1. Yellow When external power supplied to the unit from AC power source or DC cord the power light will be illuminated as green When internal power supplied to the unit from an internal rechargeable battery the power light will be illuminated as yellow AC OPERATION Plug the small connector of the AC adapter into the DC power input located on the side of the unit Plug the AC end into a grounded wall outlet power source NOTE The power supply may become warm to the touch during charging or running of the unit This is normal 12V DC OPERATION Plug the small connector of the DC power cord into the DC power input on the side of the unit set up amp operation o BATTERY OPERATION To ensure proper operation from internal battery fully charge the battery for 1 5 hours as explained in the Battery Charging section To operate the unit from an internal rechargeable battery ensure that no external power sources are plugged into the DC power input on the side of the unit Once the power source is selected simply turn the unit on using the power switch located on the side of the unit The power indicator light displayed on the front of the unit will glow yellow to show which power source is being used and glow green when an external power is connected battery charging IMPORTANT OPERATION AND BATTERY INSTRUCTIONS Your 18605 portable suction machine is capable to run on AC or DC power To ensure full func tion of this unit the bat
2. instructed by a physician or other qualified health care professional introduction Features New anti bacteria filter design helps prevent contamination High quality vacuum regulator and anti vibration vacuum gauge setting eo Oil less permanent lubrication e Collection bottle with overflow protection o Superior performance and high reliability for continuous operation design o Easy carry and easy cleaning Following the recommended operating and maintenance procedures outlined in this user s manual will maximize the life of this product Refer to the diagrams on page 6 ZN NOTE This unit complies with electromagnetic compatibility standards as defined in the attached declaration of conformity illustration of important parts Item 18605 Bacteria filter non sterile 4 Connection tubing Vacuum gauge Tubing connector Vacuum regulator knob DC power input on side Power switch 6 patient tubing 800cc disposable canister w lid float shut off incorporated into lid 10 90 connection elbow OPN OOKRWN set up amp operation o IMPORTANT OPERATION AND BATTERY INSTRUCTIONS Your 18605 portable suction machine is capable to run on AC or DC power To ensure full func tion of this unit the battery must be completely charged before the first use Do not turn on the unit before the battery is completely charged It takes approximately 1 5 hours to fully charge the unit Charge the unit whe
3. to be free from defective workmanship and materials for a period of two years from date of purchase Internal rechargeable batteries are warranted for 90 days Any defective part s will be repaired or replaced at Drive Medical s option if the unit has not been tampered with or used improperly during that period Make certain that any malfunction is not due to inadequate cleaning or failure to follow the instructions If repair is necessary contact your Drive Medical Provider or Drive Medical Service Department for instructions NOTE This warranty does not cover providing a loaner unit compensating for costs incurred in rental while said unit is under repair or costs for labor incurred in repairing or replacing defective part s THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DU RATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE LIMITATION OR EXCLUSION OF CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU This warranty gives you specific legal rights and you may also have other righ
4. 70 kPA 15 4 Psi 106 kPA Storage Transport Temperature Range 40 F 40 C 158 F 70 C Storage amp Transport Relative Humidity 0 95 Storage amp Transport Atmospheric Pressure 7 3 Psi 50 kPA 15 4 Psi 106 kPA WARRANTY 18605 SOH S era as Two years limited excluding internal battery Internal Dale viviana RA 90 day specifications classification APPROVALS 19605 JONES ansias IEC 601 1 CAN CSA C22 2 No 601 1 M90 UL 60601 1 IEC 60601 1 2 EQUIPMENT CLASSIFICATIONS With respect to protection from electric shock Class and internally powered Degree of protection against electric shock Type B Applied Parts Degree of protection against ingress of liquids IPXO and ordinary power supply Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air or nitrous oxide ISO Classification 18605 Series only Electrically powered medical suction equipment for field and transport use according to ISO 10079 1 1999 High Flow High Vacuum 18605Series Electrically powered medical suction equipment for non transport use according to ISO 10079 1 1999 Drive Medical will make available on request circuit diagrams parts lists etc warranty TWO YEAR LIMITED WARRANTY The compressor portion of the Drive Suction Unit 18605 Series excluding internal rechargeable batteries is warranted
5. TION Discharging the battery completely will shorten the life of the battery Do not operate the unit more than a few minutes if the low battery indicator light is lit Recharge as soon as possible NOTE When charging the battery the battery charging indicator light will remain lit If your unit does not hold a charge please be sure the model you are using has a battery installed prior to return ing it to your authorized Drive Medical provider or to Drive Medical Verify that the charge light turns on when the external power is applied with the switch in the OFF position NOTE Units equipped with an internal rechargeable battery contain a lithium ion battery which must be recycled cleaning amp maintenance O Collection Bottle 1 Shut off unit using power switch and allow vacuum to drop Disconnect power source from the DC input receptacle on the unit 2 With the collection bottle still in the holder remove the lid The bottle can now be taken out of the holder to be emptied NOTE Collection bottle should be emptied and cleaned after each use The 800cc disposable collection bottle and lid are meant for single patient use 3 Collection bottles and lids should be thoroughly cleaned after each use by one of the following methods All Bottles Wash in a hot water dishwashing detergent solution and rinse with clean hot tap water Then wash in one part vinegar to three parts hot water solution Rinse with hot tap water and air d
6. USER S MANUAL REF 18605 www drivemedical com Rev1 06 02 14 index DONA Safety Information ses o ssoseseoeososeseoeoroseseosososeseosesese 2 4 AG Power SOBRES 3 E e e PAT N E E E A T 3 4 o A oaar 4 Illustration of Important Parts ococononoononononomsomomos 5 A E R 6 How to Operate Your Heavy Duty Suction Pump 6 7 Battery Charlie 7 8 Cleaning Instructions cenit tditiend 8 9 il AA An 9 10 Tous 10 Specifications Classifications cooommmmmm 11 12 La A O mercer tue erorremr rar rte A 12 13 AN CAUTION Federal law restricts this device to sale by or on order of a physician or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device NOTE Meck ALL parts for shipping damage If shipping damage is noted DO NOT use Contact medi cal equipment provider for further instruction Safety information o 1 SAFETY INFORMATION When using electrical products especially when children are present basic safety precautions should always be followed Read all instructions before using Important information is highlighted by these terms N DANGER Urgent safety information for hazards that will cause serious injury or death ZN WARNING Important safety information for hazards that might cause serious injury ZN CAUTION Information for preventing damage to the product ZN NOTE Information to which you should pay spe
7. cial attention read all user s manual before using save user s manual ZA DANGER To reduce the risk of electrocution 1 Do not use while bathing 2 Do not place or store product where it can fall or be pulled into a tub or sink 3 Do not place in or drop into water or other liquid 4 Do not reach for a product that has fallen into water Unplug immediately ZN WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this product is used by on or near children or invalids 2 Use this product only for its intended use as described in this guide 3 Never operate this product if a It has a damaged power cord or plug b It is not working properly c It has been dropped or damaged d It has been dropped into water 4 Keep the power cord away from heated surfaces 5 Never use while drowsy or asleep NOTE Item 18605 series is factory equipped with an internal rechargeable battery and all information regarding battery operation in this guide is applicable Safety information A SPECIFIC WARNINGS TO REDUCE THE RISK OF ELECTRICAL SHOCK OR INJURY TO PERSONS DO NOT DISASSEMBLE THIS UNIT DISASSEMBLY OR ATTEMPTED REPAIRS IF ACCOMPLISHED INCORRECTLY CAN CREATE ELECTRICAL SHOCK HAZARD ONLY QUALIFIED TECHNICIANS SHOULD PERFORM SERVICING OF THIS SUCTION UNIT Z DANGER The AC DC Portable Suction Pump is a vacuum suction device designed for the collection of nonflammabl
8. e fluid materials in medical applications only Improper use during medical applica tions can cause injury or death For all medical applications 1 All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority 2 Some attachments or accessories may not fit the tubing supplied All attachments or accesso ries should be checked prior to use to assure proper fit INTERNATIONAL TRAVEL Item 18605 is equipped with a switch mode power supply allowing operation on any AC voltage 100 240 VAC 50 60 Hz However the correct power cord must be used to connect to adaptable wall power INTRODUCTION Your Drive Suction Unit is a compact medical suctioning device which has been designed for reli able portable operation Because of the small size light weight and DC operation the Drive Suc tion Unit is ideal for providing suction in the home in transport with optional DC cord or if your model has an internal rechargeable battery the unit can be operated anywhere One 800cc canister bottle is the only choice Following the recommended operating and maintenance procedures outlined in this instruction guide will maximize the life of this product Safety information Z WARNING Proper operation of this product is necessary to avoid physical harm Improper use can cause personal injury and or tissue damage This product should not be used unless the operator has been
9. ents If service is required return unit to a qualified Drive Medical provider or an authorized service center Opening or tampering with the unit will void warranty Filter Changing 1 Change bacteria filter if overflow occurs or every two months whichever comes first 2 Remove filter by disconnecting it from suction unit and lid assembly 3 Replace with a clean Drive bacteria filter non sterile 10 pack and remount to suction unit and lid Additional filters may be purchased from your authorized Drive Medical provider NOTE Do not substitute any other material for this bacteria filter Substitution may lead to contamina tion or poor performance use only Drive filters TROUBLESHOOTING NOTE Your Drive Suction Unit contains no user serviceable parts If you believe your unit is not working properly BEFORE YOU RETURN IT TO THE HOME MEDICAL EQUIPMENT PROVIDER WHERE YOU PURCHASED IT OR TO Drive MEDICAL please take a few moments to check for these possible causes PROBLEM ACTION Unit does not turn on 1 Check power sources and connections Green external power indicator 2 Ensure wall outlet is live by plugging in a lamp should be illuminated when 3 If running from an internal battery ensure that your power is applied unit has a battery installed 4 If battery is installed check that it is fully charged Pump runs 1 Check that all tubing is connected properly but no vacuum 2 Check tubing connections for breaks or leak
10. n battery levels are low to ensure proper operation TUBING AND FILTER CONNECTIONS 1 Connect either end of the 4 tubing to the tubing connector then connect the other end to the bacteria filter Ensure that the clear side of the bacteria filter is toward elbow and bottle when installing re installing Do not reverse direction of filter 2 The bacteria filter should then be connected to the 90 elbow connection and the 90 con nection should be connected to the top of the canister lid where it says lt Vacuum 3 The 6 patient tubing should be connected to the canister lid at the outlet labeled lt Patient gt 4 Please assure that all connections are secure and without leaks before using 5 Verify that unit is at desired suction level before beginning patient suction 7 HOW TO OPERATE YOUR PORTABLE SUCTION PUMP Before connecting the unit to the AC adapter or 12V DC cord make sure that the power switch located on the side of the unit is in the OFF position Select power source desired LED EXPLANATIONS LOW BATTERY Red Seek another power source and charge battery as soon as possible when the red light remains flashing and audio alarm sounds CHARGING Yellow When the battery is being charged the yellow light on the front cover will be illuminated At the same time the red light on the AC adapter will be also illuminated When the battery is fully charged the red light on the AC adapter will turn to green POWER Green
11. ry Autoclave for 3 to 5 minute cycle at 270 F 132 C In lieu of autoclave sterilization the above parts can be soaked in an activated dialdehyde solution Z WARNING The waste in collection bottle may cause respiratory infection and must be handled according to medical waste disposing regulation Operator must wear gloves and medical class mask before cleaning the collection bottle tubing and handling the waste unit and or accessories Suction Unit 1 With the power switch in the OFF position disconnect the Drive Suction Unit from all exter nal power sources 2 Wipe the housing with a clean cloth and any commercial bacterial germicidal disinfectant CAUTION Do not submerge in water as this will result in damage to the vacuum pump Tubing 1 Disconnect the tubing from the unit 2 Tubing should be rinsed thoroughly after every use by running hot tap water through it fol lowed by a solution of one part vinegar to three parts hot water 3 Rinse with hot tap water and air dry 4 Keep the outer surface of the tubing clean by wiping with a clean damp cloth Carrying Case 1 Wipe the case using a clean cloth dampened with detergent and or disinfectant maintenance amp troubleshooting MAINTENANCE Inspect suction tubing and collection bottle for leaks cracks etc before each use DANGER Electric shock hazard Do not attempt to open or remove cabinet there are no user serviceable internal compon
12. s 3 Ensure that flow shut off is not activated 4 Check for leaks or cracks in bottle assembly Low vacuum 1 Use vacuum adjustment knob to increase vacuum level 2 Check system for leaks 3 Push vacuum adjustment knob and then release Battery will not hold a charge 1 Ensure that unit is equipped with an internal battery Charge indicator should be by contacting your Drive Medical equipment provider illuminated if battery is connected 2 Verify that charge light turns on during charge mode 3 Check electrical connections during charging 4 Ensure wall outlet is live by plugging in a lamp specifications classification Size H x W x D inches cm 0 ccc cece cee eee eee 14 2 x 7 0 x 8 0 36 x 17 8 x 20 3 Weight ID ales der 7 3 lbs 3 3 kg Electrical Requirements 0 ooocoocccococococcrooo oo 100 240 V AC 50 60 Hz 1 2 A max 12 V DC 36 W max Internal Rechargeable Battery oooooooo o Factory Equipped Vacuum Range 425s iweaetedok Kevedsciheceedsae ae O to 600 mmHg O to 60 cmHg Air Flow pump inlet ibero rn cl 20 LPM free flow typical may be less when running from internal battery Collection Bottle Capacity sois rd 800cc ml Disposable ENVIRONMENTAL CONDITIONS Operating Temperature Range ooooooooo 32 F 0 C 104 F 40 C Operating Relative Humidity oo oo 0 95 Operating Atmospheric Pressure oooooooooooo o 10 2 Psi
13. tery must be completely charged before the first use Do not turn on the unit before the battery is completely charged It takes approximately 1 5 hours to fully charge the unit Charge the unit when battery levels are low to ensure proper operation WARNING If the unit does not receive an external power source or the battery does not get recharged im mediately the low battery indicator light will remain on and the performance of the unit will drop off rapidly Switch to another power source immediately to avoid an interrupted suction procedure Adjust the vacuum level from 0 to 600 mmHg 0 to 60 cmHg by turning the vacuum regulator knob located on the side of the unit clockwise to increase vacuum and counter clockwise to de crease vacuum The desired level of vacuum can be set by using the gauge located on the front of the unit To accurately read the gauge block the patient end of the hose or cap off the collec tion bottle and allow the gauge to reach a stable vacuum reading NOTE Gauge is for reference only If the unit sustains a severe drop accuracy of the gauge must be checked Suction at the patient is automatically obstructed when liquid level reaches the float shut off located on the underside of the collection bottle lid NOTE Always transport unit with vacuum regulator knob rotated fully clockwise in case unit is dropped CAUTION When automatic float shut off is activated contents of the collection bottle should be emp
14. tied Further suctioning could cause damage to the vacuum pump CAUTION Should fluid be aspirated back into the unit equipment provider servicing is necessary as pos sible vacuum pump damage may result battery charging O BATTERY CHARGING On 18605 series the units are equipped with a factory installed rechargeable battery The unit will have a light for low battery and charge indication Once you ve determined that your unit is equipped with an internal rechargeable battery con nect the unit to the proper AC or DC power source using the AC adapter or DC power cord The yellow charge indicator will be illuminated while the battery is charging At the same time the red light on the AC adapter will be also illuminated Verify that this illuminates when charging begins As the battery is fully charged the red light on the AC adapter will turn to green NOTE A discharged battery will require a few hours depending on depth of discharge of charging to reach a full capacity NOTE Do not connect the AC adapter to an outlet controlled by a switch to ensure power is supplied to unit at all times NOTE Do not connect the DC power cord to an outlet that is not constantly energized NOTE A fully charged battery on the 18605 series will provide approximately 60 minutes of continuous operation at a zero vacuum level free flow NOTE If unit is not in use for extended periods battery should be recharged every 6 months minimum CAU
15. ts which vary from state to state Thank you for choosing a Drive Suction Unit We want you to be a satisfied customer If you have any questions or comments please send them to our address on the back cover For Service Call Your Authorized Drive Medical Provider Phone Purchase Date Serial warranty DECLARATION OF CONFORMITY Manufacturer Drive Medical Design amp Manufacturing 99 Seaview Boulevard Port Washington NY 11050 Product Designation Type Model 18605 We herewith declare that the above mentioned product complies with the requirements of EC Directive 93 42 EEC and the following Class lla Rule 2 Quality System Standards Applied ISO13485 Notified Body RWTUV MDD Annex II Applied Safety Standards Applied EN60601 1 2006 1EC60601 1 2005 CORR 1 2006 CORR 2 2007 CAN CSA 22 2 No 601 1 M90 UL 60601 1 2003 ISO 10079 1 1999 EMC Electromagnetic Compatibility Compliance to EN 60601 1 2 2007 All applicable stan dards available upon request drive Drive Medical Design amp Manufacturing 99 Seaview Boulevard Port Washington NY 11050 Tel 516 988 4600 Fax 516 998 4601 Rev1 06 02 14
Download Pdf Manuals
Related Search
Related Contents
M-Cab SATA Adapter HP 5150A User's Manual Online Users Manual Revised 03_10 テープを聞く 準備する SIO-232.CF User Manual Fitness & Probity Individual Questionnaire (IQ) Application Guidance Manual de Usuario AT8603B VR & VF Service Manual Rev03 13Dec01.qxd Vantec NST-D400S3-BK Manhattan 161107 loudspeaker Copyright © All rights reserved.