Home
USER MANUAL
Contents
1. Supply CAN 1 KI Input 12 Voltage QOOQOC Configure your AlbaCombi Connect your laptop to Ethernet port Open the browser navigator preferred Chrome and go to the following address http 192 168 0 50 The first windows that you will see are the FullView page AlbaCOMBI 1200 AP 400 Engine RPM 1 Engine Temperature The gauges that you will see are an example P Alba Combi acu Analogue to NMEA2000 converter SUSLETN 4 1 General Option In this option you can change the Ethernet configuration from the AlbaCombi enable disable the DHCP server and configure the IP address The default configuration is DHCP server disabled and IP address 192 168 0 50 A AlbaCOMBI General Channels Outputs N2K Displays FullViev ICT INFO AlbaCOMBI is a state of the art analogue to NMEA2000 Firmware Version 1 00 converter that covers the most demanding applications Serial Number 05130006 AlbaCOMBI has six OV to 32V channels and another DHCP SERVER additional six channels can be configured in voltage or resistive 0 to 600 ohms mode There are also two RPM inputs available one PTC and one shunt input IP ADDRESS DHCP Disabled AlbaCOMBI will convert all those channels to IP temperature pressure voltage tank levels current Subnet engine status etc You will be able to use that Router information to populate all the available NMEA2000 PGNs EMMI Network S L www albacombi com
2. CONFIGURE DISPLAY select Measurement 1 RPM 1 Pinout 5 Title Port Engine Label Display Type Gauge Zoom View x4 Activate Full View ALARMS MAX Green Zone m SSC 0 7000 0 Yellow Zone 60 5 Red Zone e Select Measurement You will choose any input that you had connected to AlbaCombi e Title Display name you will see underneath the gauge e Label name on the gauge label e Display Type when displaying the information you can select between the following forms o Gauge P Alba Combi atic Analogue to NMEA2000 converter SUS cill o Display Activate Full View If you select this option you will see the parameter in the full screen option from AlbaCombi Alarms zone It is important to set the alarm values as it will define the scale limits on your display Please find hereby examples on how to set these limits GreenZone 0 2500 Yellow Zone 2500 4500 4500 7000 WV 605 Note that the upper limit has to be equal to the Port Engine lower limit of the area above In case you wish only two zones the configuration is as follows GreenZone 0 4500 Yellow Zone 4500 4500 4500 7000 Press Save when the you have finished configuring the display vases Alba Combi ausa Analogue to NMEA2000 converter 4 8 FULL SCREEN OPTION The default page of AlbaCombi will be displayed as shown below All displays that you have configured
3. Ei Input 9 Voltage g D CJ 1 84 GND Input 10 Voltage 3 7 Input 11 Voltage gt g Supply CAN 1 K j Cy Input 12 Voltage Supply CAN 1 Kl G GND Blue NET H White NET L CAN H X Red 5 Positive Feed W Black NET C Common Feed V Lu Alba Combi auus Analogue to NMEA2000 converter 2 2 1 2000 Networks 2000 devices will only communicate with each other when connected to powered and correctly terminated NMEA2000 network All networks need to be powered and terminated correctly to allow data to be transmitted reliably on the network T Pieces are needed to connect each device to the network Additional cable lengths can be used between any of the connectors to extend the length of the network Ensure the NMEA2000 rules for cable length are adhered to Max Length Per drop cable Sum of all drop cables Micro Backbone terminator to terminator Mini Backbone terminator to terminator 2 2 2 NMEA2000 Minimum Network Requirements All NMEA2000 networks require 12 V DC supply In addition a correctly functioning network will require the following components e 1 e 2 Terminating Resistors e 2x T Pieces one per connected device 1x 2000 compatible display All the required network parts can be supplied by Emmi Network S L 7a A
4. The default NMEA address is 9 Note that if you connect two or more AlbaCombi you must change the NMEA address for example you have two AlbaCombi connected on your NMEA network One will have the NMEA Address 9 and other will be configured with NMEA Address 10 If you make any change press Save button and then press Reset yeas Alba Combi ausa Analogue to NMEA2000 converter 4 2 Channel Options In order to configure each connected input please select the channel as shown on the following screen Once selected please configure it AlbaCOMBI x V3 a Q fi D 192 168 0 50 AlbaCOMBI 1 1 Pinout 5 2 RPM 2 Pinout 6 3 PTC1000 P 4 5 Volt Re 10 Shunt Pinout 27 28 Voltage 7 Pinout 29 Voltage 9 8 Pinout 30 16 Voltage 12 Pinout 35 vases Alba Combi arise Analogue to NMEA2000 converter OI Si 4 2 1 RPM Channel You must configure all fields 1 RPM 1 Pinout 5 Save Scaled 4000 0 signal from Engine Physic Variable Rotation Rate Units RPM Limit High Limit Low Filter Level Low Reduction sensor Type Other 400 0 0 0 43 0 83 0 122 0 160 0 201 0 241 0 280 0 RAW name of the channel e Signal from In case of RPM signal the signal is sent by one engine e Physic Variable In case of RPM the only option is Rotation Rate e Units RPM e Limits high an
5. before will be displayed This option can work in parallel to a NMEA display You can view this data in NMEA display installed in your boat and also from any device connected to the same Ethernet network as the AlbaCombi internet based page 2 Temp 8 eile 244 ingne Temp 00 70000 1824 3 7 p N Port Engano A 4 E N 7 10004 Asmotvpreric Press Press on the padlock icon to block unlock the screen In unlock mode you will can move the indicators P Alba Combi Analogue to NMEA2000 converter Before making all connections please follow the next steps 1 Change the state of the switch on Hardware Test Mode Switch 1 on switch 2 off and then press reset button EN ON A0 AN y SFA Ethernet Port 1 Please access the following URL on your PC http 192 168 0 50 2 You will see the Hardware Test Option AlbaCombi Advanced Cont x 3 e 119 943 gt a B G a o o D B o D p o VU V P Alba Combi auus Analogue to NMEA2000 converter 4 iiis If you connect the test board the device will be a hardware test and in your web page you will see
6. humidity 8 3 Engine Parameters Dynamic 2 13 2Hz PGN127508 Battery Status Vibration 13 2 100Hz 7 5 60945 PGN127505 Fluid Level T AGO SR x7 days C 95 HR after two hour salt spray IEC60945 8 12 PGN130314 Actual Pressure Emission IEC60945 9 E M C Status 10 PGN127502 Binary Switch Bank Analogue Inputs
7. on board NMEA N2K multifunction display P Alba Combi Analogue to NMEA2000 converter trol sustem 4 4 4 PGN 127505 Fluid Level Fluid Instance Fluid Type Fluid Level Tank Capacity Reserved FF FPisNT1279505 1yFluid Level Save Instace 0 Capacity cu m 200 Fuel Level Level 5 2 Pinout 21 Active e Instance this is very important field when you have two or more level sensors on your vessel each sensor should be configured with a different instance e Capacity cubic meters You must define the capacity of your tank e Type You can select the type as NMEA standard ndicates Fuel fresh water waste water live well oil and black levels e Level Select the correct input Note enable the Active PGN if you wish to display the parameters in your on board NMEA N2K multifunction display vases Alba Combi aries Analogue to NMEA2000 converter 4 115 f 4 4 5 PGN 130312 Temperature Instance 9 Temperature Source Actual Temperature K Temperature Set Reserved FF 130312 Ti Temperature v GENERIC TEMPER Instace colrca caa Temperatura Actual Value 0 Empty Field Data Active PGN d e Instance this is a very important field if you have two or more temperature sensors on your vessel each sensor must configure with different instances e Source You can select the source type as NMEA standard indicate
8. the checkbox marked if the result has been positive To update the AlbaCombi device Download the last firmware version from www albacombi com and save it on your PC Enter in Installer Mode on your AlbaCombi device Go to http 192 168 0 50 Select the Firmware Update option d i dE AlbaCombi Advanced W 1 C A O 192 168 0 50 Al b C Firrmwar Update 4 Select the xin file saved on step 1 5 Press Update P Alba Combi Analogue to NMEA2000 converter control sustem SPECIFICATIONS IN OUT ELECTRIC SPECIFICATIONS 6 x Resistive 0 to 600 Ohm or 9 18V DC from the NMEA2000 bus Voltage 0 32V 150mA 6 x Voltage 0 32V Equivalent load 3 LEN as per NMEA2000 2 x RPM W signal or magnetic sensor 1 x Precision temperature PTC1000 MECHANICAL SPECIFICATIONS Si 104mm x 86mm x 588mm 1 x 100mV current shunt eH DIN 43880 size 6 Analogue input Weight 230g Mounting DIN Rail Clip EN 50 022 Relay out 2 x Open collector output Cace materal Top PC UL 94 VO Base PPO UL V Ethernet port calibration and monitoring Data in out ENVIROMENTAL SPECIFICATIONS RS232 module programming Protection Class Isolated NMEA2000 EN60529 0 ee 15C to 55 C NMEA2000 Parameter Group Numbers PGN s emperature PGN127488 pcc 25 C to 85 C Engine Parameters Rapid Update 93 40 IEC60945 PGN127489 Relative
9. 4 2 2 PTC1000 Option Scaled 1000 0 signal from Engine Physic Variable Temperature RAW Value 1000 1000 Units Limit High 1000 1000 Low 10 000 Filter Level Low Reduction Sensor Type Other 1000 0 e Signal from you can select if the sensor measures the temperature from the engine battery or it s a general temperature It is important to select the correct sensor because otherwise when configuring the corresponding PGN you won t have the choice to select this parameter for instance if you choose Engine the value will be sent to the NMEA network though the PGN127488 and PGN127489 aignal fram Engine Engine Physic Variable Battery General Temperature e Physic Variable In this case the PTC sensor only works with temperature parameters e Units Select between 9C or K e Limits high and low these limits will be used to set an alarm e Filter Level Please indicate if the level measurement has been made with low medium or high level Sensor Type you have some predefined sensors You can choose a sensor type and make some changes on calibration table If you press on Measured you will see the current value P Alba Combi aua Analogue to NMEA2000 converter SUS cill Mea sured Calibrated You can click on RAW and see the current value or you can write the theoretical value of the sensor output corresponding to the measurement The Calibrated button is used to test if you
10. 7a Alba Combi Analogue to NMEA2000 converter AlbaCombi NMEA2000 Analog Converter USER MANUAL V1 0 2 Rev A woes Alba Combi ausi Analogue to NMEA2000 converter P Alba Combi acu Analogue to NMEA2000 converter Ntrol sustem Contenido PRODUCE OVER VIEW e 5 UI PEE ese 6 1 1 Selecting Mounting LOCATION 6 2 MOUNTING THE ALBACOMBI 7 2 T DIN Fa MOUNTE 7 2 2 Connecting to NMEA2000 7 2 2 1 NMEA2000 NGEPWOTKS vicccrscnsierssiscaccpnnsscoveanetnbannetesuensttiecoawensacecsatbsensescsiaveotieemmeeniiventoies 8 2 2 2 NMEA2000 Minimum Network Requirements eese 8 3 TACHO INPUT _________ _ 9 4 CONFIGURING THE ALBACOMBI 10 al OO U1O stasis _______ 11 rl ie quin Deve bcr __ _________ gt _4 _ 12 __ _ ________ 13 A2 _ _ 6 _ 15 4 2 3 Volt Resistive 17 2 2 SUE osten
11. d Signal from Variable Engine Pressure sid EngineTilt Temperature ______ Voltage Flidflov flow Battery P Alba Combi aua Analogue to NMEA2000 converter e Limits high and low these limits will be used to set an alarm e Filter Level please indicate if the level measurement has been made with low medium or high level Sensor Type You have some predefined sensors You can choose a sensor type and make some changes e Supply Correction Activate Correction Calibration 12 000 Correction Ghannal Voltage 12 You can activate the supply correction using a voltage input Correction Channel Alba Combi aui Analogue to NMEA2000 converter 4 3 Output Option You have 2 relay outputs If you wish to configure alarms 1 Output Relay 1 Pinout I Select Output 1 Output Relay 1 8 2 Output Relay 2 Pinout CONFIGURE OUTPUT Name Fluid Level Alarm 1 Output Type Alarm Alarm Channel 4 YoltResistive 1 Pinout 20 Limit High 90 000 Limit Low 10 000 Activation Rule 1 Higher than limit High e Name please write down the alarm s name e Output Type you have 3 options Manual You can switch on off the relay 2000 allows to act on device connected to the NMEA network when the alarm is activated o Alarm the alarm up and down values are only to be config
12. d Low these limits will be used to set an alarm e Filter Level Please indicate if the level measurement has been made with low medium or high level e Sensor Type you count with some predefined sensors You can choose a sensor type and make some changes If you press on Measure the current value of the input will be shown rw n j A uara 1 A it k Mea sured Calibrated Measured Calibrated 0 0 44000 4000 P Alba Combi audiui Analogue to NMEA2000 converter control sustem You can click on RAW and see the current value or you can write the theoretical value of the sensor output which corresponds to the measurement The Calibrated button is used to test if your calibration table is correct Note that you must click on Save before doing the test Example If you have saved the following calibration table Measured RPM pulse per cycle 600 6000 We assume that the sensor manufacturer indicates these values therefore 3000 rpm we should have a measure of 300 pulses per cycle You can accelerate to see that you have 300 cycles per second by pressing on Raw until that value appears then press Calibrated and see the value if it is about 3000 rpm the calibration table is correct Press SAVE when all changes have been made vases Alba Combi autem Analogue to NMEA2000 converter cro Sustem
13. e only option in the drop down e Physic Variable the only option is current Units mA or A e Limits high and low these limits will be used to set an alarm e Filter Level Indicate if the measures filter has been made with a low medium or high level e Sensor Type You have some predefined sensors You can choose a sensor type and make some changes If you press on Measured you will see the current value You can click on Measured and see the current value or you can write the theoretical value of the sensor output corresponding to the measurement Mea sured Calibrated The Calibrated button is used to test if your calibration table is correct Note that you must click on Save before makingthe test P Alba Combi au Analogue to NMEA2000 converter 4 2 5 Voltage Input A AlbaCOMBI General Channels Outputs N2K Displays FullView 11 Voltage 7 Pin 28 GND 32 Save Engine Temperature 2 c Calibrated Signal from Engine _ Measured Calibrated Physic Variable Temperature 1000 1 07 120 Units eC 90 0 Alarm Limit High Alarm Limit Low 40 000 CALIBRATED Filter Level Low Reduction Sensor Type Sensors Activate Correction Calibration Voc 12 000 MEASURED Correction Channel Voltage 12 Pin 3t e Signal from You can select the parameter that the input will measure engine battery general fluid general temperature general pressure switch bank or general flui
14. ere ner 19 Voltase IBDUE euo iorum c EO 20 m OME dba cube ian x ober tanked 22 Saee Mt A 23 4 4 1 127488 Engine Rapide 23 4 4 2 127489 Engine Parameters 24 4 4 3 PGN 127508 Battery SUAS sepes versus quse oie EU vM ESO Ex SE 25 4 4 4 127505 Fluid Level E eee eee ee 26 4 4 5 130312 Temperature 27 PON 130314 29 AFD fe 5 0 0 NN 30 4 8 FULL SCREEN OPTION MT H 32 5 HARDWARE TEST AND UPDATE DEVICE OPTIONS ssssssnsnssssssssseersssssssreresssssssrrereessssrereresessse 33 OF EEE E 35 P Alba Combi acu Analogue to NMEA2000 converter sustem Company Information EMMI NETWORK 5 1 CALLE DELS FURS 50 46701 VALENCIA SPAIN info emminet com www albacombi com No part of this document may be reproduced in any form without the written permission of the copyright owner The contents of this document are subject to rev
15. inputs Connect the Power to the AlbaCombi 5 Configure the AlbaCombi Engine Alba Combi auc Analogue to NMEA2000 converter 1 INSTALLATION 1 1 Selecting a Mounting Location The following figure shows an example installation This gives an idea of the connections that need to be made to install the AlbaCombi All these connections need to be considered before selecting an installation location 12Vdc 77777777777779779 A i a niooooooooooooooo ELE 7a Alba Combi az Analogue to NMEA2000 converter 2 MOUNTING THE ALBACOMBI UNIT 2 1 DIN Rail Mounting Requirements Atop hat rail type 50 022 or a section rail type EN 50 035 Mounting using a different rail type or an alternative mounting kit may breach the terms and conditions of the guarantee 2 2 Connecting to a NMEA2000 Network f ETHERNET rij Input 1 Resistive or Voltage fag input 2 Resistive or Voltage GND 1 Input 3 Resistive or Voltage RPM 1 3 e GND RPM 2 3 C E Input 4 Resistive or Voltage Open collector GND Aj Input 5 Resistive or Voltage Relay open collector out 1 019 Input 6 Resistive or Voltage Relay open collector out 2 Il SHUNT Temperature PTC1000 e 17 SHUNT GND GND Kilb 2 Input 7 Voltage J Input 8 Voltage S C3
16. ision without notice due to continued progress in methodology design and manufacturing EMMI Network SL shall have no liability for any error or damage of any kind resulting from the use of this document The information provided in this document concerning capacity suitability and performance shall not be considered commercially binding Please note that all capacity figures and dimensioning methods are based on EMMI Network s SL own models of how devices behave in a network The document is intended to be used by professionally trained personnel It is strongly recommended to involve EMMI Network SL in discussions covering the contents of this document Any feedback that may help EMMI Network SL improve the documentation and information methods is welcome Product Disposal Please dispose of this product in accordance with the WEEE Directive The product should be taken to a registered establishment for the disposal of electronic equipment P Alba Combi 50 Analogue to NMEA2000 converter PRODUCT OVERVIEW The new AlbaCombi is a second generation device built following our successful Alba line of converters that translate analogue signals from all over the boat to an NMEA2000 bus The unit has been designed to connect in parallel to an existing gauge so existing instruments can still be used The AlbaCombi can be used to get engine data tank levels alarm status generic pressure and temperature indications fro
17. lba Combi aua Analogue to NMEA2000 converter 3 TACHO INPUT CONNECTIONS V Supply Ignition Coil Connect the negative of the ignition coil to the positive RPM input of the AlbaCombi Connect GND to input GND of the AlbaCombi V Supply Alternator Connect the w connection of the alternator to the positive input of the AlbaCombi input input 5 or AlbaCombi RPM 6 Connect GND input of the alternator to the input 4 V Supply Hall Effect and Electronic Pulse Senders Connect the signal line of the sender to the positive input on the AlbaCombi Connect GND to GND input of the AlbaCombi ees Alba Combi Analogue to NMEA2000 converter 4 CONFIGURING THE ALBACOMBI DEVICE Make all connections See the pin out of your device 40 GND ETHERNET Input 1 Resistive or Voltage tu Input 2 Resistive or Voltage GND Input 3 Resistive or Voltage RPM 1 3 GND RPM 2 2 Input 4 Resistive or Voltage Open collector GND 8 Relay open collector out 1 Relay open collector out 2 Temperature PTC1000 amp 0 Input 5 Resistive or Voltage Input 6 Resistive or Voltage SHUNT SHUNT GND 20000000 GND Kib Input 7 Voltage RS232 TX EE Input 8 Voltage RS232 RX 1 Input 9 Voltage CAN LOW 03 S GND CAN HIGH Input 10 Voltage SHIELD CAN Input 11 Voltage Supply CAN 1
18. m any 4 20mA sensor You get twelve OV to 32V inputs that can be used for anything from reading voltages of batteries to interfacing with any analogue gauges Six channels can be configured to measure resistance from any industry standard engine sensor Also there are two RPM inputs one PTC temperature input one shunt and two relay outputs All twelve resistance and voltage channels have comprehensive calibration that allow you to create an 8 point calibration table or select a predefined industry standard calibration table for most common sensors and gauges The AlbaCombi has an Ethernet port that will allow web based calibration Just connect your laptop to the AlbaCombi via Ethernet and you will get to the calibration and testing page No calibration tools or special interfaces are required This device is future proof and can be upgraded in the field via its ethernet port See the configuration instructions to find which senders and PGNs are supported The instructions can be found on the website at www albacombi com 1 Select mounting location a Ensure the AlbaCombi can mounted in suitable 1 Engine Temp lie Akemator VDC l Battery 1 TitTrim FuelRa te Y Voltage Levels OlPressue Coolant Pressure FR Resistive voltage Inputs Oi Temp Fuel Pressure Temperature location between the NMEA2000 bus and the senders or gauges 2 Connect the AlbaCombi to the NMEA2000 network 3 Connect the Gauge
19. neral Temperature Switth Bank General Fluid Limit Low Engine Limit High e Limits high and low these limits will be used to set an alarm e Filter Level please indicate if the level measurement has been made with low medium or high level Signal from Engine Battery Physic Variable General Fluid General fluid General Temperature General temperature General Pressure General Pressure vases Alba Combi auus Analogue to NMEA2000 converter e Sensor Type You have some predefined sensors You can choose a sensor type and make some changes e Supply Correction only on voltage input not available on resistance mode Activate Correction Calibration Voc 0 000 Correction Yoltaga 12 Pin at You can activate the supply correction using a voltage input Correction Channel vases Alba Combi aise Analogue to NMEA2000 converter cro i SUSTEM 4 2 4 Shunt Input The shunt is a sensor that measures the load or unload current in a battery and it must have the right dimensions to stand the maximum current it it supposed to measure 10 Shunt Pin 27 GND 28 Save Name Battery Current Signal from Battery Physic Variable Current Measured Calibrated Units Alarm Limit High Alarm Limit Low CALIBRATED Filter Level Low Reduction Sensor Type MEASURED e Signal from This parameter can only be obtained from the battery therefore will be th
20. olant Pressure 0 Empty Field Data O Empty Field Data Active The following PGNs which are mentioned in the standard NMEA will be displayed e Instance The instance indicates the engine values port starboard forward etc Oil Pressure if you have configured a pressure input from engine please select it e Engine Temperature If you have configured a temperature sensor from engine please select it e Proceed in the same way with the rest of parameters e Active If you select this option the AlbaCombi will send this information through N2K network and it will be shown on a muntifunction display on board P Alba Combi aua Analogue to NMEA2000 converter trol sustem 4 4 3 PGN 127508 Battery Status Battery Instance Voltage Temperature 12 7208 2 Battery Status Instace Voltage 0 Empty Field Data Current 0 Empty Field Data Case Temperature 0 Empty Field Data Active PGN 2 e Instance this is very important field If you have two or more batteries on your vessel each battery bank should be configured with a different distance e Range 250 for valid position fixes e Voltage Select the input where you have connected the battery voltage on your AlbaCombi e Current Select your shunt input channel e Temperature Select the temperature input from battery bank Note enable the Active PGN if you wish to display the parameters in your
21. r calibration table is correct Note that you must click on Save before make the test Example You has saved the following calibration table Ohms We assume that the sensor manufacturer indicates these values In this way to 70 we must have a measure of 140 Ohms You switch on the engine that you have 140 Ohms you pressing on Measured until that value then press Calibrated and see the value if it is about 70 the calibration table is correct Note that X axis values MEASURE must increase from smallest to largest value Albatross SUS 4 2 3 Volt Resistive Input You have six inputs like this In the Channel screen you will see if the input has been configured on voltage o resistive mode AlbaCOMBI vases Alba Combi Analogue to NMEA2000 converter General Channels Outputs Displays FullView Name Signal frorn Physic Variable Units Alarm Limit High Alarm Limit Low Filter Level Sensor Type e Signal from You can select the parameter that the input will measure engine battery general fluid Fuel Level 1 General Fluid Fluid Level Low Reduction Sensors Save Mea sured Calibrated 100 0 Measured Calibrated 10 0 180 100 Resistence Mode CALIBRATED MEASURED general temperature general pressure switch bank or general fluid signal from General Fluid Physic Variable Battery General Fluid Units Ge
22. s Fm Alba Combi aries Analogue to NMEA2000 converter Source sea Temperature Actual salue Outside Temperature Inside Temperature Active PGN Engine Room Temperature Main Cabine Temperature Live Well Temperature Bait Well Temperature Hefrigeration Temperature Heating system Temperature Dew Point Temperature Wind Chill Apparent Temperature Wind Chill Thearical Temperature Heat Index Temperature Freezer Temperature Generic Source Temperature e Actual Value Select the correct input P Alba Combi ausa Analogue to NMEA2000 converter 4 4 6 PGN 130314 Pressure Instance n9 Pressure Source Pressure Pa Reserved FF GENERIC PRESSURE lnstace SOLUCE Atmospheric Pressure PGN130314 1 Pressure v Save x bul Actual Value 0 Empty Field Data Active PGN C e Instance this is a very important field if you have two or more pressure sensors on your vessel each sensor must configure with different instances e Source You can select the source type as NMEA standard indicates Atmospheric Pressure Atmospheric Pressure Water Pressure steam Pressure Compressed Air Pressure Hydraulic Pressure Generic Source Pressure e Actual Value Select the correct input Lu Alba Combi ausa Analogue to NMEA2000 converter 4 7 Displays Option In this option you will configure the parameters to monitoring in the FullView Option Select the first display to configure it Display 1
23. ured on screen Manual MMEA 2000 Limits high low these limits have already been configured in the Channel Option e Activation Rule You can choose the condition for which the alarm is activated vases Alba Combi aries Analogue to NMEA2000 converter e US 4 4 N2K Option In this section you must configure the PGN to send through the NMEA network 4 4 1 PGN 127488 Engine Rapide Update Engine Speed RPM 7FFFFF PGN12 488 1 Save Instance Instance 1 Part Primary Engine Speed 1 RPM 1 Pinout 5 Engine Boost 0 Empty Field Data Engine Tilt Trim O Empty Field Data Active RPM e Instance The instance indicates the engine port starboard forward etc e Engine Speed if you have a RPM input please select it e Engine Boost if you have configured a pressure input from engine please select it e Tilt trim same as before e Active If you select this option the AlbaCombi will send this information through N2K network and the information will be shown on your multifunction display on board P Alba Combi aua Analogue to NMEA2000 converter trol sustem 4 4 2 PGN 127489 Engine Parameters Dynamic Instance Instance 1 Part Primary Oil Pressure 0 Empty Field Data Oil Temperature O Empty Field Data Engine Temperature 3 PTC10DD Pinout 10 Alternator O Empty Field Data Fuel Hate O Empty Field Data Co
Download Pdf Manuals