Home

Installation Guide

image

Contents

1. 181 DEI configured systems will operate without a LAN ETHERNET connection fe 1 1 1 1 1 1 Figure 7 5 LAN LEDs www linearcorp com 19 e3 eMerge Installation Instructions Note The Server and Client require independent network connections www linearcorp com 7 3 Adding a Client Some e3 eMerge systems provide the ability to add additional controllers to expand the amount of doors or elevator control inputs and outputs These additional controllers are referred to as clients A client can be mounted on top of the main controller server for systems using metal enclosures or in a separate enclosure Mounting a Client to a Server 1 Disconnect power from the controller 2 Remove the 4 screws securing the shield over the controller 3 Position the expansion board over the 4 existing standoffs and fasten using the standoffs included with the new controller Do not over tighten or the expansion controller could be damaged 4 Install the shield over the expansion board using the 4 screws removed in Step 2 5 Connect the client and server to the network and apply power The client s power connection must be connected to the output of the power supervision module or you can use the approved PoE module See section 4 in this manual for power connections co Standoffs gt i Included with Expansion C
2. 4 The power LEDs DL17 and DL9 on the panel will turn on to indicate power is present Figure 4 1 Power Connection 8 e3 eMerge Installation Instructions Power Fault Connection The controller is equipped with a power fault input that can be utilized as follows Note The system settings must match the 1 Determine whether your power fault input device uses a normally closed or normally open requirement normally configuration Please refer to instructions provided by the manufacturer 2 Connect the power fault input device to PIN 3 and PIN 4 on the terminal strip detection device 3 Verify that the power fault input device is functioning properly Power Fault Input Figure 4 2 Power Fault Connection Tamper Protection A tamper switch is mounted inside the enclosure and is pre wired to the tamper input on the terminal strip If the cover is removed for any reason the tamper switch will activate triggering a condition that can be linked to an event action in programming e g send an e mail or generate an output www linearcorp com 9 e3 eMerge Installation Instructions Caution A 12VDC power supply MUST be used Incorrect voltage will damage the product and void the warranty Minimum Cable Specifications for power 16 AWG Belden 2 conductor or equivalent Maximum distance 6 feet 1 8 meters Note Wiring methods shall be in accordance with the National Electrical Code NPFA 70 and all local
3. IP Address Subnet Mask Gateway DNS Server 1 Optional DNS Server 2 Optional HTTP Port Default 80 Server 192 188 20 202 Default 20000 EE Enter password and click Save Enter e3 Server IP address Password 5 Enter the IP address of the server as entered in IP Installer 6 Enter the password default admin and click Save Link the Client to Server 1 Using a web browser on a local computer enter the IP address of the server as listed in IP Installer 2 The browser presents the Linear page as shown 22828202 220020 8 029 client placement site Management Building Un Innovation Click Client Management 88888888 04 30 2013 20 57 46 4 After logging in click Client Management www linearcorp com 23 e3 eMerge Installation Instructions C linear emerge Opera la opera unear emerge x Configuration gt Client Management 11711 168 Building On Innovation 1 Client Door4 192 168 20 155 FO D1 4F 00 00 0B On 032021 Threat Level Status 5 The client will appear in the list Click the Use Not Use button to link the client to the server The button will display Use when the client is successfully linked to the server Linear eMerge Opera opera emerge O web 75 147 92 201 9080 29
4. codes Note The system will not power up using the backup battery The 12VDC power must be present to power up the system Note Replace the backup battery every 2 to 3 years Note Parallel connected batteries will take approximately twice as long to charge as a single battery www linearcorp com 4 2 Power Connection for Systems using the Metal Enclosure Systems using metal enclosures include a factory installed power supervision module as shown in Figure 4 3 Power Supply Connection 1 Connect 12VDC from the included power supply to the RED and BLACK leads on the panel Note e3 eMerge systems require a 12V DC 2 amp Class 2 power supply Incorrect voltage will damage the product and void the warranty 2 Connect an earth ground to the green earth ground lead provided in the enclosure 3 Turnon the power supply If using a PIP for the power supply it must be plugged into a dedicated receptacle that is not controlled by a switch 4 The power LEDs DL17 and DL9 on the panel will turn on to indicate power is present 5 Connect the leads to the battery see below DUAL BATTERY INSTALLATION Connect Batteries in Parallel 41 BATTERY 82 lt gt e m FLT Qs FLT 2 To Power Supervisor amp EG Battery Charger Module BLACK Use minimum of 12GA stranded wire Use insulated terminals on battery terminals Figure 4 3 Power Conn
5. controller that will use the PoE option Note Linear module P N 620 100159 requires additional high power injector Linear 30W POE injector POE PLUS Note For PoE applications only use UL294B listed PoE power supplies PoE is not supported for installations requiring UL294 www linearcorp com To determine standby battery time 1 Determine the total standby load of the system by adding the maximum and standby current draw of the devices connected to the panel For example if the system consists of the control panel 200 mA and one 75 mA reader the total standby load is 275 mA 200 mA 75 mA Divide the total standby load by 1000 to convert it to amps For example 275 1000 275 3 Divide the amp hour rating of the battery by the total standby load to determine the standby time for the system For example 7 0 275 25 5 hours standby time using a 7 AH battery with a system that consists of the control panel and one 75 mA reader Power Fault If AC power loss is detected the power supervision module will automatically switch to the backup battery and activate the fault input The fault input can be configured via programming to trigger an event such as e mail or popup message The transaction will be logged in the history of the controller Tamper Protection A tamper switch is mounted inside the enclosure and is pre wired to the tamper input on the terminal strip If the cover is removed for any reas
6. e3 eMerge Installation Instructions 1 0 Introduction This manual contains information regarding the basic installation wiring and configuration of the e3 eMerge browser based access control systems Systems are available in a space efficient and durable plastic housing or in a heavy duty steel cabinet featuring a self contained battery back up with a supervised power supply All systems use the same control panel layout and system wiring 1 1 Access Control Overview Access control systems are designed to monitor and control access throughout a building or restricted area An access control system involves the use of an access device card PIN code etc which is presented at an entry device reader keypad to gain access When access is granted a door is unlocked for a pre programmed amount of time and a transaction is recorded in a database for reporting or tracking purposes 1 2 System Overview Systems are available in a variety of models starting with one door two reader configurations Models can be upgraded with expanded capabilities using optional software license keys The e3 eMerge includes Ethernet support an integrated web server and Power over Ethernet PoE support Specifications Cortex 1GHz On board RAM 512MB DDR2 333MHz Sed endore WxHxD Temperature specification 4 F to 120 F 20 C to 50 C Regulated 12VDC 2A www linearcorp com 2 e3 eMerge Installation Instructions 1 3 Installation Overv
7. 1714 L INVA 2 21 1Q 1 1 T Qva1qTiaiHs 8 HLYVI O EN slid m e G3 INVI 1015 QS 7 monn u O a O oooooo T WM INPUT GND INPUT 19 2 2 REX GND DOOR CONTACT YICVIY LNO 3O0V38 NI 1 AUX IN 1 GND 1 AUX IN GND AUX INPUT 4 AUX INPUT a 50000010100 3 B 610 ora on o Q ON Ope LS 969 eJewpJeH zs onl r N Dal Qu 2 ON 2 ON 1 INPUT Ya dvs NI LS 1 6 100 GND 80 2 REX DOOR CONTACT il Qu on 1 2121 QW IB 210 Di BE o Q l j x on 210 7 M901L 4000 ti 1 I NI N 4 8 E 8 M LAV T3H XV s 2 amp x x l eavtauxny M M e t AVY XNV 2 x 8 8 a gt 2 eMerge Installation Instructions 27 www linearcorp com 10 Notes www li
8. 3 DL11 AUXRELAY2 4 DL10 D 21012 E 20011 B 00000 AUXRELAY 1 ie me Dl tamper 52 Hardware reset l A 1 Factory default 1 PWR FAULT PU DOOR 2LOCK _ lt 2 _ Di 12VDC Micro SD TO omm DOOR1LOCK _ lt 2 B Note Wiring methods shall be in accordance with the National Electrical Code NPFA 70 and all local codes Note The terminals are designed to accept 12 22 AWG solid or stranded wire Note To factory default the system press amp hold S1 for 20 seconds When released the system will start the factory default process Itis VERY important to wait 2 3 minutes for a solid blue LED DL1 before programming the system All user data will be erased including the license key www linearcorp com 5 TE 62 Eoz VOO 899599558 S IS GS SSSSSSSS JP1 Power Input 5 x2 MI 1148 External TIE HERB e 3 x INREADER OUTREADER INREADER OUT READER Figure 2 1 Board Layout Table 2 1 LED Indicators Table 2 2 Default 1 0 States LED Condition Attribute Default State DL17 Red On Power On Middle Board Door Status Inputs Normally Open Unsupervised 8 Sec Held Open Time Q 09 Red On Power On Bottom Board REX
9. 39 20200 Door Elevator AUXInput C AUXOutput Controller a Rn Building On Innovation Client 1 Client Door 4 Default Floor Client 1 Client Door3 Default Floor Normal Client 1 Client Door 2 Default Floor Normal Client 1 Client Door 1 Default Floor Normal Server Server Door Default Floor Normal E3 Time Server Server Door Default Floor Normal 04 30 2013 21 14 45 Server Server Door Default Floor Normal Server Server Door Default Floor Normal 6 Click the Door icon and verify that the client doors are listed The client and server are now linked together 7 5 Programming the System The system provides the ability to access and manage the system from a web browser on any local or remote computer The system can be programmed using a simple Wizard tool or the user to configure the basic settings Visit the Wizard at any time by clicking icon in the lower left corner of the web page Refer to the User Programming Guide P N 620 100240 for specific programming and configuration instructions www linearcorp com 24 e3 eMerge Installation Instructions 8 0 Troubleshooting Note Systems are shipped with a USB stick drive that contains complete documentation tutorials and other information After installing the USB Stick drive navigate to the drive and click on clickme and your browser will open the web page with additional information www linearcorp com Table 8 1 Troubleshooti
10. Inputs Normally Open Momentary Unsupervised DUI Blue On System is Rebooted Auxiliary Inputs Normally Open Unsupervised 011 to DL16 Blue On System is Booting Door Lock Outputs Not Energized Single Pulse 3 Second Unlock Time Aux Outputs Not Energized Single Pulse 3 Seconds On DL19 DL18 Blue Blink Network Connection NOTE System start up time is approx 60 secs Note For UL installations the maximum Ethernet cable length is 30m 98 5 FT e3 eMerge Installation Instructions 3 0 Installing the Control Panel Note This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note Choose a centrally located secure clean and dry area near an AC power source Avoid mounting the panel within 6 feet of any equipment that generates electrical interference Caution This equipment includes electronic components that are highly sensitive to static electricity Please discharge by touching an earth ground before installing or handling this equipment Note The compact enclosure will not accommodate a backup battery If using a backup battery a separate housing must be installed or use PoE supply with suitable UPS backup Note The plastic housing is not listed for instal
11. SERIES Linear e3 eMerge Access Control System Document Number 620 100531 Rev B Installation Instructions BF NORTEK SECURITY amp CONTROL USA amp Canada 800 421 1587 amp 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www nortekcontrol com Notices All rights strictly reserved No part of this document may be reproduced copied adapted or transmitted in any form or by any means without written permission from Nortek Security amp Control LLC Standards Approvals This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense e3 eMerge systems are Level UL 294 listed devices and must be installed in controlled locations Corporate Office Nortek Security amp Control LLC 1950 Camino Vida Roble Suite 150 Carlsbad CA 92008 6517 Tel 800 421 1587 760 438 7000 Fax 800 468 1340 760 931 1340 Tech
12. UL installations a Linear Plug in Power supply PIP is required see below The system may also be powered by a high Power over Ethernet PoE injector using an optional Linear PoE module 9 Linear 12VDC 24W 2A PIP P N 0 291312RU 9 Linear 12VDC 60W 5A PIP P N 0 299177RU required for UL installations Linear PoE module P N 620 100159 requires additional high power PoE injector PoE is not supported for installations requiring UL294 4 1 Power Connection for Systems using Compact Enclosure Power Supply Connection 1 Connect 12VDC from the included power supply to the 12V and GND input terminals on the panel Note e3 eMerge systems require a 12VDC 2 amp Class 2 power supply Incorrect voltage will damage the product and void the warranty 2 Connect an earth ground to the green earth ground lead provided in the enclosure 3 Turn on the power supply If using a PIP for the power supply it must be plugged into a dedicated receptacle that is not controlled by a switch Note A green wire pigtail for EARTH s GROUND amp earth ground is provided in all READER enclosures SHIELD LEAD Connection for Linear PIP 12VDC 24W PIP 12VDC 60W PIP Use 60W PIP for the UL installations Earth GND 12 VDC Note A separate power supply MUST be used for door locks and accessories A power supply shared between the system and door locks and accessories may cause damage or intermittent operation
13. act Enclosure 8 4 2 Power Connection for Systems using Metal 10 4 3 PoE Connection 11 SDdnputs and OUTPUTS recresen 12 551 5 5 8001 Aa alto e ob dude debe iei oe etna 12 5 2 Wiring the Inputs sx sea ERN Nettuno c TIA 13 5 3 System rrr b RR OUO DE FERE E RERPPREIREREI ITI 300388855 14 5 4 Door Eock Outputs ienee aaa EROR ORO Ite d a EDU ERR RR EE Rd d 15 GO BEASTS uan RAR RADO IR 16 6 Wiring the Readers Rai Ra 16 7D Network CONNECTION 17 7 1 Preparing for the Network i 17 7 2 Connecting to the Network ERR VER EE ERR REPRE EE Ep 18 7 3 accuses citer te ette ritenere rmt alter Ro RR RR RUE 4454 58 20 7 4 Configuring the Client and Server on the 21 7 5 Programming the Systemu irrita 24 221 616 PR TT 25 9 0 Test Maintenance and Service 26 9 1 Testihig REA EEE 26 9 2 no KE RI ERRE IRIS 26 93 SEIVICO M 26 LSU e M ARA iii RR IRPI 26 10110168 curren 28 1
14. e of the system and restore Note If factory defaulted all configuration information will be lost including the license key To factory defaults retrieve the license key visit www e3upgrade com and enter the MAC address of the controller MAC Address is printed on the product For further troubleshooting assistance please visit the following online resources 9 http www nortekcontrol com faq http Avww learnlinear com 9 http www e3links com Nortek Security amp Control Technical Support Tel 800 421 1587 9 Hours 5 00 AM to 4 30 PM Pacific Time M F 25 e3 eMerge Installation Instructions 9 0 Test Maintenance and Service 9 1 Testing Monthly testing of the system is recommended Check that all used inputs and outputs are correctly functioning with the connected devices Check that system and log backups are occurring at scheduled times 9 Check for proper operation of backup battery a precaution backup system data before performing a battery test 9 2 Maintenance The systems require very little maintenance It is recommended to check the following every 6 months Cover or door is secure 9 Enclosure is clean and dry 9 All wires are securely connected to the terminals and proper strain relief is used 9 3 Service These systems contain Class 2 circuits Do NOT alter or tamper with any of the components in these systems There are no user serviceable parts on the controllers
15. e slots 3 Remove the metal cabinet knock outs required for wire entry and install bushing or conduit connectors as needed to protect wires from damage 4 Level the enclosure on a sturdy wall Mark the mounting holes with a pencil The cabinet can be vertically or horizontally mounted depending on space requirements 5 Partially insert screws into the top two mounting holes and hang the enclosure on the screws 6 Pull all wires through the knock out holes in the enclosure Label each wire according to its use 7 Recheck for level insert the two lower screws and tighten all four mounting screws 8 Re install the door and connect the ground wire to the door EARTH GROUND amp READER SHIELD LEAD ssssss Figure 3 3 Metal Enclosure 7 e3 eMerge Installation Instructions 4 0 System Power Note For PoE applications only use UL294B listed PoE power supplies Caution A 12VDC power supply MUST be used Incorrect voltage will damage the product and void the warranty Note Power should only be applied to the system when all connections are secured and tested MINIMUM Cable Specifications for power Use a minimum of 16 AWG Belden 2 conductor or equivalent Maximum distance 6 feet 1 8 meters Note Wiring methods shall be in accordance with the National Electrical Code NPFA 70 and all local codes www linearcorp com The system panel requires a 12VDC 2A supply not included For
16. ection for Systems using Metal Enclosure Battery Connection The metal enclosure provides charging and space for up to two 12VDC 7Ah sealed lead acid batteries not included The battery provides standby power when the primary power source is lost The control panel will utilize backup battery until the battery voltage reaches 11VDC at which point the entire system shuts down Connecting Batteries in Parallel Connecting batteries in parallel will double the capacity amp hours of the backup while maintaining the proper voltage Parallel connected battery connection is shown in Figure 4 3 Warnings Use caution when installing batteries Incorrect use can damage the battery controller or can cause a fire 9 Connect a maximum of two identical batteries in parallel DO NOT connect batteries in series This will damage your system and void the warranty 9 The battery backup and charging uses advanced circuitry Maximum charge rate is 650mA Once the battery is fully charged it is maintained with an occasional 10mA charge Ensure these ratings do not exceed the manufacturer s rating for the battery 9 Properly dispose of old batteries 10 e3 eMerge Installation Instructions Note Each controller consumes 200 mA of current at 12VDC 2 4W Note When a power fault is detected and the battery backup is used system may be configured to back up database and log files to the microSD card Note A PoE module is required for each
17. ether the door is in an open or closed state A door status switch typically a magnetic reed switch will change states when the door is opened or closed The door status input does not require any programming to enable however you will have to select either normally open NO factory default or normally closed NC operation in the panel Simply connect a magnetic reed switch to the appropriate door input as shown in the control panel illustration Figure 2 1 Request To Exit The Request to Exit REX input is a momentary input closure that activates the door output relay for the same amount of time as a valid card swipe or keypad entry REX devices can include a press to exit switch on the inside of a door or a passive infrared detector motion detector which allows convenient egress Ihe REX input does not require any programming Simply connect a normally open NO factory default momentary input device to the REX inputs shown in the control panel illustration Figure 2 1 Auxiliary Inputs The auxiliary inputs are general purpose inputs that can be used with a variety of input devices including CO2 detectors alarm system integration etc These inputs can be configured via programming to trigger a defined action such as to activate an auxiliary output 12 e3 eMerge Installation Instructions Minimum Cable Specifications 22 AWG Belden or equivalent Maximum distance 2000 feet Note Wiring methods shall be in accordance wi
18. he client and server must be changed as follows 1 Connect the server to the network 2 Open IPInstaller exe and click Scan 3 Select the server from the list and click Set Network 4 Enter a new IP address for the server This information must be provided by the IT Administrator 5 Change the Subnet Mask and Gateway to meet the requirements of the local network 6 Enter the IP Installer password default 4321 and click OK 7 Connect the client to the network and repeat steps 1 through 4 to change the client s IP address 21 e3 eMerge Installation Instructions www linearcorp com Assign the Server to Client After the controllers are located on the network the client must be linked to the server as follows 1 Using web browser on a local computer enter the IP address of the client as configured in IP Installer 2 The browser presents the Linear page as shown W Opera Linear eMerge oP EE 192 168 20 155 3 log on enter the user name default admin and password default admin 4 After a successful log on the browser presents the page as shown Click Edit Client IP Type DHCP IP Address 192 188 21 182 Subnet Mask 255 255 255 0 Gateway 192 188 21 255 DNS Server 1 DNS Server 2 HTTP Port Server IP 192 168 0 250 Click Edit Port 20000 admin 22 e3 eMerge Installation Instructions Client IP Type 6 DHCP C Static
19. iew Checklist Note The checklist The following list presents the steps required for successfully installing a system provides a logical sequence for installing a FJ Mount the enclosure system Connect the readers Wire the inputs and outputs Connect power to the system Obtain IP address and other TCP IP information from network administrator Configure the network settings for the system Connect the system to a local area network LAN UO Q Optional Add licenses for additional doors and readers www linearcorp com 3 e3 eMerge Installation Instructions 2 0 Control Panel Layout 2 1 Control Panel Components The following illustration shows the e3 control panel wiring and components OUTREADER INREADER INREADER OUT READER gt c T z z gt S898 03 8868 49 52 EE o 02 SSS 4 E 222 2 2 di EARTH GROUND amp READER SHIELD LEAD DOOR 3 LOCK L oo0000 unie 0 DOOR 4 LOCK e H ETHERNET n n O AUX RELAY 4 LEDBANK 5 DURER DLS E 8017 DL14 E E DLE DL13 015 DL12 E
20. it matches the requirements of the local network Refer to the User Manual for complete programming information ug De MCA C pe DX 5 gt IPAddress H Update Server Time Server Linear Building On Innovation IP Type DHCP Static E Optional Optional E Default 8 IP Address Subnet Mask Gateway DNS Server 1 DNS Server 2 HTTP Port Figure 7 3 Network Settings Page 6 Click Save amp Reboot and the system will reboot Reboot will take approximately 2 minutes Note The system data will be lost if the controller is powered down without performing Save amp Reboot 7 Disconnect the programming computer from the control panel The system is now ready for the local network 7 2 Connecting to the Network 1 Pullan Ethernet cable through the opening in the enclosure nearest the Ethernet port 2 Plug the RJ 45 connector into the Ethernet port on the controller 3 Connect to the local area network LAN as shown in Figure 7 4 eMerge e3 Router Client Computer Figure 7 4 Connecting to a LAN If the network connection is functioning properly the LAN LEDs on the control panel will illuminate as shown in Figure 7 5 The local computers will then be able to access the system by entering the IP address of the controller 18 e3 eMerge Installation Instructions Note LAN connection is only required for monitoring reporting
21. lations that require UL 294 Note Tie down loops are located in the enclosure and used to provide strain relief for field connections www linearcorp com 3 1 Mounting the Compact Enclosure The housing is designed to accommodate the necessary wiring connections for most installations The compact enclosure is optimized to run wires under the back panel and thru the knockouts shown in Figure 3 1 and Figure 3 2 The enclosure should be mounted vertically on a wall in a secure location within normal temperature and humidity levels Installing the Panel Run all necessary wires to the panel location oy Mug cos p x Figure 3 1 Compact Enclosure e Remove the enclosure s cover by removing the two screws in the front of the housing Level the enclosure on a sturdy wall Mark the mounting holes with a pencil Partially insert screws into the top two mounting holes and hang the enclosure on the screws Pull all wires through the knock out holes in the enclosure Label each wire according to its use Recheck for level insert the two lower screws and tighten all four mounting screws Mounting Hole Enclosure Knockouts C Cover Screw Enclosure Knockouts EARTH GROUND amp READER SHIELD LEAD Cover Screw Wire Tie Down Loops e3 eMerge Installation Instructions Moun
22. nearcorp com 28 e3 eMerge Installation Instructions Notes www linearcorp com 29 e3 eMerge Installation Instructions Copyright 2015 Nortek Security amp Control LLC 3 SERIES BF NORTEK SECURITY amp CONTROL USA amp Canada 800 421 1587 amp 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www nortekcontrol com 620 100531 B
23. ng the System Question Solution e Check setting of JP1 on middle board near input power connector to ensure that the jumper is in the appropriate position for your desired power source Measure input power for 12VDC If RED LED s are off then input fuse may be blown This fuse is not field replaceable The control panel does not power up The control panel powers up but does not respond to card readers or inputs Measure power at reader connectors If no voltage is present then reader fuse may be blown Bring reader and or input and connect directly at the panel If it works at the panel the wire run may be faulty No network communication exists with the control panel If LAN LED are off or solid then no physical network connection exists Check network cabling Verify the Subnet Mask Gateway DNS and IP address as provided by the network admin have an unlicensed controller how do obtain a license key The MAC address is printed on the controller Using the MAC address the license key can be obtained by visiting http www e3upgrade com and entering the MAC address How to reboot the system Hardware Reboot system Momentarily press switch S2 on middle board near bank of 16 LED s Press and Hold switch S1 for full 20 seconds on middle board near bank of 16 LED s How to clear the memory You may also reboot and factory default the system using the GUI softwar
24. nical Support Tel 800 421 1587 Hours 5 00 AM to 4 30 PM Pacific Time Monday Friday Notice It is important that this instruction manual be read and understood completely before installation or operation is attempted It is intended that the installation of this unit will be performed only by persons trained and qualified in the installation of access control equipment The important safeguards and instructions in this manual cannot cover all possible conditions and situations which may occur during installation and use It must be understood that common sense and caution must be exercised by the person s installing maintaining and operating the equipment This installation manual is for e3 eMerge systems Contents www linearcorp com asd eie 2 1 1 Access Control Overview 2 1 2 Systemi 2 RR a RR Rr e Me 2 1 3 Installation Overview Checklist esses 3 20 Control Panel 4 2 CcontroliPanel 5 ITER RT 4 3 0 Installing the Control Panel ccc ccc cece cence eee e cette tent ee 5 3 1 Mounting the Compact Enclosure esses en 2 3 2 Mounting the Metal 5 20222229553211122121134 3 22 41414444 44 7 SE qas 8 4 1 Power Connection for Systems using Comp
25. nnection crossover is not required You may also connect the computer and controller to an Ethernet Switch A standard Ethernet may be used for the direct connection crossover is not required nonni 00000010 suns ES SD 555556 aug 4 Figure 7 1 Connecting to the Control Panel 2 Assign a static IP address of 192 168 0 149 to the computer For instructions on how to change the static IP address of a Windows computer please visit http technet microsoft com en us library f710457 After assigning the static IP address open a web browser and enter the IP address of the controller Default 192 168 0 250 The controller presents the e3 page as shown in Figure 7 2 To log on enter the default user ID and password admin admin Figure 7 2 Login Page 17 e3 eMerge Installation Instructions Note The system data will be lost if the controller is powered down without performing Save amp Reboot Cable specification CAT 5 or better with an RJ 45 connector wired straight through to a network hub switch or router www linearcorp com 5 Browse to the Network Configuration IP address page as shown in Figure 7 3 Enter the static IP address Subnet Mask Gateway and DNS server so that
26. on the tamper switch will activate triggering a condition that can be linked to an event action in programming e g send an e mail or generate an output 4 3 PoE Connection optional Systems can be powered using Power over Ethernet PoE which is a method for providing power via Ethernet cabling To place the controller in PoE mode move the Power Input Jumper to the left position as illustrated in Figure 4 4 A Power over Ethernet installation must use a high power 30W PoE injector and the Linear E3 POE module Refer to the PoE module installation guide for specific installation information POE o o o Default EXTERNAL 12VDC e3 PoE Module Installed Figure 4 4 Power Input Jumper 11 e3 eMerge Installation Instructions 5 0 Inputs and Outputs www linearcorp com 5 1 System Inputs Systems have the capability of monitoring door status door contact inputs request to exit REX inputs and auxiliary general purpose inputs All inputs are assigned default features that can be configured as needed The following table shows the default states for each of the inputs Table 5 1 Default Input States Input Default State Door Status Inputs Normally Open Unsupervised 8 Second Held Open Time REX Inputs Normally Open Momentary Unsupervised Auxiliary Inputs Normally Open Unsupervised Door Status Input The door status input monitors wh
27. ontroller lt gt Expansion Board Client SS Adhesive Label N Pali Figure 7 6 Mounting Client to Server 20 e3 eMerge Installation Instructions Note You will have to change or modify the fire wall settings the first time IP installer is run Note Consult the appropriate on site IT Administrator when changing the IP Address Subnet Mask and Gateway www linearcorp com 7 4 Configuring the Client and Server on the Network IP Installer is a utility located on a thumb drive shipped with all systems The purpose of this utility is to locate the server and client on the network It also provides a simple method of changing the IP address of the controller s Run IP Installer 1 Connect all controllers to the local network N Connect the thumb drive included with the system to a Windows computer on the local network 3 Locate IP Installer exe and double click the file 4 IP Installer will open Click Scan to search the network for controllers 5 When controllers are identified they will be listed in IP Installer eMerge IP Installer lele mci MAC Address IP Address Device Model 1 FO D1 4F FF FF 0A 10 5 139 950 Static Enterprise 128 Scan 1 Item Set N Exit Figure 7 7 IP Installer Change the IP Address of Server and Client The default IP address of the server and client is 192 168 0 250 To avoid conflict on the network the IP address of t
28. oo CA ono Figure 6 1 KC Y X IN READER Reader Wiring typical Note A green wire pigtail for earth ground is provided in all enclosures Reader shields must be properly grounded per manufacturers installation requirements 16 OUT READER e3 eMerge Installation Instructions 7 0 Network Connection The controllers must be located in a trusted network environment where a protected network security system firewall etc is installed and maintained Obtain the following information from your network administrator before configuring the controller 9 IP address 9 Subnet Mask Caution The system is exposed to potential risks if installed on a network without proper security precautions Consult the appropriate on site IT administrator Note If a DHCP server is present IP Addresses are dynamically assigned A static address is strongly recommended for the controller because a DHCP Server may assign a new IP Address Note For UL installations the maximum Ethernet cable length is 30m 98 5 FT www linearcorp com 9 Gateway 9 DNS1and2 7 1 Preparing for the Network To allow for the system to be recognized on the local network it is necessary to change the controller s IP address as follows 1 Connect your programming computer directly to the Ethernet port of the controller as shown in Figure 7 1 A standard Ethernet may be used for the direct co
29. or on the power supervision and battery charger module Contact technical service for assistance if you are experiencing operational difficulties Batteries used for the power backup should be replaced every 2 3 years If using two batteries always replace both batteries with new identical batteries 9 4 Parts List Polycarbonate Shield 5 06 ere Rt tete ae P e Ar Airea 620 100070 Polycarbonate Shield for Elevator 620 100073 Tamper Switch for Compact Enclosure sss 620 100038 Tamper Switch for Metal Enclosure eren 2500 2347 PoE module ira eto rtm aio 620 100159 Lincar30W PoE nj ct r ui eee te he ere e tee reet POE PLUS Linear 12V DD O 24W derer lio ne ia 0 291312RU Linear 12VDC 60W PIP recommended power supply 0 299177RU Replacement Power Supervision Battery Charger Module 620 100002 For a replacement Controller please contact Nortek Security amp Control Sales for support at 1 800 421 1587 www linearcorp com 26 e3 eMerge Installation Instructions 30d o o E o o oj o o o 3nduj Jamod Ldf N x x 5 Od 8328 25 zoo 26r 3 4 GGG 0 BOE S25 coc gt lt gt lt LOVLNOO 4000 X38 aNo Q N9 1NdNI sani 19 12
30. port on the panel supports a 12VDC reader with Wiegand output format Readers can be installed as primary entry readers for each door as well as optional secondary exit readers Caution Improper power wiring will damage the fuse and void the warranty Minimum Cable Specifications Twisted shielded 22 AWG 250 ft or 18 AWG 500 ft Belden 89535 5 conductor or equivalent Please follow manufacturers installation requirements Note Wiring methods shall be in accordance with the National Electrical Code NPFA 70 and all local codes www linearcorp com The maximum power available for individual reader is 750 mA 12 VDC with a combined maximum of 1 5A for the controller Determine the reader s power consumption by referring to the documentation included with the reader Exceeding the maximum current for individual readers or for the controller will damage the protection fuses and void the warranty Wiring Readers 1 Remove power from the control panel Pull the reader wiring through a knock out in the panel s enclosure 3 Connect the color coded wires from the reader s wiring harness to the appropriate location of terminal strip as shown in Figure 6 1 4 Remove excess shield to ensure that it is not exposed An exposed shield can cause interference Tape off any exposed shield with electrical tape 12 LED CEN p 00700 TTT 1 LED SQQ QQOQG moo DEY or
31. th the National Electrical Code NPFA 70 and all local codes www linearcorp com 5 2 Wiring the Inputs All inputs may be configured for normally open factory default or normally closed contacts with supervision or non supervision Use standard 1k ohm resistors for supervision Refer to Figure 5 1 for the acceptable wiring configurations Resistor Value 1k Ohm Normally Open Normally Open io M c Normally Closed Normally Closed oeoo Figure 5 1 Input Circuit Configurations Tamper Protection A tamper switch is mounted inside the enclosure for connection to pin 5 and pin 6 on the terminal strip If the cover is removed for any reason the tamper switch will activate triggering a condition that can be linked to an event action in programming e g send an e mail or generate an output Factory Installed Tamper Figure 5 2 Tamper Input Wiring 13 e3 eMerge Installation Instructions 5 3 System Outputs All systems have door lock relays and auxiliary output relays that may be activated in response to reader activity time schedules or input conditions All relays are Form C SPDT and provide non powered dry contacts rated for 2A The number of available door lock relays and auxiliary output relays will depend on the number of licensed doors Output Defaults All outputs are assigned default features that can be configured as needed The following table shows the default states for each of the outp
32. ting Extensions If running surface wires 6 extension legs may be snapped onto the back of the enclosure to g gs may pP provide additional space behind the enclosure for the wires Figure 3 2 Mounting Feet Extensions for Compact Enclosure www linearcorp com 6 e3 eMerge Installation Instructions Note Choose a centrally located secure clean and dry area near an AC power source Avoid mounting the panel within 6 feet of any equipment that generates electrical interference Caution This equipment includes electronic components that are highly sensitive to static electricity Please discharge by touching an earth ground before installing or handling this equipment Note Tie down loops are located in the enclosure and used to provide strain relief for field connections www linearcorp com 3 2 Mounting the Metal Enclosure The metal enclosure is designed to accommodate one or two 12VDC 7Ah backup batteries and the necessary wiring connections for most installations Conduit knock outs are provided on all sides of the enclosure The enclosure should be mounted vertically on a wall in a secure location within normal temperature levels A minimum of 12 inches of space around all sides of the enclosure is recommended Installing the Panel 1 Run all necessary wires to the panel location 2 Remove the enclosure s cover by unlocking the door and disconnecting the ground wire The door may be lifted out of the hing
33. uts Table 5 2 Default Output States Output Default State Default Response 3 second unlock time in response to corresponding reader Door Lock Outputs Not Energized Single Pulse activity Reader 1 activates door 1 lock relay Aux Outputs Not Energized Single Pulse No default response Must be configured via programming Wiring Requirements The cable must be the proper gauge for the current load and should not be routed in parallel with other wiring especially high voltage or AC wiring Refer to the Table 5 3 for wiring recommendations Table 5 3 Recommended Wiring Requirements Wiring Gauges and Distance Total Amps Voltage AC or DC 14 16 18 20 22 12V 1500ft 1000ft 600ft 375ft 225 ft e 24 2000ft 12006 7500 4509 300ft 12V 800ft 500ft 300ft 200ft 100 ft 24V 1000 ft 600ft 400ft 200ft 150ft 12V 400ft 240ft 1500 90ft 60 ft an 24V 480 ft 300ft 180ft 120ft 70ft www linearcorp com 14 e3 eMerge Installation Instructions Caution Do not use the control panel s power supply for the locking device A separate power supply must be used Caution The diode or MOV must be installed as shown in the illustrations Failure to install these protection devices may damage the control board or erratic operation Note Wiring methods shall be in accordance with the National Electrical Code NPFA 70 and all local codes
34. www linearcorp com 5 4 Door Lock Outputs The door lock outputs can be configured to operate in fail secure or fail safe modes Wiring the Door Locks Connect locking devices to the door relay as shown in Figures 5 3 through 5 5 Refer to the door strike specifications to determine the appropriate voltage and configuration WARNING DO NOT USE THE CONTROL PANELS POWER SUPPLY FOR THE LOCKING DEVICE A SEPARATE POWER SUPPLY MUST BE USED CONTROL PANEL S DOOR LOCK RELAY 2 OVO Fail Secure DC Door Strike DIODE 1N4933 DC POWER OR i SUPPLY EQUIVALENT Figure 5 3 Fail Secure DC Door Strike without power door strike is locked CONTROL PANEL S DOOR LOCK RELAY Fail Safe DC Door Strike CI SC POWER DIODE 1N4933 OR gt SUPPLY EQUIVALENT Figure 5 4 Fail Safe DC Door Strike without power door strike is unlocked CONTROL PANEL S DOOR LOCK RELAY 102 Fail Secure AC Door Strike SS MOVSNRDSOK T d AC POWER m OR q SUPPLY EQUIVALENT 4 d Figure 5 5 Fail Secure AC Door Strike without power door strike is locked 15 e3 eMerge Installation Instructions 6 0 Readers 6 1 Wiring the Readers The control panel can accept up to 8 readers or keypads Each reader