Soladin Web DC Switch
Contents
1. THE POWER TO BE INDEPENDENT EN Soladin Web DC Switch 5 2 SAFETY GUIDELINES AND WARNINGS 2 1 WARNINGS AND SYMBOLS Safety instructions and warnings are marked in this manual by the following pictograms A procedure circumstance etc which deserves extra attention CAUTION Special information commands and prohibitions in order to prevent damage WARNING A WARNING refers to possible injury to the user or installer or significant material damage to the Soladin Web DC Switch if the installer user does not carefully follow the stated procedures 2 2 USE FOR INTENDED PURPOSE Use the Soladin Web DC Switch only in installations that meet these qualifications e in permanent installations e the electrical installation must meet the applicable regula tions and standards must be carried out correctly and must be in a good condition e according to the technical specifications WARNING Never use the Soladin Web DC Switch in situ ations where there is danger of gas or dust explosion or potentially flammable products Use of the Soladin Web DC Switch other than as mentioned under 2 2 is not considered to be consistent with the intended purpose Mas tervolt does not hold itself liable for any damage resulting from the above 2 3 ORGANISATIONAL MEASURES The installer user must always have access to this manual be familiar with the contents of this manual This applies particularly to Chapter 2 Safe
2. installation Use suitable testing equipment Read chapters 2 and 4 prior to installation Short circuiting miswiring or reverse polaritv mav lead to damage to the Soladin Web DC Switch the inverter the cabling and or the connections 3 1 THINGS VOU NEED FOR INSTALLATION Make sure vou have all the parts vou need to install the Sola din Web DC Switch e This printed user s manual included e 2 screws to fix the enclosure to the wall e Screwdriver to fix the Soladin Web Switch to the wall e Tools to install the optional grounding wiring 3 2 INSTALLATION STEP BV STEP 1 Fix the Soladin Web DC Switch to the wall the input facing downwards The screw holes are positioned at the center 110 mm apart Use suitable screws and plugs 2 Mount the optional resistance f 4 Connect wiring from the inverter check the polarity 5 Connect the wiring from the PV strings 6 Check string voltages and polarities Close the lid securely to prevent moist leaking inside Turn the screws clockwise to tighten the lid IS Fix the top screw first hang the Soladin Web Switch into position Then fix the bottom screw 3 3 COMMISSIONING AFTER INSTALLATION Move the DC switch to the ON position vertical 3 4 DE COMMISSIONING A If it is necessary to take the Soladin Web DC Switch out of operation follow these steps 1 Turn the switch to the 0 Off position 2 Disconnect the PV connectors first 3 Disconnect the Sol
3. H 1 7 IDENTIFICATION LABEL 1 8 TRANSPORT LIFTING AND STORAGE 1 9 INSTALLATION ENVIRONMENT 1 10 DC CONFIGURATION 2 SAFETY GUIDELINES AND WARNINGS 2 2 USE FOR INTENDED PURPOSE 2 4 INSTALLATION MAINTENANCE AND REPAIR 2 5 WARNING OF SPECIAL DANGERS 3 INSTALLATION AND COMMISSIONING 3 1 THINGS YOU NEED FOR INSTALLATION 3 2 INSTALLATION STEP BY STEP 3 3 COMMISSIONING AFTER INSTALLATION 3 4 DE COMMISSIONING 3 5 MAINTENANCE 3 6 PV GROUNDING 4 TECHNICAL DATA 4 1 TECHNICAL SPECIFICATIONS 5 EC DECLARATION OF CONFORMITY Actuant M VOLT COMPANV THE POWER TO BE INDEPENDENT 1 GENERAL INFORMATION 1 1 PRODUCT DESCRIPTION The Soladin Web DC Switch disconnects both the positive and negative cable going from the PV string to the Soladin Web It is suitable for the Soladin 700 Web 1000 Web and 1500 Web 1 2 USE OF THIS MANUAL Copyright 2013 Mastervolt All rights reserved Reproduction transfer distribution or storage of part or all of the contents in this document in any form without the prior written permission of Mastervolt is prohibited This manual serves as a guideline for the safe and effective installation of the Soladin Web DC Switch e For the electrician this manual provides directions for the installation operation and commissioning e For the end user it instructs in operation and maintenance e Every person who wor
4. S directive The following harmonized standards have been applied iec 60947 1 iec 60947 3 Amsterdam Ing D R Bassie Product Manager Solar July 4th 3013 MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands T 31 0 20 342 21 00 F 31 0 20 697 10 06 www mastervolt com MPSTERVOLT THE POWER TO BE INDEPENDENT
5. Soladin Web DC Switch UK USERS AND INSTALLATION MANUAL P01 NL GEBRUIKERS EN INSTALLATIEHANDLEIDING P9 DE BEDIENUNGS UND INSTALLATIONSANLEITUNG P17 FR MANUEL UTILISATEURS ET D INSTALLATION P25 ES MANUAL DEL USUARIO Y DE INSTALACION P33 IT MANUALE DI USO E MANUTENZIONE P41 10000006477 01 Actuant M VOLT COMPANV THE POWER TO BE INDEPENDENT 2 EN Soladin Web DC Switch OVERVIEW SOLADIN WEB DC SWITCH 1 Output plus to Soladin 2 Input plus from PV string 3 Output minus to Soladin 4 Input minus from PV string G PE terminal positive input 2x N PE terminal minus input 2x S Switch knob 0 Switch Off position Switch On position 4 MASTERVOLT on ON N BG B G B MASTERVOLT S Va Figure 0 1 Overview of the Soladin Web DC Switch Soladin Web DC Switch 3 CONTENT 10000006477 00 July 2013 1 GENERAL INFORMATION 1 1 PRODUCT DESCRIPTION 1 2 USE OF THIS MANUAL 1 3 VALIDITY OF THIS MANUAL 1 5 LIABILITY 1 6 CHANGES TO THE SOLADIN WEB DC SWITC
6. adin connectors 4 Disconnect the optional grounding Now the DC Switch can be taken off the wall safelv 3 5 MAINTENANCE If necessarv use a soft clean cloth to clean the enclosure of the Soladin Web DC Switch Never use liquids acids and or scourers Examine vour electrical installation on a regular base at least once a vear Defects such as loose connections burnt wiring etc must be corrected immedi atelv PE Figure 3 1 Grounding by means of a resistor 3 6 PV GROUNDING Depending on the PV panel type functional grounding is required The Soladin Web DC Switch includes material to ground either the inverter input plus or minus See figure 3 1 Use the 100 k Ohm resistor R to connect 2 or 4 to PE Follow these steps using figure 3 1 1 Make sure no DC is present refer to chapter 2 2 Connect the PE terminal to your PE connection 3 Connect the 100 k Ohm resistor with the PE terminal 4 Connect the other side of the resistor to 2 positive input or 4 minus input Soladin Web DC Switch T 4 TECHNICAL DATA 4 1 TECHNICAL SPECIFICATIONS GENERAL SPECIFICATIONS Model Soladin Web DC Switch Part number 130500640 Operating temp 20 C 45 4 F 113 F Protection degree IP 66 Relative humidity 4 90 condensing Safety class Class 11 Weight 450 g including cables Dimensions See figure 4 1 SOLAR IN OUTPUT DC Maximum
7. ification label is positioned at the right side of the Soladin Web DC Switch CAUTION Never remove the identification label 1 8 TRANSPORT LIFTING AND STORAGE Ensure adequate and secure packaging during transporta tion of the DC Switch Always use suitable handling equip ment for transportation 1 9 INSTALLATION ENVIRONMENT Obey the following stipulations during installation e The Soladin Web DC Switch is designed for both indoor and outdoor use according to protection class IP66 e Ambient temperature 20 to 40 C 1 10 DC CONFIGURATION The solar or DC side of the system consists of several pho tovoltaic solar modules connected as PV string These strings consist of a plus and a minus connection which can be connected to the Soladin inverter via the Sola din Web DC Switch The cabling between the DC Switch and the inverter must be double insulated and suitable for 400 V DC and 15A DC 1 11 PV INSTALLATION REQUIREMENTS The PV installation has to meet next specifications e The maximum open circuit string voltage at lowest possible temperature of the string may not exceed 400V e Double isolated PV wiring fitted with Amphenol Helios H4 connectors at the inverter side must be used e The maximum power connected to the switch may not exceed 400Vdc 15Adc for each output Do not install the Soladin DC Switch if the solar svstem does not complv with the stipulations mentioned above M STERVOLT
8. input output voltage 400 V DC Maximum input 7 output current 15A String connections 1 string with DC switch in positive and minus cable 4 2 ORDERING INFORMATION Part number Description 130500640 Soladin Web DC Switch DC switch to be connected between PV arrav and Soladin Web 130000700 Soladin 700 Web 130001000 Soladin 1000 Web 130001500 Soladin 1500 Web Mastervolt offers a wide range of products for both grid connected and independent autonomous electrical installations See our website www mastervolt com for an extensive overview of all our products 4 3 OUTLINE DRAWINGS 1 100 122 110 MASTERVOLT 14 gt Figure 4 1 Drilling dimensions of the Soladin Web DC Switch in mm M STERVOLT THE POWER TO BE INDEPENDENT 8 EN Soladin Web DC Switch 5 EC DECLARATION OF CONFORMITY We Manufacturer Mastervolt Address Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Declare under our sole responsibility that the product Article number Product name 130500640 Soladin Web DC Switch is in conformity with the provisions of the following EC directives 2006 95 ec LV directive 2004 108 ec EMC directive 2011 65 eu ROH
9. ks with the apparatus should be familiar with the contents of this manual and must carefully follow the instructions contained herein e Store the manual in a user accessible place 1 3 VALIDITY OF THIS MANUAL All the specifications provisions and instructions contained in this manual apply solely to the Mastervolt delivered standard version of the Soladin Web DC Switch 1 4 GUARANTEE SPECIFICATIONS Mastervolt assures the product guarantee of this DC Switch during five years after your purchase on the condition that all instructions and warnings given in this manual are taken into account during installation and operation Installation must be carried out by a qualified electrician The warranty is limited to the costs of repair and or replacement of the product by Mastervolt only Costs for installation labour shipping of the defective parts and loss of energy revenues are not covered by this warranty For making an appeal on warranty you can contact your supplier directly stating your complaint application date of purchase and part number serial number 1 5 LIABILITY Mastervolt accepts no liability for e consequential damage of using the Soladin Web DC Switch e possible errors in the manuals and their results 4 EN Soladin Web DC Switch 1 6 CHANGES TO THE SOLADIN WEB DC SWITCH Changes to the Soladin Web DC Switch may be carried out only after the written permission of Mastervolt 1 7 IDENTIFICATION LABEL The ident
10. ty Guidelines amp Warning 2 4 INSTALLATION MAINTENANCE AND REPAIR WARNING As high voltages exist only allow installation maintenance and repair of the Soladin Web DC Switch and changes in your electrical system to be carried out by qualified electricians Con nections and safety features must be executed according to the locally applicable regulations If such are required only use original spare parts Use the special Amphenol tool when taking the Amphenol connectors apart Actuant COMPANV 2 5 WARNING OF SPECIAL DANGERS The voltages present at both sides of the Soladin Web DC Switch and inside the enclosure are not safe to touch Do not work on the Soladin Web DC Switch and or the electrical installation if it is still connected to the PV panels or the inverter Allow time for the inverter capacitors to de energize Verifv de energizing of all connections using a suitable metering instrument Make sure two persons are present when working on an installation at least until the installation has been de energized and verified bv a suitable metering instrument M STERVOLT THE POWER TO BE INDEPENDENT 6 EN Soladin Web DC Switch 3 INSTALLATION AND COMMISSIONING CAUTION Until all wiring has been verified to be de energized for safetv reasons at least two persons are required during installation Verifv that all wiring is disconnected from anv energy source during the entire
Download Pdf Manuals
Related Search
Related Contents
manuel gestion concours 2010_3_1 consultation - KBL Richelieu EG1150 C_2v1_it Istruzioni per l`uso CENTRALINE 96/U-98/U-01/U the Conservation Rooflight® Pleated Blind Installation Manual CamPart Travel CU-0721 品番 DMP-BD60 Plano Nacional de Prevenção Rodoviária Contrôle de la pédiculose (poux et lentes) カシオ サステナビリティレポート 2015 Copyright © All rights reserved.