1. 2 Fuse 3 Power switch 4 Voltage setting switch 115 230 VAC 5 Signal slot for connecting with a balance 4 START UP e On plugging the balance to mains instrument s diode ON LOAD located on terminal s housing is lit up e Press powering key located on the upper left section of terminal s overlay Within a few seconds the OS Windows CE and RADWAG software start loading which is signaled by flickering red diode ON LOAD e On completing the startup procedure the instrument s displays main window of the balance software in working mode Mass control e Next switch on the power on the automatic feeder using the dedicated power switch If the system is connected properly then it is ready for operation 11 An example of a workstation for controlling mass with connected label printer 5 AUTOMATIC FEEDER CONTROLS Button Description Diode confirming powering the automatic feeder oe Diode indicating an error of the automatic feeder 6 MASS CONTROL MODE lt Mass control mode enables controlling mass of objects automatically dispensed by the automatic feeder PA 02 H onto a pan of a connected balance The mode allows for automatic checking a complete product batch on determining its quantitv 6 1 Working mode activating procedure Procedure e Select lt Mass control mode the software automatically returns to the main window and displavs pictogram in the upper bar e Automatica
2. N 2 1 Unpacking and leveling of the PA 02 H On unpacking the automatic feeder PA 02 H series and removing the transport protections place the automatic feeder on a stable foundation possiblv an anti vibration table Then screw the chute trough using two nuts as indicated on below figure CAUTION while removing the automatic feeder from the box and its relocating always hold the device by its bottom part as the top section is not permanentiv fixed to the feeder s housing When the automatic feeder is fullv assembled connect all cables supplied with the device the power and signal cables On connecting all cables level the feeder bv screwing the adjustable feet and monitoring the status of level indicator located under the feeder s top cover level is visible through a small opening in the cover 2 2 Cleaning The cleaning procedure refers to cleaning the dispenser and its troughs CAUTION Cleaning the trav of the automatic feeder if assembled mav cause its damaging Follow below procedure to correctly clean to automatic feeder s dispenser e Remove the top lid of the automatic feeder e Unscrew 4 bolts fixing the dispenser to the automatic feeder hexagon bolts Disassemble the automatic feeder s dispenser Clean disinfect the dispenser After cleaning assembly the dispenser in the automatic feeder When assembled fix the dispenser using the 4 hexagon bolts Assembly the top lid of the automatic feeder
3. Top lid of the automatic feeder A bolt fixing the dispenser Dispenser of the automatic feeder A dispenser disassembling from the automatic feeder 2 3 Plugging to mains The automatic feeder PA 02 H series is powered from mains 230V with use of a power cable supplied with the feeder Plug power cable to mains plug the power adapter s plug to feeder s socket located at the back of the housing and switch on the feeder using the main power switch 2 4 Connecting automatic feeder to a balance Connect the automatic feeder to a balance using a supplied cable Connect the cable to balance s COM2 port socket no 4 see figure below Description of slots and interfaces of a balance terminal 1 Ethernet slot RJ45 4 IN OUT slot RS232 COM2 2 RS232 interface COM1 3 USB port Parameter settings for communicating the automatic feeder with a balance Enter group of parameters lt Devices gt and set the parameters for connecting the automatic feeder E ep oe TA CAUTION The data on address and baud rate are specified on feeder s data plate located at the feeder s housing COM 2 port settings in a balance Enter group of parameters lt Communication gt and set the transmission parameters for port COM 2 Ton 5 fap mar To 7 Taw ome p 3 AUTOMATIC FEEDER STRUCTURE 3 1 Dimensions 3 2 PA 02 H sockets and switches 1 Power supply socket
4. User manual Automatic feeder PA 02 H User manual no ITKU 70 04 02 13 A BALANCES AND SCALES RADWAG 26 600 Radom Bracka 28 POLAND Phone 48 0 48 38 48 800 fax 48 0 48 385 00 10 export radwag com www radwag com FEBRUARY 2013 Table of contents i BASIC INFORMATION d a MT 4 1 1 intended Use nasse ei su een 4 1 2 Rrecauti nary measures 4 1 3 Waran Conditions een 5 1 4 The manuais SiON MM cancer Re see 5 2 UNPACKING AND INSTALLATION na I 6 2 1 Unpacking and leveling of the 02 n rna rna nnnmnnn 6 2 2 Gleann a aa aa AN 7 2 3 LOGIN B ei A A 8 2 4 Connecting automatic feeder to a 8 3 AUTOMATIC FEEDER STRUCTURE N 10 ae a ian 10 3 2 PA 02 A sockels Switthes ann 1 A STAR UP Esel 11 5 AUTOMATIC FEEDER CONTROL Si 12 6 MASS CONTROL i i a Na 13 6 1 Working mode activating nterne 13 6 2 Mass conirol lobal i iii iii a 13 6 3 Databases Mass control 14 COMMON processi se iii eee E 15 TIDATABA SE ere tare d 17 1 BASIC INFORMATION 1 1 Intended use Automatic fe
5. date Date of control end 9 User A user carrying out the control amp Product A controlled product ll Average Average mass determined from carried out control process Standard deviation from carried out kulu Standard deviation control process Error 2 Control error 2 Error T1 Control error T1 Error T1 Control error T1 Error T2 Control error T2 Quantity of a controlled batch determined in a report Batch quantity Each report can be printed on its entrv and displaving its details The upper bar contains a pictogram lt Print gt which pressing causes printing the report on a printer connected to balance s terminal Additionally the complete database can be exported to an external file by pressing a button lt Export to file gt located in the upper bar 6 4 Mass control process Before starting the mass control process carrv out the following steps Set batch quantitv for a carried out mass control process touch grev coloured workspace on balance s displav to open a window Gon cotti and select group lt Settings gt Next select option lt 72 Batch quantity gt for entering quantity of controlled units in a current automatic mass control process Accept entered value by pressing ia kev Set lt EZ Low limit below the value of the smallest lightest controlled part Set the limit value so that it protects against saving in a final report mass of a value below the lightest
6. eder PA 02 H series is intended to automatic dosing feeding of parts and objects having small dimensions in particular pills and capsules and also small mechanical components The PA 02 H if connected to a balance ensures even feeding of the dosed objects onto a weighing pan of the balance A svstem comprising an automatic feeder and a RADWAG balance 3V series enables fast and precise carrving out of statistical control of samples in accordance with strict pharmaceutical requirements 1 2 Precautionary measures A Before first use of the automatic feeder it is highly recommended to carefully read the attached User Manual and operate the device as intended Before putting in use remember to level the automatic feeder After leveling lock the adjustable feet of the PA 02 H to prevent its displacement A system including an automatic feeder and a balance should be placed on an anti vibration table Fillthe automatic feeder by pouring the parts centrally in the center of the automatic feeder s opening In case of defect immediately unplug the device from mains G Devices to be decommissioned should be decommissioned in accordance to valid legal regulations Do not use the automatic feeder is areas endangered with explosion The automatic feeder PA 02 H series is not designed to operate in EX zones 1 3 Warrantv conditions A RADWAG feels obliged to repair or exchange all elements that appear to be faultv bv p
7. i Mass controls A Ambient conditions ey Packages I Warehouses amp Printouts 5 Universal variables In order to enter the MP Database gt menu when in the main window of the terminal press key and select option P Databases gt from the available menu Operation on databases and balance operation is described in details in a user manual of a balance connectable to the automatic feeder PA 02 H series MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG BALANCES AND SCALES POLAND 26 600 Radom Bracka 28 Phone 48 48 38 48 800 fax 48 48 385 00 10 export radwag com www radwag com
8. item of the controlled batch e g a half of a pill Set lt High limit gt value Set the limit value so that it protects against saving in a final report mass of a value exceeding the heaviest item of a controlled batch e g if two pills are simultaneously dispensed onto a weighing pan In such case the software skips the measurements and continues mass controlling process Set e Dosing power gt parameter defined in and ranging from 0 to 100 The dosing power is a parameter determined separately for each controlled product Setting e Dosing power gt parameter is carried out by pressing SETUP button entering A Databases and the database of lt Products gt Then select a product entry in the database and set required Dosing power for the product to be dispensed Select a product to be controlled from the database of products lt gt The product entrv must have the following parameters determined nominal mass Mass limits for errors negative lt T1 gt Min and positive lt T1 gt Max The error values are determined in of nominal mass value The errors lt T2 gt and lt T2 gt are not to be determined by a user The software sets their values as doubled value of errors lt 1 gt and lt T1 gt Select a product to be controlled from the database of products 9 Course of a Mass Control process On selecting all applicable settings press key to start automatic mass control proce
9. lly an on screen button is available in the bottom bar of the displav Vf Start mass control process 6 2 Mass control global settings Entering the mode settings Is carried out by pressing the grey coloured Cr workspace and selecting an group of parameters named Settings Em which contains the following Request batch The function orders requesting a batch number before ii number starting mass control process Determines quantity of a batch i e number of product BBE Batch quantity units to be controlled _ PRINT Leim A value exceeding which causes accepting a measurement record by a balance A value exceeding which causes omitting a gt limit measurement in the summary e g if two parts pills 9 are simultaneously dispensed on balance s weighing pan A parameter enabling for switching on off automatic SI p printout of a report on completing mass control process A parameter enabling selecting whether on completing Printout the control process the balance should trigger a standard or a non standard printout 13 6 3 Databases Mass control records In the working mode lt Mass control and in its databases there is a new database item added lt Mass control which contains reports from completed mass control processes report from mass control contains the following information Batch number Number of a batch under control Start date Date of control start EJ End
10. roduction or their construction B Defining defects of unclear origin defects and means of their elimination can oniv be realized with assistance of manufacturer and user representatives C RADWAG does not bear anv responsibilitv for defects losses or accidents resulting from unauthorized or inadequate performing of production or service processes D Warranty does not cover Mechanical defects caused by product exploitation other than intended defects of thermal and chemical origin defects caused by lightning overvoltage in the power network or other random event Automatic feeder defects if it is utilized contrary to its intended use Mechanical defects or defects caused by media water liquids and natural wear Automatic feeder defects caused by inappropriate setting of a defect of electric power network Maintenance activities cleaning E Loss of warranty takes place if A repair is carried out outside RADWAG sales office or authorized service point Service claims intrusion into mechanical or electronic construction by unauthorized people The device is connected contrary to its intended use F Detailed warranty conditions are listed on a service card 1 4 The manual s significance lt is very important to read the user manual carefully before switching on and Starting up the automatic feeder operation even if the user is experienced and has worked with the this type of devices 2 UNPACKING AND INSTALLATIO
11. ss The mass control process is started automaticallv the balance is automaticallv tarred and the feeder starts dispensing the first element onto balance s weighing pan On dispensing the first element onto balance s weighing pan the feeder is stopped and the dispensed item is weighed The first stable measurement result is saved On saving a measurement result the mass indication on balance s displav is zeroed and the automatic feeder is restarted to dispense the following product onto balance s weighing pan As the following product is dispensed onto the weighing pan the weighing process starts The procedure is repeated the same way as in case of the first dosed element The cycle is repeated until checking weighing all of declared pieces in a process During control process balance s display shows on an ongoing basis basic parameters on the carried out control i e set standard quantity Product Average Standard deviation Number of errors T1 Number of errors T1 All reports from completed mass control processes are stored in the database lt Mass controls gt Each control process can be aborted at an optional moment by pressing x key on balance s display On pressing the process is stopped and the control is cancelled no report is generated for an aborted control 7 DATABASES Balance s software features the following databases Products al Weighing records Clients m