Home

XG2330 E1/Datacom Transmission Analyzer

image

Contents

1. Main Features e Handheld design easy to use e Full featured measurements to E1 Datacom and unique IP PING testing from Datacom e High resolution large color touchscreen e Smart navigation mode display e Extensive error and alarm generation detection and indication e Up to 99 days continuous test performance e Save Recall up to 10 user defined configurations and 10 groups of results e Built in Li ion rechargeable batteries and AC Power supply as well e Test results uploaded conserved and printed by TestManagerPro software via USB interface connected to PC erecom xX6CXC Ei XG2330 El Datacom Transmission Analyzer DATASHEET Flexible combination and comprehensive analysis XG2330 is a powerful handheld instrument providing a scalable future proof solution for testing 2Mb s and Nx64kb s digital circuits Through the easy to download testing options XG2330 offers full featured measurements of error alarm signaling tone and timeslot data and helps to verify quality of service in your networks It can be widely used in the R amp D production installation verification and maintenance of SDH PDH PCM DTU and Data protocol converter equipments Basic Functions E1 Testing e 120Q balance and 75Q unbalance line interfaces e HDB3 and AMI line codes e Out of service framed and unframed testing V 2Mb s Nx64Kb s BER testing V Frame data and alarm monitoring V Clock slip measurement In service fra
2. 18 100kHz e Hit seconds and hit free seconds counts Option 2 Datacom Testing e Datacom V 24 V 35 V 36 X 21 RS 449 RS 485 EIA 530 and EIA 530A BER testing e Asynchronous BER testing with baud rate 50b s 57 6b s e Synchronous BER testing with data rate 1 2kb s 2048kb s e DTE or DCE equipment emulation e Synchronous clock source selectable e Frequency measurement e Handshaking signals control and monitoring Option 3 G 703 64kb s CO Testing e G 703 64kb s Codirectional BER testing e Octet timing control and monitoring e Frequency and offset measurement e Transmit clock source Internal and Interface Option 4 Mux amp Demux Testing e El Datacom synchronous 64kb s Nx64kb s BER testing e E1 G 703 CO synchronous 64kb s BER testing e Frequency and Offset measurement of Rx interface e Handshaking signals monitoring of Datacom interface e El framed data and alarm monitoring Option 5 Drop amp Insert Testing e Insert mode Insert synchronous 64k Nx64kb s data from Datacom or G 703 CO interface to one or more timeslots of E1 signal e Drop mode Drop one or more timeslots data from E1 signal to Datacom or G 703 CO interface e Insert Drop mode Insert and drop one or more E1 timeslots data from or to Datacom or G 703 CO interface Specifications 1 El Testing Delay Measurement Accuracy l us Internal Clock 2048Kb s 10ppm G 703 64kb s CO Testing Line Rate Frequenc
3. amp Insert Testing optional For more information or a directory from sales offices please send inquiry to mail address sales xgxc com LALIT i IALITY MANAGEMENT f 2013 XGXC All rights reserved All product and company names are trademarks of their corporations Specifications terms and conditions are subject to change without notice Wwww xgxc com
4. Battery Li ion battery continuous working for 4 hours Recharge Time Approx 2 hours Power Supply AC Adapter Input 100V 240VAC 50 60Hz Output 12VDC 1 5A Battery Li ion battery TestManagerPro Software Operating System WIN98 ME 2000 NT XP Operating Temperature 0 C 50 C Storage Temperature 30 70 C Humidity 5 95 non condensing Dimensions 240mm x 102mm x55mm LxWxH Weight Approx 750g Telecom Configurations E1 Datacom Transmission Analyzer lset AC Power Adaptor lpcs E1 75Q Unbalanced Test Cable 2pcs El 120Q Balanced Test Cable lpcs Li ion Rechargeable Battery Built in lpcs USB Communication Cable lpcs TestManagerPro Software CD lpcs Waterproof Package lpcs User s Manual lpcs Quality Certificate Card lpcs Maintenance Cal iacchotatoreshuatipnaborsteteeeianess lpcs PACKS IS atcaaneusorasyorsscbaccsaseeananuanencasccousiowe l pcs Option Cable Datacom Adapter Cables cccccc cece cece eeeee ees Apcs Datacom Interface Loop back Connector Ipes 703 CO Test Cable iectay ci stuacutvale o2aacasuet condensed lpcs Ordering Information PATI IU cnciictieimaacnant E1 Datacom Transmission Analyzer option excluded Op On EOE E Jitter Testing optional COO Leier toes saN Datacom Testing optional Option 3 iicsveriwresesaced G 703 64kb s CO Testing optional Option 4 iacceicadadsseneews Mux amp Demux Testing optional Option 5 ccc cece eee Drop
5. med and unframed testing V Hi Z and through mode testing V CODE FAS CRC4 E BIT BER testing V Frame data and timeslot activity monitoring V Monitoring of octet code in any selected timeslot V Built in 64kb s tone channel monitoring capability V ABCD code monitoring in CAS signaling V TS16 monitoring in CCS signaling e Double E1 channel testing V Double E1 channels Rx Hi Z and through mode testing V Double E1 channels Code FAS CRC 4 E BIT BER testing V Double E1 channels FAS NFAS CAS Multiframe CCS timeslot 16 and timeslot activity monitoring V Double E1 channels timeslot data monitoring V Double E1 channels built in 64kb s tone channel monitoring capability V Double E1 channels CAS and CCS signaling monitoring e Round trip delay measurement e APS delay measurement e Pulse Mask Measurement V Input El pulse shape display V Pulse width measurement V Pulse width and amplitude ratio measurement V Up edge and down edge time measurement V Overshoot and undershoot ratio measurement V Pulse amplitude and level measurement e PCM simulator V Extensive error insertion and alarm generation V Frame data control and monitoring V Idle word insertion in one or more timeslots with programmable pattern V VF tone generation and measurement in one or more timeslots V Listen to any voice channel in the receiver via earphone V Talk to any voice channel in the transmitter via microphone V Can perform the tests of signal le
6. vel and frequency of the VF channel simultaneously V CAS and CCS signaling generation and monitoring e Frequency and Offset measurements e Level measurement e Transmit clock deviation up to 999ppm e Clock source Internal Interface and External 2M clock signal e Testing pattern PRBS Fixed Code 16 BIT User programmable word e Error insertion Single and Fixed Rate e Real time transmit circuit status indication open short e Manual or auto timer measurements e Performance analysis according to G 821 G 826 and M 2100 Network Testing e IP PING e Trace Route e IP Config Other Functions e Auto configuration V El frame format BERT pattern the timeslots carried BERT pattern automatic detection and setting for El testing V BERT pattern and Tx data rate automatic detection and setting for Datacom testing V BERT pattern and octet timing automatic detection and setting for G 703 64kb s CO testing e Real time clock e BERT pattern PRBS Fixed Code 16 BIT User programmable word and QBF e Error insertion Single and Fixed Rate e Reset the results to zero and auto configure e Manual or auto timer measurements e Self check keyboard and LED testing e Performance analysis according to ITU T G 821 G 826 and M 2100 e Histogram analysis of error and alarm events e Upgradeable software via USB interface Option 1 Jitter Testing e Peak to peak jitter measurement e Jitter measurement comply with O 172 filter
7. y Deviation 64kb s 100ppm 999ppm Line Interface Line Interfaces 1209 Balanced 75O Unbalanced 120Q Balanced Line Code High Input Impedance gt 2KQ AMI Line Code HDB3 AMI 2 Datacom Testing Frame Type i Line Interfaces Unframed PCM30 PCM30CRC PCM31 EC V 24 V 35 V 36 X 21 RS 449 RS 485 EIA 530 EIA 530A Receiving Sensitivity Data Rate gt 43dB ASYNC 50 75 150 300 600bit s 1 2 2 4 eee SYNC 12 24 48 7 2 9 6 19 2 38 Internal Interface and External 2MHz clock or as pea E oa HDB3 signal Nx64kb s N 1 32 Pulse Mask Measurement Test Patterns Comply with G 703 PRBS 223 1 220 1 215 1 211 1 29 1 26 1 Fixed Code 1111 0000 1010 Jitter Measurement 16 BIT User Programmable Word Comply with G 823 O 172 PRBS Polarity Normal or Inverted QBF QBF1 QBF2 QBF3 QBF4 Frequency Measurement Accuracy 1Hz LED Alarm Indications SIG LOSS AIARM PAT LOS ERROR Offset Measurement HISTORY Accuracy lppm Error Insertion Type BIT FAS CODE CRC4 E BIT Single OFF Fixed Rate 10 2 10 3 10 4 10 s Range 999ppm 999ppm VF Insertion 10 6 10 7 Frequency 200Hz 3400Hz Step 10Hz Level 60dBm 3dBm Performance Analysis Microphone mode ITU T G 821 G 826 and M 2100 VF Measurement Serial Port Frequency 200Hz 3400Hz USB Connector Accuracy 1Hz Display Level range 60 00dBm 3 14dBm 4 3 inch large size display with backlit color touch Screen Rechargeable