Home

User Manual LON Power Supply LPS133 Art. no

image

Contents

1. according to DIN VDE 0110 Part 1 must be maintained A clearance of at least 4 mm must exist between individual 230 V conductors and the bus cables IDanger to life due to electric current Always deactivate remove the upstream fuses before working on the device 4 Remarks Electrical devices may only be fitted and mounted by a skilled person For planning and building electrical systems the relevant standards guidelines regulations and requirements of the particular country have to be considered In addition to that the device specific instructions have to be considered as well For project planning mounting and commissioning detailed knowledge about the LON technology is assumed Date 19 08 2010 Changes possible Page 4 of 5 LON Power Supply LPS 133 Art no MTN884019 Schneider iP Electric 5 Technical Data Power supply Supply voltage Fuse Network interface Rated output voltage Rated output current Output Relay Nominal input voltage Operating interfaces Reset button Selector switch for termination Operating indicators Bus power LED Connections Mains Network Housing Dimensions Protection class Environmental requirements Operating temperature Max humidity EC guidelines Date 19 08 2010 AC 120 V 60 Hz AC230 V 50 Hz 3 15 AT 230 V internal DC 40 6 42 4 V according to LonWorks specification 1 3 A short circuit and overload proof at 230 V 1 A short circ
2. LON Power Supply LPS 133 Schneider User Manual LON Power Supply LPS133 Art no MTN884019 Content 1 BOS CUO OI saias ssa nais EREE e ao A E e a o 2 2 RUI CLLO 5 s555008 555000555 00acosinoidaso Do sis sacado gd nao isG dado Rs sd sbodE opus go d No idsa a Es d is si dic ap ind 3 3 BONN PERES oa Den RED SRS RR Gu US E ER UEIE DE E E D AR ERR RR ED SEIS TREE ED 3 4 RU AUS settee cece eae RR EE RN ARE O DR OR SAR RED 4 5 WCAG Au Dallas ses chases AEA AEAEE ado densa 5 Date 19 08 2010 Changes possible Page 1 of 5 LON Power Supply LPS 133 Schneider Art no MTN884019 amp Electric IIT ema iii 0 O TTT os ELL AG 230V 1 Description power supply for devices with Link Power Transceivers output current max 1 3 A short circuit and overload proof adjustable bus terminator for free or line topology or without termination monitoring of the output current by relay contact NC supply voltage AC 120 230 V mounting on DIN rail TH 35 according to EN 60 715 width of device approx 180 mm 10 pitch Date 19 08 2010 Changes possible Page 2of5 LON Power Supply LPS 133 Schneider Art no MTN884019 Ef Electric 2 Function The power supply provides the energy for the devices with link power transceiver LPT connected to the corresponding network segment Depending on the energy consumption of the individual nodes up to 64 devices with LPT transceiver can be connected to
3. the power supply The device outputs are short circuit and overload proof The bus power LED assigns the state of the output supply voltage For the network segment connected an adjustable bus terminator for line or free topology networks is integrated The configuration of the termination is done by a DIP switch The DIP switch also provides a configuration to deactivate the termination The Power Supply is equipped with a reset button By pushing this button for a time longer than two seconds the device no longer gives output voltage to the connected LON channel By pushing again for longer than two seconds the device provides the supply voltage for the connected channel The device is equipped with a floating contact normally closed monitoring the output voltage The contact will be open if the output voltage is no longer provided The supply voltage for this contact is not provided by the device 3 Mounting The Power Supply has been designed for mounting on DIN rail TH 35 according to EN 60 715 The 120 230 V mains is connected via pluggable screw type terminals for cross sections up to 1 5 mm and the bus network is connected via pluggable screw type terminals for a cross section up to 1 5 mm The connection to functional earth PE is necessary for the function of the device Date 19 08 2010 Changes possible Page 3 of 5 LON Power Supply LPS 133 Schneider Art no MTN884019 amp Electric Warning Safety clearances
4. uit and overload proof at 120 V normally closed contact will open when the output voltage breaks AC DC 42 V SELV by pushing for a time longer than 2 seconds the output voltage can be switched ON or OFF All OFF no termination 1 and 2 ON 3 and 4 OFF termination for bus topology 110 Ohm 1 2 and 4 OFF 3 ON termination for free topology 55 Ohm lit bus power all right off no bus power Flashes 2x bus power overload or short circuit retry of reset Flashes 3x device is overheated Fast flashing reset button was pressed screw type terminals for cross sections of up to 1 5 mm pluggable screw type terminals for cross sections of up to 1 5 mm 90 x 180 x 65 mm H x Wx D 10 pitch IP 20 5 C 40 C 5 93 relative humidity without moisture condensation Low voltage guideline 2006 95 EEC EMC guideline 2004 108 EEC Changes possible Page 5 of 5

Download Pdf Manuals

image

Related Search

Related Contents

LG DN798 User's Manual  Toshiba Chromebook CB30-B-104  HD 10/16-4 Cage  Keysight Technologies Digital Multimeters    Ridgestone Express Internet Banking and  Gladiator GAWP082PBY Instructions / Assembly  COBY electronic CX-CD331 User's Manual  Panasg"ーc 5』七篇ル通路= 導灯 (兼用器具) 施工説明書  88/88 - Support Sagemcom  

Copyright © All rights reserved.
Failed to retrieve file