Home

SMART WINDOW AIR CONDITIONER

image

Contents

1. N 0 HN N N ee eee HN CCC CC N eee ee 0 0 0000 CC CC 0 6060000 For reference jot down the Serial Number here MODEL BOWAC8000 SERIAL Find this number on a
2. WT mnm nm 299952592995
3. FAN SPEED Quirky cool eco fan high medium low DO NOT OPERATE IN FREEZING OUTDOOR CONDITIONS This air conditioner was not designed for and should not be used in freezing outdoor conditions COOL MODE Use the Cool mode at Low Med or High for cooling Use the Temperature Increase Decrease controls to set the desired temperature between 64 F and 86 F in 1 F increments An electronic thermostat is used to maintain the room temperature The compressor will cycle on and off to keep the room at the set level of comfort Set the thermostat at a lower number and the indoor air will become cooler Set the thermostat at a higher number and the indoor air will become warmer NOTE If aros is off and is then turned on while set to a cool setting or if turned from a fan setting to a cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin COOLING DESCRIPTIONS For normal cooling Select the Cool mode and High or Med fan with a middle set temperature For maximum cooling Select the Cool mode and High fan with a lower set temperature For quieter and nighttime cooling Select the Cool mode and Low fan with a middle set temperature ECO MODE This mode optimizes the cooling power of your air conditioner thereby saving you energy Once the set point temperature has been reached the fan will cycle off to save energy The fan will cycle back on
4. Note to consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical skills Completion time Approximately 1 hour e We recommend that two people install this product e Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the warranty You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner TOOLS YOU WILL NEED aes flat blade screwdriver Phillips head screwdriver E OR pencil scissors or knife VITTILPLLLA 0 TE E 0 0 9 9 9 9 2 99 EE i 0 0 8 2 jm BS a Um EB ig ae AZA a a 9 a 9 9 9 9 9 9 9 e 9 999 ELECTRICAL REQUIREMENTS Aros requires a 115 120 volt AC 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug o
5. 6 PREPARE YOUR STANDARD DOUBLE HUNG WINDOW Cut the window sash seal to the proper length for your window Remove the seal s backing and adhere it to the underside of the window sash p 7 INSTALL THE AIR CONDITIONER IN THE WINDOW Place Aros on the sill with the bottom mounting rail against its back edge Pe 9999 9999 0000 999 9o 9 e eee ee e eec 9 e900 e acou oss M EREEREER e oo 0 00 09 00 000 Do TENE esoo 99909 9 t o e ee Center it and close the window securely behind the top mounting rail Aros should be level or slightly tilted outside Use a level about a 1 3 bubble will be the correct case slant to the outside INSTALL WINDOW LOCKING BRACKET AND FOAM TOP WINDOW GASKET CAUTION To prevent broken glass or damage to windows on vinyl or other similarly constructed windows attach the window locking bracket to the window side jamb with one type B screw a wood A Cut foam top window gasket to the window width then stuff it between the glass and the window B Stuff the foam between the glass and the window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your window obtain appropriate material locally to provide a proper installation seal
6. 0000 O O O o O o0 O 9 O0 9 O9 Oo Oo O o O o oe O O O O0 09 O0 9 O0 Oo O0 O0 Oo O0 Oo Oo O O6 oe O O O9 O0 O0 09 O0 Oo O Oo Oo o O O o O O O O O 0 O O0 O6 O6 O6 O6 O6 O0 O0 O6 O6 O6 O6 O6 6 O6 o eo O O9 09 09 O0 O0 O9 O0 O0 O0 O0 O0 O Oo Oo Oo 6 O6 eoe 0O 009 09090 9 509509095 0 0 O 0 0 O09 9 oe eo O O O 69 09 0 O O 9 9 9 9 9 9 9 eoe O eo 090060 90009 9 9 909 990 99 9090 80 O 6 O O 09 9 9 9 9 oe O o O O O O O O O0 O0 O6 O6 O6 e 9 9 9 9 9 9 9 9 9 9 9 e O eoe O 9 9 9 9 9 9 9 9 9 6 9 9 9 9 9 9 9 9 9 eoe A m A m AA m m m m m m m m m m m m mA mA m m A a m TROUBLESHOOTING TIPS PROBLEM POSSIBLE CAUSES AIR CONDITIONER Air conditioner DOES NOT START does not
7. label on the side of the air conditioner Complete owner s manual also at quirky com aros manual AROS 2 TABLE OF CONTENTS SAFETY INSTRUCTIONS OPERATING INSTRUCTIONS About smart technology About the controls on the air conditioner INSTALLATION INSTRUCTIONS TROUBLESHOOTING TIPS CARE AND CLEANING WARRANTY 12 13 14 SAFETY INSTRUCTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING FOR YOUR SAFETY THE INFORMATION IN THIS MANUAL MUST BE FOLLOWED TO MINIMIZE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY SAFETY PRECAUTIONS e Use this appliance only for its intended purpose as described in this owner s manual e This air conditioner must be properly installed in accordance with the installation instructions before it is used Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Replace immediately all electric service cords that have become frayed or otherwise damaged A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end Turn the unit OFF and unplug your air conditioner before you begin cleaning Quirky GE do not support any servicing of the air conditioner We strongly recommend that you do not attempt to
8. periodically to ensure all cooling capacity in the system is used This mode is the default mode for the unit Each time the unit is powered off it will restart in Eco mode ON The first time the unit is turned on the settings will be 70 and Low fan You can adjust the fan speed and temperature to your personal comfort Eco ON helps minimize electricity use It is normal for the fan to cycle off and then back on in this mode This on off cycle can repeat multiple times Because the fan will cycle off you may notice a variation in room temperature and humidity Eco OFF When this mode is not engaged the fan will run continuously and in Cool mode the compressor will cycle on and off to maintain room temperature FAN ONLY MODE Use the Fan only mode at Low Med or High fan speed to provide air circulation and filtering without cooling Since fan only settings do not provide cooling a set temperature cannot be entered The room temperature will appear in the display POWER OUTAGE RECOVERY FEATURE In the case of a power outage or interruption the unit will automatically restart in the settings last used after the power is restored AROS 5 INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY Important Save these instructions for local inspector s use Important Observe all governing codes and ordinances e Note to installer Be sure to leave these instructions with the consumer
9. service the air conditioner yourself For your safety do not store or use combustible materials gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance All air conditioners contain refrigerants which under federal law must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do e Ifthe receptacle does not match the plug the receptacle must be changed out by a qualified electrician This air conditioning system requires contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DONOT use equipment certified for R22 refrigerant only HOW TO CONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded DO NOT USE AN ADAPTER PLUG WITH THIS APPLIANCE The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of electric shock hazard from this appliance Power cord includes a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet If the TEST button does
10. 006 000 000 000 00 00 0909 oe 00 090 9009 09009 09009 0909009 090900 0009 000 0006 000 0009 000 00090 0009 000090 00 0000 0009 000 000 000 000 0009 000 000 09009 0009 0 0900 09009 90 00 oe o 00 90 09 90 09009 090 09 090 09 0909009 0900 000 09006 000 0900 0900 000 000 00000 009 09 09 0 09 0909009 09 0 9009 09009 09090 09 09090 0 ee 0009 000 000 000 0006 000 00 000 000 000 000 000 000 000 000 09009 09009 090 09009 09 090 09 0 0 0009090000900 00000 0000 oe 90 909 090 9009 090 09009 090 09009 0909009 0900 0900 000 000 000 000 000 000 00 0009009009000 000 000 000 000 000 000 000 000 09 00 09 09009 0 0 0909 0 9 0909009 9 09 09090 90 9 9 9 CC 9909000990909 on off mode fan Fo
11. AROS SMART WINDOW AIR CONDITIONER Part of the Quirky GE collection of smart products Aros is an app enabled air conditioning unit that reacts to its surroundings to save you Time Energy amp Money Quirky b b J oe oe er o C C 9 9 0 N
12. ONER Ice blocks the air flow and stops FREEZING UP the air conditioner from cooling the room WATER DRIPS OUTSIDE Hot humid weather WATER DRIPS INDOORS The air conditioner is not tilted to the outside WATER COLLECTS Moisture removed from air and IN BASE PAN drains into base pan CARE AND CLEANING GRILLE AND CASE Turn the air conditioner off and remove the plug from the wall outlet before cleaning To clean use water and a mild detergent Do not use bleach or abrasives OUTDOOR COILS The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned CAUTION DO NOT OPERATE THE AIR CONDITIONER WITHOUT A FILTER BECAUSE DIRT AND LINT WILL CLOG IT AND REDUCE PERFORMANCE WHAT TO DO Set the controls at HIGH FAN or HIGH COOL and set the thermostat to a higher temperature This is normal For proper water disposal make sure the air conditioner slants slightly away from the case front to the rear This is normal for a short period in areas with little humidity normal for a longer period in very humid areas AIR FILTER The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary To remove pull the tab on the right side of the unit until the filter is out Clean the filter with warm soapy water Rinse and let the filter dry before replacing it Do not clean t
13. f the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance Replacement of house fuses or resetting of circuit ee O9 9 9 O9 9 9 O O O O O O O O O O O O a O O Dad Eee Damage to the product caused by improper power supply voltage accident fire floods or acts of God on off mode fan WA WW cool high Incidental or consequential damage caused by possible defects with this air conditioner eco medium Damage caused after delivery fan low 5 E ade acide Y ae aS gt E VU ie uw s a dit ees LINE E ouk AROS 14 AROS 15 CUSTOMER SUPPORT For service and support email us at questions quirky com or call 1 866 5QUIRKY 1 866 578 4759 Complete owner s manual also at quirky com aros manual atte aaa aad es 6 0 ee n0 09 e 9 9 9 0 0 9 9 00 0 0 8 i
14. he filter in a dishwasher eaoee o oot vec e ge AROS 13 WARRANTY Quirky GE Aros Air Conditioner One Year Limited Warranty Staple your receipt here Proof of the original purchase date is needed to make a warranty claim FOR THE PERIOD OF One Year From the date of the original purchase WE WILL REPLACE Air conditioning unit for any product which fails due to a defect in materials or workmanship The replacement unit is warranted for the remainder of your product s original one year warranty period IN ORDER TO MAKE A WARRANTY CLAIM Contact customer service by calling 1 866 5QUIRKY 1 866 578 4759 WHAT S NOT COVERED e Customer instruction This owner s manual provides information regarding operating instructions and user o 9 9 9 O O O O O O O O6 O O O O O O6 O6 O6 O6 O6 O6 oO controls 0 09 9 9 9 9 0 0 0 0 0 09 9 0 9 0 0 9 0 09 9 9 e Improper installation delivery or maintenance lf you have an installation problem or if the air conditioner is of improper cooling capacity contact your dealer or installer You are responsible for providing adequate electrical plumbing and other connecting facilities A Failure o
15. me For more information download and launch the Wink app on your mobile device then follow its instructions to connect ABOUT THE CONTROLS ON THE AIR CONDITIONER Lights will illuminate next to each option when activated to indicate the selected settings e POWER Turns air conditioner on and off When turned on the display will show the room temperature Use to set the air conditioner to Cool Eco or Fan only mode e FAN SPEED Use to set the fan speed to High Med or Low on the unit o TEMPERATURE INCREASE DECREASE Use up and down arrows to set temperature when in Cool or Eco mode Shows the room temperature Shows the set temperature while setting the temperature in Cool or Eco modes NOTE The default temperature reading on the display is degree Fahrenheit F To change the display to degree Celsius C press Temperature Increase and Temperature Decrease at the same time and hold for 3 seconds Repeat the process to change back to degree Fahrenheit F AROS 4 b dd 7 P A P A A L4 L4 4 BA E im A bons 4 baer 4 ay bx 4 v ey wre wv wv NT 7 ban rT Tr v w we w y eT 0e 09 0 9009 09 0 0900 09009 090 09009 00 0 09009 09090 0009 0900 0006 000 000 000 000 oe 09 0 9009 09 0 09 090 09 090 09009 090 09 090900 000 0900 000 000 0006 000 00 0000 o 00 09009 090 900 090009 090009 090009 000 0009 000 0900 0
16. n the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Power cord includes a current interrupter device A test and reset button is provided on the plug case The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet If the TEST button does not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician level ruler or tape measure nnn Dn n o hnm TET PARTS INCLUDED oe eee 0o00 Aros air conditioner top mounting rail seal strip top mounting rail left extension right extension type A screws 4 type B screws 6 i LE E window sash seal foam top window gasket window locking bracket 1 AROS 7 2 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the sill Width 2 Length Long enough to fit inside the window frame Thickness To determine the thickness place a piece of wood on the sill to make it 1 2 higher than the top b of the storm window frame or the vinyl frame Attach securely with nails or screw
17. ndow You will need to modify them for other types of windows e The air conditioner can be installed without the side extensions if needed to fit in a narrow window See the window opening dimensions A All supporting parts must be secured to firm wood masonry or metal remove backing seal from seal strip E B The electrical outlet must be within reach of the power cord at l FRONT VIE i i Follow the dimensions in the table and illustration 9 W top mounting rail ES s AROS 8 AROS 9 4 PREPARE THE AIR CONDITIONER Attach the top mounting rail to the air conditioning unit using 4 type A screws oco ors Install right and left extensions by sliding them over the top and bottom mounting rails on each side of Aros cece 99999 23 igo oe eo cee aoe Pull fabric panels from outside edges of the extensions toward the A C unit then snap to secure 9 99 9 of ee 900 ee ots go 9 g p 6 AROS 10
18. not trip or if the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded Where a 2 prong wall outlet is encountered it is your personal responsibility and obligation to have it replaced with a properly grounded 3 prong wall outlet The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires See the installation instructions electrical requirements section for specific electrical connection requirements WARNING USE OF EXTENSION CORDS RISK OF FIRE could cause serious injury or death DO NOT use an extension cord with this window air conditioner DO NOT use surge protectors or multi outlet adapters with this window air conditioner READ AND FOLLOW THIS SAFETY INFORMATION SAVE THESE INSTRUCTIONS AROS 3 OPERATING INSTRUCTIONS ABOUT SMART TECHNOLOGY Aros has smart features that extend its functionality It can be controlled from the Wink app on your mobile device and set to gather information about your schedule location usage and more to help automatically and efficiently maintain the perfect temperature for your ho
19. s provided by the installer M M n 1 2 higher than 1 2 higher than vinyl frame TE E E badain TENE MR Es 00 o d ja uu i TEREE e a T R storm window frame on some windows en cenaeenqneneeee ee0 0 9909999 hu 10 9 TT EEEE ELE draw e SERERE 1 uo NA 9 SEEN 9 brrr 9 NE 8 0 000000009009 TLLA eeeeae eee EE Nc 850682822832h22826008208 8008520250 9 082828 3 ATTACH THE TOP MOUNTING RAIL SEAL STRIP 1 detallan en we au MER b MEX CHE Remove backing from top mounting rail seal strip and nml auwibtueaen nauaa add B T adhere it to the bottom of the top mounting rail E sae 0 0 6 sill 10922299242 2 9 29 EEE E storm window frame vinyl frame top mounting rail 1 WINDOW REQUIREMENTS These instructions are for a standard double hung wi
20. start The fuse is blown circuit breaker is tripped Power failure The current interrupter device is tripped AIR CONDITIONER DOES NOT COOL AS IT SHOULD Airflow is restricted The temp control may not be set correctly The air filter is dirty The room may have been hot Cold air is escaping Cooling coils have iced up AROS 12 WHAT TO DO Make sure the air conditioner plug is pushed completely into the outlet Check the house fuse circuit breaker box and replace the fuse or reset the breaker The unit will automatically restart in the settings last used after the power is restored There is a protective time delay approximately 3 minutes to prevent tripping of the compressor overload For this reason the unit may not start normal cooling for 3 minutes after it is turned back on Press the RESET button located on the power cord plug If the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Make sure there are no curtains blinds or furniture blocking the front of the air conditioner In the COOL mode press temperature decrease Clean the filter at least every 30 days See the CARE AND CLEAN section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace registers and cold air returns See Air conditioner freezing up below PROBLEM POSSIBLE CAUSES AIR CONDITI