Home

i-Track User Guide.

image

Contents

1. BACK buttons together until it appears Should you have any queries or customer services issues please refer to the FAQ s section of our website www i trackoil com Product manual available online i Track Networks Ltd The Innovation Center Northern Ireland Science Park Queens Road Belfast BT3 9DT
2. FILL or LoSS will then appear in a log as either 01 or L 01 respectively along with the date of when it occurred Note Press the arrow buttons to view previous fills or losses and the dates in which they occurred By pressing the ENTER button at any of these logs you will be directed to a cost screen and a litres screen which calculates the volume of fuel which has been added or lost in that particular EVENT To update the cost of fuel press and hold the ENTER button on the cost screen until it begins to flash Use the arrow buttons to update the latest fuel costs Press ENTER again to accept the changes made Reseting the device 71000 amp iT9000 In order to make extreme changes to the date or alter the tank shape height or volume you must reset the device This can be achieved by completing the following simple steps 4 Press and hold the BACK button 2 Press and hold the DOWN arrow button 3 Press and hold the UP arrow button 4 Press and hold the ENTER button 5 The bar chart on the right hand side will begin to countdown 6 Once completed the screen will flash 7 Reset has been completed Once reset press any button to take you to the time and date screen to begin setup again Resetting this device will lose any previously logged data i e Fills or Losses 000o iTrack Introduction Thank you for selecting i Track as your intelligent monitoring system Keeping an eye on your o
3. are subject to change without notice The contents of this user manual may not be reproduced without the permission of the manufacturer Images shown in this manual may appear different to that of the actual product or display Nomenclature uSnd The uSnd notification signals that the ultrasound was unable to take a successful reading for the last 30 minutes or since the remote unit was powered up While the notification is active the base will continue to report the last good reading but will show that it is uncertain by the flashing segment in the bar graph rEnt Or REMOTE notification This signals that the base has not spoken to the remote unit in the last 4 hours or since the base unit has been powered up After the remote has been missing for just an hour the base will enter a scanning mode on its own indicated by the green LED flashing for just over 30 minutes to try and recover the unit It enters scanning mode again after an hour then after 2 4 and 8 hours and continues to scan every 8 hours until it recovers the unit Low Battery If the battery in the base is low the battery icon will flash on the display on all screens except the Remote Diagnostics rBAt tIME Lo FuLL FiLL LoSs Easy step by step user guide If the battery in the remote unit is low the rBAt notification will flash on the screen and the battery icon will flash on the Remote Diagnostics screen At extre
4. d the front window is made of glass and may break if the unit is dropped or impacted directly onto Keep the product away from direct heat sources such as radiators stoves heaters fires etc Do not tamper with any of the internal components as it will invalidate your warranty Do not attempt to repair the product yourself Contact a retailer or our customer service department Take care when handling all battery types Batteries can cause injury burns or damage to property if they come into contact with conducting materials Remove the batteries before storing for a long period of time Dispose of batteries correctly in accordance to local waste regulations When disposing the product do so in accordance with your local waste disposal regulations The Intelligent Oi Monitoring System Cleaning and Caring for the Product To ensure that you receive the maximum out of your product please observe the following instructions Display unit remove batteries before cleaning and clean using a damp cloth water Do not use any cleaning agents aerosols or liquids Outdoor unit wipe down using a damp cloth water Do not scratch hard or abrasive objects against the display unit as this may cause damage Do not leave discharged batteries in either of the units for any length of time as they may leak and cause corrosion Note The technical specification for this product and the contents of the user manual
5. different rates press the ENTER and BACK buttons a Cost C Percentage eGo d kgco Remote Diagnostic screen iT1000 amp iT9000 Time elapsed since last received a reading in minutes e g r0 05 indicates that 5 minutes has passed since it last received a message from the transmitter Fuel storage temperature where the i Track Transmitter is located in C Live distance MILLIMETERS between the i Track Transmitter and the fuel level Bar chart signifies reception strength between the units 10 increments To gain access to the remote diagnostic screen hold the BACK button which will bring you to the current default screen Depending on how many days of fuel there is remaining 7 Once at default screen hold the ENTER button in and the remote diagnostic screen will appear until the button is released To have the remote diagnostic screen remain on the display 4 Press and hold the ENTER button 2 Press and hold either of the arrow buttons 3 Release the ENTER button 4 Release the arrow button 5 Remote diagnostic screen will remain on the display 6 Press ENTER or BACK to dismiss Fill Events screen iT1000 amp iT9000 When a Fill or Loss occurs the words FiLL or LoSS will appear on screen along with the FILL segment being highlighted and a BEEP To accept press and hold the ENTER amp BACK buttons together until the word CLr appears then release The latest
6. il consumption has never been easier with the help of the new i Track wireless oil monitoring system This device will help to show the end user just how much oil they use waste in their homes and highlight the money they can save as a result i Track monitors the volume of fuel in tanks and for the FIRST time gives an accurate measurement of the average usage By adjusting the thermostat and turning radiators up and down in certain areas of the home i Track lets consumers know if they have made a difference to the amount of oil they have consumed and how much it has SAVED them It will also let them know how much harmful CO2 emissions the home is producing By having this device the user can save money by monitoring the changes they make to their home when adjustments are made to the thermostat Safety Guidelines To ensure that you use your product safely and correctly please read the Warnings amp Safety Precautions Caring for our Product and the User Guide sections before using this i Track oil measuring system Please observe the following warning and safety precaution guidelines when setting up and using this product When installing this system if in doubt always contact a qualified plumbing and heating engineer Do not immerse the display unit in water or other liquids If liquid is spilt over it dry it immediately Do not subject either of the units to excessive force or shock The LCD panel behin
7. me temperatures below 10 C the lithium battery in the remote unit must work harder in order to deliver the power required to operate the device properly As the battery ages this may cause the device to report a low voltage condition earlier than it would under moderate temperatures The tiME notification indicates that the correct time cannot be recovered Normally if the base resets when it comes back online it will recover the time from the remote unit when it next communicates this may take up to an hour to occur If the remote unit has also reset during this period it will not be possible to recover the time and after the base has communicated with the remote and discovered this fact it will present this notification When the Litres Percentage remaining and Days to Empty screen show Lo it indicates that there is less than 5 days of fuel remaining E indicates when the system believes that the tank is empty If the fuel is closer than 150mm to the remote unit then the percentage and volume screens will just show FuLL This indicates that the fuel level in the tank has increased rapidly and a Fill has occurred You can accept this through entering the Events Screen by pressing the ENTER amp BACK buttons together until it appears This indicates that the fuel level in your tank has dropped rapidly and a Loss has occurred You can accept this through entering the Events Screen by pressing the ENTER amp
8. that the system believes that the tank is empty Lo indicates that there is less than 5 days of fuel remaining FULL indicates that the fuel level is less than 150mm from the i Track Transmitter at the top of the tank Percentage Remaining screen iT1000 iT9000 24 hour clock Temperature at the indoor unit in C a Percentage of fuel remaining to 2 decimal places F Ss Fuel remaining bar chart 10 gt Ss increments 3 3 ao ROMO E indicates that the system believes that the tank is empty Lo indicates that there is less than 5 days of fuel remaining FULL indicates that the fuel level is less than 150mm from the i Track Transmitter at the top of the tank S 6 Ns Days to Empty screen T1000 amp iT9000 24 hour clock Temperature at the indoor unit in C No Days of fuel remaining in the tank Fuel remaining bar chart 10 increments Note E indicates that the system believes that the tank is empty Lo indicates that there is less than 5 ii days of fuel remaining When the system calculates there is less than 14 days of fuel remaining this becomes the DEFAULT screen rack i Bo oo of Consumption Rate 79000 only There are four different types of consumption calculated COST LITRES PERCENTAGE amp CO2 EMISSIONS These are displayed in a Daily Weekly Monthly and Annual rate To alternate between the
9. z N iTrack The Intelligent Oi Monitoring System Use the up and down arrows to navigate through the user screens At any stage hold the back button to return to the default screen The default screens Litres Remaining more than 14 days of fuel remaining Days to Empty less than 14 days of fuel remaining When the system calculates this it will then change to the Days to Empty Screen for 2 seconds out of every 20 seconds and beep when this change occurs Pressing simultaneously the ENTER and BACK buttons will disable the beeping until the next midday or another Fill or Loss has occurred Easy step by step user guide 3 2 1 Time and Date screen iT1000 amp iT9000 Date Day Month and Year lt lt 24 hour clock Fuel remaining bar chart 10 increments Note To change the time or date hold the ENTER button while on the time date screen until it begins to flash Then using the arrow buttons scroll to the correct time To change the date continue to hold the arrow button longer and as it speeds up it will also change through the dates After initial setup the date can only be brought forward 14 days amp back 1 day without resetting the device Litres Remaining screen iT1000 amp iT9000 24 hour clock Temperature at the indoor unit in C E Number of litres remaining Fuel remaining bar chart 10 increments DEFAULT screen Note E indicates