The RLITE products MODEL X2 User Manual

image

Contents

1. 22 Analog inputs calibration 2A models 23 Linear conversion and sensor calibration 23 To carry out nonlinear transformation eee entente enne 24 Ch nping Removing Tag noU E E et YER e eee 25 WORKING WITH CONDITIONS cccccccssscsssceesseceeeeessecsececssecsseeeeseeceseeeessecsseeeeaaeceseesesseeseeeesaeenses 26 Adding a New Condition REN Rae 26 Attaching Valles 29 Changing Removing a Condition 30 ASSOCIATING USERS AS CONDITION S 000000 0000000000000000000 31 Selecting Condition s Recipients esses enne nre 3l RLITE WEB MODELS ADVANCED 6 5 2 242 eene 32 Selecting Channels and Logging Rate sse ene 32 Defining Dispatch Tasks i RUE Ea DAL Roh 33 DOWNLOADING UPLOADING eese een ense suse ta sens 34 CONNECTING WITH THE 00222000240 2 1 010 00000000000000000000000000000 enne nnns 34 Defining a Connection u unu Qa hamana ike aa o E trennen ene tnen nne 34 Remote Download see Herde iere eee E
2. Defining a Connection 1 Click on Project gt Connection or click on the Setting button EA A Communication settings window will pop up Communication settings Mia serial port Cancel Baudrate 600 Flow control None Y Data bas E Stop bits 1 gt C Via Modem Modem xj Figure 16 PC Communication settings 2 Select a communication method If the communication is via serial port e Select Via serial option e Select the correct serial port from the drop down box e Select your port settings e Click on OK If the communication is via modem e Select Via Modem option 34 v REMMON RLite X2 e Select Modem from the drop down box e Clickon OK Remote Download To support communication between RLITE software and the RLITE unit a cellular modem needs to be connected to the PC that is running RLITE software 7 Note Ensure that both the RLITE s SIM and the PC s modem s SIM cards support CSD communication 7 Note If the RLITE s SIM and the PC modem s SIM are from different cellular service providers use the DATA IN number the phone number for using the CSD as the RLITE number in the RLITEs list on the Project Main screen Your cellular service provider should enable the SIM cards for CSD and inform you of their DATA IN number Setting up the Cellular Modem Before installing the cellular modem in your PC insert the SIM car
3. Out2 LOAD RJ12 Din4 Out3 LOAD DI GND T ag SIM POWER Back Panel Interface Power supply and relay output connector f OUT AH OUTB Relay output cabling Front Panel Interface 10 v lt REMMON RLite X2 Table 2 RJ12 Pin out Information 1 NA ANALOG ANALOG 2 Dini Analog input 1 Ain1 Dini 3 Din2 Analog input 2 Ain2 Din2 4 Din3 Digital input 1 Din1 Open Collector output OUT3 5 Din4 Digital input 2 Din2 Open Collector output RJ12 OUT2 6 6 6 GND Ground Warning X2 is floating device Make sure that no connection between the X2 unit and other electrical points Power Supply Cable Plug in the power plug into the power socket as shown in Figure 1 Relay output The RLite comes with one relay output Relay output can be activated or deactivated either by setting a predefined condition or by sending an SMS message from a recognized mobile phone When the Relay output is in active state then poles A and B at power connector see figure are connected To use the relay output follow these instructions Disconnect the power cable from both sides power and unit Uncover the cable near the unit side connector Cut the wire that bridge between pole A and B see figure 1 The two wires are the two poles of the relay switch 11 v REMMON RLite X2 D
4. Te He Ee reae dea aUe ae 35 Setting up the Cellular Modem eese e nrenne nennen trennen 35 Establishing a Connection with RLITE Unit sse 35 Downloading a Project 36 Uploading Projects s asua RH MORSU Rr ERROR Pet de cde 36 USING SMS TO COMMUNICATE WITH THE RLITE 37 INQUIRIES rhe ante eer E 37 DIRECTIVES 555 38 CONTACT INFORMATION ccsscsssssssssssessssccssscsssssssscsssscssssnesscsssessesssnssssssssscsnessessssssssssssessessoss 39 RLITE products USER MANUAL gt b b gt v REMMON RLite X2 Introduction Thank you for purchasing Remmon RLite GSM GPRS RTU system Please read this guide carefully to ensure proper installation Remmon is committed for providing the best cellular interactive monitoring solutions for your business If you need further assistance please contact Remmon Remote Monitoring at remmon remmon com or visit our web site at www remmon com For all contact information see page 39 Attention e Before using this product read carefully this manual e Allexamples and diagrams are intended to aid understanding and do not guarantee operation Remmon Remote Monitoring accepts no responsibility for actual use of this product based on these examples e Please dispose of this product according to local and nat
5. and priesh the button EE E lDocuents and SHOO mi Desitopist RelDemc Demo a Figure 5 Users sheet page Adding a New User 1 To add new user click on the Add button The Add user dialog box appears 2 Use the table below to set definitions for the new user Table 5 User Descriptions Field Description User name The name of the user User Phone The phone number of the cellular phone to which messages are sent 3 Click OK 7 7 Note You add up to 16 users Changing Deleting a User You can either delete a user or change its properties Deleting Go to the Users sheet page select the relevant user and click on Remove 18 v REMMON RLite X2 Changing to the Users sheet page click on Change In the Modify user dialog box change the user name or phone 19 v REMMON RLite X2 Working with Memory Fields Tags On the Memory page you can define I Os tags and other general purpose Bits which can be used as conditions within the RLITE or with other controllers To open the Memory page click on the Memory tab on the vertical toolbar at the right of the screen TT File Project Help jg J 2 5 812 22 Protocol type MODBUS op Name Adress Station Description Time System Tag Curent Time Register Date System Tag Curent Date Register DayOf Week System Tag PLC COMM System Tag Status of PLC communication V
6. button the Add condition dialog box appears 26 REMOTE MONITORING RLite X2 Add condition General Attach Values Logical condition mr r n SMS Message The main gate is open 74 le an Advanced gt gt Figure 10 Condition Definition VO Advanced 13 Use the table below to set your condition Table 8 Conditions Field Description Logical condition The logical expression which determines when a warning is sent to the specified users The expression consists of a Tag operator and a specific value its type depends on the selected I O type I O The I O on which the condition is based Note The I O drop down list contains some other items you may use as condition s base i e time Operator The operator of the logical expression Possible values Equal to the specific value Greater than the specific value Less than the specific value lt gt Not equal to the specific value 27 vx REMMON MONITORING RLite X2 Value Select the value in the logical expression its type and selection form depends on the selected I O type Send SMS on alarm On Select SMS on alarm on for sending SMS in case of event condition occurrence Send SMS on alarm Off Select SMS on alarm off for sending SMS in case of event s status inversion SMS text Type text that is sent to the
7. Digital Inputs The Counter increasing i 2 Counters connected to 2 of the DI De any upraise of the Relay Output Table 1 RLITE models The WEB option is refer to the log and server database option NOTE You can see the model type at the back of your device Y REMMON REMOTE MONITORING RLite X2 Description HW interfaces RS 232 RS 485 One DB9 male standard EIA Analog Inputs See models table page Digital Inputs Output See models table page Digital Output 1 Relay 1A at 12 24V Display 2 Leds red yellow Physical Characteristic Dimension 104 X 67 X 33 mm Weight 200 gram Assembly 2 screw handles Power supply Specification Power supply 9 24VDC 1A Active current 100mA Stand by current 30mA Protection According to MIL STD 704E Environment Operating Temperature 20 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 5 to 95 Protocols PLC protocols MODBUS Unitronics Microlog Hostlink Izumi and more ve REMMON RLite X2 Description Cellular Network Interface Band Two Band Tri Band Quad band Protocols CSD SMS GPRS class 10 Mobile station class B Internal modem Telit 864 Modem Approvals Fully type approved according to R amp TTE CE GCF FCC PCTRB IC Technology G
8. LITE via a PC you have to connect it to your PC thru the RS232 485 interface NOTE If you use the RS485 model you will need to use 485 to 232 converter The RLITE X2 serial port communication is in one of 2 options 232 or 485 The communication pins are described below Socket Pin 232 485 Name Description Name Description 1 CD Carrier detect 2 RX Receive 3 TX Transmit Data 4 DTR Data Data Terminal Ready 5 GND Ground GND Ground 6 DSR Data Set Read DB9 FEMALE 7 RTS Request To Send 8 CTS Clear To Send 9 RI Ring Indicator For 485 communication it s recommended to connect 1000 resistor between the and connectors For 232 communication between RLITE and it s recommended to use adapter as described below REMMON RLite X2 DB9 Male to Male 3 wire Adapter Pin No 2 gt lt 3 5 DB9 MALE v lt REMMON RLite X2 Cabling the R LITE X2 I O Analog Cabling Analog inputs Am Model PRO WEB 2 X2 Ain2 AUX Bins Sensor RJ12 p an r Digital inputs cablin Analog R LITE pintan All models X2 Din2 Ain2 AUX Din3 RJ 1 2 Ding DI GND Cabling Open collector output Model PRO WEB 20 R LITE bin X2 Din2 Ain2 AUX Din3
9. SM network SIM card Antenna Internal antenna MMCX External antenna MMCX Analog input Specification 2A models Number of input 2 Resolution bit 10 bit 0 02mA Conversion speed 10mS Input Current 4 20mA DC Precision 2 0 4mA Input impedance 1600 10 Digital input Specification 4 Number of input 2 2A or 20 Response time 20mS Minimum pulse width 1s Counter Specification 2C models Number of Counters 2 connect to 011 012 Maximum counts up to 65535 pulses each counter Open Collector Output Specification 2O models Number of input 2 Output type Open collector output Max current thru open collector 150mA va REMMON REMOTE MONITORING RLite X2 Relay Output Specification Number of output 1 Output type Relay 1A 30VDC 0 5A 125VAC Max switching voltage current 220VDC 1A 250VAC 1A Contact life cycle 200 000 operations minimum contact rating Minimum load 0 01 10 Contact resistance or voltage drop up to 50mQ Response time 3mS Data Logging WEB models Logger Memory 20KB Minimum Logging Interval 1 Minute Maximum Channels Sampling 10 Transferring Data Schedule Up to 5 tasks Transferring Data Destination REMMON website private user login Socket definition Compatible for DNS d
10. Settings kiDesktopRLtelDemclDemo rk Figure 13 Recipients Screen Selecting Condition s Recipients To reach the Recipient s screen 3 Click on the Recipient s tab on the vertical toolbar 4 Click the check box under the recipient s name which corresponds to the specific condition Click again to uncheck it 7 Note After you select a condition s recipients download the updated project information to the relevant RLITE refer to Downloading Data to an RLITE 31 RLite X2 RLITE Web models Advanced Settings The Web tab allows you to configure the sample rate the channels to be logged and the interval to dispatch the data into the web server File Project Help 812 Logging definitions 2 344 bog every 0 EM Total 3 days 11 hours and 20 minutes Name Description Time Curent Time Register Date Curent Date Register DayOfWeek PLC COMM Status of PLC communication Din1 Din2 AN1 Internal analogue input AN2 Internal analoque input OUTI Internal Digital Output v v x x v H v L V cO CO C C CO n9 Publish data schedule Description nri Interval of 5 minutes starting when unittum on Slusidisey suonipuoo Mowe sJes eia Change Remove CidelmeiRealwebiRealwWeb rlt Figure 14 Web Screen Selecting Channels and Logging Rate To reach the Web screen 1 Click on the Web tab on the v
11. The RLITE products MODEL X2 User Manual v lt REMMON REMOTE MONITORING Version 3 4 26 MAY 2009 v lt REMMON RLite X2 Table of Contents INTRODUCTION 1 REITE LED 6 HARDWARE INSTALLATION 7 SIV CAR Docenia AAAA 7 ANTENNA E A A A E E E E E T 7 POWER SUPPLY CARLE curcia 11 RELAY OUTPUT 11 DIGITAL INPUT 12 ANALOG INPUT ONLY AT 2 12 THE APPLICATION 13 PROIECE 13 Creating New Projet th kept eem n en EpL ree E otn rere ai 13 MITTUNT 17 Viewing a Project s Properties enne nnns 17 INE W USER S 18 Adding New User aseo re re ere CHER TEE EDO Td Y ae 18 Ch nping Deleting aUser eoe iie pi a ie VENE Hie ERO FE Ue eee 18 WORKING WITH MEMORY FIELDS 5 20 Default 21 PAGING
12. be downloaded to the RLITE unit to become valid Uploading a Project 7 Warning Uploading data prom the RLITE unit to an open project will erase all previous data on that project In order to upload a project from the RLITE unit you must open a project 1 Click New project or open an existing one 2 Click Upload button 3 Wait a few seconds till the upload process is completed 36 v REMMON RLite X2 Using SMS to communicate with the RLITE After a successful download you can put the RLITE into work Only users which had been defined in the RLITE configuration settings can communicate with the RLITE A typical RLITE user can either get warning SMS messages from the RLITE or send inquiry directive SMS messages to the RLITE Inquiries With the RLITE in the field you can check for the current value of each of its Tags Each user defined in the RLITE configuration can send an inquiry SMS message with the following format lt Tag s name gt 7 Note You may concatenate in one SMS more than one request in the following format 2 lt tag name 1 gt lt tag 2 gt Examples To get the current time of the RLITE send an SMS message to the RLITE SIM card number with the following text Time To get the time and date of the RLITE send an SMS message with the following ftext Time Date To get the current value of digital input 1 send an SMS messag
13. d into the modem so that the modem can transmit and receive data via the cellular network For instructions regarding installation of the SIM card refer to the modem s documentation The modem is connected to the PC with a 9 pin D shell cable To connect the modem to the PC 1 Connect the female end of the 9 pin D shell cable to the PC that is running RLITE SOFTWARE 2 Connect the male end of the cable to the cellular modem Establishing a Connection with RLITE Unit 1 Click on the Users tab on the vertical toolbar to open the Users List screen 2 Enter your password 7 Note For the initial connection to the RLITE unit enter the default password 000000 six zeros 3 Click the Connect button 2 35 v lt REMMON REMOTE MONITORING RLite X2 4 Wait a few seconds A green RUN indicator on the bottom left of the screen will confirm your connection 7 Note After establishing connection you can change the password by typing a new six letter password and clicking on the Change password button Downloading a Project After designing a project you must download the project to the RLITE unit 7 Note Before downloading a project make sure you have established a connection with the RLITE unit 1 Click the Download button 3 2 Wait few seconds till the download process is completed 7 Note After making changes to the project it must
14. e date to August 11 2007 one should write 11 08 07 If it is now August 11 2007 and the time is 16 30 then set the time and date by sending the following SMS text ITime 16 30 date 11 08 07 To turn on the output relay send an SMS message with the following format lt the name of the relay output gt 1 The default name for the output relay Tag is Out during RLITE configuration one may want to rename some or all of the Tags If the default name of the relay output hasn t been changed then one may turn it on by sending the following SMS text IOUT 1 Alternatively to turn off the relay output send the following SMS text IOUT 0 38 Y REMMON REMOTE MONITORING RLite X2 Contact Information Address Industrial Area Beit She an Israel 10800 Email remmon remmon com Phone 972 4 6065815 Fax 972 4 6065819 Website www remmon com 39
15. e with the following format lt the name of digital input 1 gt The default name for digital input 1 Tag is Dini during RLITE configuration one may rename some or all of the Tags If the default name of digital input 1 hasn t been renamed then a user may get its current value by sending an SMS message with the following text Din1 7 Note The Header in SMS must be exactly like the header as configured at software include capital letters if there is 37 v REMMON RLite X2 Directives With the RLITE in the field you can change or reset each of its Tags Each user defined in the RLITE configuration settings can send a directive SMS message with the following format I lt tag s name gt lt value gt 7 Note After RLITE sets the new value a notification message is sent to your cellular phone 7 Note You may concatenate in one SMS more than one set command in the following format l lt Text 1 2 value 1 Text 2 gt lt value 2 gt Examples To set the RLITE time to a specific hour a user can send an SMS message to the RLITE SIM card number with the following format ITime HH MM To set the time to 16 30 the user should send SMS message to the RLITE Sim card number containing the following text ITimez16 30 To set the RLITE date to a specific date a user can send an SMS message to the RLITE SIM card number with the following format IDate dd mm yy To set th
16. efinition R LITE Approvals CE RoHs compatible vE REMMON RLite X2 RLITE LED RLITE contains two LEDs on the front panel Table 2 describes the PWR LED indications Table 1 PWR LED Indications Description State Fast blinking then 20 Initialization after reset second Off Periodical Blinking 2 Empty database No project in seconds On 1 2 second Off RLITE unit Periodical Blinking 12 Operational state second On 2 seconds Off Periodical Blinking 1 Connection state with PC second On 1 second Off and 5 fast blinks Fast blinking Sending SMS Periodical Blinking 1 Pipe Gateway state Transferring second On and 10 fast data from PLC device to PC with blinks cellular modem and vice versa vE REMMON RLite X2 Hardware Installation SIM Card To send and receive an SMS you need a valid SIM card Insert the SIM card into the SIM slot on the back panel as shown in Figure 1 Antenna Plug in the GSM antenna by connecting the MMCX plug into the ANT socket Warning RLITE PRO is floating unit B Make sure that no connection between the RLITE PRO unit and other electrical points 545 REMMON RLite X2 Communication Port The RS232 485 port can either be used for connecting the RLITE to a PC or toa PLC Using this port you can program the RLITE via your PC or you can read data from your PLC To program the R
17. ertical toolbar appears only if the project belongs to the Web type 2 Select the logging rate using the up down buttons in the Logging Definitions box at the top of the screen The minimum rate is 1 minute 3 Click on the channel name to be logged at the RLITE Web To deselect the channel click on the channel name again 7 Note The RLITE Web supports only 10 channels to be logged 32 RLite X2 Defining Dispatch Tasks Dispatch task is a periodical event for sending data to the web server To define a Dispatch task 1 Click on the Add button The Scheduled Tasks dialog box appears Scheduled Tasks Preform this task Daily Weekly C Monthly C When unit starts Figure 15 Scheduled Tasks dialog box 2 Select the task performing periodicity and follow the on screen instructions 3 Click on Finish to complete the task setting Z Note The RLITE Web models supports up to five scheduled tasks 7 Note Confirm that the RLITE Web date and time are accurate because the Scheduled Tasks feature relies on this information to run scheduled tasks 33 v REMMON RLite X2 Downloading Uploading Connecting with the RLITE To upload or download a project you must define your connection with the unit via the serial port of your PC or via a cellular modem 7 Note Ensure that the hardware is properly connected
18. igital Input The RLITE is equipped with two Digital Inputs Din 1 2 which can monitor dry contact sensors The digital inputs are provided thru Din1 2 and GND wires see Information Table for RJ12 pin out Digital input 1 2 Din 1 2 are said to be in Active 1 state if GND and Din1 2 wires are connected otherwise it said to be in Inactive 70 state 7 Note In the conditions statements High and Low correspond to Active Inactive states Analog input only at 2A models The RLITE is equipped with two 4 20mA Analog Input The sensor device can either get power from the RLITE or from external source The 4 20mA current is to be converted into numeric values ranging from 0 65535 0 Hex The numeric value be converted into engineering values in respect to preconfigured calibration initiated by the user 12 v REMMON RLite X2 The Application Software Project project or simply a project is a computer file with an rlt extension The RLITE application software can either create a new project or open an existing one A project is the RLITE basic working environment It is a platform where you can edit your settings and download them to the RLITE When the project is set it can be downloaded to the RLITE thus configuring the RLITE behavior Creating a New Project To create a new project 1 Click on File gt New 2 or click on the New project but
19. ion protocol with the PLC Parity Select Parity bit for communication protocol with the PLC DataLen Select Data length Bits for communication protocol with the PLC StopBits Select Stop Bit for communication protocol with the PLC 8 Click on Next A confirmation window summing all the project configuration settings appears 9 Review your settings 10 Click on Finish 16 v REMMON RLite X2 Opening a Project 1 Click on File gt Open or click on the Open project button The Open project dialog box appears 2 Browse to the project directory select your project and click on Open 7 Note To reopen a project go to the menu bar and click on File gt project name Viewing a Project s Properties To view your project properties 1 On the menu bar click Project gt Properties 2 Click on Next gt Finish 17 RLite X2 New User s Users are the cellular phone subscribers who can control and receive messages from the RLITE unit To open the Users sheet page click on the Users tab on the vertical toolbar on the right of the screen moet 2518 815 2 Be 7 User name Userphone Mickery 05443210 I 622 Sen 05456554 2 3 5 5 s v 2 2 5 Add Change Remove La s Password 000000 Change password Fot change the password connect to unit change the password
20. ional standards and regulation e Only qualified service personnel should open this device or carry out repairs Warning The RLITE is floating unit Cosy Make sure that no connection between the RLITE unit and other electrical points Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not install in areas with excessive or conductive dust corrosive or flammable gas moisture or rain excessive heat regular impact shock or excessive vibration Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation vE REMMON RLite X2 THE RLITE X2 PRODUCT FAMILY The RLite X2 product family gives you variety of option to suit your needs below a table that define all products All models can be with one of two communication interface options RS 232 or RS 485 RLITE X2 4 Digital Inputs 1 Relay Output RLITE X2 PRO 2A 2 Analog 4 20mA inputs Two nonlinear 2 Digital Inputs calibration table to both Analog inputs 1 Relay Output RLITE X2 PRO 20 2 Open Collector Outputs 2 Digital Inputs 1 Relay Output RLITE X2 WEB 2 2 Analog 4 20mA inputs 2 Digital Inputs Relay Output RLITE X2 WEB 20 2 Open Collector Outputs Not include nonlinear 2 Digital Inputs table 1 Relay Output RLITE X2 WEB 2C 4
21. n Settings dialog box only at Web models 5 Fill in the fields as described in the following table Table 3 Communication Settings Field Descriptions Field Description APN context Connection string supplied by the cellular provider of the SIM card The string must start and finish with quotation marks User name Username supplied by the cellular provider of the SIM card The string must start and finish with quotation marks Password Password supplied by the cellular provider of the SIM card The string must start and finish with quotation marks Server socket Connection string supplied by your Default supplier The string must start with 55123 m2m remmon com the Socket number and then the IP string started finished with quotation marks 6 Click on Next The PLC and Communication Protocols dialog box appears 15 v lt REMMON MONITORING RLite X2 New project PLC Type Jx MODBUS Scan period 16 S second Baud Parity DataLen StopBits Cancel PF a Ro s Back Figure 4 PLC Communication Protocol dialog box 7 Fill the fields as described in the following table Table 4 PLC and Protocol Field Descriptions Field Description PLC Type Select PLC protocol Scan period Select the period of time between the PLC s data scans by the RLITE unit Baud Select baud rate for communicat
22. n with unit Figure 7 Advance Calibration 5 The linear conversion is to be determined by mapping two different engineering values one to the lower electric value 4 mA and one to the upper electric value 20 1 At the upper textbox insert engineering value This value is to be mapped to the lower electric value e g connecting sensor that 4ma goes to 20C type 20 2 At the lower textbox insert engineering value This value is to be mapped to the upper electric value e g connecting sensor that 20ma goes to 100bar type 100 6 While connected to unit you can fine tune your calibration online by adjusting your linear conversion The Current value display box shows the current engineering value online with respect to your linear conversion The new calibration takes effect after Data download 23 v lt REMMON REMOTE MONITORING RLite X2 To carry out nonlinear transformation Non Linear transformation refers to linear sensors that measuring non linear values e g liquid level sensors corresponding to cylinder tank volume 1 2 3 4 The table window appears Select the VOL1 2 tag from the memory list Click change or double click on the table sheet At the change window click advanced ajx S pe Vae Eng Vale Figure 8 Conversion Table For any calibration point click on new row Insert the sensor s electric output value ranging from 4 20mA and its corres
23. olt RLite Analogue i Power supply Din1 RLite Digital Input Internal Digital Input Din2 RLite Digital Input Internal Digital Input Out RLite Digital Out Internal Digital Output ANI Analogue i Internal analogue input AN Analogue i Internal analogue input YOLI RLite Nonlinear Nonlinear calibration of analogue input Nonlinear Nonlinear calibration of analogue input sasn eia 5 5 D F ICO sjueidi28 4 suonipuoo j STOP a iC iDocuments and Settings maoz Desktop test projectslX2protestinewlnew rlt Figure 6 Tags List 20 REMMON RLite X2 Default Tags The Memory tab contains default tag names assigning tags to the RLITE specifications as described in the table below for model X2 The default Tags will appear ac at the unit definition dialog box pue to your unit model that had chosen Table 6 Default Tags Tag Description Dini Digital input 1 Din2 Digital input 2 Din3 Digital input 3 Din4 Digital input 4 AN1 Analog input 1 AN2 Analog input 2 VOL1 Nonlinear calibration for analog input 1 VOL2 Nonlinear calibration for analog input 2 C1 Counter 1 connect to 1 C2 Counter 2 connect to Din2 OUT2 Open collector output 1 OUT3 Open collector output 2 OUT1 Relay output Time Time register Date Date register DayOfWeek Day of the week regi
24. ponding engineering value Repeat steps 5 and 6 to complete the conversion table To edit a row click on modify row You load existing table by clicking on load table 24 v REMMON RLite X2 Changing Removing a Tag 10 Select the relevant Tag from the memory list 11 Click Change or Remove button 7 Note You cannot change or remove a system s default tags 7 After you define add or remove new tag download the updated project information to the RLITE unit refer to Downloading or uploading a project 25 RLite X2 Working with Conditions Setting conditions allows you to configure the behavior of your RLITE on a given event It is a logical mechanism through which you can specify events that will trigger sending an SMS You also specify the recipient of the SMS if output relay is going to be opened closed and more To set a new condition as well as modify an existing one click on the Conditions tab on the vertical toolbar on the right of the screen The Condition sheet page will appear Efe Project Heb img 91312 we 24 Logic Text alarm Quent Text OK Quant Attach 1 DayOfWeek 0 Weekly check Once Nose YES i532 Din1 1 The main gate is open 2 Nose Aowa sies 1461 Add Change Remove Figure 9 The Condition sheet page Adding a New Condition 12 Click on the Add
25. specified users cellular phones 14 For advanced properties click on the Advanced button The Advanced properties dialog box appears Advanced Sending settings Stabilitytime b 20 2 fo 2 ii ipp a PEU Send it times Every ET Operate output by condition min Out1 Not activated r Wait stability time Cancel OK Figure 11 The Advanced dialog box 15 Use the table below to complete the Advanced dialog box REMOTE MONI vx REMMON RLite X2 Table 9 Advanced Properties Field Description Stability time The amount of time during which the condition s logical expression must be true before an SMS is sent Send it xx times The number of times the message will be sent to each recipient Every The time passed between sending the messages Out 1 Relay output activation by condition Open for open relay contact Close for relay contact Wait stability time Mark this option in order to wait stability time Attaching Values To select any additional value s to be sent to your cellular phone with the text for this condition Modify condition E 1 Click on the Attach Values tab General Attach Values X Date X DayOMWeek XPLC COMM Cellular screen Figure 12 SMS Report 29 v REMMON RLite X2 2 Click the value Name A mark will appear ne
26. ster PLC COMM Communication regularity status 0 for communication in order 1 for communication abnormal 7 Note Make sure that your PC time and date clock is correct When downloading the RLITE clock automatically synchronized with your computer time and date clock Also the RLite take clock from the cellular network any time the unit powered on 21 v lt REMMON RLite X2 Adding a New Tag 1 Click on the Add button The Add tag dialog box appears 2 Use the table below to complete the dialog box Table 7 Tag Descriptions Field Description Name Tag s name which will be used for SMS feedback and reports Address Tag s address in the PLC Station PLC s Number Type Tag s type derived from protocol s properties Description General tag s description 3 Click OK for adding this tag to the memory map The new tag appears in the memory map list 7 Note You can add up to 100 tags 22 v REMMON RLite X2 Analog inputs calibration 2A models Linear conversion and sensor calibration AN1 1 Select the AN1 2 tag from the memory list 2 Click change button or double click on the table sheet 3 At the change window click advanced button at the bottom right side 4 The advanced calibration window appears Advanced Calibration X OK 4ma o Cancel 20 ma 4 Current value On line No communicatio
27. ton The New project dialog box appears New project DAK Name Demo Save in C RLite gt gt 25 Documents and Settings gt miki Cancel Figure 1 New Project 2 In the name textbox type in a name for your project choose a directory path and click on Next The Unit Definition dialog box appears 13 v REMMON RLite X2 Dixi Unit model m Unit phone 05480516 1 Description DEMO for manual Cancel lt lt Back gt gt Figure 2 Unit Definition dialog box 3 Fill in the fields as described in the following table Table 2 Unit Definition Descriptions Field Description Unit Model Click on the down drop list to select your RLITE model Use table 1 RLITE models and the label at the back of your device Unit phone Insert the unit phone number as ascribed to the SIM card in use 7 Note To configure the RLITE unit via cellular modem must provide a valid phone number Description Free text describing your project 4 Click on Next If the unit model is RLITE Web then Communication settings dialog box appears If not then PLC and Communication Protocols dialog box appears 14 RLite X2 Properties BAA 1 APN context Cien 0 0 User name web Password l webi23 Server socket 55123 m2m remmon com Cancel lt lt Back Next gt gt Figure 3 Communicatio
28. xt to the value and the value will also appear in the Selected list The Cellular screen window simulates how the condition message with its values will be displayed on your cellular phone The marks the parameters value digits 3 Click on OK The new condition appears in the Conditions List 7 Note After defining a condition you must associate users as recipients for the condition refer to Associate users as conditions 7 Note After you defining conditions download the updated project information to the RLITE Changing Removing a Condition If you no longer want RLITE to send warnings for a particular condition you can delete the condition from the project 1 Select the relevant condition from the Conditions list 2 Click on Change or Delete button 7 Note After you changing or deleting any condition you must download the updated project information to the RLITE refer to Downloading Data to an RLITE 30 RLite X2 Associating Users as Condition s Recipients Recipients are the selected users that receive the conditions SMS Each condition may have its own selected recipients Projet acm Osis wel 2 Condition gt NI 1 2 Din1 1 Fx S e Oo 3 2 o 3 a gt uv 2 o 2 C Documents and