Home
Owner`s Booklet
Contents
1. L i Q Temperature Error mid Aaa Month Date Aga Time check Check Strip V Special Result Unit of Measurement Low Battery Warning After Meal Mark After drug Ieg Ready to Test I The Test Disinfection Before Test O ji Before test please clean hands with soap and water and then dry well a You can also use an alcoholic cotton cloth to clean the finger Please wait until the alcohol disappears completely Insert Glucose Test Strips Insert a Test Strip Insert a test strip into the strip slot You will hear the sound of beeper Strip and Blood Symbol The display screen will show the strip and blood symbol 3ized When the Strip and blood symbol appears the meter is ready to test for you a Please start test according to the common method please read the details in the page 15 The Method of Blood Collection Unscrew the tip of the lancing device by turning it counter clockwise While holding the lancet carrier insert a new sterile lancet into the bottom of lancet carrier Twist off the cap of the lancet Put the tip of the lancing device back on and turn it clockwise Get blood sample Before testing wash your hands thoroughly with warm soapy water Rinse and dry completely Hold the lancing device firmly against the side of your finger Press the release button Never use
2. distributor or manufacturer 32 The meter does not work after inserting test strip a Make sure test strip inserts into the strip slot completely a Make sure the battery shows positive sign facing upward a Replace the battery 33 Causes Solutions The meter does not work after the blood is applied m Make sure test strip inserted into the test strip slot completely Make sure the blood applied to the test strip correctly m Make sure the test strip inserted direction is correct and repeat test Test result is abnormal Check whether the test strip has foreign bodies adhered or exposed for long time Check whether the test strip is used Check whether the test strip has become invalid Check whether the test strip vial opened date has passed more than 3 months 34 Warranty The makers guarantee that the Veri Q MGD 1001 Blood Glucose Meter shall be free of defects in material and workmanship for a period of five years This guarantee is valid from the date of purchase The guarantee extends only to the original purchaser and is not transferable The warranty ceases to apply under the following conditions a The meter is damaged as a result of incorrect use a The meter is damaged as a result of natural disasters e g typhoon earthquake and so on a The meter is damaged as a result of demolition a The meter is damaged because you use products which ar
3. drop to form Continue holding the sampler against the skin for a few seconds until the blood drop forms Allow enough blood to form under the cap until you have a blood sample that is sufficient to fill the confirmation window of the test strip If you must massage the area to obtain more blood do not squeeze the site excessively 41 Symbols A e Note Caution Manufacturer Batch code Temperature Catalogue In vitro Diagnostic Limitation Number Desclly Medical Device S ta Snan 2 Do not reuse WEEE Directive C oin EN CE Mark reg Authorized Representative in the European 5 IVDD 98 79 EC Community Serial Number EMC Test Results This equipment complies with EN 61326 2006 Class B requirements and the emissions of the energy used are low and not likely to cause interference in nearby electronic equipment The equipment is tested for immunity to electrostatic discharge at test level 2kV 4kV and 8kV of air discharge The equipment is tested for immunity to radio frequency interference at the frequency 80MHz to 2 7GHz and test levels 3V m 42 e Disposal of Used Electrical amp Electronic Equipment The meaning of the symbol on the product its accessory or packaging indicates that this product shall not be treated as household waste Please dispose of this equipment at your applicable collection point for the recycling of electrical amp electronic equipments waste In the European Union and Other Europ
4. is too hot or too cold for the system to work properly The operating temperature should be 50 104 F 10 40 C Please use system after about 20 minutes The blood sample is not filled enough for measurement because of abnormally high viscosity or insufficient volume Repeat test with a new test strip 31 Hi Lo Messages Messages Descriptions Solutions When the test result is higher than 600 mg dL 33 3 mmol L the screen will show the Hi mark it indicates that the value of your blood glucose is too high Replace the test strip If Hi mark appears again please call your healthcare professional immediately In the event of a problem with the meter or an error message please contact the distributor or manufacturer The test range of Veri Q Blood Glucose Meter is 20 600mg dL 1 1 33 3 mmol L Causes Solutions When the test result is lower than 20 mg dL 1 1 mmol L the screen will show the Lo mark It indicates that the value of your blood glucose is too low Replace a new test strip If Lo mark appears again Please call your healthcare professional immediately The thermometer mark 4 appears on the screen Put the meter and test strip into the environment of temperature 50 104 F 10 40 C You should use it after about 20 minutes a f the thermometer mark always appears on the screen please contact the
5. Veri O_ Blood Glucose Monitoring System MGD 1001 Owner s Booklet Veri O_ CE 0120 2011 MiCoBioMed All rights reserved MiCoBioMed Co Ltd gee 55 13 Shingeonji dong Anseong si Gyeonggi do 456 781 Korea www micobiomed com Made in Korea MT PROMEDT Veri Q is the trademark of MiCoBioMed All other product names and trademarks are the property of their respective Rev 1 201111 MiCoBioMed I Welcome Thank you for selecting the Veri Q MGD 1001 Blood Glucose Monitoring System Follow the steps for using the system in this manual Before using your monitoring system for the first time please read this manual carefully Intended use This Veri Q MGD 1001 Blood Glucose Monitoring System is intended for the quantitative measurement of the concentration of glucose in whole blood from fingertip ventral palm and forearm by diabetic patients or healthcare professionals as an aid in the management of diabetes It is intended for use outside of the body in vitro diagnostic use and not for diagnosis of or screening for diabetes nor for use on neonates or arterial blood The alternative site testing ventral palm and forearm in this system can only be used during steady state blood glucose conditions Application Veri Q MGS 01 and MGS 01B Test Strips are for in vitro diagnostics use only The Veri Q MGD 1001 meter is not a substitute for your healthcare professional Use the Veri Q MGD 1001 Meter in conjunction with
6. a lancet that has been used by someone else Do not leave the lancet in the device after use and discard properly a If the lancet cap has loosened or fallen please don t use it 14 Add Blood Sample Touch the blood drop to the sample channel at the end of the strip When you hear the beeper you can start the test After 5 seconds the result will appear Touch the blood Don t drop the drop to the sample blood to the strip channel at the end of the strip Proper Blood Sample O x aThe amount of The amount of blood sample is blood sample is sufficient insufficient The sample channel at the end of the strip should be covered with blood When you hear the sound of beeper The blood sample is adequate Please don t drop the blood directly on the end of the strip When the blood sample is not sufficient the display screen will show the message of Er 3 Please refer to error message in this manual Processing the Test Result Z The test result will appear after the meter im counts down 5 seconds om During countdown please don t shake it my mid 4 a After showing the test result please take the A I0 52 strip out 5 seconds after drawing blood sample You can l hear the sound of beeper and the screen will C show test result date and time 4 After taking the strip out the meter will be ie ite turned off automatically f t
7. ake out the old Put the new u Turnthe battery lid battery battery CR2032 off Press the into the battery battery lid down slot and make sure until you hear the battery shows sound Tic positive sign facing upward f you replace the battery while the meter is on the time need to be reset The meter can t be turned on when the battery mode doesn t match the meter or the battery isn t installed correctly 29 Cleaning Veri Q Blood Glucose Meter Caring for your Veri Q Blood Glucose Meter is easy just keep it free of dust If you need to clean or disinfect it please follow these guidelines carefully to help you get the best performance possible Make sure the meter is off Gently wipe the meter s surface with a soft cloth slightly dampened with one of these cleaning solutions Super sani cloth 70 isopropyl alcoho Mild dishwashing liquid mixed with water 10 household bleach solution 1 part bleach plus 9 parts water made the same day Make sure you squeeze off excess liquid from the cloth before you wipe the meter s surface AN Do not spray any cleaning solution directly onto the meter Do not put the meter under water or liquid Do not pour liquid into the meter 30 Troubleshooting Error messages Messages Descriptions Solutions Test strip is used or Replace a new test strip E iP f damaged mid 4 228 06 28 3 ey Ere 229 0529x Temperature
8. d time Press P button and the screen will display if there is last test results After completing the check press M button to turn off the meter Press and hold P button for 2 seconds the speed of test results will be accelerated and the screen will be changed quickly 20 Setting Mode Press M button for 2 seconds you will hear the beep the screen will show the whole symbol of system After 1 second the display screen will show the picture above The Setting Sequence of the Date Time and Checking Units Setting Setting Setting Setting the Month gt the Date gt the Time gt the Hour Format Q Q Q Q Setting lt 4 Setting g Setting lt a Setting the Memory the Sound the year the Minute 21 EE m w 0 ie HES LLi l L I mgldL mid w we aly a l E I mgldL m d us Ge igh JIN Setting the Month When month mode blinks press and release P Button until correct month appears Press M button to set and move to date setting mode Setting the Date When date mode blinks press and release P Button until correct date appears Press M button to set and move to Time format setting mode Setting the Time Format The meter can be set in 24 hour format default format When time mode blinks press button to shift to AM PM 12 hour After choosing the time mode pr
9. e not compatible with our products 35 Technical Specification Product Name Veri Q Blood Glucose Monitoring System Meter type MGD 1001 Blood Sample Fresh capillary whole blood Blood Volume 0 5 yl Test Strip Type Veri Q MGS 01 and MGS 01B Measuring Range 20 600 mg dL 1 1 33 3 mmol L Measuring Time 5 seconds Power One 3V Lithium Battery type CR2032 Battery Life Approximately more than 1000 tests Memory Capacity 450 test results include date and time Operating Temp 50 104 F 10 40 C Operating Humidity 10 90 RH Storage Temp 46 86 F 8 30 C Dimensions 57 X 70 X 17 mm Weight 36g with battery 36 Diagnostic System Control solution test Veri Q control solution is a optional product The control solution test confirms that your meter and test strips are working correctly A control solution test is similar to a blood glucose test Except using Veri Q control solution and not a blood sample Users should periodically compare the test system to another test system known to be well maintained and monitored by a healthcare provider You should run a control solution test When you first get your Veri Q MGD 1001 Meter When you open and begin using a new test strip vial a f you feel your test results are not accurate or if your test results are not consistent with how you feel If you leave the test strip vial ca
10. ean countries which there are separate collection systems for used electrical and electronic product By ensuring the correct disposal of this product you will help prevent potentially hazardous to the environment and to human health which could otherwise be caused by unsuitable waste handling of this product The recycling of materials will help conserve natural resources Therefore please do not dispose of your old electrical and electronic equipment with your household waste For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product 43
11. ess M button to set and move to hour setting mode 22 Setting the Hour When hour mode blinks press and release P Button until correct hour appears Press M button to set and move to minutes setting mode Setting the Minutes When minute mode blinks press and release P Button until correct minute appears Press M button to set and move to year setting mode Setting the Year Entering the year mode the screen will show the number of year for example this number stands for the year of 2011 Press and release P button until correct year appears Press M button to set and move to sound on off mode oe mid JIN 45 Bae ay 23 Setting the Sound When sound symbol mode blinks press and release gt Button You can choose sound on off Press M button to set and move to memory setting mode Consult your healthcare professional if you have any questions about blood glucose measurement units Use of the wrong glucose measurement unit may cause you to misinterpret your blood glucose level and incorrect treatment You must make sure about glucose measurement units before the test 24 AC OIL Ln mid mem CD 830 AF mm Vha m d mem CD BIG GY UCC Rien a BIG MY m Hle HRDO Ga S Setting the Memory When memory mode The screen will show and blink dEL letters You can press Button to switch your
12. he test result is abnormal please use a new test strip to test again Also if the test result has a problem please refer to the Troubleshooting in this manual Processing the Test Result f you don t want to store test results or control V I m E solution test results please press M button I C You can show the symbol V in the screen mg dL an ap Pi mid D After turning off The meter will not store the m a 1 test results LLI ICi w een If you want to mark test results after meal or AN medicine please press gt button You can or n n we tl I mga SOW changed the symbol Q or in the screen mid ii kat After turning off The meter will store the test results Se a O an es _ l Mi I The Use of Function Buttons Checking Test Results Begin with the meter off Press M button and you will hear the beep and the meter will be turned on After 2 seconds the last 14 days average result m J will be displayed I mem YG cn f you don t make any changes the meter will be turned off automatically after 3 minutes 1m MCVIE oa mid mem 4 cc Obch apy IC mid mem a i 0S5 jm a Press P button one time the screen will show the most recent test result date and time Each time button is pressed the screen will show the previous test result date an
13. he test strip is 20 months under seal and the validity is 3 months open vial Please protect test strips to maintain validity Don t reuse the test strips The Veri Q MGS 01 or MGS 01B Test Strips is or one time use only This product is not recommended for pregnant women newborns or people under severe dehydration Be sure to check the glucose measurement unit on the meter before the test eep away from direct sunlight and heat Don t refrigerate or freeze test strips Don t use test strips past expiration date AN Veri Q MGD 1001 Meter is for use only with Veri Q MGS 01 and MGS 01B Blood Glucose Test Strips I Safety Information Inaccurate results may occur for individuals or patients in shock Inaccurate results may occur for individuals experiencing a hyperglycemic hyperosmolan state with or without ketosis Critically ill patients should not be tested with a blood glucose meter Before using the system please read this manual carefully The meter and test strips should be handled at the same temperature For accurate results keep the Veri Q MGD 1001 blood glucose monitoring system at test place under the operating temperature 50 104 F 10 40 C for more than 20 minutes before testing The Veri Q MGD 1001 Blood Glucose Monitoring System shows accurate results between 50 104 F 10 40 C Do not store the meter test strips lancing device and lancet in a place where the children can reach easil
14. ood sugar is low You are not aware of symptoms when you become hypoglycemic The site results are not consistent with the way you feel After a meal After exercise a During illness During times of stress Alternative Test Site a y Ne J Forearm Ventral palm 39 Use alternative site testing only two hours or more after taking insulin two hours or more after a meal two hours or more after exercise Do not use alternative site testing if you are pregnant or if you are aware that your glucose level is not as stable as usual or if you think you have hypoglycemia low blood sugar or hyperglycemia high blood sugar or at times when you think your blood glucose may be rising or falling rapidly Do not use alternative site testing if your alternative site testing results do not match the way you feel 40 Alternative Test Site sampling Step1 Choose the Puncture site Select a soft fleshy area on your forearm or ventral palm those are clean and dry away from bone and free of visible veins and hair Step2 Massage the Area To increase blood flow to the puncture site massage the area gently For individuals who experience difficulty in getting sufficient blood for a test rubbing the area more vigorously or applying heat briefly may be helpful Step3 Position the sampler Press and hold the sampler against the arm for a few seconds Press the release button Step4 Allow blood
15. options no or yes for deleting test results or not If you want to remain the stored test results please choose the symbol NO And Press M button again to move to the month setting mode If you want to escape setting mode press and release M button for 2 seconds or just remain for 3 minutes If you want to delete all test results press M button when the screen shows the symbol YES All the test results will be deleted After 3 seconds the screen will show no test results After complete setting press M button for 3 seconds the meter will store the setting and it will be turned off When the number of stored results is more than 450 the oldest stored result will be deleted and the new result will be stored 25 Setting Complete m d mem BES 66 check f EA soon all LI mmol L 50 58 68 68 After complete setting press M button for 3 seconds the meter will store the setting and it will be turned off No matter which steps the meter sets it will store the recent setting and be turned off when you press and hold M button Special Results m d mem ceg Obch The mark for control solution test results a You can use this function when you want to remember the result under control solution test conditions When the screen displays the test result press M button after tests the symbol W mark appears And then you can take the test strip out
16. p open for any length of time The Veri Q Control solution range is printed on the test strip vial Check the expiration date on the control solution vial Do not use control solution past the expiration date 37 Check Strip test The Check Strip Test confirms that your meter is working correctly The check strip only tests the function of the meter and not the ability of test strip to render a result or the accuracy of the system as a whole To test the entire system please rely on the results from testing a control solution Step 1 Begin with the meter off condition insert the Check Strip to the meter s test strip slot Step 2 If the meter doesn t display YES message after inserting check strip please contact the distributor or manufacturer Excessive use of check strip may cause the damage of meter s strip slot Please use the check strip only when you think the meter is working improperly 38 Important information Alternative Site Testing AST Contact your healthcare professional before you begin using any one of these alternative sites to test your blood glucose Alternative site results may be different from fingertip results when glucose levels are changing rapidly e g after a meal after taking insulin or during or after exercise Do not rely on test results at an alternative sampling site But use samples taken from the fingertip if any of the following applies You think your bl
17. r home usage Accurate result in 5 seconds with using only 0 5 al blood sample Large display screen Store up to 450 test results Blood glucose measurement units are pre set in mg dL or mmol L Use of the wrong unit of measure may cause you to misinterpret your blood glucose level and may lead to incorrect treatment I Cautions Usage and Storage Before using your monitoring system please place it in the environment with the system s normal operating temperature ranging 50 104 F 10 40 C for about 20minutes 1 Don t allow dust and foreign bodies into test strip slot in order to avoid affecting the system s accuracy Don t decompose demolish repair or transform the system at any ime Don t put the system near any electromagnetic field e g TV microwave oven mobile phone Don t allow the monitoring system to collide with others during usage eep away from direct sunlight and humid environment for an extended period of time Please use a soft cotton cloth to wipe the system Don t use a corrosive product e g Benzene Acetone to wipe the monitoring system I Cautions regarding the MGS 01 or MGS 01B Test Strips Store bottle in a cool and dry place between 8 30 C 46 4 86 F Take test strips out with clean dry hands for accurate results Use test strips immediately after retrieving from the vial and to keep the test strip vial tightly closed at all time The validity of t
18. the meter is turned off and the test result is not stored 26 The mark for results after meal 10 c m This mark can be used when you want to I lee istinou r distinguish results such as test results after meal mid mem A as 04 052gm After the test result displayed press button once with the test strip inserted then Y appears And you can take the test strip out the meter is turned off and the test result is stored automatically The mark for results after medicine I ILI m This mark can be used when you want to akl l hlo distinguish results such as test results after m d mem 4 p9 0528m medicine After the test result displayed press button twice with the test strip inserted then appears And you can take the test strip out the meter is turned off and the test result is stored automatically 27 Replacing Battery Veri Q Blood Glucose Meter uses a 3V Lithium Battery CR2032 This battery lasts for 1000 tests When the energy of battery is not enough the screen shows and blinks the battery mark It indicates that the energy left could operate testing about 50 times more At this time we suggest that you should replace the battery If you replace the battery while the meter is on the stored results will remain but the date time need to be reset Please turn the meter off before replacing the battery Open the battery lid 28 T
19. y a Please disinfect the instruments and parts for blood collection Do not reuse the test strips The used test strip and lancet should be handled carefully The Veri Q MGD 1001 Blood Glucose Monitoring System is for testing outside of the body in vitro diagnostic use I System Components I System Introduction Veri Q MGD 1001 Blood Glucose Monitoring System Veri Q MGD 1001 Meter a gt a M Button D Button Test Strip Slot Basic components provided Veri Q MGD 1001 Blood Glucose Meter Veri Q MGS 01 or MGS 01B Glucose Test Strips 10T Lancets 10 ea Lancing device Check Strip Pouch User manual Some kits do not include test strips and check strip Test strips and check strip are sold separately Components sold separately MGS 01 or MGS 01B Glucose Test Strips 25T 50T Veri Q Glucose Control Solution check strip Veri Q MGS 01 and MGS 01 B Glucose Test Strip STRIP tes Test Strip Vial MGS 01 B Test Strip MGS 01 Test Strip AX Use Veri Q MGS 01 or MGS 01B Test Strip with the Veri Q MGD 1001 Meter Please check the validity of test strips before using Please write the opening date of the new test strips vial in order to avoid using the expired products Display Eeg check a SOC It ahal LN eo m d mem 4 MEM Stored Test Result A Buzzer On Test Results ROY average Result ogi mg dL mmol
20. your healthcare program I Content Brief 1 Cautions 5 Safety Information 7 System Components 8 System Introduction Veri Q MGD 1001 Meter 9 Veri Q MGS 01 and MGS 01B Test Strip 10 Display 11 The Test Disinfectant Before Test 12 Insert Glucose Test Strips 13 The Method of Blood Collection 14 Add Blood Sample 15 Proper Blood Sample 16 Processing the Test Result 17 The Use of Function Buttons Checking Test Results Setting Mode Setting Complete Special Results Replacing Battery Cleaning Veri Q Blood Glucose Meter Troubleshooting Warranty Technical Specification Diagnostic System Important Information Symbols 19 21 26 26 28 30 31 35 36 37 39 42 I Test Principle Glucose in the blood sample reacts with glucose oxidase GOD on the test strip and a harmless DC Electrical current is produced This current is measured by the Veri Q Meter and displayed as your blood glucose result The strength of these currents changes with the amount of glucose in the blood sample The Veri Q Meter automatically interprets this reaction Test results with the Veri Q MGD 1001 meter are plasma equivalent The reference instrument used is the YSI 2300 glucose analyzer and is calibrated by YSI 2747 calibrator solution I Special Features Easy to check last 14 days average result Veri Q MGD 1001 Blood Glucose Monitoring System is designed fo