Thank you for purchasing the Wireless Water and Freeze

image

Contents

1. periodic Network Wide Inclusion Mode NWI automatically entered at power up if not in a network 2 Fast Blinks After Inclusion or at power up if already in a network 4 Fast Blinks periodic After exiting NWI mode and SSAS is not in a network or after exclusion 2 Slow Blinks periodic Main power dropout SSA3 is running on 9V a UO eeeees L Can mz C TEAL IU Ic 020 R34 R33 a HIN IMAG 7Y 02612 Cll UUU BOOL Contains IC 8156A 23US Contains FCG ID xe r 23Us SSA O3P2 Fortrez2Z2 LLC DIO 95 F20pQ93 BUE Rdl p30 Dl uuu tOr trezzZ com DC IN IN OUT t2483 481 7092 1 2 SPK GND BAT GND 124 TRIG GND Tanp TSW GND C Main Power Dropout optional 9V batter If main power drops the SSA3 can continue to operate on the internal 9V battery if installed but if triggered will only sound the Siren for approx 5 seconds and flash the Strobe for 30 seconds Also two seconds after power drops the SSA3 will sound the siren for 5 seconds and strobe the LEDs for 30 seconds if a 9V battery is installed Power dropout status can be monitored by a controller using the Alarm Command Class Version 2 The controller must enable power dropout monitoring in the SSA3 by using the Alarm Set command If the 9V backup battery is not discharged the SSA3 will send an alert to that controller at regular intervals when it detects that main power has dropped out In addition the status LED will periodically blin
2. the claims If you are not comfortable with your limited warranty or not completely satisfied with the SSA or the SSA3 does not perform as expected we encourage you to return the SSA3 to your DISTRIBUTOR for an exchange or for a full refund within 30 days of purchase Or you can return the SSA3 to FORTREZZ with an RGA number All products to be returned to FORTREZZ LLC must have a valid Returned Goods Authorization RGA Send the returned unit to FortrezZ LLC Warranty Replacement 1080 Centre Rd Suite C Auburn Hills MI 48326 return postage prepaid You must use the original packaging and include a proof of purchase photocopy of receipt along with the RGA 1080 Centre Rd Suite C Phone 248 481 7092 Auburn Hills MI 48326 sales fortrezz com FORTREZ Z www fortrezz com Made in USA 23Feb2013 P2
3. then immediately off when the window is opened and then quickly closed Application Status Command Class Responds with Application Busy Try Again in Waittime seconds if a delay is Configured and if Basic Set is used to try to turn off the SSA3 before the delay time has expired Waittime is number of remaining seconds in delay Multilevel Switch Start and Stop Level Change Commands are implemented levels change at 10sec intervals Alarm Command Class Ver 2 Signals that the main power has dropped out or has been applied if a 9V battery is installed Z Wave Alarm Type Power Management Alarm 0x08 Note that the SSA3 returns an Alarm Type Supported Report with a BitMask1 value of 0x80 Z Wave Alarm Events Voltage Drop Drift 0x05 Power Applied 0x01 only sent after Voltage Drop Drift event Z Wave Alarm Status OxFF Enabled Factory Default State 0x00 Disabled Note The SSA3 will only send the Alarm Report command unsolicited if it has previously received the Alarm Set Command In this case the report will be sent to the last node from which it received the Alarm Set Command i e it will not be broadcast to the Z Wave network 1080 Centre Rd Suite C Phone 248 481 7092 Auburn Hills MI 48326 sales fortrezz com FORTREZ Z www fortrezz com Made in USA 23Feb2013 P2 Status LED Indications lf the LED remains on after connecting power please disconnect and contact FortrezZ LLC customer service 1 Fast Blink
4. 5 is received by the SSA3 the unit will sound a 117 decibel audible alarm and will flash the strobe lights A value of 1 to 33 will turn on only the strobe lights while a value of 34 to 66 will turn on only the siren The same messages with value O will turn off both the siren and strobe lights Or the SSA3 can be turned off locally by quickly pressing the button three 3 times The SSA3 only returns 0 33 66 or 99 in response to a Multilevel Switch Get or Basic Get command depending on the mode With a controller the status of any SSA3 in the network can be checked A gateway controller s remote access capabilities may allow you to control or to check the status of any SSA3 in your network from a remote location such as from another city state or country Other Z Wave Information Generic Device Class GENERIC TYPE SWITCH MULTILEVEL Specific Device Class SPECIFIC_TYPE_NOT USED Manufacturer Specific Command Class Manufacturer ID 0x0084 Product Type ID 0x0313 Product ID Version and Revision may vary Version Command Class Provides Z Wave and application version information Configuration Command Class Parameter 1 Delay from the time the siren strobe turns on before the Basic Set Off command is accepted 1 Byte in seconds default is 0 interoreted as unsigned integer for negative values sent in set command This could be used for example to avoid the situation where an associated window sensor turns the SSA3 alarm on and
5. SA3 s bottom side to its permanent location j connect the 9V battery close the SSA3 and plug in the power adapter A Oe eS oOwwroandao N Inclusion in adding to a network 1 Set up the inclusion mode at the controller If the controller supports NWI the SSA8 will automatically be included at power on 2 If the controller does not support NWI press the SW1 button once to exit NWI mode 3 Press the SW1 button again to include the unit in the network The controller will indicate that the unit has been included in the network Also the Status LED will flash when the inclusion completes Inclusion and exclusion are always done at normal transmit power mode Exclusion from removing from a network 1 Set up the exclusion mode at the controller 2 Press the SW1 button once The SSA3 will be removed from the network and the Status LED will flash Associations Once in a network a controller can be used to associate other devices in the Z Wave network so they can control the SSA3 Refer to your controller s documentation on how to associate another device with the SSA3 Devices performing other functions and from other vendors can also be part of your network and can act as repeaters to extend the network range Go to www fortrezz com for controller examples Controlling the SSA3 MultiLevel Switch Command Class or Basic Command Class If a Z Wave MultiLevel Switch Set or Basic Set signal with a value of 67 to 99 or 25
6. Siren amp Strobe Alarm SSA3 User Manual ee Thank you for purchasing the SSA3 Indoor Outdoor wire and wireless Siren Strobe alarm This product will provide you with the peace of mind and protection you expect The SSA is a combination wired and wireless Siren amp Strobe Alarm It works with a traditional wire trigger from a security control panel or as a wireless Z Wave enabled alarm device and will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z Wave enabled network The SSA3 unit WILL ALERT you based on triggers from the home security panel only if correctly wired to the panel Also the SSA3 unit WILL ALERT you if it is included in and commanded from a Z Wave network The SSA3 unit can be used wired or wireless or BOTH at the same time For outdoor Use Unit is not recommended to be used in direct exposure to harsh elements rain snow and sun The SSA3 is based on wireless RF transmissions Any wireless transmission can be subject to RF interference and although unlikely this interference may cause the SSA3 to not operate as intended RF transmissions will be attenuated by tinted glass in wall isolation with metal foils metal objects etc Test communication to the SSA3 before final placement Add additional Z Wave repeater modules to improve RF communication if necessary Z Wave is a mesh network more units the better is the communication The SSA3 must not be used in li
7. e SSA3 needs to be triggered from the Security Panel connect wires to terminal block JP5 terminals labeled GND and TRIG Trigger from the Security Panel should go to GND If the STROBE function is necessary for alarms from Security Panel connect a solder bridge on R25 Jumper Note that connecting R25 Jumper will disable the Multilevel Function of the SSA3 in Z Wave mode of operation Using the SSA3 in a Z Wave Network The button inside the unit SW1 is used for including or excluding the SSA3 in a Z Wave network Refer to your controller s User Manual for details on network inclusion exclusion and association DA 565 1080 Centre Rd Suite C Phone 248 481 7092 a Auburn Hills MI 48326 sales fortrezz com FORTREZ www fortrezz com Made in USA 23Feb2013 Installation Follow this suggested sequence for testing and installation depress the tamper switch lever located on the back of the SSA3 and plug in the power adapter release the tamper switch and the SSA will alarm unplug the power adapter open the SSA3 unscrewing the screw on the front hold the tamper switch and plug it in include the SSA3 in the network by pressing and then releasing the button on the circuit board after the SSA3 has been included in your network and it communicates with the controller scenes rules associations may be set up h check the SSA3 through the controller for example set an alarm i unplug the power adapter and mount the S
8. encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CAUTION To satisfy FOC RF Exposure requirements for mobile and base station transmission devices a separation distance of 20cm or more should be maintained between the antenna of this device and persons during operation To ensure compliance operation at closer than this distance is not recommended 1080 Centre Rd Suite C Phone 248 481 7092 a Auburn Hills MI 48326 sales fortrezz com FORTREZ www fortrezz com Made in USA 23Feb2013 P2 Canada Industry Canada Statement per Section 4 0 of RSP 100 The term IC before the certification registration number only signifies that the Industry Canada technical specifications were met From section 7 1 5 of RSS GEN Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation From section 7 1 1 RSS Gen Issue 2 June 2007 a The host device as a stand alone unit without any separately certified modules complies with all applicable Radio Standards Specifications b The
9. f the product in a responsible manner LIMITED WARRANTY THE PRODUCT IS PROVIDED WITH ONE YEAR LIMITED MANUFACTURER WARRANTY FORTREZZ LLC warrants its products to be free from defects in material and workmanship under normal use for one year and is not responsible for consequential damages or installation costs of any nature FORTREZZ LLC expressly disclaims all implied warranties including but not limited to the implied warranties of merchantability and fitness for a particular purpose FORTREZZ LLC does not warrant guarantee or make any representations regarding the use or the results of the use of the products or any accompanying materials in terms of their correctness accuracy reliability or otherwise In no event shall FORTREZZ LLC be liable to Purchaser hereunder or in respect of any products ordered or delivered to Purchaser whether in contract tort including negligence or otherwise for a loss of profits or loss of use or for any incidental consequential special or indirect damages howsoever caused whether or not FORTREZZ LLC has been advised of the possibility of such loss or damage FORTREZZ LLC s maximum liability to Purchaser under these conditions shall in no event exceed the amount paid by Purchaser for the products that are the subject of the claim and in respect of all claims for products ordered from FORTREZZ LLC to which these conditions apply to the amount paid by Purchaser for the products which are the subject of
10. fe support and or safety applications Information provided in this document is for your convenience and may be superseded by updates to either the document or the product It is your responsibility to ensure that the SSA3 meets with your specifications Specifications Power DC Power adapter 9V to 16V 300mA or wire from Security Panel Distance Range Max 100ft line of sight in unobstructed environment Product Size LxWxD Approx 200mm x 10mm x 60mm height Product Weight 500g 1 Ib total weight including power adapter Operating Temperature 10 C 14F to 70 C 158F Sound Intensity 120dB 10cm 105dB 1m Anti tamper switch included System Requirement Any Z Wave enabled network and controller The SSA3 is extremely loud Wear ear Protection Be careful when power permanent or 9V backup is applied Testing the SSA3 prior to installation After connecting power to the SSA3 test the alarm mode after manually exiting the Network Wide Inclusion NWI mode Exit NWI mode by pressing the button once or after the unit is included into any Z Wave enabled network To then test the SSA3 press and hold the button The SSA3 will turn on and remain on until the button is released While the siren is on it will continually cycle for 4 seconds ON 1 second OFF for up to 5 minutes or until it is turned off While the strobe is on the unit will flash at a rate of once per second Hard Wire Installation Instructions If th
11. host device and all the separately certified modules it contains jointly meet the RF exposure compliance requirements of RSS 102 if applicable c The host device complies with the certification labeling requirements of each of the modules it contains From section 5 2 RSS Gen Issue 2 June 2007 Equipment Labels Contains IC 8156A Z3X From section 7 1 6 RSS Gen Issue 2 June 2007 Digital Circuits If the device contains digital circuitry that is not directly associated with the radio transmitter the device shall also have to comply with ICES 003 Class A or B as appropriate except for ICEC 003 labeling requirements The test data obtained for the ICES 003 tests shall be kept by the manufacturer or importer whose name appears on the equipment label and made available to Industry Canada on request for as long as the model is being marketed in Canada Europe The SSA3 module has been certified for use in European countries Completed testing Test standard ETSI EN 300 328 V1 7 1 2006 10 The Waste Electrical and Electronic Equipment WEEE directive 2002 96 EC was approved by the European Parliament and the Council of the European Union in 2003 This symbol indicates that this product contains electrical and electronic equipment that may include batteries printed circuit boards liquid crystal displays or other components that may be subject to local disposal regulations at your location Please understand those regulations and dispose o
12. k Under power dropout conditions if the SSA3 s periodic alerts are not being received this might be an indication that the backup battery has discharged or that transmissions from the SSA3 can no longer be routed perhaps because of power off to the entire house The 9V backup battery should be replaced once per year or more often if main power drops out Do not install batteries that appear damaged or unsealed FCC Compliance Statement Statements Contains Transmitter Module FCC ID XCT Z3US This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generate uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is