Home

Dual Slide LCD KVM User`s Manual

image

Contents

1. lt Enter gt the unlock security window will be shown on the screen Unlock Serial 212133213211 Unlock PSWD admin PSWD or Plus in dongle Figure 27 Please contact the dealer and impart the Unlock Serial to dealer for information The dealer will tell you the Unlock PSWD according to your Unlock Serial Y Adminstrator Reset Key Generator Unlock Serial 0143093068 Unlock Password 10900721 BOYD Figure 28 e Input the Unlock PSWD from your dealer unlock Serial 212133213211 Unlock PSWD 3231 12311312 admin PSWD or Plus in dongle Figure 29 After entering the correct Unlock PSWD you must input enrolled password or plug in the dongle of administrator Unlock Serial 212133213211 Unlock PSWD 323112311312 admin PSWD or Plug in dongle Figure 30 e f both of the above verification steps has been completed you will enter the OSD main menu as the administrator You can register a new password or security dongle for administrator 43 9 Sun Microsystems Function Key Emulation There are 16 special functions on the Sun Microsystems keyboard Combo Free KVM Switch can emulate these function keys via PS 2 and or USB keyboard Please refer to the table shown below for Sun Microsystems keyboard special functions operation To activate these emulation on the PS 2 and or USB keyboard you have to press the lt LEFT Windows key first this key usually is located
2. LED Power Green Security Red Power Switch Pe ES Support Extra USB Keyboard amp USB Mouse console Ports Extra USB Console 3 2 3 Back View Reset Firmware Upgrade USB amp PS 2 PC Link If Firmware Upgrade is necessary please contact your dealer for further assistance and information 3 3 System connection 3 3 1 System connection Please use Custom combo cable to connect your computers Please refer to the figures and instruction shown below for System connection Note Please contact your dealer to purchase the custom combo 4 1 cables if you need Figure 1 Custom combo 4 in 1 cable 3 3 2 Rack Mounting Figure 2 Rack mounting Figure 6 shows you how to attach mounting brackets to the KVM Switch unit for standard 19 inch rack cabinet 1 Screw the mounting brackets into the sides of the KVM Switch unit See Figure 6 2 Install the KVM Switch unit into the rack cabinet You can connect KVM switch to computers via three methods shown below A Connect USB PS 2 keyboard mouse and VGA connectors to computers We recommand users to connect computers in this way Figure 3 Cem MESAN y Wo Figure 3 USB amp PS 2 Keyboard amp Mouse and VGA connected B Connect only PS 2 keyboard mouse and VGA connectors to computers Figure 4 aN MENN y g Weg mm mmm Es
3. M y A e PRA Ls A Figure 4 PS 2 Keyboard amp Mouse and VGA connected C Connect only USB and VGA connectors to computers Figure 5 Se ON y y WZ ests m e e cEBocEBe Si TOG SS Figure 5 USB and VGA video connected 3 3 3 Cascade Chaining Combo Free 8 port 8 16 port KVM switch support 3 level cascades control up to 64 256 4096 PCs from a single console cascaded units don t need special configuration Cascade configuration expands system ability and allows you to select computers connected to the Master or Slave After connected KVM Switches automatically configure Master and Slave To Install cascade chain please follow the instruction below A Please turn off computers and devices when you start to install KVM Switch B Use the custom combo cable set See Figure 1 to connect one or more Slave KVM Switches to any PC port of Master KVM Switch The connection between KVM to KVM must be connected through PS 2 connection Please refer to Figure 2 8 Figure 3 C You can do console Master KVM Switch via either USB and or PS 2 keyboard and mouse at will D Plug in the power adapter of the first level Master KVM Switch and connect Master KVM switch to computers Next plug in power adapter for each level Slave KVM Switch and connect Slave KVM switch to computers The power on sequence should be 1 Ma
4. channel by lt ALT gt key Press left lt ALT gt or right lt ALT gt key twice the PC channel will 26 automatically shift to left or right one channel channel decrease increase to next when lt ALT gt channel shift function is enabled gt Enable Disable lt ALT gt channel shift function lt Scroll Lock gt lt Scroll Lock gt lt ALT gt lt Enter gt gt Switch to left one channel lt Left ALT gt lt Left ALT gt gt Switch to right one channel lt Right ALT gt lt Right ALT gt 6 4 Channel Select Cascade Chain Layer You can select the active channel directly under cascade chain connection The following hot key sequence is used for quick channel selection Press lt Scroll Lock gt twice lt D gt the cascade channel number 1 2 3 16 and Press lt Enters gt gt Channel select to first layer lt Scroll Lock gt lt Scroll Lock gt gt lt D gt lt CH L1 gt lt Enter gt gt Channel select to second layer lt Scroll Lock gt lt Scroll Lock gt gt lt D gt lt CH L1 gt gt lt D gt gt lt CH L2 gt lt Enter gt gt Channel select to third layer lt Scroll Lock gt lt Scroll Lock gt gt lt D gt lt CH L1 gt lt D gt lt CH L2 gt lt D gt gt lt CH L3 gt lt Enter gt Y Note With cascading 3 layers you can select last layer directly Example press
5. later sections The list of control functions F1 Set up basic set up menu F2 Scan autoscan function F3 Lock setup lock unlock only available when F5 Security is enabled F4 Rename rename selected channel name F5 Security security function and user authority settings F6 Lock Port PC port lock function for administrator only 7 2 Channel selection in OSD 7 2 1 7 2 2 Channel select to computer Use the lt UP gt and lt DOWN gt arrow keys to highlight a computer and then lt ENTER gt to select it and leave OSD menu A banner with the channel name will be shown on left upper corner of the screen 01 Channel 1 uN TES ES L Channel Name S Channel Number Fig 12 Channel Banner Single Layer Channel select to cascade port A plus mark showing in the left of channel name indicates that the port is under cascade channing Pressing lt ENTER gt in this channel will enter one level down and the screen pops up the listing of the computers of the slave KVM 32 01 03 0 Channel 1 L Channel Name T A O O Channel Number 2 aver Channel Number _____ 1 Layer Channel Number Fig 13 Channel Banner Cascade Layer 7 2 3 Return from cascade port After entering cascade port press lt R gt will return to upper layer OSD menu 7 3 Setup in OSD lt F1 gt Please use lt Up gt or lt Down gt arrow key to select the item you want to change and use lt Left gt or lt
6. All In one LCD Drawer Dual Slide with 8 16 port KVM Combo Free User s Manual INTRODUCTION oia id laricid 2 EOS A E A OO cena eaten ataatdenke famabeneseacacadeech ecueacadl AS E e ETE O ETEA EE AE EEA E T chase PoPa COn N er E E dad 4 2 SPECIFICATIONS ota AS A A A RS 5 A A A II A A AAA 5 3 CONNECTING ALL IN 1 SINGLE RAIL LCD CONSOLE DRAWER oooccocccccccccccccccccccccccccnos 6 3 1 CONFIGUARATION DIAGRAM OF CONNECTIONS ccceeccccccccccccuccecceceucuuccecececeuaeceeeeessnnunuueeeees 6 SC OMPONE NS e una or colo rauidss Dosis 7 33 OYO TEM CONNEC TION courdsstunetos necio antonia arica tania nanneuesaueaaek E 10 4 INSTALLATION oia id ii A lass Secasecesndals bien a a Laaa 15 5 MODULARIZED COMPONENTS REPLACEMENT cccccccccccccccccccccccccccccccccccccccccccecece 21 5 1 LCD PANEL MODULE REPLACEMENT ccccccccccecccccccccccceucccccceueceeeenuuuueeseeeeees 21 5 2 KEYBOARD MODULE REPLACEMENT cccccccccccccccecccccccccccuuuuuccceeessenuuuueatseess 22 GHOT KEY OPERATION siria diia 23 E all OS tN Cesena UN A III 25 6 2 Leading Hot Key SeleCt ccc cece cece cece eee eee e eee e eee O A eee e ae Sate E ee ae Sa se Ea EEG EEG E EEE EES 25 6 3 Channel Select Single KVM cc cette hen jas 25 6 4 Channel Select Cascade Chain Layer ccc ccc cce eee ce ence eee e eee ee teat ea eeeeeeaeeeeeeaeeaeeeeaes 27 6 5 Buzzer sound Disable ENadble iicini id 28 6 6 AUlO OC all FUNCIO
7. Hot Key Select 7 3 6 Sound gt ON Buzzer sound enabled gt OFF Buzzer sound disabled Note You can also enable disable buzzer sound via hot key by using lt Scroll Lock gt gt lt Scroll Lock gt lt B gt lt Enter gt outside the OSD mode Please refer section 6 5 Buzzer sound Disable Enable 7 3 7 Language English En Deutsch De Francais Fr 3 languages are available 7 4 Auto Scan in OSD lt F2 gt 7 4 1 Start to auto scan in OSD Press lt F2 gt in OSD main menu The auto scan banner will be shown to indicate the scanning channel SCAN 01 Channel 1 AA A A Channel Name a Channel Number E Indicate now is Scan Mode Figure 17 Auto Scan Banner Note You can also start auto scan function via hot key by using lt Scroll Lock gt lt Scroll Lock gt gt lt S gt lt Enter gt outside the OSD mode Please refer section 6 6 1 Start Auto Scan Function 7 4 2 Stop auto scan Press any key on keyboard to STOP the auto scan function The auto scan banner will disappear when the scan stops 35 7 4 3 Auto scan mode There are two auto scan modes please refer section 7 3 1 Setup in OSD Scan Mode to set up the auto scan mode gt Scan all computers which are power on gt Scan all computers which are marked for auto scan 7 4 4 Auto scan time interval The auto scan time interval of each port displayed can be adjustable by pressing lt F1 gt in OSD main
8. Module Screw Zz 23 Step 2 Disconnect K B and M S Connectors MIS PC Board Connector K B PC Board Connector 24 6 Hot Key Operation 6 1 Call OSD Menu Press lt Scroll Lock gt twice and lt Enter gt then the OSD Main Menu will be displayed on the monitor screen All of the KVM parameters can be setup in OSD mode You can also execute some KVM functions in OSD lt Scroll Lock gt lt Scroll Lock gt lt Enter gt 6 2 Leading Hot Key Select The two steps hot key sequence is used for quick function execution The leading key is lt Scroll Lock gt by default However you can change the leading hot key if you want By pressing lt CTRL gt twice lt New Hot Key gt then press lt Enter gt you can change the leading hot key The available leading hot key are lt Scroll Lock gt lt Num Lock gt or lt Caps Lock gt for option gt Setup leading hot key to lt Scroll Lock gt lt CTRL gt lt CTRL gt lt Scroll Lock gt lt Enter gt gt Setup leading hot key to lt Num Lock gt lt CTRL gt lt CTRL gt lt Num Lock gt lt Enter gt gt Setup leading hot key to lt Caps Lock gt lt CTRL gt gt lt CTRL gt lt Caps Lock gt lt Enter gt Note You can also change leading hot key by pressing lt F1 gt in OSD main menu Please refer section 7 3 5 Setup in OSD Hot Key 6 3 Channel Select Single KVM 6 3 1 Speci
9. N cri wtace detainee oun ian co o bit 28 6 7 GOMSOle HOC Kasai pce a talas dais 30 7 OSD OPERATION do lisas 30 AOSD Man Mena ele e EOS 30 722 Ghammel selection IN OSD ins it id OS a a ea 32 Te OCIUD I OOD aF a E EEA r 33 TA PHO SCAM MOS lt gt a ia aaa 35 FO GOnsole LOCK INOS Ds lt A iach chateecieue tw ootuug asec ade obad uence wenden deoratiaets 36 LO Ghannelrename Piso AS a ea an ote 37 TA OCCU SCUD eP Sarane dica 37 do a FEO O II A EN A A AS 40 TECOS DE ESOS id lid EE o al o LIA TOR O 40 9 SYSTEM SECURITY oa A A A A ances 41 SV MOGK THES YS TEM dal ios 41 Se UNLOCK THE SYSTEM anaa ia ol 41 8 3 RESET THE ADMINISTRATOR SECURITY LOCK cccceeeeeceecccccecccccceeceeuununnnnnanass 42 9 SUN MICROSYSTEMS FUNCTION KEY EMULATION o occccccocccccccoccccccccccccccccnccccoccccnonos 44 1 Introduction 1 1 Thanks for your purchasing the All in one LCD Drawer Single Slide with 8 16 port KVM Combo Free We recommend that you read this manual thoroughly and retain it for future reference Overview The All in one LCD Drawer Dual Slide with 8 16 port KVM Combo Free is an ideal module solution featuring an integrated 17 19 inch TFT LCD color display and ultra high quality compact industrial keyboard touch pad in 1U rack mountable format providing a user friendly and most reliable operation environment for server administrators Moreover user now have a high quality durable system to control 8 or 16 comp
10. Right gt arrow key to change the settings Press lt ESC gt to exit and save the setup settings Scan Mode Select scan T ime 3 00556 Banner Time 005Se Position Menu Banner Hot Scroll Lock fa i ON Language English En Figure 14 OSD Setup 7 3 1 Scan Mode gt Select scan the selected channels marked with S in STA column on OSD main menu gt PCON scan all powered on PC channels 33 7 3 2 Scan Time The default scan time is 5 seconds lt can be changed up to 90 seconds by stepping 5 seconds 7 3 3 Banner Time The default banner time is 5 seconds It can be changed to 10 seconds 15 seconds or always on 00 7 3 4 Position gt Menu Use four arrow keys to move the OSD main menu to the desired position Press lt ESC gt to save the changed menu position Position Menu Figure 15 Menu Position Setup gt Banner Use four arrow keys to move the channel banner to the desired position Press lt ESC gt to save the changed banner position lt gt to move Esc save return Figure 16 Banner Position Setup 7 3 5 Hot key gt Scroll Lock lt Scroll Lock gt becomes the hot key gt Num Lock lt Num Lock gt becomes the hot key gt Cap Lock lt Cap Lock gt becomes the hot key 34 Note You can also change leading hot key via hot key by using lt CTRL gt lt CTRL gt lt New Hotkey gt lt Enter gt outside the OSD mode Please refer section 6 2 Leading
11. back to normal status Note You can also execute console lock function by pressing lt F3 gt in OSD main menu Please refer section 7 5 Console Lock in OSD OSD Operation OSD Main Menu Press lt Scroll Lock gt twice and lt Enter gt then you will enter to OSD On Screen Display main menu The channel number names and the status will be displayed on the monitor screen Please refer fig 8 H Name File Server Mall Server Web Serveri RD Switch AC Switch Web Server2 CHI Server hb Digidffice Fig 11 OSD main menu 7 1 1 KVM layer number 1 2 or 3 indicates the current cascade level 30 7 1 2 gt gt gt 7 1 3 gt Channel name The channel name can be defined by using function key F4 it can remind user which computer is connected to this channel A highlighted pink bar is shown in the selected channel row A plus mark showing in the left of channel name indicates that the port has cascades Computer amp KVM status KVM buzzer stauts 4 Buzzer sound on xX Buzzer sound off Logined user name The system has one administrator and 3 users for security management The name of current logined is displayed here Channel LOCK indicator Status STA L Indicating this channel is locked BLANK Indicating this channel is normal without locked Computer power on indicator Status STA OSD menu will update the flag automatically if the computer status is changed A Indicating this computer
12. between the lt LEFT CTRL gt and lt LEFT ALT gt Then press the second key Sun Microsystems Function Key Please do not release lt LEFT Window gt when you press the second key Sun Microsystems Function Ke USB or PS 2 Keyboard L Win amp L_Alt L Win L_Ctrl Compose L Win L_Shift Front L Win amp F1 Open L Win amp F2 Find L Win amp F3 Again L Win amp F4 Undo L Win amp F5 Copy L Win F6 Paste L Win amp F7 Cut L Win amp F8 Help L Win amp F11 Power L Win amp F12 Mute L Win 4 1 Volume Down L Win amp 2 Volume UP L Win 3 44 Disclaimer Information in this document is subject to change without notice The manufacturer does not make any representations or warranties implied or otherwise regarding the accuracy and completeness of this document and shall in no event be liable for any loss of profit or any other commercial damage including but not limited to special incidental consequential or other damages No part of this document may be reproduced or transmitted in any form by any means electronic or mechanical including photocopying recording or information recording and retrieval systems without the express written permission of the manufacturer All brand names and product names used in this document are trademarks or registered trademarks of their respective holders FCC Statement This device generates and uses radio frequency and may cause interference to radio and tel
13. d the package If you encounter any problem please contact your dealer 2 Make sure that power to all the devices you will be connecting to has been turned off You must also unplug the power cords off any computers that have the Keyboard Power On Function Installation Step 1 Install the Left Rail on Cabinet Step 2 First drive the screws loosely through the front bracket of left rail on cabinet Try not to tighten the screws too much so that later it will allow you some wiggle room to align the holes in a correct orientation And this will make easy insertion of the long bolt which serves as an anchor to limit the sliding range of the rails Step 3 Screw and tighten the back bracket of left rail on cabinet 16 Step 4 Tighten 4 screws on the left rails outside as photo shown Step 5 Tighten 4 screws on the left rails inside as photo shown 17 Ke Step 6 Install the Right Rail on the cabinet Note Please follow the same procedures as Step 1 5 for the installation of the Right Rail Step 7 Please check if the Rails are secured and attached to cabinet firmly 18 i ARAAAAA Aa IAN g Step 8 Slide the LCD Console Drawer into the Rails and push it further to the end Step 9 Take out the 2 stopper bars each of which is comprised of a long screw and a cage nut on the end and install each of them through the central holes on both the left and t
14. e File Server Mail Server Web Serverl RD Switch AC Switch Web Servera CHI Server DigiOffice Figure 26 Lock port in OSD main window 7 8 2 Channel selection of the locked port If anyone selects the channel of the locked port either by panel push button or hot key the system will enter OSD mode waiting for administrator to unlock the port 7 8 3 Unlock Port Only administrator login with correct password can unlock the port After the administrator login the red L mark in STA column will disappear 7 9 Exit OSD lt ESC gt Press lt ESC gt to exit OSD and to return to the selected computer A banner with the channel name will be shown on left upper corner of the screen 40 8 System Security 8 1 Lock the system There are three ways to lock the system In OSD mode press lt F3 gt Logout E Outside the OSD mode press lt Hot Key gt lt Hot Key gt H lt Enter gt to lock the system E Outside the OSD mode plug in a registered security dongle to lock the system 8 2 Unlock the system The unlock procedure depends on the security mode If the system is unlocked the name of login user will be displayed on the screen Figure 23 8 2 1 PSWD Dongle m Password verification Press any key in protect mode the login window will be shown on screen please enter user s name and password to pass the verification 1 z Fii adimi ri Figure 24 NW Security dongle verification Plug in the regis
15. evision reception if not installed and used properly This has been tested and found to comply with the limits of a Class B computing device in accordance with the specifications in Part 15 of the FCC Rules These specifications are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radio or television reception which can be determined by plugging the device in and out the user can try to correct the interference by one or more of the following measures O Reorient or relocate the receiving antenna 0 Increase the separation between the device and receiver Connect the computer into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help E 45
16. f keyboard NE Menu driven OSD On Screen Display Supports Auto Scan function to switch video inputs automatically among computers in preset intervals sequentially by OSD menu driven Supports LED display for PC and or server status monitoring Supports Beeper during Switching enabled KVM firmware is upgradeable via on board mini USB download connector and external mini programmer 1 3 Package Contents Dual Single Rail LCD Console drawer x 1 8 Port or 16 Port Combo Free KVM Switch x 1 Custom KVM Cables Set x 1 USB Security Key Dongle x 2 Optional Power Cord x 1 User s Manual x 1 Rack Mount Kit x 2 Se ee Oy O 2 Specifications 2 1 General 17 19 4CCFL LCD Panel SXGA Resolution up to 1024 x1280 75Hz 17 19 LCD Display Pixel pitch 0 264 H x0 264 V 0 294 H x0 294 V 6 language OSD Modules da English Chinese French Japanese Spanish German Backlight lifetime 50 000 hrs CD display automatically shut off at display angle under 30 degrees 105 key Keyboard supports Windows function keys compatible with IBM PC AT PS 2 keyboard 6 Language Keyboard type Germany English French Italian Spanish Chinese option Keyboard Touch Pad Module 1000 points inch 40 points mm graphics tablet mode Interface PS 2 compatible with Microsoft mouse driver Conirol center Combo free design S compatible with PS 2 amp USB connector Module Security function administrated by USB dongle at the
17. fic channel selection You can select the connected computers by using the two step Hot Key sequence Press lt Scroll Lock gt key twice Step 1 then press key 1 to 16 and lt Enter gt step 2 to select the computer you want to control 23 Figure 7 Specific channel selection hot key lt Scroll Lock gt lt Scroll Lock gt lt 1 gt lt Enter gt or lt Scroll Lock gt lt Scroll Lock gt lt 2 gt lt Enter gt or lt Scroll Lock gt lt Scroll Lock gt lt 16 gt lt Enter gt Note You can also select computers in OSD menu Move the indicator bar to the chanel to switch by using lt arrow key gt lt Page Up gt or lt Page Down then press lt Enter gt to select the connected computer Please refer section 7 2 Channel Selection in OSD 6 3 2 Arrow Key Channel Shift Function Press lt Scroll Lock gt twice and press lt Left Arrow gt or lt Right Arrow gt key to shift left right one channel gt Switch to left one channel lt Scroll Lock gt lt Scroll Lock gt lt Left Arrow gt gt Switch to right one channel lt Scroll Lock gt lt Scroll Lock gt lt Right Arrow gt 6 3 3 lt ALT gt Channel Shift Function 1 Start lt ALT gt Channel shift Function lt ALT gt channel shift function default was off You can press Hot Key lt Scroll Lock gt twice lt ALT gt and then press lt Enter gt to turn on or turn off this function alternately 2 Shift the
18. he right bracket Take care to align the central hole since we have left some wiggle room when previously install the left and the right bracket so that it will allows the stopper bar to go through the central hole correctly Then tighten all 3 screws on the front brackets of the Left and the Right Rail Step 10 Installation is complete Firstly you have to remove LCD Handles to release the locks towards as photos shown EAT Then pull out amp slide also with lifting up the LCD Display to appropriate position Step 11 After finishing Step 10 then to pull out Keyboard Handle Holder module or LCD module as photo shown Aval Dual Rail Congratulation All steps in the installation procedure are well done right now 20 5 Modularized Components Replacement 5 1 LCD Panel Module Replacement Step 1 Turning loose 2 pcs of screws on each side and then pull to lift it out LCD Panel Module Screws 21 Step 3 Take a new LCD panel and make due downward alignment to the tray chassis so that it can easily be docked with the VGA connector When you have fit it into the chassis then try put the screws on both side of the panel and tighten them up The replacement is now complete ay J 7 y 5 2 Keyboard Module Replacement Step 1 Remove one screw on each side of the keyboard tray and then you can pry and pull up the keyboard module to reveal the underside of it KIB
19. is powered on and ready to select BLANK Indicating this computer is not connected or powered on Channel scan indicator Status STA S This channel is marked for auto scan if the scan mode is Select type BLANK Indicating this computer is not marked for auto scan Current active channel number Indicate current active channel number The channel of the currently selected computer is displayed in the right upper corner lf the active channel is in 2nd or 3rd cascade layer the display string is like XX YY ZZ For example 02 05 07 means the active channel is layer 1 channel 2 links to layer 2 channel 5 and layer 3 channel 7 is selected as active channel Cascade parent channel number Indicate the parent channel of this cascade layer The number at the left upper corner below KVM layer number shows the number of port for the upper layer i e 8 means link from channel 8 of upper KVM It s valid only for 2nd and 3rd cascade layer It will show blank for Ist layer since there is no parent channel 31 7 1 6 Page down up indicator This is for 16 port KVM only The information of port 1 8 are display in the first page and information of port 9 16 are display in the second page Since the port information is divide to two pages the page down up indicator can remind you to switch to alternative page by using lt page down gt and lt page up gt key Function Control Menu The detail of control functions will be described in
20. lt Scroll Lock gt twice then D2D5D7 and lt Enter gt D2 layer 1 channel 2 links to D5 layer 2 channel 5 links to D7 layer 3 channel 7 selected Note You can also select active channel of cascade chain in OSD menu Move the indicator bar to the chanel to switch by using lt arrow key gt 2I lt Page Up gt or lt Page Downs and then press lt Enter gt to switch to the target port Please refer section 7 2 2 Channel select to cascade port 6 5 Buzzer sound Disable Enable Press lt Scroll Lock gt twice then lt B gt and lt Enter gt The buzzer sound will be disabled enabled alternately The buzzer sound default setting is ON lt Scroll Lock gt lt Scroll Lock gt gt lt B gt lt Enter gt Note You can also enable disable buzzer sound by pressing lt F1 gt in OSD main menu Please refer section 7 3 6 Setup in OSD Sound Figure 8 Buzzer setup hot key 6 6 Auto Scan Function When you enable Auto Scan function by pressing lt Scroll Lock gt twice then lt S gt and lt Enter gt The KVM Switch will shift through all the ports and display them on the monitor The mouse and keyboard will be disabled under this mode This is necessary to prevent errors such as erratic movement and wrong characters to display when using the mouse or keyboard in accident 6 6 1 Start auto scan function lt Scroll Lock gt lt Scroll Lock gt lt S gt lt Enter gt The auto scan banner will be show
21. menu Please refer section 7 3 2 Setup in OSD Scan Time 7 5 Console Lock in OSD lt F3 gt If the security mode is enabled in OSD mode by pressing lt F5 gt in OSD mode please refer section 7 7 Security Setup in OSD You can logout to lock console by pressing lt F3 gt In OSD mode The Console Lock Banner will be shown on the screen Security Mode Protected Figure 18 Console Lock Banner The KVM will be locked until an authorized user login Name JERRY Password Figure 19 Unlock window Note You can also logout to lock console via hot key by using lt Scroll Lock gt lt Scroll Lock gt lt H gt lt Enter gt outside the OSD mode Please refer section 6 7 Console Lock Note If you forget the password the only way to permanently disable the security function is to key in a universal password to unlock KVM You need to key in this unlock password to release your device and KVM and then you can restart everything Please contact with your agency distributor to get the universal password 36 7 6 Channel rename lt F4 gt Select the channel to rename by using up down arrow key and press lt F4 gt in OSD main menu The channel rename window will be shown for setting up the channel name Press lt ENTER gt to save the renamed channel name or lt ESC gt to cancel Figure 20 Channel Rename window 7 7 Security Setup lt F5 gt 7 7 1 Security mode login Press lt F5 gt in OSD main
22. menu to enter security setup mode the administrator login is required before entering into the security mode Admin Password Figure 21 Security mode login window The default administrator account is User Name admin Password 123456 After login the security setup main window will be shown on the screen Please select the security item to setup via lt up arrow gt and lt down arrow gt key and press lt left arrow gt or lt right arrow gt key to change the settings 37 Security Mode Admin Password lise 3 WEE BCID EF Ch Name Oi File Server fi ey D2 Mail Server Kei 03 Web Serveri WE O4 RD Switch W V Figure 22 Security setup main window 7 7 2 Security Mode 7 1 3 To change the security mode setting please move the highlight bar to Security Mode and press lt left arrow gt or lt right arrow gt key to change it The lt F3 gt Console Lock lt F6 gt Port Lock and user authority functions can not be executed until the security mode is enabled Change administrator password To change the administrator password move the highlight bar to Admin password and press lt left arrow gt or lt right arrow gt key The administrator password setup window will be shown on the screen Input the new password twice and press lt ENTER gt to confirm or press lt ESC gt to exit 03 Web Serveri 04 RD Switch Figure 23 Administrator password setup window 38 7 7 4 Auth
23. n to indicate the scanning channel 28 Figure 9 Auto scan hot key SCAN 01 Channel 1 E E DN ____ Channel Name Channel Number EEE Indicate now is Scan Mode Figure 10 Auto scan Banner 6 6 2 Stop auto scan function Press any key on keyboard to STOP the auto scan function Press the push button on KVM front panel to select active port can stop the auto scan function too 6 6 3 Auto scan mode There are two auto scan modes please refer section 7 3 1 Setup in OSD Scan Mode to setup the auto scan mode gt Scan all working computers gt Scan all computers which are marked for auto scan 6 6 4 Auto scan time interval The auto scan time interval can be adjustable by pressing lt F1 gt in OSD main menu Please refer section 7 3 1 Setup in OSD Scan Time Note You can also start auto scan function by pressing lt F2 gt in OSD main menu Please refer section 7 4 Auto Scan in OSD 29 6 7 Console Lock 7 1 lf the security mode is enabled in OSD mode by pressing lt F5 gt in OSD mode you can lock console by pressing lt Scroll Lock gt twice and then lt H gt and lt Enter gt The KVM will be locked until an authorized user login lt Scroll Lock gt lt Scroll Lock gt gt lt H gt lt Enter gt To unlock console please press any key according to screen message then key in User Name and Password The KVM switch and console devices will be unlocked and
24. orized user setup 3 authorized users are admitted to manage the KVM switch To change the user name and password please move the highlight bar to the user for editing Press lt left arrow gt or lt right arrow gt key the user name and password setup window will be shown on the screen Please Input the new user s name and password twice then press lt ENTER gt to confirm or lt ESC gt to cancel E 04 RD Switch Figure 24 User name password setup window 7 7 5 User Authority setup You can setup the authority for each user Different user has different access right for each channel To change the access right of each channel for certain user please move the highlight bar to the channel and press lt A gt lt 1 gt lt 2 gt or lt 3 gt to setup the channel access right for all or certain user You don t have to setup the authority of administrator since the administrator has all channel access right Security Mode OFF Admin Password hallas a F F ae a ot L Ta MAB CMD EF Ch Name 01 File Server 02 Mail Server 03 Web Serveri MV D4 RD Switch Y yI Xx Pp Y j k gl L f Y LJ LF Figure 25 User authority setup window 39 7 8 Lock Port lt F6 gt 7 8 1 Lock Port Only administrator can lock port Please move the highlight bar to the channel to lock and press lt F6 gt to lock the selected channel A red L mark will be shown in STA column of locked port En Nah
25. random code Built in the approved power adaptor Auto Scan Interval Adjustable time setting by OSD menu driven PC Connectors yigeo 8 16 HDB 15 female KB MS PS 2 8 USB signal combined connector Operating systems Windows 98SE ME 2000 XP 2003 Vista Server supported Linux Mac OS9 OSX and Sun Microsystems Selection Method On Screen Display OSD Push Button and Hot Key PS 2 USB Keyboard Extra console USBA Type Female x 2 Keyboard Mouse Connector Computer VGA female x 1 integrated with PS 2 kybd amp mouse Power Supply Universal 100 240V AC 50 60 Hz 4A input Materials Heavy duty steel electroplated for chassis WXDXH 45x 70x 4 4 cm Dimensions N W 14 5 KGS G W 20 KGS 3 Connecting All in one Dual Rail LCD Console Drawer 3 1 Configuration Diagram of Connections 8 16 port KYM sever PUTO LCD Drawer Dual Slide with 8 16 port KVM Combo Free So lotic A a O hn USB amp PS 2 PC Link Extra USB Console upgradable Qe 3 2 Components 3 2 1 Front View 4 Keyboard Module Keyboard Operation 6 SlideRailx4 Dual Slide Rails in each side Ca Power Swith rn Turno 9 PowerLED indicates Power Status Security Status USB Ports x 2 K B Mouse Security SecuKey Plug in external K B Mouse and SecuKey 11 K B module Handle Holder Pull to Slide the K B module in or out 12 8S 16 port KVM Combo Free Connect with KVM and console 3 2 2 Front Console Connections
26. sign solution is for easy installation and maintenance With our leading USB technology know how the unique and patented USB encryption security key can readily be bundled to the Drawer as to allow you a stringent access control that only allows access to authorized user possessing the security dongle and correct password thus preventing unauthorized intrusion into your rack servers Integrated KVM module with 17 19 LCD monitor amp Keyboard touch pad module within 1U chassis Supports modular design for easy installation and maintenance Supports extra USB keyboard and mouse port via front end USB ports Complies with EIA RS 310C 19 Rack Mount standard Heavy Duty Electroplate Steel Supports USB Key security function Optional Supports VGA resolutions up to 2048 x 1536 Connect computers via PS 2 and or USB at will Supports Windows Linux Mac OS9 OSX Sun Microsystems OSD is intuitive menus driven for quick and efficient navigation Supports Daisy chain with 3 level cascades up to 3 levels control up to 16 256 4096 PCs 16 Port from a single console cascaded units don t need special configuration Emulates PS 2 or USB keyboard on each PC to allow your computers to boot normally without a keyboard error Supports hot pluggable All devices connected to the KVM can be added or removed at any time without shutting the unit down Supports 3 types of switching m Hardware Push Button mE Hot Keys on PS 2 and or USB o
27. ster KVM Switch 2 Second level Slave KVM Switch connecting to Master KVM Switch if any 3 Third level Slave KVM Switch connecting to second level Slave KVM Switch if any 4 All computers connecting to Master Slave KVM Switch After all KVM Switches are powerd by power adaptor trun on the computers e Initial Plug in Process Please plug in the Master KVM Switch first before turning on any other devices like montior or computers e Hot plug and Hot Swap Combo Free 8 port amp 16 port KVM switch support Hot plug and Hot swap function y E z AN As Ao Ee O O A A EA O E do Eo Eo die Eo oO Eo E O a alo SRS pls es ie o ces aa clam Ee o SE de oE a HERO E 71S AE os o O A a E 4 ae Bo e mR o gt mmo cm y legal gt E Figure 6 Cascade chaining 3 3 3 Firmware download connector The min USB female connector on the rear of KVM switch is for firmware upgrade function To update your KVM firmware please contact with your dealer 3 3 4 Operation You can control computers via 8 Port or 16 Port Combo Free KVM Switch by push button hot key and OSD 1 Push button operation Press the push button to select the PC and operate it 2 Hot Key operation Please refer section 6 Hot Key Operation 3 OSD operation Please refer section 7 OSD Operation 4 INSTALLATION Precaution 1 Please check the whole unit for any damaged or missing parts when you receive
28. tered security dongle directly 41 8 2 2 PSWD Dongle m Password verification first Press any key in protect mode the login window will be shown on screen please enter user s name and password If the first stage verification is passed plug in the registered dongle of this user to pass the second stage verification to unlock the system F E A E F E La Es e Sn ee a A Figure 25 NW Security dongle verification first Plug in the registered security dongle directly If the security dongle is identified the owner s name of this dongle will be displayed on the screen please enter the password of this user to unlock the system Figure 26 8 3 Reset the administrator security lock lf the security mode is setup as PSWD DONGLE in case the administrator lost his security dongle or forget his password then the system settings can not be changed since administrator can not login to the system To solve this problem administrator must reset administrator security lock To reset administrator security lock you must contact your dealer and you must have either administrator password or dongle ready at hand If you lost both of them then there is no way to reset the administrator s lock you must return your machine to dealer for system reset and all data will be erased beyond recovery 42 The procedure to reset administrator security lock is e In protect mode press lt Hot Key gt lt Hot Key gt lt X gt
29. uters through PS 2 and or USB connection from one console PS 2 4 USB Mouse PS 2 amp USB Keyboard and Monitor The Console drawer similar to the front end Console module provides flicker free color images at optimal resolutions and has an ergonomically designed operation functionalities to maximize user convenience Installation setup can easily be done by a single person Simply use the Combo VGA cable of KVM switch set to link to the console ports no matter whether your connected port interface is either USB or PS 2 On Board monitor button allows straightforward connector selection LED lamps can perfectly show the situation of every single connector and support user to handle or operate the whole system On Screen Display OSD Menu allows straightforward display adjustments For even more convenience there are two additional external USB ports for front end connections with an extra set of USB keyboard and mouse in addition to the original built in keyboard touch pad set Further we are also providing modular design for LCD monitor and keyboard touch pad set to enhance convenience to help in case when one of them happens to be out of order then new replacement could be implemented immediately without further ado 1 2 Features The All in one LCD Drawer Dual Slide with 8 16 port KVM Combo Free features an integrated 17 inch 19 inch LCD panel module and keyboard touch pad module within an 1U chassis The unique modular de

Download Pdf Manuals