Home

LOKUS K - Standalone controller

image

Contents

1. 1 and Enter the new user code and press Again e nter the new user code and press 1 User code is now registered and with it you can open output on the controller If the code has already been registered it is now deleted Next code or card you register will take the first empty position in the system Function 2 Pulse time Duration of active output or toggle mode Set the duration of active output the time in which you can open door or set output to toggle mode Toggle mode means if the user card is registered output will remain opened if it was closed or closed if it was open till next registration Set the duration of active output Enter the master code and press Press 2 and Enter the duration of active output in seconds max 10 seconds and press a Set toggle mode Enter the master code and press Press 2 and Press 0 and e Function 3 Door status switch input Set the time till the pre alarm time for which door can stay open without triggering the pre alarm and consequently the alarm This function is used when the door status switch on el strike is connected to InputO IO wire 5 on the controller Setup Enter the master code and press Press 3 and Enter the duration of time till pre alarm in seconds max 10 seconds and presse Black line Q Switch from Wiegand 26 bit to controller Right after turning the power supply on when the controller has both LEDs lit approach a user c
2. 26 bit reader and will delete everything 2 beep If you approach a user card after 2 beeps all data will be deleted The controller will be reset to default 5 2014 www codeks eu LOKUS K Standalone controller Switch from Wiegand 26 bit to controller Right after turning the power supply on when the controller has both LEDs lit approach a user card and remove it after 9 beeps Function 13 Delete all Reset delete all data to default Setup Approach the master card and remove it after 13 double beeps Within a period of three seconds approach a user card This will delete all data and reset the controller to default settings The controller will confirm this with a long beep followed by a double beep Programming Lokus with the master code The default master code is 1234 The maximum code length is 6 digits The master code must be CHANGED for security reasons because the default one is written in controller s manual and with it anybody can set himself his own code to open YOUR door PROGRAMMING FUNCTIONS WITH MASTER CODE Function 4 Pre alarm and alarm Set the pre alarm time This is the time in which the controller with short beeps alerts you that door was left open If you don t close the door in the pre alarm time the alarm will be triggered and signaled with long beeps by the controller Setup Enter the master code and press Press 4 and Enter the duration of pre alarm time in seconds max 10
3. seconds and presse Function 5 Negate switch output state This function is used when you connect an electric strike or electric magnet which needs power supply to remain in locked state Turn on the negated output Enter the master code and press Press 5 and For confirmation press 1 and The output state will be switched from the current one Function 9 Wiegand 26 bit Switch between the controller and Wiegand 26 bit reader When you switch the controller on it beeps twice in the controller mode and once in the Wiegand 26 bit mode Function Description i i 0 Change master code Switch to Wiegand 26 bit 1 Register or delete user codes Enter the master code and press Press 9 ande Press 2 Pulse time Duration of active output or toggle mode a 3 Door emer switch input time till pre alarm 1 and lt The controller will switch to Wiegand 26 bit reader and will delete everything 2 and The controller will delete all data and reset to default A Pre alarm and alarm duration of pre alarm Negate output 9 Switch to Wiegand 26 bit Delete all Function 0 Master code Change the master code Setup Enter the default master code and press Press 0 and Enter the new master code and press Again enter the new master code and press Store the master code in a secure place Function 1 User codes Register or delete user codes Setup Enter the master code and press Press
4. ING The entire set up procedure is carried out with the master card or code The master card and code cannot be replaced or duplicated After registration the master card and code should always be kept in a secure place You cannot change any setting without them and neither can we Keep that in mind when storing the master card and code Programming Lokus with the master card First connection to the power supply and registration of the master card Turn the power supply on 2 beeps indicate power on and approach a card you wish to be the master card 3 beeps indicate a successful registration The first card registered becomes the master card All the other cards will be registered as users user cards Usage of master card If you hold the master card in front of the controller every two seconds a double beep is heard The number of double beeps indicates the programming function PROGRAMMING FUNCTIONS WITH MASTER CARD Function Description Pre alarm and alarm duration of pre alarm Negate output Delete a lost card Switch to Wiegand 26 bit Delete all 5 Negate output SSS O 6 Delete a lost card o oS a Function 1 User cards Register or delete user cards Setup Approach the master card and remove it after 1 double beep Within a period of three seconds approach a user card The user card is now registered and with it you can open output on the controller If the card has already been registered it
5. LOKUS K Standalone controller LOKUS K STANDALONE CONTROLLER The Lokus is a controller with built in proximity card reader and keypad It is designed for residential and business buildings shops etc In various operation modes the controller allows access for up to 69 users 1 master card amp code and 69 user cards or codes The entire set up procedure is carried out with master card or master code User cards and codes can either be registered or deleted The controller signals normal operation with flashing red and green LED It can also be used as a Wiegand 26 bit reader TECHNICAL DATA LOKUS K Reading frequenc Reading distance Current consumption Operating voltage Operating temperature Protection Memor Push button Outputs Cabel Dimensions mm Keypad Numeric illuminated with gold plated contacts CONNECTION CABLE Wire Color pe ao eae Specification 9 14V DC Max 0 5A Not connected Data 1 Active GND Door status switch input l LED DIODES Color Description Flashing red green Normal mode El strike is unlocked Card or code has no rights Power supply The controller needs external power supply to operate The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes or two 12V magnetic locks 0 5A If you use the controller and low consumption electric strike 0 25A you can use power supply Spider W5 Black line Q Voltage drops and cable si
6. ard and remove it after 9 beeps Function 13 Delete all Reset delete all data to default Enter the master code and press Press 13 and For confirmation press 1 and This will delete all data and reset the controller to default settings The controller will confirm this with a long beep followed by a double beep Default settings A three second pulse five second open time four second pre alarm time door switch and push button have NO contact output is set for fail secure el strike The controller is in standalone mode Default master code is 1234 ORDERING CODES LOKUS box card Box K Card 1 reading frequency 125kHz cards Code Specification LOKUS K 1 Standalone controller in K box Frequency 125kHz OTHER Warranty only applies when the Lokus controller is powered with the power supply form the Spider family Please read through our warranty and disclaimer statements Connection scheme and additional support for the use of this product can be found on http www jantar si forum en CONTACT Jantar d o o Kranjska cesta 24 4202 Naklo web www codeks eu SLOVENIA mail sales jantar si 5 2014 www codeks eu
7. ations so that you can find the card or code which was registered before the lost one Setup Approach the master card and remove it after 6 double beeps Within a period of three seconds approach the user card which was registered before the lost one This will delete the lost user card Next registered card or code will take the position of a deleted card Function 7 Delete a lost card Delete the previous card on the list Use this function if you lost a card and you wish to delete it from the controller In order to use this function you must maintain a list of registered cards and codes so that you can find the card or code which was registered after the lost one Setup Approach the master card and remove it after 7 double beeps Within a period of three seconds approach the user card which was registered after the lost one This will delete the lost user card Next registered card or code will take the position of a deleted card Function 9 Switch to Wiegand 26 bit Switch between the controller and Wiegand 26 bit reader When you switch the controller on it beeps twice in the controller mode and once in the Wiegand 26 bit mode Switch to Wiegand 26 bit Approach the master card and remove it after 9 double beeps The controller will start to beep every second Each beep presents different function which is selected with a user card 1 beep If you approach a user card after 1 beep the controller will switch to Wiegand
8. gnal interferences When you connect the controller use cable with a diameter of at least 0 22mm If the cable length exceeds 25m use one twisted pair of UTP cables for the positive pole and one for the negative pole The cable length between the power supply and controller should not exceed 50m Take into consideration that a 0 22mm cable has a resistance of approximately 9 ohm per 100m The power supply at the end of cable should be a minimum of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greater distances a thicker cable of 0 5mm7 or more should be used wherever possible If the load is for example 0 5A with el strike then on the 0 22mm cable voltage drop will be 4 5V at 100m For the device with 60mA consumption the voltage drop is 0 5V Reading distance depends on where the controller is installed The presence of metal or interferences can significantly reduce reading distance It is not recommended to install controllers closer than 30cm from each other in any direction Otherwise it may result in inaccurate readings or indeed in the controller not reading at all Installation of Lokus K Remove black plastic screw covers on the top and the bottom of the controller Install the controller to the wall with two supplied screws Use diagonal holes it enables a small correction of the position of the controller up down left right When the controlle
9. is now deleted and its position is now empty Next registered card will take the first available position on the list or position of the deleted card To delete a lost user card you must maintain a list of registered cards and codes arranged in order of registrations positions Function 2 Pulse time Duration of active output or toggle mode Set the duration of active output the time in which you can open door or set output to toggle mode Toggle mode means if the user card is registered output will remain opened if it was closed or closed if it was open till next registration Set the duration of active output Approach the master card and remove it after 2 double beeps The controller will start to beep every second Each beep indicates 1 second of active output Duration of active output can be max 10 seconds When you hear the required number of beeps approach a user card for confirmation Set toggle mode Approach the master card and remove it after 2 double beeps Approach a user card before the first beep Toggle mode is selected Black line Q Function 3 Door status switch input Set the time till pre alarm time in which the door can stay open without triggering the pre alarm and consequently the alarm This function is used when the door status switch on el strike is connected to Input0 I0 wire 5 on the controller Setup Approach the master card and remove it after 3 double beeps The controller will s
10. r is installed put the screw covers back on Inputs outputs and environment Inputs Inputs are realized with opto isolators The input is active when pulled to Ground with an open collector transistor or mechanical switch which is connecting the input pin of the controller to the Ground Outputs Output has a pre installed protection diode for inductive load It is also protected from current overload The best way is to use a 0 25A el strike or a 0 5A el magnet which has to be connected to the same positive pole as the controller Connect the negative pole to the door strike output wire 3 When the output is active it is pulled to ground This can be changed with function 5 negate output for el magnet Environment The controller has IP65 protection but you must assure good cable joints protected against moisture otherwise corrosion may damage the controller Damage in such cases is not covered by the warranty Lokus K 1 reading range The controller has a program algorithm that at power start sets parameters based on the installation environment so as to ensure an optimal reading range DO NOT install the controller directly on metal surfaces and or cover it with a metal cover it may stop working reading If you plan to test the controller and move it onto different surfaces then you have to reset it power off on on each surface 5 2014 www codeks eu LOKUS K Standalone controller PROGRAMM
11. tart to beep every second Each beep indicates 1 second till pre alarm Duration of the time till pre alarm can be max 10 seconds When you hear the required number of beeps approach a user card for confirmation Function 4 Pre alarm and alarm duration of pre alarm Set the pre alarm time This is the time in which the controller with short beeps alerts you that the door was left open If you don t close the door in the pre alarm time the alarm will be triggered and signaled with long beeps by the controller Setup Approach the master card and remove it after 4 double beeps The controller will start to beep every second Each beep indicates 1 second of the pre alarm time Duration of the pre alarm time can be max 10 seconds When you hear the required number of beeps approach a user card for confirmation Function 5 Negate switch output state This function is used when you connect an electric strike or electric magnet which needs power supply to remain in locked state Setup Approach the master card and remove it after 5 double beeps Within a period of three seconds approach a user card for confirmation The output state will be switched from the current one Function 6 Delete a lost card Delete the next card on the list Use this function if you lost a card and you wish to delete it from the controller In order to use this function you must maintain a list of registered cards and codes arranged by order of registr