered on the PAST EXAM DATA 1 2 menus To view OB Graphs 1 Click the REPORTS softkey click the GRAPHS softkey then click the softkey corresponding to the report you want to view Click Previous Next to move to the ratio OB graphs To move to the next fetus s data press ROI Size 2 If required type a new age gestational age in the EDIT GA field The OB GRAPH plots current and previous exam calculation measurements on the growth curve and gives a growth percentile GP The fetus s age in weeks is charted along the x axis the calculation s measurement in cm or g is charted along the y axis Vascular Exam Vascular Exam Direction 2227865 100 REV 0 Page 24 Refer To General Measurements amp Calculations Vascular Exam Presets To select Stenosis preset 1 Press Code P Page 1 of 6 2 Trackball to Stenosis Method Select Area or Diameter 3 Trackball to RI Calc Method Auto Select PS or ED Manual Vascular Manual Vascular Calcs require you to manually take measurements which will be assigned to the Manual Carotid Summary Report Calculations assigned to the Manual Carotid Summary Report do not appear on the Auto Vascular Calcs Carotid Summary Repo
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 [ DESCRIPTION ] RV Products 8534 SERIES Product data Tripp Lite OmniSmart UPS System 2558A AC Voltage Current Standard User`s Manual Leveraging eXist-db for Efficient TEI Document micro EXPLORER Siemens LD97AA670B cooker hood Epson 1080p Service Manual EPSON CP-920Z ユーザーズガイド Copyright © All rights reserved.
Failed to retrieve file