1. 4 3 Transmission Required Time 5 Transmission Required Time 5 1 In the case of input Because the master side does not update data double collation unless the same data consecutively continues two times the transmission cycle time requires transmission time of a minimum one cycle time and maximum two cycle time Signals of two cycle times or less may not be captured depending on the timing Therefore in order to ensure a response provide an input signal of two cycle times or longer Minimum transmission Se time Case of minimum 1 cce time transmission cycle a Change in input data Input data update Maximum transmission cvcle time Case of maximum A 2 cvcle times 3 transmission YE 9 TER cycle A Change in input data Input data update 5 2 In the case of output Because the slave unit side performs double collation it requires transmission time of a minimum one cycle time and maximum two cycle times similar to the case of input Terminology Cycle time Repeated transmission time of actual data transmitted Maximum transmission delay time Processing time on master side Transmission cycle time Signal delay time on slave side Response delay time is as shown in the following diagram Input and Input Output output equipment a 1 Input equipment response time I I l 9 Output equipment response time 1 I AnyWire fr21 Stave side signal delay time A e Slave side sig
2. ASLINK filter Type ANF 01 or COSEL CO LTD Type EAC 06 472 to 24V and OV at the position where all of the lines start to run In addition when conforming with CE standards insert the ASLINK filter Type ANF 011 regardless of installation method and distance Quick Start 1 Quick start Outline of procedures to use AnyWireASLINK system and recommended conditions to operate in a more stable state are described Refer to the contents described in chapter 2 and later for details on each item Example of description When using interface QJ51AW12AL for Q series sequencer of Mitsubishi Electric Corporation 1 1 Installation 1 Wire material of transmission line See P2 10 2 4 3 Transmission cable type and precautions It is possible to lay with general purpose VCTF cabtire cable 2 core transmission line only or 4 core transmission line power line 2 Wire diameter of transmission line See P 2 10 2 4 3 Transmission cable type and precautions 0 75mm 1 25mm 3 Number of slave units connected See P 2 5 2 3 4 Number of slave units connected Up to 128 units 4 Power supply See P 2 13 Install power supply dedicated for AnyWire or power line directly branched from power unit Transmission signals and power can pass through either separate cables or through a bundled cable If a voltage drop is taken into consideration local power supply is recommend
3. General purpose switch Input output unit sensor LED solenoid valve relay etc input output 4 points 4 points Relay output AC drive load etc 8 point relay output G2R relay mounting ane type Dedicated ee For solenoid valve manufactured Fesil Kreml s re General purpose input ASLINKSENSOR Digital link sensor head ASLINKAMP ASLINKAMP Manifold driver driver AnyWireASLINK Confirm the model name and type of the master unit and slave unit by the separate AnyWireASLINK system catalog 2 3 4 Number of slave units connected Number of slave units which can be connected to one line of AnyWireASLINK system is maximum 128 units It is necessary that sum of slave unit occupying point number and sum of consumption current for transmission line meet both conditions of maximum transmission point number or less and allowable supply current or less 2 3 5 Connection of slave unit There are roughly two types of methods for connection of slave unit of AnyWireASLINK One method is the 2 wire non insulation type and the other method is the 4 wire insulation type This depends on the slave unit Any configuration of 2 wire type only 4 wire type only and mixture of 2 wire type and 4 wire type can be used as a combination C ASUNKER o Type ASLINKTERMINAL ASLINKAMP ASLINKSENSOR Cable type M12 connector type 2 wire non insulation 0 eo xx 0 gt 4 wire insulation o l o o PP
4. If 2 core and 4 core electric wires are mixed they can be mutually connected by using an LP connector link connector N for a 4 core electric wire even for a 2 core electric wire In that case also set electric wires so that the black electric wire is on No 1 of the connector cover and connect wires as No 3 4 are kept blank Black For 4 core electric wire diameter of 1 25sq For 2 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 1 25sq N GN 3 1 3 Check that the small hook engages For 4 core electric wire diameter of 0 7550 KL For 4 core electric wire diameter of 1 25sq For 2 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 1 25sq he 4 Insert a connector body into the connector body of 3 Four electric poles rising from the connector body enter four holes of the connector cover For 4 core electric wire diameter of 0 75sq Large hook Connector body Connector body hole sem part Hole where electric pole part enters e Connector body For 4 core electric wire diameter of 1 For 4 coreelectrc wire diameter of 1 255q For 2 core electric wire diameter of 0 For 2 coreelectic wire diameter of 0 7559 For 2 core electric wire diameter of 1 For 2 coreelectic wire diameter of 1 2559 gt amp 5 Swage in the state of 4 with a dedicated tool LP TOOL In that case check that the snapping sound is heard and four large hook
5. MELSEC L CC Link IE field network Head unit user s manual Check error of the sequencer with a Check error contents by PC diagnosis of the programming tool programming tool to take measures 2 When LINK LED on the master unit does not flash Check items Description of measures Check error of the sequencer with a Check error contents by PC diagnosis of the programming tool programming tool to take measures 3 When ALM LED on the master unit lights up or flashes 1 ALM slowly flashes period of one second DP DN short circuit error Check items Description of measures Check that transmission line DP DN is not Check that the transmission line DP DN is not short circuited short circuited Be careful not to mistake pin assignment when crimping the link connector Check wiring of terminal block Check that there is no contact of the transmission line DP DN and no improper wiring on the terminal block in the master unit or the slave unit Check that consumption current of the Modify cable wire diameter total extension and AnyWireASLINK system meets the unit type number of connections so that specification consumption current of all of the slave units is less than transmission line supply current value of the master unit Troubleshooting 2 ALM quickly flashes period of 0 2 seconds Transmission circuit drive voltage drop error Check items Description of measures Chec
6. e Branching between cabtire cables X RY E e Conversion to a dedicated flat cable NN RRE FaF Tr Ka aa AnyWireASLINK m Multi drop method The multi drop method is a way to connect slave units directly to cables When applying this method neither new cables nor non cable connecting equipment is required ne hit kk u amp oO Bees In the actual wiring as shown below the signal lines of transmission cables from one side and those of transmission cables from the other side are integrated and connected to the slave unit m Tree branch method The tree branch method is a way to re connect the T branched stay line using the T branch method or multi drop method e BORE EEEE CH i WWW EGG OH e DEER fe 4 6 Te oe ieh Actual wiring will be the same as the T branch method or multi drop method m Star branch method The star branch method is a way to connect the master unit and lay Loi cable radially from a certain branching point to connect the slave unit This method allows for bundling transmission channels easily On the other hand it tends to cause reflection easily AnyWire is not susceptible to reflection by a transmission method with a low speed transmission clock however lay cables at the shortest distance with the minimum number of branches as possible AnyWireASLINK 2 4 2 Transmission distance All Transmission Distance
7. 1KP B283SB 01 1KC OSE No transmission wave B283SB PC SET LINK Flashinghemmmund B283SB 01 1KR V Flashing s 4 Green JE B283SB 01 1KS LED indication unit DP DN disconnected or no power supply Sensing level reduced B297SB 01 1K40 yellow Flashing amp Transmission signal level reduced ee flashing Master unit detecting the unit ID m LED indication unit IE address redundant or not set Proximity type shield type LED indication Cylinder type Indication status Detailed status No transmission wave LINK f Green Flashing B295SB 01 1K24 B295SB 01 1K25 Be95SB 01 1K26 B295SB 01 1K27 LED indication unit DP DN disconnected or no power supply Sensing level reduced B285SB 01 1K1 Red Flashing Transmission signal level reduced LINK Alternate flashing Master unit detecting the unit ID ALM LINK besse LED indication unit A ae address redundant or not set LED indication VO Seen 1 or See the manuals of each model for details Detection distance Pressure integrated type Indication status Detailed status All target types o No transmission wave LINK Green Flashing 4 for DI DP DN disconnected or no power supply On e Sensing level reduced Red Flashing 4 Transmission signal level reduced LINK Alternate od Master unit detecting the unit ID ALM address redundant or not set B284SB 01 1KLIP380 ON On INO VO B28
8. Body Black For 4 core flat cable 0 7559 Coating outer diameter 6 2 54mm Cover White Body Black Pin protector type For cabtire cable Coating outer diameter 1 1 to 1 4mm Cover White Body White 4 pole type Body color For cabtire cable Coating outer diameter 1 8 to 2 1mm Cover Yellow Body Black Red for wire diameter size 1 25sq Black for wire diameter size 0 75sq For cabtire cable Coating outer diameter 62 1 to 2 4mm Cover Orange Body Gray Gray for wire diameter size 0 5sq White for wire diameter size 0 3sq For cabtire cable Coating outer diameter 1 8 to 2 1mm Cover Yellow Body Gray EE Crimping tool dedicated to LP connector The connector can be crimped by pliers etc however Crimping tool for LP connector a dedicated tool is recommended If 2 core and 4 core electric wires are mixed they can be mutually connected by using an LP connector link connector for a 4 core electric wire even with a 2 core electric wire For cabtire cable Coating outer diameter 2 1 to 2 4mm Cover Orange Body Black 1 1 3 Crimp to flat cable end Signal assignment for a flat cable is as shown in the following table t l according to the AnyWire standard identification color in No D D ORRO 4 core Red Wire color Black Brown in case of electric White Green wire diameter of 1 25sq m REESEN 2 core Red White spiral on red in Wire color Black case of electric wire diameter of 1 25sq This
9. Guide If any of the side by side lines of DP DN 24V and OV exceeds the total length of 50m 2 wire terminal 4 wire terminal 3 8 Design m Connection example of ASLINK filter ANF 01 for local power supply AnyWireASLINK master DP DN SEN General purpose power supply filter Use it if necessary 7 ANF 01 24V DC stabilized power supply I 000 I mL POWER IN PE OV 24V OV 24V If any of the side by side lines of DP DN 24V and OV exceeds the total length of 50m 24V DC stabilized General purpose power ly filt I Power supply ae ae ON DL ov OFG Q O DG POWER IN al L OO ANF 01 Use it if necessary PE OV 24V A big DN 4 wire AN terminal same OV E ODP ODN 4 wire y 924V terminal nz DOV If A B of the side by side lines of DP DN 24V and OV exceeds the total length of 50m eh 2 wire terminal 4 wire terminal 4 wire terminal 2 wire terminal 2 wire terminal Mi Filter notation in the drawing POWER IN PE OV 24V For details of ANF 01 refer to ANF 01 Products Guide 4 wire terminal 4 wire terminal 4 wire terminal 3 9 Connection of Transmission Line 4 Connection of transmission line 4 1 Removal of connector When removing AnyWireBus side connector check that the fixing screws on both ends are definitely loosened removed from the socket and pull it out I
10. Three types of connections are allowed by combining the above crimps cable middle crimp and cable end crimp l SE Addition For link connectors any combination of coupling between connectors is acceptable as far as the number of poles is the same T type branch H type branch Example of T type branch For flat cable 4 core electric wire diameter of 1 25sq For flat cable 4 core electric wire diameter of 0 75sq For flat cable 2 core electric wire diameter of 0 75sq For flat cable 2 core electric wire diameter of 1 25sq For cabtire cable 6 1 Anywire Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Website http www anywire jp E Mail inquiry info e Q anywire jp
11. enters Connector cover p IT Connector body For 4 core electric wire diameter of 1 25sq For 2 core electric wire diameter of 0 7550 For 2 core electric wire diameter of 1 25sq 5 Swage in the state of 4 with a dedicated tool LP TOOL In that case check that the snapping sound is heard and four large hooks of the connector cover securely engage with the connector body holes Before swaging After swaging For 4 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 1 25sq 2 3 6 Now crimping is completed It is not allowed to disassemble the connector after crimping and re use it at the time of failure and layout change etc For 4 core electric wire diameter of 0 75sq For 4 core electric wire diameter of 1 2559 Q For 2 core electric wire diameter of 0 75sq Viewed from front Viewed from side For 2 core electric wire diameter of 1 25sq 4 Crimp to the middle of flat cable Signal assignment for flat cable is the same as that in the previous section See the table in page 2 1 1 Prepare a connector cover Cut the end face part at the tip end with nippers or the like For 4 core electric wire diameter of 0 75sq For 4 core electric wire diameter of 1 25sq For 2 core i CUT End ace part P 2 Place a flat cable on a connector cover and close the connector cover For 4 core electric wire diameter of 0 75sq Small hook
12. relationship between color combination and signal is a base for connection of devices 1 Prepare a connector cover For 4 core electric wire diameter of 0 75sq For 4 core electric wire diameter of 1 25sq ef 2 Place a flat cable on a connector cover and close the connector cover For 4 core electric wire diameter of 0 75sq If 2 core and 4 core electric wires are mixed they can be Small hook mutually connected by using an LP connector link connector oa for a 4 core electric wire even for a 2 core electric wire In that case also set electric wires so that the black electric wire is on No 1 of the connector cover and connect wires as No 3 4 are kept blank Black a For 4 core electric wire diameter of 1 25sq For 2 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 1 25sq i ch 2 1 3 Check that the cable end face is not deviated from the connector cover and the small hook engages For 4 core electric wire diameter of 0 75sq For 4 core electric wire diameter of 1 25sq For 2 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 1 25sq 4 Insert a connector body into the connector body of 3 Four electric poles rising from the connector body enter four holes of the connector cover For 4 core electric wire diameter of 0 75sq Connector body hole Connector body Large hook Large hook Electric pole part Hole where electric pole part
13. 45B 02 1KLIP30 ON Orange E 3 oO Q UI al B284SB 02 1KCIP30_ON a i B2845B J1 1KP30 does not have LED indication for VO Troubleshooting Checklist by symptom Symptom Check items Master unit side Power is supplied to the master unit Address is properly assigned and program properly corresponds to Data cannot be input and lt accesses buffer memory output Slave unit side Power is supplied to the slave unit Address of the slave unit is correctly set Slave unit of the same specification and setting like that of the master unit such as number of input and output is used DP DN lines are not disconnected ALARM LED Red lights Automatic address identification operation was correctly up performed Screws on the terminal blocks are not loosened ALARM LED Red DP DN lines are not short circuited ALARM LED Red The voltage of 24V DC power supplied to the master unit is Warranty 7 Warranty m Warranty period The warranty period of a delivered product shall be one 1 year after delivery at the place specified by an orderer m Scope of Warranty In the event that a failure occurs under normal use conditions within the product specification range in accordance with this user s manual during the warranty period above the failed portion of that equipment shall be replaced or repaired without charge However in the case where a delivered product falls under any of the following it shall
14. 4V and OV exceeds a ae yh wire OV AnyWireASLINK 2 6 Address setting reference Address setting of slave unit determines from what number of bit in AnyWireASLINK transmission frame each slave unit is associated Each terminal occupies the area of its own point number with the set address number placed at the head from the position Address can be freely set from 0 to 254 respectively for input and output Example 8 point terminal When address is 0 0 to 7 bits are occupied in transmission frame Transmission frame No 0 No 7 No 254 Set address so as to avoid bit interference Address 0 Address 8 p No O to 7 are occupied No 8 to 15 are occupied N in transmission frame in transmission frame Example Address of slave unit is handled by decimal number Write a value you want to set in the slave unit by the dedicated address writer ARW 04 ARW 03 Address of slave unit is set to 255 before shipment The slave unit does not operate in this state Before use write any value other than 255 when turning on power for the first time There is no problem if 255 is included in the occupied numbers Example Set address 254 to 2 point occupied terminal and use 254 and 255 It is necessary to take into consideration so that the area which the slave unit occupies does not exceed the transmission point number setting set on the maste
15. Anywire Anywire Corporation AnyWireASLINK System Technical Manual First edition May 28 2015 Small and Fewer Points Sho Haisen Transmission AnyWire ASLIN K system System Responds to On site Diagnostics PMA 11032A Precautions Precaution related to this manual 1 This manual describes the overall concepts of the AnyWireASLINK system Make sure to read the individual User s Manual before use and understand the specifications and handling of the respective product 2 Reprint or duplication of part or all of this Manual without permission is prohibited 3 Contents of this Manual may be subject to future changes without prior notice Safety precautions Make sure to read before use When using this product please carefully read this Manual and the related Manuals introduced in this Manual and pay sufficient attention to safety in order to handle this product properly The precautions in this Manual describe only matters related to this product Refer to the User s Manual of the CPU unit for safety precautions as a sequencer system This Safety precautions ranks the safety precaution items into NWARNING and AN CAUTION N Improper handling may cause a dangerous situation and can result in WARNING death or serious injury Improper handling may cause a dangerous situation and can result in A N caution moderate injury or minor injury or is assumed to result in property damage L
16. Legend o With x Without For basic configuration connection with 2 wire type is assumed and not only the transmission signals but also power to operate the terminal and equipment on the load side are superimposed on those 2 wire When current capacity of the load side exceeds the upper limit of the transmission line supply current value in the AnyWireASLINK system consisting of 2 wire type use 4 wire type AnyWireASLINK 2 4 Transmission line DP DN AnyWireASLINK protocol which is a low speed transmission clock realizes a high speed effective transmission clock and is compatible with broad cable characteristics therefore various transmission cables and general purpose electric wires can be used as a transmission channel 2 4 1 Connection mode AnyWireASLINK Bus allows for various connections such as T branch multi drop and tree branch T branch Multi drop T branch method The T branch method is a connection method to branch out a cable from an insulation displacement connector or terminal stand to connect the slave unit Actual wiring is shown below AnyWireASLINK e When an insulation displacement connector is used A flat cable is branched using an insulation displacement connector as described below a i m e When a terminal stand is used A cable can be branched as follows using a store bought terminal stand a terminal stand with which terminal stands face to face are internally connected
17. Mi LIDT 14 AMOYV GI FAX 00 R15 LOX Be Kar 100 galas K15 Insert user program in this space END Each signal corresponds to device as follows according to the above program Type of signal Corresponding device Input 256 points X100 X1FF Output 256 points Y100 Y1FF Design Reference BMOV command Format BMOV A B C A Head input output number of QJ51AW12AL Designation with upper two digits when head input output number is expressed in three digits of hexadecimal number and head address of data read Buffer memory address B Device head number of storage destination to store read out data C Number of transfer data Function Batch transfers 16 bit data at C point from the device designated at A to the device designated at B 3 3 P ower supply AnyWireASLINK system uses a stabilized 24V DC power supply Required power conditions are as follows Ripple 0 5Vp p or less Master unit transmission circuit drive power Supply voltage 21 6 DC 27 6V 24V DC 10 15 Recommended voltage 26 4V DC 24V DC 10 Insulation type slave unit drive power Allowable voltage range 21 6 DC 27 6V 24V DC 10 15 Power for load connected to slave unit When conforming with UL standards make sure to use an NEC Class2 stabilized power supply 3 3 1 How to supply power AnyWireASLINK system allows for both of a method to drive master unit and slave unit insulation type respectively by separate
18. T OUTPUT DATA 3 1 3 2 EXAMPLE OF PROGRAM ses ee en ee ee 3 2 33 PRS PN hr 3 3 3 3 1 How to supply power LS EW 3 3 2 Power supply COMMON Lavere eneren 3 6 3 4 ANYWIREFIETER ser 3 7 4 CONNECTION OF TRANSMISSION LINE rrrrrrrrrnnnnvnrrvnnnnnnnernvnnnnnnernnnnnnnnevennnnnnnsvennnnnnnssennnnnnee 4 1 4 1 REMOVAL OF CONNECTOR nee 4 1 4 2 TRANSMISSION LINE BUILDING BY LINK CONNECTOR 4 3 5 TRANSMISSION REQUIRED TIME sarissa 5 1 dct INTHE CASE Or INPUT pe 5l 92 INTHE CASE OF OUTPUT 2 51 6 TROUBLESHOOTING nalen 6 1 og VISUVABCHECK NNN 6 1 6 2 CHECK WITH BUFFER MEMORY EXAMPLE OF GUS ANTZAL 6 1 63 LED STATE OF MASTER UNIT ss 6 2 6 4 LED STATE OF THE SLAVE UNIT sos 6 4 6 4 1 Display and contents of each model 6 6 T WARRANTS 7 1 8 CHANGE HISTORY PN 8 1 Introduction Introduction Thank you for considering AnyWireASLINK system Unprecedented AnyWireASLINK system allows for wiring saving up to IO 1 point to 1 point with fewer point and multiple distribution configuration by unique full double duplex method This system uses a transmission chip which was independently developed by AnyWire Corporation and has high noise resistance and high reliability This system has been designed to provide optimum sensor level bus applications Fully understand the functions and performance in use for building a sensor network system Example of configuration Spe AnyWireASLINK master unit Mitsubishi E
19. abilized power Connect D G 24V and OV to D G 24V and OV of the slave unit respectively Example when local power is supplied by dedicated flat able Local power supply EEE PA v Local supply power range Design bg CAUTION Position of power unit Do not supply power to the master unit from a power source placed at a local position such as out of the panel as shown in the Improper example of how to supply power to the master unit Reference voltage of transmission signals is in an improper state resulting in transmission failure For power supply to the master unit distance between the power and the master should be as short as possible for example place in the same panel and supply power through a directly branched wire from the power terminal whenever possible m Example of improper power supply to master unit F S ed 3 3 2 Power supply common 3 6 Wires with the same symbol are internally connected by pins and terminal blocks in the slave unit COM terminals among them are prepared in place of power crossover for input output load to be connected and connected with power terminals in advance before shipment Refer to the instruction manual for details on each product Example COM and 24V are internally short circuited for NPN output in screw terminal block output unit For particularly unspecified slave unit such as relay output termina
20. be excluded from the scope of warranty 1 In the case where the failure was caused by improper handling and use by the customer 2 In the case where the failure was caused by a reason other than the delivered product 3 In the case where the failure was caused by alteration or repair by a person other than supplier 4 In the case where the failure was caused by a natural disaster and others for which the supplier has no responsibility Warranty in this section means the warranty of a single delivered product and we assume no responsibility for any damages caused by a failure of the delivered product Change History 8 Change History Date Change Description First edition May 28 2015 8 1 Reference How to crimp link connector to flat cable cabtire cable 1 Introduction Link connector is a male and female integrated crimp type connector and allows for additional coupling and branching connection with connectors having the same number of poles to dedicated flat cable and cabtire cable This connector can basically be crimped using pliers however dedicated tools are also sold in addition to pliers In the case of operation using pliers Keep in mind that the finish condition coupling and contact of housing may vary depending on number to be processed and level of skill Thus we recommend a method with a dedicated tool which allows for a constant operating condition even if multiple wires are pr
21. ctor cover securely engage with the connector body holes Before swaging After swaging 5 Now crimping is completed It is not allowed to disassemble the connector after crimping and re use it at the time of failure and layout change etc 6 Crimp to the middle of cabtire cable Signal assignment for cabtire cable is the same as that for flat cable See the table in page 2 1 1 Peel the coating at a position where you want to branch Before peeling After peeling 2 Cut the end face part of the connector cover with nippers or the like CUT End face part NS 3 Place a cabtire cable on a connector cover and close the connector cover Check that the hooks have entered the grooves without deviating Be Small hook 9 1 4 Check that the small hook engages 5 Insert a connector body into the connector body of 4 Four electric poles rising from the connector body enter four holes of the connector cover Large hook Connector body hole r Connector body 6 Swage in the state of 5 with a dedicated tool LP TOOL In that case check that the snapping sound is heard and four large hooks of the connector cover securely engage with the connector body holes Before swaging After swaging 9 2 7 Now crimping is completed It is not allowed to disassemble the connector after crimping and re use it at the time of failure and layout change etc 9 3 7 Connection
22. current 5 When LINK ALM alternately flashes The master unit of this system has duplicated ID address or performs no initial setting on this unit therefore check presence absence of address and initial setting and set them again Troubleshooting 6 When ALM lights up and LINK I O flashes in synchronization The connection cable of 2 wire type sensor connected to this unit is disconnected For 2 wire type sensor only disconnection can be detected Check presence absence of disconnection on the common side and I O side Troubleshooting 6 4 1 Display and contents of each model m ASLINKER on note plage Nom _ Jor OP On coed orro ower anny on vo ponere au or tom o ALM Alternate flashing Master unit detectin i g the unit ID LINK LINK address redundant or not set AM I O Orange BL287 1B 02F 0CC20 BL287 1B 02FS CC20 ES on E pr EE EECH on gaeren LEID indication LED indication Alternate flashing Master unit detecting the unit ID LINK address redundant or not set AM mm I O disconnection LINK seess ALM on and O flashing Flashing VO mexan synchronously with LINK B2811_B O2U CC20 B280 1B 02U C 1220 B281 B 02US CC20 B280 _B D2US C 1220 LED LED indication unit indication unit sASLINKTERMINAL Indication status GING reet Noma Red Flashing t 4 Master unit detecting the unit ID address red
23. e master detects this and immediately stops transmission and notifies an error and at the same time flashes the master unit side ALM lamp A function is equipped to recognize an address ID set for the connected slave unit and notifies an error if there is any redundant or non set unit AnyWireASLINK 2 3 Product outline 2 3 1 System configuration AnyWireASLINK system consists of master unit slave unit and peripheral devices Master unit Terminator For output For input For output For input 2 3 2 Types of master unit Use master unit for AnyWireASLINK system There are the following types of master units Details of compatible models Master unit for sequencer MELSEC Q L F Bridge for field bus connection CC Link CC Link IE Field Gateway for field bus connection Devicenet PROFIBUS EthernetIP Master unit and bridge unit for sequencer are jointly developed products of Mitsubishi Electric Corporation AnyWireASLINK system can be established below the sequencer and CC Link of MELSEC Q series by using these units Confirm the model name and type by the separate AnyWireASLINK system catalog 2 3 3 Types of slave units Use slave units for AnyWireASLINK system for the above master unit There are the following types of slave units Example of devices to Details be connected ASLINKER Input 2 points output 2 points input output 1 point 1 point ASLINKTERMINAL Input 8 points output 8 points
24. e tightening may result in dropping short circuit or malfunction Excessively tightening screws may cause damage to the screws or unit resulting in dropping short circuit or malfunction e Make sure to shut off all phases of the external supply power used in the system for installation and removal of the unit Unless all phases are shut off the product may be damaged e Do not directly touch the conductive sections and electronic components of the unit This may result in malfunction or failure of the unit Precautions for wiring Tighten the terminal screws within the specified torque range Loose tightening of the terminal screws may result in short circuit fire or malfunction Excessive tightening of the terminal screws may cause damage to the screws or unit resulting in dropping short circuit or malfunction Be careful to prevent foreign matter such as cutting chips and wiring offcuts from entering into the unit Fire failure or malfunction may result Precautions for wiring In order to prevent foreign matter such as wiring offcuts from entering into the unit at the time of wiring an entry prevention label is attached on the upper part of the master unit Do not remove this label during wiring work Make sure to remove this label to discharge heat when operating the system Improper wiring may damage the equipment Be careful with regard to the label length and layout so that connectors and electric wires are not disc
25. ed Voltage of power supply to QU51AW12AL Voltage within 24V 0 5V is recommended Voltage of power supply to slave unit Voltage should be within 21 6V to 27 6V 5 Setting to sequencer Attach QJ51AW12AL to the predetermined sequencer slot position to set number of transmission points Perform this setting in Intelligent function unit switch setting of QU51AW12AL by GX Developer and GX Works2 Set assignment destination for the system information and I O data etc of this unit Quick start 6 Address setting See P 2 19 Address head number to assign into transmission frame setting is required for each slave unit Use a dedicated address writer to perform address setting The set address number is placed at the head and area for number of points is occupied for each slave unit What part of buffer memory in the master unit the data is assigned is determined by this setting Area to be occupied should not exceed the range of number of transmission points set in 5 Wiring Connect between the transmission line terminals DP DN of the master unit and the slave unit Branch wiring is allowed however wiring should be as short as possible Terminator See P 2 12 Make sure to connect one terminator to the transmission line end farthest from the master unit If there is any branch of 40m or longer also connect it to the end A transmission waveform shaping circuit is incorporated and there are pola
26. ed or the power is turned OFF Even if ID duplication is detected operation of the slave unit is not limited Input output are normally received transmitted The ID non set slave unit does not operate AnyWireASLINK 2 10 Installation of devices 1 Use the AnyWireASLINK master unit according to the installation standards of each sequencer 2 AnyWireASLINK devices are as follows 1 ASLINKER ASLINKTERMINAL Relays are excluded When they are directly installed there is no limit to the installing direction When installing DIN rail install it so that the horizontal or fixing hook is placed upward MN ee See GE Up DIN rail DIN rail DIN rail Fixing hook U Up A jor De jw w oji 2 3 4 5 6 7 lalalalalala lalalalala DN DN ov ov ww 20 faw ww ww DIN rail DIN rail AnyWireASLINK 2 ASLINKTERMINAL Relay is mounted When it is directly installed there is no limit to the installing direction When installing DIN rail install it so that fixing hook is placed upward However prevent acceleration from being applied in the contact opening closing direction for any case Acceleration Fixing hook DIN rail 3 ASLINKAMP When installing DIN rail install it so that the horizontal or fixing hook is placed upward Fixing hook 4 Up DIN rail DIN rail Nee 7 NN 4 ASLINKSENSOR Photoelectric sensor is excluded There is no limit to the installin
27. ent momentary stop and significantly reduce cause investigation time at the time of failure Various setting items which the Digital Link Sensor has can be read and written from the higher side and man hours to adjust individual device are also significantly reduced 2 2 Specifications 2 2 1 General specifications Operating ambient temperature 0 C 55 C Storage ambient temperature 25 C 75 C Operating ambient humidity l 10 90 RH no condensation 1 Do not operate or store the AnyWireASLINK equipment in an environment pressurized above atmospheric pressure at an altitude of Om Malfunction may result 2 This is an index showing the degree of generation of conducting substance in an environment where the equipment is operated Pollution level 2 means generation of non conducting pollution only However temporary conduction may occur by accidental condensation in this environment AnyWireASLINK 2 2 2 Performance specifications Wire l DP DN allowable i Transmission distance diameter supply current Less than 2A Transmission distance Exceeding 50m shorter than 100m Less than 1A supply current value Exceeding 100m shorter than 200m Less than 0 5A Shorter than 50m Less than 1 2A 0 75 mm Exceeding 50m shorter than 100m Less than 0 6A Exceeding 100m shorter than 200m Less than 0 3A Connecting units Max 128 units Transmission method DC power supply superimposed total frame cyclic method Bus form Multi dro
28. eral purpose power supply filter Use it if necessary MI Filter notation in the drawing POWER IN PE OV 24V 24V DC stabilized power supply For details of ANF 01 refer to ANF 01 Products Guide If any of the side by side lines of DP DN 24V and OV exceeds the total length of 50m 2 wire terminal 4 wire terminal 2 14 AnyWireASLINK m Connection example of ASLINK filter ANF 01 for local power supply AnyWireASLINK DP master DNQ POWER IN General purpose power supply filter Use it if necessary IRRE PE OV 24V LI ANF 01 OV 24V OV 24V 24V DC stabilized SLAVE power supply L N FG E d ADP 2 wire 5 terminal L S If any of the side by side lines ER tap 4 wire the total length of 50m DDP H ae 4 wire y UT Soy terminal e 2 wire DP DN terminal D24v of DP DN 24V and OV exceeds I ov terminal 24V DC stabilized General purpose power pp Awe supply filter DDN terminal OE Ee Use it if necessary bie 0 L ov 9 amp H E f bro S POWER IN i MI Filter notation in the drawing i BEE POWERIN a Li RES PE OV 24V OV 24V SLAVE A Br For details of ANF 01 5 refer to ANF 01 Products na Guide A Bac 4 wire lL DP H 24v terminal en AR 0 II Ac B ODP DDN 4 wire NI Lo vy R A terminal g 5 d Set al WU LL ov the total length of 50m D GE terminal If A B of the side by side lines Ik DR Lo of DP DN 2
29. f the connector is forcedly removed when it is hooked the equipment may be damaged When installing check that there is no short circuit due to removal or looseness of element wires and securely tighten the screws on both ends Tightening torque 0 5N m Fixing screw DP DN 24V OV LG AnyWireBus side AnyWireBus transmission line connection part of this unit has easily removable connector terminals Model MSTB2 5 5 STF 5 08AU Manufactured by PHOENIX CONTACT Connectable electric wire 0 2 2 5mm AWG24 12 Tightening torque 0 5 0 6N m Terng Type of signal name yP g Transmission signal side Transmission signal side D 2 N 4V OV Supplies 24V DC stabilized power supply Connected to neutral point of noise filter Ground when there is a malfunction due to 24V based power noise When grounding ground with the functional ground terminal FG of the sequencer at one point Connection of transmission line 4 2 Connect DP and DN with DP and DN of the terminal respectively Refer to the instruction manual of each unit MONITOR connector Connector for connecting maintenance dedicated monitor AN CAUTION Do not connect anything other than the above monitor bg CAUTION Do not send multiple transmission lines DP DN in a multicore cable bundled If sent bundled the equipment will malfunction due to crosstalk DPI yy DP2 DN2 amp The thickness of the transmission line shal
30. for handling I O Read the user s manual of the master unit used and follow the determined procedures Example of description When using interface QJ51AW12AL for Q series sequencer of Mitsubishi Electric Corporation 1 To turn on power for AnyWireASLINK system turn on in the order of 24V DC external supply power for AnyWireASLINK system and power on the sequencer side Turn off the power in the reverse order 2 When the power on the sequencer side is turned on prior to 24V DC external supply power for AnyWireASLINK system transmission circuit drive power voltage drop detection error may occur 3 QJ51AW12AL requires transition time of 1 second until handling of input output data after unit READY Xn0 is turned ON Therefore start a program 1 second after turning ON the unit READY Xn0 ON 1 24V DC external supply power OFF ON 2 Power on the sequencer side OFF ON 3 Unit READY nt OFF 4 Sequence program 1 second or longer Design 3 2 Example of program This program example assigns I O of AnyWireASLINK system to sequencer devices by FROM TO command Example of description When using interface QJ51AW12AL for Q series sequencer of Mitsubishi Electric Corporation X00 X1F UO address YOO Y1F Y20 Y2F QJ51AWA 16 point Equipment Power CPU 12AL output unit Slot 2 4 vacant configuration supply 10 11 13 14 E10 J Ta Ta 3 SET Mi K 10 EST Mi XI xa
31. g direction e 5 ASLINKSENSOR Photoelectric sensor Install it so that light receiving emitting surface is not subject to direct sunlight 2 20 AnyWireASLINK 2 11 2 wire type 4 wire type slave unit There are roughly two types of methods for connection of slave units on AnyWireASLINK One method is the 2 wire non insulation type and the other method is the 4 wire insulation type AnyWireASLINK system employs the power supply superimposition transmission method which superimposes power onto the transmission signals and the connected slave unit can receive not only the transmission signals but also power to operate the slave unit itself and devices on the load side from the transmission signal line and this is basic to this system 2 wire non insulation type slave unit is used to receive not only the transmission signals but also power to operate the slave unit itself and devices on the load side from transmission signal line to control 4 wire insulation type slave unit receives transmission signals and control power for the slave unit itself from the transmission signals and can drive power for operating input output circuit and devices on the load side by local power supply When current capacity on the load side exceeds the upper limit of the transmission line supply current value in AnyWireASLINK system consisting of 2 wire type system or when there is also power supply on the connected s
32. ide use the 4 wire insulation type Any configuration of 2 wire type only 4 wire type only and mixture of 2 wire type and 4 wire type can be used as a combination m AnyWireASLINK slave unit power supply source Control Power for Type load Example of load connected power connected 2 wire non insulation DP DN DP DN Devices for closed circuit such as sensor switch relay LED 4 wire insulation DP DN 24V 0V 0 ae large consumption current load separate power m 2 wire non insulation type 4 wire insulation types and type of terminal ASLINKER Type Cable Kid M12 connector ASLINKTERMINAL ASLINKAMP ASLINKSENSOR type 2 wire non insulation da 4 wire insulation o d o o o JP Legend o With x Without 2 21 AnyWireASLINK m Image of power supply 2 wire non insulation type 4 wire insulation type Power supply to the entire system 24V DC power 2 core cable on which transmission signal and Power suppl power are superimposed pply for load Fe 2 core cable on which transmission signal and power are superimposed HiLocal power supply Power supply for load 2 core cable on which transmission signals and power are superimposed 2 22 Design 3 Design 3 1 Procedures to turn on power and handling of input output data Procedures to turn on power are determined in order to prevent wrong input wrong output
33. inal and 2 wire type terminal This example shows that a main line is 50m or longer in 4 wire transmission line power line Red D Red DP Black DN General purpose power supply filter ASLI tor If the load power consumption is large a four wire isolated terminal can be selected This terminal can correspond to I O of the controller with an Red DP external power supply Two points 2 Black DN J 24V DC oo Dedicated flat cable El 1 25mm four wire 3 8 l 4P link connector is SEE en j een em j i convenient for le re Eight points Black DN The branching CO has no limitation The sum of th portions of DP DN is the total line length 24V DC IT Black DN QQ Red DP AnyWireASLINK terminator BTO One terminator should be connected to the DP DN terminal farthest from the AnyWireASLINK master Connect it correctly so as not to set the wrong polarity 1 Make sure to use a 24V DC stabilized power supply for the power supply to be connected When conforming with UL standards make sure to use an NEC Class2 24V DC stabilized power supply Q i Red DP TD mo points OR de Red DP Black DN Two points Two points a branching by H nn General purpose power supply filter Introduction 8 ASLINK filter When DP DN 24V and OV lines run longer than 50m in total length in the supplying power supply system serially connect
34. k voltage drop of 24V DC external Make adjustments so that power voltage of the 24V supply power DC external supply power does not exceed the rating 21 6 to 27 6V DC Check that the power line is not short Check that the power line 24V OV is not circuited 24V OV disconnected and not short circuited Be careful not to mistake pin assignment when crimping the link connector Check wiring on the terminal block Check that 24V DC external supply power is properly wired to the master unit and the slave unit Also be careful of wiring short circuit improper wiring or insufficient tightening 3 ALM lights up DP DN transmission line disconnection error Check items Description of measures Check that the transmission line DP DN Check connection parts and continuity between is not disconnected lines Check wiring on the terminal block Check that there is no improper wiring Perform address identification operation The AML lights up at the start of continuity Perform address identification operation 4 When LINK does not flash Check error contents by PC diagnosis of the programming tool to take measures LED display part Troubleshooting 6 4 LED state of the slave unit The slave unit also has a status display function by display LED Display status and primary causes are respectively described 1 When LINK lights up The slave unit does not receive transmission signals Transmi
35. l allowable current of 24V OV and COM terminals should be totally up to 1A When this value is exceeded directly connect between terminals by crossover or install another terminal Design 3 4 AnyWire filter If any of the side by side lines of DP DN 24V and OV exceeds the total length of 50m in a power supply system to be supplied serially connect the ASLINK filter Type ANF 01 or filter of COSEL Co Ltd Type EAC 06 472 to 24V and OV in the starting position of the side by side lines This will improve noise resistance reduce the impact of crosstalk by transmission signals and stabilize the signals In any case of power supply to the entire system from the master driving power supply or power supply from the local power supply insert a filter Insert the ANF 01 regardless of installation method and distance when complying with CE Standard m Filter allowable power current Allowable power current ASLINK filter ANF 01 MAX 10A 24V DC Filter of COSEL Co Ltd EAC 06 472 MAX 6A 24V DC 3 7 Design m Connection example of ASLINK filter ANF 01 for power supply to the entire system AnyWireASLINK master Zeg I NS 164 POWER IN General purpose power supply filter Use it if necessary PE OV 240 W Filter notation in the drawing POWER IN PE OV 24V 24V DC stabilized power supply OV 24V SLAVE For details of ANF 01 refer to ANF 01 Products
36. l be 0 75mm or 1 25mm The lower limit of the power voltage shall be 21 6V or more for transmission distance of 200m or less and 24V for transmission distance over 200m e Watch out for voltage drop by cable Voltage drop will cause the equipment to malfunction If the voltage drops significantly supply power on the terminal side Local power supply Do not solder wires connected to the connector terminal The wires may loosen resulting in a contact failure Connection of Transmission Line 4 2 Transmission line building by link connector Branch and removal of equipment can be easily performed by using the AnyWireASLINK system dedicated flat cable and link connector Link connector is a female and male integrated unique crimp type connector and can be coupled with each other using the same configuration And link connector can be crimped to the end of the cable and middle of the cable m Example of branch by link connector Flat cable 4 core Flat cable 4 core I for electric wire diameter of 0 75mm I for electric wire diameter of 1 25mm Flat cable 2 core Flat cable 2 core I for electric wire diameter of 0 75mm I for electric wire diameter of 1 25mm Cabtire cable Flat cable 2 core for electric wire diameter of 0 75mm When cable end is used When the middle of cable is used Refer to How to crimp link connector to flat cable cabtire cable at the end of this manual for details on link connector crimping
37. lectric Corporation MELSEC Q series QJ51AW12AL ASLINKER ts AnyWire transmission line l Slave unit Terminator NE po Introduction Terms This manual uses the following terms in its explanation unless otherwise specified Units of Q series other than CPU unit power unit and input output unit mounted on base unit Unit to control data link system one unit is required for one Master unit system Unit to communicate input output data with master station Engineering tool Generic name of GX Works2 GX Developer GX Works2 GX Developer ff Memory of intelligent function unit to store data such as set Buffer memory value monitor value received from or transmitted to CPU unit ASLINKER Remote 10 2 points of AnyWireASLINK system ASLINKTERMINAL Remote 10 8 points of AnyWireASLINK system ASLINKAMP alg Corporation s sensor amplifier used for AnyWireASLINK ASLINKSENSOR AnyWire Corporation s sensor used for AnyWireASLINK system DP DN Transmission line of AnyWireASLINK power superimposition Intelligent function unit Product name of MELSEC sequencer software package Introduction AN Items to be followed for use 1 Usable cable for transmission signals DP DN General purpose cabtire cables Wire diameter 0 75mm 1 25mm AnyWire dedicated flat cable Wire Number Model Use example diameter cores 3 FK2 125 100 DP DN 1 25mm a e 125 100 DP DN 24V OV 2 FK2 075 100 DP DN e
38. lication detection The master unit of AnyWireASLINK identifies ID address set to the connected slave unit and notifies duplication and non set state as an error am 1 Desmpton 0000H OOFFH ID of output slave unit 0200H 02FFH ID of input slave unit or input output mixing slave unit ALM is also displayed alternately flashes with LINK on the associated slave side Details When the master unit performs automatic address identification operation it detects ID duplication or ID not set slave unit if the unit is connected This function works only when the master unit performs automatic address identification operation When ID duplication and ID not set slave unit is detected slave unit alarm signal X n 1 2 is turned ON Detected error code ID duplicate error 0190H ID not set error 0191H and error ID are stored in the buffer memory Related items ae LJ Hexadecimal Item number Bel 9985 2701H 10112 2780H 10256 2810H Latest error code storage area Note 1 10257 2811H Latest error occurrence ID storage area Note 1 If some errors simultaneously occur a high priority error code is stored Alarm ID information storage area This state can be cleared by turning the power for the AnyWireASLINK system OFF and ON or turning the error flag clear command Yn0 OFF ON and OFF The LINK LED and ALM LED alternately flash on the associated slave unit side This state is kept until the address is chang
39. n Electric shock or malfunction may result To clean or to re tighten the screws on the terminal block and the unit mounting screws make sure to shut off all phases of the external supply power used in the system Unless all phases are shut off electric shock may result Loose tightening of the screws may result in short circuit or malfunction Excessive tightening of the screws may cause damage to the screws or unit resulting in dropping short circuit or malfunction Do not disassemble or remodel each unit Failure malfunction injury or fire may result Make sure to shut off all phases of the external supply power source used in the system for installation and removal of the unit Unless all phases are shut off Failure or malfunction of the unit may result Install and remove the unit base and terminal block 50 times or less after use of the product Compliance with JIS B 3502 If 50 times are exceeded malfunction may result Before touching the unit make sure to touch grounded metal to discharge static electricity charged to the human body Unless static electricity is discharged failure or malfunction of the unit may result Precautions for disposal e Dispose of this product as industrial waste eAbout application of product e When using the sequencer of Mitsubishi Electric Corporation make sure to observe the content regarding About application of product specified by Mitsubishi Electric Corporation If yo
40. nal delay time I system 3 Transmission cycle time i 7 Transmission cycle time I I I l I l 8 a EEE 1 4 Master side processing time 6 Master side processing time I I l Maximum transmission delay ime dem transmission delay time SE I p O r 5 Processing time I I Master unit 5 1 Troubleshooting 6 Troubleshooting 6 1 Visual check Each unit has a state display function with LED and error related to operating state of the unit and communication can be narrowed down by checking this function When any LED displays an error review the setting and wiring to modify 1 Check LED state of master unit 1 Check the RUN LED on the master unit The RUN LED lights up Normal When it does not light up perform the following troubleshooting 2 Check the LINK LED on the master unit The LINK LED flashes Normal When it does not flash perform the following troubleshooting 3 Check the ALM LED on the master unit The ALM LED lights off Normal When it flashes or lights up perform the following troubleshooting 2 Check LED state of the slave unit 1 Check the LINK LED on the slave unit The LINK LED flashes Normal When it does not flash perform the following troubleshooting 2 Check the ALM LED on the slave unit in case of 4 wire type slave unit The ALM LED lights off Normal When it does not light off perf
41. ocessed regardless of the level of skill and describe the method here Please read this manual as an additional reference separate from the Pliers crimping operation which is a general operation method for link connectors described in our technical manual and installation manual 2 Combinations to be covered De em i L emm E em STalls 5 0 Flat cable 100m winding 2 core flat cable AWG16 1 25sq x2 core insulating coating outer diameter 2 5 0 1mm Conductor resistance 2 core flat cable AWG18 0 75sq x2 core insulating coating outer diameter 2 5 0 1mm 0 0270 m Allowable 4 core flat cable AWG16 1 25sq x4 core insulating coating outer diameter 2 5 0 1mm current 5A 4 core flat cable AWG18 0 75sq x4 core insulating coating outer diameter 2 5 0 1mm LP connector For 2 core flat cable 1 25sq Coating outer diameter 2 54mm Cover Black Body Red 10 connectors included For 2 core flat cable 0 7559 Coating outer diameter 2 54mm Cover Black Body Black Crimp type link connector For cabtire cable Coating outer diameter 1 8 to 2 1mm Cover yellow Body Gray Allowable current 5A 2 pole type For cabtire cable Coating outer diameter 1 4 to 1 7mm Cover Pink Body White E ei d i For 4 core flat cable 1 2559 Coating outer diameter d 2 54mm Cover White Body Red Pin protector type Feeler For 4 core flat cable 0 7559 Coating outer diameter 2 54mm Cover Black
42. only J In addition Matters described in IN CAUTION may lead to serious consequences depending on the situation All describe important contents therefore make sure to observe the cautions and warnings Carefully store this Manual so as to access it whenever necessary and deliver this Manual to the end user AN CAUTION e The AnyWireASLINK system has high noise resistance however keep transmission lines and input output cables 100mm or more as a guide away from high voltage cables or power lines A malfunction may result e Incorporate an emergency stop circuit and an interlock circuit for safety into an external circuit other than the AnyWireASLINK system Precautions for design Precautions for installation e Use the sequencer in the environment of the general specifications described in the User s Manual of the CPU unit Use in any environment out of the range of the general specifications may result in electric shock fire malfunction damage or deterioration of the product e Securely insert the protrusion for fixing the unit into the fixing hole of the base unit to mount the master unit for the sequencer using the unit fixing hole as a support point while holding the lever for the mounting unit at the lower part Improperly mounted unit may result in malfunction failure or dropping When using in a heavy vibrating environment tighten the unit with screws Tighten the screws within the specified torque range Loos
43. onnected When connecting wires with terminal blocks do not solder A contact failure may result If power voltage for the remote slave unit becomes insufficient due to a drop in the power supply line voltage connect an external supply power to ensure the specified voltage Do not turn on the 24V DC power source before completing wiring and connections of the whole AnyWireASLINK system Use a 24V DC direct current stabilized power supply for AnyWireASLINK system devices Do not bind the control wire and communication cable with the main circuit or power line or do not bring them close to each other Noise may result in malfunction Make sure to put electric wires and cables to be connected to the unit into ducts or fix them with clamps Unless cables are put into ducts or fixed with clamps drift movement or careless tensioning of a cable may result in damage to the unit or cable and a connection failure of a cable may result in malfunction When removing cables connected to the unit do not hold the cable section by hand when pulling Remove the cable equipped with a connector by holding the connector on the connection part of the unit To remove cables connected to the terminal blocks loosen the terminal screws on the terminal block When cables are pulled while they are connected to the unit malfunction or damage of the unit or cable may result Precautions for startup and maintenance Do not touch the terminals while the power is o
44. orm the following troubleshooting 6 2 Check with buffer memory Example of QJ51AW12AL 1 Check error detail information Error code of the master unit is stored in the latest error code storage area Un G10256 2 Check error ID area Error ID number is stored in the error ID number information UnYG8192 and ID information is stored in the error ID information storage area Un G8193 to Un G8320 3 Check alarm ID area Number of slave units on which error occurs is stored in the alarm ID number information Un G9984 and ID information is stored in the alarm ID information storage area Un G9985 to Un G10112 Troubleshooting 4 Check error detail information of the slave unit Error contents of the slave unit are stored in the status details Un G12327 of the parameter storage area Refer to the QJ51AW12AL user s manual for details 6 3 LED state of master unit 1 When RUN LED does not light up even when power is supplied Check items Description of measures Check unit mounting and connection state Remove the unit and mount and connect it again Check internal consumption current of the Re consider system configuration and limit the entire system internal consumption current below the rated outpu current of the power unit Refer to the following manual for how to calculate consumption current of the system User s manual of the CPU unit used Hardware design maintenance and inspection edition
45. owever it is necessary that number of units in which total of DP DN consumption current of connected slave units is in a range of allowable supply current and number of occupied input output respective points of slave units is the number of units in a range of transmission points set by the master 5 Voltage drop reference When transmitting transmission signals and power as a batch observe the following formula in consideration of voltage drop R Q x 2 x L m x I A lt 2 4 V R Wire resistance L Length of longest wire l Required current Wire resistance 0 75mm7 0 025Q m Wire resistance 1 25mm 0 015Q m If the voltage is deviated from this condition provide local power supply Introduction 6 Wiring mode of transmission line Use 1 cable for 1 unit in the AnyWireASLINK master and do not bundle multiple transmission lines in a multi core cable AnyWire transmission has a high noise resistance however it is recommended to install transmission lines away from a noise source such as an inverter power line wherever possible in order to ensure a more stable transmission quality Any of multi drop method T branch method and star type branch method is allowed Multi drop method No branch T branch method Branch 1 Branch 1 Star type branch method Branch 2 Branch 3 Introduction 7 Transmission line configuration This connection example is a mixture of a 4 wire type term
46. p method T branch method tree branch Connection mode method etc Transmission protocol AnyWireASLINK protocol Double check checksum Up to 512 points Input 256 points output 256 points IO points Transmission line disconnection detection function transmission RAS functions line short circuit detection function transmission circuit drive power drop detection function ID address redundant non setting detection function General purpose 2 wire 4 wire cable VCTF VCT 0 75 to 1 25mm rated temperature 70 C Electric wire used General purpose electric wire 0 75 to 1 25mm rated temperature 70 C Dedicated flat cable 0 75mm 1 25mm rated temperature 90 C Circuit Supplied from a sequencer bus side Voltage 5 V 5 Current 0 2 A max Transmission line driver Supplied to a front panel terminal Master power supply Voltage 24 V DC 15 to 10 21 6 to 27 6 V DC Ripple 0 5 V p p max Current 0 1 A when 128 slave units are connected not including load current Voltage 24 V DC 15 to 10 21 6 to 27 6 V DC Ripple Bridge power 0 5 V p p max Gateway power Current 0 1 A when 128 slave units are connected not including load current 1 This varies with the AnyWireASLINK master unit Refer to the user s manual for specification details AnyWireASLINK 2 2 3 Cycle time 64 points 128 points 256 points Input 32 points Input 64 points Input 128 points Input 256 points Output 32
47. points Output 64 points Output 128 points Output 256 points Transmission cycle time Transmission cycle time is the time to update input and output data of the master unit and all slave units In actuality transmission delay time twice of transmission cycle time is generated by influence of the double check function 512 points Transmission I O point number Transmission cycle time is a value between one cycle time and two cycle time In order to securely make input signal respond issue an input signal longer than two cycle time Setting range of transmission frame varies with the master unit Refer to the user s manual of each master unit for details Transmission speed of the AnyWireASLINK system is fixed 2 2 4 RAS functions Transmission line disconnection detection function Transmission line short circuit detection function Transmission circuit drive power drop detection function ID address redundant non setting detection function When there is no response from slave of ID memorized on the master unit side the master unit detects this and notifies an error and at the same time lights up the master unit side ALM lamp When the transmission line is short circuited the master detects this and immediately stops transmission and notifies an error and at the same time lights up the master unit side ALM lamp When voltage of 24V DC power supplied to the master unit drops th
48. power supply and a method to drive them by batch power supply And when driving them by batch power supply this system allows the transmission line and power line to be wired as a bundle in a 4 core cable When a 4 core cable is used wire diameter and distance of the power line should be the same as those of the transmission line Prevent supply voltage to the slave unit from dropping below the lower limit of the allowable voltage range 21 6V Design Example of description When using interface QJ51AW12AL for Q series sequencer of Mitsubishi Electric Corporation m Concept of capacity for batch power supply and local power supply Description of power supply Cable used Master side power supply 0 1A 24V DC Slave total load current for drive circuit Batch power 24V DC 4 wire cable supply F Dedicated flat cable Total external load current 24V DC 100 AC etc Master side power supply 0 1A 24V DC 2 wire cable power supply Slave total load current for drive circuit supply SE 2 wire cable power supply Local power Total external load current 24V DC 100 AC etc Design m Example of batch power supply JI H KE u ay m Example of local power supply a e JI 24V 24V e ZH BE Signals on the terminal block are as follows D Signal transmission line G Signal transmission line 24V Connect 24V of 24V DC stabilized power OV Connect OV of 24V DC st
49. r a FK4 075 100 DP DN 24V OV The above cables can be used Basically use unshielded cable 2 Transmission line and power suppl Transmits transmission signals DP DN only Use 2 core cables Transmits transmission signals DP DN terminal and DC power supply 24V OV for connection load drive as a batch Use 4 core cables Any of the above methods is allowed Use a stabilized power supply for 24V DC Provide a power supply unit dedicated for AnyWire or provide a line to directly feed power from power supply terminal When conforming with UL standards make sure to use an NEC Class2 24V DC stabilized power supply Voltage fed to all AnyWire devices should be within a range of 21 6V 27 6V Introduction 3 Transmission distance wire diameter and allowable supply current This system transmits by power superimposition method DP DN allowable supply current varies depending on wire diameter and total extension used therefore use wires within a range shown in the table DP DN allowabl Wire diameter Transmission distance ee supply current BZ Shorter than 50m Less than 2A 1 25mm 0 75mm Consider transmission distance on the basis of total extension total cable length including branch Cable length coming out from the unit is included in total extension Total extension means total of cable length used for transmission line 4 Connecting units Max 128 units H
50. r side AnyWireASLINK 2 7 Monitoring function The slave units of the AnyWireASLINK have their own ID addresses and a slave unit which has an ID address sent from AnyWireASLINK master unit responds to the ID address so that it detects for disconnection and checks for existence of a connected slave unit The AnyWireASLINK master unit stores an address of the slave unit which is connected at that time by the automatic address identification operation into EEPROM This information is stored even if the power is turned off 2 8 Automatic address identification operation This operation is intended to use the DP DN disconnection function correctly Make sure to perform this operation when starting up the system for the first time and after changing the system configuration of AnyWireASLINK To perform automatic address identification there are methods to hold the SET button on the master unit body and issue automatic address identification command output Refer to each user s manual for details CAUTION This operation is not intended to transmit I O data I O data is transmitted when the power is turned on regardless of this operation For a slave unit which is still in a connection state at the time of disconnection I O data is continuously transmitted When any error occurs during operation do not perform automatic address identification operation Disconnection information will be lost AnyWireASLINK 2 9 1D dup
51. requency power line take measures for noise such as shielding with a conductor plate JN caution Transmission cable Be careful to prevent the voltage from lowering below the lower limit of the allowable voltage range due to voltage drop by cable Lowering below the lower limit may result in malfunction If there is a large voltage drop install a local power supply Do not connect soldered wires directly to the terminal The wire may loosen resulting in a contact failure m Reference example of electric wire 300V vinyl cabtire cable VCTF Dedicated flat cable HKV Model FK4 075 100 100m winding Dedicated flat cable HKV Model FK4 125 100 100m winding 2 4 4 Transmission line supply current value AnyWireASLINK JIS C3306 Cross section area 0 75mm Allowable current 7A 30 C Conductor resistance 25 10Q km 20 C or less Insulation resistance 5SMQ km 20 C or more Cross section area 0 75 mm Allowable current 5A Maximum conductor resistance 250 km Cross section area 1 25 mm Allowable current 5A Maximum conductor resistance 15Q km AnyWireASLINK system is allowed to be established with two wires Not only transmission signals but also power for the slave unit and on the load side connected thereto are superimposed on these two wires Allowable supply current transmission line supply current value from transmission line varies depending on wire diameter and total wiring dis
52. rities DP DN so connect it correctly 1 2 Temporary operation when turning on power for the first time The master unit is classified for operation on the sequence QJ51AW12AL is classified as Q Bus intelligent function unit For use of QJ51AW12AL check that I O unit intelligent function unit switch setting on the sequencer side is correctly set Follow the power on procedures and after turning on the external supply power and turning on the power for the sequencer body handle data by FROM TO and automatic refresh function Check the following See P 6 3 QJ51AW12AL display RUN lights up LINK flashes SET lights off ALM lights up Each slave unit LINK flashes ALM lights off Terminator polar Display LED lights up low intensity Automatic address identification operation See P 2 20 Hold the SET switch of QJ51AW12AL and release when the SET LED lights up When the SET LED lights off automatic address identification operation is completed Even if this operation is not performed I O is transmitted Quick Start 5 I O check Check whether there is any difference in correspondence of mapping between I O of the slave unit and UO of the sequencer When I O is handled improper input improper output may occur therefore observe the following power sequence 5 1 QJ51AW12AL requires transition time of one second up to input output data handling after turning on power for
53. s described in AnyWire refer to total extension of a cable Total length is the total cable length to be used including branches Wiring of AnyWireASLINK system can be established by only 2 transmission lines DP DN 2 transmission lines DP DN address maximum 200m in total extension See P 2 2 This total extension also includes the length of the cable coming out of the slave unit e In case of basic type Master unit L lt Set transmission distance Total extension Terminator Slave unit e In case of branch Master unit FE Li L2 L3 L4 lt Set transmission distance Total extension L2 EZ ES i EZ Terminator l gt H E Slave unit AnyWireASLINK 2 4 3 Transmission cable type and precautions General purpose cabtire cables twist pair cables and specifically made flat cables etc can be used for transmission cable Use the following electric wires General purpose 2 wire 4 wire cable VCTF VCT 0 75 to 1 25mm rated temperature 60 C General purpose electric wire 0 75 to 1 25mm rated temperature 60 C Dedicated flat cable 0 75 mm 1 25mm rated temperature 70 C Nc AUTION Shield cable Do not use shield cable because this system employs the power superimposition transmission method When a strong noise source is laid in the periphery of the transmission line in such a case that the transmission line runs along with an inverter output line servo output line and high f
54. s of the connector cover securely engage with the connector body holes Before swaging After swaging For 4 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 0 7550 For 2 core electric wire diameter of 1 25sq 3 3 6 Now crimping is completed It is not allowed to disassemble the connector after crimping and re use it at the time of failure and layout change etc For 4 core electric wire diameter of 1 25sq For 4 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 0 75sq For 2 core electric wire diameter of 1 25sq lt bh 5 Crimp to cabtire cable end Signal assignment for cabtire cable is the same as that for flat cable See the table in page 2 1 1 After peeling the coating at the cable end place a cabtire cable on a connector cover and close the connector cover Check that the hooks have entered the grooves without deviating Small hook Black Ba GE N 2 Check that the cable end face is not deviated from the connector cover and the small hook engages 3 Insert a connector body into the connector body of 2 Four electric poles rising from the connector body enter four holes of the connector cover Ee Large hook Connector body hole I Connector body 4 1 4 Swage in the state of 3 with a dedicated tool LP TOOL In that case check that the snapping sound is heard and four large hooks of the conne
55. ssion waveform error If normal voltage of approximately 17V to 18V is observed when measurement is made between transmission lines DP DN in DC mode of a tester When the measured voltage is the same as the power voltage check that there is no improper wiring of the transmission line Also check that there is no error in the master unit 2 When LINK lights off The slave unit does not receive transmission signals Transmission signal disconnection error Check that there is no contact failure such as looseness on the connections parts of the transmission line DP DN Check that power is supplied to the master unit Check that the transmission signals reach the terminal of the transmission line DP DN If normal voltage of approximately 17V to 18V is observed in DC mode of a tester When the transmission line is disconnected etc the position can also be identified by difference in LINK display of the terminal Example ish Lights off Lights off Failure location 3 When ALM lights up The I O side of the output slave unit is short circuited so eliminate the failure The display is automatically returned 4 When ALM flashes The signal voltage of the transmission line DP DN is low Check that the master unit supply voltage of the system is within the allowable voltage range Check that the connection unit and load capacity are appropriate for total extension of the transmission line and allowable supply
56. tance therefore it is necessary that the total of consumption current of DP DN connected consumption current of slave unit itself consumption current on load side connected to 2 wire slave does not exceed this allowable current value m Transmission line supply current value Wire diameter of transmission line DP DN Length of transmission line Total extension shorter than 50m MAX 2 0A MAX 1 2A Total extension 50 100m MAX 1 0A MAX 0 6A Total extension 100 200m MAX 0 5A MAX 0 3A AnyWireASLINK 2 4 5 Terminator 2 12 This unit incorporates a circuit which shapes a transmission waveform inside and functions to reduce a situation where the transmission waveform is disturbed depending on an external environment Properly connect to the transmission line because it has a polarity D Red G Black Reverse connection may result in transmission failure The line extended from the master unit line wired to the very end is called a trunk line and the line wired branched from the trunk line is called a stay line A terminator for 1 master unit must be connected at the very end of the trunk line When extending stay lines branched from the trunk line if the length of the stay lines is more than 40m one terminator must be connected at the end of the stay line It is possible to omit terminators if the length of the stay line of the transmission line is less than 40m however it is recommended to connect a terminator
57. the sequencer body Therefore do not perform access related to this unit X Y FROM TO etc for two seconds after turning on power for the sequencer See P 3 1 5 2 Follow the power on procedures for the sequencer and turn on power in the order of external supply power and power for sequencer body See P 3 1 5 3 Depending on how to supply from external supply power transmission power voltage drop error Xn3 may occur and DP DN disconnection error Xn4 may be on and then ALM may occur at the time of initialization See P 1 3 Full operation If there is no problem with temporary operation move to full operation AnyWireASLINK 2 AnyWireASLINK 2 1 Features AnyWireASLINK system is a Sho Haisen wiring saving system equipped with small and fewer point multi distribution units suitable for wiring saving on sensor level This system covers bundling of minimum 1 point to 8 points in a compact unit therefore it can bundle even in a narrow device in which BOX is not placed In addition Digital Link Sensor in which sensing function and wiring saving function are incorporated is proposed This sensor can be directly connected to transmission line and offers ultimate wiring saving which uses no remote terminal And not only ON OFF information but also information such as sensing level and disconnection are transmitted to the controller side It is possible to monitor the operating state prev
58. to long stay lines of the system AT ee eiee Master unit Basic type Terminator One branch stay line 4 gt less than 40m Terminator It is allowed to omit terminator Stay line 40m or less Slave unit Master unit Terminator FT Two branches stay line 40m or longer Terminator Stay line 40m or less AnyWireASLINK system allows up to three terminators to be connected AnyWireASLINK 2 5 AnyWire filter If any of the side by side lines of DP DN 24V and OV exceeds the total length of 50m in a power supply system to be supplied serially connect the ASLINK filter Type ANF 01 or filter of COSEL Co Ltd Type EAC 06 472 to 24V and OV in the starting position of the side by side lines This will improve noise resistance reduce the impact of crosstalk by transmission signals and stabilize the signals In any case of power supply to the entire system from the master driving power supply or power supply from the local power supply insert a filter Insert the ANF 01 regardless of installation method and distance when complying with CE Standards m Filter allowable power current Allowable power current ASLINK filter ANF 01 MAX 10A 24V DC Filter of COSEL Co Ltd EAC 06 472 MAX 6A 24V DC 2 13 AnyWireASLINK m Connection example of ASLINK filter ANF 01 for power supply to the entire system AnyWireASLINK master Gen
59. u have any questions regarding the sequencer make sure to contact the service department of Mitsubishi Electric Corporation Contents 1 MERK START EE 1 1 1 1 INSTALLATION Ge ee ee ee een 1 1 1 2 TEMPORARY OPERATION WHEN TURNING ON POWER FOR THE FIRST TIME 2 1 3 FULLOPERATION rv 1 3 ANYWIREASEINK er 2 1 0 FEATURES EE 2 1 22 SPECIFICATIONS ve 2 1 2 2 1 General specifications rrrrrrrnrrnnnrrnnnrrnnnrnnnrrnnnrrnnernnnennnnennnnennnernrnernnnernnneneneennneseneennn 2 1 2 2 2 Performance spechficatons 2 2 223 GENE N E ee E E TAO 2 3 2 24 RAS ne e E 2 3 2 3 PRAT UNE 2 4 2 3 1 System configuration 2 4 23 2 Types of master Unit hr 2 4 2 3 3 Types of slave uni 2 4 2 3 4 Number of slave units conneched 2 5 2 3 5 Connection of slave unt 2 5 2 4 TRANSMISSION LINE DP DN ms dedesdensed endre dene 2 6 241 Cena 2 6 242 Transmission Re E e 2 9 2 4 3 Transmission cable type and precautons 2 10 2 4 4 Transmission line supply current value 2 11 225 KN un e E 2 12 2 5 ANYWIRE FILTER vr 2 13 2 6 ADDRESS SETTING REFERENCE essensseeseeesseesseressressrrsssessrrssereseressresseressresseroseressrrsseees 2 16 2 7 MONITORING FUNCTION ae 2 17 2 8 AUTOMATIC ADDRESS IDENTIFICATION OPERATION 217 29 DPLU ONDE TINN rene 2 18 2 10 INSTALLATION OF DEVICES see 219 2 11 2 WIRE TYPE 4 WIRE TYPE SLAVE UNITA 2 21 DE SION EE 3 1 3 1 PROCEDURES TO TURN ON POWER AND HANDLING OF INPU
60. undant or not set LED indication BL296 _ B O8F 20 BL29601B 08F0 4 20 BL2960B 08F0 BL296018 08F8 20 BL296 1B 08F 3 BL29601B 08F0 1 1 LED indication unit LED indication unit LED indication unit mm hl Ep He 2 sfefmfrefwuig BL296PB 08RS BL264PB 16F T5 LED indication unit LED indication unit Troubleshooting ASLINKIAMP fiber e mrd Indication status Detailed status weg No transmission wave B289SB 01AF CAM20 8 En B2895B 01AF CAS Flashing r Prag B289SB 0 1 AF CAM20 V DP DN disconnected or no power supply i PERS TEEN o Sensing level reduced Green Fed Flashing Transmission signal level reduced LED indication Alternate flashing Master unit detecting the unit ID 13 LED indication unit address redundant or not set e Jon eo DI lo s ASLINKAMP photoelectric proximity Indication status Detailed status B289SB 01AP CAM20 B289SB 01AK CAM20 B289SB 01AP CAS B289SB 01AK CAS Green g zw DP DN disconnected or no power supply Sensing level reduced Red Flashing 4 Transmission signal level reduced of ee Normal LINK Alternate flashin Master unit detecting the unit ID ALM LINK address redundant or not set AM gt yo o Fe eg ii ee E 2 w We 5 ei m 6 7 Troubleshooting sASLINKISENSOR Photoelectric type 1 B283SB PC SET is a set model of B283SB 01 1KP and B283SB 01 1KC Indication status Detailed status B283SB 01