         Contents
1.         a        Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 8    www ntn snr com       8  OPERATING INSTRUCTIONS    8 1 BEFORE PUTTING INTO OPERATION   Note that the unit should not be dismantled by the user if a fault is found    e Use gloves when handling lubricants and ensure you have checked the lubricant safety data sheet   e Do not use lubricants that are incompatible with NBR  Buna  seals    e Ensure that you have complied with all health and safety requirements before putting the pump into service   e Maintain proper hygiene standards  Never ignore any potential danger to heath    e Ensure all tubing and fittings are designed to handle the maximum system pressure    e Check integrity in the pump  Ensure no damage    e Check and fill the reservoir  If the reservoir is below the MIN level  follow procedure 8 3 to refill    e Verify the pump is at the correct operating temperature and tubing is free of air bubbles    e Check the unit is properly wired     8 2 OPERATION   e Check and set the operating mode and parameter if using the automatic versions   e Press the remote start button on your machine if using a manual version    e Check that the pump is running    e Check lubricant is being delivered to the greasing points as necessary     8 3 REFILLING THE RESERVOIR   The refilling of the tank is carried out through the dedicated filling ports with adequate filtration to ensure clean 
2.    74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 2    www ntn snr com       The diagram on the left shows a typical schematic of a simple centralized  lubrication system    The main components are           Electric Pump with Reservoir  eg  MULTIPULSE AC Pump     B     Primary lubrication line for distributing grease    C     Distributor elements that meters grease into a number of points    D     Secondary tubing that delivers grease to the lube point                                            The pump feeds a distributor element that shares and doses the ratio of grease or oil between the several points   The MULTIPULSE AC Pumps have been designed to provide the pumping solution for such systems used in industrial  or mobile applications for greases up to NLGI 2 consistency and oils with minimum viscosity of 46 cSt     3 2 MULTIPULSE AC ELECTRIC GREASE PUMP FOR FIXED APPLICATIONS   MULTI   PULSE AC is an electric piston pump with the pumping element operated from a camshaft connected to a reducing  gearbox  It can be fitting with up to 3 pumping elements  1 as standard  which are available with or without an integrated  pre set bypass  pressure safety valve   The MULTI PULSE AC also has a modular build reservoir supplied in 5 liter  capacity  Additionally a minimum level sensing device is fitted as standard at the base of the unit    MULTPPULSE AC is available as both with an integrated automatic control board that controls and monitors the pu
3.    MULTIPULSE AC  Lubrication pump for fixed  Industrial applications    User operation and Maintenance  manual  Warranty    Manual drawn up in accordance with EC Directive 2006 42    CE    Pour obtenir ce manuel d utilisation en fran  ais  veuillez consulter notre site Internet    www ntn snr com   Um unsere deutsche Gebrauchsanweisung zu erhalten  besuchen Sie uns auf unserer  Homepage  www ntn snr com   Para conseguir este libro de instrucciones en espa  ol  consultar nuestro sitio Internet    www ntn snr com   Per ricevere questa guida utente in italiano  si prega di visitare il nostro sito Web   www ntn snr com       Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1    www ntn snr com       1  TABLE OF CONTENTS    1 Table of contents 10 Maintenance procedure  2 Introduction   11 Disposal   3 General description   12 Spare Parts   4 Product identification   13 Dimensions   5  Technical characteristics 13 Handling and transportation    6 Pump components   14 Operating hazards  7 Unpacking and installing   15 Precautions   8 Operating instructions E 16 Warranty   9  Troubleshooting   17 Declaration of conformity       2  INTRODUCTION    This user and maintenance manual refers to the MULTI PULSE AC lubrication system    This manual should be conserved in such a way that it remains undamaged over time and is readily available to personnel  needing to consult it    The manufacturer reserves the 
4.   standby  cycle  it will make the pump starts a lubrication cycle and then return to normal  automatic operation  The RESET of the pump is allowed when the button is pressed for 6 seconds     8 4 1 OPERATING MODE     The MULTPPULSE Manual version does not have any adjustable feature as there is no local controller  You should  arrange to control the pump ON OFF with a host system that activates the pump as required and monitors the lubrication  system  including checking level switch and cycle switch when installed     Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 0    www ntn snr com       8 4 2 OPERATION MODE     AUTOMATIC VERSION MODE CYCLE      ALARM  Pump stand by Pump working Cycle sensor  TIMEOUT     Exemple 1  Timer based pause and lubrication cycle  1 sec    99 min      P Hou 2 1  P Cou   0  C Min 2 1  C Cou   0    X    0 min   99 hours Only low level       Exemple 2  Timer based pause   Lubrication cycle with monitoring of cycle sensor     A  P Hou 2 1  P Cou   0  C Min 2 1 C Cou 2 1    J Omin  99 hours       Exemple 3  Pause cycle determined by external impulse   Lubrication cycle monitors cycle sensor      P Hou   0  P Cou 2 1  C Min 2 1  C Cou 2 1    i TELEF    0     60 000 cycles    Exemple 4  Pause determined by either time or extend impulse      P Hou 2 1  P Cou 2 1  C Min 2 1 C Cou 2 1 PTOA OFF   Whichever first       ee 0     60 000 cycles    _              oa    Exemple 
5.  all necessary safety precautions    e Contact with lubricant during maintenance or filling of the reservoir   1 As per previous point  correct precautions must  be taken to protect from contact with lubricant    eMoving Parts and crush danger   All moving parts are enclosed within the pump unit  Do not open the pump unit   Appropriate danger labels are located on the pump    eElectric shock   All electrical connections must be carried out by a qualified electrician who hasstudied the connection  to remove electrical danger    e Abnormal operation posture   The pump should be installed in a suitable position with ample clearance as indicated in  this manual to avoid abnormal posture for the operator    e Unsuitable Lubricant    Lubricant characterstics are indicated on the pump and in this user manual  In any case contact  a NTN SNR Support engineer                 Lubricants with abrasive additives  Lubricants with silicone based additives    Petrol     solvents     inflammable liquids  Corrosive products  Water  Food substances    17  WARRANTY    All products manufactured and marketed by NTN SNR Roulements are warranted to be free of defects in material or  workmanship for a period of at least 12 months from date of delivery   Extended warranty coverage applies if complete system installation by NTN SNR Roulements  12 Months        If a fault occurs  notify NTN SNR giving      a complete description of the alleged malfunction    the part number s      date of delivery     d
6. 2 test grease used during  the assembly of the pump     The following table shows the comparison between NLGI  National Lubricating Grease Institute  classification and ASTM   American Society for Testing and Materials  for greases and cSt  Centi stokes  e SUS  Saybolt Universale  for oil                     SUS  213 3  323  462 6    si  ICC   eme     o f ww  DRE    310   340 150 694 2  265   295 220 1018  For further technical information and on safety  320  1480  information consult the lubricant MSDS Safety data  sheet or equivalent document supplied by the  lubricant manufactuer  3239  1000 4628        Siege social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 8    www ntn snr com       16  PRECAUTIONS    The verification of conformity with the essential safety requirements and regulations of the Machine Directive is effected  by means of the compilation of a check list which has been pre prepared and is contained in the technical file    The lists which are utilised are of three types    e list of dangers  appendix A  EN 1050     e application of essential safety requirements  Machine Dir    att  1  part 1     eelectrical safety requirements  EN 60204      The following is a list of dangers which have not been fully eliminated but which are considered   acceptable    e During installation there may be low pressure oil coming from the pump  Always use appropriate protective clothing   gloves and take
7. 5  Pause determined by extend impulse  pause time generates  alarm if impulses not received     P Hou 2 1  P Cou 2 1  C Min 2 1  C Cou 2 1  PTOA ON   ba _  F 1 min   99 hours  PEN ES DT LE    Pause time  overun       1     60 000 cycles    I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  I  oll  I  I  I  I  I  I  I  I  I       Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 1    www ntn snr com       8 4 3 OPERATION MODE     AUTOMATIC VERSION MODE PULSE    Pump stand by Pump working EOL    e Pause and lubrication cycle determined by external impulse   P Cou 2 0  C Cou 2 1   e During lubrication  cycle sensor monitored to confirm  correct lubrication  C Min 2 1  Suspend Mode  e C Min determines how many min  seconds to allow for the cycle pi  sensor   e Lubrication cycle is suspended if external impulse not detected  within user preset time  S Min 2 1     i  S Min      0   60 000 cycles 1     60 000 cycles E g e     i dl    _Y TULA  _ JUUU OS pg Biji    Dydi sensor       8 4 4 OPERATION MODE     AUTOMATIC VERSION MODE OFF  Pump operates when external signal is given  No monitoring     NOTE   When power is removed from the Bravo  the electronic control will save the cycle  condition in memory  When power is reapplied the controller will resume the logic from  exactly the same point  unl
8. DS    WARNING  It is necessary to carefully read the instructions and the risks involved in the use  of lubrication machines  The operator must know the machine functioning through the User  and Maintenance Manual     Electric currents   No intervention must be attempted on the equipment without first having disconnected the electrical power supply and  ensuring that it cannot be reconnected during the intervention    All installed equipment  electrical  electronic  tank and base structure  must be connected to the ground line utilizing the  terminals fitted to each component     Flammability  The oil employed in the lubrication circuit is not normally flammable  It is nonetheless indispensable to take every  precaution against the oil coming into contact with very hot parts or open flames     Pressure  Prior to any intervention on the equipment ensure that pressure is released from all branches of the lubrication circuit   Failure to do this could result in oil being discharged under pressure where connections or components are disassembled    Noise  The MULTIPULSE AC lubrication panel does not emit excessive noise  remaining below 70dB A    WARNING  before carrying out the replacement of the mini pumps  empty the tank of lubricant     15 1 LUBRICANTS    NOTE  The pump has been designed to operate with max NLGI 2 grease or min 46cst Oil   oil version   Always use lubricants compatible with NBR  Buna  rubber seals    Any residual lubricant found on new units is residual NLGI 
9. E Ico ery Check valves and system schematic  Lubricant does not reach   connected or sized    lubrication points on each      pump cycle or irregularly Incorrect Pause Cycle Settings Ensure that the system designs and settings allow for at  least a full cycle for all distributor valves in the system  Reservoir is empty Refilll  and verify any low level alarms    Disconnect the primary tubing from the pump and  operate a lubrication cycle    Check that clean  air free grease is coming from  the pump and then reconnect the tubing     No lubricant from pump Incompatible lubricant  Some lubricants are not suitable for automatic pumping  systems  Replace the grease     Dismantle the pumping element and check  Blocked pumping element ae    for contamination  Clean and reinstall or repalce   Worn pumping element Replace pumping element    eck power and voltage   The display is not lit Incorrect power voltage Ensure proper power supply to pump          Power missing Power missing           Air bubble in grease         The pump starts the  lubrication cycle but    Allow the pump to cool  Retry the lubrication cycle   If the problem persists It will be necessary to replace    Defective or blocked Pump    then immediately stops moror the pump motor assembly     Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 5    www ntn snr com       NTN  ENR    Alarm codes    Low lubricant level in Refill with clean l
10. TING  MODE       Display total days in working state  Display total minutes in working state  O    res  Display total days in pause state  Display total minutes in pause state  Release  Display total days in alarm state  Display total minutes in alarm state    Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 3    www ntn snr com       8 5 PROGRAMMING THE ELECTRICAL CONTROLLER    OPERATING PARAMATERS    DISPLAY DESCRIPTION MODE DEFAULT       RANGE NOTES    Cyclo 100     O min      oe 99 min    PAUSE TIMER  SET Hours and Minutes 10 min Both    O sec      PULSE 99 min    TIMER to suspend the cycle 0 sec    CYCLE  PULSE    PAUSE COUNTER     number of divider switch cycles to wait in pause 1 cycle    60000 Complet cycle    CYCLE TIMER    if timed cycle it indicates the duration    if cycle with control impulses  indicates the waited  maximum time of the single impulse before alarm     CYCLE  PULSE    99 min    1 sec    CYCLE COUNTER  number of divider switch  cycles per lubrication cycle  input used    e Sensor Cycle if Cycle Mode   e Sensor Pause if Pulse Mode    CYCLE    PULSE nee    60000 Complet cycle    3   D  O o on O o o  MBE   l l    PRELUBE  Start     controller in Lubrication mode CYCLE OFF  when powered on  PULSE OFF  Motor DUTY  100    allows reduction in pump output by adjusting 100    motor speed       9999    Number of cycles given from the manual input CYCLE   it allows eventual fil
11. ansformer    Maximum Output load capability  Short circuit  amp  Overload protection 7 5A typical 10A max   Operating temperature  20  C to  80  C    Storage temperature  30  C to  90  C          e Overload protection on motor and lamp  e Integrated Motor protection    FANS prolecien e Spike voltage protection    e Inverted Polarity protection    Memory for parameter storage EEPROM    Memory Life Unlimited  no battery requirement   Minimum Level    AUTOMATIC version OJA   230V  Max load  MANUAL version 0254   120V       NOTE Pump output has been determined at the following conditions  NLGI 2 Grease Standard  environmental conditions  Temperature 20  C   68  F  Pressure 1 ATM   Back pressure 50 bar   735 psi      WARNING  Do not operate the unit outside the specified voltage ranges     Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 4    www ntn snr com       Stirrer device  with wiper  Modular Reservoir    Connection point for  Pumping element 3    Pumping Element 1 Refilling point    grease nipple    i   Connector plate       Return port 1 8 BSP    multi     l                 _         Control panel   mr   automatic version     i A      N   a a  2  dl     g      Connection point for  Pumping element 2    6 1 ELECTRONIC CONTROL BOARD   In the automatic version  pump and cycle control is managed by the onboard controller  Three operating modes are   possible    1  CYCLE  Lube and pause cycles ar
12. ate of installation     operating conditions of subject product s     We will subsequently review this information and supply you with either servicing data or shipping instruction and returned  materials authorization  RMA  which will have instructions on how to prepare the product for return     NTN   SNR Roulements reserves to right to charge an administration fee if the product s  returned are found to be not defective   This limited warranty does not cover any products  damages or injuries resulting from misuse  neglect  normal expected  wear  chemically caused corrosion  improper installation or operation contrary to factory recommendation  Nor does it  cover equipment that has been modified  tampered with or altered without authorization    Consumables and perishable products are excluded from this or any other warranty    No other extended liabilities are stated or implied and this warranty in no event covers incidental or consequential  damages  injuries or costs resulting from any such defective product s     The use of NTN SNR product s  implies the acceptance of our warranty conditions  Modifications to our standard warranty  must be in made in writing and approved by NTN SNR Roulements     Siege social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 9    www ntn snr com       18  DECLARATION OF CONFORMITY    DECLARATION OF COMPLIANCE WITH STANDARDS    NTN SNR Roulements  registered in Annecy  
13. d and ensure that all power is  removed     The electrical connection should be carried out by an electrician who has understood and identified the various connectors  and wiring that has been selected for the system  operating voltage  connector types  remote control  cycle sensors      Connect the pump to the power supply using the appropriate power connector  refer to 7 7 1 Connector types  again  ensuring they are suitable for the selected voltage and frequency  The power cable should be adequately chosen to  ensure it can handle the current at the specified voltage    On 110V 230VAC versions it is strongly recommended that a 1A fuse T and a differential trip is installed with an activation  level of 30 mA at 1 millisecond max  Isolation capability should be   10kV minimum and nominal current 2 4Amps     7 7 1 CONNECTOR TYPES  110V 230 V  50Hz   60Hz VERSIONS         Automatic version    Standard version    Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 7    www ntn snr com    erth       Fuse T 1A Fusa T 1A    eat i  110VAC D 230VAC dE        WAC         Wiring MINIMUM LEVEL    Automatic version manual version       Remote Control LAMP      Lamp  REMOTE CONTROL  Comman    COMMON       POWER LAMP OPTIONAL  230 Vac 12Vdc  3A max  0039433  110 Vac 12Vdc  3A max  0039433    Electric connetion    Connector Nominal voltage i a Max  A  cable    A  av      e   ev   4   osm        m  aov   a   osme
14. e set using the built in timer or counting external inputs  the two condition work with   every combinations    2  PULSE Lube Cycle and Pause cycle are determined by external inputs  During of Lube Cycle  the cycle sensor can  be monitored to ensure a correct system working  Pump can suspend the lube cycle if external pulses are  not found    3  OFF  Pump works as slave regarding the control of the machine     The MULTIPULSE AC pump has been designed in order to integrate quickly Lubso distributors elements   Programming instructions can be found in chapter 8 of this manual     6 2 MINIMUM LEVEL   In manual version  no control board  the minimum level switch  Normally closed  opens when the minimum level  is reached  With the automatic  controlled  version  a voltage free changeover contact NC NA can be obtained to give  a remote signal of minimum level     6 3 CONNECTIONS 8 WIRING  A connector plate and wiring is available as standard  lt is also possible to select another connector plate  consult  NTN SNR Roulements      Siege social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 5    www ntn snr com       7  UNPACKING AND INSTALLING    7 1 UNPACKING   Once a suitable installation position has been identified  unpack the pump and prepare for installation  It is important to  inspect the pump to ensure that there has been no damage during transportation  The packaging material used does not  require any sp
15. ecial disposal procedures  You should refer to you regional requirements     7 2 INSTALLING THE CONNECTOR BASEPLATE  A base plate is delivered with the pump  See drawing chapter 7 7 1       7 3 INSTALLING THE PUMP    e In the box there is a mounting hole template as shown in the diagram here above       162 N  This can be used to drill the fixing holes  The fixing holes should be  9mm ao     80 35 inch   Use 3 screws to fix the pump into place  O   e Locate the pump so that the filling point and the control panel are accessible   e A    by the user  x   e Allow 100mm  4 inches  perimeter distance around the pump for easy access   gt  IT   e Ideally  install the pump at a height that is easily and comfortably accessible    by the user to facilitate maintenance and refilling  o    e Do not install the pump where it may be submerged by liquids of in excessively  aggressive environment      e Do not install the pump in hazardous areas where there may be flammable or    dl  explosive materials    e Do not install near strong heat sources or electrical areas that may cause electrical interference with the control system    e Ensure that tubing and wiring is appropriately secured and protected     7 4 INSTALLING PUMPING ELEMENTS   The MULTI   PULSE AC pump is supplied with a single pumping element installed in Port 1    Additional pumping elements can be installed on any of the additional pump port  2 or 3   It is also possible to move the  pumping element 1 to another port if neces
16. ess the PRELUBE option is set     When powering on the system or when pressing the RESET button the display will the  firmware version of the unit for 2 seconds    For all modes the Prelube parameter determines if the pump starts in a lubrication cycle when  it is set to ON    Cycle and Pause inputs consider one complete cycle when the input returns to its original  state at the time of cycle  For example  if the switch is in the ON state at the start of the  lubrication cycle then it must change state to OFF  and then back to ON to count as one cycle     SPECIAL FUNCTIONS AND PARAMETERS  STEP BUTTONS DESCRIPTION     ox  hold for 5 seconds Enter programming mode  Select PARAMETER to change    Increment Decrement VALUE SETTING of PARAMETER  Confirm value setting and return to menu   ox  hold for 2 5 seconds Save settings and exit programming mode       DE a ee  Ia      KM    Siege social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 2    www ntn snr com       NOTE   To modify the operating parameters repeats steps 2 to 5 for all necessary values and  then follow step 6 to save and exit    During programming mode  if no button is pressed for 20 seconds  or alternatively UP  or DOWN arrows are held for 2 5 seconds  this will exit Programming mode without saving  the values     SPECIAL FUNCTIONS AND PARAMETERS    BUTTONS DISPLAY DESCRIPTION  Release  rese     Reset to default parameters for the current OPERA
17. h during its operation and during maintenance operations    The panel  and any accessories mounted on it  should be carefully checked immediately on receipt and in the event  of any discrepancy or complaint the NTN SNR Roulements Sales department should be contacted without delay   NTN SNR Roulements declines to accept any responsibility for injuries to persons or damage to property in the event  of the non observance of the information presented in this manual    Any modification to component parts of the system or the different destination of use of this system or its parts without  prior written authorization from NTN SNR Roulements will absolve the latter from any responsibility for injury to persons  and or damage to property and will release them from all obligations arising from the guarantee     3  GENERAL DESCRIPTION    3 1 CENTRALIZED LUBRICATION     GENERAL OPERATING INFORMATION   Centralized lubrication systems are designed to provide oil or grease to lubricating points on industrial or mobile  machinery  Such systems considerably reduce the cost of maintaining machinery on which they are installed  eliminating  machinery downtime caused by poor lubrication as well as prolonging the life of the machinery in general    Additionally  a centralized lubrication system allows difficult to reach lubrication points to be lubricated at frequent intervals  that would otherwise be hard to access under normal conditions     Si  ge social   NTN SNR ROULEMENTS   Rue des Usines
18. he following operations should be performed on the pump     Mm Frequeney   Operation    Integrity of tubing After initial 500 hours  Check fittings and tubing secured     and system Every1500 hours  Verify components are correctly fixed to machine     Top up level with clean lubricant  Filling Filter As needed  or once per year Check and replace as necessary       Siege social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 6    www ntn snr com       11  DISPOSAL    During maintenance or disposal of the machine care should be taken to properly dispose of environmentally sensitive  items such as oils or other lubricants  Refer to local regulations in force in your area  When disposing of this unit it is  important to ensure that the identification label and all the other relative documents are also destroyed     12  SPARE PARTS    OPTION       13  DIMENSIONS    Grease version       Dimensions in mm  in      Oil version       Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 7    www ntn snr com       14  HANDLING AND TRANSPORTATION    Prior to shipping  the equipment is carefully packed in cardboard package  During transportation and storage  always  maintain the pump the right way up as indicated on the box  On receipt check that package has not been damaged  Then   store the machine in a dry location     15  OPERATING HAZAR
19. ling system  PULSE  If OFF  to expiring of the pause time   stars the lubrication cycle   If ON  to expiring of the pause time  STOLE on OFF  gives Pause Time Overrun alarm   NOTE      Continuous Cycle  Continuous cycle can be achieved by setting the pause timer to zero   Complete cycle  Valid on input full cycle ON gt OFF gt ON or OFF gt ON gt OFF    Both  When the pause timer is set to non zero  the system operates in a combined mode   The cycle will start EITHER on impulse Count OR Pause Time being reached     a       Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 1 4    www ntn snr com       9  TROUBLESHOOTING    Below is a trouble shooting table to show possible problems and solutions   If you are in any doubt about the correct solution to fix a problem  do not dismantle parts of the MULTI PULSE AC  but contact NTN SNR Experts     Tools for technical assistance     Troubleshooting table    Fe sens the power lines  ensure that any fuse installed is  Fe sens intact    Pump Motor does not Electronic Controller does not Replace electronics board  operate function  Gear motor no longer works Replace gear motor assembly    Check the condition of tubing in the system and ensure  Tubing is disconnected that it is correctly secured and not blocked for example   Pump is operating but no by hardened grease     lubricant reachespoints  Distributor valves are blocked Clean or replace     Eee  vane S A
20. lubricant   Continue to fill unit until the max level is reached  this level should not be exceed  In the event the user overfills the tank   the excess lubricant will be expelled through vent holes located under the lid     GREASE version OIL version          Oil Filler Cap    Grease Filling Point    PTE      SOM ma       WARNING  To avoid introducing contamination into the pump and voiding the warranty  ensure that refilling is always carried out through the designated ports using clean grease   Refer to 15 for more information about lubricant characteristics     Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 9    www ntn snr com       8 4 CONFIGURATION    Automatic version  Control panel layout    NTN  ENS        DISPLAY  Indicates the parameter  being programmed and          the set value RESET  a 9 Resets the current lube cycle   OK multi OU Ise cancels any alarms and restarts  Confirme la valeur ANN the program   affich  e before openning  UP ARROW       O Q     Allows the user to increment lub solutions www ntn snr com DOWN ARROW  the setting value shown Allows the user to decrease   on the display the value shown on the display    Optional Remote Light Button    The light is constantly lit when the pump is running    Flashes when a minimum level or other alarm is detected by the control system in the pump  The number of flashes  defines the anomaly code    When pressed during the pause
21. mp  and lubrication cycle or a manual version where the pump motor is controller externally by applying and removing power   The main body of the pump is made from high performance robust plastic and is compact in size designed to withstand  tough environments    The grease version of the MULTI PULSE AC includes a stirrer device with a reservoir wiper that help to eliminate air  present in the grease and facilitate pumping even at lower temperatures     4  PRODUCT IDENTIFICATION    On the side of the pump there is a label that indicates part number of the product  operating voltage and basic  characteristics     LUBSO PUMPING ELEMENT AC Pumpinp element  6mm with PSV integrated       Kit to assemble the distributor  AMI API onto the MULTPPULSE AC 110 230V pump    Siege social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 3    www ntn snr com       9  TECHNICAL CHARACTERISTICS    General technical characteristics    Operating voltage ne  110 V 110 V 230 V   Current  nominal  0 2 A 0 1      Current  peak    Net weight with 5 Liter reservoir 7 kg  15 43 Ib    2 8 ommin  0 17 inmin    20 RPM    Working pressure 280 bar  4061 psi     Integrated By pass pressure  for pumping elements with    integrated PSV  320 bar   30 bar  4641 psi   435 psi     Max grease consistency    Humidity 90    IP Protection level IP 65  Noise level  lt  70 dB  A   Control panel characteristics  Operating Voltage NE Includes internal tr
22. our  Internet website www ntn snr com          Bringing you a complete tools and services solution for your bearings  suited to your  application  size and resources        Experts              Tools       Siege social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072 N   N  SNR      Code APE   Code NACE 28 15 21       www ntn snr com    
23. right to update the product and or the user and maintenance manual without the obligation  to revise previous versions Further copies of this manual  updates or clarifications can be obtained by directly contacting  Experts  amp  Tools at NTN SNR Roulements  or to consult our web site at www ntn snr com    The use of the equipment referred to in this manual must be entrusted to qualified personnel with a basic knowledge  of mechanics  hydraulics and electrical systems    It is the responsibility of the installer to use tubing suitable for the system  the use of inadequate tubing can cause  problems with the pump  injury to persons and create pollution    Loosening of connections can cause serious safety problems  carry out a check before and after installation and   if necessary retighten them    Never exceed the maximum working pressure values permitted for the panel and the components connected to it   Before any maintenance or cleaning operation disconnect the power supply  close off the airsupply and discharge  the pressure from inside the equipment and the tubing connected to it    Do not subject the panel  the connections  the tubing or parts under pressure to violent impacts  damaged tubing  or connections are dangerous and should be immediately replaced    After long periods of inactivity check air tightness of all parts subjected to pressure    Personnel must use personal protection equipment  clothing and tools adequate for the location and the use of the panel  bot
24. rue des Usines   CERTIFIES    that the machine MULTI PULSE AC pump     has been constructed in conformity with the DIRECTIVES OF THE COUNCIL OF THE EUROPEAN  COMMUNITY on the standardization of the legislations of member states       2004 108 Electromagnetic compatibility     2006 42 Machinery Directive    2006 95 Low voltage    Annecy  July 2010    NTN SNR Roulements    Christophe Oddoux  Christophe Benier   General Manager Experts  amp  Tools Product Manager Experts  amp  Tools       Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 20    www ntn snr com       Web site  http   www ntn snr com   E mail  expertsandtools ntnsnr com    LUB SOLUTIONS   The Products and Services offer designed to bring you lubrication  solutions  Specifically selected for your different applications  a choice of lubricants is offered  as well as a full range of reliable systems to dispense them with precision on each mechanical  organ     LUB SOLUTIONS are above all experts to support you while setting up lubrication systems  adapted to your environment  From advices to specify your needs to the implementation of  your lubrication system  including their manufacturing  rely on our experts to bring you the  right solution     Experts  amp  Tools offer also maintenance tools  specifically designed for bearing fitting and  removal    Should you require more info  please ask for our  Maintenance tool catalogue  or visit 
25. sary  to simplify piping arrangements on the lubrication system  To install a  new pumping element    e Unscrew and remove the plastic plug with the O Ring that is installed on the standard product    e Insert and screw the pumping element until it is fixed in position    e Use 20Nm torque to secure the element     WARNING  Based on the position of the internal cam drive it may be difficult to screw in the  pumping element as it compresses the return spring  In this case  use another outlet or of pay  particular attention when inserting the pump element and ensure that it does not cross thread     Si  ge social   NTN SNR ROULEMENTS   Rue des Usines   74000 Annecy   FRANCE   RCS Annecy B 325 821 072  Code APE   Code NACE 28 15 6    www ntn snr com       7 5 HYDRAULIC CONNECTIONS   The hydraulic connection to the pump is via the pump outlets using adequate 1 4BSP fitting and tubing    Additionally there is a 1 8    BSP port that can be used as a return line or a remote refilling line  Ensure that any refilling  system provides clean grease to the pump     7 6 INSTALLING THE LUBSO DISTRIBUTOR DIVIDER VALVE   Under the base of the pump it is possible to install a LUBSO DISTRIBUTOR   Use our kit for this purpose which contains 2 screws and a bent rigid tube   Refer to the diagram below        7 7 ELECTRICAL CONNECTIONS  amp  WIRING    CAUTION  Before carrying out any electrical wiring you should check the label on the pump  to ensure that the correct operating voltage is being use
26. ubricant  1 Flash  reservoir  The cycle sensor was not received within the specified  2 Flashes Cycle Sensor overrun   time  Ensure Timer overlong is set to approriate value  and that there is no problem on the lubrication circuit     3 Flashes Pause timer overun Verify input pause sensor  LH 4 Flashes Pump Motor Blocked Replace the motor unit  E Flashes Pump Motor Over load Allow system to cool  if the problem still goes on go on   replace the motor unit  C COU pulses counter  7 Flashes Eprom Error Electronic Board memory error   Board requires replacement     4  and y  together     10  MAINTENANCE PROCEDURE    WARNING  Before carrying out any maintenance operation  ensure that power and hydraulic    system are disconnected    The MULTIPULSE AC pump does not require any special tool for operation and maintenance  When working with the  MULTI   PULSE AC pump it is nonetheless recommended that personal health and safety equipment is used as it is normal  for any operation in an industrial or similar workplace to best safeguard the user from harm    The MULTIPULSE AC pump has been designed and built as to require minimal maintenance and operate in diverse and  challenging operating environment  It is recommend that the unit is inspected and kept clean to ensure long life and  trouble free operation  It is important to check all tubing on the system to ensure that it is always tight and leak free     NOTE    To cancel alarm message push buttons    10 1 OPERATIONAL MAINTENANCE  T
    