Home
Manual - Bio-Art
Contents
1. Bio Art Microblaster is provided with an ejecting needle made of sintered carbide which assures higher durability and accuracy during blasting Bio Art has developed three Microblaster models depending on the purpose Microblaster Standard and Lab Models One fixed nozzle mounted at a 138 angle Microblaster Plus Model Two removable and autoclavable nozzles mounted at 90 and 138 angles Attention Before operating the equipment read carefully all i instructions contained in this manual i gt 2 TECHNICAL SPECIFICATIONS EEE Weight of Microblaster Standard and Lab without the package 65g Weight of Microblaster Plus without the package ccccceeeeesseeeeeeeeeaaeees 70g Weight of Microblaster Standard and Lab with the package 210g Weight of Microblaster Plus with the packagQe ccccccsseeseeeeessseeeeeeeeeeaes 215g Package dimension W x T X H seres 190 x 133 x 50 mm Work pressure acao rasto lins tusia aid saio iaiis ii anta aieit 60 a 80 Ibf pol 4 5 5 Kgf cm Granulation of the supported aluminum oxide up to 100 microns gt 3 PACKAGE CONTENT lt When opening the package check for the presence of the following items inside according to the specified model Microblaster Standard and Lab Models 01 Microblaster with fixed nozzle and ejecting needle at 138 01 Quick coupling 2 01 Connection to equ
2. SP Brasil Tel 55 16 3371 6502 Fax 55 16 3372 5953 www bioart com br
3. and for cases when the work offers such conditions we recommend the use of the Bio Art Bio Chamber suction chamber Using Bio Art Bio Chamber suction chamber Bio Art BIO CHAMBER not included is a complementary product for use with Microblaster Manufactured by Bio art it is an exhaustion chamber used in the blasting processes with the purpose not to allow the excess of aluminum oxide and the impurities generated in the blasting process to be launched to the environment Bio Art BIO CHAMBER is provided with an exclusive exhaustion system and a blasting chamber with high visibility and exclusively designed to work with Microblaster thus providing higher cleaning speed efficiency safety and practicality in the blasting processes gt 10 WARNINGS lt Never point the ejecting needle 01 to any part of the body during the blasting process Use only abrasive of the type aluminum oxide 8 The aluminum oxide used in Microblaster might cause skin eye and respiratory tract irritation Never use Microblaster without personal protective equipment PPE Never use aluminum oxide with traces of moisture or contaminants Never use aluminum oxide with granulation out of the manufacturer s specification up to 100 Microns gt 11 SPECIAL STORAGE CONDITIONS HH Bio Art Microblaster shall be stored under the following conditions e With the clamp installed on the switch button 04 keeping it always pressed Alway
4. of abrasives nay The excess of aluminum oxide in residues recycling attempt the blasting shall be disposed Air leaking on the Na Contact the Authorized Technical Microblaster body nie inal Dune hose damaged assistance Service Air leaking through the Displacement of the driving Contact the Authorized Technical ejecting nozzle needle lever internal hose assistance Service 9 In case of clogging in the Microblaster internal pipeline a simple Retro blasting procedure might solve the problem For this purpose see the information described in item 8 Maintenance and cleaning of this user manual gt 13 SYMBOLS l sn e ree Check Instructions Authorized Representative in for Use Serial Number Model Code the European Community Mid AF Date of manufacture Manufacturer s data Attention Keep in dry place This side up Fragile Maximum piling gt 14 TERM OF WARRANTY AND AUTHORIZED TECHNICAL ASSISTANCE BIO ART Equipamentos Odontol gicos Ltda grants a six month warranty for this product starting from the date of its acquisition This warranty covers all and any manufacturing defect being provided through repair of the equipment and subjected to the following requirements That the product has been used correctly in accordance with the instructions described in the user manual The claim is accompanied by the purchase invoice and registered within the warranty period followed by a report wi
5. MicroBlaster bioart intelligent solutions USER MANUAL gt INDEX CR 1 HLLOGUIC d o q ae ee mee eve aot Careers E 2 2 Technical Specifications ccccccccsecccceececeececeeeeeseeeeessseessseessaeees 2 3 Package CONIENL einen 2 4 Main characteristics of the MOdel cccccccsececeeeeeceeeeeseeeeesseeees 3 5 Main items of the Producl u u cneunenei een 3 6 Installation WISIMUICTIONS eu re 4 7 Use INSITUCUON SS een een 5 8 Maintenance and cleaning isccusvasesinteniacwacnemsaixinseveceussasseeitensiseniwcnadies 6 9 Safety precauttonis ee RE NR ark nen RR AREA 6 10 AT Ta 9 15 Sara sento sho faia a SD sits 8 11 Special storage Eondili ns ne es 9 12 Problems and SOIUtIONS ccccecccseecceeeceseeceueeceaeeceueeceeeeeeeeseas 9 13 31 010 ene eer ee nee ee ene Gas os eer 10 14 Term of warranty and technical assistance 10 15 Authorized technical assistance erre 11 16 European authorized representative cccccccseeeeeeeeseeeeeeeees 11 gt 1 INTRODUCTION Bio Art Microblaster is a portable pneumatic device easy to install and operate designated to surface blasting mainly in dental works The use of Microblaster in dentist s offices and dental laboratories has more and more been requested for being practical ergonomic and accurate in small jobs and or where the area to be blasted has a slight contact with areas of preservation from blasting
6. ate adherence of the internal driving tube walls which might make the oxide passage difficult 2 Microblaster Plus model is provided with two removable and autoclavable nozzles 02 and 11 offering two options for the ejecting needle angling one at 90 indicated for intraoral works on posterior teeth and another at 138 indicated for laboratory works and intraoral works on anterior teeth According to the kind of work to be carried out fix one of the nozzles on the Microblaster body by means of the fixing nut 12 During the nozzles removal or fixation 02 or 11 on Microblaster Plus firmly hold the nozzle with the fingers of one hand without turning it and then turn the connecting nut with the fingers of the other hand 12 thus fixing or releasing the chosen nozzle by means of the nut thread Never use any kind of wrench or tool to fix or release the nozzle on Microblaster Plus Note Nozzle 02 used in the Microblaster models allows rotation up to 180 facilitating the performance of very different kinds of works 3 Fill the tank 06 in to maximum 4 of its capacity with aluminum oxide and fix it on the tank for abrasive lid 5 located at the end of the Microblaster body Use only abrasives of the type aluminum oxide and with granulations in the range up to 100 microns Note Bio Art commercializes the perfect aluminum oxide for consumption and refill to be used with Microblaster 4 With the tank duly filled in an
7. d introduced in Microblaster press the switch button 04 to start the blasting process Remark If the blasting is interrupted for any reason even with the switch button 04 pressed and the tank 06 filled in with abrasive follow the steps below keep the switch button 04 pressed with the other hand hold the hose firmly in the region close to the end of the Microblaster body pulling slightly and releasing immediately afterwards repeat this procedure until the air passage is free Tr 5 Always try to keep a distance from 5 to 10 mm between the face of the Microblaster needle tip 01 and the surface to be worked during blasting Important note e In order to obtain better results during the blasting works make small fast and constant movements throughout the whole surface to be blasted Some recommendations for the aluminum oxide granulation indicated for some application examples are presented below It is upon the professional s discretion to choose the best applicable granulation provided that it is supported by Microblaster up to 100 microns Applications Granulation Micro retentions surface roughness Bracket recycling cleaning Internal inlay onlay cleaning of resin and ceramics 50 microns Cleaning or degreasing of metal and or ceramics when the n a 50 microns intraoral ceramic repair technique is used Occlusal blasting for fine tuning replacing the use of carbon Internal evi
8. dencing for crown adjustment and seating Adjustment of interproximal contacts 50 microns Removal of cement from metal crowns resins ceramics and other materials 90 microns Cleaning of cast parts 90 microns Removal of oxidation 90 microns abrasion function blast without prophylaxis function i e there is no any N Bio Art Microblaster is equipment exclusively designed to produce a similarity with sodium bicarbonate blasting equipment gt 8 MAINTENANCE AND CLEANING HS Before disconnecting Microblaster from the compressed air network or the equipment remove the tank for abrasive 06 and then place your finger on the tip of the ejecting needle 01 closing the needle orifice and simultaneously press the switch button 04 for approximately three seconds for the internal hose to totally empty the abrasive that might still be in the system This process is called Retro blasting The Retro blasting procedure shall not be executed for more than five seconds which might cause breakage of the tank for abrasive 06 For the Microblaster cleaning and disinfection use only a cloth dampened with water or alcohol 70 Bio Art Microblaster shall never be sprayed with liquids be submerged or sterilized in an oven or an autoclave except for the removable nozzles 02 and 11 in the Plus model which after being released from the product can be sterilized in autoclaves Keep the compressed air network always free of moist
9. ipment 01 A tank with 40g aluminum oxide 50 microns 01 Instruction Manual Microblaster Plus Model 01 Microblaster 01 Removable nozzle with ejecting needle at 90 01 Removable nozzle with ejecting needle at 138 01 Quick coupling 01 Connection to equipment 01 A tank with 40g aluminum oxide 50 microns 01 Instruction Manual gt 4 MAIN CHARACTERISTICS OF THE MODEL lt Characteristics Standard Lab Plus Fixed nozzle with ejecting needle at 138 Removable nozzles with ejecting needles Autoclavable nozzles Use of aluminum oxide with granulation Possibility for intraoral use Exclusive use in laboratories Yes gt 5 MAIN ITEMS OF THE PRODUCT mal Microblaster Standard and Lab Models 01 Ejecting needle 02 Fixed nozzle 138 03 Microblaster Body 04 Switch button 05 Lid of the tank for abrasive 06 Tank for abrasive 07 Quick coupling for use on compressor 08 Engaging nut for fixation of the PU hose 09 Connection to equipment NICRORLAST STANDARD 10 Nut with spigot MAIN ITEMS Microblaster Plus Model 01 Ejecting needle 02 Removable nozzle 138 03 Microblaster body 04 Switch button 05 Lid of the tank for abrasive 06 Tank for abrasive 07 Quick coupling for use on compressor 08 Engaging nut for fixation of the PU hose 09 Connection to equipment 10 Nut with spigot gt 11 Removable nozzle 90 10 MICROBLASTER 12 Nut for fixation of the
10. removable nozzles 90 and 138 PLUS MAIN ITEMS gt 6 INSTALLATION INSTRUCTIONS HH The Bio Art Microblaster shall be installed by means of a nut with a spigot 10 in a pure and dry compressed air network For the equipment and the user s safety and for better performance during the blasting works make sure the compressed air pressure is kept stable at 60 to 80 Ibf inch2 4 5 5 Kgf cm Bio Art supplies the connections 07 08 and 09 together with the product aiming to facilitate their connection during installation considering that it can be connected to a standard compressed air network or to the equipment low rotation terminal as described in the illustration below COMPRESSED AIR HOSE PU 6 0 USING THE E MICROBLASTER CONNECTIONS FOR USE ON A SPIGOT COMPRESSOR COUPLING BODY FOR HOSE CONNECTION USING THE CONNECTIONS COUPLING OF NE MICROBLAST FOR USE IN EQUIPMENT i HOSE NUT WITH EQUIPMENT a CONNECTION FOR After the Microblaster installation has been finished correctly follow the use instructions and the other information about precautions and safety described below gt 7 USER INSTRUCTIONS iii 1 Remove the switch button clamp 04 When removing the switch button clamp 04 try using it immediately afterwards and always after using Microblaster return the respective A clamp to the button 04 thus keeping it always pressed The act of keeping the button clamp released for long periods might gener
11. s disconnected from the compressed air network and or the equipment e In a cool dry and free of dust place e Far from chemical products and protected from sources of heat and sun light e Preferably in its original packaging gt 12 PROBLEMS AND SOLUTIONS SE Problem Case Son Incorrect connection of Microblaster to the compressed air network Air and or abrasive Insufficient or instable See item 6 of this user manual jac compressed air and monitor the correct pressure flow missing or 60 to 80 Ibflinch 4 5 5 Kgf cm a network pressure insufficient at the ejecting needle Throttling of the driving hose 01 k k by the button lever See item 6 of this user manual and install Microblaster correctly See item 7 part 4 of this user manual Insufficient BESS of abrasive aluminum BESS in the tank 06 Presence armoire inne The compressed air network shall be dry compressed dir system Check the coalescent filter efficiency p y and the presence of moisture Fill the tank 06 in with aluminum oxide at maximum of 3 4 of its capacity The abrasive shall be free of moisture with humid weather it is necessary to pre dry in an oven or an open pot at 250 C for 30 minutes Presence of moisture in the abrasive Clogging aging Incorrect granulation out of Use only abrasive of the type aluminum oxide specification in the user up to 100 microns preferably supplied manual by Bio Art itself Reuse
12. th description of the defect and the product serial number e The product is handled transported and stored with care The transport cost round trip is paid by the customer Warranty limitations Natural wear of parts e Misuse falls or accidents e Inadequate transport Repair by non authorized personnel Use in disagreement with the device features and purposes Wear due to exposure to adverse conditions humidity cold and intense heat Damage due to lack of cleaning or maintenance with inappropriate products 10 In case of doubts contact the manufacturer BIO ART EQUIPAMENTOS ODONTOLOGICOS LTDA Rua Teot nio Vilela 120 Jardim Tangara Zip Code 13568 000 S o Carlos SP Brazil Tel 55 16 3371 6502 Fax 55 16 3372 5953 CNPJ 58 538 372 0001 State Regis 637 034 447 113 www bioart com br gt 15 AUTHORIZED TECHNICAL ASSISTANCE amp For your safety technical assistance on this product shall only be provided by authorized personnel companies See our site www bioart com br for the Authorized Technical assistance posts gt 16 EUROPEAN AUTHORIZED REPRESENTATIVE EEE OBELIS s a ec REP Boulevard G n ral Wahis 53 1030 Brussels BELGIUM Tel 32 2 732 59 54 Fax 32 2 732 60 03 E Mail mail obelis net 11 Ww bio art intelligent solutions Rev CMAN0274 e Jun 2014 Rua Teot nio Vilela 120 Jd Tangara CEP 13568 000 S o Carlos
13. ure and oil always observing the efficiency of your compressor s coalescent filters For model Microblaster Plus whenever changing the nozzles 02 and 11 carefully clean the nozzles and the fixation nut s 12 thread in order to eliminate possible aluminum oxide residues or dust and to avoid their damage or locking gt 9 SAFETY PRECAUTIONS i Intraoral Use application in laboratories Its intraoral use can be based on health safety rules and restricted to the exclusive technical responsibility of the Dental Surgeon or the responsible professional Bio Art Microblaster was developed for general use and mainly for 7 Due to the constructive features of the Microblaster Lab model its use AN shall be restricted to laboratories thus it is not indicated for intraoral procedures The Dental Surgeon or the responsible professional are fully responsible for the product use regarding the safety items the environment the operator s and the patient s personal protection indications and contra indications and side effects Bio Art denies any responsibility for any damage caused by undue use of Microblaster and in cases where the safety items described in this document have not been complied with General and laboratory use The Use of personal protective equipment PPE s when working with Bio Art Microblaster is compulsory Use protection goggles gloves and breathing mask when operating the equipment In addition to these EPI s
Download Pdf Manuals
Related Search
Related Contents
MーTSUBーSHー Tripp Lite SMART1000LCDTAA uninterruptible power supply (UPS) Ele-BOX(エレボックス) - D REAR RUN-TURN-BRAKE LIGHT BARS for TRIKES 7268 Modell-Nr. WV-SFV481/WV-SFN480 - Psn Nokia 2280 Manual do Usuário Severin KA 4489 coffee maker T'nB CSPUREGR headphone 413KB (VOL.2012.9) Copyright © All rights reserved.