Contents

1. 24 AS CcINCUIMC s 2 ac ate inoate O1 EL 17127 10 205 1 T ITELTTTT 24 U2 Battery coe II KM PEN IEEE Se RE AU 24 79 WIGINCCNANCE uses nn db REATUS ARA S RULES ma ET EE E onsen 6 25 LA e o APP TANAURBE REESE ERE USE DER RE Jia 26 8 Technicalspecifications 27 AS UI 27 8 2 Installation options of the charger IP4I IP67 oooooooooooooo o 28 OZ O e IR ue o II O 28 a Y a ee ee E Ba O e 28 Y BAspOSalos 5 422299222 94 5 939 2254597 Se eee EES ee RI JR eens cus 29 10 Service schedul6G 4444444444444 44 4 rre 30 I Purpose and application Il Manufacturer Invacare EC Hong A S Ostergade 3 DK 4270 Heng Tel 45 58 85 27 22 Fax 45 58 85 43 86 2 Purpose and application Purpose Robin is a ceiling mounted hoist meeting the requirements for hospitals housing for the elderly institutions and private homes Robin is intended for moving clients weighing a maximum of 200 kg including clothing hoist sling and other accessories The hoist is designed for indoor use in normal temperatures and humidity If you wish to use the hoist in any other environment contact Invacare for advice and instructions Use of the hoist for purposes other than transfer of people is not advised and is undertaken at ones own risk Conditions It is a condition of sale that the purchaser of the ceiling hoist must receive training from Invacare personnel or an authoris
2. Connection for O emergency battery Indicator light Hand control 8 Lifting straps Retainer for 8 P hand control accessory Emergency stop lowering strap Strap hooks FUNCTIONS ON THE UPPER SIDE Suspension pin for connecting the hoist to the hoist trolley 2 Finger screw for dismounting the top section 3 2 Operation Up Down Hand control and indicator light Robin is activated when the hand control buttons are pressed The blue indicator light illuminates when Robin is in use and turns off automatically after approx 30 seconds The hoist is lifted and lowered by operating the hand control The control buttons on the underside of the hoist may also be used for this purpose The control buttons work independently of the hand control Note The buttons must be depressed in the middle in order to ensure correct function which is best obtained as shown in the pictures The hoist will automatically run at high speed upwards as well as downwards when it is not loaded The straps must be straight to ensure that they feeds into the apertures correctly The straps are held taught by the weight of the hooks therefore the lifting straps should be freely suspended when the unloaded hoist is running upwards and downwards When the hoist is loaded with a weight of more than 10 kg the speed will automatically be lowered to a safe level when moving in both directions Robin has a built in soft start ens
3. Robin should be stored in a dry place under conditions mentioned in section 5 2 Transport Pull the emergency strap before the Robin is stored to avoid unwanted activation of the Robin and furthermore to protect the battery from damage when the hoist is stored for a longer period without being used If the emergency strap is not pulled the capacity of the battery will deplete completely and will be irreparably damaged When the emergency strap is pulled during storage it will be possible to regain the entire capacity of the battery by exercising the battery see section 3 6 Battery maintanance 6 3 Maintenance performed by owner Check the lifting straps on a regular basis If there are signs of damage in any way do not use the hoist Contact your local Invacare dealer for advice The straps must only be replaced by persons authorised by Invacare 23 7 Service amp lifetime 7 1 Service amp lifetime To ensure the optimal function and safety of Robin it is important to perform service and maintenance in accordance with the manual Maintenance must be carried out following national regulations and at least yearly According to the Factories Inspectorate regulations Robin has to undergo an annual service by an Invacare authorised person Durability and lifetime expectancy is based on an annual service programme performed by an Invacare authorised dealer or Invacare Robin has an expected lifetime of approx
4. Invacare Robin User s Manual Quality Declaration Congratulations with your new hoist Invacare Robin from Invacare EC Hong A S Your new hoist is C marked in accordance with directive 93 42 EEC concerning medical devices Invacare Robin is developed and constructed with consideration for the user and others handling or assisting with lifting Furthermore the hoist is developed in accordance with the European Standard EN 10535 Invacare Robin is supervised and quality controlled throughout the entire production process and the finished hoist is inspected by our finished goods control Identification label and QA mark are located on the hoist confirming that the finished goods control has approved the hoist Please read the entire user s manual before using the hoist Invacare EC Hong A S is certified according to ISO 9001 and ISO 13485 For and on behalf of Invacare EC Hong A S Puesto od Be Ren Engskov Carsten Borup Managing Director Technical Manager DK KVALITETSDEKLARATION Tillykke med Deres nye personlefter Invacare Robin fra Invacare EC Hang A S Deres nye personlofter er CE market og lever op til alle krav i henhold til direktiv 93 42 EWF om medicinske anordninger Personlofteren er udviklet og konstrueret under st rst mulig hensyntagen til brugeren samt alle andre der enten h ndterer personlefteren eller hj lper til ved lofteren Invacare Robin er udviklet under hensyn
5. The product should be reused where possible 27 8 2 Installation options of the charger IP41 IP67 8 2 1 IPAI May not be used in a wetroom environment 8 2 2 IP67 The charger is designed according to IP67 and can therefore be used in wet locations according to these illustrations Bath tub Shower basin gura m a M MNT E URN j f j f f i E Shower without basin A ica f X Shower head IIS j Zone 1 2 Q Fx de D Zone 2 b gt Ux E Zone 3 Y d Shower with fixed partition p Shower head f f Zone j j u gt f Zone Ly Mila T d SD Installation of the charger is recommended in zone 2 and 3 28 9 Disposal This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 CE This product may contain substances that could be harmful to the environment if disposed of in places landfills that are not appropriate according to legislation The crossed out wheelie bin symbol is placed on this product to encourage you to recycle wherever possible Please be environmentally responsible and recycle this product through your recycling facility at its end of life All electrical parts must be removed and disposed of as electrical components Plastic parts must be recycled or incinerated Steel and aluminium parts must be disposed of as metal scrap Batt
6. Check hand control for damage and function Make sure that the hand control is connected correctly Check emergency stop and emergency lowering 30 Yes you can Customer Sales and Service Denmark INVACARE A S Sdr Ringvej 39 DK 2605 Brendby Phone 45 36 90 00 00 Fax 45 36 90 00 0I www invacare dk denmark Dinvacare com Sweden amp Finland INVACARE AB Fagerstagatan 9 Box 66 S 163 91 Sp nga Phone 46 8 761 70 90 Fax 468 761 81 08 www invacare se sweden invacare com Norway amp Iceland INVACARE AS Grensesvingen 9 Postbox 6230 Etterstad N 0603 Oslo Phone 47 22 57 95 00 Fax 47 22 57 95 01 www invacare no norway invacare com Spain INVACARE S A C Areny S N Poligon Industrial de Celra E 17460 Celra Girona Phone 34 972 49 32 00 Fax 34 972 49 32 20 www invacare es contactsp invacare com Switzerland MOBITEC REHAB AG Benkenstrasse 260 CH 4108 Witterswil Phone 41 61 487 70 80 Fax 41 61 487 70 8l switzerland invacare com Invacare EC Hong AIS Ident no 1485245 Version 05 Date 11 2006 CERTIFIED Belgium amp Luxemburg INVACARE N V Autobaan 22 B 8210 Loppem Briigge Phone 32 50 83 10 10 Fax 32 50 83 1011 www invacare be belgiumOinvacare com Netherlands INVACARE B V Celsiusstraat 46 NL 6716 BZ Ede Phone 31 318 695 757 Fax 31 318 695 758 www invacare nl care invacare com Germany AQUATEC GmbH Alemannenstrasse 0 D 88316 Isny Ph
7. o a manipular a elevador de transfer ncia A elevador de transfer ncia foi concebida em conformidade com o Standard Europeu EN 10535 Durante todo o processo de fabrico e produ o a elevador de transfer ncia Invacare Robin foi supervisionada e a sua qualidade controlada sendo o produto final inspeccionado e testado pelo nosso controlo de qualidade As etiquetas e a marca QA s o colocadas na elevador de transfer ncia ap s a aprova o final da elevador de transfer ncia confirmando e garantindo a conformidade com o nosso controlo de qualidade Por Favor leia atentamente este manual de utilizador antes de utilizar a sua elevador de transfer ncia A Invacare EC H ng A S est certificada em conformidade com ISO 9001 e ISO 13485 Table of contents Purpose and application oooooooooooooo ooo 7 As A o eee eeenewee aoe eee 7 L2 Purpose and application sau sio a det aa a a SURE Hoan Ram boon ces paella ads 7 L3 Important Warnings scum uer ace a RUPES REL d RUE ee i ul BHO URS dod Ud 8 LA UNS corra a s ce pla n d a d 100482 iaa ada pata ee ea 9 L5 Unpacking and preparation a as veas 25 hd 9 n8 tc ta aut s ie noel says da 9 6 Installing the charging station ccc ccc ee eee eee 9 L7 Holst system installati n s s ens casio roses m QU Ropa A OR RH a seca as 10 INSPECHON iso ooo aia AAA 5 Il A A Para e Ps In SCR eee ae ee A EA A E MUERE 2 2 Before first time use dora em Prog m padrones Description o
8. strap sensor and adjust if necessary Check the guide cylinder and the end stop Check the straps for wear and damage Check the hooks for damage Check the screws and pins 25 Electrical parts Check the wiring for damage and secure connections Check the micro switches for clamping and their mechanical function Check the hand control for damage and function Make sure that the hand control is securely connected Check the emergency stop lowering 7 4 Troubleshooting Service and maintenance of Robin must only be performed by personnel who have received the necessary instruction and training The hoist is not responding correctly when pressing the hand control buttons and the up down buttons on the hoist are not functioning The hoist is not responding cor rectly when pressing the hand control buttons but the up down buttons on the hoist are functioning The straps will only move downwards and not upwards The straps will only move up wards and not downwards The hoist speed is the same with and without load The lifting straps are twisted and do not straighten out The hoist emits excessive noise when activated The emergency stop is acti vated 2 The battery is discharged 3 The fuse is blown The hand control is not connected correctly 2 The hand control is defect The battery is nearly discharged 2 The load is to high The hand control is defect 2 The loose st
9. 10 years After 10 years use it must be inspected by qualified personnel before further use If the hoist is used in localities with increased humidity a reduction in lifetime must be expected Spare part list for Robin and EC Track can be obtained from Invacare 7 2 Battery To change battery If battery replacement is necessary Robin must be removed from the track system Please see section dismounting Release the upper part of the hoist by removing two screws See picture ak Remove the battery pack inside the hoist by unplugging the wires and replace it with a new one Re attach the upper part of the housing Important Use only Invacare recommended batteries see section Accessories The battery must be located as shown in picture 7 If the battery housing is damaged do not use the battery It is not necessary for an approved service person to carry out the battery change 24 Use of emergency batteries Should the need for immediate use of Robin arise at a time when the hoist has a discharged battery a Invacare emergency battery can be used This battery is connected to the underside of the motor hanging freely during client transportation Use the emergency battery only when absolutely necessary Always recharge this battery after use please see section Charging The emergency battery is an accessory that can be ordered from your Invacare dealer see section Accessories Import
10. 1451913 7035 1451914 7035 1450290 7035 449668 9005 446269 7012 488974 7012 449228 7035 450289 449483 9010 1485 183 9010 1485 183 9006 45 1620 7012 1493121 Article Battery 2 Ah Battery 4 5 Ah Charger kit IP41 for hand control black with 1 8 1 8 m cable bracket and retainers Charger kit IP41 for hand control grey with 1 2 2 m cable bracket and retainers Charger kit IP67 for hand control grey with 0 1 l m cable bracket and retainers Charger kit IP67 for hand control grey with 0 1 2 m cable bracket and retainers Charger kit IP67 for hand control grey with 0 1 3 m cable bracket and retainers Charger kit IP67 for hand control grey with 1 2 1 m cable bracket and retainers Charger kit IP67 for hand control grey with 1 2 2 m cable bracket and retainers Charger kit IP67 for hand control grey with 1 2 3 m cable bracket and retainers Clamp for charger for wall mounting without transformer bracket and retainers Charger for external battery black Distance clamp Flexiscope 4 point spreader bar 450 mm Retainer for hand control strap mounted Gearwheel grease 3 g tube Hoist trolley Inalto Invacare Room to room trolley white EC Track Room to room trolley grey EC Track Extended lifting straps with hooks and emergency lowering strap extra length must be specified when ordering Exercising device NiMH 20 cells of 2 1 Ah 4 2 Transit coupling The room to room coupl
11. Transport The emergency strap must be pulled when the Robin motor is demounted from the tracks for transport or storage otherwise the Robin can be accidentally activated See section 6 2 Storage During transportation the hoist must be placed on a soft surface e g a cloth or foam rubber mat Make sure that Robin remains upright whilst being moved We recommend using the original packaging for transportation under the following conditions e Temperature between 30 and 50 C 4 e Humidity between 10 og 70 RH i A e Pressure between 700 og 1 100 hPa 30 50 C 10 70 700 1 100 hPa 22 122 F 6 Maintenance amp Storage Only Invacare authorised personnel should perform maintenance and service Daily inspection should be carried out by the carer after reading the manual Six monthly inspection according to UK LOLER 1998 regulations should be done also Spare parts list and wiring diagram can be obtained from Invacare or be down loaded from www invacarebeds dk 6 1 Cleaning Cleaning in connection with daily use Lifting slings are to be washed in accordance with manufacturers instructions e Robin and the hand control can be wiped with a moistened cloth Only common cleansing agents must be used never use acids and solvents The strap hooks must be cleaned with water and common cleansers e If disinfection is required dry thoroughly with known brands of liquid detergent 6 2 Storage
12. ant Use only Invacare recommended emergency batteries 7 3 Maintenance When performing annual or regular maintenance all parts designed to carry load must be tested at maximum capacity both hoist and track system All safety features must be checked A function test of the system with 5 x maximum load must also be performed During the service all parts that is exchanged and all work carried out must be documented The worn and defective parts must be replaced with new spare parts from Invacare Inspection of the hoist and track system must be carried out by a qualified Invacare authorised dealer To record the details please use the service schedule on page 25 EC Track system inspection e All bolts fixtures in walls and ceiling must be checked and re tightened if necessary The end stop on the tracks is checked adjusted if necessary and re tightened Systems with track connections should be checked and realigned if the connection has become mis aligned during use Test the trolley and the traverse trolley Check for noise and smooth movement For a traverse system check all functions and connections e Check the friction brake on both the hoist and traverse trolley and adjust accordingly Hoist inspection Mechanical parts Check the suspension pin and the cross axle Check the steel and plastic gear wheels for wear and damage If the gearwheels are dry use the gearwheel grease see accessories Check the loose
13. at the hand control can be readily placed into the charger holder when being charged Therefore place the charger at a maximum distance of 85 cm under the rail in which the hoist is mounted It is important to make sure that there is access to the mains where the charger is placed To mount the charger first insert wall fitting with 2 screws then connect the cable from the charger to the actual holder and press the holder onto the mounted wall support The wall support for the charger must be mounted with three screws under the holder and at a distance that suits the length of the charger cable Connect the charger to the socket outlet and check that it is operational More than one charging unit can be mounted for one hoist as these can work independently Be aware that only an IP67 charger can be mounted in a wetroom See section 8 2 7 Hoist system installation Prior to fitting the hoist ensure that the hoist trolley is mounted Remove the end stop that is attached to the rail track The trolley can then be inserted into the rail It is unimportant which way the trolley is facing The end stop must then be reinstalled See picture When mounting Robin locate the hoist trolley at the 32 mm round recess in the rail See picture Lift the hoist and push the suspension pin through the hoist trolley Turn the hoist 90 degrees to the rail s longitudinal direction and place it as shown below Note Support the ho
14. e g between the back support of the chair and the user The client should not sit on the sling The leg straps are guided forward along the outside of the thigh and in under the thigh between the knee and the hip joint The leg straps are crossed between each other in front of the user All four sling straps are now ready to be mounted into the suspension hooks When the client is lying down he she should be log rolled onto their side Position the sling in such a way that the upper edge is in line with the crown of the head The user is then repositioned onto his her back and log rolled in the opposite direction The sling is then rolled to be flat under the user when he she is rolled onto his her back The leg straps are then guided in under the thigh bone and crossed in between each other All four six sling straps are now ready to be attached If there is doubt as to the use of the sling please contact Invacare 3 Important warnings Read the entire manual before using Robin Robin s max load of 200 kg must not be exceeded If accessories are rated with a lower load than 200 kg this determines Robin s maximum load Robin must only be used to move a patient Robin must not be used where there is a risk of contact with water If the Robin is damaged it must be taken out of use Call your local Invacare dealer or Invacare s service department e The cord for emergency stop emergency lowering is to be adjusted so it is
15. e personnes Invacare Robin de Invacare EC Hang A S Votre nouveau l ve personnes est marqu CE conform ment la directive 93 42 EEC concernant les dispositifs m dicaux Invacare Robin a t d velopp et construit en consid rant syst matiquement les besoins de l utilisateur et des tierces personnes lors de la manipulation du l ve personnes ou de son utilisation Invacare Robin a t d velopp conform ment au Standard Europ en NF EN 10535 et NF EN 60601 2 38 Invacare Robin a t supervis et contr l tout au long du process de fabrication et le l ve personnes achev a t inspect par le contr le des produits finis La plaque d identification et la marque QA sont plac es sur le l ve personnes attestant que le contr le des produits finis a approuv le l ve personnes Le l ve personnes r pond aux exigences de l analyse de risques de la norme NF EN 14971 Nous vous remercions de lire le Manuel de l Utilisateur dans son int gralit avant d utiliser le l ve personnes Invacare EC Hang A S est certifi e ISO 9001 et ISO 13485 PT DECLARA O DE QUALIDADE Parab ns pela sua nova elevador de transfer ncia Invacare Robin da Invacare EC H ng A S A elevador de transfer ncia tem a marca CE em conformidade com a directiva 93 42 EEC referente a aparelhos m dicos A elevador de transfer ncia foi concebida e desenhada tendo em considera o o seu utilizador e o seu s assistente s que o ajudar
16. ed dealer When the Robin ceiling hoist is used in an institution or in a nursing home it should always be operated by specially trained staff and used in recommended track systems The track system must be installed by Invacare personnel or an authorised dealer Seated to seated transfer During a seated transfer e g from a wheel chair the Robin should be positioned close to the person to be lifted The suspension hooks should ideally be positioned level with the chest and ideally no further than over the middle of the thigh Place the suspension hooks parallel with the user s shoulders See picture The sling may now be attached to the suspension hooks For placement of the sling see section Placement of the sling Lying to lying transfer Position the suspension hooks above the person to be lifted aligned to the users shoulders see picture If possible raise the back portion of the bed so that the user may be lifted in a seated position The sling may now be attached to the suspension hooks For placement of the sling see section Placement of the sling Placement of sling The sling straps are to be hooked in pairs one from the back and one from the leg on their own suspension hook Attachment of the sling is described in the respective user manual the text and picture below is only a principle explanation With the person to be lifted in sitting position the sling is placed behind the user s back
17. eries Local and national regulations for environmental recycling must be followed Batteries must always be delivered to an approved collection place Disposal must always follow the relevant local laws and regulations for waste and scrap 29 10 Service schedule Service and maintenance of the hoist must be carried out only by trained experienced personnel Personnel hoist serial number Inspection point pate p d T Inspection of the track system All bolts fixtures to wall and ceiling must be checked and re tightened if necessary End stops on the tracks must be checked moved if necessary and re tightened Systems with track connections should be checked and re aligned if the connection has become mis aligned during use Check trolley and traverse trolley pp Check trolley wheels for smooth movement and abnormal noise Check friction break adjustment on trolleys Adjust if necessary Inspection of hoist Mechanical parts Check steel and plastic gear wheels for wear and damage BEEN O O ee ee If gear wheels are dry apply gearwheel grease see accessories Check loose strap sensor and adjust if necessary So ST T Check guide cylinder and end stops Check straps for wear and damage Check the lifting hooks screws and pins for wear and damage EN O O eee ee Check the wiring for damage and correct connections Check micro switches for clamping and mechanical function
18. f functionS oooooooooooooo o oooooo Il 3 1 Description of the hoist s main parts eee eee 9 2 ODEON usas vb ERE daa tato pea UNE PME ATE va 12 al a 1 soeur UPN O EN 13 O O 3 3 5 Charging an emergency battery oooooooooooooorrorrrrmooooooo o 4 3 5 Battery MaltananCO ooo wea es eder con B SR ER a r ai iai 8 QUEM AP eee en a ae 4 AECESSOFIES 6 4 orrrrrrrrr rre recorra 15 dl VACGCOSSOFPIGS xcu ARENA ETE RERUM LR d eK edt Ka ERR ION Eu ease ad 5 42 Transit COUDIING aic condos FORD UHR RR UIS GU DS V ERE NEUSS EUR Duk riam AR l6 E E DE oct ma a ia d a a ct 7 aaa iv JR oe ee tase eee ae ta 1 eee nee ae 17 43 1 EC Gantry Traverse circus dua amo Ja nar EO doen tana odias 18 44 FEOXSCOPS baba cone RP CER au a RE GNIS RE GP se d 19 4 5 Mounting of 4 Point spreader bar o oo ooooocccocococococoncnooooooooooo 20 4 6 Track switch Manuale osease aude e palets ia a 21 4 7 Room to TOOITEPASIB S s ose D O 22 Dismounting amp transport 23 p DINOU 304604840006 ondaa RIPE eae Res d ARS ud pe Er mM E d 23 5 2 WranspOHtoibens vns xr au Ede E BONA EINE RUIN RE PENA UR ER UE c va 23 Maintenance amp Storage 23 ANS ereenn ere TETERE nalta EEE ETE M i d pa Ii tal 23 OR erei e sos rara a IAR iso iu d lt a A 8 me eters a e baia da 23 6 3 Maintenance performed by owner llle 23 Service amp lifetime
19. haf van uw nieuwe plafondlift Robin van Invacare EC Hong A S Invacare Robin is CE gecertificeerd en goedgekeurd conform richtlijn 93 42 EEC betreffende medische hulpmiddelen Invacare Robin is ontwikkeld en geconstrueerd met inachtneming van de behoeften van de gebruiker en verzorgers Invacare Robin is ontwikkeld in overeenstemming met de Europese Standaard EN 10535 Gedurende het gehele productieproces is het Robin bed gecontroleerd op kwaliteitsaspecten en het complete plafondlift is na productie zorgvuldig gecontroleerd Het productlabel en de QA markering zijn op het plafondlift bevestigd om aan te tonen dat de plafondlift zijn gecontroleerd en goed zijn bevonden door de afdeling productcontrole Wij verzoeken u vriendelijk de gehele gebruikershandleiding te lezen voordat u het plafondlift in gebruik neemt Invacare EC Hang A S is ISO 9001 en ISO 13485 gecertificeerd IT DICHIARAZIONE DI QUALIT Complimenti per aver scelto il sollevatore da soffito Invacare Robin prodotto da Invacare EC Heng A S Il vostro nuovo il sollevatore da soffito marcato CE ai sensi della Direttiva 93 42 EEC relativa ai dispositivi medici Il il sollevatore da soffito stato progettato e costruito con un occhio di riguardo per gli utilizzatori e per i loro assistenti Invacare Robin stato realizzato nel rispetto della Normativa Europea EN 10535 Il sollevatore da soffito stato oggetto di accurate verifiche qualitative duran
20. ing can be used in the rail system where there is a requirement to transfer a patient between two rooms The room to room coupling can be used when there is traverse system in both rooms or travers system in one of the rooms and mono rail in the other room A To transfer a patient between rooms place the hoist with load right under the mono system See drawing A point Then move the Robin and tracking so that the two sections of track line up with each other See drawing A point 2 B Press the button on the wall mounted control box See drawing b point 3 When the tracking is locked in place the green light illuminates and the transfer can be carried out See drawing B point 4 amp 5 C When the Robin is safely located on the new section of tracking the button on the control box can then be pressed again to unlock the two sections of tracking See drawing C point 6 amp 7 D The green light will then go out to indicate that the two sections of tracking can be safely moved away from each other See drawing D point 8 amp 9 It is esssential that during the transfer process you locate the Robin Mover as indicated in the above diagrams this will ensure the safe coupling of the tracking sections If in doubt or you experience difficulty in coupling the tracking contact your Invacare dealer 4 3 EC Gantry The EC Gantry is used where there is a req
21. ist if a client unintentionally traps his her hand in the lifting strap during a lift The hoist will stop immediately when the hand makes contact with the strap inlet If Robin is loaded with a weight of more than 200 kg the hoist will automatically turn off to safeguard against overloading Electromagnetic interference between the hoist and other electrical products can occur To reduce or eliminate such electromagnetic interference increase the distance between the hoist and the products or switch off the products 3 4 Charging A sound indicator and the flashing indicator light signals when the hoist needs to be charged The hoist must be moved along the rail system and parked nearby the wall mounted charger Attach the hand control to the charger unit LED on the charger indicates that charging is taking place We recommend parking the hoist in the charging position when not in use LED indication Function duration Initializing and analysis of battery 2 14 seconds P E ETT Alternating red and green Fault condition battery defect Mg There will still be sufficient power to lower the user from the time when the hoist indicates that charging is needed If the battery should become totally discharged while a transfer is in progress an external battery may be tempo rarily connected to the hoist See the section Battery NB It is recommended to interrupt the charging and pull the emergency stop when the lifter has no
22. ist while turning See picture If Robin is correctly mounted into the trolley it is now possible to pull the trolley back and forth along the rail If there is excessive resistance or if the trolley unintentionally rolls by itself due to imbalance in the rail suspensions adjust the friction brake using a 4 mm Allen key See picture When the system is installed the hand control must be connected and the cord for the emergency stop lowering must be adjusted so it is within the user s reach The system must be inspected before use see section Before first time use Robin is now ready to be used in the EC Track system When using Robin in other rail systems an alternative trolley must be used Contact Invacare for information regarding approved systems 2 Inspection 2 Approvals The Robin ceiling hoist has been tested and approved in accordance with Lift standard EN ISO 10535 and is TUV approved The hoist is C marked in accordance with the medical directive and standard EN ISO 10535 2 PRODUCT SERVICE Production monitored Safety tested 2 2 Before first time use Before first use all features of the hoist system must be inspected by a authorised Invacare installer The hoist is not intended to be used together with MEDICAL ELECTRICAL EQUIPMENT 3 Description of functions 3 1 Description of the hoist s main parts Control button UP Control button DOWN Connection for hand control
23. n the charger for long periods of time In this situation there will always be capacity enough for few lifts but we recommend to exercise the battery as soon as possible afterwards Exercise of the battery can be done in two different ways either by charging and deplete the Robin motor completely several times or by placing the battery in an exercising device See section 4 Accessories Exercise by charging and decharging the Robin motor is done by charging the motor until the light indicator is green The motor is then removed from the charger and the straps with load are lowered and raised for one minute and then 10 minutes break continue this procedure until the battery is completely decharged continue even when the sound signal for low power bleeps Charge the battery Motor and lower and raise the straps until the battery is decharged again Repeat this procedure 2 3 times The battery can alternatively be exercised in an exercising device which is available as an accessory for the Robin hoist The battery is removed from the Robin motor and placed in the exercising device see instructions enclosed with the device The exercise method in which charging and deplete the battery several times is carried out is very time consumning we therefore recommend that you use the exercising device 4 Accessories 4 Accessories Order no 1444013 1444014 1446317 1492102 7035 1451909 7035 1451910 7035 145191 1 7035 1451912 7035
24. nto the Gantry s legs There is a risk of tipping if the patient is very unsettled or suffers from spasm in the sling Never leave a patient in the sling unattended 4 4 Flexiscope Scope Flexiscope is used with the Invacare Robin ceiling hoist in connection with the transfer or moving of disabled patients who require extended distance between the slings shoulder straps Max load 200 kg Installation Installation of Flexiscope on the lifting straps is carried out according to the illustrations Adjustment Alignment of the width is made by pulling the button A while moving the strap bar B to the desired position Note Ensure that the bar is correctly engaged Maintenance and cleaning Cleaning in connection with daily use e All painted surfaces can be whiped off with a damp cloth Only household detergents are allowed Never use acids alkalines or solvents such as acetone or cellulose thinner Desinfection of Flexiscope it must be whiped over with officially approved detergents only e The black cover is removed from Flexiscope and can be mashine washed at 70 C do not tumbledry bleach or dry clean 4 5 Mounting of 4 Point spreader bar e Lower the Robin lifting straps down to a suitable height and mount the spreader bar shown on the illustration below e Use only the spreader bars produced for Robin e Ensure that the spreader bar suits the client and the type of lift required Ensure the sp
25. one 49 75 62 700 0 Fax 49 75 62 700 66 www aquatec de info aquatec de Portugal INVACARE Lda Rua Senhora de Campanha 105 P 4369 001 Porto Phone 351 225 1059 46 47 Fax 351 225 1057 39 www invacare pt portugal invacare com Australia INVACARE Australia Pty Ltd Lenton Place North Rocks NSW 215 Phone 61 2 8839 5333 Fax 61 2 8839 5353 www invacare com au sales invacare com au QUALITY SYSTEM DS EN ISO 9001 DS EN ISO 13485 France INVACARE Poirier S A S Route de St Roch F 37230 Fondettes Phone 33 2 47 62 64 66 Fax 33 2 47 42 12 24 www invacare fr contactfr invacare com Italy INVACARE MECC SAN S R L Via dei Pini 62 I 36016 Thiene VI Phone 39 0445 38 00 59 Fax 39 0445 38 00 34 www invacare it italia invacare com United Kingdom amp Ireland INVACARE LTD South Road Bridgend Industrial Estate UK Bridgend CF31 3PY Phone 44 656 664 321 Fax 44 656 667 532 www invacare co uk uk invacare com New Zealand INVACARE NZ 4 Westfield Place Mt Wellington Auckland Phone 64 9 917 3939 Fax 649917 3957 www invacare co nz sales invacare co nz Austria MOBITEC MOBILITATSHILFEN GmbH Herzog Odilostrasse 101 A 5310 Mondsee Phone 43 6232 5535 0 Fax 43 6232 5535 4 www mobitec austria com austria invacare com Manufacturer INVACARE EC Hong A S Ostergade 3 DK 4270 Hong www invacarebeds dl
26. rap function is activated The lifting hooks do not turn freely enough 2 The straps are frayed Possible cause Action Depress the emergency stop button 2 Put the hoist on charge or use the emergency battery 3 Replace the fuse Secure the plug 2 Replace the hand control Put the hoist on charge or use the emergency battery 2 Reduce the load the hoist is equipped with a over current safety system Check the hand control it s connection and the re entering endstop Replace the hand control 2 Check the loose strap switch The non load quick movement Check the quick movement function is activated permanently switch Clean or replace the hooks 2 Replace the straps Defect bearings gearwheels or Replace the hoist motor If the above mentioned does not solve the problem please contact Invacare Service Department 26 8 Technical specifications Number of lifts per charge Lifting velocity at 200 kg load Max lifting interval Height from celling to sling hook Total weight without sling Electrical connection of charger 230V AC 50Hz Voltage current between charger hoist 24V DC 900mA 50mA Batteri 20 pcs 1 2V 2 0 Ah AA ULL 20 pcs 1 2V 4 5 Ah 8 1 Symbols Warning SWL Safe Working Load Max load patient sling other accessories Class Il equipment Type B equipment patient not separated from ground CE marking
27. reader bar is correctly mounted before use 20 4 6 Track switch manual The track switch is used in track systems where a change in direction is required during movement of the patient The track switch is operated by pulling the cords on either side this change in direction must be carried out before the client is guided into the drive switch area The direction is changed and the hoist will take the direction to the side where the cord is pulled The track switch is mechanically secured against derailing 21 4 7 Room to room transfer The two hoists are moved as close to the doorway as possible The sling is attached to hoist A The lifting straps on hoist are lowered as far as possible with concideration to the patient s comfort 2 The two lifting straps on hoist B are lowered as much as necessary to attach them to the sling Note Ensure that the lifting strap hooks are installed correctly 3 The lifting straps of hoist B are raised while the straps on hoist A are lowered Continue until the patient is completely suspended by hoist B 4 The lifting straps on hoist A is now uncoupled from the sling and rewound Note Beware of dangeling hooks or hand control 5 The lifting straps on B are rewound to the desired height The room to room transfer is now carried out 22 5 Dismounting amp transport 5 1 Dismounting When dismounting Robin please see section Installation of hoist system 5 2
28. t been used for more than 4 6 weeks Note It is not possible to use the hoist whilst charging the battery If the sound indicator of the Robin beeps and the blue function lights flash after Robin that has been fully charged and has been in use for only a short period of time the battery may be ready to be replaced by a new one See section 7 2 Battery Another possible option could be that the battery needs to be excercised See section 3 6 Battery maintanance 3 5 Charging an emergency battery The emergency battery package is charged by placing the plug in the charger socket A special adapter is necessary The LED light turns green to indicate the unit is fully charged appox charging time 2 hours 3 6 Battery Maintanance If the sound indicator of the Robin bleeps and the blue function lights flash are flashing after Robin that has been fully charged and has been in use for only a short period of time the battery might need to be exercised To enable the battery to be charged fully it is neccessary to exercise the battery from time to time This will be dependant on how often the Robin is used Following a long period of storage the battery should be exercised It is only possible to exercise the battery even if the emergency strap has been pulled down See section 5 2 Transport It is suggested that the battery is exercised in situations where a Robin is used infrequently and or where the hand control is placed i
29. tagen til de sikkerhedsmeessige krav i den Europ iske Standard EN 10535 Hver personlofter har gennem hele produktionsforlobet v ret overv get og kontrolleret og den f rdige personlofter er blevet inspiceret af vores feerdigvarekontrol Typeskilt og QA maerke p s ttes personlofteren som dokumentation for at feerdigvare kontrollen har godkendt personlefter For ibrugtagning af Deres personlofter skal De genneml se brugermanualen grundigt Invacare EC Hang A S er certificeret i henhold til ISO 9001 og ISO 13485 DE KONFORMITATSERKLARUNG Herzlichen Gl ckwunsch zu Ihrem neuen Deckenlifter Invacare Robin von Invacare EC Hong A S Ihr neuer Deckenlifter ist gemaB der Richtlinie 93 42 EWG f r Medizinprodukte CE gekennzeichnet Der Invacare Robin wurde unter Ber cksichtigung der Bed rfnisse von Benutzer und Pflegepersonal entwickelt und in bereinstimmung mit der Europ ischen Norm EN 10535 konzipiert und hergestellt W hrend des gesamten Herstellungsprozesses unterliegt der Invacare Robin einer st ndigen Qualit tskontrolle und wird im Anschluss nochmals durch unsere Endkontrolle gepr ft Das Typenschild und QA Kennzeichen sind am Deckenlifter angebracht um die Abnahme durch unsere Qualit tskontrolle zu best tigen Bitte lesen die gesamte Bedienungsanleitung bevor Sie den Deckenlifter in Gebrauch nehmen Invacare EC Heng A S ist zertifiziert nach ISO 9001 und ISO 13485 NL KWALITEITSGARANTIE Gefeliciteerd met de aansc
30. te l intero processo produttivo una volta completato stato controllato dal nostro servizio prodotti finiti Un apposita targhetta e la marcatura QA sono state apposte sul il sollevatore da soffito a conferma dell avvenuta verifica e accettazione del prodotto da parte del servizio qualit Prima di utilizzare il il sollevatore da soffito vi invitiamo a leggere integralmente il manuale d uso Invacare EC Hang A S un azienda certificata ai sensi della Normativa ISO 9001 e ISO 13485 ES DECLARACI N DE CALIDAD Enhorabuena por su nueva elevador de techo Invacare Robin de Invacare EC Hang A S Su nueva elevador de techo cuenta con el marcaje CE de acuerdo a la directiva 93 42 EOF que hace referencia a los aparatos m dicos Invacare Robin ha sido dise ada y fabricada teniendo en cuenta a los usuarios y las personas que los asisten La elevador de techo Invacare Robin ha sido dise ada de acuerdo a la normativa Europea EN 10535 El proceso de producci n del modelo Invacare Robin ha sido supervisado en su totalidad y su calidad inspeccionada por nuestro control de producto acabado La elevador de techo cuenta con una placa y marca CE que confirma que la misma ha sido inspeccionada por el control de producto acabado Por favor lea el manual antes de utilizar la elevador de techo Invacare EC Hong A S es una empresa certificada ISO 9001 e ISO 13485 FR D CLARATION DE QUALIT F licitations Vous avez choisi votre nouveau l v
31. uirement for a free standing rail system Height range for EC Gantry without wheels 216 25 cm Height range for EC Gantry with wheels 195 230 cm The EC Gantry is available with or without wheels To increase the height of the EC Gantry pull the leg section upward To decrease the height of the EC Gantry pull the handle as indicated above adjust the EC Gantry to the desired height and then release the handle to allow the leg section to lock back into place Wih regards to the safety of the patient it is recommended that the EC Gantry is not moved with a patient hanging in the sling It is important that the EC Gantry is placed on a level surface with regards to the risk of tipping Please observe that there is a risk of the patient swinging into the EC Gantry s legs There is a risk of carer stumbling over foot of the EC Gantry system There is a risk of tipping if the patient is very unsettled or suffers from spasm in the sling Never leave a patient in the sling unattended 4 3 1 EC Gantry Traverse The EC Gantry Traverse is used where there is a requirement for a free room covering standing rail system Height range for EC Gantry Traverse 218 253 cm i A D a 9 Y Pa It is important that the EC Gantry Traverse is placed on a level surface with regards to the risk of tipping Please observe that there is a risk of the patient swinging i
32. uring a more comfortable lifting and lowering movement of the user Transport running in the rail system The empty hoist can be moved along the rail system by pulling the two lifting straps The hand control must not be used to pull the hoist along During a transfer the carer should gently push or pull the client sitting in the sling 3 3 Safety guidelines Emergency stop If the hoist straps moves unintentionally upwards or downwards pull the emergency stop chord When the emergency stop is activated the hoist will not operate If the emergency stop button is pushed up the hoist will be ready for use again Emergency lowering The emergency lowering feature can be used in order to lower a client to the transfer surface if the hoist has become inoperable Emergency lowering is operated by continuously pulling the cord When the emergency lowering function is activated all end stops and security functions are deactivated It is thereby possible to wind up the lifting straps back up when activating the emergency lowering for prolonged periods Strap securing pinch protection If the lifting straps are guided incorrectly in and out of the hoist i e if the straps has become twisted the hoist will automatically turn off Note When attaching the sling to the hooks and the straps are twisted the straps will rotate and stretch out thus ensuring trouble free operation The pinch protection feature automatically turns off the ho
33. within the user s range Risks when using the hoist Risk of entrapment between hook and hook housing Risk of entrapment between hooks and sling when lifting Risk of injury to client and carer caused by dangling hooks or hand control 1 4 Sling s Use only C marked sling s with a rated load equal to or lower than that of the Robin s max load The sling must be suitable for 2 or 4 point spreader bars please look at Invacare s brochure concerning slings i e with sewn lifting loops that can be mounted onto a 2 or 4 point spreader bars 5 Unpacking and preparation Perform a visual inspection of Robin If the packaging is damaged upon arrival Robin parts must be thoroughly examined for visible damage or defects If there is any suspicion of damage Robin must not be used before qualified service personnel or service technicians have approved the hoist It is to be expected that the hoist s battery is discharged on account of self discharge The hoist must therefore be charged for up to 2 hours before first time usage refer to section Charging The following is to be included in the package Robin 2 Handcontrol 3 User manual The charging unit must be ordered separately part no 1446317 6 Installing the charging station The charging unit should be attached to the wall or the most practical place within reach of a socket outlet to park the hoist when not in use It is important to make sure th