Integration Document for the Promass 100

image

Contents

1. 1 Depending on the housing version loosen the securing clamp or fixing screw of the housing cover and then unscrew or open the housing cover 2 Set the desired IP address using the corresponding DIP switches on the I O electronics module Hardware addressing with the configured IP address ts enabled after 10 seconds 3 Reassemble the transmitter by reversing the removal procedure Software Addressing Software addressing is carried out in the Communication submenu using the navigation path Setup gt Communication in the Web Server When delivered the measuring device has the following factory settings 192 168 1 212 295 299 299 0 192 168 1 212 IP address Subnet mask Default gateway IMPORTANT e If hardware addressing is activated software addressing is disabled If a switch is changed to the ON position then the first three octets of the software address are retained f the IP address of the device is not known the device address currently configured can be read by activating dip switch No 10 restarting the device and logging on to the Web server E H Publication SP00031A 04 en 01 12 RA Publication PROCESS AP060A EN P September 14 Promass 100 Flowmeter via EtherNet IP into the PlantPAxProcess Automation System Install the E H Promass 100 AddOn Profile AOP An AOP is a way to bring a definition of a new Allen Bradley device or devices from our Encompass partners into RSLogix 5000
2. W Use Unicast Connection over EtherNetlP Module Fault Status Creating OF Cancel Help E H Publication SP00031A 04 en 01 12 RA Publication PROCESS AP060A EN P September 20 Promass 100 Flowmeter via EtherNet IP into thePlantPAxProcess Automation System e In the Module Info screen you can view the device information E New Module l xj General Connection Module Info Intemet Protocol Fort Configuration Medium Selection System Units Supervision Tota_4 r Identification Status Vendor Endress Hauser Major Fault Product Type Generic Device keyable Minor Fault Product Code Promass_ 100 Revision 1 1 Seral Humber 00100025 Configured Configured Product Name Fromass 100 Owned No Module Identity Match Refresh Reset Module e Status Creating Cancel Help e In the Internet Protocol screen you can set up the Internet protocol E Module Properties EtherNet_IP_Interface Promass_100 1 1 General Connection Module Info Internet Protocol Port Configuration Medium Selection System Units Supervision Tota_4 r Internet Protocol IF Settings IP settings can be manually configured or can be automatically configured if the network supports this capability Manually configure IP settings IP Settings Configuration Physical Module IP Address 132 1765 1 180 Subnet Mask 255 255 255 0 Gateway Address 192 168 1 213 Doma
3. These profiles will vary depending on the manufacturing and function of the target device All contain some configuration and automatic tag creation so you do not have to figure out how data is mapped or spend time creating aliases to point at the generic tags This section describes how to install an AOP from Endress Hauser for a Promass 100 Mass Flowmeter Note The AOP is preinstalled in RSLogix 5000 versions 21 and higher 1 Download the Promass 100 AOP from htto Awww products endress com ethernet ip eds 2 Double click the MPSetup exe file from the download location The setup screen is displayed iz RSLogix 5000 Module Profiles Setup o amp amp Welcome to the RSLogix 5000 Module Profiles Setup Wizard The RSLogix 5000 Module Profiles Setup Wizard provides for installation of these groups of RSLogix 5000 Module Profiles Endress Hauser EtherNet IP Comm Module Profiles 1 18 1 Details Net gt Canca 3 Click Next and on subsequent screens continue to follow the prompts accepting the default selections and clicking Next 4 When a screen saying that the setup is complete is displayed click Finish The AOP is installed and available to add to the RSLogix 5000 Project as described in the following section RA Publication PROCESS AP060A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 15 Load
4. BE a i F DESCHP TEIH RSSa eee Click on Global w W Object whe oss Eo 4 q E J E L g LiL 10 aeaa wo Bo IMPORTANT A unique global object and faceplate are available for each field instrument due to each instrument having specific extended diagnostics E H Publication SP00031A 04 en 01 12 RA Publication PROCESS APO60A EN P September 30 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System Faceplates The FactoryTalk View SE generic display provides a graphical representation of the instrument based on the information contained within each Add On Instruction Navigation buttons at the top of the faceplate change the information displayed Status displays show information using a bar graph numeric values and trend displays Other displays show specific alarms and warning indications Some examples of predesigned faceplates are shown below DESCRIPTION DESCRIPTION DESCRIPTION Ee SAFES OS Hee Totalizer 1 z 7 eats l amp la 2 Mass Flow Totalizer 2 A Threshold Deadband Delay sec Ib min lb min On Off Totalizer3 a High High 1 50638 100 oO TAGNAME Mass Flow 0 0 High 1 50E38 1 00 Mass Flow Trend Scaling Max 100000 0 100000 0 hin 0 00 0 00 Mass Flow 129 92 b min Volume Flow 0 02 US Mgal d Corr Vol Flow 3 59 mh Fail High 103 96 Density 1 00 g cc Fail Low 2 06 Ref Density 1 00 g Scc Temperature 74 45 D
5. Control System 1756 L63 For further details see the PlantPAx Process Automation System Selection Guide publication PROCES SG001 EN P Software Components Component Catalog Number RSLogix 5000 Enterprise Series 9324 RLD700NXENE programming software Professional edition Includes e RSLinx Classic software RSLinx Enterprise software Factory Talk View Site Edition SE software 9701 VWSXXXXXENE optional Factory Talk AssetCentre server optional 9515 ASTSRVRENE Factory Talk AssetCentre process device 9515 ASTPRDCFENE configuration optional E H FieldCare Standard Asset Management SFE500 software optional For additional information on drivers see Additional Resources on page 34 For specifications of the engineering workstation EWS and operator workstation OWS see the PlantPAx Process Automation System Reference Manual publication PROCES RMO001 RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 9 Installation The information in this section provides a summary of the installation procedures IMPORTANT For complete installation instructions including warnings see Additional Resources on page 34 Installation can be accomplished by utilizing fieldbus connectors The method is described below Transmitter EtherNet iP connection version i Order code for P
6. Engineered System perp aan Solutions Process olutions Networks Platforms Complete process automation projects Integrated Architecture Fieldbus Device profiles Asset management System integration MES information Device configuration Batch Rockwell Automation competence To reduce the risks associated with integrating many devices from many different suppliers Rockwell Automation pretests many third party manufactured HART FOUNDATION Fieldbus EtherNet IP and PROFIBUS PA field devices in the system test laboratory for compatibility with the Rockwell Automation PlantPAx automation system Each field device is connected to the PlantPAx system and is subjected to interoperability testing procedures similar to operating procedures in your plant The results of each field test are recorded in a test report for integration planning purposes For Endress Hauser field devices an additional step provides an Integration Document and Interoperability Statement for each tested instrument The Integration Document provides information on installation configuration startup and operation of the integrated system The Interoperability Statement is assurance that the Endress Hauser field device meets PlantPAx system interoperability performance measutes as jointly established by Rockwell Automation and Endress Hauser and verified through completion of common test procedures performed by either company Both the Integra
7. EtherNet IP into thePlantPAxProcess Automation System Appendix Configure via Configuring the Internet Protocol of the Computer Web Server The device has the following default EtherNet settings Note The factory setting for the device IP address is 192 168 1 212 IP address 192 168 1 XXX for XXX all numerical values except 0 212 and 255 Example 192 168 1 213 Subnet mask 255 259 255 0 Default gateway 192 168 1 212 1 Switch on the measuring device and connect it to the computer using the cable 2 Configure the properties of the Internet protocol TCP IP as defined in the table above Starting the Web Server 1 Start the Web Server on the computer 2 Ifthe IP address of the measuring device is known enter the defined device address in the address line of the Web browser The login screen is displayed Device tag EH Endress Hauser Webserv language English v Ent access code iiai OK Access stat tool Maintenance AL ee I Device fag 2 Picture of device RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 33 Disabling the Web Server The Web server of the measuring device can be switched on and off as required using the Web server functionality parameter Navigation path Menu tab gt Expert menu gt Communication gt Web
8. ioj x General Connection Module Info Internet Protocol Fort Configuration Medium Selection system Units Supervision Tota 4 Flaw Mass Flow kah Mass Unit kg Volume Flow m3h Volume Unit ma Cor Volume Flow Mmh Cor volume Unit Mma Density Density Reference Density kg Ml zi Others Pressure bar 4 Temperature e Celsius Status Running Cancel Apply Help e In the Supervision screen you can configure the diagnostic behavior and Write Protection parameters E Module Properties EtherNet_IP_Interface Promass 100 1 1 General Connection Module Into Internet Protocal Part Configuration Medium Selection System Units Supervision Tota Write Protection Ott v Assign behavior of diagnostic Alarm Delay OO 5 832 Ambient Temperature warning O44 Sensor Drift Warming 623 Ambient Temperature Waning T O46 Sensor Limit Warming 834 Process Temperature Waning 192 132 Evert 9 Waning gt 635 Process Temperature Waming gt 24 Main Electronic Warming 912 Inhomogenesous wami 392 Event 10 Waming 913 Inhomogenesous wami 592 532 Event 11 Wwaming gt 992 932 Event 12 warming gt Status Running Cancel Apply Help RA Publication PROCESS AP060A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automati
9. server gt Web server functionality Parameter oe ae Factory Settings Web Server functionality Switch the Web e Off On server on and off e On Enabling the Web Server If the Web server is disabled it can only be re enabled with the Web server functionality parameter via the following operating options FieldCare operating tool RA Publication PROCESS AP060A EN P September 34 Promass 100 Flowmeter via EtherNet IP to the PlantPAx Process Automation System Additional Resources Resource EtherNet IP Field Instruments Proline Promass 100 Technical Information publication T101034DEN Proline Promass 100 Operating Instructions Proline Promass EtherNet P publication BA01065DEN htto www products endress com ethernet ip eds htto www products endress com flow Control System Components ControlLogix Controllers Installation Instructions publication 1756 IN101 ControlLogix Controllers User Manual publication 1756 UM001 ControlLogix Ethernet IP Modules 1756 IN612B EN P Operator Components Factory Talk View Site Edition User s Guide publication VIEWSE UM006 Faceplates Add On Instructions project files etc htto rockwellautomation com knowledge base Login required Please contact your sales representative Process Control Information Integrated Architecture for Process Control System Recommendations Manual publication PROCES RM001 http www rockwellautomation com process http literatur
10. the Electronic Data Sheet EDS File Although the EDS file for this device is typically included in the installation of the AOP it is also available for you to install separately If necessary you can access it from the device through RSLinx or the Web Server or the manufacturet s website If you want to access the EDS file from Then the device through RSLinx 1 Go to RSLinx Communication and open the Network view under RSWho 2 Right click on the device and select Upload EDS File from device the device through the Web Server 1 Go to the Network Configuration screen Click the button Load EDS File Nh htto Awww products endress com eth 1 Download the EDS file ernet ip eds save the file to your desktop Double click the file and follow the on screen prompts oo PO IMPORTANT Use the RSLinx EDS Hardware Installation Tool to install the EDS file E H Publication SP00031A 04 en 01 12 RA Publication PROCESS AP060A EN P September 16 Promass 100 Flowmeter via EtherNet IP into the PlantPAxProcess Automation System Configure the E H There are several options to configure the I O in the Add On Profile Promass 1 00 Flowmeter AOP The option Device Configuration via the AOP described in the i procedure below is used as an example with the AOP In the RSLogix 5000 project ensure that the Ethernet Module s and communication settings are established before installing the Promass 100 For assistance
11. with setting up Ethernet communications via the ControlLogix Platform refer to www rockwell com or ask the local Rockwell Automation distributor Establish the Configuration of the E H AOP 1 On the left side of the RSLogix 5000 project screen right click the Ethernet Module and then select New Module SS 10 Configuration Backplane 1789 4174 Virtual Chassis Aa 1 1769 L60 E_H_EIP_Promass 3 E i 2 EtherWet IP MY MG gt Ethernet r New Module A Cut Erle Copy Ctrl C Description This i the MIC of Sot Delete Del Status Offline Module Faut Cross Reference Ctril E Properties Alt Enter Print 2 Click the Catalog tab select Promass_100 and then click OK Catalog Module Discovery Favorites pro Clear Filters Show Filters y Catalog Number D Categor Promag_53 EtherNet IP Electromagnetic Flow Meter Endress Hauser Specialty Promass_100 EtherNet IP Mass Flow Meter Endress Hauser Specialty Promass_83 EtherNet IP Mass Flow Meter Endress Hauser Specialty Ef 3 of 199 Module Types Found Add to Favorites IV Close on Create Close Help M RA Publication PROCESS AP060A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 17 E H Publication SP00031A 04 en 01 12 Do not click OK in the Module Properties screen until you have IMPORTANT IMPORTANT completed defining the modul
12. 0 1 1 Process Parameters Calculated Value External Compensation Low Flow Cut Off Partially Filled Pipe Detection Sensor Adjust_4 EFE Density hd Response Time 10 g Mas Damping 0 000 Value Low 0 0 kgl Value High 0D kgl oe Status Anning Cancel Apply Help RA Publication PROCESS APO60A EN P September 26 Promass 100 Flowmeter via EtherNet IP into thePlantPAxProcess Automation System e Inthe Sensor Adjustment screen you can configure the sensor flow direction E Module Properties EtherNet_IP_Interface Promass_100 1 1 Calculated Value External Compensation Low Flow Cut or Partially Filled Fipe Detection Sensor Adjustment Custom Input CA Installed Directiory Flow in arrow direction Status Running Cancel Apply Help e Inthe Custom Input Connection screen you can configure the Custom Input connection E Module Properties EtherNet_IP_Interface Promass_100 1 1 Low Flow Cut Off Partially Filled Pipe Detection Gensor Adjustment Custom Input Connection Vendor Custom Input Assembly Pasition 1 Mass flow Pesin a Mass flow unit Pasition 2 Volume flows Pedin iz Volume flow unit Position 3 Corrected volume Flaw Brelima Corrected volume flow unit Position 4 Temperature Position 14 Temperature unit Position 5 Density Pasitinn 15 Density unit Position 6 Reference density Position 16 Reference de
13. 100 This integration document assumes you have a working knowledge of ControlLogix systems For more details regarding the equipment and tasks described in this document see Additional Resources on page 38 RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 5 Promass Flowmeter Promass measuring instruments make it possible to simultaneously record several process variables mass density temperature for various process conditions during measuring operation Promass sensors tried and tested in over 100 000 applications offer the following e Multivariable flow measurement in compact design e Insensitivity to vibrations thanks to balanced two tube measuring system e Immunity from external piping forces due to robust design e Easy installation without taking inlet and outlet runs into consideration The measuring principle is based on the controlled generation of Coriolis forces In the sensor two parallel measuring tubes containing flowing fluid oscillate in antiphase acting like a tuning fork The Coriolis forces produced at the measuring tubes cause a phase shift in the tube oscillations At zero flow when the fluid is at a standstill the two tubes oscillate in phase 1 Mass flow causes deceleration of the oscillation at the inlet of the tubes 2 and acceleration at the outlet 3 The phase differe
14. However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor in order to complete the return process Outside United States Please contact your local Rockwell Automation representative for the return procedure Allen Bradley ControlLogix FactoryTalk Rockwell Automation RSLinx RSLogix 5000 and TechConnect are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Endress Hauser is trusted by more than 100 000 customers to make their Rockwell Automation Inc NYSE ROK is a leading global provider of industrial processes safe efficient and environmentally friendly We offer a range of automation power control and information solutions that help manufacturers achieve a measurement products including level flow pressure temperature analytical competitive advantage in their businesses The company brings together leading global and complete engineered solutions designed to help customers acquire brands in industrial automation which include Allen Bradley controls and services and transmit control and record process information needed to manage operations Rockwell Software factory management software in a safe reliable and profitable manner s www rockwellautomation com solutions p
15. PlantPAx Process Automation System Endress Hauser 21 People for Process Automation Integration Document Promass 100 Flowmeter via EtherNet IP to the PlantPAx Process Automation System ka mi _ T of ligi Topic Preferred Integration Application Overview Example System Installation Configure the E H Promass 100 Flowmeter with the AOP Visualization Using AOls and Faceplates Appendix Configure via Web Server Additional Resources Allen Bradley Rockwell Software Page oO CO gt 28 32 34 Rockwell Automation 2 Promass 100 Flowmeter via EtherNet IP into thePlantPAxProcess Automation System Preferred Integration Endress Hauser competence Instruments m D gt Process instruments and applications for all industries RA Publication PROCESS APO60A EN P September 2012 29920 nia Sm STS Rockwell Automation and Endress Hauser have strengthened their strategic alliance to provide complete process automation solutions that use best in class instrumentation software and control systems There are hundreds of different components in a typical plant controllers remote I O electrical drives safety equipment and sensors Each must be integrated configured and optimized during start up and operation Recognizing the challenges this creates Rockwell Automation and Endress Hauser are focused on providing scalable off the shelf solutions
16. To monitor the instruments using the predesigned faceplates the EtherNet IP must be set up as specified in this integration document and the manual The controller exchanges data between the devices and the FactoryTalk View SE faceplates notify personnel what is happening in the plant The following information allows you to customize the Promass 100 and set up the function blocks to use the Add On Instructions AOD with an HMI server See Additional Resources on page 34 for more detailed information Add On Instructions An Add On Instruction exchanges data between each process variable located in the process device and the faceplate installed on a display The name of the specific instance of the Add On Instruction becomes the link from the actual instrument to the faceplate on the graphic RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 29 Global Object A global object links the tag name to the faceplate provides a touch area for the faceplate to be launched from and displays the process variables and alarms FactoryTalk View SE Display Add On Instructions imepania Cacteey Talk View SC Cleat in a Function Block ee Endress Hauser Instruments Version 1 00 ia a gg yh hs Wl a i ee F ai PA Fis hang Hind oe A rica a 1 i a A ali 1 Saiid 8 j
17. ction Types Fixed Wo Custom Input Only Pieced Wo Custom Input Only Revision Fixed Input Only Custom Input Only Cancel Help c For more information about the available connections in the AOP refer to the table below Yes or No Fixed I O Custom Input Only Fixed Input Only Custom Input Only If using the AOP for device configuration Config Assembly Yes the configuration in the device is overwritten with every Forward Open command If you choose Config Assembly No then you have to use the Web Server ot FieldCare to configure the device E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 19 IMPORTANT Do not click OK in the Module Properties screen until you ensure that the module properties have the settings that you prefer 5 If preferred you can customize the Endress Hauser Promass 100 AOP properties using the tabs at the top of the Module Properties screen e In the Connection screen you can set the Requested Packet Interval RPI and other communication parameters E Module Properties EtherNet_IP_Interface Promass_100 1 1 7 Ioj x General Connection Module Info Internet Protocol Fort Configuration Medium Selection System Units Supervision Totaal Requested Packet Interval AFI 100 0 me 50 0 9999 9 Inhibit Module Major Fault On Controller If Connection Fails While in Run Mode
18. e as described in steps 3 through 5 3 In the Module Properties screen a Enter the necessary information in the Name and Ethernet Address fields b In the Module Definition section click Change BS Module Properties EtherNet_IP_Interface Promass_100 1 1 ioj x General Connection Module Info Internet Protocol Fort Configuration Medium Selection System Units Supervision Tot 4 Type Promass_ 100 EtherWetlP Mass Flow Meter Vendor Endress Hauser Farent EtherNet_IP_Interface Ethernet Address Name Promass_1 n Private Network 192 168 1 Description it IF Address 1952 168 1 223 E Host Name Module Definitiori Serez A Change Revision 1 1 Electronic Keying Compatible Module Contig Assembly Yes gt Number of Connections 1 A Defaut Contig Units USWA Status Creating OF Cancel Help RA Publication PROCESS AP060A EN P September 18 Promass 100 Flowmeter via EtherNet IP into the PlantPAxProcess Automation System Config Assembly Number of Connections Connections Types RA Publication PROCESS APO60A EN P September 2012 4 In the Module Definition screen a Click the Connection Type s drop down list and select Fixed I O Custom Input Only b Click OK x Series la fi Electronic Keping Compatible Module Config Assembly Number of Connections Default Config Units Conne
19. e rockwellautomation com http www endress com http www endress com rockwell RA Publication PROCESS APO60A EN P September 2012 Description specifications and details of the Promass 100E flowmeter How to install wire configure and operate a Promass 100 flowmeter Download EDS and AOP files for field instrument Information about Endress Hauser flowmeters How to install and configure a ControlLogix controller How to configure operate and maintain a ControlLogix controller Installation Instructions ControlLogix EtherNet IP Communication Module How to design develop and deploy FactoryTalk View SE applications Download AOls Faceplates and Global Object graphics project files and documents Process system recommendations that organize Rockwell Automation products functionally as system elements which can then be applied in proven scalable configurations for continuous and batch control Information about Rockwell Automation process control and Integration Documents Available Rockwell Automation publications including Integration Documents Information about Endress Hauser Information about the partnership between Rockwell Automation and Endress Hauser and the Integration Documents E H Publication SP00031A 04 en 01 12 CerabarS Pressure Transmitter via PROFIBUS PA to the PlantPAx Process Automation System 35 Notes E H Publication RA Publication PROCES APOxxA EN P July 2012 Rockwell Auto
20. ection e g ControlLogix CompactLogix or PlantPAx from Rockwell Automation is possible Programming software PlantPAx is an easy object oriented explorer based drag and drop configuration that allows you to build complex process functions Furthermore the software allows you to mix and match IEC61131 3 compliant programming languages All supported programming languages share the same development environment tag database and user interface resulting in reduced training and higher productivity Visualization software Factory Talk View Site Edition software is an HMI software program for monitoring controlling and acquiring data from manufacturing operations throughout an enterprise A faceplate provides a graphical representation of the instrument through the Operator Work Station Faceplates associated with every instruction help you set up tune and control the element with a minimum of effort Additions and modifications can be performed online while your process keeps running E H Publication SP00031A 04 en 01 12 RA Publication PROCESS APO60A EN P September 8 Promass 100 Flowmeter via EtherNet IP into the PlantPAxProcess Automation System Example System Endress Hauser and Rockwell Automation interoperability testing is performed for every new device and product Hardware Components Component Catalog Number Promass 100 Coriolis Flowmeter 8F1B08 N EtherNet IP Communications Module 1756 EN2T ControlLogix
21. eg F Low S50E38 1 00 0 Low Low 1 50E38 1 00 0 42 SYSTEM OK f Bumpless Program Operator Transition DESCRIPTION DESCRIPTION DESCRIPTION t e Eae aaa en ele f eel Ack Reset Severity Alarm Reqd Reqd 1 2 3 4 f Device Fail Yi yf High High yf High yf Low Raw Input Scaling yf Low Low E nput Maximum 145 00 Alarm Minimum ON Time seconds aes 0 00 Device Fail High High High A J J rA Units b min Disallow selection of Substitute PV Low poet Jf Clear Program Commands on receipt PW Filter Time Constant sec 0 0 unfiltered RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 31 IMPORTANT A unique global object and faceplate are available for each field instrument due to the display of instrument specific extended diagnostic information The faceplates provide the following information from the device e Process values e PV fault status communication fault e Device extended status You can configure the faceplates to provide the following information e Tag name e Description e Engineering units e Mode such as operator or program e High high high low low low alarms e Over range and under range alarms e Alarm delay e Alarm hysteresis E H Publication SP00031A 04 en 01 12 RA Publication PROCESS APO60A EN P September 32 Promass 100 Flowmeter via
22. in Mame Host Hame Refresh communication Get E Status Running Cancel Apply Help RA Publication PROCESS AP060A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 21 e Inthe Port Configuration screen you can set up the port configuration Gi Module Properties EtherNet_IP_Interface Promass_100 1 1 Z joj x General Connection Module Info Internet Protocol Fort Configuration Medium Selection System Units Supervision Tota_4 r tit ao Sned reitos Negotiate Selected Selected Diagnostics I M es LS ea y d Refresh communication Gel e Status Running Cancel Apply Help e Inthe Medium Selection screen you can define the fluid being measured E Module Properties EtherNet_IP_Interface Promass_100 1 1 General Connection Module Info Internet Protocol Port Configuration Medium Selection System Units Supervision Tota_4 Medium Liquid Gas Type Alr Reference Sound elocity ss Temperature CoeffS ound Yelocity a Status Running Cancel Apply Help E H Publication SP00031A 04 en 01 12 RA Publication PROCESS AP060A EN P September 22 Promass 100 Flowmeter via EtherNet IP into thePlantPAxProcess Automation System e In the System Units screen you can configure the measuring units E Module Properties EtherNet_IP_Interface Promass_100 1 1
23. ltimately leads to faster troubleshooting and improves decision making PlantPAx Process Automation System E H Publication SP00031A 04 en 01 12 RA Publication PROCESS APO60A EN P September 4 Promass 100 Flowmeter via EtherNet IP into thePlantPAxProcess Automation System Application Overview This document provides a step by step approach to integrating an Endress Hauser Promass 100 Coriolis Mass Flow Measuring System into a Rockwell Automation PlantPAx process automation system via EtherNet IP This Section Describes Application overview Details about the field instrument and control system System details Specifications on the required hardware and software components Installation How to connect the measurement instrument to the EtherNet IP interface Configuration How to two separate sections e Configure the EtherNet IP interface Configure the measurement instrument Visualization How to implement and configure a graphical display of device information The ControlLogix platform provides a robust EtherNet IP backbone for communication to process fieldbus networks The PlantPAx system architecture uses producer consumer technology allowing input information and output status to be shared by all ControlLogix controllers in the system Engineering Work Station Operator Work Station EWS OWS Process 3 Automation System Server PASS EtherNet IP Stratix 8000 S EtherNet IP gt Promass
24. mation Support Rockwell Automation provides technical information on the Web to assist you in using its products ott rockwellautomation com you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit http support rockwellautomation com Endress Hauser Support Please refer to your local Endress Hauser Sales Center for precise information regarding the service support available in your area or visit http www endress com Installation Assistance If you experience a problem within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running United States 1 440 646 3434 Monday Friday 8 a m 5 p m EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility
25. nce A B increases with increasing mass flow Electrodynamic sensors register the tube oscillations at the inlet and outlet System balance is ensured by the antiphase oscillation of the two measuring tubes The measuring principle operates independently of temperature pressure viscosity conductivity and flow profile Measured Variables e Mass flow proportional to the phase difference between two sensors mounted on the measuring tube to register a phase shift in the oscillation e Volume flow calculated from mass flow and fluid density the density is proportional to the resonance frequency of the measuring tubes e Measuring tube temperature by temperature sensors for calculatory compensation of temperature effects e Density by monitoring the tube frequency is directly proportional to medium density e Totalized flow E H Publication SP00031A 04 en 01 12 RA Publication PROCESS AP060A EN P September 6 Promass 100 Flowmeter via EtherNet IP into the PlantPAxProcess Automation System Instrument Specifications e Communication Standard EtherNet IP up to 100 Mbps ODVA compliant IEEE 802 3 e Supply voltage 20 to 30 VDC e Ambient temperature 40 to 60 C 40 to 140 F e Degree of protection IP 66 67 NEMA 4X e Approvals CE marked for nonhazardous area application ATEX IECEx cCSAus e EMC IEC EN 61326 and NAMUR Recommendation NE21 e Device configuration Multiple options e Ethernet co
26. nnection Bus Plug 4 pole M12 connector per IEC 61076 2 10 e IP Addressing Configurable EtherNet IP and Web server addresses Hardware device addressing by DIP switches Software device addressing by integrated Web server DHCP or Static IP addressing supported e Status condition Four LEDs for communication status e Security Password protected with four definable levels e Data mapping 16 Autoscan registers for data transmission Preconfigured for easy integration but can be user defined Positions 1 to 10 for input value reporting Positions 11 to 16 for output control e Integrated Web server Operation supported in standard web browser e EDS file Embedded in the device for RSLogix 5000 integration e Add on profile Available for Promass 100 with EtherNet IP IMPORTANT The use of DLR requires Stratix 4000 EtherNet Tap RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 7 Control System The control system includes these components Component Description Controller The Logix controller is a modular high performance controller which uses RSLogix 5000 programming software to configure program and monitor a system EtherNet IP Communication The EtherNet IP Communication Module serves as a linking device bridge module seamless integration into control systems with direct EtherNet IP conn
27. nsity unit EAA Supervision exciter current 1 Fozition 17 Current Position 8 Totalizer 1 Position 18 Unit totalizer 1 Position 3 Totalizer 2 Position 19 Unit totalizer 2 Bretinn 10 Totalizer 3 Fozition 20 JUnit totalizer 3 Status Running Cancel Apply Help RA Publication PROCESS AP060A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 27 e In the Vendor screen you can view the vendor information E Module Properties EtherNet_IP Interface Promass 100 1 1 one re Rares eee nites www endres com Program Files FS Logs S000 Module Proties a E 6 When the module is defined according to your preferences in the Module Properties screen click OK 7 In the RSLogix 5000 warning screen click Yes to complete the Promass module setup will cause module data types and properties to change Data will be set to default values unless it can be recovered from the existing module properties Verify module properties before Applying changes Change module definition 8 Ensure that you save the RSLogix 5000 file first and then download the file to the ControlLogix controller E H Publication SP00031A 04 en 01 12 RA Publication PROCESS AP060A EN P September 28 Promass 100 Flowmeter via EtherNet IP into thePlantPAxProcess Automation System Visualization Using AOls and Faceplates
28. on System 23 E H Publication SP00031A 04 en 01 12 e In the Totalizers 1 2 3 screen you can configure the device totalizers and the measuring units E Module Properties EtherNet_IP_Interface Promass_ 1001 1 Z ioj x Module Info Internet Protocol Part Configuration Medium Selection System Units Supervision Totalizers 1 2 3 Process P_4 Totalizers ie ee Totalizer Blk Assign Mass Flow Unit kg ud Operation Mode Met flow total Control Maie o A Preset 0 00 Failsafe Mode Stop Y Status Running Cancel Apply Help e In the Process Parameters screen you can configure the process parameters such as Flow Override and Density Damping O Module Properties EtherNet_IP_Interface Promass_100 1 1 Internet Protocol Fort Configuration Medium Selection System Units Supervision Totalizers 1 4 3 Process Parameters C r Flow Override ut 6 Flow Damping 00 3 Density Damping 00 3 Temperature D amping OO 5 Status Running Cancel Apply Help RA Publication PROCESS AP060A EN P September 24 Promass 100 Flowmeter via EtherNet IP into thePlantPAxProcess Automation System e In the Calculated Value screen you can configure the Calculate Volume Calculation E Module Properties EtherNet_IP_Interface Promass_100 1 1 oO x Process Parameters Calculated Value External Compensation Low Flow Cut ort Partially Filled Pipe De
29. ower suppl option DO DC 24 V 2 Onder code for Output option N EtherNet IP Supply voltage for all communication types except Modbus RS4 amp 5 intrinsically safe on the device side Connector E H Publication SP00031A 04 en 01 12 RA Publication PROCESS AP060A EN P September 10 Promass 100 Flowmeter via EtherNet IP into the PlantPAxProcess Automation System Connect a Promass 100 Flowmeter 10 0 4 ve Device versions with connection examples i Cable 2 Connector for signal transmission 3 Connector for supply voltage 1 Depending on the housing version loosen the securing clamp or fixing screw of the housing cover and then unscrew or open the housing cover 2 Push the cable through the cable entry Wive ae hae 10 ensure a tight seal do not remove the sealing ring from the cable entry 3 Strip the cable and cable ends In the case of stranded cables also fit ferrules 4 Connect the cable in accordance with the terminal assignment or the connector pin assignment RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 11 5 Depending on the device version tighten the cable glands or plug in the connector and tighten WV Exe ae bmee The degree of protection for the DIP housing is voided if there is insufficient sealing of the housing Ensure that you attach the
30. rocess www endress com worldwide Americas Europe Middle East Africa International Canada Rockwell Automation Rockwell Automation Endress Hauser Endress Hauser Cahada 1201 South Second Street Vorstlaan Boulevard du Souverain 36 Instruments International 1075 Sutton Drive Milwaukee WI 53204 2496 USA 1170 Brussels Belgium Kaegenstr 2 CH 4153 Reinach BL Burlington ON L7L 5Z8 Tel 1 414 382 2000 Tel 32 2 663 0600 Switzerland Tel 1 905 681 9292 Fax 1 414 382 4444 Fax 32 2 663 0640 Tel 41 61 715 81 00 Fax 1 905 681 9444 Fax 41 61 715 25 Asia Pacific Mexico Rockwell Automation USA Endress Hauser M xico S A de C V Level 14 Core F Cyberport 3 Endress Hauser Inc Femando Montes de Oca 21 Edif A Piso3 100 Cyberport Road Hong Kong 2350 Endress Place San Nicolas 54030 Tlalnepantla Tel 852 2887 4788 Greenwood IN 46143 Edo de M xico Fax 852 2508 1846 Tel 1 317 535 7138 Tel 52 55 5321 2080 Fax 1 317 535 8498 Fax 52 55 5321 2099 E H Publication SP00031A 04 en 01 12 RA Publication PROCESS APO60A EN P September 2012 Copyright 2012 Endress Hauser Inc Copyright 2012 Rockwell Automation Inc All rights reserved Printed in the U S A
31. screw without using any lubricant The threads on the cover are coated with a dry lubricant 6 Reassemble the transmitter by reversing the removal procedure Diagnostic Information via the Light emitting Diodes Various light emitting diodes LEDs on the main electronics module of the transmitter provide information on device status LED Color eaing Power Supply voltage is off or too low supply voltage is OK Device status Device status is OK Flashing red A device error of diagnostic behavior Warning has occurred A device error of diagnostic behavior Alarm has occurred Alternately flashing red green Boot loader is active Network status Off Device has no EtherNet IP address Green EtherNet IP connection of the device is active Flashing green Device has EtherNet IP address but no EtherNet IP connection EtherNet IP address of the device has been assigned twice Flashing red EtherNet IP connection of the device is in timeout mode Link Activity Link available but no activity Flashing orange Activity present E H Publication SP00031A 04 en 01 12 RA Publication PROCESS APO60A EN P September 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAxProcess Automation System Configure the Device Address The IP address of the measuring device can be configured for the EtherNet IP network through the DIP switches for hardware addressing or through software settings The IP address for
32. software addressing 1s active when the device leaves the factory default IP address 192 168 1 212 and all the DIP switches for hardware addressing are set to OFF Addressing data IP address and configuration options Ist octet 2nd octet 3rd octet 4th octet 192 168 1 AAA 4 4 Can only be configured via software addressing Can be configured via software addressing and hardware addressing IP address range to 254 4th octet IP address broadcast Addressing mode ex works Software addressing all DIP switches for hardware addressing are set to OFF IP address ex works 192 168 1 212 software addressing Dynamic Host Configuration Protocol DHCP Client If a DHCP server is used within the EtherNet IP network the IP address gateway and subnet mask are set automatically when the DHCP client function is enabled The MAC address of the measuring device is used for identification purposes See also the connection label The default setting for the DHCP server is ON IMPORTANT peed client function is disabled if hardware addressing is enabled RA Publication PROCESS APO60A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 13 Hardware Addressing r i B F i mwg ciel ikasi IP Address aeti i 4 5 6 7 8 Tilar Anaa The Dual In line Package DIP switches can configure the last octet of the IP address
33. tection Sensor Adjustr_4 Cor Wol Calc CalcRetDensity gt Exp Coet Lir si Exp Coet Sqr 0 0 Val Ret Temp m0 C Celsius Fined Ref Density o kgl Status Running Cancel Apply Help e In the External Compensation screen you can configure the External Compensation method E Module Properties EtherNet_IP_Interface Promass_ 1001 1 Process Parameters Calculated Value External Compensation Low Flow Cut Off Partially Filled Pipe Detection Sensor Adjustr_4 Pressure E E Oft Temperature Mode Internal value Pressure 0 00000 bara Status Aunnng Cancel Apply Help RA Publication PROCESS AP060A EN P September 2012 E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 25 E H Publication SP00031A 04 en 01 12 e In the Low Flow Cut Off screen you can configure the Low Flow Cut Off function E Module Properties EtherNet_IP_Interface Promass_100 1 1 j ioj x Process Parameters Calculated yalue External Compensation Low Flow Cut OF Partially Filled Pipe Detection Sensor Adjustr_4 Assigns Volume Flow Fress Shock Supp 0 00 3 On Value 0 00000 mah Df Value SUM g Status Running Cancel Apply Help e In the Partially Filled Pipe Detection screen you can configure the Partially Filled Pipe Detection E Module Properties EtherNet_IP_Interface Promass_10
34. tion Document and Interoperability Statement help reduce risk and provide ease of integration E H Publication SP00031A 04 en 01 12 Promass 100 Flowmeter via EtherNet IP into the PlantPAx Process Automation System 3 The overall mission of the alliance is to provide proven solutions that combine field instrumentation with fieldbus networks such as HART FOUNDATION Fieldbus PROFIBUS PA and EtherNet IP networks with asset management capabilities and Rockwell Automation s system capabilities to provide a total engineered solution Through preferred integration and support of increasing requirements for plant wide control the alliance offers the following benefits e Reduced integration costs throughout engineering commissioning and start up e Optimized plant availability and output e Ensured product quality and consistency e Optimized traceability to meet regulatory demands e Predictive maintenance through intelligent instruments For new construction process improvements at an existing plant or operating cost reductions the alliance delivers the following e Certified integration reduces risk reduces integration costs and protects investment with pre engineered interoperability Both companies believe open systems and standardized interfaces bring maximum benefits e Advanced capabilities with plant wide asset management provides better visibility of plant health and easier access to instrument diagnostics which u

Download Pdf Manuals

image

Related Search

Related Contents

Raidsonic IB-550STU3S storage enclosure  Programme d`opération - Maine et Loire Habitat  Motion Sensor Light Control  3. WaveView eMbedded for Pocket PC  HD Color Video Camera User Manual  Professional Systems – Project Management Version 6.0 User Manual  Manual completo  Skross World Adapter Pro  UP-600/700 Installation-Manual GB  