Home

Installation Manual Entryway Arbor Kit

image

Contents

1. connectors on both sides of P 3 Three High Panel Reattach the metal connectors to P 3 by securing the bottom two holes of the metal connectors to the top two holes on P 3 so that the metal connectors stick out from the top Slide P 1 One High Topper between the two protruding metal connectors on the top of P A Attach the metal connectors to P 1 Fig 1A Ensure Panels are oriented correctly Fig 1B 2 Secure panels with a S4 2 1 4 Wood Screw the location indicated by the large 1 R E arrow in the direction of the arrow MERERI 3 Secure R Top and Bottom Rails to Panel Assembly with S4 2 1 4 Wood Screws locations indicated by small arrows in the direction of the arrow R Top and Bottom Rails will overhang 1 4 on either side of panel B UR E 4 Repeat until two panel assemblies are created E SIS a ae G0 QO x 4 e I MC NC N 4 3 Fig 1B Filler Strips on Bottom of Panel Oo o Go Oo Fig 1A 2x ONE HIGH _ TOPPER 8x 8 2 1 4 WOOD SCREWS 2x THREE HIGH _ PANEL 2x Lr TOP amp BOTTOM RAIL AT 7 1 4 18 4 CM IF YOU HAVE PURCHASED YM11576 OR YM11577 4X x TOP amp BOTTOM RAIL CUT TO SIZE TO ACCOMMODATE THE ARCH TOPPER STEP 2 ATTACH PANEL CLIPS TO POSTS 3 HIGH PANEL ASSEMBLY Q DE 4 HIGH PANEL ASSEMBLY INSTRUCTION LOCATED ON NEXT PAGE 1 On a flat surface place P 4x4
2. INSTALLATION MANUAL ENTRYWAY ARBOR KIT SINGLE WIDE 3 HIGH amp 4 HIGH PANEL ASSEMBLIES Yardistry North America Toll Free Customer Support 1 888 509 4382 info yardistrystructures com www yardistrystructures com Yardistry Selwood Products Europe Customer Support 44 1284 852569 parts selwoodproducts com www selwoodproducts com IMPORTANT SAFETY NOTICE Yardistry components are intended for privacy decorative and ornamental use only Product is NOT INTENDED for the following A safety barrier to prevent unsupervised access to pools hot tubs spas or ponds Safety railings for elevated platforms or decks As load bearing support for a building structure heavy objects or swings Used in structures that trap wind rain or snow that would create extra load on the product Permanent structures may require a building permit As the purchaser and or installer of this product you are advised to consult local planning zoning and building inspection departments for guidance on applicable building codes and or zoning requirements Wood is NOT flame retardant and will burn Grills fire pits and chimneys are a fire hazard if placed too close to a Yardistry structure Consult user s manual of the grill fire pit or chimney for safe distances from combustible materials During installation follow all safety warnings provided with your tools and use OHSA approved safety gla
3. Post on its side and position Panel Clips in locations indicated in Figure 1 Ensure Panel Clips are oriented as shown in Diagrams 2 Panel Clips should be placed in the centre of the post or the leading edge of the clip should be 1 3 8 or 3 5cm away from the side of the post as shown in Fig 2 3 With Panel Clips in place mark screw holes with a pencil and pre drill holes with a 1 8 drill bit Not provided 4 Secure Panel Clips in locations indicated in figure 1 and 2 with S7 8 x 1 1 2 wood screws 5 Repeat for each post configuration 2 in total lU q U g Front View 56 1 4 142 9cm 40 101 6cm E 10 25 3cm Fig 2 1 1 2 Wood Screws 4X L 4x4 POST 12X PANEL CLIPS 24x 7 8 x 1 1 2 WOOD SCREW STEP 2 ATTACH PANEL CLIPS TO POSTS 4 HIGH PANEL ASSEMBLY 1 On a flat surface place P 4x4 Post on its side and position Panel Clips in locations indicated D Top View E in Figure 1 Ensure Panel Clips are oriented as shown in Diagrams 2 Panel Clips should be placed in the centre of A the post or the leading edge of the clip should be 1 3 8 or 3 5cm away from the side of the post as shown in Fig 2 3 With Panel Clips in place mark screw holes with a pencil and pre drill holes with a 1 8 drill bit Not provided 4 Secure Panel Clips in locations indicated in figure 1 and 2 with S7 8 x 1 1 2 wood screws 5 Repeat for each p
4. g screw injury or damage to the be S or lag to prevent assembly make sure to get help splitting of wood Tighten Bolts Measure Check that assembly is square Square Distance i i Assembly EE This indicates time to tighten bolts but Si A U usc not too tight Do not crush the wood SS This may create splinters and cause proper location structural damage MATERIAL LIST 1 x 3 5 4 x 3 1 x 277 Al 2 2 x 4 x 44 1 2 2 2 x 4x 25 6 5 4 x 3 x 35 3 4 O 3 3 8 2x4 Beam Ends 4 Top and Bottom Rail 20 4 Post Top Connector With 7 16 Hex Bolt Assembly H 12 Panel Clips MATERIAL LIST Note Panel assembly in this instruction is shown as a 3 High X Panel or 3 High Lattice Panel with a 1 High X Topper Depending on kit purchased images may not be accurate Please see front cover for what your final set up should look like Single Wide Entry Arbors 3 High X Arch Assembly YM11576 2 One High X Topper or 3 High X Assembly YM11570 2 One High Lattice Topper or 3 High Lattice X Assembly YM11574 epe gir el 3 High Lattice Assembly YM11572 4 High X Arch Assembly YM11577 4 High X Assembly YM11571 4 High Lattice X Assembly YM11575 P 4 High Lattice Assembly YM11573 4 High Faux Panel YM11606 2 Two Three High X Panel or 2 Two Three High Lattice Panel 4 4x4 Post STEP 1 ASSEMBLE PANELS 1 Remove the upper metal
5. ost configuration 2 in total Fig 1 Front View 75 190 5cm oles and secure with S7 8 x 1 1 2 Wood Screws 4X L 4x4 POST 12X PANEL CLIPS 24x 7 8 x 1 1 2 WOOD SCREW STEP 3 ATTACH PANELS TO POSTS Gy a ti 8 1 Place panel assemblies on posts as shown Fig 1 allowing a 4 gap between the bottom of the post and the bottom edge of the bottom rail on the panel assembly Note Assemble with help of another adult 2 With a 1 8 drill bit predrill holes as shown in figure 2 3 Fasten the panel assembles to the post and Panel Clips with a S5 1 Pan Head Screw provided in location of arrows Fig 1 4 Repeat for each post configuration 4 High Fig 1 X OOOO de x PE TT ET ET ET PT ETE ET TT TT PE ETT EET TTT Ty PTET TET TTT TT PT ETE ET TT TT X Fig 2 Predrill Holes and Fasten S With S5 1 Pan Head Screw 4 1 0 2cm 4 1 O 2cm 12x G5 1 PAN HEAD SCREW STEP 4 LAYOUT POSTS AND A Cic w CONNECTORS 1 Layout Arbor bases in configuration shown in figure 1 Posts must be securely installed to support structure Consult local building codes and ground conditions for required footing design It is recommended the structure be secured to existing stone concrete or deck with the Yardistry Post Base YM21016 or equivalent hardware 2 Install Post Top Connectors with S6 1 1 2 Pan Head Screws provided Fig 2 Ensu
6. re the direction of the Post Top Connector is the same direction as indicated by the arrows in figure 1 Fig 1 Install on a flat and level surface 3 11 1 2 Fig 2 Attach Post Top Connectors with S6 1 1 2 Pan Head Screws 16x Ge 1 1 2 PAN HEAD SCREWS 4X POST TOP CONNECTOR STEP 5 ASSEMBLE ROOF 1 Attach two A 2 x 4 x 44 1 2 Beams to Post Top Connectors with WH 7 16 Hex Bolt as shown in Fig 1 and 1A 2 Centre two B 2 x 4 x 25 Beams in place and attach to Post Top Connectors with WH 7 16 Hex Bolt as shown in Fig 1 and 1A Drill 1 4 Holes for bolts using holes in Post Top Connector as guides 3 Attach eight BE 2 x 4 Beam Ends to Post Top Connectors with WH 7 16 Hex Bolt as shown in Fig 1 and 1A 4 Evenly space apart and secure six C 5 4 x 3 x 35 3 4 Trellis to Beams using 5 4 x 3 Brackets and S1 10 1 Pan Screw Gray as shown in figures 1 and 2 5 4 x 3 Drill 1 4 Holes for bolts using N holes in Post Top Connector as guides 36X 51 10 1 PAN SCREW GRAY 2X 2 X 4X 41 BEAM 6X 5 4 X 3 X 35 1 4 TRELLIS 12X 5 4 X 3 BRACKET 2X 2 X 4X 25 BEAM 32x 7 16 HEX BOLT W NUT 8x z 2X 4 BEAM ENDS
7. sses Some structures may require two or more people to install safely Check for underground utilities before digging or driving stakes into the ground General Information Wood components are manufactured with Cedar C Lanceolata which is protected with factory applied water based stain Knots small checks cracks and weathering are naturally occurring and do not affect the strength of the product Annual application of a water based water repellent sealant or stain will help reduce weathering and checks Warranty Yardistry products are backed by a 5 year limited lifetime warranty from the date of original retail purchase for manufacturing defects and if installed as per manufacturer s installation instructions Patents Pending Tools Required e Tape Measure e 2 Phillips or Robertson Adjustable Wrench e Safety Glasses Carpenters Level ells ol ocrewanver e 1 8 Drill Bit e Adult Helpers Ratchet with extension Carpenters Square 7 16 sockets Pencil e ir a or Cordless Open End Wrench e 1 4 Drill Bit 7 16 e 8 Step Ladder Keys To Assemble Success This identifies information that requires special Check that set or assembly is properly level attention Improper assembly could lead to an before proceeding unsafe or dangerous condition WW Where this is shown 2 or 3 Pre drill 1 8 amp 3 16 Bit eae P p people are required to safely Pre drill a pilot hole complete the step To avoid E 3 before fastenin

Download Pdf Manuals

image

Related Search

Related Contents

Samsung i8000 Black, Red  020-102035-01_LIT GUID START CP2208.book  取扱説明書 - ソニー製品情報  HERMA Address labels Premium A4 199.6x143.5 mm white paper matt 200 pcs.  Untitled - SEM Audio Laboratories  Jne-lag PAGES ou TRESORIER  Analog System Lab Manual 2E prelims  PDF 754 ko  

Copyright © All rights reserved.
Failed to retrieve file