Home
User Manual in PDF - Shop-WiFi
Contents
1. Coordinator Information End Device Information f If necessary change the Wi Fi settings to use Wi Fi instead of Ethernet to connect to the network Network Setting hbi IP Address 192 168 1 17 E8 4E 06 11 54 B7 Date Time Choose SSID WPANHR_2 y Per Shared Key Time Setting Management Connection Mode uage Account Password Automatic Logout Time Initialize Save Restore Confirm the change ZigBee Status Coordinator Information End Device Information Important Be sure to note the IP address and keep in a safe place for future reference NF GO7 W User s Manual g If necessary change the Cloud server settings to use an alternate cloud service do not change these if using SentrolCloud Cloud Server Setti Network Setting MANAA IP 118 163 1 159 Ethernet Setting Wiki Settine Port 10010 Date Time AES Function Enabled Y Time Setting Management Language Account Password Automatic Logout Time Initialize Save Restore parade n ZigBee Status Coordinator Information End Device Information h Select NTP if using NTP or manually change the system time and time zone settings System Time and Time Zone Setting Network Setting NTPD Service Enable Ethernet Setting WiFi Setting NTP Server pool ntp org Cloud Server Setting Update Interval 24 Date Time Management uage Account Password Automatic Logout Time Initialize UTC 08 00 Taipe
2. Shon WiEi com NAF GO7 W User s Manual T ZigBee Control your world WF WEF Sor tr atewa s e D a y ka t A G07 W User s Manual Ver 1 01 4 30 2014 Copyright 2011 14 Nietzsche Enterprise Co Ltd All rights reserved Nietzsche Enterprise reserves the right to make changes and improvements to its products without notice Content 1 Package Content and GO7 W VIEWS ssessssssssersssreenssseressreressreressreressreresseeeeeseseseeesesreeee 2 2 Installing Mounting for GO7 W seesessesessssreessreereresssresreeesreresssenrerssererereseseeesreresesesrereseee 2 BY Pwan On GO WN are A E eee o A OAT SUM eNe a aA AE 4 5 Joining Sensors to the Gateway ccccccsccscsssssssssssssscessscessssesssssessesessssssssssssssessaeees LO 6 Removing Sensors from the Gatewa ccccsccssssccecesssscecscscsssscescesesssesesecseeeeeeseeeeeeseees 13 7 G07 W LED Status 8 Reset 9 Product Specificatio isisisi Aa 14 NF GO7 W User s Manual Congratulations for choosing NHR s ZigBee wireless controller gateway This manual is designed to help set up and get the most from the Gateway in a few short minutes Safety notice Please read and follow the instructions before using this product e To prevent electrical shock or fire do not disassemble or expose the unit to liquids of any kind e Only use attachments and or accessories specified by the manufacturer 1 Package Content and
3. c Enter the IP address of GO7 W default IP address is 192 168 1 100 into an Internet browser the default Username and Password is admin and admin Network Setting Ethernet Setting Cloud Server Settin Date Time Management Account Password Automatic Logout Time ZigBee Status Coordinator Information End Device Information ME lt 6 sentroicioud GatewayiNenSettino Username Password NA Nietzsche Enterprise Co Ltd O AF No 580 Sec 2 ChungShan Rd Chung Ho Dist New Taipei City 235 Taiwan STel 886 2 2223 1118 E E mail serice n comtw wwwnhecom tw d If necessary change the language to the desired language Language Setting Please select a language English Confirm the change G07 W User s Manual Important If using Microsoft IE be sure to use IE 10 or above to access If using Windows XP be sure to use Google Chrome NF GO7 W User s Manual e If necessary change the Gateway Name and Ethernet settings as appropriate if using static IP ensure the IP Address Subnet Mask and Default Gateway values are correct Ethernet Setting Network Setting Ethernet Setting IP Address 192 168 1 14 WiFi Setting MAC Address 44 70 38 00 00 1A4 Cloud Server Setting Date Time Gateway Name M0 Connection Mode Time Setting Management Language Account Password Automatic Logout Time Initialize Save Restore Upgrade ZigBee Status
4. Time Setting Management Automatic Logout Time Initialize Save Restore Uperade Reboot ZigBee Status Coordinator Information End Device Information k If it is necessary to reset GO7 W to factory default settings without having to physically press the reset switches on GO7 W 7 Back to the Factory Settings Network Setting i i l a Are vou going to restore your ZigBee Gateway to the factory default settings Ethernet Setting WiFi Settin Cloud Server Setting Date Time Time Setting Management Language Account Password Automatic Logout Time Save Restore Upgrade Reboot Confirm the change ZigBee Status Coordinator Information End Device Information Note GO7 W reset will result in all the settings including ZigBee network being restored to factory settings It is recommended to save these settings before reset if they are needed again see step m below ZigBee reset on GO7 W will result in all ZigBee devices on GO7 W s network to be disconnected it is recommended to remove the devices first from the network see Removing 9 NF GO7 W User s Manual Devices from G07 W otherwise each device will need to be individually reset before they can be joined to another network I If necessary save GO7 W s settings as a profile for later restore Upload Download your profile Network Setting Profile Browse Ethernet Setting WiFi Setting Cloud Server Setting Date Ti
5. Views of GO7 W NHR GO7 W Controller Gateway Mounting fixtures mounting plate 4 wall DC 12V Adapter plugs 4 screws Cloud DC 12V u Wi Fi LAN Standard A Status LED USB Sockets W Socket ZigBee Reset Ethernet Status LED Join Switch Socket A i Mounting Plate Unique MAC Prodtict Serial Access ZigBee Controller Gateway PW DC 12V RF 2 4GHz Barcode MUNN EN MIIEM 110 100 111 C MAC 24B000214A6C7 SIN 3B28 41170014 T 425 950 fet x Address i Number s Key NF GO7 W User s Manual 2 Installing Mounting for G O7W Requirements Mounting fixtures Drill with 5mm 0 2 inches drill bit size if using wall plugs or 3 5mm 0 14 inches drill bit size if not using wall plugs Size 1 Phillips screwdriver Long flat 4mm tool a Locate GO7 W within 1 0m of AC mains socket and with at least 15cm approx 6 inches spacing on each side except on mounting side avoiding the following direct sunlight gt 85 humidity RF interference especially 2 4GHz etc b If necessary pre drill mounting holes use mounting plate for alignment with the appropriate drill bit 5mm approx 0 2 inches if using wall plugs or 3 5mm approx 0 14 inches if not using wall plugs c If necessary first insert wall plugs into the 4 holes then use size 1 Phillips screwdriver to fasten the screws securing the mounting plate Note pay careful attention to the orientation of the mounti
6. Reboot ZigBee Status Coordinator Information End Device Information p If necessary the ZigBee coordinator s end device information for GO7 W can be displayed Display End Device Information Network Setting Ethernet Setting MAC ADDRESS SHORT ADDRESS WiFi Settin OOISEBOOODOACOTA Cloud Server Setting Date Time Time Setting Management Language Account Password Automatic Logout Time Initialize Save Restore Upgrade Reboot ZigBee Status Coordinator Information End Device Information 5 Enabling G07 W to Permit Join Other Devices to its Network 12 NF GO7 W User s Manual Requirements e Child device such as router eg STH MO2ZB WZB 01USBR WZB 02485R or end device eg STH 01 series STH MO2ZB STH 03ZB SO5 series WZB series safety and security devices e Sharp pointed tool a Ensure GO7 W is powered on see Powering On GO7 W and ready to accept the child device b Ensure child device s is in ready to join status see relevant device s manual c Using the sharp pointed tool apply 1 quick press to the ZigBee Reset Join switch on GO7 W the ZigBee LED will flash every 2 seconds for up to 60 seconds to permit join devices to its network d When a child device has joined GO7 W the ZigBee LED will show 2 quick flashes also check the status of the child device to confirm it has been connected see relevant device s manual e Repeat the above steps until all child devices h
7. ave been added successfully 6 Removing Devices from GO7 W Requirements e Child device such as router eg STH MO2ZB WZB 01USBR WZB 02485R or end device eg STH 01 series STH MO0O2ZB STH 03ZB SO5 series WZB series safety and security devices a Ensure GO7 W is powered on see Powering On GO7 W b Refer to the child devices manual to remove from parent network c When a child device has been removed from G07 W the ZigBee LED will show 5 quick flashes 7 GO7 W LED Status The table below shows the LED status for GO7 W Cloud LED ZigBee LED Status On On Power on test lasts around 30 seconds On Off Connected to cloud server Off Off Disconnected from not yet configured for cloud server 2 flashes Off Reconnect to cloud server 2 flashes then stays on Off Receiving commands from cloud server m AN a z j 13 NF GO7 W User s Manual ZigBee LED Status 1 flash every 2 seconds Permit join permit requests from devices routers sensors to join the network 2 quick flashes Device joined device router sensor joined or re joined the network 5 quick flashes Device removed device router sensor successfully removed from the network 8 Reset Requirements e Sharp pointed tool a ZigBee Reset To clear the ZigBee network completely use a sharp pointed tool to apply a 5 second press to the ZigBee link switch on GO7 W until the ZigBee LED comes on release the ZigBee Reset Join
8. i Save Restore Upgrade Reboot p Confirm the change Cancel ZigBee Status Gancet Coordinator Information End Device Information Note Manual adjustment is needed when there is daylight saving GO7 W User s Manual System Time and Time Zone Setting D NTPD Service Ethernet Setting Careri Tine CTM E E E E WiFi Setting Cloud Server Setting Network Setting Date Time Time Setting Management Language Account Password Automatic Logout Time Initialize UTC 08 00 Taipei Save Restore Uperade Reboot ae Confirm the change Cancel ZigBee Status Coordinator Information End Device Information i It is recommended to change the username and password from the default to something more appropriate default Username and Password is admin and admin Network Settin g Set the Password Ethernet Setting WiFi Setting Cloud Server Setting Confirm Password Date Time Time Setting Management Language Account Password Automatic Logout Time Initialize ave Restore Upgrade Reboot Confirm the change ZigBee Status Coordinator Information End Device Information j It is recommended to set an automatic logout time to ensure GO7 W settings are not opened to changes from unauthorized personnel GO7 W User s Manual Set Automatic Logout Time Automatic logout time Bo O O seconds Network Setting Ethernet Setting WiFi Setting Cloud Server Setting Date Time
9. me Time Setting Management Language Account Password Automatic Logout Time Initialize Save Restore Upgrade Reboot ZigBee Status Coordinator Information End Device Information 10 Ni m GO7 W firmware can be upgraded on this screen Network Setting Ethernet Setting WiFi Setting Cloud Server Setting Date Time Time Setting Management Language Account Password Automatic Logout Time Initialize Save Restore Upgrade Reboot ZigBee Status Coordinator Information End Device Information n If necessary GO7 W can be rebooted without physically power cycling Network Setting Ethernet Setting Wiki Setting Cloud Server Setting Date Time Time Setting Management Language Account Password Automatic Logout Time Initialize Save Restore Upgrade ZigBee Status Coordinator Information End Device Information Upgrade the firmware GO7 W User s Manual Gateway Firmware Version 03 40 Internet Upgrade Reboot Would you like to reboot your ZigBee Gateway 11 NF GO7 W User s Manual o If necessary the ZigBee coordinator s information for GO7 W can be displayed Display Coordinator Information Network Setting Ethernet Setting Zigbee Mac 00124B000214A80F WiFi Setting PAN ID FIAG Cloud Server Setting CHANNEL fc E Date Time Time Settin Management Language Account Password Automatic Logout Time Initialize Save Restore Uperade
10. ng plate d Install and remove using long flat tool GO7 W as follows to ensure the mounting plate has been correctly and securely installed and GO7 W can be installed and removed Install Remove Press release using long flat tool U Lihis ger f ZigBee Controller Gateway tMi n nance i M CE Initial hardware installation for GO7 W has been successfully completed Ni 3 Powering On GO7 W Requirements e DC12V adapter e Ethernet cable GO7 W User s Manual a For first time power on and configuration or if using Ethernet for networking to the cloud connect the Ethernet cable to the Ethernet port on GO7 W and to configuring computer or the network b Connect DC 12V adapter s DC jack into GO7 W and plug adapter into live mains socket c The Cloud and ZigBee status LEDs on GO7 W will indicate its current state Cloud LED ZigBee LED On On On Off Off Off 2 flashes Off 2 flashes then stays on Off G 07W has been successfully powered on 4 Configuring GO7 W Settings Requirements e Ethernet Cable e Internet browser software e Computer PC or Mac Status Power on test lasts around 30 seconds Connected to cloud server Disconnected from not yet configured for cloud server Reconnect to cloud server Receiving commands from cloud server a Connect GO7 W to a computer using an Ethernet cable directly b Ensure GO7 W is powered on see Powering On GO7 W Ni
11. switch and the ZigBee LED will remain on for 3 seconds then go off to indicate reset Note ZigBee reset on GO7 W will result in all ZigBee devices on its network to be disconnected it is recommended to remove the devices first from the network see Removing Devices from G07 W otherwise each device will need to be individually reset before they can be joined to another network b Gateway Reset To reset GO7 W to factory settings excluding ZigBee network use a sharp pointed tool to apply 5 second press to the WiFi LAN Reset switch on GO7 W both the Cloud and ZigBee LEDs will flash 3 times to indicate reset then both LEDs will stay on for the power on sequence Note Gateway reset on GO7 W will result in all the settings excluding ZigBee network being restored to factory settings It is recommended to save these settings before reset if they are needed again 9 Product Specifications Wireless Compliant IEEE 802 15 4 ZigBee2007 PRO HA Profile 2 4GHz ISM band Transmission Range 500m 1640ft line of sight RF Output Power 18dBm Power Supply DC 12V Adapter Operating Environment 10 60 C lt 80 relative humidity Power Consumption TX 300mA Network Topology Star Tree Mesh Dimensions 189 L x 175 W x 35 H mm including antenna Weight 229 6g 8 100z excluding power adapter Certifications CE FCC Shop Wiki com Wireless caoammuoarcatrfean productis
Download Pdf Manuals
Related Search
Related Contents
(表紙〜P.95(P.96白紙))(PDF:2817KB) la courneuve modernise son - Centre interdépartemental de gestion Gigaset DE900 IP PRO – Plus qu`un simple téléphone 取扱説明書 - 今仙技術研究所 CENTRÍFUGA NO REFRIGERADA(2) PROTECTA™ VR D364VRM - Medtronic Manuals: Region Userguide HMD - Petri Konferenztechnik HDW-M2100 HDW-M2100P Droits Préférentiels de Souscription (DPS) Mode d`emploi Copyright © All rights reserved.