1. a 3 a Back Y Submit Preyveiw Setup Recording setup Alarm device Motion detect setup Error setup Video parameter San ea a eee eae a ia Abe action MA cgay ce oe so dae TEE EE Sees PTZ setup Color scheme schedule HIER Eech e ae Ee CAN Matrix setup Other device Network setup Advanced setup HR HF FF Customization Fig 9 6 ale Homepage Back Submit zk Animation effect w Animation time Fast je Slow Animation direction Right O Left Fig 9 7 Preview Setup The Preview Setup menu contains the Video Parameter p 84 Color Scheme p 84 and the Color Scheme Schedule p 84 The Video Parameter page Fig 9 8 allows you to change the video format to PAL or NTSC using the Standard radio buttons You can change how the OSD displays the date by using the Date Format drop down box Video parameter Standard O PAL 2 NTSC Date format MM DD YvrY D Fig 9 8 83 Unisight DVR System The Color Scheme allows you to change the brightness contrast saturation and hue of each individual video channel Fig 9 9 Up to five different Color Schemes can be set here using the Color Scheme drop down box Use the Default button to restore the color settings to the originals You can also create motion zones here To create a motion zone left click and drag a square around the desired area You can create multiple motion zones each with a unique sensitivity
2. CH O3 Wednesday i Schemel 4 Scheme4 CH 04 Thursday 1 Schemei 5 Scheme5 Friday 1 Schemel 6 Schemes Saturday i Scheme 7 Scheme Holiday 1 Schemel 8 Schemes Holiday setup Delete All Copy to w Activate schedule Scheme 1 Edit capia Fig 9 10 Holiday setup Holiday 1 30 Select date 5 M WU T F 5 1 2 3 4 sl 7 8 10 11 12 13 14 15 16 17 18 19 20 21 22 dd 24 25 26 27 26 AH 30 21 Delete Clear Fig 9 11 85 Unisight DVR System The Holiday Setup button will open the Holiday Setup page Fig 9 11 You can add up to 30 dates to the Holiday list To add a date left click a day on the calendar to highlight it Now click the left arrow to add the date to the list To remove a date from the list left click the desired date and click the Delete button To empty the entire list click the Clear button To edit a Time Scheme click the Edit button The Time Scheme page will appear Fig 9 12 To configure a Time Scheme click on Schemel Schemel6 Use the Period blocks to fill in a time period for the scheme You can also use the Standard drop down box to apply common time periods to the scheme Use the Name field to change the name of the scheme Click the Clear button to remove all time periods from the scheme Click the Save button to save the Time Scheme 0 00 23 39 Scheme 18 00 23 39 18 00 23 39 Scheme Schemes Schemes Period 00 00 23 59
3. E Snapshot PA Record hd Download Fig 9 62 These buttons are from left to right Connect Selected Channels Disconnect Current Channel and Disconnect All Channels Fig 9 63 The Connect Selected Channels button will establish a connection to the currently selected video channels in the Available Channel List in the currently selected grid The Disconnect Current Channel button will drop the connection to the currently selected video channel on the channel grid The Disconnect All Channels button will drop the connection to all video channels Ke Fig 9 63 These buttons are Volume Set Color Set and PTZ Control Fig 9 64 The Volume button will allow you to change the audio volume Fig 9 65 Use the and buttons to raise or lower the volume You can also use the slider to change the volume To return to the DVR Control Buttons click the Volume button The Video button allows you to change the brightness contrast saturation and hue Fig 9 66 Left click the Video button to return to the DVR Control Buttons Volume Fig 9 64 111 Unisight DVR System Wolume Fig 9 65 The PTZ Control button allows you to pan tilt and zoom any configured PTZ cameras on the DVR Server Fig 9 67 Not all PTZ cameras support all PTZ control buttons If you click on a button that is unsupported by the PTZ camera nothing will happen Left click the PTZ button to return to the DVR Control Buttons Fig
4. My SMTP server need checking authorization Account name Passweord Fig 3 19 30 Unisight DVR System Relation Tab Fig 3 20 Here you can configure any supported alarm relay controller module that you have connected to the Unisight DVR Serer Channel list Camera Color Motion Schedule Alarm actions Relation Guard schedule PTZ Advanced Environment Sensor 2 sensor property Standard mode sensor 03 Sensor 04 Link to output Link to video channel Sensor 05 sensor 06 sensor DOP Sensor 06 Sensor 09 sensor 10 sensor 11 sensor 12 sensor 13 sensor 14 Sensor 15 sensor 16 Copy to High Server name High techstation High High High High Import config gt Clear Export contig Log User gt E Map Apply Cancel Fig 3 20 CH CH E High High High Output 04 High a CH o CH La Pa CH CH E a Output 05 High Output 06 Ho Output 07 High Output 08 High High High CH CH wn CH CH O pari O Koch Kb CH oul To configure each sensor connected to the alarm relay controller select a sensor from the Sensor List and click the Sensor Property button The Sensor Property dialog box will appear Fig 3 21 Determine if your sensor is a high or low level trigger and select the appropriate radio button The ID field
5. O00 e Server name Auto shutdown si Power off when shutdown techstation Auto start Si ee e w Enable local web server Limit each client user accessing from one IP address simultaneously Import contig Export contig gt Log gt User gt E Map gt Apply Cancel Fig 3 43 Environment The Enable Client Connection check box needs to be checked to allow remote client users to successfully connect to the server A log is created for every day that the server is running To change the number of days that these logs are stored type in the desired number into the Log Info Keeping Period field To have the Unisight DVR Server automatically restart check the Auto Restart check box To specify when this restart will happen select the desired day hour and minute using the 41 Unisight DVR System corresponding drop down boxes It is recommended to restart at least once a week To shutdown automatically check the Auto Shutdown check box and fill in the day hour and minute drop down boxes Auto Shutdown will only shutdown the Unisight DVR software application To have the entire Unisight DVR Server turn off check the Power Off When Shutdown check box The server application can be scheduled to automatically start at a specified time To enable this feature check the Auto Start check box and select the desired hour and minute using the drop down boxes To enable the Unisight DVR Web Server check the Enable Local Web Server
6. Memo CH 04 Allow network access w Extend infomation Fig 9 49 105 Unisight DVR System The Channel Associated page is where you can rename individual video channels Fig 9 49 Start by selecting a video channel from the Channel List it will highlight green The Signal Lost Alert check box will display a signal lost graphic on the video channel that has been disconnected If the Messenger Service is enabled a dialog box will popup informing you of which channel has been disconnected The Show Preview check box will enable the video feeds for the Live Preview mode Without this checked you will not see your cameras The Memo check box enables a memo addition to each channel that pops up each time a manual recording is started The Allow Network Access check box will grant remote users access to the video channel You can attach additional information to a recorded video file by using the Extend Info field The Time Scheme Setup page allows you to customize each of the time schemes Fig 9 50 a LI Vd 0 00 23 39 Scheme Scheme Scheme PRETERE 18 00 23 59 Scheme Scheme Scheme Period 00 00 23 59 Name Schemel Fig 9 50 Start by selecting a scheme by left clicking the scheme name it will highlight green Use the Name field to type in a name to identify the scheme The Standard Mode drop down box contains pre configured common time periods Use the
7. Remote Syne Playback ASAS a 61 SHODSHOU conidial indents A E eee 61 Browse And Print Image bie 61 Mannal Selde EE 62 ER Ebbe 62 CHENE SQUAD so Ee GE EE 65 THSIGUWQUON EE N N DEE OE ate 65 TIL MAREE ee EES Ed Ge NE BE SAGE RE AS ee ige de 65 SE AR OO AE AE OE NE OO IR GE 65 DVR Information Minden 65 Grid LOVOUL EE 66 Camera Mams EDS ics csi EES DE ce oe De EG GE Die 67 DVR Control Buttons 67 E ra BUU OT ee 68 e er ET ds ida al 68 DUAD 10 AE Ee 68 SUAS OU EE 68 PIT Preset OS TINA iia 68 E EE 69 AVAL AE N AE N 69 AUS FIZ EE 69 Control Remote Host Machine 69 Star ta VOICE EE 69 Video POI GINCICVS text dE Ebbe 69 DISCONNCCE EE 70 TUNES EE 70 Channel Extendida 70 Connec DOM e tac GE A ace ase 70 MY ASe OE OE EE Gat say N EE DE 71 COMM eon laD ANA a 12 LOO VIEWED 12 Unisight DVR System EE 74 RE 74 Advanced 10D EE EE 75 KI 75 EVI ONIN EE gg 75 Evironment LADA A EE TI KEE TI EE 71 REMOTE CONTEO RR GE RR ER GE GE tiie 78 Client NEE 79 Backup Files Remote DOWIMILOOG oi RS ES GE GE EO 79 Web CENT AAA A A AA ed 80 dee 80 REMOVE ELUD IAS br 82 EE Ee 83 AAA EE 84 Color SCONCE a eee HE AE N HER ees 84 Color Scheme Schedule iii Gnesi od og Ge EE Ge DE 84 EE Eet EE 86 RECAM SENSE Verena deus E 86 MACS MMC 87 Vide Scheme Schedule y AAA ah eek AA AAA 88 CONMMUOUS SCNCAU Ca EER AAA AAA 88 POT AI rr iia 88 DEVICE EE 88 sensor AMO EE 90 EE 90 Sensor Relation TO DUDE DE GE EE ED EE DE Baan DE eg Re 91 Sensor
8. and Playback p 119 In the top right there is a Refresh button that will update the page 8 Unisight DVR System sper OK Clear Fig 9 4 DIGITAL VIDEO NETWORK LINISIGHT SURVEILLANCE _ a SYSTEM D Remote status Fig 9 5 Remote Setup Fig 9 6 The Remote Setup allows you to configure all of the Setup Options p 19 that are on the Unisight DVR Server application On the top right of the screen there is a Personal button This button will open the Personal Configuration page Fig 9 7 The Animation Effect check box will toggle the rotation animation for the Remote Setup The Animation Time slider will increase decrease the speed of the Animation Effect You can choose whether the Animation Effect rotates to the right or to the left using the Animation Direction radio buttons The Remote Setup page contains 12 menu items Preview Setup p 83 Recording Setup p 86 Alarm Device p 88 Motion Detect Setup p 91 Error Setup p 92 Alarm Action p 94 PTZ Setup p 98 Matrix Setup p 100 Other Device p 102 Network Setup p 102 Advanced Setup p 104 and Customization p 107 Left click on the menu item to open the respective pages The Homepage button will open the Web Client Main Screen The Back button will open the last open page The Submit button will save and apply the changes to the Unisight DVR Server Unisight DVR System Remote setup C Z 5 E I
9. configurations for each external alarm output device Fig 9 19 To select an alarm output device left click an Output from the Output List The Output Description field allows you to change the name of the output device You can also set the mode of operation for the output device using the Trigger radio buttons By default High is selected By selecting Low the output device would be normally open as opposed to normally closed Output List Output info setup Output description Output 01 Trigger Gei High O Low gt Output 02 H gt Output 03 gt Output 04 D Fig 9 19 Standard mode Clear Sensor 01 relation to outputs Description Output 2 Sensor 02 Output 03 3 Sensor 03 Output 04 4 Sensor 04 Output 05 ei Sensor 05 Cutput 06 6 Sensor 06 Output OF 7 Sensor OF Output 06 8 Sensor 08 Output 09 3 Sensor 09 Output 10 10 Sensor 10 Output 11 11 Sensor 11 Output 12 12 Sensor 12 Output 13 13 Sensor 13 Cutput 14 14 Sensor 14 Output 13 15 Sensor 15 Output 16 Fig 9 20 90 Unisight DVR System The Sensor Relation To Output page allows you to link sensors to outputs Fig 9 20 Select a sensor by left clicking it will highlight green Now select which output for the sensor to trigger by selecting an output and clicking on the left arrow The output will be added to the list To remove an added output click the right arrow To clear
10. 09 13 83 32 2007 10 09 13 83 22 00 10 09 13 83 32 VD DI zl om cn BE HI r Channelo Channel Channel Channel Channel Channeloz Channel Channel Channellz Channelo 2007 10 01 2007 10 01 2007 10 01 2007 10 01 2007 10 01 2007 10 01 2007 10 01 2007 10 01 2007 10 01 2007 10 01 10 07 49 2007 10 01 10 09 45 2007 10 01 10 16 56 2007 10 01 10 19 20 2007 10 01 10 19 16 2007 10 01 10 22 05 2007 10 01 10 42 14 2007 10 01 10 23 06 2007 10 01 10 43 19 2007 10 01 101231590 2007 10 01 Select all Inverse Clear all Delete Total files 355 Selected files 1 Fig 6 12 60 10 08 14 10 09 59 10 17 11 10 19 46 10 19 46 10 24 46 10142146 10 2322 10 24 06 10 44 06 Backup Unisight DVR System Remote SYNC Playback In local Playback you have 2 modes the Local File Search Mode and Local Synchronizer Search Mode Click the Remote SYNC Playback button Fig 6 13 The Remote SYNC Playback dialog box will appear Fig 6 14 Using the Playback Mode drop down box you can select between the two modes The Local File Search Mode will playback the recorded video files locally This means that if you set the Single File Recording Time to 30 minutes the Unisight DVR Server will load that entire 30 minute video file before it starts playing it back The larger the Single File Recording Time the longer it will take to load each recorded video file The Local Synchronizer Search Mo
11. 37 buttons To close the Instant Playback dialog box left click the Exit button Fig 3 38 Fig 3 31 Fig 3 32 Fig 3 33 Fig 3 34 d Fig 3 35 Fig 3 36 Fig 3 37 Fig 3 38 Fig 3 39 Fig 3 40 39 Unisight DVR System To take a Snapshot of the Instant Playback video left click the Snapshot button Fig 3 39 The Snapshot dialog box appears p 45 To save the Instant Playback Video left click the Save button Fig 3 40 The Files Backup Manager will appear Fig 3 41 You can input a label for the folder that the video will be stored in by using the Label drop down box You can also change the name of the physical file that will be created by changing the Filename text field Click the Backup button to continue the backup process The Select Path dialog box will appear Fig 3 42 Select the desired Device Type and drive from the Drive List Click the Save button to complete the process Files backup manager File backup Label InstPlay Filename InstantPB 20071022 1 55237 Backup USB devices gt Fig 3 41 Select path El Device type Local disk Drive list CH Free space B1670 MB4 Space needed 5 91 MB Save Cancel Fig 3 42 Import Export Config You can choose to import or export your Unisight DVR Server configuration This allows you to copy your configuration to another Unisight DVR Server to quickly setup multiple DVR Servers To export your configuration c
12. Fig 3 25 Configure each drop down box as specified by the manufacturer 35 Unisight DVR System Advanced Tab Fig 3 26 Video Standard During the Initial Startup p 9 the video standard was already selected and should not need configured Using the Date Style drop down box you can change how the date is displayed on the OSD Recording Setup The Single File Recording Time allows you to select the maximum amount of time before a new recording file is created Remember that you cannot create a clip that spans multiple recording files The Minimal Disk Space is the amount of free space needed on a drive to record video to The Auto Overwrite feature will automatically overwrite the oldest video recording when drive space has run out The Disk Switching Alert will give an alert every time the Unisight DVR Server starts recording video to a different drive SS Setup Channel list Camera Color Motion Schedule Alarm actions Relation Guard schedule PTZ Advanced Environment Video Standard PAL e NTSC Date style Mk D I Wii Recording setup Single file recording time 10 Minute Disk number o Channel Number Minimal disk space 2040 MEH 28 4096 Auto overwrite Disk switching alert Others vw Hi aualts playback Messenger Service Audio preview Voice chat vw Status info Instant playback Server name Watchdog Unisight COM port techstation Matrix COINDSME snapshot path C Snapshot Data Import
13. Grid The channel grid contains the live video preview This is where you will see all of your video feeds You can select each channel by left clicking the mouse to activate the live audio preview for that channel To maximize a video channel double click it You will notice that once maximized you will also see the other connected video channels in a picture in picture on the lower right To restore the Channel Grid double click the video feed again There is also a full screen mode that you can toggle by clicking the right mouse button on any video channel Grid Layout Buttons You can rearrange the Channel Grid using the Grid Layout buttons Hover your mouse cursor over the buttons to see what each one does Fig 9 58 L UO EH EA H LA HE ki EH EA Lal EI Fig 9 58 Available Channel List All available channels to connect to are listed here Fig 9 59 To select a single video channel left click on the name and it will be highlighted To select multiple video channels hold down the Ctrl key and left click on the video channel names The Select All button will highlight all available video channels Fig 9 60 The Invert button will change the current video channel selection to the exact opposite Fig 9 61 110 Unisight DVR System Fig 9 59 Invert Fig 9 60 Fig 9 61 DVR Control Buttons These buttons are Snapshot p 113 Start Recording p 113 Remote Download p 113 and Playback p 114 Fig 9 62
14. Relation To Channel ie pane Se AE GE 91 Guardas che dle si RS OA 91 MOON Dele ci Sel Date Ee De De We 91 Motocicleta 91 EE 91 LIOS UD ER OE EE RE OR ER 92 BIYO RESPONSER OIE N OR OE RE EO DIG 92 ATEMA De ee RE DR EE ds 94 Alarm And Motion Det HOW es EERS ES saan SE ES nad ns BEE SR DER anes ee 94 Channel Relation To OUDHEDE EE EE ED 95 Channel Relation 10 Snaps hol ira 95 Short Message SU A ae ees Owed AGS 95 EE 97 EE EE 97 ER 97 EE 98 Unisight DVR System VD EE 98 EE 98 Sensor Relation To Preset POE 100 MATIX CD iaa 100 II E E 100 sensor Relation EE 101 Oer BLA a OE CTCL ET Tee CET 102 ICV DOIN OER MA ci ale 102 ES CUNA TE Ee 102 NERO EE 102 NOCIVOS CUDASS ARIAS AS RANA 102 Network Sch dule o a A da 102 AVANCE UD ii E 104 YEN CUDASS AAA A 104 NA A RN EE O REE 105 Channel ASSOC AICO iras dc 106 EE 106 PAOLA SCID A A ey ean en Se nant 106 CUSTONNIZON OM A a EE MERK 107 EE E E os 108 ADGA S Ci te wae EE 108 Delete USE as ass 108 Ee EE 108 E less AA A id 109 COMET OAICCESS eebe 109 St EE 109 EE E ai ds 110 EE Eege 110 Available CRIAR CL A as 110 DVR Control BuHOnS EES ERGE A ta 111 EE 113 EEN 113 Remo DOWHIOOG ee Sege E 113 EE 114 EN 115 Teno e DIGUUS EE EE N 116 DUST CIU ERA 116 EEN 116 AVOIR TOTS EEN Ehe EE EE A 116 Pie EE EA nde ade di ia diri 116 Sen KOOS ee ER Re ene eee aa ee SE 116 Remote EEN 116 Channel Go OE e els 117 ER de dut co GE 118 Unisight DVR System Alarm EE Windows Control Re
15. The Speed field will display the current playback speed Use the Decrease Speed button to slow the playback speed down to 1 4 real time speed Use the Increase Speed button to speed up playback up to 16x real time speed Use the Time Slider to quickly search through the playing recorded video file 119 Unisight DVR System Contact Us Unisight Phone 303 680 6629 Fax 303 680 6630 E mail info unisight net Web http www unisight net 14824 E Hinsdale Ave Suite A Centennial CO 80112 120
16. a different Folder click Browse and select another Folder Click Next to continue Destination Folder C Program Files Unisight DYR Browse Space required 21 2MB Space available 63 866 Mulsoft Install System v2 29 Fig 1 2 Unisight O R Choose Start Menu Folder Choose a Start Menu folder For the Unisight OR Software shortcuts Select the Start Menu Folder in which you would like to create the program s shortcuts You can also enter 4 name to create a new Folder Accessories activePDF Administrative Tools Intel R Matrix Storage Manager Microsoft Office Microsoft Windows Embedded Studio MySQL DW Do nat create shortcuts Mullsoft Install System v2 29 Fig 1 3 10 Unisight DVR System The Unisight DVR software will now be installed Once the progress bar has completely filled in click the Close button to exit the installer Fig 1 4 You are now ready to start the Unisight DVR application Unisight DR Installation Complete Setup was completed successfully Completed Show details Mullsoft Install System v2 29 lt Back Close Cancel Fig 1 4 11 Unisight DVR System Install DVR Hardware Once the software installation has been completed it is time to install the required video capture card and its associated driver Turn off the system and disconnect the power cable Wait at least 30 seconds to allow any remaining electrical power time to dissipate to prevent possible e
17. alarm relay controller Set the IO Address to match the setting of the alarm controller 88 Unisight DVR System LJNISIGHT Homepage Ki Back Submit Preveiw setup Remote setup Recording setup Alarm device Motion detect setup ds SE EE EE E e pry Ship Gutput info setup s cides eee dic DE ee gf Y setup Sensor relation E cerrar a a a other dame Sensor relation to channel rodri RN Y natok setup Guard srheduia ver arena E EE Advanced setup Customization Fig 9 16 Device type Mainvan0808 COM COMI Baud rate 9500 Data bit feel Parity None Stop bit 10 Address PF Fig 9 17 Sensor info setup Sensor description Sensor 01 Sensor ID Sensor 02 Trigger High O Low Sensor 03 gt Sensor 04 D Fig 9 18 89 Unisight DVR System The Sensor Info Setup page contains all the setup options for each external sensor connected to the Unisight DVR Server through an alarm controller Fig 9 18 Select a sensor by left clicking on it on the Sensor List To change the name of a sensor use the Sensor Description field The Sensor ID field needs to match the ID that the sensor 1s connected to on the external alarm controller You can set the sensor trigger to either High or Low using the Trigger radio buttons The Trigger will reverse the operation of the sensor if switched from the default The Output Info Setup page contains the
18. attention and will not change without user input either by double clicking the single screen or by clicking one of the Grid Layout buttons 25 Unisight DVR System Type Unizight Device property COM port IO Address HEX Fig 3 8 Baud rate Parity Fig 3 10 26 Unisight DVR System The Alarm Recording check box will toggle alarm recordings Alarm recordings include motion detection and external sensor triggers The Show Motion Area check box toggles the motion detection zone box on the Live Preview p 14 The Enable Motion Log check box when enabled writes a log entry every time a motion recording is started and every time a motion recording is stopped The Single Screen Preview feature will maximize any video channel that senses motion If more than one video channel senses motion the Single Screen Preview will cycle through each video channel The Error Motion Output Trigger check box will enable motion detection based alarm relay controller triggering This must be enabled if you want motion to trigger an alarm device The Show Local Alarm Light check box toggles the display of a visual alarm light in the center of the screen during alarm conditions The Enable Voice Alarm check box toggles an audible sound that plays through the speakers connected to the Unisight DVR Server By default a beeping tone will be heard if no sound files are configured To select a different sound file click the Alarm Respo
19. check box The Limit Each Client User Accessing From One IP Address Simultaneously check box is a security measure If it is checked only client user can access the Unisight DVR server from the LAN For the Unisight DVR Server to be accessible from remote locations you must forward ports through your router to the DVR machine To configure which port is used click the Network Ports button Input the desired port number for the HTTP Port which is used for the Web Server and the Server Message which 1s used for the remote clients Fig 3 44 Network ports setting HTTP port Server Message Fig 3 44 To synchronize the system clock to local time click the Adjust Clock button The System Clock dialog box will appear and allow you to change the time and date Fig 3 45 System clock DI F200 10 46 13 AM Fig 3 45 The User button will allow you to add delete users and to modify their permissions Fig 3 47 To get an updated list of configured users click the Refresh button Fig 3 46 ba Fig 3 46 42 Unisight DVR System User admin File View Tools Status Full name Description Active Default user Admin Administer the system Active Network 1 Network access user Advanced Active Network 2 Network access User 2 Medium Active Networkt 3 Network access User 2 Lowy Active Network Network access userid Fig 3 47 To delete a user from the system click the Delete button Fig 3 48 T
20. either save or discard the clip you just created If you wish to discard the clip press the Clear button If you wish to save your clip press the Ok button Once you press the Ok button the Clip Video File dialog box will disappear and the Files Backup Manager will open up p 62 The Smart Search button will open the Smart Search dialog box will appear Fig 6 8 The Smart Search is divided into two sections the Video Preview Windows and the Smart Search Control Set The Video Preview Windows display the Playback video and the Search video The Control Set displays all the Smart Search buttons along with the Video Results 57 Unisight DVR System E Smart search Playback window No Searchtime 1 007 10 23 09 40 10 Z 2007 10 23 09 43 13 3 00 10 23 09 46 16 4 00 10 25 09 46 16 LE 00 10 23 09 48 15 16 0007 10 23 09 46 16 17 00 10 25 09 46 16 A 07 10 23 09 46 16 ig 00 10 23 09 45 16 10 0007 10 23 09 46 16 NN 00 10 25 09 46 16 12 07 10 23 09 46 16 113 00 10 23 09 0 10 14 2007 10 23 09 46 16 n TAT 1 ma ato 1 Bookmark History Result Dr mf setup Search 2007 10 45 08132103 2007 10 23 00 32 24 2007 10 23 08 32 29 2007 10 23 08 32 40 00 10 43 08 33 15 2007 10 23 00 35 30 2007 10 23 08 33 55 00 10 43 00 34 12 2007 10 23 00 04 15 2007 10 25 00 04 26 00 10 43 00 35 09 2007 10 23 00 35 50 007 10 23 08 36 08 2007 10 23 00 36 40 2007
21. gt sermname lt All gt Server Message Cancel Fig 7 19 73 Unisight DVR System The Parameters button will open up the Remote Setup window p 82 The Remote Setup will allow you to configure the settings of the Unisight DVR Server remotely using the Unisight DVR Client application The User Admin button will open the Remote User Admin window p 108 This will allow you to add modify remove users from the Unisight DVR Server remotely using the Unisight DVR Client application The Group Setup button opens the Group Info dialog box Fig 7 20 Left click the group name to highlight it You can change the name of the selected group using the Description field The Enable Auto Switching check box will cycle through each configured group The Switching Interval field specifies how many seconds the selected group will display before switching to the next group Le e Th Group info Group 01 Pe Group 02 Group 05 Sroup 04 Group 05 roup O6 Group 07 Group 08 Group 09 Group 10 Group 11 FOLUE 12 Group 13 Group 14 Group 15 Group 16 Group 17 Group 16 Wi Enable auto switching Switching interval Description Fig 7 20 Record Tab Fig 7 21 The Single File Recording Time drop down box specifies the maximum length of a recording file before a new file is created The longer the recording file time the longer it takes to load before playing back Be aware that you cannot create a clip tha
22. have not installed the client Actives control please download and install it first and wait for the successful hint Fig 9 1 80 Unisight DVR System File Download Security Warning Do you want to run or save this file Mame TCVideo exe Type Application 3 75 MB From 127 0 0 1 Aun While files from the Internet can be useful this file type can potentially harm your computer If vou do not trust the source do not run or save this software what s the risk Fig 9 2 The TCNVC exe ActiveX control will now be downloaded and installed Wait for the TCNVCInstall dialog box to appear and click the Ok button Fig 9 3 You must restart your browser now TCVideo D i 1 Client plugin component has been installed successfully Fig 9 3 Once your browser has been restarted type in the IP address ofthe DVR Server in the Address Bar starting with http Choose English Fig 9 0 Then click the Enter button Fig 9 1 You will be prompted with a login screen Fig 9 4 Type in your Username and Password and click the Submit button The Clear button will remove all text from the Username and Password fields After you log into the Unisight DVR Web Server you will be presented with the Web Client Main Screen Fig 9 5 There are eight buttons Remote Setup p 82 User Management p 108 Preview p 109 System Information p 115 Remote Status p 116 System Logs p 116 Remote Control p 116
23. individual channel Fig 9 23 Use the Hint Message field to add text This Hint Message will be included in the e mail automatically sent if configured from the Unisight DVR Server The Sound File will play locally on the speakers connected to the server A standard Windows Open dialog box will appear to select the sound file 91 Unisight DVR System LINISIGHT Homepage Hart Submit Preveiw setup Remote Setup Recording setup Alarm device Motion detect setup Alarm action Motion sain Rc O coon oh coe ig EE El PTZ setup Matrix setup Other device Network setup Advanced setup zz Customization Motion response Channel Channel Channel Channel Clear Fig 9 23 Error Setup The Error Setup page allows you to configure the Error Response Fig 9 25 The Error Response allows you to set a Sound File and Hint Message for an error condition Fig 9 24 Error response Sound file Clear Fig 9 24 92 Unisight DVR System INISIGHT LI ee Preveiw setup Recording setup Alarm device Motion detect setup WE error setup Alarm action PTZ setup Matrix setup Other device Network setup Advanced setup amp Customization Fig 9 25 MSI Homepage Back Submit Preweiw setup Remote setup Recording setup gt Alarm device Motion detect setup EE Alarm and motion
24. keyboard Left click number 01 and click the Setting button The Setting button stores the PTZ orientation to the selected number Now click the Option button This will bring up the PTZ Preset Point Info dialog box Fig 4 4 To have this PTZ preset position be a cruise point check the Act As A Cruise Point check box To have the PTZ camera pause at this point during cruising enter in a number for the Staying Time field The Description field allows you to assign a name to the cruise point The Clear button will clear the PTZ cruise point These cruise points are also stored on the PTZ camera itself and cannot be cleared by the Unisight DVR Server application To initiate the PTZ Cruising feature click the Cruise button Each time the Unisight DVR Server application is closed PTZ cruising is stopped PTZ preset position control Cruise Staying s Description Cruise 2 Tech Station Cruise Assembly Bench E Cruise 3 Cage 5 Cruise Floor Cruise Fig 4 3 PTZ preset point info vw Act as a cruise point Staying time H second Description Assembly Bench Cancel 47 Unisight DVR System Text Chat F5 This button will bring up the Chat Room dialog box Fig 4 5 To configure a chat room click the Setting button The Chat Setting dialog box will appear Fig 4 6 2 4 Chat room Server Chat room Y Hide Clear all Fig 4 5 Chat setting Technician Color gt Address Description 127 0 0 1 A
25. pop up the server side configured E Map The Playback button will switch to the Playback mode p 54 The Setup button will open the Setup dialog box where you can configure the Client application settings p 65 The Remote Control button will allow for remote administration and remote control of the Unisight DVR Server using the Client application p 78 es Fg ER par Le fo am Remote control W Connect Disconnect Record SS Lock Hide Exi EEE PLAYBACK PTZ Fig 7 8 67 Unisight DVR System Extra Button The Extra Function dialog box lists keyboard shortcuts for various features Fig 7 9 The Mute button will toggle the audio The Suspend Alarm Actions button will bring up the Suspend Alarm Actions dialog box Fig 7 10 Select the time period that the alarm will be temporarily disabled using the Duration drop down box in minutes The Hide button will hide the Unisight Client application The Cancel button will close the Extra Function dialog box Extra function V1 7 0 716HKC Mute Suspend alarm actions Ctri 3 Hide Cancel Function index _ Fi Extra functions FF Control remote host machine F2 Snapshot Fe Start a voice chat F 3 Snapshot viewer FS FA PTZ preset position F10 FS Text chat F11 Video parameters Fe Audio volume F12 Disconnect all Ctri 2 Running E Map Ctrl P Adjust PTZ speed Ctri E Channel extend into Fig 7 9 Suspend alarm actions Ctrl Duration Min Disc
26. the PTZ button The panel will change to the PTZ controls Fig 5 0 Fig 5 0 Use the arrows to pan and tilt The and buttons will focus open close the iris and zoom in and out There are also 3 function buttons that are manufacturer specific features that may not be available on all PTZ cameras ex turn on heater or wipe glass To exit the PTZ camera control mode click the PTZ button on the top of the controls 53 Unisight DVR System Playback Mode The Playback mode allows you to review recorded video Fig 6 0 You can play back a maximum of 16 channels at once You can fast forward at 16x Take note that playback at 16x on all 16 channels would be the same as playing back 256 channels at normal speed Playback at 4x on all 16 channels would be the same as playing back 64 channels at normal speed The system used for playback may not have the processing power to play back that many channels at once or at that speed of playback Be sure to monitor your CPU Usage in the DVR Information Window when playing back recorded video files DIGITAL VIDEO SURVEILLANCE SYSTEM 10 22 2007 09 48 22 CPU Usage 4 Channel 04 List Trdda Record time 10 19 2007 11 36 39 Volume 10 Speed Mormal Remote EA EN VITE IET Dee spent L ELE A SSS Se SE ER NE RR St SE m d EE f en ET TE TEE SES em LS oe re A AE ET IERE a Se Fe Sg M y ra F RECOPQING pe shll y HAEA RAEE
27. time Disk number Channel Number MB 128 4096 Minimal disk space Auto ovensrite Disk switching alert Fig 9 14 The Video Scheme page allows you to set the individual recording setup options for each video channel Fig 9 15 You can set up to three different schemes To select a different video channel left click the name of the channel and it will highlight The Video and Video Audio radio buttons allow you to record just video or video with associated audio channels The VBR Enabled check box overrides the user settings for video quality In high motion situations the bit rate will rise in low motion situations the bit rate will fall The Limit Bit Rate check box will set a maximum bit rate for VBR to prevent a large video recording file from being created during constant high motion The Resolution drop down box sets the recording resolution for the currently selected channel Not all supported capture cards support all of the resolution modes The Frame Rate FPS drop down box will allow you to set the frame rate from 1fps to 30fps The Compression drop down box will allow you to set the level of compression for the recorded video files The lower the compression number the 87 Unisight DVR System smaller the recorded video file will be This will allow more days of recording but at the cost of lower visual quality during playback The Change On Alarm check box will automatically switch the Video Scheme to the configured se
28. up The more recorded video there is stored on the DVR server the longer this process will take Use the New Password Retype fields to input the domain password if the Unisight DVR Server is connected to a network running a domain controller Environment System startup de w Auto administrator login when Windows is started w Auto startup this program D Auto reindex recording files Confirm password Reset Fig 9 47 Hi Quality playback Messenger service Audio perview Voice chat Status info Instant playback Log info keeping period Auto restart Auto shutdown Auto start Snapshot path En days 1 999 O O E BE mi D Snapshot Data Fig 9 48 104 Unisight DVR System The Environment page contains several environment options that determine the availability of certain features Fig 9 48 The High Quality Playback check box toggles the playback of unaltered video When High Quality Playback is disabled you will see a lower quality video in the Playback mode but you will use less system resources The Messenger Service toggles the Messenger Service popup window When enabled a small dialog box will popup on the DVR Server for each event that occurs such as a video loss event The Audio Preview check box toggles the audio in the Live Preview mode The Voice Chat check box enables disables the voice chat feature Voice Chat must be enabled on both the client a
29. 0 REGU ON MAP asse ASe EE Ie EES EE N EE DE ee SE 3 DEMS OF MODE ai E E 31 Guard Schedule TAD EE oh xiii EE 33 IE EAE 113 ies tas A 34 A anced Oakes seta io SR EG N E Re GO Toe dei 36 VEC COU Standard AAA 36 Unisight DVR System Recordin SEP ENEE 36 A N N N OE N N EO ie 37 ER 37 MESNE EEN 37 AL Kee EE OE Sei EE Ee 3 Channel DTIU OEE RE CTE pepsi 37 EE EE Fe eg eee re 38 TASTE AA oe Ad O O ee 39 IMPOFUEXDO CON ii A 40 EV ONM ON EE 4 Network POTS Dee ce 42 Ee AE ME N EE ET EE OR 42 Ee 42 EE 45 EE eeh 45 SIGS OG EE EE IS DOE GE DE ace ot RE 45 NIPONA roo 45 PTEPRES Clr Ee 47 TORU Chal Ee BEDE ree sea Eder ee DA GE 48 AUGIO VOM Caos recorrida 49 EE 49 SWHCH Video hamels EE AE AE EA Ee DEE We Ra A 49 All Channels Start Recordinug 0 ccc ccc ccc ccc ccna 49 All C hannels EE 49 AUS EL TAS PEL 49 Force TOS Recording Eege 50 Matie CONO as sat dane manent de Liceos wes 50 External COMMONG EE 51 EE 51 Remote Connection Canal 51 ir EEN 52 Activate Motion Detection For AU 52 Deactivate Motion Detection For Ai 52 Channel Extend INJO EE 52 keindex Record EE 52 PIZ BUON A A 53 Playback MOTE A 54 Playback Information Hued 55 Channel GEIG lt A a di Go 55 AIRE ARANA N 55 BEE 55 ST EE 56 EE El 56 Unisight DVR System Prevos E 57 DO FESE SPOOR t 57 SEP DOCK WANG SAA A 57 EE SI PU rad redada 57 a EE EE EE se tere E AEEA aN SEP T OL EE SEI E EE 57 NT EE 57 oe ME O 57 GE 57 CDAS NE EE EE 57 SMa SOME ea Y 57
30. 10 25 08 36 35 2007 10 23 08 37 19 KEE 2007 10 23 DEI ed 2007 10 25 OES ad Clear 00 10 43 00 30 50 2007 10 23 00 30 56 00 10 43 00 40 54 00 10 43 00 40 51 2007 10 25 00 41 42 2007 10 25 00 44 30 007 10 23 0842145 2007 10 25 00 43 12 00 7 10 25 00 40 14 2007 10 23 00 40 30 El OT 1 AA Oa ad ANT 1 RA DIE d 1 Backup Exit Fig 6 8 Sensitivity 1 1005 i mess 5 Switch Delete To start a Smart Search click the Setup button The Setup dialog box will appear Fig 6 9 Select the video channel you want to search through using the Channel drop down box Next fill out the Start Time by selecting a start date with the drop down box and a start time using the time field Then fill out the End Time by selecting an end date with the drop down box and an end time using the time field After you have selected your searching range click the Ok button The Setup dialog box will disappear and you will now see a video feed playing in the Search Window You can change the recorded video file playing in the Search Window using the Previous Recorded Video File and Next Recorded Video File buttons Fig 6 10 58 Unisight DVR System EE Setup Channel Mode Channel Continue Start time 2007 10 23 ei 8 00 00 4 End time 2007 10 23 2 14 00 00 F Fig 6 9 WW Fig 6 10 You can now create one or more motion zones each with individual sensitivity settings to sear
31. 11 VWideo 12 Wideo 12 Sensor 01 gt enzor 04 sensor 03 gt enzor 04 sensor 05 gt enzor 0b sensor 07 SENEOF DG senzor 09 Senzor 10 Sensor 1 1 sensor 12 Tanon 17 Fig 3 13 28 Unisight DVR System You can configure several different maps Select desired map in the the Map drop down box Click the Open button yellow open folder to select your Map File Then fill in the Description Server Address and Server Message Port You can associate the E Map with a Video Sensor or Alarm Output trigger Simply left click the desired Video Sensor or Output To select multiple triggers hold the Ctrl key and left click on them There are 3 icons that represent each type of E Map trigger Video Fig 3 14 Sensor Fig 3 15 and Alarm Output Fig 3 16 You can left click and drag each icon to the location of the actual device that the icon represents Fig 3 14 D Fig 3 15 a Fig 3 16 After an alarm or motion event occurs you can take a Snapshot To configure the time at which this Snapshot is taken enter in the desired delay in the Snapshot Delay field value in milliseconds After an alarm or motion event occurs the alarm recording or motion recording will continue during the time you define in the Recording Duration field value in seconds You can set the duration of the alarm by entering in a number in the Alarm Duration field value in seconds Short Message tab requires a GSM enabled mod
32. 2 Record p 74 Advanced p 75 and Environment p 77 Ef Setup x Connection Record Advanced Environment Server list Loopback A Server setup gt Enabled Channel Group Alarm voice Group setup Description Modify gt Select all Clear Fig 7 15 71 Unisight DVR System Connection Tab Fig 7 15 The Connection tab is where the remote client connections are configured Select the desired server from the Server List drop down box Each configured video channel for the selected server will be displayed To enable or disable the video channel check or uncheck the Enabled check box next to the video channel To disable all video channels click the Clear button To enable all video channels click the Select All button To configure each video channel left click on the Channel and 1t will highlight blue Click the Modify button to open the Network Connect Info dialog box Fig 7 16 To specify an audible sound to play on the client when an alarm condition is triggered click the yellow open folder next to the Alarm Voice field The standard Windows open dialog box will appear Browse to the desired folder and select the sound file To assign the selected video channel to a group use the Group drop down box Use the Description field to change the name of the video channel Network connect info Alarm voice ry GOLUR Description Cancel Fig 7 16 Left click the Server Setup button to open th
33. 9 66 F AHi se Lo ha E EIS dle e p Fig 9 67 11 NM Unisight DVR System Snapshot The Snapshot button will take a picture of the currently selected video channel Once clicked the Snapshot dialog box will appear Fig 9 68 The Snapshot dialog box allows you to preview the snapshot before saving it to disk Click the Save button if you wish to save the snapshot The standard Windows Save As dialog box will appear where you can choose the location and name of the saved snapshot If you do not want to save the snapshot click the Cancel button aS Snapshot Ea BE S E aer 0070609 111107 01 1 JP6 Cancel Fig 9 68 Start Recording The Start Recording button will start recording the currently selected video channel Once the recording starts you will be prompted for a location to save the recorded video files When you are recording the Start Recording button will flash To stop recording left click the Start Recording button Remote Download The Remote Download button brings up the Search Remote Recording File dialog box Fig 9 69 Use the Date drop down box to select the desired date Use the Channel drop down box to select the desired video channel With the Mode drop down box you can select what type of video recording to list You can select All Continuous Motion Alarm Manual and Network video recordings A list of all video recordings will be displayed They are listed as time index
34. Connect Button The Connect button will bring up the Connect Server dialog box Fig 7 14 Use the Server drop down box to select the desired server to connect to or use the Group drop down box to select the desired group to connect to Fill in the Username and Password fields with the right user info Left click on each video channel that you want to connect to You can also use the Select All button to quickly highlight all video channels Check the Record At The Same Time check box to start local recording of the connected video channels The Disconnect Lower Level check box 1s used to automatically disconnect any user with a lower authority level if a user with a higher authority level tries to connect to the same video channel This feature will utilize less bandwidth Once the desired video channels are highlighted click the Ok button to connect to those video channels Up to 64 remote channels can be connected to at one time The Cancel button closes the Connect Server dialog box 70 Unisight DVR System Le Kr Connect server server Loopback Group lt All gt Loopback Channel 01 Loopback Channel U2 Loopback Channel O3 Loopback Channel 04 Username Supervisor Password HRRRARAARE vw Record at the same time Screen mode Disconnect lover level select all Cancel Fig 7 14 Setup Button The Setup button will open the Setup dialog box Fig 7 15 The client setup 1s divided into 4 tabs Connection p 7
35. FIEL Se ee 13 K H Beth a i ME E HEN l ARIAS i oe 4 L Ee Seed See mer Ee N ern sites HEER OIE EN es EE LIE EIE Ges En Ces D e ei E ite Drm L ee SiS E Lamera AAA EH CHA 04 54 Unisight DVR System Playback Information Window 10 22 2007 09 48 22 CPU Usage d Fig 6 1 The Playback Information Window Fig 6 1 displays the current date time and CPU usage in white on the top of the display The channel number video file size in Mb video file length in seconds bandwidth in Mbps video file start time volume level playback speed and current playing time in green Channel Grid The channel grid contains the playback video This is where you will see all of your video recordings You can select each channel by left clicking the mouse on the desired square this will also activate the audio for that channel There is a full screen mode that you can toggle by clicking the right mouse button Grid Layout The arrangement of the Channel Grid is easily configured by 10 buttons Fig 6 2 Hover your mouse cursor over these buttons for a description of each of the layout buttons You can also zoom in and out by using the magnifying glasses Once zoomed in place your cursor over the edge of the video channel and left click to pan across the video channel Ree Fig 6 2 Calendar The calendar displays days that have recorded video footage in red days with no video
36. Fig 9 12 Recording Setup The Recording Setup page contains the Recording Setup p 86 Video Scheme p 87 Video Scheme Schedule p 88 and the Continuous Schedule p 88 Fig 9 13 The Recording Setup page contains several configuration options that apply to all video recording channels Fig 9 14 The Single File Recording Time drop down box allows you to set the maximum number of minutes a single recorded video file spans If the recording time exceeds this value a new recorded video file is automatically created The Auto Overwrite check box will automatically overwrite the oldest recorded video files when the video storage drive s are full when enabled The Disk Switching Alert check box will popup a dialog box notifying you when the Unisight DVR Server switches video storage drives The Minimal Disk Space field specifies the amount of free space needed to record video to a drive Unisight DVR System Remote setup ere ore ST LINISIGHT E Homepage si Submit Preveiw setup Remote setup Recording setup Alarm device Motion detect setup Error setup Recording setup 0 A EEEa A aera aaa Soran Ge de El N EE O ME EE OE Ee Hea ee po ep ae ek ar ag Beat al PTZ setup ER SERE GE EE GE EMM ee Ke e ee O OO er Mal vent ee VM El Matrix setup Contimicns ei MEE EE EE EE ee es El Other device Network setup Advanced setup E FF OF FO OF Customization Fig 9 13 Recording setup Single file recording
37. HA 03 CH 04 Continuous mode schedule Day Time period Sunday 00 00 23 59 Monday 00 00 23 59 Tuesday 00 00 23 59 wednesday 00 00 23 59 Thursday 00 00 23 59 Friday 00 00 23 59 Saturday 00 00 23 59 Holiday 00 00 23 59 Copy to Modify Clear w Activate schedule Server name techstation Time schedule gt Holiday Import contig Export contig Log gt User gt gt E Map gt Cancel Fig 3 3 Pressing the Clear button will clear the schedule for the currently selected schedule tab The Activate Schedule check box toggles each schedule on and off for each selected video feed in the Channel List The Modify button will bring up the Set up Time Schedule dialog box and will allow for 16 different time schemes to be applied Fig 3 4 22 Unisight DVR System Setup time schedule Time period scheme Time periaci 1 Time perio Hl Tef E Time period Hl ml TE Time besaat 1 To Time perio E TeL H Time period Hl Jef E Time period 1 ET 7 To Time periods Po To Copy to w Monday Tuesday w Wednesday w Thursday w Friday Saturday w Holiday Select all Invert Cancel Fig 3 4 The Time Period drop down box will allow you to apply any of the 16 different time schemes To apply the time scheme to any day simply check the box next to the day Use the Select All button to quickly check all days including Holiday Use the Invert button
38. Motion 2007 10 23 10 07 56 205 2007 10 23 10 08 17 Motion 2007 10 23 10 18 58 125 2007 10 23 10 19 11 Motion 2007 10 23 10 02 17 As 2007 10 23 10 02 50 Motion Select all Inverse select all files Inverse Total files 66 Selected files 0 Backup gt Cancel Fig 6 19 Use the Date drop down box to set a date range to filter the results Use the Time fields to set a start and end time range to filter the results Ensure that the Start Time 1s before the End Time 1f 1t 1s not no recorded video files will f1t that criteria and there will be no results when searching The Recording Type drop down box will allow you to further filter the results by searching for only Motion Manual Continuous Network Alarm based recordings To search through multiple cameras check the box next to the channel name The Select All button will automatically check all Cameras The Inverse button will select the exact opposite of the currently selected cameras Click the Search button to begin the recorded video file search In the results the Start Stop Time Length Channel Mode and Disk will be displayed Left click a video file to select it Hold down the ctrl key and left click to select multiple recorded video files to backup The Select All Files button will select all results The Inverse button will select the exact opposite of the currently selected video files The Cancel button will exit the Backup Recording Files dialog box When you have selected the d
39. Period fields to define the time periods for the scheme To save the new scheme left click the Save button The Clear button will remove all time periods from the selected scheme The Holiday Setup allows you to associate specific dates to the Holiday when configuring the scheduling options Fig 9 51 Use the calendar to select the desired date To add it to the Holiday list click the left arrow To remove a date from the Holiday list select the desired date and click the Delete button To clear the entire Holiday list click the Clear button 106 Unisight DVR System Holiday setup Holiday 1 30 Select date 4 Oct 2007 F 5 M WW T F 5 BI Pd LA Te en 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 En Delete Clear Fig 9 51 The Customization page allows you create a custom menu for quicker operation Click the Customization Setup button to open the Customization page Fig 9 52 Use either list to select a menu option Use the left and right arrows to add remove items Customization ected 15 16 Optional 21 36 Video scheme schedule Video parameter Sensor relation to output Color scheme Recording setup Color scheme schedule Sensor relation to channel Sensor info setup Continuous schedule Output info setup Channel relation to snapshot Motion schedule Device type Motion response Watchdog Error response PSTN setting gt Alarm and motion detection Keyboard Video schem
40. Record button is pressed Fig 3 1 The Allow Network Access checkbox toggles the ability for remote clients to connect to the Unisight DVR Server Server Name The Server Name identifies the Unisight DVR Server By default this name is taken from the Computer Name that is configured in Microsoft Windows XP 2000 Memo E Memor Memor Memor Memo 3 Memo 4 Memor Memor Memo 7 Memor Memo 8 Memor 0 Memor 2 Memor 3 Memor 4 Memoli 5 Memali 6 Memoli Memali 3 Memali 3 Memor 20 Fig 3 1 20 Unisight DVR System Color Motion Tab Fig 3 2 Ef Setup Ka Channel list Camera ColorMotion Schedule Alarm actions Relation Guard schedule PTZ Advanced Environment PTZ Color scheme CH O2 CH IO CH O Switch Delete Clear all Sensitivity 5 Copy to E Mask area Server Name techstation Brightness Contrast Saturation Hue Schemeti b 55 7 ES EO 1 a Detant Import config Export config gt Fig 3 2 The Color Motion tab can be used to setup the motion detection areas and the video signal parameters such as brightness contrast saturation and hue for each individual video channel Multiple motion detection zones can be configured for each selected camera A different motion sensitivity can be set for each of these zones To create a motion detection zone left click and drag a box around the desired area and set the desired se
41. SMS will be sent to The Description field is the text that will be sent Be sure to check the Enable Action check box Match the COM Port settings to that of your GSM modem The Clear button will erase all settings 95 Unisight DVR System Short message setting SMS Center Mumb Descriptio C KZ BE AAA E GE Enable action Clear COM port PSTN setting Fig 9 30 Number D ption E A E EAR DG KAN Ee Fig 9 31 96 Unisight DVR System The PSTN page allows you to setup a telephone number to be dialed when the Unisight DVR Server detects an alarm condition Fig 9 31 An additional modem must be installed and configured for this feature to work Use the Number field to input a telephone number Do not put parenthesis or hyphens The area code is required if you are calling out of the home area that the server 1s in Use the Description field to input a description Be sure to check the Enable Action check box The Clear button will erase all configured Numbers and Descriptions The E Mail Setting page configures the e mail on alarm feature Fig 9 32 E mail setting E mail address Description goz Fe ee CI MEN ee CA EN II EN pe AAA w Enable action Clear Internet account A Sender Head Of Security w My SMTF server need checking authorization Sender address security unisight net Username SMTP server smtp unisight net Password Fig 9 32 Type in the
42. TZ camera will be displayed Use the Current PTZ Protocol drop down box to select your supported PTZ camera Match the COM Baud Rate Parity Address Index Data Bit and Stop Bit to the settings of the PTZ camera The Fast Response To Remote Control check box will drop the currently queued frames for the client and send the last frame This speeds up PTZ response on the client side Use the Up Down Left and Right arrows to move the PTZ camera The Function buttons will activate manufacturer specific features that may not be available on all PTZ cameras ex lens wipe There are also controls for focusing iris control and zooming to test the PTZ camera to ensure functionality The Clear button will erase all configured settings for the currently selected video channel 98 Unisight DVR System Homepage Hack Submit Preveiw setup Recording etup Alarm device Motion detect setup Alarm action Sensor relation to preset point s be ee rr rr ee eB ke PTZ setup Matrix setup Other device Network setup Advanced setup amp Customization Fig 9 35 Current PTZ protocol PELCO D be Clear Channel list COM Baud rate 9600 Data bit O E IE zi 2 O LJ Parity None Stop bit Address index Dy Fast response to remote control E S 3 2 a ale Ki O a e se s Fig 9 36 99 Unisight DVR System The Sensor Relation To Preset Point page allow
43. Unisight DVR System Unisight DVR Manual Ver2 7 1027 revl 3 d Fre goav O wal DIGITAL VIDEO RECORDING SURVEILLANCE SYSTEM COPYRIGHT 2006 UNISIGHT DIGITAL TECHNOLOGIES INC Website www unisight net Email sales iunisight net Unisight DVR System Table of Contents System Requirements 0 0 ccc ccc ccc ee ee ee ee ee ee ee ee ee ee ee 8 URISTONE DER SEEP tt a 8 Server Hardware Requirements 0c cc cece ees ees ee ee ee ee ee ee seed 8 Server Software Reguirement se See ee ee ee ee ee dee ee 8 Client Hardware ReQuireMents ccc ccc ccc ec ccc ee ee ee ee ee see 8 Client Software Reguirement cc ccc ccc cece cee ee ee ee ee ee ee 8 TASA lt A d 9 lastall DYR SO WTC Ab 9 stal DER TIENE ci EG GE Se Ee EE ei a Sata dawn 12 DERS ai ET EO EE RE EE ED 13 EK Yi iia 13 Main DVR STC Nardi 14 DVR Information Minden 15 CAMEL AUS LEDS iaa 15 Channel Gr A roa ASIN Sa 15 GAL LOVOM Ee elen 16 PIY R Conto OO Ee A aN 17 Locking Unlocking and kung 18 NAAA EE 19 AT A O 19 CONTADA a N 20 MED Ee A ads E NE PEETA E TE ee 20 COLOR MONO LAD iS A ed dee ees 21 Schedule AD ODE EE EE AEN is sere gk 22 NAAS N OR DT RR EEA 23 ate Mee RE OR EE EO eee 24 Alr MACHONS LOD RES EE RE EG vot GE GE neues 25 COMET ATION IY EE aa 25 DEVICE SC CCH ON SESSE GES EE EE SG EE EE GE EE OGE EE 25 Alar RESPONSE add GP 27 EMO SAA AAA 28 SOME ed Aube 29 POLN A 29 e 3
44. VR main screen Fig 7 2 This screen contains the DVR Information Window p 65 Camera Status LEDs p 67 Channel Grid p 65 Grid Layout buttons p 66 and the DVR Control Buttons p 67 Installation 4 Login DVR Client Ej Username SUpervizor Password Cancel Fig 7 0 Channel Grid The channel grid contains the remote video preview This is where you will see all of your connected video feeds You can select each channel by left clicking the mouse to activate the remote audio preview for that channel To maximize a video channel double click it To restore the Channel Grid double click the video feed again There is also a full screen mode that you can toggle by clicking the right mouse button on any video channel DVR Information Window The current date and time are displayed here along with the CPU workload The available hard disk drive space is also displayed here Fig 7 1 10 22 2007 10 27 47 CPU Usage 2 Free spacer hy 61746 Fig 7 1 65 Unisight DVR System 10 29 18 CPU Usage D Free space thi 61746 Desea ROR SETUP PLAYBACK PTZ aa Record C Lock Grid Layout Buttons The arrangement of the Channel Grid is easily configured by 12 buttons Fig 7 4 Hover your mouse cursor over these buttons for a description of each of the layout buttons The Auto Group Switching button will cycle through each configured group Fig 7 3 The Disconnect All butto
45. ach channel by clicking the Extend Info button Fig 3 29 Channel description Camera description Extend info gt gt Fig 3 28 37 Unisight DVR System Channel extend info Fig 3 29 To configure the storage drives click the Disk Group Setup button Fig 3 30 Select a disk group from the Group drop down box All available drives will be displayed Check the box next to each drive to add it to the disk group You can assign different disk groups to different video channels p 16 Disk group setting Group Group Storing days Disk Disk spacelM Free space He 78152 52213 Cancel Fig 3 30 38 Unisight DVR System Instant Playback The Instant Playback feature allows you to playback the cached video from memory Depending on the configuration you can view the past 20 seconds The Instant Playback checkbox must be checked to enable this feature Once enabled select the desired video channel and left click the Extra button Then click on F7 Instant Playback Alternatively you can select the desired video channel and press F7 on the keyboard The Instant Playback dialog box will appear Fig 3 31 You can Play Fig 3 32 Pause Fig 3 33 and Stop Fig 3 34 the video using the appropriate buttons To play the video in fullscreen mode click the Fullscreen button Fig 3 35 To increase or decrease the playback speed use the Play Slower Fig 3 36 or Play Faster Fig 3
46. al speed 0 1 00 100 Vertical speedr0 1 00 100 Fig 4 8 49 Unisight DVR System Force To Switch Recording File Ctrl C This button will create a new recording file for each video channel even if the Single File Recording Time p 36 has not been reached Matrix Control F8 This button opens up the Matrix Switch dialog box Fig 4 9 Matrix switch Public view Public view DH e Enable auto switching Link Shavings Description Show Video 0 Video 0 Video 2 Video d ideo 05 Video Video 07 Video 05 Video 09 Video 10 Video ll Video 1 Video 132 Video 14 Video 1 Video l Fig 4 9 This feature requires an MD card To configure the logical monitor grid layout you must edit the _TCStartup ini file first Fig 4 10 This file is located inside the Server application directory ir _TCStartup ini Notepad Jag Fie Edit Format wiew Help LMetPorts TOV MSEG PORTAOOO TOM TIMEADIUST_PORT 80071 signal WT SC 1 Timesdjust Enabled 0 serveraddress Hardware Decodecard_PlayBack 0 Matrix Reqions L 1 1 1 1 1 1 1 Decodecard_Ccl1ent 0 Fig 4 10 S Unisight DVR System The line labeled Matrix Regions contains the configuration information The first number corresponds to the first physical monitor connected the second number corresponds to the second physical monitor connected These numbers specify the logical monitor grid layout Supported layouts a
47. all related outputs use the Clear button The Standard Mode button will assign sensor 01 to output 01 sensor 02 to output 02 and so forth The Sensor Relation To Channel page allows you to link sensors to trigger Alarm Recordings Fig 9 21 Start by selecting the sensor by left clicking The selected sensor will highlight green Left click the desired channel and click the left arrow to add it to the list To remove an added video channel use the right arrow To clear all related video channels use the Clear button The Standard Mode button will assign sensor 01 to ch 01 sensor 02 to ch 02 and so forth Each recorded video file triggered by an external sensor will be listed under the Alarm type when using the Playback mode The Guard Schedule is similar to the Color Scheme Schedule p 84 Sensor relation to channel Standard mode Clear Channel list ID Description Sensor 01 relation to channels 2 Sensor 02 CH 03 3 Sensor 03 ad CH 04 4 Sensor 04 a Sensor Os 6 Sensor 06 7 Sensor OF 8 Sensor 08 Ka 2 sensor UD ES 10 Sensor LU 11 Sensor 11 12 Sensor 12 13 Sensor 13 14 Sensor 14 13 Sensor 15 Fig 9 21 Motion Detect Setup This page contains the Motion Schedule p 91 and the Motion Response p 91 pages Fig 9 22 The Motion Schedule page is similar to the Color Scheme Schedule page p 84 The Motion Response page allows you to assign a Sound File and Hint Message to each
48. arrangement of the Channel Grid 1s easily configured by 12 buttons Fig 2 5 Hover your mouse cursor over these buttons for a description of each of the layout buttons 10 EB ER ER HEH ER EE ES IK Fig 2 5 The Reset Screen Status button allows you quickly set the Channel Grid to the original layout This will allow you to set a grid configuration layout of more that 16 for higher channel Unisight DVR servers Fig 2 6 Fig 2 6 If you choose to display one video channel at a time you may automatically cycle through all connected video feeds The Screen Auto Switching button enables this feature Fig 2 7 Fig 2 7 Once you click the Screen Auto Switching button the Setting Switch Interval dialog box appears Here you are able to start and stop the screen switching You can also set the time interval at which the screens will switch Fig 2 8 Setting switch interval Time interval vw Roll switch mode 16 Unisight DVR System DVR Control Buttons These buttons allow you to control and configure the Unisight DVR Server application Fig 2 9 and Fig 2 10 oe TIP PLAYBACK PTZ Fig 2 10 The Extra button brings up the Extra Functions dialog box p 45 The Audio button toggles the live audio preview A highlighted button indicates that live preview audio is currently enabled The Record button toggles manual recording for the currently selected video channel The Motion button toggles mo
49. ch through the recorded video files The currently selected motion zone will be highlighted white the rest will be red To cycle through the motion zones use the Switch button To remove the currently selected motion zone click the Delete button To clear all motion zones click the Clear button Left click and drag a motion zone around the desired area A white square will appear Set the sensitivity for the motion zone s and click the Search button a progress bar will appear to display the search progress While the search 1s being executed you can temporarily pause by clicking the Pause button To resume the search click the Continue button Once the search has been completed the video results will be displayed To play a recorded video file highlight the desired file and left click the Play button You can also Pause and Stop the video Click the Snapshot button to take a snapshot of the entire video frame p 45 To backup any of the recorded video files select each recorded video files by left clicking on them To selected multiple recorded video files hold down the ctrl key and left click on multiple recorded video files Once you have made your selection click the Backup button p 62 You can save a Smart Search and review it at a later time Click the Bookmark button to open the Bookmark dialog box Fig 6 11 Input the name of your saved search in the Bookmark field You can also type in a description of the saved search in the Description
50. config Channel description Disk group setup Export contig gt User Cancel Fig 3 26 36 Unisight DVR System Others The High Quality Playback check box toggles the playback quality The Voice Chat check box toggles the ability to use a microphone to talk between the Server and the Client The Messenger Service check box enables a Messenger Service dialog box popup This dialog box will appear at the bottom of the screen and display various messages pertaining to the Unisight DVR Server Fig 3 27 The Audio Preview check box will toggle the Live Preview Audio in the Main DVR Screen The Status Info check box toggles the display of status information on each video channel preview image Messenger service Server No Date Info 01 2007 08 07 10 39 12 PTZ command sending Failed Fig 3 27 The Watchdog drop down box should have Unisight selected Click the COM Port button The COM should be COM the baud rate should be 9600 and the Parity should be none The Matrix drop down box and associated COM Port button should already be setup The Snapshot Path is the directory where all snapshots will be stored To select a different location click the open button open yellow folder and choose the desired location To change the name of an individual video channel click the Channel Description button Fig 3 28 Simply type in a name for each channel in the Camera Description field You can add an extended description to e
51. corresponds to which input you have your sensor connected to on the alarm relay controller Input the proper number in the ID field Using the Description field you can give your sensors different names Fill out the Description field as desired Once you have your sensor setup click the Ok button to return to the Relation tab 31 Unisight DVR System Sensor property High level trigger Low level trigger Description sensor DI Fig 3 21 You can link each sensor to either a video channel or an alarm output on the alarm relay controller To setup the alarm outputs first select the output number that the alarm device is connected to on the alarm relay controller by checking the box in Link To Output Enter in a description and select either High or Low for the Trigger You can also select a High Level Pulse or a Low Level Pulse The Pulse will trigger the output for a short time and then turn off You can link several alarm outputs to a single sensor To link a sensor to a video channel select your sensor from the Sensor List Then check the box next to the desired video channel The Preset column allows you to enter in a PTZ Preset Position p 41 number that the PTZ camera will automatically face when the sensor 1s triggered The Snapshot column will allow you to save a snapshot when the sensor is triggered The Output column allows you to assign an alarm output number to trigger any alarm device connected to the alarm relay controll
52. d taction SEKER EE RR Alarm action Channel relation to output EE EER ER SEER RE ER be eee ee BN PTZ setup Channel relation ta snapsher 692 ee ere eee eee EE a ae Ver ee Es a Matrix setup Short message EE ee y be device PSTN setting RR e We cay ME ae vest KC vate Kar vee STEE vent We B Network setup GE EE EE Advanced setup Alarm response e EE E EE EE it DE EE Er H Customization Camera priority bk ere a dk eer Ee ned ey ree re esd chy peer a a ere ree o br ee e BR Fig 9 26 93 Unisight DVR System Alarm Action This page contains the Alarm And Motion Detection p 94 Channel Relation To Output p 95 Channel Relation To Snapshot p 95 Short Message Setting p 95 PSTN Setting p 97 E mail Setting p 97 Alarm Response p 97 and Camera Priority p 98 pages Fig 9 26 The Alarm And Motion Detection page configures how the Unisight DVR Server reacts to alarm motion conditions Fig 9 27 The Alarm Recording check box enables recordings triggered by alarm conditions such as motion detection The Popup E Map check box enables the E Map feature Once the E Map is setup it will popup onscreen for the security personnel to react to The Single Screen Preview will maximize any channel that has motion and will not revert back until action is taken either by double clicking the video feed or by using the grid arrangement buttons p 25 The Show Motion Area check box will toggle the display of c
53. ddress 127 0 0 1 Server port 6000 Description Tech Support Fig 4 6 48 Unisight DVR System Set a name for the chat room using the Name field Input the Address Server Port and Description using the fields at the bottom of the window Select the text color using the Color button Once configured click the Save button to return to the Chat Room dialog box To enter a chat room select the desired room using the Chat Room drop down box Type in a message in the bottom text field and press the Send button to have your message appear The Hide button will hide the Chat Room dialog box The Clear All button will clear the chat room text Audio Volume F6 This button will allow you to adjust the volume controls Fig 4 7 di 3532 Way Gout Min Fig 4 7 Instant Playback F7 This button will open up the Instant Playback dialog box p 39 Switch Video Channel Tab This button will cycle the video channel selection in the DVR main window All Channels Start Recording Ctrl R This button will start manual recording on all channels All Channels Stop Recording Ctrl S This button will stop manual recording on all channels Adjust PTZ Speed Ctrl P This button will allow you to change the speed at which the PTZ moves Pressing Ctrl P will bring up the Adjust PTZ Speed dialog box Fig 4 8 This will not change the speed at which the PTZ camera moves when the PTZ camera is Cruising Adjust PTZ speed Horizont
54. de will stream the video from the recorded video file Playback will start immediately but many of the Playback Controls will be unavailable since the video 1s streaming IE Remote e Fig 6 13 d Remote SYNC playback LL Playback mode Local synchronizer search mode Y Username Password Fig 6 14 Snapshot The Snapshot button will take a still image of the currently selected video file Fig 6 15 You can then save this image for later review p 45 Fig 6 15 Browse And Print Image File The Browse and Print Image File button allows you to view previously saved snapshots and print them out Fig 6 16 p 45 61 Unisight DVR System Fig 6 16 Manual Selecting File If you have recorded video files stored in a location other than the default the video recordings will not show up in the Calendar Use the Manual Selecting File button to access the recorded video files Fig 6 17 To browse for recorded video files click the Open button open yellow folder The standard Windows browse dialog box will appear Locate the folder that the recorded video files are stored in and click the Open button You will be returned back to the Select Video File dialog box You can sort the recorded video files by channel recording type and by time index Once you locate the recorded video file you wish to play left click on it The recorded video file will highlight blue Then click the Ok button and the s
55. e Server Info dialog box Fig 7 18 Left click on one of the servers it will highlight blue Fill in the Address field with the Unisight DVR Server s IP address If you are on the local area network use the local IP for the DVR If you are connecting from a different location use the static IP assigned by your ISP Type in the number of channels that the DVR server has in the Channel Number field The Description field is used to change the name of the server on the list The Network Ports button is used to configure which port to use for the connection Fig 7 19 Fill in the port number configured on the server side p 36 in the Server Message field and click the Ok button The Disable Alarm Action check box is used to temporarily disable the alarm actions while the client is connected The Clear button will restore the defaults for that server connection The Log button will open the Log Viewer dialog box Fig 7 17 Each log file is organized by date You can sort by log entry type using the Type drop down box You can also sort log entries by user with the Username drop down box Use the Save button to backup the log file The E Map button will open the Map Setting dialog box and allow you to configure the client side electronic map p 28 72 Unisight DVR System Description 08 08 2007 08 56 12 Supervisor start system 08 08 2007 08 47 36 Supervisor close system Exit system 08 08 2007 08 47 02 Supervisor start system pe lt All
56. e Short message setting Camera priority E mail setting PTZ Alarm response Guard schedule Sensor relation to preset point Network schedule Matrix Sensor relation to matrix input Fig 9 52 107 Unisight DVR System User Manager Fig 9 53 The User Manager page will display all configured users To delete the currently selected user left click the Delete User button You cannot delete the Supervisor account Add user Delete user Modify userinfo g Assign authority Camera access Username Level Status Full name Description Supervisor Admin Active Default user Admin Administer the system ES N Net2 Advanced Active Network 21 Network access user 2 Netz Medium Active Network 3 Network access userl 3 Neta Low Active Network 47 Network access user Al Fig 9 53 Click the Add User button to add a user The User Info page will appear Fig 9 54 Input the username in the Username field Input a password in the Password and Verify Password fields The Password and Verify Password fields must contain the same password Optional Input the name of the user in the Full Name field Optional Input a description of the user in the Description field Select the authority level using the Level drop down box If remote viewing is all that 1s needed for the user select the Low authority level Check the Default User check box if you wan this user to be the default selected user when Locking Unlocking Exiting or Logging in to t
57. elected file will begin to play Select video file gt ES Channel sal k Type all Select all Path CABACKUP DATA Date Time Enable time titer Start time Lengthis Stop time Size Channel Bandwith Mode 06 07 2007 09 00 19 12s 08 07 2007 09 00 52 Falk 04 0 40 Motion 06 07 2007 09 08 13 155 06 07 2007 09 00 32 a E 04 0 24 Motion Standard mode Cancel Fig 6 17 Backup Files The Backup Files button Fig 6 18 will open the Backup Recording Data dialog box Fig 6 19 From here you are able to backup multiple cameras simultaneously During the last part of the backup the player software is automatically copied over along with the recorded video files No other software 1s need to review the saved video Fig 6 18 62 Unisight DVR System VY Backup recording data Recording type Alle Date 2007 10 25 2007 10 23 e Time 10 00 00 4 11 00 00 E Camera Start time Lengthis Stop time Channel Mode H PT 2007 10 23 10 00 05 Lis 2007 10 23 10 00 23 S Motion cn 2007 10 23 10 01 53 165 2007 10 23 10 02 10 F Motion lc 2007 10 23 10 01 53 EES 2007 10 23 10 02 16 Motion CHA 04 2007 10 23 10 03 11 245 2007 10 23 10 03 36 Motion 2007 10 23 10 02 51 d4s 2007 10 23 10 03 36 Motion 2007 10 23 10 04 02 s 2007 10 23 10 04 59 Motion 2007 10 23 10 05 25 18s 2007 10 23 10 05 44 Motion 2007 10 23 10 07 26 185 2007 10 23 10 07 45 Motion 2007 10 23 10 07 47 115 2007 10 23 10 07 59
58. em and may not be available in all areas The PSTN tab allows you to configure a phone number that the Unisight DVR Server will dial when there is an alarm action Fig 3 17 Input the desired phone number in the Number field and assign a description in the Description field This feature requires active phone service and an installed configured modem To activate this feature check the Enable Action check box Short message PSTN E Mail Description 349 521 6431 Head of Security Enable action w i Clear all Fig 3 17 29 Unisight DVR System The Unisight DVR Server has the capability to e mail an alert to any address for alarm events Select the E Mail tab to configure this option Fig 3 18 For each e mail address that will receive these e mail notifications you need to enter it in to the E Mail Address field You can also enter in a description to associate with them To setup the sender s e mail click the Internet Accounts button The Internet Account dialog box will appear Fig 3 19 Fill out each field This is the e mail address from which the notifications are sent from To activate this feature after you have properly configured each item check the Enable Action check box Short message PSTN E Mail a E Mail address Description A Internet accourts O1 Enable action CO Ol Gy CH cn co Pi w Clear all gt Fig 3 18 Internet account Sender Sender address SMTP server
59. er The Matrix In column will display the video channel number on Public View 01 p 44 that you enter 32 Unisight DVR System Guard Schedule Tab Fig 3 22 The Guard Schedule Tab is where you configure the schedule for each sensor connected to the alarm relay controller Refer to the Schedule Tab section for setup p 18 S Setup Channel list Camera ColorMotion Schedule Alarm actions Relation Guard schedule pTZ Advanced Environment sensor 01 Sensor 02 sensor 03 sensor 04 Sensor 05 Sunday 00 00 23 59 Sensor DE Monday 00 00 23 59 Sensor 07 Tuesday 00 00 23 59 Senzor 08 wednesday 00 00 23 59 Senzor 09 Thursday 00 00 23 59 Sensor 10 Friday 00 00 23 59 Senzor 11 Saturday 00 00 23 59 Sensor 12 Holiday 00 00 23 59 Sensor 13 sensor 14 sensor 15 Sensor 16 Day Time period Copy to gt Modity w Activate Alarm Schedule Server name techstation Time schedule gt gt Holiday gt Import contig Export contig gt User Fig 3 22 The Time Schedule button will bring up the Setup Time Schedule window p 23 The Holiday button will bring up the Holiday Setting window p 24 33 Unisight DVR System PTZ Tab Fig 3 23 Here you can setup PTZ camera controls and any external PTZ control device E Setup E Channel list Camera ColorMotion Schedule Alarm action Relation Guard schedule PTZ Advanced Environment PTZ Current PTZ
60. er file size The Compression drop down box sets the compression level of the recorded video files A higher compression will have lower visual quality but a smaller file size Environment The Enable CPU Threshold check box will not allow you to connect to more channels once the CPU Usage has reached 100 The E Map Popup check box toggles the configured electronic map Checking this box will allow the e map to pop up The Auto Alarm Connect check box will automatically connect to any configured video channel that senses an alarm condition The Auto Remote Playback check box when checked will automatically connect to the same server you are viewing under the Live Preview mode when the Playback mode 1s entered The Voice Chat check box will enable the full duplex voice chat feature between the client and the server The Alarm Record d Unisight DVR System check box will automatically start recording a connected video channel when during an alarm condition The Auto Re connect check box will sense when a video channel has lost its connection to the server and attempt to re establish the connection The Hi quality Playback check box toggles the high quality playback feature When unchecked the video will be a lower quality but it will use less CPU resources If checked the video will not be reduced in quality but will use more CPU resources possibly maxing out the CPU usage on the client machine The Messenger Service check box will enable the messeng
61. er service on the client p 37 You can specify how many days that the client application will keep a log file before overwriting 1t by inputting the desired number of days in the Log File Keeping field To change where the snapshots are stored left click the yellow open button next to Snapshot File Path A standard Windows open dialog box will appear in which you can specify the location that you want the snapshots to be stored in 4 E Setup Connection Record Advanced Environment Signal setting salie Compression Normal Environment vw Enable CPU threshold vw Auto remote playback w Auto re connect w E Map popup w Voice chat w Hi gualty playback Auto alarm connect w Alarm record Messenger service Log file keeping AU Dayal 999 Snapshot file path Cosnapshot Data EJ Log gt E Map gt OM Cancel Fig 7 22 76 Unisight DVR System Environment Tab Fig 7 23 System Startup Check the Auto Administrator Login When Windows Is Started to have the client software login to Windows XP 2000 If the client machine belongs to a domain you must click the Password button and enter in your domain password Fig 7 24 Check the Auto Startup This Program to have the Unisight DVR Client application start with Windows If you have several different Unisight DVR Server video channels assigned to the same group check the No Login Dialog Box When you setup the server connection the Username and Password fields will be hi
62. es The start and stop time for each video recording file is displayed Select the desired times by left clicking on the time To select multiple video recording files hold down the Shift key and left click on several video recording files The Select All button will highlight all listed recorded video files The Clear button will clear the selection Once you have your video recording files selected they will highlight blue Click the Download button to start the download A standard Windows save dialog box will appear 113 Unisight DVR System Search remote recording file Date 08 08 2007 id Channel Cum Mode lt All gt OS 23 2300 316 09 42 20 09 4 26 09 4522 09 4329 09 4349 09 43 55 Select all Download Fig 9 69 Playback The Playback button will open up the Player application Fig 9 70 To load a recorded video file click the Open button yellow open folder A standard Windows open dialog box will appear Navigate to the recorded video file and click the Open button The playback buttons are similar to the Playback mode p 54 The Player application is also stored when you backup any video recording file from the Unisight DVR Server or Client application Video Player IEDER Fig 9 70 114 Unisight DVR System System Information Fig 9 71 The System Information page will display information about the Unisight DVR Server The Software Version CPU Memory OS and Physical Disk are inc
63. esired recorded video files click the Backup button The Files Backup Manager dialog box appears Fig 6 20 Files backup manager File backup Label RoutineBak e Backup Backup tools gt USA devices gt Fig 6 20 63 Unisight DVR System The Backup Tools button will open up Nero and allow you to add more files to the CD session The USB Devices button will allow you to remove USB devices that you do not want to show up in the Device Type drop down box when finishing the backup process Type in a name for your backup in the Label drop down box Now click the Backup button The Select Path dialog box will appear Fig 6 21 iF Select path El Device type Compact disc Drive list El Free Space DOME Space needed 5 1 MB Save Cancel Fig 6 21 Select the backup device using the Device Type drop down box If you select Compact Disc the Drive List drop down box will automatically select your CDR W drive Click the Save button to complete the backup process 64 Unisight DVR System Client Setup Client and Server applications are both included in a single package Follow the Installation instructions p 9 Initial Startup The first time the Unisight DVR Client applications 1s run a username password dialog box will appear Fig 7 0 By default the username is Supervisor and the password field 1s left blank Click the Ok button to login After logging in you will see the D
64. f time in seconds that the alarm continues to trigger The Channel Relation To Output page links motion detection to an alarm output device Fig 9 28 Channel relation to output Standard mode Clear ID Description CH 01 relation to outputs Output 2 CH OZ 4 Output 02 3 CH 03 Output 03 4 CH 04 Output 04 Output 05 Fig 9 28 First select a video channel by left clicking on the channel name It will highlight green Then select an output device by left clicking on the output device name Use the left arrow to add the output device to the list Use the right arrow to remove an output device from the list The Clear button will remove all output devices from the list The Standard Mode button will set ch 01 to output 01 ch 02 to output 02 and so forth The Channel Relation To Snapshot page allows you to automatically take a snapshot of the video feed during an alarm condition Fig 9 29 You can select each individual channel by using the check box next to the channel name The Snapshot check box will automatically apply to all channels CH O1 CH 02 CH 03 LINE L CH 04 Fig 9 29 The Short Message Setting page contains the options for sending an SMS to your phone when an alarm action is detected Fig 9 30 This feature requires a GSM enabled modem The SMS Center field is supplied by your provider The Number field is the cell phone number that the
65. field To save the search click the Ok button Bookmark K Bookmark 20071 0235 151 717 01 Description Smart Search Fig 6 11 59 Unisight DVR System To review a saved Smart Search click the History button in the Smart Search dialog box The History dialog box will appear 6 12 Select the date in which the search was bookmarked using the Date drop down box then select the name of the bookmark from the Bookmark drop down box The Delete button will remove the currently selected bookmarked smart search The Clear All button will delete all bookmarked smart searches Use the Select All button to select all recorded video results The Inverse button will change the selection to the exact opposite of the currently selected recorded video results The Delete button will remove the selected recorded video file from the bookmarked smart search You can also backup recorded video files from the History dialog box Click the Backup button to backup the selected video recording files p 62 Use the Exit button to close the Smart Search and History dialog boxes FE History LG Date 2007 1 0 09 7 Delete Clear all Bookmark Desk Search Description searched for all movement on the top o tthe desk La No Searchtime Charel Resut O oOo O N Pe 2007 10 09 13 53 52 m 2007 10 09 13 53 52 2007 10 09 13 5352 00 10 09 13 83 32 2007 10 09 13 83 32 00 10 09 13 83 22 2007 10 09 13 83 22 007 10
66. footage are displayed in black Fig 6 3 To change months use the single blue arrow To change years use the double blue arrow To quickly change to the current date left click on Today 39 Unisight DVR System Wa Calendar e File lists File List You can also search for video recordings using the File List Fig 6 4 Simply select the date from the Date drop down box and the channel name from the Cameras drop down box You will see a range of times Each time range is a single video recording file To playback a recorded video file left click on the desired time range and click the Play button We calendar RODER Date 08 43 15 06 47 50 DEER 1O OE BA 12 BEERS DEER 24 U0 00 01 Cameras 09 00 01 09 03 47 PT7 09 03 47 09 03 58 09 03 56 09 1 3 59 09 13 59 09 24 00 09 34 01 09 44 02 Fig 6 4 Playback Controls These controls will allow you to control various aspects of playback Fig 6 5 From left to right these are Previous File Decrease Speed Step Backward Stop Play Pause Step Forward Increase Speed Next File Multiplay Stop All Clip and Smart Search Smart search Fig 6 5 Volume Mute Fig 6 6 56 Unisight DVR System Previous File Jumps to the previous video file Decrease Speed Slows down the playback speed Step Backward Moves the time slider back one frame also pauses video playback Stop Stops playback on the currently selected video file Pla
67. g setup Alarm device Motion detect setup Error setup Network Setup rr El Ala SEER Network schedule ter RASSE KEER ee ee Esa bd Ree bee ebb eae BN PTZ setup Matrix setup N Other device Network setup Advanced setup Customization Fig 9 44 Enable client connection Enable local web server HTTP port E 80 Server message Fig 9 45 Homepage Esck Submit Preveiw setup Remote setup Recording setup Alarm device Motion detect setup Error setup System setup A AA Al Gta AR AAA MEET AE ANE ust le El 3 Alarm action TR die PB pace ee ee ee PTZ setup EECHER El Matte Setup Timo sibame setup EE EE e Other device Holiday setup ee El Network setup Advanced setup es ZZ SZ Customization Fig 9 46 103 Unisight DVR System Advanced Setup This page contains the System Setup p 104 Environment p 105 Channel Associated p 106 Time Scheme Setup p 106 and Holiday Setup p 106 pages Fig 9 46 The System Setup page contains several startup options Fig 9 47 The Auto Administrator Login When Windows Is Started check box automatically logs in to Windows on boot The Auto Startup This Program check box automatically starts up and locks the Unisight DVR Server application when Windows logs in The Auto Reindex Recording Files check box will automatically reindex the video recording files when the DVR Server starts
68. ghlighted Enter in the correct username and password into these fields p 70 Others The Keyboard drop down box allows you to configure a supported external device for controlling a PTZ camera p 34 Ef Setup Si Connection Record Advanced Environment System startup w Auto administrator login when Window s is started Password gt Auto startup this program Mo login dialog box Others Keyboard Cancel Fig 7 23 Confirm password Mew password 288222 Retype HRAAARRA Fig 7 24 Fe Unisight DVR System Remote Connection Fig 7 25 The Remote Connection button brings up the Control Remote Host dialog box Each configured Unisight DVR Server will appear on the left side The Show Server Address check box will toggle the display of the IP Port after the server name To refresh the list of servers click the Rediscover button The Restart button will restart the currently selected DVR server The Shutdown button will shutdown the currently selected DVR server The Parameters button will open up the Remote Setup window p 82 The User Admin button will open the Remote User Admin window p 108 The Close button will exit the Control Remote Host dialog box The Alarm In and Alarm Out tabs will allow the remote triggering of any configured alarm device Using the Start and Stop buttons you can turn on or turn off each of the alarm devices You can remotely toggle the Guard Schedule for each
69. hdog drop down box Select the COM port the Watchdog unit is connected to using the COM drop down box Set the Baud Rate Parity Data Bit and Stop Bit to match the settings of the selected Watchdog unit Refer to the manufacturer s manual for proper configuration settings Keyboard EC 200 A D COM COM1 Baud rate 2400 Data bit Stop bit Parity None Fig 9 42 Watchdog Unisight COM COM1 D Baud rate 9600 D Data bit Fig 9 43 Network Setup This page contains the Network Setup p 102 and Network Schedule p 102 pages Fig 9 44 The Network Setup page configures the network settings Fig 9 45 The Enable Client Connection check box toggles remote access to the Unisight DVR Server The Enable Local Web Server check box toggles the Local Web Server This check box is grayed out in the Web Client Use the HTTP Port field to input a port number for the Web Client to use If you are accessing the DVR Server from outside the LAN you must forward this port through any router to the DVR Server Use the Server Message field to input a port number for the Unisight DVR Client application to use If you are accessing the DVR Server from outside the LAN you must forward this port through any router to the DVR Server The Network Schedule is similar to the Color Scheme Schedule p 84 Unisight DVR System Remote setu T E Z H 7 I j Homepage Esck Submit de Preyeiw setup Remote setup Recordin
70. he DVR system You can disable a user by checking the Disable This User check box Click the Cancel button to exit without saving Click the Confirm button to exit and save the user The Modify User Info button will open the User Info page and allow you to alter an existing user ev radmin gt Default user WW Disable this user WW Fig 9 54 108 Unisight DVR System Authority System shutdown Back to windows Schedule Video Color Motion Advanced setting Playback PTZ control Browse log Manual record motion quard Minimize Backup Snapshot Network access View map Adjust video parameters O O O 9 O N O N i IR Remote control access Fig 9 55 The Assign Authority button will allow you to change the authority permissions of the currently selected user Fig 9 55 You can check each individual check box or use the Authority check box to quickly check all authority permissions The Camera Access button will allow you to grant revoke permission for the selected user for each video channel Fig 9 56 Authority CH O1 CH 02 CH O3 CH 04 E E E E E Fig 9 56 Preview Fig 9 57 When you click the Preview button you will see the Live Preview mode This screen contains the Channel Grid p 110 Grid Layout buttons p 110 Available Channel list p 110 and DVR Control buttons p 111 109 Unisight DVR System Select all Invert Fig 9 57 Channel
71. individual sensor connected to the alarm controller using the Guard tab and the Start Stop buttons The Motion tab will allow you remotely start and stop motion recordings on the DVR Server AA Fig 7 25 78 Unisight DVR System Client Playback The Unisight DVR Client Playback Mode and the Server Playback Mode are the same Refer to the Playback Mode p 54 When using the remote client application some features buttons may be grayed out and inaccessible When using the remote client the Files Backup Manager is the Search Remote Recording File Fig 8 0 Search remote recording file Date 08 08 2007 e Channel CHO k Mode OR 3a 2300 16 09 42 20 09 42 26 09 43 22 09 43 29 09 43 49 09 43 55 09 44 39 09 45 15 09 46 38 09 47 42 UO A 44 09 AG Aa 09 49 553 09 59 55 09 59 55 1 0 09 56 10 09 56 Select all Clear Fig 8 0 The Backup Files Remote Download button brings up the Search Remote Recording File dialog box Fig 8 0 Use the Date drop down box to select the desired date Use the Channel drop down box to select the desired video channel With the Mode drop down box you can select what type of video recording to list You can select All Continuous Motion Alarm Manual and Network video recordings A list of all video recordings will be displayed They are listed as time indexes The start and stop time for each video recording file is displayed Select the desired ti
72. ion El Advanced setting Playback PTZ control C Browse Log LD Manual motion activation deactivation Cl Manual guard activation deactivation Manual record start stop C Minimize Backup Snapshot Metwork access C VIEW map LEI Adjust video parameters Select all Clear Cancel Fig 3 53 44 Unisight DVR System Extra Button The Extra button allows you to determine the version that you are currently running The version number will be displayed in the title bar Fig 4 0 Each Extra Function has a shortcut key associated with it Extra function V2 7 1015HKC Turn off alarm Mute Fause E Map Hide Cancel Function index _ F1 Extra functions Fe Instant playback F snapshot Fe Matrix control Fa Snapshot viewer FS F4 PTZ preset position F10 External command FS Text chat F11 Video parameters Fe Audio volume F12 Remote connection control Tak Switch video channel Ctrli 2 Running E Map Ctrl F All channels start recording Ctrl M Activate motion detection for all Cite All channels stop recording Ctrl D Deactivate motion detection for all Cirl P Adjust PTZ speed ctrl E Channel extend info Ctrl C Force to switch recording file Ctrl 2 Reindex recording files Fig 4 0 Extra Functions F1 This button will bring up the Extra Functions dialog box Snapshot F2 This button will take a snapshot of the currently select video channel Snapshot Viewer F3 This button will bring up the Snap
73. lectrical shock to you or the hardware Remove the side top panel of the case according to the manufacturer specifications Insert the new video capture card being sure to properly seat the card in its appropriate slot Fig 1 5 Fig 1 5 Optional But required for live preview audio Install the gray Live Audio Cable to the white connector labeled out on the video capture card Install the other end of the Live Audio Cable to the black connector labeled CD In on the motherboard If you are installing multiple video capture cards the audio from each card needs to be daisy chained in order to have live preview audio Starting with the first video capture card install the Audio Link cable short cable colored yellow orange red and brown to the white connector labeled out Install the other end of the Audio Link cable to the next video capture card s white connector labeled in Once the Audio Link cables have all been installed continue the installation of the Live Audio Cable on the last video capture card as instructed After you have installed the capture card re assemble the case according to the manufacturer specifications Now start up the DVR machine and install the drivers You can use the Windows Device Manager to install the drivers manually or use the automatic driver install program located in the Drivers folder in the Unisight DVR software installation 12 Unisight DVR System Initial Startup Initial Setup Do
74. ler from the Type drop down box To configure the communication settings for your alarm relay controller press the COM Port button which will bring up the Communication Port dialog box Fig 3 9 Set the correct device settings using the associated drop down boxes There may be a Watchdog card installed in the Unisight DVR Server in which case the COM setting needs to be set to that of the Watchdog E Setup Channel list Server name techstation Import contig Export contig The Camera Priority button Fig 3 10 will open the Camera Action Priority dialog box Here you Camera ColorMotion Schedule Alarm action Relation Guard schedule PTZ Current alarm device Mainvanlala Alarm and motion detection vw Alarm recording vw Popup E Map vw Show motion area vw Enable motion og snapshot delay O me L 2000 Recording duration 10 25 600 Alarm duration 60 0 7 200 short message DTN E Mail Log gt User gt E Map Fig 3 7 vw Single screen previews Advanced Environment ErrordMotion output trigger Shov local alarm light vw Enable voice alarm Alarm response gt Camera priority a COM port SMS Center Enable action w i Clear alls Apply Cancel can raise or lower the priority of individual channels When the Single Screen Preview feature is enabled the channel with the highest priority will remain visible This feature brings the alarm condition to your
75. level The currently selected motion zone will be highlighted white the rest will be red To mask the currently selected motion zone check the Mask Area check box Use the Switch button to cycle through the existing motion zones To remove a motion zone or masked are click the Delete button while the desired zone is currently selected Use the Sensitivity field to input a sensitivity level from 1 highest sensitivity to 100 lowest sensitivity gt Brightriess 1 100 z pm emm as 07 098 bed CH O O sd ER T a 1 A dl L ms Contrast 1 100 Saturation 1 100 Huefi 100 Default Switch Delete Clear Sensitivity 1 100 5 Mask area Fig 9 9 The Color Scheme Schedule will allow you to configure the scheduling options for the Color Schemes Fig 9 10 To select a scheme use the Color Scheme drop down box Next select a Time Scheme by left clicking on one of the listed Time Schemes The selected Time Scheme will be displayed on the bottom of the page Left click the left arrow to apply the selected Time Scheme to a day of the week To quickly copy the same Time Schedule to every day of the week use the Copy To button Be sure to check the Activate Schedule check box to enable the schedule The Delete All button will clear the applied Time Schemes 84 Unisight DVR System Color scheme Schemel1 Schedule Channel list Sunday Monday 1 Schemel 2 Scheme2 S CH O2 Tuesday i Schemel 3 Scheme
76. lick the Export Config button The standard Windows Save dialog box appears where you will be able to choose the name and location to save your configuration file to To import a configuration file click the Import Config button The standard Windows Open dialog box appears where you will be able to select a compatible configuration file to import Once you import a configuration file the settings will be automatically applied 40 Unisight DVR System Environment Tab Fig 3 43 System Startup To have the Unisight DVR software application automatically log in to Windows XP 2000 on startup check the Auto Administrator Login When Windows Is Started check box If the Unisight DVR Server is to be added to a domain click the Password button and type in the domain password in the New Password and Retype fields To have the Unisight DVR software application start when Windows XP 2000 loads check the Auto Startup This Program check box The Auto Reindex Recording Files check box will reindex all recorded video files on startup E Setup E Channel list Camera Color Motion Schedule Alarm actions Relation Guard schedule PTZ Advanced Environment System startup w Auto administrator login when Windows ls started Passyord gt Auto startup this program Auto reindex recording files Environment w Enable client connection Adjust clock gt gt HMetwork ports gt Log info keeping period 30 days 1 999 vw Auto restart Everyday e 06
77. lling the video capture card The necessary drivers for the hardware are contained in these packages Insert the Unisight DVR software installation disk into your CD DVD drive After inserting the CD the introductory screen appears Fig 1 0 DIGITAL VIDEO RECORDING SURVEILLANCE SYSTEM WOW VWUNISIGHT MET COPYRIGHT IE 2006 UmsauT Dora TECHNOLOGIES Inc Email inquiry unisight net A ear AN Fig 1 0 Select which software components you want to install After you have made your selection click the Next button to continue with the installation Fig 1 1 Unizight DF Choose Components Choose which Features of Unisight DYR Software vou want to install Check the components vou want to install and uncheck the components you dont want bo install Click Next to continue Select components to install a Description Unisight Server Unisight Client Space required 71 2MB Fig 1 1 Unisight DVR System Although the default installation location is C Program Files Unisight DVR you can select any folder located on your primary hard disk drive Once the location has been set click the Next button Fig 1 2 Now choose 1f you want shortcut components to install to the Windows Start Menu and click the Install button Fig 1 3 Unisight DE Choose Install Location Choose the Folder in which to install Unisight DND Software Setup will install Unisight DYR Software in the Following Folder To install in
78. luded on this page Left click the triangle to expand collapse menu items E information A Ed X UNISIGHT Homepage X System summary Information Host Software version b Mainboard E Keyboard b Mouse E BIOS F CPU E Memory Video controller F Sound device Network interface card Operating system gt Slot F Serial port b Physical disk F Logical disk Fig 9 71 e Homepage Back System status Channel status Alarminstatus AlarmOut status Service Logical disk MIC flux E E d memor CPu E Fig 9 72 115 Unisight DVR System Remote Status Fig 9 72 This page contains the System Status p 116 Channel Status p 116 AlarmIn Status p 116 and AlarmOut Status p 116 pages The System Status page contains the Process Service Memory CPU Logical Disk and NIC Flux pages The Process page displays the currently running processes on the DVR Server The Service page displays the currently active services running on the DVR Server The Memory CPU page displays the current memory and CPU usage on the DVR Server The Logical Disk page displays each drive connected to the DVR Server along with the total size and free space of each partition The NIC Flux page displays the current bandwidth usage for the DVR Server The Channel Status page displays the current status of each video channel Fig 9 73 The Channel Name Recording Status Motion Detection Status and Netwo
79. mallest file size but with lower video quality You can set the Frame rate from 1fps to 30fps The higher the frame rate the smoother the video You can also choose to encode the video using VBR with the VBR Enabled check box With VBR enabled you can limit the bit rate when there is high motion with the Limit Bit Rate setting There are up to 5 different resolutions available QCIF 176x144 CIF 352x240 DCIF 528x360 2CIF 704x240 and 4CIF 704x576 The Video and Video Audio radio buttons set the audio recording mode either video recording only or video recording with associated audio channels The Change On Alarm feature allows a separate video scheme to be used during an alarm condition Use the Setup button next to the Change On Alarm checkbox to configure the video settings Compress Trans if enabled allows you to set a different video quality for all the client connections by using the Setup button next to the Compress Trans checkbox This allows you to raise or lower the client video quality to compensate for bandwidth usage for varying network speeds Others The Disk Group drop down box selects which disk group each video channel writes to The Signal Lost Alert will write a log entry when a video feed is disconnected from the DVR when enabled The Show Preview checkbox will toggle the live video preview on the main DVR screen The Memo feature allows an additional description of the video channel to be input when the manual
80. mes by left clicking on the time To select multiple video recording files hold down the Shift key and left click on several video recording files The Select All button will highlight all listed recorded video files The Clear button will clear the selection Once you have your video recording files selected they will highlight blue Click the Download button to start the download A standard Windows save dialog box will appear 79 Unisight DVR System Web Client You can access the Unisight DVR Server from Internet Explorer 6 or higher The Web Client enables you to view up to 16 live preview video channels simultaneously You can also review previously recorded video files and download them to the local machine using the Web Client Port 80 must be forwarded to the Unisight DVR Server and the Enable Web Server check box needs to be checked p 41 42 in order to use the Web Client Initial Startup First type in the DVR Server s IP address beginning with http into the Address Bar and press enter Choose English to start the Web Client Fig 9 0 The default port for the Web Server is port 80 If you have changed this be sure to enter in the port along with the IP address when connecting to the Unisight DVR Web Server If you are have not already done so click the Download button to download the required ActiveX control Fig 9 1 In the File Download dialog box click the Run button Fig 9 2 APM ENGLISH Fig 9 0 If you
81. mote Playback Unisight DVR System System Requirements Unisight DVR Server All of the following information is highly recommended for optimum performance and to facilitate a solid understanding for usage and maintenance of this DVR system and its many capabilities To save time in the future you can print a copy of this document Click on the File menu and select Print select which printer you want to print from and click Ok Congratulations on your purchase of the Unisight DVR system To properly operate and control the DVR system you have purchased the following system requirements are considered to be the absolute minimum Server Hardware Requirements e 256Mb of system RAM e 1 8Ghz CPU e 2 hard disk drives 1 for the O S 1 for the recorded video storage e 64Mb VGA card e Video capture compression card Server Software Requirements e Windows 2000 Windows XP at the time of this release Windows Vista and beta packages have not been tested e DirectX 8 1 or higher Client Hardware Requirements e 25Mb of available hard disk drive space e 256Mb of system RAM e 1IGhz CPU e 64Mb VGA card e Network interface card Client Software Requirements e Windows 2000 Windows XP at the time of this release Windows Vista and beta packages have not been tested e DirectX 8 1 or higher Unisight DVR System Installation Install DVR Software You should always attempt to install the DVR software application prior to insta
82. n will close the connection to all connected video channels Fig 7 5 messie a El Fig 7 3 Fig 7 4 Fig 7 5 66 Unisight DVR System Camera Status LEDs There are two rows of Camera Status LEDS Fig 7 6 You can connect to a maximum of 64 channels at once The more channels you connect to the more system resources are needed to display the video feeds from the DVR Server Each Camera Status LED will be a different color for each of the different connections Color Connection Indicator GREEN Connected GRAY No Connection RED Connection Lost BLUE Local Recording Fig 7 6 DVR Control Buttons Fig 7 7 7 8 The Extra button opens the Extra Function dialog box p 45 The Connect button opens the Connect Server dialog box and will allow you to connect to up to 64 different video channels p 70 The Disconnect button will close the connection to the currently selected video channel The Record button will toggle the recording status of the currently selected video channel The video recording will be saved to the local hard disk drive The Lock button is used to lock and unlock the Unisight DVR Client application p 18 If you left click the Hide button the Client application will minimize to the System Tray The Exit button will close the Client application p 18 The PTZ button will allow you to move any PTZ camera configured on the Unisight DVR Server that you are connected to p 53 The E Map button will
83. name of the sender in the Sender field Input the address where the e mail will be sent from in the Sender Address field Type in the address of the mail server in the SMTP Server field If your mail server requires a username and password check the My SMTP Server Need Checking Authorization check box After the box 1s checked the Username and Password field will highlight Fill in both the Username and Password fields The Alarm Response page allows you to assign a sound file to be locally through the DVR speakers when a sensor is triggered Fig 9 33 Use the Sound File field to assign a sound file to each sensor Type in a description in the Hint Message field This Hint Message is e mailed if the E mail feature is enabled and configured 97 Unisight DVR System Alarm response Sound file Clear Fig 9 33 The Camera Priority page allows you to assign different video channels a higher priority Fig 9 34 This priority list is used along with the Single Screen Preview p 25 A video channel with a lower priority will not popup while a video channel with a higher priority is being displayed Camera priority cH 01 CH 04 y CH 02 Reset Fig 9 34 PTZ Setup The PTZ Setup page contains the PTZ p 98 and Sensor Relation To Preset Point p 100 pages Fig 9 35 The PTZ page allows you to configure the PTZ setup Fig 9 36 Start by selecting the PTZ camera from the channel list the video feed from the P
84. nd server The Status Info check box toggles the RT recording time overlay on the lower left of the video feed The Instant Playback check box enables the Instant Playback feature p 49 Input the number of days 1 999 you want to save the server log into the Log Info Keeping Period field After the specified number of days the server logs will be overwritten starting with the oldest log The Auto Restart check box enables the automatic DVR restart feature This feature will shut down the DVR Server application log off Windows and restart the system You can choose to restart everyday or once a week You must also input the time you want the DVR Server to restart It is recommended to restart at least once a week The Auto Shutdown check box enables the automatic closing of the DVR Server application This feature will only exit the DVR Server application Windows will continue to run The Power Off When Shutdown check box will turn off the entire system when scheduled The Auto Start check box enables the automatic power on of the Unisight DVR System For this feature to function properly the 5 VSB jumper must be connected on the Watchdog unit The Snapshot Path specifies where the saved snapshots will be stored To change the location click the yellow open folder icon A standard Windows open dialog box will appear Channel associated Channel description CH 01 Channel list Signal lost alert w CH 02 Show preview w CH 03
85. ns are displayed under the CPU Usage meter labeled Link This meter will increase by 1 for each channel that the Unisight Remote Client application or the Unisight Remote Web Client connects to There are two rows of gray squares This is the Available Storage display For each device configured as storage a square will light up blue If the Unisight DVR Server application is currently writing video footage to that drive the blue square will be blinking green The Available Storage display will also tell you which disk letter you are writing to and also how much storage space is free in Mb Fig 2 3 10 17 2007 13 13 02 CPL Usage Free spacer hy 3774 Fig 2 3 Camera Status LEDs The Camera Status LEDs will tell you how each recording channel is functioning Fig 2 4 RED Video signal lost YELLOW Motion mode recording BLUE Continuous mode recording GREEN Manual recording BROWN Guard Schedule activated Audio Fig 2 4 Channel Grid The channel grid contains the live video preview This is where you will see all of your video camera feeds You can select each channel by left clicking the mouse to activate the live audio preview for that channel To maximize a video channel double click it To restore the Channel Grid double click the video feed again There is also a full screen mode that you can toggle by clicking the right mouse button on any video channel 15 Unisight DVR System Grid Layout The
86. nse button The Alarm Response Setting dialog box will appear Fig 3 11 Alarm response setting Alarm response Motion response Error response Sensor 17 File selection Cancel Fig 3 11 The Alarm Response tab will allow you to set separate sound files for each sensor connected through the alarm relay controller With the Motion Response tab you will be able to specify a separate sound 27 Unisight DVR System file for each video channel Under the Error Response tab there is only a single sound file for all errors To configure a sound file left click on the desired sensor channel and click the File Selection button The standard Windows Open dialog box opens Navigate to the directory where your sound file is located and left click on it Once the sound file 1s highlighted click the Open button The Popup E Map check box enables the E Map feature If checked when an alarm signal is detected the system s electronic map will automatically popup To configure the E Map left click the E Map button the Map Setting dialog box will open Fig 3 12 To configure the map click the Setup button The Map Content Setting dialog box will appear Fig 3 13 S Map setting Fig 3 12 Map content setting Map Map file Description Server address Server message port ideo Sensor Alarm output VWideo O1 Video O Video UI Video O4 Video D VWideo O6 Video DU VWideo O6 Video DO VWideo 10 Video
87. nsitivity level Set a lower sensitivity for objects that appear closer in the field of view and a higher sensitivity for objects that are further away in the field of view To switch between motion detection zones use the Switch button The currently selected motion detection zone will highlight in white while the others will be red The Delete button will remove the currently selected motion zone while the Clear All button will delete all motion detection zones If no motion detection zone are configured the entire video feed will act as a single motion detection zone The mask button will create a black square over the currently selected motion zone This masked zone will also appear in the recorded video There are 5 configurable Schemes for video signal parameters You can adjust the brightness contrast saturation and hue for varying video signal situations such as low light and direct sunlight Pressing the Default button will revert the video signal settings back to the factory default for the currently selected Scheme 21 Unisight DVR System Schedule Tab Fig 3 3 You can set separate schedules for Continuous Mode Motion Mode Color Video and Allow Network Access Each different schedule tab has a user definable schedule Kach Ej Setup Channel list Camera Color Motion Schedule Alarm actions Relation Guard schedule PTZ Advanced Environment PTs CH Continuous mode Motion mode Color Wideo Allow network access C
88. o configure a user click the Modify button Fig 3 49 To add a user click the Add User button Fig 3 50 After clicking the Add User button the Add User dialog box will appear Fig 3 51 x df Fig 3 48 Fig 3 49 Fig 3 50 Add user User level E Admin Advanced Medium Username Password Retype Fii Full name Description Disable this user Defaut user Authority gt Camera access Cancel Fig 3 51 43 Unisight DVR System Select the User Level using the top radio buttons Fill in the Username Password Retype Password Full Name and Description fields You can deactivate a user by checking the Disable This User check box To make a user the default user check the Default User check box To enable specific cameras that will be accessible by the user click the Camera Access button The Camera Access dialog box appears Fig 3 52 Simply check or uncheck each camera that you want to enable or disable To enable all cameras click the Select All button To disable all cameras click the Clear button a il Camera access Ka Authority cH 01 CH 02 CH O3 CH 04 select all Fig 3 52 To assign permissions granted to the user click the Authority button The Assign Authority dialog box will appear Fig 3 53 Check or uncheck each of the configurable permissions for the user Assign authority Authority Dl system shutdown C Back to Windows C schedule video Color Mot
89. on BIE Function Fal Function BS _ Channel CH 03 CH 04 System log 10 30 2007 15 15 26 10 30 2007 14 24 44 10 30 2007 14 21 43 10 30 2007 14 21 43 10 30 2007 14 21 43 10 30 2007 14 21 42 10 30 2007 14 20 17 10 30 2007 14 20 17 10 30 2007 14 20 16 10 30 2007 14 15 25 10 30 2007 14 06 58 10 20 2007 13 57 20 10 30 2007 13 57 18 10 30 2007 13 57 18 10 30 2007 13 54 57 10 20 2007 13 51 57 Alarmin control Recording status ba Unisight DVR System Update Print current page Description Disk group 1 current storage path is Dil Supervisor lock system Unlock system key System minimized System restored Lock system key Unlock system key System minimized Supervisor left system setting Disk group 1 current storage path is Dr Supervisor entered into system setting Supervisor unlock system System restored Lock system key Supervisor lock system Unlock system key dest Fig 9 74 AlarmQut control Windows control Motion detection status Scheduled SW Connect Scheduled hl Fig 9 75 Print all page Type All ES Supervisor Supervisor Supervisor Supervisor 10 25 2007 Supervisor Supervisor Supervisor Supervisor Supervisor Supervisor Supervisor Supervisor Supervisor Supervisor Supervisor Supervisor gt 1 5 431 Video I 09244 iy ME Disconnect The Channel Control page Fig 9 75 allows you to remotel
90. onfigured motion zones on the Live Preview mode The Enable Motion Log check box will write a log entry each and every time motion detection triggers a recording or stops a recording In multiple camera situations where motion is constantly triggered this may not be wanted The log file will have many entries for motion and may make it difficult to read through The Error Motion Output Trigger check box enables motion detection based external alarm device triggering The Show Local Alarm Light check box will toggle the display of an alarm light on the Unisight DVR Server when an alarm condition is detected This will aid in the identification of certain situations for any security personnel monitoring the DVR Current alarm device Alarm and motion detection Alarm recording Popup E Map Single screen preview Show motion area Enable motion log Error Motion output trigger Show local alarm light Enable voice alarm MOM MN Snapshot delay ms 0 3000 Recording duration 1 s 5 600 Alarm duration s 0 7200 Fig 9 27 94 Unisight DVR System The Enable Voice Alarm check box toggles an audible sound that plays through the speakers connected to the Unisight DVR Server The Snapshot Delay specifies the number of milliseconds to wait before automatically taking a Snapshot The Recording Duration field specifies the length of time in seconds to record after the alarm has been triggered The Alarm Duration field specifies the length o
91. onnect all current alarm connection Fig 7 10 Extra Functions F1 This button will bring up the Extra Functions dialog box Snapshot F2 This button will take a picture of the currently selected video channel Snapshot Viewer F3 This button will bring up the Snapshot Viewer dialog box p 45 PTZ Preset Position F4 This button will bring up the PTZ Preset Position Control dialog box p 68 Unisight DVR System 47 The PTZ Preset Points are stored in the PTZ camera itself and will be the same on the server side and the client side Text Chat F5 This button will bring up the Chat Room dialog box p 48 Audio Volume F6 This button will allow you to raise and lower the audio volume p 49 Adjust PTZ Speed Ctrl P This button will bring up the Adjust PTZ Speed dialog box p 49 You can also set the PTZ Speed to that of the Unisight DVR Server using the check box on the bottom of the dialog box Control Remote Host Machine F7 This button allows for remote activation of certain features Fig 7 11 The configured servers are listed on the left To gain control of a remote Unisight DVR Server left click the server name The server IP address can also be displayed alongside the server name by checking the Show Server Address check box There are 5 actions that you can control remotely Alarm In Alarm Out Guard Record and Motion To start or stop any of these first left click the desired field and click the Sta
92. or by left clicking the sensor name in the list it will highlight green Now type in the Public View number next to the desired video channel in the Matrix Input field Each time the sensor is triggered the configured video channel will appear on the Public View number Matrix Baud rate MA Data bit Fig 9 39 Sensor relation to matrix input Channel Matrix imput 2 Sensor 02 3 Sensor 03 4 Sensor 04 Fig 9 40 Remote setup N wg S UNISIGHT besen Homepage Hack Submit Preveiw Setup Recording setup Alarm device Motion detect setup Error setup Keybos rd A A A a El Alarm action Watchdog SE EE AE EDE E st Pee EE Ed Ra ER ei RR ETTER SE EE GE E El FTZ setup amp Matrix setup de Other device Network setup Advanced setup Customization Fig 9 41 101 Unisight DVR System Other Device The Other Device page contains Keyboard p 102 and Watchdog p 102 pages Fig 9 41 The Keyboard page allows you to configure an external device to control the connected PTZ cameras Fig 9 42 Use the Keyboard drop down box to select the supported PTZ control keyboard Match the COM Baud Rate Parity Data Bit and Stop Bit settings to that of the selected keyboard Refer to the keyboard s manual for the correct settings The Watchdog page allows you to configure any installed Watchdog units Fig 9 43 Select the supported Watchdog unit from the Watc
93. protocol PELCO D CHA 02 CHA 05 CA 04 Use key F4 to control PT preset position Address index 01 COM port gt Fast response to remote contral Keyboard Server name techstation Import contig gt Export contig gt User Cancel Fig 3 23 To configure a PTZ camera select the video channel that the PTZ camera is connected to in the Channel List Click the Load button to bring up the Predefined PTZ Ctrl Code dialog box Fig 3 24 Locate the supported PTZ camera by scrolling down the list Left click on the PTZ camera It will highlight blue Then click the Ok button Once the protocol 1s selected assign the correct address to the PTZ camera using the Address Index drop down box Then click the COM Port button to bring up the Communication Port dialog box Fig 3 25 Configure each drop down box as specified by the PTZ camera manufacturer and click the Ok button to return to the PTZ tab 34 Unisight DVR System Predefined PTZ ctrl code AB 282001 ACES HY AD ADRSOS6 DU Fastdome DU DCTRLS DRAGON EE FMSEOOD GRA 2000 HTEOO HY JD dv 2000 KORY Mchaly KOMY MO KOM MTRSO0 KORY IMC Kallaite L di er Fig 3 24 Communication port Baud rate 2400 Parity Mone Cancel Fig 3 25 To select an external PTZ control device select the supported device from the Keyboard drop down box and click the COM Port button to bring up the Communication Port dialog box
94. re 1 4 and 16 Once the Matrix Regions are setup restart the Unisight DVR Server application and press F8 A Public View is a single logical monitor Public View 01 is the top left logical monitor on the first physical monitor The next Public View is the next logical monitor starting from left to right like lines in a paragraph To assign a video channel to a Public View select the desired Public View from the Public View drop down box Then left click on the video channel you wish to display You cannot display two video channels at the same time on any logical monitor To have the logical monitors cycle through video channels check the Enable Auto Switching check box Then left click on the video channel that you want to display first After the video channel is highlighted in blue click the Option button which will open the Matrix Control Info dialog box Fig 4 11 Check Relation To Public View and input the time span you want this video channel to display before switching in seconds into the Switching Interval field You can also input a description of the video channel in the Description field Click the Ok button to finish Repeat this process for each video channel that you want to cycle through Matrix control info w Relation to public view Switching interval E 301 6001 Description ideoc01 j Fig 4 11 External Command F10 This button will execute any configured external command Video Parameters F11 Allows you
95. rk Connections are displayed You can connect to a video channel by selecting it and clicking the Connect button To close the connection to the channel click the Disconnect button The AlarmIn Status and AlarmOut Status pages will display the current state of each external sensor and each external alarm output device System status Charne ats Alarmin status AlarmOut status Channel Recording status Motion detection status Network connection W Scheduled CH 03 si Scheduled D CH 04 0 Connect Disconnect Fig 9 73 System Logs Fig 9 74 Click the Update button to refresh the display Select a log file to view by highlighting a day from the Date list To print the currently visible page click the Print Current Page Button To print all pages of the log file click the Print All Page button The Type drop down box will allow you to filter the log files based on Info Warning Function Error and All entries While viewing the System Log the Type drop down box will filter according to Application Security and System Use the Homepage button to exit the System Logs page Remote Control Fig 9 75 The Remote Control page contains the Channel Control p 117 AlarmIn Control p 118 AlarmOut Control p 118 and Windows Control p 118 pages 116 IP info BP Function BiB Function SR Function BP Function SR Function SR Function SR Function SR Function I info SR Function SR Function BIB Function BP Functi
96. rt or Stop button Control romote host EW Alarm in Alarm out Guard Record Motion pen EN zo w Show server address Start stop Close Fig 7 11 Start A Voice Chat F8 This button will start a voice chat This feature requires a set of speakers connected to the Unisight DVR Server and a microphone connected to the client machine For two way communication a microphone and set of speakers are required on both the server and the client Once clicked the Extra Function dialog box will disappear and the voice chat will start Video Parameters F11 This button will bring up the Video Parameters dialog box Fig 7 12 You can adjust the Brightness Contrast Saturation and Hue of the currently selected video channel by left click and dragging the slider up and down If you change these video parameters they will also affect the remotely recorded video files 69 Unisight DVR System Video parameters Brightness Contrast Saturation Fig 7 12 Disconnect All F12 This button will disconnect all video channels from the connected server s Running E Map Ctrl A This button will close the open E Map Channel Extend Info Ctrl E This button will open the Notice dialog box Fig 7 13 The video channel s extend info 1s taken from the server side and displayed on the client machine Use the Unisight DVR Server application to configure the Channel Extend Info p 37 Hotice ES Fig 7 13
97. s you to link an external sensor device to trigger a preset position on a PTZ camera Fig 9 37 Start by selecting the desire configured sensor from the list it will highlight green Use the Preset Point field to type in the PTZ Preset Point number next to the video channel that is configured as a PTZ camera Sensor relation to preset point Description 2 Sensor 02 3 Sensor 03 4 Sensor 04 J Sensor 05 6 Sensor 06 e Fig 9 37 INISIGHT UNIS T A Homepage gt Hack Submit Preveiw setup Recording setup Alarm device Motion detect setup Matrix Error setup Alarm action Sensor relation to matrix input PTZ setup KS Matrix setup Other device Network setup Advanced setup Customization Fig 9 38 Matrix Setup The Matrix Setup page contains the Matrix p 100 and Sensor Relation To Matrix Input p 101 pages Fig 9 38 The Matrix page contains the configuration options for the supported matrix cards Fig 9 39 Use the Matrix drop down box to select the matrix card that has been 100 Unisight DVR System installed The COM Baud Rate Parity Data Bit and Stop Bit may not need to be configured depending on the type of matrix card selected Refer to the manufacturer for required setup options The Sensor Relation To Matrix Input page allows you to link an external sensor to a channel on the external matrix display grid Fig 9 40 Select a sens
98. shot Viewer Fig 4 1 Select the video channel using the Channel drop down box Select the date using the Date drop down box Select the recording type using the Type drop down box Each snapshot taken for that specific channel date and recording type will be listed on the left side To view a snapshot left click the time To increase or decrease the displayed image size use the Zoom and Zoom buttons To delete the snapshot click the Delete button To clear the display click the Clear button To save the displayed image click the Backup button Select the Device Type and Drive List that you want to save to and click the Save button Fig 4 2 A BACKUP DATA folder will be created with the saved image To print the displayed image press the Print button 45 Unisight DVR System ei Image files browse and print Channel CH 02 k Date 2007 08 07 e Type lt All gt Ke OOM Zoopmt Delete Clear Backup Print Fig 4 1 Kb 1 Select path Device type Local disk Drive list ME s7 Free space 691 69 MB space needed 0 0 7 MB Save Cancel Fig 4 2 46 Unisight DVR System PTZ Preset Position F4 This button will bring up the PTZ Preset Position Control dialog box Fig 4 3 Begin by selecting the video channel that has a PTZ camera configured in the DVR main window Then press the PTZ button to bring up the camera controls p 53 Point the PTZ at the desired location and press F4 on the
99. t spans multiple recording files The Minimal Disk Space field defines the amount of free hard disk drive space needed on the client machine to record video locally The Overwriting Trigger Value specifies the amount of free hard disk drive space 1s left before the client application starts overwriting the oldest recorded video files The To Be Released Space field determines how many recorded video files will be deleted to make room for more current video files The Enable Auto Overwriting check box will overwrite the oldest recorded video with the currently recording video files without any input from the user when enabled To specify a directory to 74 Unisight DVR System store these recorded video files click the yellow open folder by the Video File Path field A standard Windows open dialog box will appear Simply locate the desired directory ES Setup x Connection Record Advanced Environment setting Single file recording time 15 Minute Minimal disk space 0465 MO 024 4096 Motice System will stop recording when the disk space is less than the amount given above Owverweriting trigger value 1024 MENL1O24 2048 To be released space 2045 MB 512 40961 vw Enable auto overweriting ideo file path C Record Data Cancel Fig 7 21 Advanced Tab Fig 7 22 Signal Setting The Quality drop down box sets the signal quality A higher quality setting will record video files with a higher level of detail and a larg
100. tion based recording The Guard button toggles the alarm sensors on and off The Lock button will toggle the availability of all buttons on the main DVR screen until the correct username and password are entered p 17 The Hide button will minimize the Unisight DVR Server application The Exit button will close the Unisight DVR Server application p 18 The PTZ button will allow you control PTZ cameras connected to the system p 53 The E map button will bring up the electronic map p 28 The Playback button will switch to the Playback mode p 54 The Setup button will allow you to configure the system p 19 17 Unisight DVR System Locking Unlocking and Exiting The Lock button will allow the user to disable all buttons that appear on the main DVR screen This locks out unauthorized access to the Unisight DVR Server application Pressing the Lock button when the system is locked brings up the Unlock System dialog box Fig 2 11 Select your username from the Username dropdown box type in your password in the Password field and click the Ok button to unlock the system To Exit the Unisight DVR Server application simply click the Exit button A dialog box similar to the Unlock System dialog box appears Follow the same instructions to exit the DVR software 4 Login Unlock system Admin SA Username Supervisor id Passweord SE Fig 2 11 18 Unisight DVR System Server Setup Setup Button Clicking the Setup bu
101. to change the brightness contrast saturation and hue Remote Connection Control F12 This button will open the Remote Connect dialog box Fig 4 12 This window will display each connected user their IP address and which video channel they are connected to To get an updated list click the Refresh button To disconnect all connected remote clients click the Disconnect All button To disconnect a single video channel connection left click the desired channel Once the video channel is highlighted in blue click the Disconnect button Jl Unisight DVR System Remote connect Username Address Channel Supervisor 127 0 0 1 supervisor 127 0 0 1 supervisor 127 0 0 1 Supervisor 127 0 0 1 Remote Refresh Disconnect Disconnect all Fig 4 12 Running E Map Ctrl A This button will open up the E Map image Activate Motion Detection For All Ctrl M This button will start motion based recording on all video channels Deactivate Motion Detection For All Ctrl D This button will stop motion based recording on all video channels Channel Extend Info Ctrl E This button will open the Notice dialog box To change the Channel Extend Info text refer to the Extend Info button p 32 Reindex Recording Files Ctrl Z This button will reindex all recorded video files 52 Unisight DVR System PTZ Button To gain control of a configured PTZ camera first select the video preview channel in the DVR main screen Then click on
102. to change the day selection to the opposite of the currently selected To clear the schedule click the Clear button The Time Schedule button brings up the Setup Time Schedule dialog box Fig 3 5 Here you can change the configured time periods for each of the 16 Schemes Use the Time Period drop down boxes to select the starting hour and minute and the ending hour and minute You can use the Standard drop down box to quickly apply the preconfigured common time periods Use the Clear button to erase all configured time periods for the selected scheme 23 Unisight DVR System Setup time schedule Time period Scheme 3 Time period qq Time periodi2y 42 Time periodi Ar 48 Time periodi Time periods Time period 67 Time period Time periods standard Fig 3 5 The Holiday button will bring up the Holiday Setting dialog box Fig 3 6 Use the Select A Date drop down box to bring up a graphical calendar to select individual dates Click the Add button to add the date to the Holiday Date List Use the Clear button to quickly erase all added dates from the list To delete an individual date left click the date then click the Delete button Holiday setting Date list Select a date 12 25 2007 fi 4f200F 07 04 2007 Fig 3 6 24 Unisight DVR System Alarm Actions Tab Fig 3 7 The Device Selection button will bring up the Device Select dialog box Fig 3 8 Select your supported alarm relay control
103. ttings when an alarm condition is detected such as motion detection The Compress Trans check box enables the dual stream capability of the capture card if supported The Unisight DVR Server will record at the specified Video Scheme and send a separate video quality to the clients by using the Resolution Frame Rate and Compression settings Video scheme Scheme 1 D Channel list Gei Video Resolution CIE E CH D3 videa Audio Frame ratelfpsl 30 e CH 03 Compression 8 j CH O4 w VBR enabled Limit bit rate Change on alarm de Compress trans A Resolution Resolution Frame rate fps Frame rate fps Compression Compression Fig 9 15 The Video Scheme Schedule is similar to the Color Scheme Schedule p 84 The Continuous Schedule is similar to the Color Scheme Schedule p 84 Alarm Device The Alarm Device page contains the Device Type p 88 Sensor Info Setup p 90 Output Info Setup p 90 Sensor Relation To Output p 91 Sensor Relation To Channel p 91 and Guard Schedule p 91 Fig 9 16 The Device Type page contains the configuration options for all supported external alarm controllers Fig 9 17 The Device Type drop down box specifies which supported alarm controller is connected to the Unisight DVR Server Set the Com Baud Rate and Parity to match the settings of the connected alarm controller The Data Bit and Stop Bit may not require configuration depending on the type of
104. tton will open the Setup dialog box Fig 3 0 The Setup dialog box is divided into 9 different tabs Camera p 20 Color Motion p 21 Schedule p 22 Alarm Actions p 25 Relation p 31 Guard Schedule p 33 PTZ p 34 Advanced p 36 and Environment p 41 E Setup x Channel list Camera Color Motion Schedule Alarm actions Relation Guard schedule PTZ Advanced Environment PTE LH CHA 05 CH 04 Scheme Compression Frame ratel fpa Resolution Video Scheme ah Schemecii e 10 30 M CIF e h Videol udio VBR Enabled Limit hit rate Estimated bit rate CBR mode 393 MBHour Change an alarm vw Compress trans Setup Copy to Others Server name Disk group Group techstation w Signal lost alert w Show preview w Allow network access Import contig Export contig gt User Cancel Fig 3 0 The Log button will open the Log Viewer dialog box A log file 1s created for every day the Unisight DVR Server application 1s running p 72 Unisight DVR System Camera Tab Fig 3 0 Channel Selection Using the Channel List you can select the desired channel by left clicking on the channel name You can configure different settings for each individual channel or apply them to multiple channels using the Copy To button Video Scheme You can configure up to 3 different video schemes 10 grades of Compression are available 1 is the highest compression which will give you the s
105. uble click the shortcut labeled Unisight DVR Server This icon is a blue monitor located on your desktop Once the application loads you will be presented with a log in screen The default selected username is Supervisor The password for this user is left blank for initial setup To log in click the Ok button Fig 2 0 24 Login DVR server Admin Username Supervisor bi Password Fig 2 0 The first time the Unisight DVR Server application 1s run you must select your video standard If you are inside the United States select the NTSC radio button and click Ok Fig 2 1 Select video standard firstly s HTSC Fig 2 1 13 Unisight DVR System Main DVR Screen After you have started the Unisight DVR Server application you should be looking at the main DVR screen Fig 2 2 This screen is contains the DVR Information Window p 15 the Camera Status LEDs p 15 the Channel Grid p 15 the Grid Layout buttons p 17 and the DVR Control buttons p 17 10 03 42 CPU Usage Link Disk 10 19 2007 Free spacerhy 2993 BERERE EECHGE SETUP PLAYBACK PTZ 14 Unisight DVR System DVR Information Window The top of the DVR Information Window displays the current date followed by the current time underneath The current time is formatted for 24 hours The CPU Usage is also displayed This meter is displayed in of CPU cycles used from 0 usage to 100 usage Remote client connectio
106. y Starts playback of the currently selected video file from the beginning Pause Pauses playback on the currently selected video file Step Forward Moves the time slider forward one frame also pauses video playback Increase Speed Speeds up the playback speed Next File Jumps to the next video file Multiplay Starts playback all selected video channels Stop All Stops playback on all video channels Clip Creates a clip of the currently playing selected recorded video file Smart Search Allows you to search recorded video files for motion based activity ex missing objects There are also a set of 4 more Playback Controls Fig 6 6 The Mute button will toggle playback audio The Volume buttons will increase or decrease the playback volume The Clip button will allow you to create a small video file To create a clip select a video file and press the Play button When you want to start the clip press the Clip button The Clip Video File dialog box will appear Fig 6 7 When you initiate a clip this window will display the Start Time only To begin your clip press the Ok button Clip video file start time 1 2030 stop time unselected Fig 6 7 The Clip Video File dialog box will disappear and the video file will start playing again When you want the clip to end press the Clip button again The Clip Video File dialog box will reappear but will now display a Stop Time At this point you can
107. y start and stop Manual video recordings The Recording Status column displays the current recording status of each channel The color indicators are green manual recording yellow motion recording blue continuous recording gray not recording Select a channel from the Channel column and click the Connect button to see the video feed from that channel The Disconnect button will close the connection to the currently 117 Unisight DVR System selected channel Once connected double click the Recording Status camera icon to start a manual recording on the Unisight DVR Server Double click again to stop the recording The AlarmIn Control page allows you to activate deactivate external sensors that do not have a Guard Schedule p XX set Fig 9 76 To activate a sensor select the sensor from the AlarmIn column and double click the activation icon in the Guarding Status column To deactivate the sensor double click the Guarding Status icon again Channel control lt Alarmin contro AlarmQut control Windows control AlarmIn stection statu Guarding status Sensor 02 WA Undetected E Manual Sensor 03 WA Undetected a Sensor 04 Undetected Sensor 05 Ea Undetected ES Fig 9 76 Channel control Alarmin control AlarmQut contro Windows control AlarmOut Output 02 ES Stop Output 03 Triggered Output 04 ES Stop Output 05 ES Stop Fig 9 77 The AlarmOut Control page allows you to remotel
108. y trigger any external alarm device Fig 9 77 Select an output device from the AlarmOut column Double click the Triggering Status icon to activate the alarm output device Double click again to stop the alarm output device The Windows Control page allows you to remotely restart shutdown the Unisight DVR Server Fig 9 78 The Restart Remote Computer button will restart the DVR Server The Shutdown Remote Computer button will turn off the DVR Server Channel control Alarmin control AlarmOut control Windows control ES Restart remote computer Shutdowm remote computer Fig 9 78 118 Unisight DVR System Remote Playback Date 2007 10 31 a 09 14 33 09 14 46 09 20 20 09 30 28 OOEUBOUEEEEE en eg Fig 9 79 The Remote Playback page allows you to playback up to 16 channels from the Unisight DVR Server remotely through the Web Client Fig 9 79 Hover your mouse over the Grid Layout buttons for a description of each one Fig 9 80 9 81 Hover your mouse over the Playback buttons for a description of each LU Ge LH Ga LH od EA EA Ed Fig 9 80 uk BR LU be H w Fig 9 81 To playback a video file select a date from the Date drop down box Select a channel from the Cameras drop down box Use the Type drop down box to filter the recorded video files by Continuous Alarm Motion and Manual recordings Left click a time period and press the Play button to review that recorded video file