1. AS 1088 4 1987 cupboard with audio equipment 5 2 Long Rooms if two loops installed Microphone E A H ll Both loop Ei E ae cables to be pee 3 in the same If conduits or oo current must flow I within 20mm in same direction of each L JI other Giese cable within 200mm of wall Ba Loop Amplifier PA Equipment Loop Amplifier S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 9 of 17 Debians max 10m Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 5 3 Large Rooms The loop should include all the auditorium area but in larger auditoria or in multiple auditoria the loop is recommended to be on one side in preference to the back or front loop amplifier amp PA equipment dimension precisely on eal om architect loop location l amp electrical dwys coordinate at design as L i well as contruction main speakers positions stages V Vo V T OE ensure suitable Iighting some ir on speakers i locations need to be etc reinforce tha verbe scaly a drew In boxes may be Av necessary for loop In conduit See AS 1428 2 cl 19 1 Lighting Maximum 200mm sat out from wall Refer for minimum arga to be covered SIGN AT ENTRY refer 4 1 LR SIGN AT FRONT refer 4 1 S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Pag
2. Associates March 2003 HEARING AUGMENTATION SYSTEMS If the Hearing Augmentation system is incorporated with the public address system ensure that the Hearing Augmentation System is automatically operated with PA announcements In public buildings there are three options readily available AFILS Audio Frequency Induction Loop System The loop is located in or around the room This is suitable for most churches lecture theatres and auditoria and is the preferred option for people with hearing impairment Generally it is also the most cost effective system It is estimated that 70 to 80 of hearing aids are fitted with a T switch However If a hearing aid lacks a T switch then a loop receiver with stetoclip or head phones are required to augment the sound level for a mild or moderately hearing impaired person The advantage of the AFILS is the need to provide receivers only for those without the T switch as both other types of systems require receivers to be provided for every user Electromagnetic signals can be affected by electronic apparatus and steel to varying degrees Electromagnetic waves also pass through walls and hence loss of privacy is possible AFILS work indoors and outdoors This is relatively cheap to provide and once installed requires minimal administrative assistance apart from periodic check for being in working order If there are other loop systems close by the problem of overlap of sound must be addressed Th
3. cable The colour identification stripe to be of a different colour to the insulation colour The loop cable resistance shall be matched to the loop amplifier and this cable shall be specified and supplied by the loop subcontractor Where a wooden floor is to be installed on a concrete floor Install the loop adjacent to and within 200mm of the perimeter walls of the room above concrete slab and below false flooring Notch flooring battens to allow loop installation Where a concrete floor is to be covered directly with the flooring Install the loop adjacent to and within 200mm of the perimeter walls of the room in the concrete slab above all steel reinforcing The loop cable shall be continuous without joints or connections The loop cable to be installed in 19mm conduit with draw in boxes located on the room perimeter walls Label wall boxes AUDIO LOOP SYSTEM The loop cable shall be wired to provide two complete consecutive turns and have a total resistance of between two and three ohms Notices Provide the international symbol for deafness in a prominent position in the room indicating that an assistive hearing device is installed The symbol to comply with AS 1428 2 symbols The size of the sign is to be a minimum of A4 Provide a notice adjacent to the amplifier detailing how the system works and the procedures for testing the system Test Devices Provide one test receiver Provide two loop recei
4. clarity The signal to noise ratio must be within prescribed limits for clarity and effectiveness A calibrated field strength tester and a loop receiver are required to for testing the AFILS Further adjustments later are rarely necessary but absolutely necessary if the PA system is modified 6 A written user manual related to the system installed is necessary It should show how to operate the system the location of loop cable its diameter and the measuring data Note 5 above 7 Building owners without a hearing loss can verify loop operation on an ongoing basis using the loop receivers provided for hearing impaired users without T switch S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 13 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 8 0 REFERENCES AND CONTACTS 8 1 Sources of Information e PrintAcall Loop information catalogue e Sensory Access Seminar by Peter Kerley Oct 2000 for Standards Australia e Paper by Ref Siegried Karg at International Congress of Hard of Hearing People Sydney Australia July 2000 courtesy of Better Hearing March 2001 e Deafness Resource Guide 2000 2001 by Deafness Resources Australia e British Standard BS 7594 1993 e Australian Standard AS1088 4 1987 e Australian Standard AS1428 1 and 1428 2 Acknowledgement and thanks also to SHHH Australia Inc Ray Piesse Peter Cianchi Andrew Stewart Gl
5. floor The loop of wire or 2 wires may rise and fall at doors or windows Loop cabling must not have steel or ferrous materials between the loop cabling and the users as the ferrous materials will shield the signal from the user Therefore the loop cabling must not be laid beneath steel reinforcing or in ceiling steel channel struts Where steel reinforcing is present or significant amounts of ferrous materials the loop shall not be wider than 10 metres 3 3 The LOOP INSTALLATION may be Loop cabling may be one or 2 wires More than 2 wires must not be used as frequency response requirements are otherwise practically unacheivable In a plastic conduit about 20mm diameter with post installation access points at corners and bends Under the skirting board Under the carpet with or without underfelt Up to 400mm below the floor surface if no ferrous materials are used in the floor construction Must not have any other electrical wiring running parallel within 200mm If electric in slab heating is installed the relationship of the loop wire s to the slab wires needs consideration Adjacent loop cables shall run in the same conduit or within 20mm of each other The size of the cable 0 5 to 2 5mm multistrand generally but sometimes a flat cable is calculated to suit the room size the cable length and the specific amplifier used to drive it Refer to Section 6 for tellers counter situations S OldServer EMA Work Ot
6. Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 AFILS AUDIO FREQUENCY INDUCTION LOOP SYSTEMS MARCH 2003 1 0 INTRODUCTION 1 1 This is a simple guide for architects and others in complying with the Building Code of Australia clause D3 7 Hearing Augmentation initiated by the late Mervyn Willoughby Thomas FRAIA Accredited Access Consultant with the ACAA and a hearing impaired architect It assumes a knowledge of building construction standards and legislation 1 2 Definitions and Names A number of terms are currently within common use within the industry to describe the Audio Induction Loop These terms include Hearing Augmentation includes Loop FM Infra Red Audio Frequency Induction Loop System AFILS Powered Audio Induction Loop System PAILS Hearing Aid Loop Audio Loop Loop Deaf Aid Loop NOT TO BE USED 1 3 The DDA Disability Discrimination Act 1992 through the BCA Building Code of Australia aims to maximise participation in community life by people with disabilities BCA Clause D3 7 applies where there is an inbuilt amplification system other than emergency warning in e Conference and meeting rooms over 100m floor area e Auditoria in Class 9b building Hearing Augmentation to not less than 15 of an auditorium e Rooms for judicial purposes e Ticket office tellers booth etc where the public are screened from the servicer e Any screen
7. Mobility Committee under the guidance of Eric Martin is in part of tribute to Mervyn s dedication and commitment to improving access especially for hearing impaired Special thanks are extended to Andrew Stewart from PrintAcall for his advice and editorial assistance in finalising this advice March 2003 S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 14 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 ATTACHMENT A OUTLINE SPECIFICATION HEARING AUGMENTATION LISTENING SYSTEM General Provide a hearing augmentation listening system for hearing impaired people in the room The hearing augmentation listening system shall be an audio frequency induction loop system consisting of a e Loop amplifier e Loop cable e Test Receiver e Loop Receivers e Other equipment as required Subcontractor The hearing augmentation listening system shall be installed by a specialist subcontractor with experience in installing audio frequency induction loop system Standards Loop Amplifier Transconductance Amplifier Output Current of 10 Amps continuous into 2 ohms Input compression of 30dB input 1dB output Balanced Microphone input with switchable phantom power Balanced Line input Output metering Bar graph for output signal Separate indication for threshold of compression Separate indication for 8 to 10dB into compress
8. OUNTERS 400x600 flexible mat with loop cable in perimeter built into bench International Ear Symbol Sign Uni directional microphone for teller Loop amplifier power point required Refer to BCA and Australian Standards for space and design Note Hearing loops for multiple tellers requirements are practicable when correctly designed and installed S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 12 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 7 0 LOOP AMPLIFIER MINIMUM REQUIREMENTS Green light to show if loop wire Is Tone adjustment but nine Sound Out of limited value for most volume hearing4mpalred Red light x Main to show switch leciric supply Is on K Oo 6 Microphone inputs and or line inputs FRONT PANEL REAR PANEL NOTES 1 Loop amplifiers must use current instead of voltage for adequate reception through out the speech range 100 Hertz to 5000 Hertz which is important for intelligibility of speech 2 Allow for ventilation of loop amplifiers 3 Loop wire s varies form 0 5mm to 2 5 mm diameter or can be a flat cable 18 mm wide to suit room size 4 The Amplifier may be fed with the signal from a wired or radio microphone or an output from a PA system 5 After correct installation of the loop system it needs checking for magnetic field strength frequency response and
9. d in the seat e Steelwork electrical cabling and some air conditioning equipment can result in unusable electromagnetic reception if not designed and installed correctly e Installers must check the system with a magnetic field strength meter to check compliance with AS1088 4 1987 and with a loop receiver to ensure the signal is distortion and interference free e Spill over control systems are also available if all of two adjacent rooms are to be looped or spill over outside a room is to be controlled S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 7 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 This is achieved by additional active loops to resolve interference However this is usually at a significant cost S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 8 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 5 0 LOOP LOCATIONS 5 1 Small Rooms 100 200 m i E O loop normally at wall face r e s air NOTE Electro magnetic sound passes through a conditioning walls brick concrete etc f fluorescent a lights Distance max 10m _ In good installations the sound level will be ES es eee uniform within the loop Checked with Loop amplifier in electro magnetic field tester per
10. e 10 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 5 4 Plan Multiple Rooms on same level Loops in adjacent areas are recommended to be on the left or right side in preference to the back or front Specialist advice is required in design to ensure spillover between loops is avoided as the minimum separation distance between loops varies according to the size and orientation of loops Care is also required when a loop is installed in the ceiling of one room under or adjacent to an area covered by loop FM or infra red on the floor above i f l l l l 1 l l l l I l 7 I i I I I l I I I t I I l I I j I I l l e E Soca A A a A SS EEE a steer ee ee Ee 5 5 Section High level loops and or metal roof or floor need greater audio power Average signal level Bie ge re N 7 15db above 80 5 _ 33 background ESE es wee S4 noise in this a A eee range Loop may rise and fall at doors windows A loop at floor or high level gives more uniform field strength at listening level However this will cause dead zones either side of the loop cable S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 11 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 6 0 BANK AND TELLER C
11. en Thurecht Eric Martin and others Many thanks 8 2 Organisations who can assist e PrintAcall 2 Doig Ave Denistone East NSW 2112 tel 02 9809 2392 e Deafness Forum of Australia 218 Northbourne Avenue Braddon ACT 2612 tel 02 6262 7808 e Deafness Resources Australia 33 Argyle Street Parramatta NSW 2150 tel 02 9895 2970 e SHHH Australia Inc Self Help for Hard of Hearing People 1334 Pacific Highway Turramurra NSW 2074 tel 02 9144 7586 e Better Hearing Australia Inc 54 Hyman Avenue Edwards Town SA 5035 tel 08 8297 3078 e Word of Mouth 27 MacAuley Place Bayswater VIC 3153 tel 03 9729 9974 8 3 Some experienced installers include e PrintAcall NSW ACT Qld Vic Andrew Stewarttel 02 9809 2392 e GPT Designs Canberra Glen Thurich tel 02 6286 9600 e Word of Mouth Melbourne Bob Willis tel 03 9729 9974 8 4 Some specialist suppliers are e Ampetronic Ltd UK for Phase Array Spill over Control e Oval Window Audio Nedland Colorado USA for 3D loop system spill over control e PrintAcall for multiple layout design systems 8 5 Outline Specification An outline specification for the design and installation of a hearing augmentation listening system is included as Attachment A NOTE This report was initially prepared by Mervyn Willoughby Thomas an ACT architect and access consultant who had a hearing impairment but unfortunately Mervyn died before he could complete this paper Its completion by ACT ACROD Access amp
12. equency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 4 2 Hearing Aids a Fora hearing aid with an electromagnetic induction T coil T switch the strongest audio reception is within the loop but there is some spill outside the loop b Hearing aids have a blind spot which needs to be considered in locating the loop The width of the blind spot either side of the cable is variable according to distance An approximate rule of thumb is 500mm either side of cable if in the floor and 1000mm either side of cable if in the ceiling tt Narrow blind zone near loop wire T coil is vertical for person in upright position for the coil to recieve the electro magnetic waves 4 3 Construction Details The loop can be located in a range of positions including those illustrated below it is important to note e No other electric wires to be parallel to loop within at least 200mm e No High Voltage wires should cross the loop area but 240V wires may cross the loop floor finish loop cable PEt eee 2 loop in conduit option loop must be above all steel reinforcement 4 4 Notes e AFILS designers installers need particular expertise and experience beyond that practised by many electrical contractors e Electromagnetic sound passes through walls e f security is required consider infra red or multiple small loud speakers i e pair of speakers for every seat mounte
13. her professional activities MWT WORK 012003 AFILS doc Page 5 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 4 0 GENERAL REQUIREMENTS 4 1 Signage Intemational Ear Symbol In white on a blue background as per AS 1426 1 Information to show what type of hearing augmentation loop FM Infrared if the loop does net cover the space the area covered should also be Indicated Indicator to Identify when there ls a signal flawing through the loop cable The indicator shall only SIGN AT ENTRY identify when a signal is present and be inactive when a signal Is not present l e Indicator only goes on when speaker is speaking and the loop amp working No light is required at the front of the room as It will ba distracting Management will need to ensure that the loop system Is malntalned and ig operational for each occasion Failure of signal to the amplifier the amplifier or the cabling shall result in the indicator failing to indicate the Audio Induction Loop System Ie working Intemational Ear Symbol In white on a blue background as per AS 1426 1 L _ Information to show what type of hearing _ gt 4 augmentation loop FM infrared If the loop does net cover the space the area abe SSE covered should also be Indicated positions S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 6 of 17 Audio Fr
14. ion Total harmonic distortion 0 5 Frequency response 3dB 100Hz gt 5kHz Min 6dB per octave roll off from 6kHz Short circuit protection Size is two rack units 2RU and allow one rack unit for ventilation Connection The input of the loop amplifier shall be connected to the line output of the public address system when a public address system is supplied by others audio out of the television when a television is supplied or expected to be supplied output of the radio microphone receivers one UHF diversity lapel radio microphone system and one UHF handheld diversity radio microphone system to be supplied by the Hearing Augmentation subcontractor when no public address system is supplied by others Location The loop amplifier shall be located in the public address system rack rack with adequate space to be provided by others where a public address system is provided The loop amplifier shall be located in a vertical wall mount cupboard vertical wall mount cupboard to be supplied by the Hearing Augmentation subcontractor when no public address system is supplied by others Loop The loop shall comprise insulated Figure 8 cable with a continuous colour S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 15 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 identification stripe along the entire length of the
15. is is a serious problem if the auditoria are next to or above one another There are various ways to resolve this overlap but consult the experts while the design is still in its early stage There are many unsatisfactory audio magnetic loop installations It is an area for the specialist rather than the average electrical consultant or contractor Consultation may be necessary at the early design stage as well as when the building is under construction Many telephone handsets have a coil which with a T switch on the hearing aid cuts out the background noise One concern when installing AFILS is interference caused by electrical cabling or in some cases nearby electronic electrical equipment FM Frequency Modulation This system consists of a base station transmitter and individual receivers for each user Attachments are also required for each user neck loops for users with T switch on their hearing aids and headphones or stetoclip for the remainder of users For lecture tours the same receivers and attachments are used but with a personal transmitter with lapel microphone The Phonic Ear Easy Listener is an example of both the above systems it is found in some public galleries and museums where the battery units can be recharged overnight In FM systems radio waves pass through walls Hence loss of privacy is possible FM systems may be used both indoors and outdoors S OldServer EMA Work Other professional activitie
16. nal trying to be heard Reverberation typically becomes an impediment to understanding if the hearing impaired person is greater than 1 5 metres than the sound source although the exact distance varies between individuals and circumstances Hence loop systems are commonly used in lounge rooms to assist in understanding the television This is a clear example of the needs of hearing impaired people for Hearing Augmentation For an effective AFILS system the aim is to minimise the distance between the source of sound and the listener The signal received by a hearing impaired person needs to be greater than 15 dB above the background noise level i e Signal to noise ratio S N gt 15dB 1 6 A hearing impaired person can hear sounds but their ears lose the faculty of e Distinguishing the message of a specific speaker from the background noise level e Understanding the words due to reflections of the sound off walls floors furnishings etc e The ability to cope with changes in level of sound i e dynamic range The spoken work still needs to be clearly enunciated and not too fast Seeing the expression on a speaker s face and body language is important as many use a combination of hearing and lip reading to reinforce the spoken message S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 2 of 17 2 0 2 1 2 2 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and
17. o AS1428 1 at the entry of the room and at the front of the room S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 17 of 17
18. or scoreboard capable of displaying public announcements must supplement any public address system eg captions Refer to the BCA for the precise text 1 4 The intent of this paper is to clarify some of the options which realistically meet the BCA requirements for hearing augmentation for the majority of hearing impaired people 1 5 Hearing impairment which occurs to many people especially if over 50 years age can be mild moderate severe or profound Augmentation of sound will not help all of the profoundly deaf as some have no hearing they need subtitles or captions People with hearing impairment may try to compensate by using a hearing aid cochlear implant or a loop receiver If the hearing aid or cochlear implant has a T switch and the room has an audio loop correctly installed and picking up sound from the microphone of a specific speaker or sound source whether wired or radio then the background noise can be reduced or eliminated A loop receiver is a pocket sized device fitted with a T switch and stethoscope style earpieces called a stetoclip S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 1 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 There are two types of background noise The first is noise other than the signal trying to be heard e g air conditioning audience chatter The second type is reverberation of the sig
19. s MWT WORK 012003 AFILS doc Page 3 of 17 2 3 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 If there are loop systems close by the problem of overlap of sound must be addressed There are various ways to resolve this overlap but consult the experts while the design is still in its early stage IR Infra Red Infra red listening systems require a special headphone receiver and requires clear path from transmitter to receiver i e line of sight unobstructed by people s limbs and objects even by paper Attachments are also required for each user neck loops for users with T switch on their hearing aids and headphones or stetoclip for the remainder of users Alternatively different type of receivers may be used to achieve the same result Walls are a barrier and hence privacy is assured IR is not suitable outdoors as sunlight disrupts the infra red signal nor is IR suitable in rooms with direct sunlight As with AFILS IR is commonly used for hearing the television and radio in the home In public buildings IR is rarely used except where privacy is absolutely necessary due to the large radiators required rooms more than 6 metres long line of sight restrictions and cost effectiveness compared to the alternatives If there are loop systems close by the problem of overlap of sound must be addressed There are various ways to resolve this overlap but consult the exper
20. ts while the design is still in its early stage S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 4 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 3 0 THE AUDIO LOOP INSTALLATION 3 1 The aim of AFILS is to obtain Reasonable magnetic field strength within the working area at ear level 1 metre sitting 1 7 metre standing per AS1088 4 1987 Minimal overspill which could cause interference with other similar systems or compromise confidentiality Acceptably uniform magnetic field strength over frequency range 100Hz to 5000Hz per AS1088 4 1987 To achieve this current amplifiers not voltage amplifiers must be used in order to obtain uniform field strength at all frequencies in the speech band Thus public address amplifiers and wiring circuits are not suitable for AFILS Adequate signal processing to achieve compression limiting so that the variation in output level is less than 3 dB for a variation of input signal of 30 dB Adequate loop receivers for users without T switch Coverage over all classes of seating 3 2 The LOCATION in a room or area may be Around the perimeter of the listeners ensuring the cable is more than 0 75 metres outside the listening area as the signal from the cabling will not be picked up directly above or below the cable At floor level up to three metres above floor level or just under the
21. vers for hearing impaired users with hearing aids The number to be supplied is five percent of the maximum number of people to be in the looped area at one time Loop receivers are to be supplied with one stetoclip with each receiver Provide Training and Instruction Manual Provide staff training to make staff aware of how the system works and the need to have it turned on and tested regularly Testing and Commissioning Carry out a commissioning with a hearing aid to test clarity of soeech music and for interference at the weakest point Check field strength with a calibrated field strength meter to be a minimum of 0 1 A m with the output current as a 1 kHz sinusoidal wave and measured in the weakest place inside the loop Check loop current for compliance with the frequency response of 100Hz 5kHz and roll off of at a minimum of 6dB per octave above 6kHz Check compression of 30 dB and that the threshold of compression is set for soft speech A procedure for routinely testing and monitoring using a loop receiver shall be detailed and staff trained in its use The procedure shall include testing the level of the loop system and listening to the clarity of speech and music through the system S OldServer EMA Work Other professional activities MWT WORK 012003 AFILS doc Page 16 of 17 Audio Frequency Induction Loop Systems Mervyn Willoughby Thomas Eric Martin and Associates March 2003 Signage Supply and install signage t
Download Pdf Manuals
Related Search
Related Contents
Motion Controller User`s Manual Extra-ordinary General Meeting Notice held on 19-May-2014 Student Guide - Inside Scripps MANUAL DE INSTRUÇÕES Fiche technique Bona Oil 25 SRX Manual, v.5.023 Samsung AW07LFABA User Manual OneTouch® Verio™ User Guide Australia English THE DEVELOPMENT OF SITUATIONAL SIMULATION GAME Copyright © All rights reserved.