Home
USER`S MANUAL - DAVI Y CIA, S.L.
Contents
1. purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recommended to keep the original packaging Following expiry of the guarantee period all services requested will be dealt with by our specialist technicians at the user s expense 10 CE DECLARATION OF CONFORMITY CE DECLARATION OF CONFORMITY FABRICANTE PRODUCTO DAVI amp CIA S L PRODUCT MANUFACTURER DIRECCI N C Murcia 35 Nave G ADDRESS Pol gono Industrial Can Calder n E08830 Sant Boi de Llobregat BARCELONA ESPANA DECLARAN BAJO SU RESPONSABILIDAD QUE EL PRODUCTO DECLARE UNDER THEIR RESPONSIBILITY THAT THE PRODUCT Marca DERMOPRIME Brand Nombre dpone Name Tipo EQUIPO ELECTRONICO Type Electronic equipment Finalidad Prevista Equipo analizador de piel Intended Use Skin analyzer equipment CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES EC Directive 2004 108 EC Directiva de Compatibilidad Electromagnetica Electromagnetic Compatibility Directive EC Directive 2006 95 EC Directiva de Baja tension Low Voltage Directive FECHA 01 de Junio de 2009 DATE 01 June 2009 Nombre J Masana Name Firmado Cargo
2. in a few minutes To switch off the equipment press the button once again and the dermoprime software and the Operating System will automatically close The software application runs under Microsoft Windows Operating System automatically starting up Windows without having to touch the Operating System 4 LOCATION AND ENVIRONMENT The appliance should be kept well away from vibrations and sources of intense heat such as heaters Stand the appliance on a flat level surface where it is firmly supported 5 OPERATION o Please refer to the software manual 6 POLARIZATION OF THE CAMERA The dermoprime system uses a single device of integrated lenses that can explore 3 different skin layers thanks to the X60 Triple mode lens with automatic polarization These three images of the same area have been captured with the three modes of the X60 lens NORMAL 1 NORMAL 2 POLARIZED Analyzes Analyzes Analyzes e PORES e WRINKLES e SPOTS e UNIFORMITY e ELASTICITY 7 MAINTENANCE AND CLEANING The only maintenance operation that can be performed by non qualified personnel is changing the paper and cleaning the screen Never attempt to carry out any repairs yourself In the event of a fault contact the Technical Assistance Service If the power cord is damaged it must be repla
3. Function DAVI 8 CIA 10 DAVIS CIA C Murcia 35 Nave G Pol industrial Can Calder n E 08830 Sant Boi de Llobregat Barcelona Spain Tel 34 93 654 32 32 Fax 3493 654 16 62 info davicia com www davicia com 11
4. ced by the Technical Assistance Service or qualified personnel in order to prevent any malfunction and make sure that the appliance is not dangerous Use only a soft slightly damp cloth to clean the appliance Never use petrol thinner or any other similar solvent product To prevent any damage never clean the camera lens 7 1 SCREEN CLEANING Clean the touch screen regularly using non abrasive cleansing towelettes specific for this purpose Wash your hands frequently while using the equipment 7 2 PAPER ROLL CHANGE To change the paper roll lift the printer cover pull the printer towards you on its rails and insert a new roll as shown the figure In this case it must be used the paper roll that is 40m long and the 86mm shaft When inserting the paper the printer will automatically pull it and cut it To use the 175m long paper roll it must be placed through the maintenance lid To do so use the 112mm shaft and place it in the fixed guides in the equipment interior 7 3 EQUIPMENT DISPOSAL All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of the equipment will help prevent potential negative consequences f
5. opone USER S MANUAL MA11 02 A 14 12 2010 www davicia com DAVIS CIA INDEX ee a ee DESCRIPTION PART LIST STARTING UP LOCATION AND ENVIRONMENT OPERATION POLARIZATION OF THE CAMERA MAINTENANCE AND CLEANING 7 1 Screen cleaning 7 2 Paper roll change 7 3 Equipment disposal TECHNICAL SPECIFICATIONS 8 1 Camera GUARANTEE CE DECLARATION OF CONFORMITY Q O MD O0W00 1 I ODD MH HW 1 DESCRIPTION Ix El gt y 1 Coin slot 2 Chip card slot 3 Access cover for changing paper 4 Coin box 5 Coin return 6 Button for opening the coin box 7 Skin sensor camera 8 ON OFF Button 9 Power supply Fuse 10 Maintenance access lid 2 PART LIST dpone EQUIPMENT d LA Set of keys to access the maintenance lid and the coin Plastic key ring x1 box x2 Paper roll x8 Power supply cable x1 dermo prime Face cleansing towelette Teallita de higiene facia 1 tameletis MP CAM Sta Cleansing towelettes x200 Acrylic towelette dispenser x1 Includes software manual Paper roll shafts x2 sizes dermo prime DAVI SMART CARD meer A dovicia 18 meu Jovicio on Chip card x50 Screws to mount the equipment on its desk x4 3 STARTING UP o Connect the equipment to the power supply 9 o Press the button located in the back side to the left 8 o The screen will turn on and the software will launch
6. or the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment 8 TECHNICAL SPECIFICATIONS DPONE Manufacturer DAVI amp CIA C Murcia 35 nave G E08830 Sant Boi de Llobregat Barcelona SPAIN 12 1 Touch screen 4 3 800 x 600 pixels 23 kg aprox Max external dimensions 460x335x530 mm Power supply 115 240 Vac 50 60 Hz n operation 80 VA max In operation Temperature 10 Cat 40 C Humidity 30 a75 Print Thermal printer 8 points mm Speed 180 mm s Photocell detection of end of paper 80 mm 40m 175m EC applicable Directives Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC 8 1 CAMERA NTSC 1 4 SONY Super HAD CCD 2 1 Internal 480TV Lines Horizontal 410 000 1 0Vp p Composite 750hm USB 2 0 Live Capturer TPL mode Normal mode 0 a 470 000 X1 Lens X60 triple Lens X10 Lens Disinfection with UV Lamp Automatic White Balance 0 1 Lux in F2 0 14 F 122 F 10 C 50 C Within 90 RH 86 W X 99 5 H X 245 L mm 9 GUARANTEE We provide a 1 year guarantee from the date of purchase The guarantee covers manufacturing defects or defects occurring as a result of normal use and operation It excludes all removable parts such as batteries wires power supply devices etc Faults falling within the guarantee period shall be rectified free of charge upon presentation of the
Download Pdf Manuals
Related Search
Related Contents
SIMOCAP Manual de Usuario Essais en place et en laboratoire sur sols cohérents Comparaisons Cardinal Gates XTG User's Manual 超高速昇温炉底昇降炉 FUBシリーズ Ralph Dux STRAHL User Manual IPP 10/30 September, 2006 Samsung VC-8614V User Manual HP Output Finishing Devices Service Manual Paso Uno Paso Dos Copyright © All rights reserved.
Failed to retrieve file