1. Altistart 22 Soft Starter near heat radiating elements e Electrical current through the Altistart 22 Soft Starter will result in heat losses that must be dissipated into the ambient air immediately surrounding the soft starter To help prevent a thermal fault provide sufficient enclosure cooling and or ventilation to limit the ambient temperature around the soft starter If several soft starters are installed in a control panel arrange them in a row Do not stack soft starters Heat generated from the bottom soft starter can adversely affect the ambient temperature around the top soft starter Mounting 4 Schneider Connection Betvveen the Fan and the Altistart 22 Soft Starter Eny p Pm T hr l SS T amm x 1373 Elini m onan Pot E A ET i Km 12 mi il 14 1 EE 4 Le 15 oo af bk RS i A 1 bk 44 pi 1 8 Es J fetes TU E 1 i od H r m l r 1 Altistart 22 Soft Starter 2 Fan Wall mounted or Floor standing Enclosure with IP 23 Degree of protection Introduction To help proper air circulation in the soft starter grilles and forced ventilation can be installed Ventilation Grilles Forced Ventilation Unit 1 40C 104 F L Schneider Electric Product data sheet ATS22D88Q Connections and Schema Power Terminal Cage Style 1 Ground connection Power connect
2. Product data sheet Characteristics x S 797977 9 9 9 9 994594 Complementary ATS22D88Q soft starter A 1522 control 220V power 230V 22kVV 400 440V 45kVV Main Range of product Altistart 22 Product or component Soft starter type Product destination Asynchronous motors Product specific appli Severe and standard applications cation Component name ATS22 Network number of 3 phases phases Power supply voltage 230 440 V 15 10 Motor power kW 22 kW at 230 V 45 kW at 400 V 45 kW at 440 V Factory setting current 81A Power dissipation in W 66 W for standard applications Utilisation category AC 53A Type of start Start with torque control current limited to 3 5 In Icl nominal current 88 A connection in the motor supply line for stan dard applications IP degree of protection IP20 Assembly style With heat sink Function available Internal bypass Power supply voltage limits 195 484 V Power supply frequency 50 60 Hz 10 10 Network frequency 45 66 Hz Device connection In the motor supply line To the motor delta terminals Control circuit voltage 220 230 V 15 10 at 50 60 Hz Control circuit consumption Discrete output number 20 W 2 Discrete output type R1 Relay outputs 230 V running alarm trip stopped not stopped starting ready C O R2 Relay o
3. ion or use thereof Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein Transmission rate 4800 9600 or 19200 bps Max nodes number 31 Protection type Phase failure on line Thermal protection on motor Thermal protection on starter Marking CE Type of cooling Forced convection Operating position Vertical 10 degree Height 295 mm Width 145 mm Depth 207 mm Product weight 12 kg Environment Electromagnetic compatibility Conducted and radiated emissions conforming to IEC 60947 4 2 level A Damped oscillating waves conforming to IEC 61000 4 12 level 3 Electrostatic discharge conforming to IEC 61000 4 2 level 3 Immunity to electrical transients conforming to IEC 61000 4 4 level 4 Immunity to radiated radio electrical interference conforming to IEC 61000 4 3 level 3 Voltage Current impulse conforming to IEC 61000 4 5 level 3 Standards EN IEC 60947 4 2 Product certifications CCC CSA C Tick GOST UL Vibration resistance 1 gn f 13 200 Hz conforming to EN IEC 60068 2 6 1 5 mm f 2 13 Hz conforming to EN IEC 60068 2 6 Shock resistance 15 gn for 11 ms conforming to EN IEC 60068 2 27 Noise level Pollution degree 45 dB Level 2 conforming to IEC 60664 1 Relative humidity lt 95 without condensation or dripping wa
4. ions minimum and maximum wiring capabilities tightening torque IEC cable UL cable Power connections minimum required wiring section IEC cable UL cable mm Cu 70 C 158 F 1 AWG Cu 75 C 167 F 1 230 Vac control logic Inputs LI 24 Vdc 3 wire control 6 Schneier With Line Contactor Freewheel or Controlled Stop Connection in the motor delta winding in series with each winding Wiring ATS22 soft starters connected to motors with the delta connections can be inserted in series in the motor windings The following wiring requieres particular attention It is documented in the Altistart 22 Soft start soft stop unit user manual Please contact Schneider Electric commercial organisation for further informations Schneider Example A 400 V 110 kVV motor vvith a line current of 195 A nominal current for the delta connection The current in each vvinding is equal to 195 1 5 or 130 A The rating is determined by selecting the soft starter with a permanent nominal current ICL just above this current 8 Schneider Electric Product data sheet ATS22D88Q Performance Curves Motor Thermal Protection Cold Curves Curves t s 10000 1000 100 10 B A 1 0 5 Vin 112 415 200 250 300 350 400 450 5 00 5 50 600 650 7 00 7 50 8 00 A Class 10 B Class 20 C Class 30 Trip time for a Standard Application Class 10 3 5 In 32 s Trip time for a Severe Application Class 20 3 5 In 63s Tr
5. ip time for a Severe Application Class 30 3 5 In 95s Schneider o Motor Thermal Protection VVarm Curves Curves t s 10000 1000 100 10 EH A 1 0 5 liln 442 1435 200 250 3 00 350 400 450 500 550 600 6 50 7 00 7 50 800 A Class 10 B Class 20 C Class 30 Trip time for a Standard Application Class 10 3 5 In 16s Trip time for a Severe Application Class 20 3 5 In 32s Trip time for a Severe Application Class 30 3 5 In 48 s 10 mx ay
6. ter conforming to EN IEC 60068 2 3 Ambient air temperature for operation 10 40 C without derating gt 40 lt 60 C with current derating 2 2 per C Ambient air temperature for storage 25 70 C Operating altitude lt 1000 m without derating gt 1000 lt 2000 m with current derating of 2 2 per additional 100 m RoHS EUR status Compliant RoHS EUR conformity date 0938 Schneider Electric Product data sheet ATS22D88Q Dimensions Drawings Frame Size B Dimensions mim iri 295 11 6 Schneider Electric Product data sheet ATS22D88Q Mounting and Clearance Precautions Standards The Altistart 22 soft starter is compliant with pollution Degree 2 as defined in NEMA ICS1 1 or IEC 60664 1 For environment pollution degree 3 install the Altistart 22 soft starter inside a cabinet type 12 or IP54 Ay DANGER HAZARD OF ELECTRIC SHOCK EXPLOSION OR ARC FLASH ATS22 soft starters are open devices and must be mounted in a suitable enclosure Failure to follow these instructions will result in death or serious injury Air Circulation Leave sufficient free space to help the air required for cooling purposes to circulate from the bottom to the top of the unit Overheating To avoid the soft starter to overheat respect the following recommendations Mount the Altistart 22 Soft Starter within 10 of vertical Do not locate the
7. utputs 230 V running alarm trip stopped not stopped starting ready C O Minimum switching current Relay outputs 100 mA at 12 V DC Maximum switching current Relay outputs 5 A at 250 V AC resistive load cos phi 1 Relay outputs 5 A at 30 V DC resistive load cos phi 1 Relay outputs 2 A at 250 V AC inductive load cos phi 0 4 L R 20 ms Relay outputs 2 A at 30 V DC inductive load L R 7 ms Discrete input number 3 Discrete input type LI1 LI2 L13 logic 5 mA 4 3 kOhm Discrete input voltage 24 V lt 30 V Discrete input logic 141 LI2 LI3 positive logic state 0 lt 5 V and lt 2 mA state 1 gt 11 V and gt 5 mA Output current 0 4 1 Icl adjustable PTC probe input 750 Ohm Communication port protocol Modbus Connector type 1 RJ45 Communication data link Serial Physical interface RS485 multidrop Jan 17 2012 Schneider Electric The information provided in this documentation contains general descriptions and or technical characteristics of the performance of the products contained herein This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications It is the duty of any such user or integrator to perform the appropriate and complete risk analysis evaluation and testing of the products with respect to the relevant specific applicat