1. su0495a Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U su0498a su0492a su0493a Installation UPS For UPS installation information refer to the Smart UPS X 2000 3000 VA Installation Guide that is included with the UPS The guide is also available on the enclosed CD and the APC by Schneider Electric Web site at www apc com Network Management Card For installation information refer to the user manual provided with the Network Management Card NMC The user manual is also available on the APC by Schneider Electric Web site at www apc com External Battery Pack For installation information refer to the SMX 120RMBP2U external battery pack Installation Guide that is included with the external battery pack XLBP The guide is also available on the enclosed CD and the APC by Schneider Electric Web site at www apc com 4 Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Operation Connect Equipment to the UPS CAUTION RISK OF EQUIPMENT DAMAGE e Adhere to all local and national electrical codes e Wiring should be performed by qualified electrician e Always connect the UPS to a grounded outlet Failure to follow these instructions can result in equipment damage Note The UPS will charge to 90 capacity in the first three hours of normal operation Do not expect full battery runtime capability during this init
2. ON OFF on the front panel of the UPS Adhere to all national and local electrical codes Wiring must be performed by a qualified electrician Normally open contacts 1 Ifthe EPO switch or relay contacts are normally open insert the wires from the switch or contacts at pins 1 and 2 of the EPO terminal block Use 16 28 AWG wire 2 Secure the wires by tightening the screws If the contacts are closed the UPS will turn OFF and power will be removed from the load Normally closed contacts 1 If the EPO switch or relay contacts are normally closed insert the wires from the switch or contacts at pins 2 and 3 of the EPO terminal block Use 16 28 AWG wire 2 Insert a wire jumper between pins and 2 Secure the wires by tightening the three screws at positions 1 2 and 3 If the contacts are opened the UPS will turn OFF and power will be removed from the load Note Pin 1 is the power source for the EPO circuit it provides a few milliampere of 24 V power If the normally closed NC EPO configuration is used the EPO switch or relay should be rated for dry circuit applications the rating should be for low voltage and low current applications This normally implies the contacts are gold plated The EPO interface is a Safety Extra Low Voltage SELV circuit Connect the EPO interface only to other SELV circuits The EPO interface monitors circuits that have no determined voltage potential SELV circuits are controlled by a switch
3. Slot information if applicable x Configuration Language x x Local power quality x x Standard or Advanced menus x x Audible alarms x x High and low transfer points x Low run time warning x Green mode enable disable x Output voltage x x Battery self test interval x x Battery installation date x x UPS firmware update only available when z output is off UPS setup wizard x x Reset to factory defaults x x Switched outlet group s delays and settings x Smart Slot configuration if applicable x Control Switched outlet group s Turn on turn off r put to sleep or reboot Test amp Diagnostics UPS self test x x Runtime calibration test x x Alarm and display test x x Statistics Statistics about transfers to battery power z time on battery and total operating time Logs Transfer log x Status log x Fault log x Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Main Menu Overview Standard Advanced About General information about the UPS including model numbers output voltage setting serial number manufacture date x x replacement battery cartridge information firmware versions and suggested battery replacement date SmartSlot card information if applicable x including IP address PowerChute Business Edition information r if applicable Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Configuration UPS Settings Start up Settings Use the display interfa
4. TIME e Turn off with delay WHEN ON BATTERY setting e Disabled Load Shed Time Disabled Set the value in The amount of time the outlets will function on when On Battery seconds battery power before they will turn off e Shutdown with delay e Shutdown Load Shed On i immediately Configure this time using the LOAD SHED RUNTIME i Disabled Runtime e Turn off immediately REMAINING setting e Turn off with delay e Disabled Foatohed om Set the value in When the remaining runtime reaches this level the Runtime Disabled Res seconds Switched Outlet Groups will turn off Remaining e Disabled In the event of an overload greater than 105 Load Shed on l e Enabled output the Switched Outlet Groups will immediately Overload Disabled turn off to conserve power for critical loads The Switched Outlet Groups will only turn on again with a manual command Network Management Card Settings These settings are available only on units that have a Network Management Card NMC e NMC IP Address Mode e NMC Default Gateway Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U 13 Emergency Power Off EPO Overview The Emergency Power Off EPO option is a safety feature that will immediately disconnect all connected equipment from utility power The UPS will immediately shut down and will not switch to battery power Connect each UPS to the EPO switch The UPS must be manually restarted to reapply power to connected equipment Press
5. or a network management card Function Factory Default Options Description Low Voltage 100 V 108 Vac 108 114 Vac 110 V 116 Vac 116 125 Vac To avoid unnecessary battery usage set the 120 V 127 Vac 127 136 Vac transfer point higher if the utility voltage is High Transfer 127 V 134 Vac 134 143 Vac chronically high and the connected Point Hish Voltage equipment is known to work under this o 8 8 condition The POWER QUALITY setting will 200 V 216 Vac 216 228 Vac automatically change this setting 208 V 220 Vac 220 235 Vac Note Use the Advanced Menus to configure 220 V 242 Vac 242 254 Vac this setting 230 V 253 Vac 253 265 Vac 240 V 264 Vac 264 276 Vac Low Voltage 100 V 92 Vac 86 92 Vac 110 V 98 Vac 89 98 Vac Set the transfer point lower if the utility AI O PT NETE voltage is chronically low and the connected Low Transfer 127 V 112 Vac 103 112 Vac equipment can tolerate this condition The oa t ATSE High Voltage POWER QUALITY setting will automatically 200 V 184 Vac 172 184 Vac change this setting 7 Note Use the Advanced Menus to configure 208 V 184 Vac 169 184 Vac de te 220 V 198 Vac 186 198 Vac 230 V 207 Vac 195 207 Vac 240 V 216 Vac 204 216 Vac If the UPS input voltage is between the high transfer point and the lower transfer point the aoe unit will operate in green mode Configure this setting using the Advanced menus e Normal Select the l
6. or relay properly isolated from utility power To avoid damage to the UPS do not connect the EPO interface to any circuit other than a SELV circuit Use one of the following cable types to connect the UPS to the EPO switch e CL2 Class 2 cable for general use e CL2P Plenum cable for use in ducts plenums and other spaces used for environmental air e CL2R Riser cable for use in a vertical run in a floor to floor shaft e CLEX Limited use cable for use in dwellings and for use in raceways e Installation in Canada Use only CSA certified type ELC extra low voltage control cable e Installation in countries other than Canada and the USA Use standard low voltage cable in accordance with national and local regulations 14 Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Troubleshooting Problem and Possible Cause Solution The UPS will not turn on or there is no output The unit has not been turned on Press the ON button to turn on the UPS The UPS is not connected to utility Ensure that the power cable is securely connected to the unit and to the utility power power supply Do not attempt to use the UPS Unplug the UPS and have it serviced There is an internal UPS fault immediately The UPS is operating on battery while connected to utility power Move the UPS to a different outlet on a different circuit Test the input voltage with the utility voltage display If acceptable to t
7. Arc by Schneider Electric Operation Manual oN Smart UPS X LT Low Voltage 100 127 V SMX2000RMLV2U SMX2200RMLV2U SMX3000RMLV2U SMX3000RMLV2UNC SMX3000RMJ2U High Voltage 200 240 V SMX2200RMHV2U SMX3000RMHV2U SMX3000RMHV2UNC Product Description The APC by Schneider Electric Smart UPS is a high performance uninterruptible power supply UPS The UPS provides protection for electronic equipment from utility power blackouts brownouts sags and surges small utility power fluctuations and large disturbances The UPS also provides battery backup power for connected equipment until utility power returns to safe levels or the batteries are fully discharged This user manual is available on the enclosed CD and on the APC by Schneider Electric Web site www apc com Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install operate service or maintain it The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed The following safety messages may appear throughout this manual to warn of potential hazards A CAUTION CAU
8. BPs that can be used with the UPS Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Product Overview Specifications Environmental Specifications For additional specifications refer to the APC by Schneider Electric Web site at www apc com Operating 0 to 40 C 32 to 104 F 15 to 45 C 5 to 113 F Temperature Storage charge UPS battery every six months Maximum Operating 3 000 m 10 000 ft Elevation Storage 15 000 m 50 000 ft Humidity 0 to 95 relative humidity non condensing High and Low Voltage Models Low Voltage 100 127 V High Voltage 200 240 V SMX2000RMLV 2U SMX2200RMHV2U SMX2200RMLV2U SMX3000RMHV2U SMX3000RMLV2U SMX3000RMHV2UNC SMX3000RMLV2UNC SMX3000RMJ2U 2 Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Front Panel Features Oo Battery 2 Battery connector Display interface Bezel Rear Panel Features SmartSlot Controllable Outlet Group 3 UPS input External battery pack connector Chassis ground screw EPO connector Controllable Outlet Group 1 Serial port Controllable Outlet Group 2 USB port 2200 VA Low Voltage 2000 VA Low Voltage i Eur bo oi 3000 VA Low Voltage 2200 3000 VA High Voltage su0494a
9. THERWISE OF PRODUCTS SOLD SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED DIMINISHED OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF SEIT RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES THE WARRANTIES SET FORTH ABOVE CONSTITUTE SEIT S SOLE LIABILITY AND PURCHASER S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES SEIT WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES IN NO EVENT SHALL SEIT ITS OFFICERS DIRECTORS AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES ARISING OUT OF THE USE SERVICE OR INSTALLATION OF THE PRODUCTS WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT IRRESPECTIVE OF FAULT NEGLIGENCE OR STRICT LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES SPECIFICALLY SEIT IS NOT LIABLE FOR ANY COSTS SUCH AS LOST PROFITS OR REVENUE LOSS OF EQUIPMENT LOSS OF USE OF EQUIPMENT LOSS OF SOFTWARE LOSS OF DATA COSTS OF SUBSTITUENTS CLAIMS BY THIRD PARTIES OR OTHERWISE NO SALESMAN EMPLOYEE OR AGENT OF SEIT IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY WARRANTY TERMS MA
10. TION indicates a potentially hazardous situation which if not avoided can result in equipment damage and minor or moderate injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in equipment damage Safety and General Information Inspect the package contents upon receipt Notify the carrier and dealer if there is any damage Read the Safety Guide supplied with this unit before installing the UPS e Adhere to all local and national electrical codes e This UPS is intended for indoor use only e Do not operate this UPS in direct sunlight in contact with fluids or where there is excessive dust or humidity e Be sure the air vents on the UPS are not blocked Allow adequate space for proper ventilation e The battery typically lasts for two to five years Environmental factors impact battery life Elevated ambient temperatures poor quality utility power and frequent short duration discharges will shorten battery life e Connect the UPS power cable directly to a wall outlet Do not use surge protectors or extension cords e The batteries are heavy Remove the batteries prior to installing the UPS in a rack e Always install external battery packs XLBPs at the bottom of the rack The UPS must be installed above the XLBPs e The UPS display interface will recognize as many as 10 external battery packs connected to the UPS However there is no limit to the number of XL
11. Y BE MODIFIED IF AT ALL ONLY IN WRITING SIGNED BY AN SEIT OFFICER AND LEGAL DEPARTMENT Warranty claims Customers with warranty claims issues may access the SEIT customer support network through the Support page of the APC by Schneider Electric Web site www apc com support Select your country from the country selection drop down menu at the top of the Web page Select the Support tab to obtain contact information for customer support in your region Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U 17 18 Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U APC by Schneider Electric Worldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no charge in any of the following ways Visit the APC by Schneider Electric Web site to access documents in the APC by Schneider Electric Knowledge Base and to submit customer support requests www apc com Corporate Headquarters Connect to localized APC by Schneider Electric Web sites for specific countries each of which provides customer support information www apc com support Global support searching APC by Schneider Electric Knowledge Base and using e support Contact the APC by Schneider Electric Customer Support Center by telephone or e mail Local country specific centers go to www apc com support contact for contact information For information on how to obtain local customer sup
12. ce to configure these settings at initial start up The UPS will prompt for a response to each setting if no response is given the default setting will be used Note The unit will not turn on until all of these settings are entered Function Factory Default Language English Options e English e French e German e Spanish e Italian e Portuguese Description The language for the display interface Language options will vary by model Low Voltage 120 V Output e 100 110 e 120 127 Voltage e 200 e 208 High Voltage 230 V 220 Set the output voltage setting while the UPS is in Standby mode Input Power e230 e 240 e Good Select the quality of input utility power e Fair e If Good is selected the unit will go on battery e Poor power more often to provide the cleanest power supply to the connected equipment Quality Good If Poor is selected the UPS will tolerate more fluctuations in power and will go on battery power less often If unsure of the local power quality select Good TT or The advanced menus include all parameters The Menu Type Standard Advanced Standard menus display a limited set of menus and options UPS manufacture Date date 90 days mm yyyy Enter the current date 10 Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U General Settings Configure these settings at any time using the display interface PowerChute software
13. d connected The display interface has a Site Wiring Fault message Wiring faults detected include missing ground hot neutral polarity reversal and overloaded neutral circuit If the UPS indicates a site wiring fault have a qualified electrician inspect the building wiring Applicable for Low Voltage 120 V units only Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U 15 Service If the unit requires service do not return it to the dealer Follow these steps 1 Review the Troubleshooting section of the manual to eliminate common problems 2 If the problem persists contact APC by Schneider Electric Customer Support through the APC by Schneider Electric Web site www apc com a Note the model number and serial number and the date of purchase The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models b Call APC by Schneider Electric Customer Support and a technician will attempt to solve the problem over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA c If the unit is under warranty the repairs are free d Service procedures and returns may vary internationally Refer to the APC by Schneider Electric Web site for country specific instructions 3 Pack the unit in the original packaging whenever possible to avoid damage in transit Never use foam beads for packagi
14. e the Configuration menus to configure how the Switched Outlet Groups will react in the event of a power outage 12 Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Customize the Switched Outlet Groups Use the Control menus to customize the Switched Outlet Groups Function Factory Default Options Description Name String Outlet Group UPS Name String APC UPS Outlet Group 1 2 3 Edit these names using an external interface such as the Network Management Card Web interface The amount of time the Switched Outlet Groups will Set the value in se Turn On Delay 0 sec seconds wait between receiving the command to turn on and the actual startup Set the value in The amount of time that the Switched Outlet Groups Turn Off Delay 90 sec will wait between receiving the command to turn off seconds and the actual shut down Set the value in The amount of time that the Switched Outlet Groups Reboot Duration 8 sec Saas seconds must remain off before it will restart The amount of battery runtime that must be available DA UE RER 0 sec Serie valle before the Switched Outlet Groups will turn on again Time seconds after a shutdown e Shutdown with When the unit switches to battery power the UPS can Delay disconnect power to the Switched Outlet Groups to e Shutdown save runtime Load Shed On Disabled immediately Battery e Turn off immediately Configure this delay time use the LOAD SHED
15. evel of sensitivity to power e Reduced events that the UPS will tolerate e Low e Normal The UPS will go on battery power more often to provide the cleanest power supply to the connected equipment e Reduced The UPS will tolerate some Transfer Normal fluctuations in power Sensitivity e Low The UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power disturbances set the sensitivity to Normal using the advanced Configuration menu Low Runtime Set the value in The UPS will emit an audible alarm when 2 150 sec ae Warning seconds the remaining runtime has reached this level Date of Last Battery Date set at factory Reset this date when the battery module is replaced Replacement Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U 11 Function Factory Default Options Description The UPS will never beep if all audible Audible Alarm On On Off alarms are set to Off or when the display buttons are pressed e Last test 14 days e Last test 7 days Auto Self Test On start up and every 14 Turn on 14 days Interval Setting days since the last test Turn on 7 days e On startup only e Never The interval at which the UPS will execute a self test The batteries much be charged to at least 70 capacity to perform the test Reset to Factory No Default Yes No Restore the UPS factory default settings Switched Outlet Gro
16. he connected equipment There is very high very low or distorted redhie the UPS sensitivity input line voltage or frequency Test the utility input power to ensure the unit is receiving input power UPS is emits intermittent beeps The UPS is protecting the connected equipment See the display interface to The UPS is in normal operation view the status of the UPS UPS does not provide expected backup time Charge the battery Batteries require recharging after extended outages and The UPS battery is weak due to a recent wear out faster when put into service often or when operated at elevated outage or is near the end of its service temperatures If the battery is near the end of its service life consider life replacing the battery even if the replace battery indicator is not yet illuminated The UPS is overloaded Check the UPS load display Unplug unnecessary equipment such as printers The Fault LED is illuminated The UPS displays a fault message and emits a constant beeping sound Do not attempt to use the UPS Turn the UPS off and have it serviced Internal UPS fault immediately The Replace Battery LED is illuminated Allow the battery to recharge for at least four hours Then perform a self test Ae PADIN DAR AVEA HAEE If the problem persists after recharging replace the battery The replacement battery is not properly Ensure that the battery connector is securely connecte
17. ial charge period 1 Connect equipment to the outlets on the rear panel of the UPS 2 Connect the UPS to the building utility power Always connect the UPS to a two pole three wire grounded source 3 To use the UPS as a master ON OFF switch turn on all the equipment that is connected to the UPS 4 Press the ON OFF button on the front panel of the UPS to turn on the UPS and all connected equipment See Switched Outlet Groups on page 12 for information on how to use the switched outlet groups M at Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Basic Connections LC Q Serial port Connect to a computer to use power management software use the serial cable included with the unit USB port Connect to a computer to use power management software Note Serial and USB communication can not be used simultaneously External Battery Pack connector Connect external battery packs to provide extended runtime during power outages The UPS can support up to 10 external battery packs Ground Screw The UPS features a ground screw for connecting the ground leads on transient voltage devices Prior to connecting a ground lead disconnect the UPS from utility power Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Display Interface Overview Online LED UPS Output On Off button On Battery LED Site Wiring Fa
18. ng Damage sustained in transit is not covered under warranty a Always DISCONNECT THE UPS BATTERIES before shipping The United States Department of Transportation DOT and the International Air Transport Association IATA regulations require that UPS batteries be disconnected before shipping The internal batteries may remain in the UPS b External Battery Pack products are deenergized when disconnected from the associated UPS product It is not necessary to disconnect the internal batteries for shipping Not all units utilize an external battery pack 4 Write the RMA provided by Customer Support on the outside of the package 5 Return the unit by insured prepaid carrier to the address provided by Customer Support Transport the unit Shut down and disconnect all connected equipment Disconnect the unit from utility power Disconnect all internal and external batteries if applicable Pe eS Follow the shipping instructions outlined in the Service section of this manual 16 Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Two Year Limited Factory Warranty This warranty applies only to the products you purchase for your use in accordance with this manual Terms of warranty Schneider Electric IT SEIT warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase SEIT will repair or replace defective products covered by this warranty Thi
19. port contact the APC by Schneider Electric representative or other distributors from whom you purchased your APC by Schneider Electric product a Select models are ENERGY STAR qualified For more information go to www apc com site recycle index cfm energy efficiency energy star PA 2013 APC by Schneider Electric APC the APC logo Smart UPS and PowerChute are owned by Schneider Electric Industries S A S or their affiliated companies All other trademarks are property of their respective owners 990 3651D 04 2013
20. s warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way Repair or replacement of a defective product or part thereof does not extend the original warranty period Any parts furnished under this warranty may be new or factory remanufactured For country specific warranty information refer to the APC by Schneider Electric Web site at www apc com Non transferable warranty This warranty extends only to the original purchaser who must have properly registered the product The product may be registered at the APC by Schneider Electric Web site www apc com Exclusions SEIT shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user s or any third person s misuse negligence improper installation or testing Further SEIT shall not be liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection inappropriate on site operation conditions corrosive atmosphere repair installation exposure to the elements Acts of God fire theft or installation contrary to SEIT recommendations or specifications or in any event if the SEIT serial number has been altered defaced or removed or any other cause beyond the range of the intended use THERE ARE NO WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR O
21. ult LED Replace Battery LED Display screen UP DOWN arrow buttons ENTER button 00000000 ESCAPE button O nL be o E EE su0343a Using the display interface Use the UP DOWN arrow buttons to scroll through the main menu options Press ENTER to view the submenu under each main menu option Press ESCAPE to exit a submenu and return to a main menu Menu Overview The Smart UPS has Standard and Advanced menu screens The Standard menu screens are the most commonly used screens The Advanced menu screens are for more advanced users to configure additional features on the UPS Note Actual menu screens may vary Main Menu Overview Standard Advanced penolling Screens detre operating on utility power x Outlet Group Status x Input and Output voltage x Load meter x Battery charge and runtime x Warnings x Load and Battery graphs x Status Operating Mode x x Efficiency in Green mode only x x Input and output voltage x x Smart UPS X 2000 2200 3000 VA 100 120 230 Vac Tower Rack Mount 2U Main Menu Overview Standard Advanced Load power W and VA x x Load A x Load meter kWh x Last transfer to battery power information x x Battery charge and estimated run time x x Battery voltage x Number of external battery packs x Internal battery temperature x Run time calibration test results x x Self test results x x Status of the switched outlet group s On Off Sleep Reboot Turning On Turning Off Smart
22. ups Overview The Switched Outlet Groups can be configured to independently turn off turn on shut down put into sleep mode and reboot connected equipment The Switched Outlet Groups can be commanded to do the following e Turn off Disconnect from power immediately and restart only with a manual command e Turn on Connect to power immediately e Shutdown Disconnect power in sequence and automatically reapply power in sequence when utility power becomes available e Reboot Shut down and restart e Sleep Reboot after a long delay In addition the Switched Outlet Groups can be configured to do the following Turn on or off in a specified sequence e Automatically turn off or shut down when various conditions occur Note Whether the Switched Outlet Groups are configured or not all of the outlets provide battery backup power Using the Switched Outlet Groups 1 Connect critical equipment to a Switched Outlet Group 2 Connect peripheral equipment to the other Switched Outlet Groups During a power outage to conserve battery runtime nonessential equipment can be configured to shut down after a short delay If equipment has dependent peripherals that must restart or shut down in a specific order such as an ethernet switch that must restart before a connected server connect the devices to separate groups Equipment that needs to reboot independently from other equipment should be added to a separate group 3 Us