Home

Optical splitters and WDM

image

Contents

1. 1310nm amp Optical splitter unit front view 1 Locking screw 2 pcs 2 Tap port 3 Tap port 4 COM port 5 Handle with unit information All optical port connectors are of type SC APC female 8 SC APC 8 optical connection Splitters user manual rev002 The optical SPLITTERS has been designed for splitting optical signals within the CWDM channels in the range of C11 to C18 or standard 1310 and 1550 nm wideband optical windows The units are fully compatible with CFO series system and it can be installed in a standard CSR installation frame or alternatively as stand alone with CMA wall mount adapter The units are 5HP wide All SPLITTER units are passive and require no power supplies Frame installation The unit is to be pushed along the guide rails into the installation frame e g CSR216 or 316 series and secured with the two locking screws The unit can be freely positioned in any slot in the frame The empty positions in the frame should be blanked off with cover plates Stand alone installation The unit can be installed for stand alone use by using a CMA series module adapter The unit is to be pushed along the guide rails into the CMA module adapter and secured with the two locking screws The stand alone unit should be mounted to a vertical surface Fibre connection The dual window optical splitter operate on a standard 1310 nm and 1550 nm signals Available optical s
2. Teleste Corporation Video Networks P O Box 323 FIN 20101 Turku FINLAND www teleste com WEEE directive Directive 2002 96 EC of the European Parliament and of the Council on waste electrical and electronic equipment WEEE obliges that producers appropriately mark electrical and electronic equipment with the symbol indicating separate collection This obligation applies to the equipment put on the market in EU after 13 August 2005 Teleste devices which belong to the scope of the directive have been marked with the separate collection symbol shown below The marking is according to the standard EN 50419 The symbol indicates that the device has to be collected and treated separately from unsorted municipal waste 5 User manual revision history note The latest version is always available in pdf format on our web site www teleste com
3. unit can be freely positioned in any slot in the frame The empty positions in the frame should be blanked off with cover plates Stand alone installation The unit can be installed for stand alone use by using a CMA series module adapter The unit is to be pushed along the guide rails into the CMA module adapter and secured with the two locking screws The stand alone unit should be mounted to a vertical surface Fibre connection When installing the fibre optic cable do not exceed the minimum bending radius when connecting cable to the system For correct optical operation ensure that gt Protect opened connectors always with dustcaps gt Use only 8 angle polished SC APC connectors gt Clean all connectors before mating by using metyl or isopropyl alcohol and dry connectors by compressed air wo Optical WDM connection diagram COM A F F2A 1310 PORT 1260 1360 nm a WDM i n 1310 CWDM 1260 1620 nm CWDM PORT 1460 1620 nm A lt gt bi directional COM A F F1A 1310 PORT 1290 1330 nm a WDM ne 1310 1550 1290 1570 nm 1550 PORT 1530 1570 nm y lt gt bi directional Block diagram Optical WDM block diagram 1310 CWDM 1310 COMMON CWDM Ch11 Ch18 1310 1550 1310 1550 WDM user manual rev002 Optical WDM technical specifications Optical 1310 CWDM Fibre type Wavelength 1310 port CWDM port Insertion loss 1310 lt gt COM port CWDM lt gt COM
4. port Pass band ripple Pass channel isolation Reflect channel isolation Directivity Return loss Polarization dependent loss Connectors WDM user manual rev002 9 125 um 1260 1360 nm 1460 1620 nm 0 8 dB 0 8 dB 0 3 dB 40 dB 40 dB 50 dB 45 dB 0 1 dB SC APC 8 female singlemode reflect channel pass channel CWDM 1310 1310 CWDM Optical 1310 1550 Fibre type Wavelength 1310 port 1550 port Insertion loss 1310 lt gt COM port 1550 lt gt COM port Pass band ripple Isolation Directivity Polarization dependent loss Connectors General Power consumption Supply voltage Connectors Dimensions H x W x D Weight Operating temperature range Storage temperature range Humidity Notes 9 125 um singlemode 1290 1330 nm 1530 1570 nm 0 25 dB 0 25 dB 0 3 dB gt 16 dB 50 dB 0 1 dB SC APC 8 female Passive unit passive unit 3U e 5HP e 190 mm 0 5 kg 34 74 C ma AC 40 85 C 95 non condensing 1310 1550 1310 CWDM Typical values unless otherwise stated Copyright acknowledgements Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation Copyright O Teleste Corporation All Rights Reserved No part of this document may be reproduced transmitted stored in a retrieval system or translated into any other language without the express permission of Teleste Corporation
5. User Manual Optical splitters and WDM gt LESTE Optical passive CWDM wideband amp dual window splitters and wavelength division multiplexer demultiplexer products 1310UwWY MDN Video Networks Splitters and WDM user manual 59300282 rev002 Welcome and thank you for purchasing Teleste s video networking products Contents Optical Splitters IMtrOGUCTION ci 53 cases ixnincanatananasnsessneieneaesnndvaananananianattdninduandsanknwenseenmniantndthadantannnnennsctansdansaasnansmannanns 1 General ocacion coi Rada 1 Frame Installation aiii AE ARa 1 Stand alone InstallatiON coi bucvaedacaantauuatdeaanasecancanadeoenae 1 FIBRE COMME CUO ii A A A E a aaa a A AA A A 1 Optical splitters connection diagram ccccccecceceeeeeececeneecaeceeeeeeeeeeescaaeaaecaeceeeeeeeeesescaaaaaecaeeeeeeeseesecsucsaaeeeeeees 2 Optical splitters technical SpeCifiCAtIONS cece eee eeeeeeeeee cee ce ee eaa Aa ENa NA E aT 2 Optical WDM IntroductiON lt 2 csi iia a A aii 3 General cantata a A a E 3 Frame Installation oi iars 3 Stand alone Install ON tias ARA A AAA ai pando 3 FIDE CONNECION a 3 Optical combiners block dla Minivan ta A A A AA A az 4 Optical combiners technical Specifications oooooncnninicconcocncnnnnncnocnnnnnnnnoncnnncnnnnnnnnnnnnnnnn nn nn n nn nn nn nn n ran nnnnnn nn nnnnnn 5 Splitters amp WDM user manual rev002 Optical splitters introduction Wideband amp dual window splitter units
6. formity 0 8 dB Directivity 50 dB Connectors SC APC 8 female 2 singlemode singlemode 50 50 30 70 General Power consumption Passive unit Supply voltage Passive unit Dimensions H x W x D 3U e 15HP e 190 mm Weight 0 5 kg Operating temperature range Wideband CWDM 10 70 C Dual window 400 785 C Storage temperature range 40 85 C Humidity 95 non condensing Notes Typical values unless otherwise stated Splitters user manual rev002 Optical WDM introduction Wavelength division multiplexer demultiplexer units 1310nm 8 1550nm Optical WDM front view 1 Locking screw 2 pcs 2 1310 nm port 3 1550 nm port 4 COM port 6 Handle with unit information All optical port connectors are of type SC APC female 8 SC APC 8 optical connection WDM user manual rev002 The optical WDM unit can be used to combine the CWDM channels in the range of C11 to C18 with existing 1310 nm legacy systems or for combining standard 1310 1550 nm optical signals The unit is fully compatible with CFO system and it can be installed in a standard CSR installation frame or alternatively as stand alone with CMA wall mount adapter The units are 5HP wide All WDM units are passive and require no power supplies Frame installation The unit is to be pushed along the guide rails into the installation frame e g CSR216 or 316 series and secured with the two locking screws The
7. plit ratios are 50 50 30 70 The wideband CWDM optical splitter operate on CWDM channels in range C11 to C18 Available optical split ratio is 50 50 When installing the fibre optic cable do not exceed the minimum bending radius when connecting cable to the system For correct optical operation ensure that gt Protect opened connectors always with dustcaps gt Use only 8 angle polished SC APC connectors gt Clean all connectors before mating by using metyl or isopropyl alcohol and dry connectors by compressed air Optical splitters block and connection diagram 1310 8 1550 50 30 CWDM TAP 1460 1620 nm CWDM TAP 1460 1620 nm OPTICAL SPLITTER CWDM Ch11 Ch18 COM PORT 1460 1620 nm lt lt bi directional 1310 1550 TAP 1270 1350 nm 1510 1590 nm 1310 1550 TAP 1270 1350 nm 1510 1590 nm Optical splitters technical specifications OPTICAL SPLITTER 1310 amp 1550 COM PORT 1270 1590 nm lt lt bi directional Optical wideband CWDM CWDM Fibre type 9 125 um Wavelength 1460 1620 nm Split ratio 50 50 Insertion loss 3 8 dB 3 8 dB Uniformity 0 7 dB Directivity 55 dB Return loss 50 dB Connectors SC APC 8 female Optical dual window 1310 amp 1550 Fibre type 9 125 um Wavelength 1310 nm window 1270 1350 nm 1550 nm window 1510 1590 nm Split ratio 50 50 30 70 Insertion loss 3 6 3 6 dB 5 8 1 9 dB Uni

Download Pdf Manuals

image

Related Search

Related Contents

Franklin BQL-2066 eBook Reader User Manual  Cables Direct 15m USB 2.0 Active Repeater  Manual - Fourstar Group Customer Support Site  Fila PS/87  Rexel T78654 folder  Introduction de la notion d`équation différentielle :  RCA RTD315W User's Manual  DIGI IV & V - partirentournee  Enterobacter sakazakii Real Time PCR Kit User Manual For  PDFファイル  