Home
Datasheet
Contents
1. CAT III instrument and included accessories 600 V CAT III instrument and included accessories Battery installed 4 hr Ni MH BP190 7 hr Ni MH 5 hr Ni Cd Line power Adapter battery charger included Size cm 25 6 x 16 9 x 6 4 cm 23 2 x 11 5 x 5 0 cm Weight 2 kg 1 2 kg PC and Printer interface Using optional Optically Isolated RS 232 adapter cable Warranty 3 years on main instrument 1 year on the standard accessories Fluke Corporation P O Box 9090 Everett WA USA 98206 Fluke Europe B V A P O Box 1186 Ordering Information 5602 BD Eindhoven The Netherlands For more information call Fluke 199C Color ScopeMeter 200 MHz 2 5 GS s R me os aie asa Fluke 199C S Color ScopeMeter 200 MHz 2 5 GS s SCC190 In Europe M East Africa 31 0 40 2 675 200 Fluke 196C Color ScopeMeter 100 MHz 1 GS s or Fax 31 0 40 2 675 222 Fluke 196C S Color ScopeMeter 100 MHz 1GS s SCC190 In For 1908 890 6560 Fluke 199B ScopeMeter 200 MHz 2 5 GS s rave as Fluke 199B S ScopeMeter 200 MEZ 2 5 GS s SCC190 Ste rire ea ee ee Fluke 196B ScopeMeter 100 MHz 1 GS s Fluke 196B S ScopeMeter 100 MHz 1 GS s SCC190 Visit us on the world wide web at Fluke 192B ScopeMeter 60 MHz 500 MS s Fluke 192B S ScopeMeter 60 MHz 500 MS s SCC190 http I www fluke com Fluke 124 Industrial ScopeMeter 40 MHz Fluke UK Ltd Fluke 124 S Industrial ScopeMeter 40
2. III Maximum voltage between input and reference lead Maximum input voltage using VPS40 Probe 600 V CAT III 1000 V CAT II Maximum voltage between probe tip input and reference lead Floating voltage 600V CAT III Maximum voltage between earth ground and any terminal signal input or reference lead Maximum voltage between reference leads ENVIRONMENTAL Operating Temperature Storage temperature Humidity Maximum operating altitude Maximum storage altitude Electro Magnetic Compatibility EMC Instrument has common grounds connected via selfrecovering fault protection For different ground potential measurements between inputs use DP 120 differential voltage probe 0 C to 50 C 20 C to 60 C 10 C to 30 C 95 RH non condensing 30 C to 40 C 75 RH non condensing 40 C to 50 C 45 RH non condensing 2 000m 6 500 feet 3 000m 10 000 feet voltages lt 400V 12 km 40 000 feet Emission EN50081 1 EN55022 and EN60555 2 Immunity EN50082 2 IEC 1000 4 2 3 4 5 OPTICALLY ISOLATED PC PRINTER INTERFACE To printer To PC WARRANTY Supports HP Laserjet Deskjet Epson FX LQ and postscript printers via optional PAC91 Transfer instrument settings screen images and data compatible with FlukeView software for Windows via optional PM9080 3 years parts and labor on main instrument 1 year on accessories FLUKE o FlukeView ScopeMeter Software Pukeview ScopeMeter s
3. 100x Up to 2 dual input ScopeRecord waveforms can be saved for later recall and analysis Single or dual input electronic paperless chart recorder Plots displays and stores meter and scope measurements Input A Input B or DMM input 18 000 points record per input Per record point a minimum a maximum and an average value plus a date and timestamp are stored 5 s div to 30 min div 5 min div to 48 hr div Up to 22 days with a resolution of 1 minute Continuous roll for the duration of the full recordable timespan 5 measurements per second or more Time from start time of day Up to 64x zoom Up to 2 TrendPlot recordings can be saved for later recall and analysis CURSOR MEASUREMENTS ALL RECORDER MODES Source Dual vertical lines Single vertical line Input A B or DMM input Min Max or Average voltage Time between Cursors Min Max or Average voltage Absolute date and time or time from start Technical Datasheet Fluke ScopeMeters 3 GENERAL SPECIFICATIONS INPUT VOLTAGE RATINGS Maximum probe voltage Floating voltage 1 000V CAT II 600V CAT III Maximum voltage between 10 1 probe tip VPS200 and reference lead 1 000V CAT II 600V CAT III Maximum voltage between earth ground and any terminal signal input or shielding Independently isolated inputs 1 000V CAT II 600V CAT III Maximum voltage on BNC input directly input A or B Maximum voltage on meter input Maximum voltage between
4. 60 Hz 1 kHz 2 5 15 counts 20 kHz 1 MHz 5 20 counts 500mV 5V 50V 500V 1 250V 5 000 counts DC 60 Hz 1 10 counts 60 Hz 1 kHz 2 5 15 counts 20 kHz 1 MHz 5 20 counts 5009 5kQ 50kQ 500kQ 5M9 30MQ 5 000 counts Accuracy 0 6 of reading 5 counts CAPACITANCE Ranges 50 nF 500pF Max Resolution 5 000 counts Accuracy 2 of reading 10 counts OTHER METER FUNCTIONS Frequency Up to 70 MHz Fluke 124 and up to 40 MHz Fluke 123 Continuity Beeper on lt 30Q Diode test Up to 2 8V Amps Amp DC Amp AC Amp AC DC Temperature C F Number of inputs Input impedance Advanced meter functions using an optional current clamp or shunt Scaling factors 0 1 mV Amp 100 V Amp With optional accessories Scale factors 1 mV C or 1 mV F 2 IMQ 1 10 pF 2 pF Auto manual ranging TouchHold Relative measurements zero reference TrendPlot recording Technical Datasheet Fluke ScopeMeters 5 RECORDER MODE TRENDPLOT RECORDING Source and display Range Dual input electronic paperless chart recorder Plots and displays the actual mini mum maximum and average of any measure ment Input A Input A and B 15 s div till 2 days per division automatic Recorded timespan Up to 16 days with a resolution of 1 5 hours Recording mode Continuous with automatic vertical scaling and horizontal time compression Measurement speed 2 5 measuremen
5. 6C 199B 196B 192B Fluke 123 124 Rechargeable BP190 BP120 Fluke 123 battery pack installed BP 130 Fluke 124 Line voltage adapter BC190 PM8907 Battery charger Voltage probes 10 1 voltage probe VPS200 including STL120 Shielded Test lead set 1 set red 1 set grey and accessories hook clip ground lead with hook clip ground lead with mini alligator clip 4 mm add on probe tip ground lead to 4 mm banana plug VPS40 high impedance 10 1 probe 40 MHz 1 black included with Fluke 124 only HC120 hook clips ground leads with mini alligator clips AC120 alligator clips BB120 BNC to Shielded banana adapter Multimeter testleads TL75 Hard Point testlead set lred 1 black TL75 Hard Point test lead 1 black User manual 10 language versions on CD ROM Getting Started booklet included with instrument 15 language versions on CD ROM Getting Started booklet included with instrument Next to the above standard accessories Fluke offers a wide range of optional accessories like temperature probes current clamps high voltage probes cables adapters and carrying cases to further assist you in your job See the Fluke web site or contact your distributor for details CC190 and SCC120 Software Case Cable kits The Fluke ScopeMeters are connected to a PC using an optically isolated RS 232 interface cable PM9080 for your safety Software and cable can be ordered seperately or as pa
6. FLUKE RY SS and ScopeMeter 120 Series Technical Data c npecti IEW ScopeMeter 190 Series Speed performance and analysis power For demanding applications the ScopeMeter 190C and 190B Series high performance oscilloscopes offer specifications usually found on top end bench instruments They re ideal for engineers who need the full capabilities of a high performance scope in a handheld battery powered instrument Dual input 200 100 or 60 MHz bandwidth Up to 2 5 GS s real time sampling per input Choice between a high resolution Color 190C or Black and White 190B display High waveform resolution of 3000 datapoints per channel Digital Persistence for analyzing complex dynamic waveforms like on an analog scope 190C Series Fast display update rate for seeing dynamic behavior instantaneously Connect and View automatic triggering a full Range of manual trigger modes plus external triggering Frequency Spectrum using FFT analysis 190C 27 500 points per input record length using ScopeRecord mode Automatic capture and replay of 100 screens Four hours rechargeable NiMH battery pack 1 000V CAT II and 600V CAT III safety certified Up to 1 000V independently floating isolated inputs AAAA AKA AS A SS SN ANAA ScopeMeter 120 Series Three in one simplicity The compact ScopeMeter 120 Series is the rugged solution for industrial troubleshooting and inst
7. MHz SCC120 kit 52 Hurricane Way Fluke 123 Industrial ScopeMeter 20 MHz Norwich Fluke 123 S Industrial ScopeMeter 20 MHz SCC120 kit NRG 6JB SCC 190 FlukeView Software Cable Case 190 Series United Kingdom SCC120 FlukeView Software Cable Case 120 Series Tel 0207 942 0700 PM9080 Optically Isolated RS 232 adapter cable Pax 0207 942 0701 SW90W FlukeView ScopeMeter Software for Windows Sue si ese Visit us on the world wide web at e ScopeMeter test tools come standard with a complete accessory package including line voltage adapter and battery pack installed ScopeMeter 190B and 190C Series come with probes probe accessories and multimeter test leads http www fluke co uk e SCC kit includes Hard shell carrying case optically isolated RS 232 interface cable and FlukeView for Windows software Copyright 2004 Fluke Corporation All rights reserved Data subject to change without notice ScopeMeter and FlukeView are registered trademarks of Fluke Corporation Windows is a registered trademark of Microsoft Corporation Printed in the Netherlands 03 2004 Pub_ID 10705 eng Rev 01
8. allation applications It s a truly integrated test tool with oscilloscope multimeter and paperless recorder in one affordable easy to use instrument Find fast answers to problems in machinery instrumentation control and power systems W A dual input 40 MHz or 20 MHz digital oscilloscope M Two 5 000 counts true ms digital multimeters Cursor measurements Fluke 124 A dual input TrendPlot recorder Connect and View trigger simplicity for hands off operation Shielded test leads for oscilloscope resistance continuity and capacitance measurements Up to seven hours battery operation 600V CAT III safety certified Optically isolated RS 232 interface NAAN NS NNS Rugged compact case Technical Specifications 190C and 190B Series OSCILLOSCOPE MODE VERTICAL DEFLECTION Fluke 199C Fluke 196C Fluke 192B Fluke 199B Fluke 196B Bandwidth 200 MHz 100 MHz 60 MHz Rise time 1 7 ns 3 5 ns 5 8 ns Bandwidth limiter User selectable 10 kHz 20 MHz or off Number of inputs 2 plus external trigger All inputs isolated from each other and ground Input coupling AC or DC with ground level indicator Input sensitivity 2 mV div to 100 V div Fluke 190C Series 5 mV div to 100 V div Fluke 190B Series Normal Invert On both input channels switched separately Variable Attenuator Variable Gain on input channel A Input voltage 1000V CAT II 600 V CAT III rat
9. any terminal of one input or probe VPS200 and any other terminal of another input or probe VPS200 300V CAT III 1 000V CAT II 600V CAT III MEMORY SAVE AND RECALL Scope memories Recorder memories REAL TIME CLOCK 10 memory locations that each can contain two waveforms plus corresponding setup 2 memory locations that each can contain 100 captured dual input scope screens or a dual input ScopeRecord 27 500 Min Max pairs per input or a dual input Trendplot 18 000 min max pairs Time and date stamp for ScopeRecord 100 captured screens and TrendPlots CASE Design Rugged shock proof with integrated protective holster Drip and dust proof IP51 according to IEC529 Shock and Vibration Shock 30g Vibration sinusoidal 3g according to MIL PRF 28800F Class 2 Display Size 115 2 x 86 4 mm 4 54 x 3 4 inches Resolution 320 x 240 pixels Contrast and brightness User adjustable temperature compensated Fluke 190C Fluke 190B DISPLAY Bright full color LCD Bright LCD with backlight with backlight BRIGHTNESS 80 Cd m typ using 125 Cd m typ using power adapter power adapter MECHANICAL DATA Size 256 x 169 x 64 mm 10 1 x 6 6 x 2 5 inches Weight 2 kg 4 4 lbs POWER Line power Country specific line voltage adapter battery charger included Battery power Rechargeable NiMH installed Battery operating time 4 hours Battery charging time 4 hours Battery power saving functions Auto powe
10. by sit mode and will capture 100 events Manual or continuous replay Displays the captured 100 screens as a live animation or under manual control Each screen has date and time stamp Up to 2 sets of 100 screens each can be saved for later recall and analysis FFT FREQUENCY SPECTRUM ANALYSIS 190C only Window Automatic Window Vertical Scale Frequency Axis Shows frequency content of oscilloscope waveform using Fast Fourier Transform Automatic Hamming Henning or None Digitally re samples acquired waveform to get optimum frequency resolution in FFT resultant Linear Logarithmic in volts Logarithmic frequency range automatically set as function of timebase range of oscilloscope WAVEFORM COMPARE AND PASS FAIL TESTING Waveform compare Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms Reference is derived from an acquired waveform and can be modified in the ScopeMeter or externally using FlukeView Software Pass Fail Testing 199C 196C In waveform compare mode the Color AUTOMATIC SCOPE MEASUREMENTS ScopeMeter can be set up to store only matching Pass or only non matching Fail acquired waveforms in the replay memory bank for further analysis Vdc Vac rms Vac dc Vpeak max Vpeak min Vpeak to peak Aac Adc Aac dc frequency Hz risetime falltime power factor Watts VA VA reactive phase pulsewidth pos neg du
11. e test Up to 2 8V Amps Adc Aac Aac dc using an optional current Temperature C F Input impedance Advanced meter functions clamp or shunt Scaling factors 0 1 mV A 100 V A With optional accessories Scale factors 1 C mV or 1 F mV 1 MQ 1 10 pF 2 pF Auto manual ranging relative measurements Zero reference TrendPlot recording FLUKE o RECORDER MODE SCOPE RECORD Dual input waveform storage mode ROLL MODE Source and display Input A Input B Dual Memory depth 27 500 points per input Each point consist of Min Max pair Min Max values Min Max values are measured at high sample rate ensuring capture and display of glitches Time base range 5 ms div to 1 min div 2 min div Recorded timespan 6 sec to 24 hr 48 hr Glitch capture 50 ns 250 ns Sample rate 20 MS s 4 MS s Resolution 200 psec to 2 sec 4 8 sec Recording modes Stop on Trigger through External Horizontal scale Zoom Memory TRENDPLOT RECORDING Source and display Memory depth Ranges normal view in view all mode overview of total record Recorded timespan Recording mode Measurement speed Horizontal scale Zoom Memory Single sweep continuous roll Start on Trigger through external Stop on Trigger through external ScopeRecord mode can be stopped by an individual trigger event or by an interruption of a repetitive trigger signal Time from start time of day Up to
12. ed See general specifications for further details Vertical resolution 8 bit Accuracy 1 5 of reading 0 04 x range div Input impedance 1 MQ 1 15 pF 2 pF HORIZONTAL Fluke 199C Fluke 196C Fluke 192B Fluke 199B Fluke 196B Maximum real time 2 5 GS s 1 GS s 500 MS s sample rate Number of digitizers 2 2 2 Time base range 5 ns div 10 ns div to 5 s div to 5 s div Maximum record length 3000 points per input in Scope mode 27 500 points per input in ScopeRecord roll mode 5 ms div 2 min div Accuracy 0 01 of reading 1 pixel Glitch capture 50 nsec 5 psec div to 1 min div DISPLAY AND ACQUISITION Fluke 190C Fluke 190B Display 144 mm 144 mm Full Color LCD Monochrome LCD Display modes Input A Input B dual average Replay Persistence modes Digital Persistence Persistence short medium on off long infinite Visible screen width Waveform Mathematics Acquisition modes TRIGGER AND DELAY Source Modes Connect and View Video triggering Pulse width triggering 12 divisions in scope mode A B A B A B all with user selectable scaling of resultant A versus B X Y mode Frequency Spectrum using FFT analysis 190C only Normal auto single shot ScopeRecord roll glitch capture waveform compare waveform compare with automatic Pass Fail testing in 199C and 196C only Input A input B external trigger input All input references is
13. line select Up to 10 divisions pre trigger view VDC VAC VAC DC Vpeak max Vpeak min Vpeak to peak frequen cy Hz positive pulse width negati ve pulse width positive duty cycle negative duty cycle Amp AC Amp DC Amp AC DC Phase Temperature C Temperature F dBV dBm into 50Q and 600Q Amps C or F with optional probes CURSOR MEASUREMENTS 124 only Sources Modes Measurements Single vertical line Dual vertical lines Dual horizontal lines Accuracy DUAL INPUT METER Input A Input B Single or dual vertical cursor dual horizontal cursor rise or falltime Average min value max value time from start of recording in roll mode AV at markers time between cursors 1 T between cursors in Hz High low or AV readout rise and falltime transition time O level 100 level with markers at 10 and 90 As oscilloscope The specified accuracy is valid over the temperature range 18 C to 28 C 65 F to 82 F Add 10 of specified accuracy for each degree C below 18 C or above 28 C Max meter bandwidth VDC Ranges Max Resolution Accuracy VAC RMS Ranges Max Resolution Accuracy VAC DC TRUE RMS Ranges Max Resolution Accuracy OHMS Ranges Max Resolution 40 MHz for Fluke 124 and 20 MHz for Fluke 123 500mV 5V 50V 500V 1 250V 5 000 counts 0 5 5 counts 500mV 5V 50V 500V 1 250V 5 000 counts 1 Hz 60 Hz 1 10 counts
14. nces and ground isolated inputs Input sensitivity 2 mV div 100 V div 5 mV div 100 V div 5 mV div 500 V div Glitch capture Up to 3 ns using Pulse Width triggering 40 ns 50 ns peak detect at 5 ps div to 1 min div Timebase range in Scope mode 5 ns div to 2 min div 10 ns div 10 ns div 20 ns div 2 min div 1 min div 1 min div Trigger types Connect and View Free Run Single Shot Edge Delay Video Frame Video Line Connect and View Free Run Selectable pulse width and External Single Shot Edge Video Dual Slope trigger and Event trigger n cycle Scope Measurements 7 cursors measurements 30 automatic measurements cursors 26 automatic Automatic Vrms and watts measurement on 26 automatic measurements cursor limited part of waveform measurements Waveform Mathematics A B A B A x B A versus B X Y mode giving Lissajous diagrams Frequency Spectrum FFT Scope Record Trigger modes Start on Trigger Stop on Trigger Capture last 100 screens Automatic with Replay capability Dual input TrendPlot Yes with Cursors and Zoom Memory for screens set ups 10 screens and set ups 5 more memories are made available upon registration of the ScopeMeter Memory for recordings Two each can store 100 scope screens a ScopeRecord or a TrendPlot True RMS multimeter 5000 counts Volts Amps Ohms Continuity Diode Temp Safety certified EN61010 1 1000 V CAT II 600 V
15. oftware helps you get more out of your ScopeMeter Store instrument s screen copies on the PC in color with Fluke 190C Series only or in black amp white Copy screen images into your reports and documentation Capture and store waveform data from your ScopeMeter on your PC Create and archive waveform references for automatic Fluke 190C Series or visual Fluke 190B and 190C Series comparison Includes waveform analysis e g FFT spectrum analysis Copy waveform data into your spreadsheet for detailed analysis Use cursors for parameter measurement Extended recording of up to four user selected measurements help you monitor and analyze slow moving signals and related events Logging of other readings directly into other application programs eg spreadsheet Add user text to instrument setups and send these to the instrument for operator reference and instructions Capture complete Replay sequence into the PC for further analysis and documentation English French and German versions included on a single CD ROM System requirements Supported Instruments Full support for Fluke 199C 199B 199 196C 196B 196 192B 192 124 and 123 Pentium 90 or better CD ROM drive Windows 95 98 Me NT 4 0 2000 XP One free RS 232 port PM9080 Optically isolated RS232 adapter cable available separately or included in SCC120 SCC190 kit and in ScopeMeter S versions Accessories Standard Accessories Fluke 199C 19
16. olated from each other and from ground Automatic Connect and View free run single shot edge delay video video line selectable pulsewidth dual slope 190C only N cycle 190C only Advanced automatic triggering that recognizes signal patterns automatically sets up and conti nuously adjusts triggering time base and ampli tude Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals Can be switched off if so desired NTSC PAL PAL SECAM Includes field 1 field 2 and line select Pulse width qualified by time Allows for trigge ring lt t gt t t t where t is selectable in Technical Datasheet Fluke ScopeMeters 2 Time delay Dual slope triggering N cycle triggering minimal steps of 0 01 div or 50 nsec 1 full screen of pre trigger view or up to 100 screens 1200 divisions of post trigger delay Both rising and falling transitions when crossing the trigger level initiate an acquisition 190C only Triggers on N th occurrence of a trigger event N to be set in the range 2 to 99 190C only AUTOMATIC CAPTURE OF The instrument ALWAYS memorizes the last 100 SCREENS Replay Replay storage 100 screens no user setup required When an anomaly occurs on screen the REPLAY button can be pressed to review the full screen sequence over and over Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in ba
17. r down with adjustable power down time On screen battery power indicator Technical Datasheet Fluke ScopeMeters 4 SAFETY Compliance ENVIRONMENTAL Operating temperature Storage temperature Humidity Maximum operating altitude Maximum storage altitude Electro Magnetic Compatibility EMC EN61010 1 2nd edition Pollution Degree 2 UL3111 1 CAN CSA C22 2 No 1010 1 ANSI ISA 82 01 0 C to 50 C 20 C to 60 C 10 C to 30 C 95 RH non condensing 30 C to 40 C 75 RH non condensing 40 C to 50 C 45 RH non condensing 3 000 m 10 000 feet 12 km 40 000 feet EN 61326 1 for emission and immunity OPTICALLY ISOLATED PC PRINTER INTERFACE To printer To PC WARRANTY Supports HP Laserjet DeskJet Epson FX LQ Seiko DPU 414 and Postscript printers via optional PAC 91 Transfer instrument settings screen images and waveform data compatible with FlukeView software for Windows via optional PM9080 3 years parts and labor on main instrument 1 year on accessories FLUKE o Technical Specifications ScopeMeter 120 Series OSCILLOSCOPE MODE VERTICAL DEFLECTION Bandwidth and risetime Fluke 124 Fluke 123 e with VPS40 probes 40 MHz 20 MHz input A and B directly 40 MHz 20 MHz e with STL120 Shielded Test Leads 12 5 MHz 12 5 MHz Instrument risetime input directly 8 75 ns 17 5 ns Number of inputs Input coupling Input sensitivity Vertical resolution Accu
18. racy Input impedance HORIZONTAL Maximum sample rate Number of digitizers Time base range Maximum record length 2 AC DC with ground level indicator 5 mV 500 V div with included VPS40 Fluke 124 and STL120 shielded test leads measure up to 600Vmns CAT II 8 bit 2 of reading 0 05 x range div 1 MQ 1 225 pF with STL120 shielded test leads 1 MQ 1 20 pF 3 pF with BB120 5 MQ 1 15 5 pF with VPS40 10 1 Voltage probe Fluke 124 2 5 GS s for repetitive signals 25 MS s for single shot Fluke 123 1 25 GS s for repetitive signals 25 MS s for single shot 2 10 ns div to 1 min div Fluke 124 20 ns div to 1 min div Fluke 123 512 Min Max points per input Accuracy 0 1 of reading 1 pixel Glitch detect 40 ns DISPLAY AND ACQUISITION Display modes Input A input A and B envelope smooth Acquisition modes Normal single shot roll glitch capture always on TRIGGER AND DELAY Source Input A input B external via optional ITP 120 Modes Automatic Connect and View Connect and View Video triggering Time delay MEASUREMENTS Free Run Edge Single Shot Video Video Line Advanced automatic triggering that recognizes signal patterns and auto matically sets up and continuously adjusts triggering time base and amplitude Automatically displays stable pictures of complex and dynamic signals like motor drive and control signals NTSC PAL PAL SECAM Includes
19. rt of a special value kit the SCC190 kit or the SCC 120 kit Each of these include a protective hard shell carrying case model depending on the ScopeMeter model for safe and convenient storage of instrument and accessories the FlukeView ScopeMeter Software for Windows and the PM9080 interface cable Technical Datasheet Fluke ScopeMeters 7 FLUKE Selection Table Color ScopeMeter ScopeMeter ScopeMeter 190C Series 190B Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 124 Fluke 123 Bandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHz Max real time sample rate 2 5 GS s 1 GS s 2 5 GS s 1 GS s 500 MS s 25 MS s Max equivalent time sample rate 2 5 GS s 1 25 GS s Display 14 4 cm Full Color LCD 14 4 cm Monochrome LCD 10 2 cm Monochrome LCD Digital Persistence Yes gives analog oscilloscope like waveform decay user selectable Envelope mode Yes Yes Waveform Compare Visual Reference Visual Reference and Automatic Pass Fail testing Max record length in Scope mode 3000 points per input channel allowing for high time resolution signal analysis using zoom 512 min max points per input in ScopeRecord mode 27 500 points per input or more 5 ms div 2 min div Number of inputs 2 plus external DMM input all isolated from each other and from ground 2 Number of digitizers 2 2 Independently floating Up to 1000 V between inputs refere
20. ts per second maximum Horizontal scale Time from start GENERAL SPECIFICATIONS CASE Design Rugged shock proof with integrated protective holster Drip and dust proof IP51 according to IEC529 Shock and Vibration Shock 30g Vibration 3g according to MIL T 28800E Type III Class 3 Style B DISPLAY Bright LCD with CCFL backlight 35 60 cd m without with adapter Size 72 x T2mm 2 8 x 2 8 inch Resolution 240 x 240 pixels Contrast and brightness User adjustable temperature compensated MEMORY SAVE AND RECALL REAL TIME CLOCK POWER Line power Battery power Battery operating time Battery charging time Battery power saving functions MECHANICAL DATA Size Weight SAFETY Compliance 20 Fluke 124 and 10 Fluke 123 instrument screens with user set ups and user text Time and date stamp TrendPlot recording Country specific line voltage adapter battery charger included Rechargeable Ni MH BP 130 installed in Fluke 124 or rechargeable NiCd BP 120 installed in Fluke 123 Up to 7 hours using BP 130 up to 5 hours using BP120 5 hours Fluke 123 7 hours Fluke 124 Auto power down with adjustable power down time On screen battery power indicator 50 x 115 x 232 mm 2 x 4 5 x 9 1 inches 1 2 kg 2 5 lb EN61010 1 2nd edition Pollution Degree 2 UL3111 1 CAN CSA C22 2 No 1010 1 ANSI ISA 82 01 Technical Datasheet Fluke ScopeMeters 6 INPUT VOLTAGE RATINGS Maximum input voltage 600V CAT
21. tycycle pos neg temperature C tempera ture F dBV dBm into 50Q and 600Q Vpwm ac VPwm act dc for measurement on pulsewidth modulated motordrives and frequency inverters CURSOR MEASUREMENTS Source Dual horizontal lines Dual vertical lines Single vertical line ZOOM Input A input B or the Mathematical Result trace excl A vs B curve Voltage at cursor 1 and 2 voltage between cur sors Time between cursors 1 T between cursors in Hz voltage between markers risetime with markers falltime with markers Vrms between cursors 190C only Watts between cursors 190C only Min Max and Average voltage at cursor position Frequency and RMS value of individual fre quency component in FFT Result 190C only Up to 16x horizontal zoom METER MODE Via 4 mm banana inputs Fully isolated from scope inputs and scope ground The specified accuracy is valid over the temperature range 18 C to 28 C 65 F to 82 F Add 10 of specified accuracy for each degree C below 18 C or above 28 C MAXIMUM RESOLUTION 5 000 counts VOLTMETER RANGES 500mV 5V SOV 500V 1 000V ACCURACY Vdc 0 5 5 counts Vac true ms 15 Hz 60 Hz 1 10 counts 60 Hz 1 kHz 2 5 15 counts Vac dc true rms dc 60 Hz 1 10 counts 60 Hz 1 kHz 2 5 15 counts OHMS Ranges 5009 5kQ 50kQ 500kQ 5MQ 30MQ Accuracy 0 6 5 counts OTHER METER FUNCTIONS Continuity Beeper on lt 50Q 30Q Diod
Download Pdf Manuals
Related Search
Datasheet datasheet datasheets 360 datasheet pdf datasheet archive datasheet catalog datasheet esp32 datasheet or data sheet datasheet lm35 datasheet gps module datasheet raspberry pi pico datasheet led datasheet ne555 datasheet dht11 datasheet meaning datasheet 7404 datasheet arduino uno datasheet 2n3904 datasheets for datasets datasheet atmega328p datasheet view access datasheet pic16f877a datasheet hc sr04 datasheet 1n4001 datasheet download datasheet rt6917 circuit diagram