Home
CELLSWITCH 100
Contents
1. A SMS will only be sent when an input goes high 5 to 24 volt Input trigger high and low A SMS will be sent when an input goes high or low Input trigger low A SMS will only be sent when an input goes low 0 volt or not connected SMS the reporting numbers Default The device will SMS the reporting numbers when an input is triggered Do not SMS the reporting numbers The device will not SMS the reporting numbers when an input is triggered Page 16 of 23 User Manual for Cellswitch 100 DIGITAL INPUT OPTIONS CONTINUED 1234 F130n 1234 Arm 1234 F130ff 1234 Disarm 1234 F13a Alarm armed 1234 F13b Alarm disarmed Call the reporting numbers The device will first SMS then call the reporting numbers when an input is triggered Do not call the reporting numbers Default The device will only SMS and not call the reporting numbers when an input is triggered Enable the inputs Default If an input is triggered a SMS will be sent Disable the inputs If an input is triggered no SMS will be sent Inputs enabled message When the inputs are enabled this confirmation SMS will be sent back Inputs disabled message When the inputs are disabled this confirmation SMS will be sent back Input 1 trigger delay time Default 0 The time in seconds input 1 must be triggered high before a SMS is sent The delay only works on input 1 It also only works when input 1 is HIGH NOT on LOW
2. Operating Temperature Storage Temperature Operating Humidity Storage Humidity Vibration Resistance Direct Mounting 10 C to 50 C 40 C to 70 C 35 to 85 Relative Humidity No Condensation 35 to 90 Relative Humidity No Condensation 10 to 57 Hz 0 075mm Half Amplitude 57 to 150 Hz 4 9 m s Acceleration Sweep Count for X Y Z 10 times 80 min in each direction Shock Resistance 4 9 m s Acceleration Action Time 11ms 3 times in each direction X Y Z Noise Immunity 1000 Vp p 1 uS 30 to 100Hz Dielectric Withstand Voltage 1500 Vac gt 1 minute tested between all points terminals and ground Insulation Resistance 5Mohm gt at 500 Vdc tested between power terminals and ground PSU Ground Grounding resistance 100ohm or less Caution Units should not be installed in areas subject to the following conditions excessive or conductive dust corrosive or flammable gas moisture or rain excessive heat regular impact shocks or excessive vibration Do NOT use this equipment for medical or mission critical applications as the cellphone networks supply a best effort service and may not always be online Always use a failsafe system in conjunction with this device Take special care not to allow debris to fall into the unit during installation e g cut wires shavings etc Always ensure that the mounted unit is kept as far away as possible from high voltage cables hi
3. DIAGRAM SENSOR 2 OV 12V POWER SUPPLY 12V 500mA GSM ANTENNA OV 12Vdc INPUT 1 INPUT 2 RELAY N O RELAY COM RELAY N C SIM CARD CELLSWITCH 100 Page 6 of 23 User Manual for Cellswitch 100 INSTALLATION Power Supply Wiring Techniques Wiring for the device has been designed to be safe and easy If the user is concerned about the correct installation of these products or associated products please contact a professional electrician who is trained to the local and national standards applicable to the installation site Wiring Cautions e Do not lay I O signal cables next to power cables or allow them to share the same trunking duct Low voltage cables should be reliably separated or insulated with regard to high voltage cabling e Where I O signal lines are used over an extended distance consideration for voltage drop and noise interference should be made Ov 12V POWER SUPPLY 12V 500mA hea a MAAA oP AN OFZ DV TCT oO SOS gt HH Bo 0 A SO BBS 2424 gag HH Aaa aA me fe O 3 Eag z z 5 z z D k E aq r Q General Specifications Power supply Regulated Minimum 5Vdc 500mA Maximum 15Vdc 500mA Max allowable momentary Less than 10ms power failure period Average Power Consumption Output Off 25mA 300mW at 12Vdc Output On 45mA 540mW Average Power Consum
4. Max 24hrs or 86400seconds Page 17 of 23 User Manual for Cellswitch 100 e STEP 5 Program how the output relay must behave when the device is called or sent a SMS Switch the RELAY OUTPUT ON Switch the RELAY OUTPUT OFF Output PULSE mode Default When a voice call is received the output relay will PULSE once Switch on and then off again Output TOGGLE mode When a voice call is received the output relay will TOGGLE Switch either on or off Output relay PULSE duration Default 1 Programs the output relay s PULSE duration in seconds when the device is called i e it will switch on for 5 second and then off again Max 24hrs or 86400seconds Send output switching confirmation SMS When the unit is called sms d and the output relay is switched a confirmation SMS will be sent back Do not send output switching confirmation SMS Default When the unit is called sms d and the output relay is switched no SMS will be sent back Page 18 of 23 User Manual for Cellswitch 100 OUTPUT RELAY OPTIONS CONTINUED 1234 F16a Lights switched on 1234 F16b Lights switched off 1234 F16c Gate Opened 1234 F170n 1234 F1 7off Page 19 of 23 User Manual for Cellswitch 100 e STEP 7 Test the device by checking GSM signal strength inputs and outputs SMS I O CONTROL COMMANDS 1234 Airtime 1234 Off 1234 Arm Page 20 of 23 User Manual for Cellswitch 100 General Specifications
5. User Manual for Cellswitch 100 CELLSWITCH 100 ce CONTROL ANYTHING WITH YOUR CELLPHONE Use your cellphone to remotely monitor and control the following applications with the CELLSWITCH 100 Security Electric Fence Power failure Fire Sensors Alarm Sensors Access Control Open your gate or Garage with your cellphone Home Automation Under Floor Heating Geyser Lights Plugs Stove Industrial Cold Room Monitoring Temperature Monitoring Process Monitoring and Control Farms Pivot control Irrigation Water level Security Page 1 of 23 User Manual for Cellswitch 100 How does it work The Cellswitch is a kind of cellphone you connect to an electronic appliance or device to enable you to communicate with it using your own cellphone You insert a pre paid or contract sim card into the Cellswitch and communicate with by sending it a SMS or by simply calling it as you would SMS or call your friend When the Cellswitch recognise your SMS or cellphone number it will respond in a certain way Any Vodacom or MTN sim card may be used How easy is it to use Your cellphone communicates directly to your Cellswitch 100 with easy to understand SMS commands Simply type a SMS with the words 1234 On and send it to the cellphone number of your Cellswitch and your lights geyser irrigation system etc will switch on from any where in the world Simply SMS 1234 Off to switch it off again Conne
6. confirmation sms back to your cellphone whenever it has been successfully programmed or when you switched its output on or off 500 Programmable Cellphone security numbers Up to 500 programmable cellphone numbers can be recognized by the device when it is used for access control Fully programmable via SMS commands The device is programmed by sending it SMS commands with your cellphone 5 x Programmable reporting cellphone numbers The device can SMS and call up to 5 different cellphone numbers when its input is triggered Daily input output status report The device can send a daily report of its status to your cellphone Machine to Machine interfacing Remotely connect I O s by using two or more Cellswitches to communicate with each other Page 5 of 23 SYSTEM REQUIREMENTS Programming The Cellswitch is programmed by sending it sms messages from your cellphone containing specific commands Whenever a valid command is received by the device a confirmation sms will be sent back to you stating that the device was successfully programmed If the device receives a random sms containing invalid data the sms will be discarded and no sms will be sent back When typing a command make sure of the capital and small letters since the command will not be recognised if typed incorrectly Power Supply 12 Volt dc 500mA SIM Card MTN or Vodacom Pre paid or Contract with PIN disabled CONNECTION
7. ct your Cellswitch to your gate or garage door and call it You can now get access to your property or open the gate for the garden service without even being there The call is free as the Cellswitch does not answer the call but simply recognises the calling number and disconnects the call automatically Please note the Caller Line Identification must be enabled on your cellphone What about security Your Cellswitch will ONLY respond to you and your family s saved cellphone numbers The 1234 in front of every SMS command is a private PIN number that you can change whenever you want How easy is it to program Simply log onto our secure easy to use website https cellswitch accentronix co za register as a user register your Cellswitch 100 by using the cellphone number of the sim card you are using and follow the easy to understand instructions This method is great for a body corporate to add and remove security access control cellphone numbers at security complexes This eliminates the need for remote controls as the Cellswitch can remember up to 500 cellphone numbers Every time someone moves in or out the body corporate simply log onto our website add or remove those people s cellphone numbers hit update and DONE How many different devices can monitor and control With the Cellswitch 100 you can monitor two different devices and control one at the same time In other words you can monitor your alarm system mains power and op
8. en and close your gate with a single device When your alarm trips it will SMS and call you your family and your neighbours notifying them someone is busy breaking into your house You can then phone your neighbour and open the gate for him remotely to go and investigate the situation Getting Started Step 1 gt USING YOUR CELLPHONE ensure that the PIN number of the SIM card is disabled and there is airtime available on the SIM card before inserting it into the Cellswitch Step 2 gt Connect a switch or sensor between 12Vdc and Input 1 Step 3 gt Connect a 12Volt light or electronic appliance device between 12Vdc and Relay COMMON Connect Relay N O Normally Open to OVolt Step 4 gt Connect Power The LED will turn on for a couple of seconds and then start to flash Step 5 gt Phone the number of the sim card inserted into the Cellswitch You will hear the relay click click on the Cellswitch and your call will automatically be disconnected Step 6 gt Send a SMS with the text 1234 On to the Cellswitch and the relay will click only once this time staying on In both steps 5 and 6 you will receive a confirmation SMS back from the Cellswitch Step 7 gt Log onto https cellswitch accentronix co za to setup the device This is a free service we offer to remotely program and manage the Cellswitch from our secure easy to use website Page 2 of 23 User Manual for Cellswitch 100 Important Please read this inf
9. g installed immediately store unit in a well ventilated place away from high temperature humidity dust or metal particles Foreword e This manual contains text diagrams and explanations which will guide the reader in the correct installation and operation of the Cellswitch 100 telemetry device This document should be read and understood before attempting to install or use the unit e If in doubt at any stage of the installation of this device always consult a professional electrical engineer who is qualified and trained to the local and national standards which apply to the installation site e If in doubt about the operation of this device please consult the nearest AccentronixX distributor e This manual is subject to change without notice Page 3 of 23 User Manual for Cellswitch 100 Table of Contents How does is work Caution Key Features System Requirements Connection Diagram Installation Power supply Sim card Antenna Physical Dimensions Digital Input Relay Output SMS Configuration Setup Programming General Specification Diagnostics Technical Support 21 22 23 Page 4 of 23 User Manual for Cellswitch 100 KEY FEATURES 2 x Digital Inputs To monitor alarms sensors etc 1 x Relay Output To switch lights on off open gate garage etc Controllable via voice call Simply call the device with your cellphone to control the output Confirmation SMS The device will send a
10. gh voltage equipment and high voltage power equipment Do not lay signal cables near high voltage power cabling or cabinet housing along the same trunking duct Effects of noise or surge induction may occur Keep signal cables of more than 100mm 3 94 away from these power cables Cut of all phases from the power source before installation or performing wiring work to avoid electrical shock Incorrect operation can lead to serious damage to the product Cut of all phases from the power source before installing removing extension or communication cables to modules to avoid electrical shock incorrect operation or serious damage to product Replace the terminal cover provided after insulation or wiring work is completed and before supplying power and operating the unit to avoid electrical shock When using an incorrect power source or performing incorrect operation serious damage will occur regardless of the level of the voltage and frequency During transportation avoid any impact as the Cellswitch is a precision instrument It is necessary to check the operation of the Cellswitch after transportation in case of any impact damage When storing the Cellswitch conform to the environmental conditions specified by the general specification Terminal screws should be tightened to between 0 5 and 0 8 Nm up to a maximum of 1 2Nm Screws must be secured to prevent a loose connection thus avoiding a malfunction Page 21 of 23 Use
11. imum 25Vdc SENSOR 2 Ov 12V POWER SUPPLY 12V 500mA GSM ANTENNA IN N IN N IN RELAY N C INPUT 1 _ INPUT 2 RELAY com SIM CARD CELLSWITCH 100 Page 9 of 23 User Manual for Cellswitch 100 Relay Output e The output is used to switch circuits on and off and is controlled by sending a sms from your cellphone to the Cellswitch 100 e The output can also be control by calling the Cellswitch from your cellphone When the device receives your call it will automatically disconnect you handling it as a missed call at no charge to you e The output terminals are internally connected to a 2 Amp SPDT relay e N C Normally Closed e COM Common e N O Normally Open Maximum Current 2 Amp Maximum Power 125VA 60Watt Maximum Voltage 250Vac 220Vdc NB To increase the power rating of the output connect a 12V high current relay or contactor to the output terminals 12V Ov POWER SUPPLY 12V 500mA GSM ANTENNA 7 INTERNAL SPDT RELAY C R5232 Page 10 of 23 User Manual for Cellswitch 100 SMS Configuration Setup Programming IMPORTANT _ PLEASE READ BEFORE ATTEMPTING TO PROGRAM THE DEVICE There are three different ways to program this device 1 Via our secure easy to use Gateway website https cellswitch accentroni
12. mand or any other data it will be discarded and no SMS will be sent back When typing a command make sure of the capital and small letters since the command will not be recognised if typed incorrectly The 1234 in front of every command is the default SMS password and it is recommended to change it when setting up the device GENERAL SETUP SECURITY SMS REPORTING OPTIONS DIGITAL INPUT OPTIONS OUTPUT RELAY OPTIONS SMS I O CONTROL COMMANDS Page 11 of 23 User Manual for Cellswitch 100 e STEP 1 Program the device s own name cellphone number and behaviour when it is called GENERAL SETUP 1234 F1 Cellswitch 100 1234 F2 0827727789 Page 12 of 23 User Manual for Cellswitch 100 e STEP 2 Program the desired security settings SECURITY 0 I 1234 F4a 0827727789 0825091827 1234 F4b 0827727789 0825091827 1234 F5a 5678 F5b reserved for SIM PIN Page 13 of 23 User Manual for Cellswitch 100 e STEP 3 Program the cellphone numbers the device must SMS when an input is triggered SMS REPORTING OPTIONS CC EEE 1234 F6a 0827727789 1234 F6b 0827727789 1234 F6c 0827727789 1234 F6d 0827727789 1234 F6e 0827727789 1234 F7on 1234 F7off 1234 F7 12 00 00 SMS Reporting number 1 Programs the first number to SMS and or dial when an input is triggered SMS Reporting number 2 Programs the second number to SMS and or dial when an i
13. nput is triggered SMS Reporting number 3 Programs the third number to SMS and or dial when an input is triggered SMS Reporting number 4 Programs the fourth number to SMS and or dial when an input is triggered SMS Reporting number 5 Programs the fifth number to SMS and or dial when an input is triggered Send daily SMS Status report A SMS will be sent daily containing input output and GSM signal status Do not send daily SMS Status report Default A SMS will NOT be sent daily containing input output and GSM signal status Daily SMS Status report time Default 12 00 00 The time the hh mm ss the daily status report must be sent Page 14 of 23 User Manual for Cellswitch 100 SMS REPORTING OPTIONS CONTINUED 1234 F80n 1234 F8off 1234 F8a 1234 F8b Page 15 of 23 User Manual for Cellswitch 100 e STEP 4 Program the SMS messaged that will be sent when the inputs are triggered 1234 F9a Sensor 1 triggered 1234 F9b Water level LOW 1234 F9c Power restored 1234 F9d Power tripped Input 1 high SMS The SMS that will be sent when Input 1 is High 5 to 24 volt Input 1 low SMS The SMS that will be sent when Input 1 is Low 0 volt or not connected Input 2 high SMS The SMS that will be sent when Input 2 is High 5 to 24 volt Input 2 low SMS The SMS that will be sent when Input 2 is Low 0 volt or not connected Input trigger high Default
14. ormation BEFORE installing the equipment Intended Users This manual is to be available to all persons who are required to install or configure equipment described herein or any other associated operation The information given is intended to highlight safety issues and to enable the user to obtain maximum benefit from the equipment Personnel Installation and maintenance of the equipment should be carried out by qualified personnel A qualified person is someone who is technically competent and familiar with all safety information and established safety practices with the installation process operation and maintenance of this equipment and all the hazards involved Hazards Warning Failure to observe the following will constitute an Electrical Shock Hazard e The power supply connected to this equipment must be permanently earthed e Before working on the equipment ensure isolation of the mains supply e When replacing a unit in an application and before returning to use it is essential that all parameters for the product s operation are correctly installed e This equipment contains electrostatic discharge ESD sensitive parts Observe static control precautions when handling and installing this product Equipment Inspection e Check for signs of transit damage e Check that the power supply and peripheral connected to this device conforms to the specified ratings as described in this document e If the unit is not bein
15. ption Output Off 40mA 200mW at 5Vdc Output On 45mA 540mW In Rush Current 500mA Page 7 of 23 User Manual for Cellswitch 100 SIM Card e Use any Vodacom or MTN pre paid or contract sim e Disable the sim card s pin number before installing it into the cellswitch e It is recommended to use a contract sim to avoid manual airtime top up since most top up packages expire after three months if they are not re charged at least every three months e We recommend the following month to month contract for R9 99 month especially tailored for telemetry devices at http Awww mtn co za FindaPlan Pages priceplan_new001 aspx pkg ProData e For more information on acquiring the above contract please contact us Antenna e Do not install the Cellswitch 100 inside a metal enclosure unless the antenna sits on the outside of the enclosure Physical Dimensions e Length 77mm e Width 67mm e Height 28mm Page 8 of 23 User Manual for Cellswitch 100 Digital Inputs e When the input is triggered either high or low it will send a SMS to the programmed reporting numbers e Terminal IN is internally pulled low Leaving the connection open or connecting it to OV will indicate an Input Low state e When connecting terminal IN to either 12V or Vout will indicate an Input High state e Terminal Vout is internally connected to 12V e Trigger voltage Minimum 3Vdc Max
16. r Manual for Cellswitch 100 Preliminary Checks Diagnostics Before Power up A Power the device up O Check 230Vac Power Supply Wiring O Check Ground Wiring O Check Digital Input Wiring O Check Relay Output Wiring O Check Sim Card Check that Power LED turns on for about 10 seconds then start flashing During Testing During this testing stage take extreme care not to touch any live or electro static sensitive parts LED Indicator Status LED On Power up the LED will stay on for about 10 seconds then start flashing If the LED does not start flashing and stays on do the following checks O Check that the SIM CARD is installed properly O Check that the SIM CARD PIN is disabled O Check that the ANTENNA is installed properly O Check SIGNAL STRENGTH Maintenance e Do Preliminary Checks Page 22 of 23
17. x co za 2 By sending it SMS commands as described below 3 By connecting the device to a RS232 port on your PC We recommend option 1 https cellswitch accentronix co za as this is a free service we offer and it is by far the easiest and most convenient All the data is stored securely on our servers in a data centre It is however important to understand the SMS I O CONTROL COMMANDS section right at bottom of this document To use the website 1 Click on the link https cellswitch accentronix co za 2 Register as a user 3 Register your device using the cellphone number of the sim card inserted pre paid or contract 4 Configure the device settings 5 Click on update on the bottom of the screen 6 Our server will connect to the device update its settings and save it in our secure database Option 2 and 3 at the top may be useful in the field if you are without internet connectivity and for testing the device Please note that all settings will be overridden when using our website to program the device after programming via option 2 and 3 Programming the device via SMS Please follow the step by step instructions below The device is programmed by sending it SMS messages from your cellphone containing specific commands Whenever a command is received by the device a confirmation SMS will be sent back to you stating that the device was successfully programmed If the device receives a random SMS containing a wrong com