        CapSmart-VFD Caprari - Variable Frequency Drive
         Contents
1.   Use the    and     buttons to alter the parameter setting                       Start H    Auto reset test n   this parameter sets the number of attempts that the  CapSmart VFD will make to resolve a stop condition due to dry running   Once this limit has been exceeded  the system shuts down and the user   s  intervention is required  If this value is set to zero  the auto reset function  is switched off  The maximum number of attempts allowed is 10  Use the    and     buttons to alter the parameter setting      Maximum number of starts in an hour  From this page you can set the  maximum number of starts of the motor pump in one hour before the  intervention of the Serious Leakage alarm  Only short starts are counted  in  other words those which are not followed by the suction of minimum 2 5  litres min of water  If the Serious Leakage alarm is activated too often or  without reason  then it is advisable to increase the parameter on this page    using the         button  If on the other hand you wish to completely deactivate the leakage control  then  button until the word    OFF    appears on the bottom line of this page     13    Language  The language used for the menus and the alarm messages can    ardilzAE be selected by the user  Use the   and     buttons to alter the parameter    EH setting      INSTALLER PARAMETERS     These parameters can be found on hidden pages and usually they should only be changed in the  installation phase  To access these pages switch the de
2.  PID parameter     Minimum frequency  Use this parameter to set the minimum frequency of    pr  i Fla Freg the motor pump power supply  i e  the number of rotations   The value is  mn expressed as percentage of the maximum frequency value  The parameter  Md can be set at the following values  50  60 or 70   For surface pumps a 50     minimum frequency is recommended as set by the manufacturer  for   pumps submersed up to a depth of 8 10 metres a 60  value is  recommended  for pumps submersed over 10 metres the parameter should be set at 70   In any case  it is  useful to increase this parameter when the start up of the motor pump is too slow and there is a significant  loss of pressure in the system during this phase  Use the         and     buttons to change the minimum  frequency values     Imax  this parameter is used to set the maximum current that must be  I Max absorbed by the motor pump in ordinary conditions  so that the motor will  aac stop in case of excessive absorption  The motor shall stop also if the  J  H current measured during operation is lower than 0 5 A following the  interruption of the connection between the motor and the CapSmart VFD   The intervention time of the protection in case of excessive absorption is inversely proportional to the  overload  therefore a slight overload shall trigger longer intervention times while a great overload will  lead to a rapid interruption  The parameter can be set at a value between 0 5 a 9 7 A  When the device is  swi
3.  device from the electric power supply and  solving the causes of the fault  Attempting to start the inverter when there is an output short circuit may  seriously damage the device and be dangerous for the user           Dep    1 oad    Overload  This alarm appears when the absorption of the motor pump is  greater than the maximum current value set  Imax   this may be caused by  extremely difficult working conditions for the motor pump  problems  related to the motor winding   if the pump is restarted continuously at    15    short intervals or following problems with the wiring of the motor to the CapSmart VFD  If this alarm is  often displayed the system should be checked by the installer             POSSIBLE MALFUNCTIONS     v When one of the valves in the system is opened  the pump does not start  or there is a few seconds  delay before it starts    The Pmin is set too low or a check valve has been fitted downstream of the device  Try increasing the  start pressure Pmin and remove all check valves fitted downstream of the CapSmart VFD     v When the valves are closed  the pump stops but restarts a few seconds later and there is no  leakage from the system    The difference between the Pmin and the Pmax is too low and the drop in pressure that occurs when the  pump stops is sufficient to make it restart  Increase the Pmax value or decrease the Pmin     v The pump keeps switching on and off   There is leakage in the system  Check the various hydraulic connections  Check the
4.  display for pressure  drops when the valve is closed  Check the CapSmart VFD s check valve for dirt which could be  preventing it from closing properly and  if necessary  clean it with compressed air     v The device often signals  dry running     The pump intake pipe drains when the system is not used for some time  thereby preventing it priming  the next time it is started  If there is a foot valve fitted  check its seal     v The device frequently signals an inverter error    The supply voltage may not comply with the equipment specifications  the control must be carried out by  qualified personnel    The inverter no longer exchanges heat with the water that runs through the device or the temperature of  the fluid pumped is too high  check for foreign bodies that block the flow of water and if necessary have  the device checked by the manufacturer     v When the water flow is extremely low  the pump does not operate normally     The flow values are too low and as the device is unable to detect them  it shuts down the motor pump  Fit  a small surge tank  1 2 litres  in the system to give it more flexibility and reduce the number of restarts     v The pump does not stop   There is substantial leakage in the system or the check valve on the device is jammed by dirt  try moving  the check valve with your fingers and checking that the spring can maintain the seal    The sensor which detects the valve position is broken  Have the device checked by the manufacturer     v The pum
5.  rated frequency of 50Hz and a capacity of up to 2200 Watt     The equipment is fitted with an output short circuit protection     The wires have a 1 5 mm  section and lengths of up to 30 m  for lengths from 30 m to 90 m it is  recommended that 2 5 mm  section wire be used     The type of wire must be selected according to the conditions of use  domestic  dry or wet  indoor or  outdoor installation         v LINE CONNECTION       The device has a single phase 240 Volt 50Hz power line   The electrical system to which the equipment is connected  must comply with the safety regulations in force and must  therefore be equipped with       an automatic magnetothermal switch with high breaking  capacity and with a trigger current proportional to the  capacity of the pump installed  see chart below      earthing with total resistance in conformity with local  standards and in any case never over 100Q           240V 50Hz  If the device is used in swimming pools  fountains or garden ponds  an automatic type    A    residual  current operated circuit breaker  with IAn 30mA  must always be fitted     The system comprising the CapSmart VFD and a motor pump is considered a    fixed system     it is  therefore advisable to make arrangements to prevent the device being disconnected from the power line it  was originally connected to and mistakenly reconnected to another source of power not equipped with the  electrical protection required    If the device is not fitted with a power lead and 
6. 254x147x143 mm   Type of action    a 1  according to EN 60730 1        FEATURES    N Constant pressure due to motor pump speed regulation   y Energy savings due to less pump absorption   Y Gradual pump start and stop reduces hammering   y Protection against dry running in the event of water shortage during intake   Y Automatic reset in the event of dry running  with autonomous error condition recovery  y Efficient leakage monitoring to protect pump in the event of repeated restarts  y Digital pressure display   y Operation error status signalling via LEDs and on screen alerts   y Auxiliary contact for remote control  pair connection or double set point     Rotation direction inversion via software  does not require wiring alterations   y Extractable terminals to facilitate wiring   y Possibility of interfacing two devices as part of the pressurisation units      DEVICE PROTECTION FEATURES    y Dry running   y Undervoltage on power line  activation at approx  200 Volt   y Overvoltage on power line  activation at approx  260 Volt   y Output terminal short circuit     Motor output amperometric control   y Internal overheating in inverter   y Significant leakage with continuous motor pump restarts      INSTALLATION       HYDRAULIC CONNECTION   Note  If supplied as a CAPRARI Pump System  the following has already been taken care of for you     The CapSmart VFD must be installed on the pump delivery side  either upright or horizontally and  respecting the flow direction shown by th
7. caprari     pumping power  CapSmart VFD    Caprar     Variable Frequency Drive       Owner   s manual       240V  10 Amps     N WARNING     READ THIS HANDBOOK CAREFULLY BEFORE INSTALLING OR STARTING  THE DEVICE     The manufacturer guarantees this product for a period of 24 months as of the date of sale  if  returned  the device must be accompanied by this handbook  with the installation date and  programming parameter values entered on the last page    The guarantee is forfeited in the event of the following  the device is tampered with  disassembled or  damaged due to mishandling and or incorrect installation  the device is put to any other use than the  one it was intended for  the device is installed in unsuitable environmental conditions or connected  to a non standard electrical system    The manufacturer cannot be held responsible for any kind of damage to people and or things ensuing  from failure to install the necessary electrical safety devices upstream of the device  or as a result of  unprofessional installation    The installation and servicing of this device must be performed by specially trained personnel with  the ability to understand the entire contents of this owner   s manual    For all operations required to be carried out with the cover removed  the device must be  disconnected from the power supply    Even though there should not be any reason to remove the card  if you do so  remember that some of  its parts remain live for a few minutes after the uni
8. chine aufgrund ihres Konzepts  der Bauart  und der von uns auf den Markt eingef  hrten Ausf  hrung den grunds  tzlichen Anforderungen  bez  glich der Sicherheit und der Gesundheit der EG Richtlinien entspricht  Falls die Maschine ohne  unsere Zustimmung ge  ndert wird  verliert diese Erkl  rung jegliche G  ltigkeit     MODEL  CapSmart VFD    TYPE  SR23251 XX XXX    RICHTLINIEN  MARKIERUNGS JAHR     2006 95 EC EN 60730 1 2002   LVD   2004 108 EC EN 61000 6 4 2007   EMC EN 61000 6 2 2006  Tribano  29 July 2008    Mr  Demetrio Bertazzo    For    CAPRARI Pumps Australia Pty Ltd  3 Jeanes street   Beverley SA 5009   Ph   61 8 82444442   Fax   61 8 82444462   Web  www caprari com       21    Caprari Pumps Australia  3 Jeanes St Beverley South Australia  Tel   61 8 8244 4442  Fax   61 8 8244 4462    www caprari com    22    
9. e arrow on the cover  The pump outlet water flows through the  device before being distributed to the various appliances connected    The water that enters the CapSmart VFD unit must not contain any impurities and or other substances  that could jam up the check valve fitted inside it  To reduce this risk as much as possible  it is advisable to  fit special filters on the intake side of the pump    Install a small expansion tank  1 2 litres  after the CapSmart VFD  to limit restarts caused by any small  leakages which are common in most systems  The pre charge value of the tank must be suitable for the  pressure values set  This will also help to keep the operation constant in applications where water  requirements are greater  e g  for dishwashers  toilet flushing systems  etc      On no account must a check valve be fitted between the CapSmart VFD and the motor pump or between  the device itself and the user appliances  as it could cause device malfunctions    A check valve can be fitted on the motor pump intake pipe  though  to prevent it draining when the pump  stops    It is recommended that you do not install the equipment in shafts or watertight casing where heavy  condensation can form           A CAUTION  when the pump stops  the conduits are still pressured so a cock must be opened to bleed  the system before any work is carried out     M ELECTRICAL CONNECTION     Note  If supplied as part of a CAPRARI Pump System  the following has  already been taken care of for y
10. e is used  If the device is set to work  independently no connection is required  On the other  hand  if the CapSmart VFD is connected to another  unit to create a pressurisation group  follow the wiring  diagram shown here  for further information on the  operation as part of twin pump pressurisation units see  the    PRESSURISATION UNITS    section in the  appendix     E WN    DOM ad       SETTING OF    AUXILIARY CONTACT    PARAMETER      2      Remote on off control function    When the    AUXILIARY CONTACT    parameter is  set on    2    the CapSmart VFD is set to be switched on    and off by remote control according to the system EXTERNAL  requirements  This function is useful when there is the   CONTACT  need to programme the start of the motor pump at the  same time as other devices connected to one same  control unit  for example in irrigation systems where  the pump is switched on only when the irrigation  control unit activates one or more of the system   s  solenoid valves  Connect the device according to the  wiring diagram shown here  bearing in mind that when  the external contact is open the CapSmart VFD shall i  not start the pump even if the system reaches the Pmin value  while when the external contact is closed  the device shall operate according to the values set         SETTING OF    AUXILIARY CONTACT    PARAMETER      3      Second set point   Pmax2  function    When the    AUXILIARY CONTACT    parameter is  set on    3    the CapSmart VFD is set to adju
11. ed           OPERATION  at the time of power on the first device that gets the control over the other  becomes the MASTER while the other functions as the SLAVE  When user services are opened  the MASTER device starts the pump and when the maximum rotation speed is reached and the  system pressure is lower than the preset Pmin value  it transfers control to the second inverter   which becomes the new MASTER  while the first inverter becomes the SLAVE and its rotation  speed remains fixed  With the progressive closing of the user services the second device stops  the pump and control is again transferred to the first inverter  which will stop the electric pump  when the water demand is reduced to zero after complete closing of each user  After the  electric pump has been stopped MASTER status is again transferred to the other device to  ensure constant changeover of the pump that is started first  In the event of a fault or error on  one of the two inverters  the healthy device will automatically assume MASTER status and start  operating in stand alone mode    To activate the changeover function it is not necessary to set any parameters in the menu  because CapSmart VFD automatically detects the presence of a secondary device once the  electrical connection has been made    The Pmin and Pmax values set must be the same for both devices     19       CE DECLARATION OF CONFORMITY    IT   Con la presente si dichiara che la macchina qui di seguito indicata  in base alla sua concezi
12. ep the pressure as near as  possible to the value set for the Pmax  The minimum differential settable    between Pmax and Pmin is 0 3 bar  although it is advisable to keep it at least 0 5 bar  Use the   and      buttons to alter the parameter setting     Delas 10    Stop delay  Use this parameter to define after how many seconds the motor  pump should stop once all the functions have been closed  If when the  flows are low the pump continuously switches on and off  increase the  switching off delay so that the operation is smoother  Increasing the  parameter can also be useful to stop the frequent triggering of the dry run    protection device especially in submersed pumps or pumps that have self priming problems  The default  value set by the manufacturer is 10 seconds  Use the         and         to change the stop delay value                    Auto reset interval  if the pump experiences a temporary shortage of  intake water while it is operating  the CapSmart  VFD cuts off the power to  the motor to prevent it being damaged  From this screen page  a device  automatic restart time can be set  in minutes  at the end of which a test will  be run to see if the intake water supply has returned  If the test is  successful  the CapSmart VFD automatically quits the error status and the    system becomes operative once again  if it fails  another attempt will be made after the same amount of  time has lapsed  The maximum interval allowed is 300 minutes  recommended value  60 min 
13. he cause of the alarm has  been established  press the    reset    button in the centre  If this condition  occurs repeatedly  impairing normal pump operation  this feature can be    disabled  Before disabling  though  ensure it will not cause damage to the pump or system  see section  titled    DESCRIPTION OF THE PARAMETERS AND THE SCREEN PAGES         Inwerter  error    Inverter error  this alarm appears when the inverter is locked following a  power surge or drop outside the limits or overheating with ensuing motor  pump shutdown  Although the system is restored automatically approx  3  minutes after the error condition has cleared  the message remains on the  screen to warn the user that there might be a failure in the hydraulic and or    electric system  Every time this alarm appears  it is advisable to have the system checked by skilled  personnel to prevent electrical damage  To clear the message from the display  simply press the    reset       button in the centre     Short  Circuit    Short Circuit  This message will appear on the screen when there is a  short circuit at the inverter output  the short circuit may be caused by the  incorrect connection of the electric motor  faulty electrical isolation of the  cables that connect the motor pump to the devices or failure of the electric  motor of the pump     When this error appears  the electrical system must be controlled by qualified personnel as soon as  possible  The error can only be cleared by disconnecting the
14. in twin    booster sets  NOTE  for CAPRARI    Multi Cap        Cvx  System   MORSETTIERA Ot z  COLLEGAMENTO        eK E A A at   INSTALLATION  install each CapSmart VFD  u Lo unit on the pressure line of the corresponding    electric pump  Connect the outlet union of  each inverter to the delivery manifold without  interposing a check valve  Connect the  suction of the electric pumps to the common  intake manifold  interposing a check valve for  each pump to prevent it from emptying when  stopped  CapSmart VFD is compatible with  both vertical and horizontal installation     CONNECTION  the two CapSmart VFD units  are connected by an unshielded 4x0 5 mm2  cable as shown in the diagram beside  The  maximum cable length is 100 cm including stripped ends  Customers can order a preassembled  connection cable with terminals and cable  numbering   Ref  SR CBL4X05 100  If no  cable is connected the device will function in  stand alone mode           MASTER STATUS   when the device  works as a MASTER it is sensitive to pressure changes in the plant and  thus capable of starting and stopping the pump unit and modulating    pump rpm in accordance with water demands from the plant     1 4 Bar  ARS    a       1 6 Bar    DE HEES    SLAVE STATUS  when the device works as a SLAVE two capital S  characters appear on the display bottom line  in this condition if the  pump is running the speed remains constant  while if the pump is  stopped its starting is inhibited even when the taps are open
15. nd resets the unit in the    event of alarms and or errors                button  this increases the value of the parameter currently shown on the display  it allows the  pump to run at top speed under forced operation                button  this decreases the value of the parameter currently shown on the display  it displays  the instantaneous current absorbed by the motor     11    v MENU STRUCTURE                                                                                                             el jo    Start H       EEN IE q er         2 eset  amp   P  d Landiade      gt  EM  o    v DESCRIPTION OF THE PARAMETERS AND SCREEN PAGES    USER PARAMETERS     These parameters are accessible when the device is on           SER                            Main screen page  when the CapSmart VFD is in the standard operation  mode  the first line on the display shows the instant pressure reading  the  second line contains a bar chart showing the motor speed as a percentage   In this mode  the user can scroll through the various menus using the  cursor buttons  or switch to stand by by pressing the    on off    button in the  centre  When the CapSmart VFD is in stand by  the pump will not start up  even if the pressure drops below the    Pmin    value set  To quit stand by   press the button in the centre again    If the         button is held down  the pump is brought up to the maximum  operating speed  overriding the dry running protection  use this function to    fill the p
16. ng    Check that the motor pump is rotating in the right direction  if it is not  the motor phases can be inverted  using the software  see    programming    paragraph  without needing to open the cover again    To facilitate pump filling  the    4    button on the main screen can be pressed to force the pump up to top  speed without the dry running protection feature cutting in     After setting all the device parameters  write the data entered in the form found at the end of this  handbook for future reference and for guarantee purposes                 al PROGRAMMING     v DESCRIPTION OF THE INTERFACE       Note  If the device has been supplied as a part of aCAPRARI System  N    and your operations parameter have been provided at the time of   ordering  these values will have be pre set for you  As confirmation this    values will be hand written in the back of this manual  4 E S j p i O   1  Digital display  showing pressure  errors and configuration menus  a N    a    2  Motor pump start  stop and programming buttons  3 N ee 6 Wa   3  Green warning light to signal line is live  LINE  Ng ef So cep  4  Red warning light to signal error conditions  FAILURE  i    5  Yellow warning light to signal pump operation  PUMP ON  a    toa pi hari mus  v DESCRIPTION OF THE BUTTONS 2       Left hand arrow  this scrolls back through the menu pages     Right hand arrow  this scrolls forwards through the menu pages  e On Off Reset  this switches the device from stand by to operation mode a
17. one   al tipo di costruzione e nella versione da noi introdotta sul mercato     conforme ai requisiti  fondamentali di sicurezza e di sanita delle direttive CE  In caso di modifiche apportate alla macchina  senza il nostro consenso  la presente dichiarazione perde ogni validita    RUS   Hacros  mmm 3aABIIACTCA  UTO oOopyoBaHHe  yKa3aHHO    B PYKOBOJICTBe  a MMCHHO  Cro  ODHTHHAJIBHBI Iu3ahH  THII KOHCTDYKTIHH H MONENB  BbIHYIIEHHAA WIA NDOMAKH    COOTBETCTBYET OCHOBHEIM  HOpMaM TEXHHOKM 6   30IaCHOCTH H He TPEACTABIIAET Yrpo3y AIOPOBEIO COTJIACHO THpeKTHB CE B cJIyuae  KAKHX JIHOO H3MEHEHHI OOODYZIOBAHHS  KOTOPbI8 HECAHKIMOHMPOBAHHBI C H3TOTOBHTEJIEM  AHHAA  ASKIapauma   yAeT MpH3HaHa HETEHCTBHTETBHOI    FR   Nous d  clarons par la pr  sente que la machine indiqu  e ci dessous  telle qu elle a   t   concue   construite et commercialis  e par notre entreprise  est conforme aux exigences fondamentales de  s  curit   et de sant   des directives CE  En cas de modifications apport  es    la machine sans notre  accord  la pr  sente d  claration n a plus aucune validit      ES   Con la presente se declara que la m  quina mencionada a continuaci  n  seg  n su dise  o  tipo  de fabricaci  n y en la versi  n comercializada  responde a los requerimientos fundamentales de  seguridad y de sanidad de las directivas CE  En caso de modificaciones hechas a la m  quina sin  nuestra autorizaci  n  esta declaraci  n pierde su validez    DE   Hiermit erkl  ren wir  dass die wie folgt genannte Mas
18. ou     Fit the electric wires into the relative wire clamps  making sure the correct  assembly order is maintained for all the components  Secure the threaded    nuts tightly enough to prevent the wires being pulled or turned from the iy Ep  outside  The wire clamp for the auxiliary contact is a blind fastener  if you i  wish to insert a remote control wire  it is best to remove the said nut from  the unit  then break open the plastic nut with a screwdriver           If the device is used in one of the following situations       temperature of the fluid used higher than 30  C    ambient temperature higher than 35  C    cables with a thermal resistance of at least 100  C must be used for the power supply and motor cable     v MOTOR PUMP CONNECTION    CapSmart VFD can be fitted on three phase pumps with 240Vac power supply  with a triangular set up  then  This means that the terminals inside the pump must be checked before wiring up the device to  ensure they are connected as shown in the figure below     MOTOR  3X230V           Before making the electrical connection  the cables must be correctly prepared with the relative terminals  to be crimped  Connect the three power wires of the pomp motor to the 3 pole green terminal marked     MOTOR     then proceed with connection of the earth wire to one of the ends of the double earthing  terminal  The terminals must be crimped by specialist personnel  using special pliers for the purpose   This device can run with pumps with a max 
19. p is running at top speed but performance levels are low    The pump might be running backwards  Try inverting the rotation direction   The pump is damaged or there is foreign matter clogging the waterway     16    v When more water is required of the system  the pressure drops    This is a normal condition which is due to the fact that the device is unable to force the pump above its  capacity curve  As a result  once a certain capacity is reached  the pressure is no longer offset as the pump  is already running at the highest number of revolutions allowed  In these cases  a pump with higher  performance levels should be installed     v The    Inverter error    message often appears on the display a few seconds after the motor pump is  started    The error may be caused by a non compliant power voltage  With the pump running  use a suitable gauge  to measure the voltage at the power terminals and determine whether the problem concerns  underpowering or overpowering  If it is the former  use a power lead with a larger section to reduce  voltage drops  but if it is the latter  contact the manufacturer     17      MAINTENANCE     The CapSmart VFD is designed to keep maintenance requirements at a minimum  To guarantee the  device a long working life and perfect functionality  always follow the instructions below   Place your CapSmart inside a pump cover or shelter  do not expose it to the wheather and direct elements       ensure the device does not have to withstand temperature
20. ploying inverter based technology  which controls motor  pump  speed  stopping and starting functions    Thanks to the particular type of technology used  it can modulate the frequency  Hz  of the motor   s input  current to alter the speed  rpm  according to the water delivery rate required from the system    This way  the value of the pressure reaching the user appliances is maintained constant all the time and  the motor s absorption is always proportional to the actual system requirements  resulting in notable  energy savings over time           5 SPECIFICATIONS    Power mains supplY       sesse sesse ese ee single phase  240Vac  10    5    50Hz  Motor power supply               cce eee e eee e ees three phase 230V    Maximum power absorption                    2200W   3Hp   Maximum motor phase current                 9 7Arms   Max  line absorption                2 ssec nen 16A   240V    Max  allowable pressure                           800 KPa  8 bar    Max  liquid temperature            22222 2  50  C   Max  theoretical flow rate                       150 Vmin   9m  h     9000 Vh  Set point adjustment range                      1 5 7 bar   150 700 Kpa    Start pressure adjustment range                 1  6 7 bar   100 670 Kpa    Hydraulic connection                 sees seen ee BSP   32mm     Frequency modulation range                     25 50 Hz  30 60Hz optional   Degree of protection u  DEE N ue IP X5   Weis ht Gis oc O ee a  1 6 Kg   DIMENSIONS    asia ed SEE seen 
21. plug  to disconnect it from the mains install an omnipolar  cut off device with a gap of at least 3 mm between the contacts     Before making the electrical connection  the cables must be correctly prepared with the relative terminals  to be crimped  Connect the two power wires  of the device to the 2 pole green terminal  marked  LINE   then proceed with  connection of the earth wire to one of the    CAPACITY OF PUMP   MAGNETOTHERMAL  INSTALLED PROTECTION   KW   A     0 37  0 5 HP     ends of the double earthing terminal  The  0751 PY   6  gt  AN terminals must be crimped by specialist  personnel  using special pliers for the  purpose   The recommended wire section is 1 5mm2  which is compatible with motor pumps up to 1 1 kW  For  powers over 1 1 kW and up to 2 2 kW a 2 5mm  wire section is recommended   If the power lead is longer than 5 10 metres  a lead with a 2 5mm2 section should be used to reduce drops  in the power supplied by the lead and to reduce the chance of the under voltage protection being  triggered        The type of wire must be selected according to the conditions of use  domestic  dry or wet  indoor or  outdoor installation      All installation restrictions stated by the manufacturer of the motor pump to which the CapSmart VFD is  connected must also be observed      N WARNING      all wiring up must be carried out by specially trained personnel     an incorrect motor pump connection could result in damage to the device or the pump motor     the manufactu
22. rer cannot be held responsible for any kind of damage to people and or things  ensuing from failure to comply with the contents of this paragraph      failure to comply with what is stated in this paragraph may cause serious damage to things and or  serious injuries to people  and the manufacturer declines all responsibility      if the power supply cable or the cable between the CapSmart VFD and electropump is damaged   only the manufacturer of the device  its appointee or equally qualified personnel can replace it  this  is to prevent risks to things and people     v AUXILIARY CONTACT CONNECTION    WARNING  the auxiliary contact connector is not extractable                     CapSmart VFD is fitted with a special connector for an  auxiliary contact so that additional functions can be  exploited by interfacing the device with external  equipment  The function of the auxiliary contact depends  on the setting of the    Auxiliary Contact    parameter  described in the paragraph on programming  The three  operational modes  relevant functions and connection  methods are described below     AUXILIARY CONTACT  CONNECTOR    SETTING OF    AUXILIARY CONTACT    PARAMETER      1      Exchange function in the  pressurisation units     When the    AUXILIARY CONTACT    parameter is  set on    1    the CapSmart VFD is set to work  independently  single system  or to dialogue with  another partner device as part of a twin pump  pressurisation unit  depending on whether the  connection cabl
23. s of below 3   C  if this is not possible  make  sure all the water inside it is drained out to prevent it from freezing up and damaging the device   s plastic  body      if the pump is equipped with intake filters  carry out regular checks to ensure they are clean      make sure the cover is always properly closed to prevent water leaking in from outside      switch off the power supply and drain the water from the system when it is going to be left unused for  some time      do not force the pump to run without intake water  as this could damage both the pump and the  CapSmart VFD      before using the device with any other liquids than water  contact the manufacturer      do not carry out any operations when the device is open     wait 3 minutes before removing the cover from the device so the condensers can discharge     A WARNING  this device does not contain any parts that can be repaired or replaced by the end  user  You are therefore advised not to remove the electronic card s protective cover as this would  lead to forfeiture of the guarantee     Installation date voed Ed esse      Fitter       Customer      Pump make model  gt     CapSmart VFD serialo    o OE  Pmax  Pmax2  Stop delay  Auto reset time    Auto reset test  Start hour max NO YES  n   max start          gt                       Rotation direction                                  Minimum frequency  Imax   Auxiliary contact  Notes                                           18    Installation and connection 
24. st the  rotations of the motor pump in accordance to the  Pmax2 pressure value  This function is useful when  the device must temporarily work at a different  pressure to the one set in the Pmax parameter  for  example if distributors requiring different pressures  are used  Connect the device according to the wiring  diagram shown here bearing in mind that when the     external contact is open the CapSmart VFD shall i   adjust the pump rotations according to the Pmax   pressure value   while when the external contact is closed the device shall adjust the pump speed  according to the Pmax2 value       EXTERNAL  CONTACT    A ATTENTION  incorrect wiring of the auxiliary contact may cause the low voltage circuit to  short circuit with consequent blowing of the fuse  Carry out the connection with particular care     10    0 START UP      NWARNING  do not allow the pump to run for long without water the first time it is switched on  otherwise the inverter will overheat  Prime the pump before switching on the system     Once all the electrical connections have been made and checked to ensure they are correct  close the  unit   s cover and switch on the power    The CapSmart VFD is now in stand by  in this mode  pump stationary  all the various parameters can be  set  see    programming    paragraph  before the system is started up    To start up the pump  simply press the    on off    button in the centre  The CapSmart VFD will quit the  stand by mode and the motor will start turni
25. t has been disconnected from the mains    The manufacturer cannot be held responsible for any kind of damage to people and or things ensuing  from the failure of any internal safety devices to intervene  with the exception of compensation for  the device itself if still under guarantee     This equipment complies with the ROHS 2002 95 EC directive   The symbol of the crossed out bin means that to safeguard the environment the equipment  cannot be disposed of with other household waste at the end of its lifecycle  The equipment  and packaging must be disposed of according to the local regulations      gt  CONTENTS    OVERALL SIZE   DIMENSIONS   IDENTIFICATION            sccccccsssesccscccccccececseees 22    DESCRIPTION  See Ee dee Ge a GN GE WEG be A NE Ge N ee 23  SPECIFICATIONS uses 23  BEA TURES inc osse ee ii 23  DEVICE PROTECTION FEATURES    ana a a ne 24  INSTALLATION  HYDRAULIC CONNECTION 23 0 ee 24  ELECTRICAL CONNECTION sa a a wes bi Gee ER 25  SEAR TUB  ae ses ana ia nu 29  PROGRAMMING  DESCRIPTION OF THE INTERFACE   susse ese ann 29  DESCRIPTION OF BUTTON FUNCTIONS    sees ese sesse sesse sesse se se see se se se ee se see ee 29  MENU STRUCTURES ss ese 22a ie 30  DESCRIPTION OF THE PARAMETERS AND SCREEN PAGES        sesse sesse ese sees ee 30  OP  dd EE OE OE EIE N ES 33    POSSIBLE MALFUNCTIONS os lesse sede eie ge ada  MAINTENANCE sur 35     lt  gt  OVERALL SIZE   DIMENSIONS  IDENTIFICATION    M20x 1 75       DESCRIPTION    CapSmart VFD is an electronic device  em
26. tched on if the Imax parameter is set at 0 5 A  manufacturer   s default setting   the page from which to  set the maximum current value will be displayed  no action can be carried out until the maximum  absorption value has been set     14    Aur  Cor   1  lt   gt     setting     Auxiliary contact  use this parameter to select the function to be  associated with the auxiliary contact  the values that can be set are the  following       1  lt   gt     to use the auxiliary contact to connect two CapSmart VFD  devices as part of a twin pressurisation unit  manufacturer   s default       2  lt    to use the auxiliary contact to remote control the start stop of the motor pump        3 X2    to use the auxiliary contact to control a second pressure set point  Pmax2    Further information on the wiring and on the three different operational modes is contained in the     AUXILIARY CONTACT CONNECTION     section     v ALARMS       Crt  running    St  1 OLS   leaks    Dry running  this message appears when the system is stopped  following a pump intake water shortage  If the auto reset function has  been enabled  the CapSmart VFD will automatically make a series of  attempts to test whether the water supply has returned  To clear the error  status  press the    reset    button in the centre     Serious leakage  this message appears when the pump has been stopped  following a closely spaced series of restarts caused by a possible leak in  the system  To restore the system status once t
27. ump the first time it is switched on   Press the         button to display the absorption of the motor                          Pmax  this parameter can be used to set the device set point  This is the  constant pressure value the user wishes to set for the system  max   pressure   When it is operating  the CapSmart VFD regulates the motor  pump speed to suit it to the actual output required by the user appliances   thereby keeping the system pressure constant  If the Pmax is set to higher    than the max  pump head  the motor will always stop when the cocks are closed as the CapSmart VFD  switches off the pump when the flow rate of the water running through it drops below the minimum  settings  approx  2 litres minute   regardless of the pressure reached in the system  Use the   and      buttons to alter the parameter setting     12                         Pmax2  this page is only displayed if the    AUXILIARY CONTACT      parameter is set on    3     second set point function   this parameter is used  to set the secondary set point of the device  When the auxiliary contact is  externally closed the Pmax2 pressure value becomes the new set point  according to which the CapSmart VFD adjusts the speed of the motor          Pmin  this value represents the pump restart pressure  When any user  appliance is switched on  the pump does not start up until the system  pressure has dropped below the Pmin value  Once the motor has started  running  its rotation speed is regulated to ke
28. vice to Stand by and keep the         and         buttons  pressed down together for 5 seconds  Once you have entered the hidden menu  use the     lt  lt     and     gt  gt      buttons to scroll the pages and the         and         buttons to change the parameters  To return to the main  page press the button in the centre     Rotation direction  The direction of rotation of the motor pump can be    Rotation inverted from this page without having to change the wiring of the electric  N motor  To change the direction of rotation of the motor use the         and        emf     buttons  the direction shown by the arrow is merely indicative and does    not represent the actual direction of rotation which must in any case be  checked by the installer     PID Control  This parameter is used to set the speed of reaction of the               F I O system to changes in pressure  accelerations and decelerations   Low PID  Er  values represent a slow but more accurate reaction  more gradual start and  Me oe    stop  while the higher values of this parameter can be used for a higher  reaction speed  When the system is unstable  pressure oscillations with  conseguent changes in the speed of the motor  it is advisable to set the lower PID values  On the other  hand  when the system s reaction to pressure variations is too slow we recommend increasing the PID  value  max  50   The default value set by the manufacturer is 25  Use the         and         buttons to change  the values of the
    