Home
STH-M02ZB User`s Manual (ZigBee HA Profile) Ver. 1.03
Contents
1. 2 flashes every 3 seconds Status Ready to join ready to join network of parent device coordinator gateway or router Successfully joined joined network of parent device Normal Operations joined network of parent device and functioning normally Permit join permit requests from other devices routers sensors to join the network Blue LED Disconnected joined network but unable to find any 2 flashes every 5 seconds parent device of the network Red LED Device joined device router sensor joined to the 2 flashes one time network Red LED Device removed device router sensor successfully 3 flashes one time removed from the network Red LED Removing being removed from the network of the parent rapid flashing up to 30 seconds device Blue amp Red LED ZigBee Reset reset to factory default remove all ZigBee ON network linkages 9 ZigBee Reset In the case where the parent devices coordinator gateway or router for STH MO2ZB are no longer available or have been reset STH M02ZB will need to be reset by applying a 5 second press to the link switch the blue amp red LEDs will both come on during the reset then the blue LED should show ready to join status flash once every 5 seconds Recommendation Before removing power from STH MO02ZB removing it from the network or resetting please ensure its router capability is no longer needed on the network by child device s
2. 5mm approx 0 2 inches if using wall plugs or 3 5mm approx 0 14 inches if not using wall plugs c If necessary first insert wall plugs into the 2 holes then use size 1 Phillips screwdriver to fasten the screws securing the mounting cradle Note pay careful attention to the orientation of the mounting cradle d Install and remove STH MO2ZB using the following 2 step action to ensure the mounting cradle has been correctly and securely installed and STH MO02ZB can be installed and removed For installation using the built in hanging fixture b If necessary pre drill mounting hole with the appropriate drill bit 5mm approx 0 2 inches if using wall plugs or 3 5mm approx 0 14 inches if not using wall plugs c If necessary first insert the wall plug then use size 1 Phillips screwdriver to fasten the screw leaving 2mm 0 08 inches protruding for seating STH M02ZB s built in hanging fixture d Hang and remove STH M02ZB on the protruding screw to ensure it can be installed and removed 3 NA STH MO2ZB User s Manual Initial hardware installation for STH M027B has been successfully completed 3 Powering On STH M02ZB Requirements e DC5V USB adapter and cable a Connect USB cable s Standard A plug to DC 5V USB adapter and plug into live AC Mains socket b Connect USB cable s Micro B plug to STH M02ZB c The status LED on STH MO2ZB should start flashing to indicate its current state Blue LED Status 1 f
3. MO2ZB User s Manual If STH M02ZB has joined successfully but the blue LED flashes twice every 5 seconds disconnected then check parent device is correctly powered on If the parent device is functioning correctly STH M02ZB may be out of range or experiencing interference additional router s may need to be added to ensure good connections 5 Enabling STH M0O2ZB to Permit Join Other Devices to its Network Requirements e Child device such as router eg STH M027ZB WZB 01USBR WZB 02485R or end device eg STH 01 series STH M02ZB STH 03ZB SOS series e Sharp pointed tool a Ensure STH M02ZB is powered on see Powering On STH M02ZB and has already joined the parent s network blue LED flash twice every 5 seconds b Ensure child device s to be joined to STH M02ZB s network is in ready to join status see relevant device s manual c Use a sharp pointed tool to apply 1 quick press to the link switch on STH MO2ZB the blue LED will flash twice every 3 seconds for up to 60 seconds to permit join other devices to its network d If a child device has successfully joined STH MO2ZB s network the red LED should flash twice 6 Removing STH M02ZB from the Parent s Network Requirements e Sharp pointed tool a Ensure parent device is powered on see relevant device s manual b Ensure STH MO2ZB is powered on see Powering On STH M02ZB and has already joined the parent s network blue LED flash
4. Once STH MO2ZB has been removed from the network or reset it is suggested to remove power from the STH M02ZB when not in use to reduce power wastage RF traffic and unintentional joining to original or new network NR STH MO2ZB User s Manual 10 Product Specifications O 40 C lt 85 relative humidity
5. ma RER DER 35 Seconds 35 Minutes 40 Seconds Je M M CE 40 Minutes E oN m 45 Seconds 45 Minutes o E ce T o E 50 Seconds 50 Minutes ON E ON a ON ul 4 ron El Le ON E 4 ON a 4 ON 5 ON fa 4 ON A 4 ON a 4 on a 4 o mn M l o om om o o o M ll JE E o E O z 55 Seconds 55 Minutes 60 Seconds 60 Minutes 65 Minutes E E E 1 TW o E 65 Seconds E E ee E o E o E 70 Seconds 70 Minutes M mo mo MO mo 9 mo mo mo MO m9 mmol i mo mmol 4 mo 75 Seconds 75 Minutes gt c Ensure STH MO2ZB is joined to a parent device see Joining STH M02ZB to the Network d Use software for reading information from coordinator or gateway device see relevant device s manual to confirm STH M02ZB transmissions are being received at the correct interval e If necessary replace STH MO0O2ZB into its mounting see Installing mounting for STH M02ZB Transmission interval setting has been successfully configured Note Transmission interval is read at power on a power cycle is required to effect interval change Nii 8 STH M02ZB LED Status STH MO2ZB User s Manual The table below shows the LED status for STH MO2ZB LED Sequence Blue LED 1 flash every 5 seconds Blue LED 3 flashes one time Blue LED 1 flash every 2 seconds Blue LED
6. twice every 5 seconds c Use a sharp pointed tool to apply 3 quick presses to the link switch on STH M02ZB the red LED will flash rapidly for up to 30 seconds or until successful removal d If STH M0O2ZB has been successfully removed the blue LED should flash once every 5seconds Recommendation Before removing STH M02ZB from the network please ensure its router capability is no longer needed on the network by child device s Once STH M02ZB has been removed from the network it is suggested to remove power from the STH MO02ZB when not in use to reduce power wastage RF traffic and unintentional joining to original or new network NA STH MO2ZB User s Manual 7 Setting Transmission Interval for STH M02ZB a If necessary remove the STH M02ZB from its mounting see Installing Mounting for STH M02ZB b Set the transmission interval using switches 4 8 based on the following DIP switch positions Transmit Interval DIP Switch Setting Transmit Interval DIP Switch Setting 1 Second 1 Minute m a a 5 Minutes gt E O lal re a mo a mo 5 Seconds om om o M 10 Seconds 10 Minutes a CE a of M 15 Minutes 20 Minutes 15 Seconds a Cm om ecm ms om moll a 2 o M 20 Seconds om om om 25 Minutes 30 Minutes 25 Seconds om o E E os oW o m CE a a E 30 Seconds a om om om o RER M om o
7. Ni 1 2 3 4 5 6 7 8 9 LigBee Control your world a STH M02ZB User s Manual ZigBee HA Profile Ver 1 03 Copyright 2011 14 Nietzsche Enterprise Co Ltd All rights reserved Nietzsche Enterprise reserves the right to make changes and improvements to its products without notice Contact Information Email service nhr com tw Website www nhr com tw Content Package Content and STH MO2ZB Views sise Installing Mounting for STH MO2ZB is Powering On STH MO2ZB scjacscietvncssiipsicinrictsaiiuselawieety abv pendent e a aa ie ee saii Joining STH M02ZB to the Network ins Enabling STH M02ZB to Permit Join Other Devices to its Network sesssscsceses Removing STH M02ZB from the Parent s Network essesessssesssseresesesreeseseereseseseseseeee Setting Transmission Interval for STH M02ZB ST 1162224 LER UNS e E E an dane aanasocevaamesnsuceuendesesannaigtavaneeats AOB ORES ON en a ha ic ed ne 10 Product SpecilicatioNS nan ananas sa es isonadesenatades STH MO2ZB User s Manual NA STH MO2ZB User s Manual Congratulations for choosing a world class digital temperature and humidity sensor using ZigBee wireless transmission technology This manual is designed to help set up and get the most from the sensor in a few short minutes Safety notice Please read and follow the instructions before using this product e To prevent electrical shock or fire do not disassemble or expose the unit to liqu
8. ids of any kind e Only use attachments and or accessories specified by the manufacturer 1 Package Content and STH M02ZB Views NHR STH MO2ZB digital temperature and Mounting fixtures mounting cradle 2 wall DC 5V USB Adapter humidity sensor plugs 2 screws and Cable ree J NA Il OU SE fe Emm IHIH game FS ELLE gt f Lam _ m m If any of the above is missing please contact your supplier Front Bottom NA O status LED gt Temperature amp m lt lt USB Micro B Socket p lt Humidity Sensor Side Back 1 y Built in Hanging Fixture NA ll STI ne onee Tr Product Serial Number amp Le em Unique MAC Address ET Link Button i i Transmission Interval REFIR Setting Switches NA STH MO2ZB User s Manual 2 Installing Mounting for STH M02ZB Requirements e Mounting fixtures e Drill with 5mm 0 2 inches drill bit size if using wall plugs or 3 5mm 0 14 inches drill bit size if not using wall plugs e Size 1 Phillips screwdriver a Locate STH MO02ZB within 1 0m of AC mains socket and with at least 15cm approx 6 inches Spacing on each side except on mounting side avoiding the following sources of interference direct sunlight air flow from vents fans doors windows heaters sources of steam oil vapor etc For installation using the mounting cradle b If necessary pre drill mounting holes use mounting cradle for alignment with the appropriate drill bit
9. lash every 5 seconds Ready to join a parent device 1 flash every 2 seconds Already joined a parent device and functioning normally 2 flashes every 5 seconds Already joined but unable find a parent device in the same network STH MO02ZB has been successfully powered on Recommendation It is strongly recommended to power on STH MO2ZB just before joining to parent device or when required as this will reduce power wastage and RF traffic 4 Joining STH M02ZB to the Network Requirements e Parent device such as coordinator eg WZB 01USBC WZB 02485C gateway eg GO7 W WZB O5ET or router eg WZB 01USBR WZB 02485R e Sharp pointed tool a Ensure parent device is powered on see relevant device s manual b Power on STH MO2ZB ensuring it is in ready to join status blue LED flash once every 5 seconds c Enable permit join status on parent device see relevant device s manual and check STH M027B joined the parent device d If STH MO2ZB has successfully joined the parent device the blue LED should flash 3 times then once every 2 seconds If STH MO02ZB s blue LED does not flash once every 2 seconds then it has not successfully joined Repeat above steps until STH M0O2ZB has joined successfully If STH MO0O2ZB has still not joined after a few attempts check it is within the operational range of 100m line of sight from the parent device and away from other 2 4GHz devices that might interfere with its operations 4 NA STH
Download Pdf Manuals
Related Search
Related Contents
Pinnacle Trigger Finger PULSEBOX NxtG - AxeMotion CNC Controller Franke FHM 604 4G OA E Mode d`emploi Balances d`analyse et de précision 1" Valve Stab User Manual 中日文化センター L`homme de ma vie : le trouver, le garder - Sommaire et MELSEC iQ-R Inter-Module Synchronization Function Reference Here - Biglobe Owner`s Manual - 1800customersupport.com Copyright © All rights reserved.