Home
DTDR1810 A & E
Contents
1. DIVISION 27 21 16 DECT DECR3000 SERIES FIBER OPTIC TRANSCEIVER ENGINEERING SPECIFICATIONS PART 1 GENERAL 1 01 SUMMARY A Fiber Optic 8 Channel Contact Mapping Ethernet Transmitter and Receiver 1 02 SECTION INCLUDES A DECT DECR3000 Series Contact Closure Transmitter and Receiver Standalone B DECT DECR3000 R3 Series Contact Closure Transmitter and Receiver Rack Mount 1 03 REFERENCES A Underwriters Laboratory UL B Underwriters Laboratory Canada ULC C European Union Compliance CE 1 04 SYSTEM DESCRIPTION A Performance Requirements Provide a Contact Closure Transmitter and Receiver system for the transmission of 8 channel contact mapping 1 The system shall utilize 1310nm optics capable of 8 channel contact mapping transmission on two multimode optical fibers DECT DECR3020 2 The system shall utilize 1300nm optics capable of 8 channel contact mapping transmission on two single mode optical fibers DECT3030 DECR3020 1 05 SUBMITTALS A Product Data Manufacturer s printed product data sheet for each type of Transmitter Receiver specified B Detail Drawings Electrical and optical connect drawings Product mounting template C Manufacturer s Installation and Operating Manual Printed installation and operating information for each type of Transmitter Receiver specified D Warranty Manufacturer s Printed Warranty 1 06 DELIVERY STORAGE AND HANDLING A Deliver materials in un
2. All optical fiber cables shall be properly installed and terminated with the mating optical connectors as submitted in article 2 07 A 4 The optical link shall be tested with either a power meter at a minimum or OTDR to ensure the link budget overall path loss Project name project number date Optional information e g owner A E plus an added 3dB of optical safety margin does not exceed the optical power budget as submitted in article 2 05 All optical connectors on cable shall be cleaned in compliance to optical connector manufactures specifications and covered with dust caps until connection to the fiber optic module Verify that the contact leads and optical fibers are properly connected Make sure that power is applied to all fiber optic modules controllers and receiver drivers or other equipment used in the system Successful contact mapping operation should be confirmed at this point by using 3 03 INSTALLATION the switches to toggle the contacts open and A General Locate fiber optic modules as indicated closed on the approved detail drawings and install 3 05 CLEANING module in compliance with the IFS installation A Follow all instructions for proper use of solvents and operations manual and adhesives used for termination and splicing 3 04 TESTING B Atcompletion of the installation dispose of all A Testing the Fiber Optic Contact Mapping Link fiber scraps properly Project name project number date
3. 00000 3 Section Title Optional information e g owner A E MANUFACTURED UNITS REFERENCE TABLES Table A Product Number Descriptions DECT3000 SERIES DESCRIPTION MAX DISTANCE DECT3020 MM 8 Channel Contact Mapping Transmitter 1300 1 2 Miles 2KM gt 2 Fiber DECT3020 R3 MM 8 Channel Contact Mapping Transmitter 1300 1 2 Miles 2KM gt 2 Fiber Rack Mount DECT3030 SM 8 Channel Contact Mapping Transmitter 1300 23 Miles 37KM gt 2 Fiber DECT3030 R3 SM 8 Channel Contact Mapping Transmitter 1300 23 Miles 37KM gt 2 Fiber Rack Mount Maximum distance is limited to optical loss of the fiber and any additional loss by connectors splices and patch panels DECR3000 SERIES DESCRIPTION DECR3020 MM 8 Channel Contact Mapping Receiver 1310 gt 2 Fiber DECR3020 R3 MM 8 Channel Contact Mapping Receiver 1310 gt 2 Fiber Rack Mount DECR3030 SM 8 Channel Contact Mapping Receiver 1300 gt 2 Fiber DECR3030 R3 SM 8 Channel Contact Mapping Receiver 1300 gt 2 Fiber Rack Mount Table B Product Compatibility Chart TRANSMITTER COMPATIBLE RECEIVER DECT3020 DECR3020 DECR3020 R3 DECT3020 R3 DECR3020 DECR3020 R3 DECT3030 DECR3020 DECR3020 R3 DECT3030 R3 DECR3020 DECR3020 R3 END OF SECTION Section Title 00000 4 Project name project number date Optional information e g owner A E
4. mber R3 EIA 19 card cage 2 09 MECHANICAL SPECIFICATIONS A Surface Mount Dimensions 7 1 x 4 9 x 2 0 18 00 cm x 12 45 cm x 5 08 cm B Rack Mount Dimensions 7 7 x 5 0 x 2 0 19 55 cm x 12 70 cm x 5 08 cm C Number of Rack Slots 2 D Finish Module shall be constructed of a metal enclosure with a powder coat finish model Number F63B12 with all connections and indicators silk screened directly on unit Rack mount units shall be constructed of anodized aluminum E Weight lt 2 0 lbs 1 0kg 2 10 ENVIRONMENTAL SPECIFICATIONS MTBF gt 100 000 Hours Operating Temp 40 C to 74 C Storage Temp 40 C to 85 C Relative Humidity 0 to 95 non condensing If product is installed under condensation conditions unit shall have conformal coating applied to the printed circuit board Add C to model number for conformal coated printed circuit board 2 11 REGULATORY AGENCIES APPROVALS AND LISTINGS SO OS Ol OY PURO Na comp Section Title 00000 2 A Underwriters Laboratory UL Listing Number I T E 6D16 B Underwriters Laboratory Canada ULC Listing Number I T E 6D16 C UL 94 flame rated PCB board 94VO D 2 12 ACCESSORIES A Card Cage IFS Model Number R3 EIA 19 card cage shall be available to house and power rack mount modules B Blank Panels IFS Model Number R3 BP shall be available to cover unused rack slots PART 3 EXECUTION 3 01 EXAMINATION A In
5. oduct Number Descriptions B Model Compatibility Chart Reference Table B Product Compatibility Chart 2 03 GENERAL SPECIFICATIONS A The 8 channel contact mapping system shall be an IFS DECT DECR3000 series module The module shall require no in field electrical or optical adjustments or in line attenuators to ease installation The module shall provide power and contact closed status indicating LED s for monitoring proper system operation The modules shall provide automatic re settable solid state current limiters and independent voltage regulators on each module to reduce the chance of a single point failure of the system The module shall be hot swappable in a rack mount system to reduce complete system shut down during maintenance or repair The module shall have an MTBF of gt 100 000 hours and operate in an environment of 40 C to 74 C and relative humidity between 0 to 95 non condensing The module shall be UL and ULC listed and CE marked The circuit board shall be UL 94 flame rated and meet all PCI standards All PC boards shall be designated with part number PC board number and show appropriate revision number Housing shall be of all metal construction All LED indicators and both electrical and mechanical connections shall be identified with silk screened labels The module shall have a lifetime warranty to reduce system life cycle cost in an event of a module failure 2 04 CONTACT SPECIFICATIONS A Contact Ra
6. opened factory packaging with Manufacturer s bar coding to the job site B Inspect product upon delivery to assure that specified products have been received C Store in original packaging in a climate controlled environment Storage Temperature not to exceed 40 C to 85 C 1 07 PROJECT SITE CONDITIONS A Temperature Requirements Products shall operate in an environment with an ambient temperature range of 40 C to 74 C without the assistance of fan forced cooling B Humidity Requirements Products shall operate in an environment with relative humidity of 0 to 95 non condensing If product is installed in condensation conditions unit shall have conformal coating applied to the printed circuit board Project name project number date Optional information e g owner A E 00000 1 1 08 WARRANTY A Standard International Fiber Systems Comprehensive Lifetime Warranty IFS warrants the product to be free of factory defects under manufacture s Lifetime Warranty as submitted under article 1 05 E PART 2 PRODUCTS 2 01 MANUFACTURER A Acceptable Manufacturer International Fiber Systems Inc 16 Commerce Road Newtown CT 06470 USA Telephone 203 426 1180 Fax 203 426 3326 Email sales ifs com Internet www ifs com B Substitutions Not Permitted C All fiber optic modules shall be supplied from a single manufacturer 2 02 MANUFACTURED UNITS A Model Number Descriptions Reference Table A Pr
7. spect modules before installation B Modules shall be free of any cosmetic defects or damage C All optical connectors shall be covered with dust caps and remain on the module until installing cable connectors to module D Shipping box shall include the module power supply and operations manual 3 02 PREPARATION A Standalone Module Surface Mount 1 Shall be mounted on a properly prepared surface adequate for the size and weight of module The placement of the unit shall allow provision for cable installation and maintenance as indicated on the approved detail drawings and in compliance with the IFS mounting template and installation manual B Rack Mount Module 19 Rack 1 Shall be installed in the IFS Model Number R3 card cage Ensure the card cage is installed in a standard EIA 19 482 6 mm rack or wall standoff bracket adequate for the size and weight of the card cage The placement of the unit shall allow provision for cable installation and maintenance as indicated on the approved detail drawings and in compliance with the IFS installation manual C Optical Fibers 1 Caution NEVER look into the end of an active optical fiber when using laser light output Eye damage can occur Wear eye protection when cleaving terminating and splicing fiber 2 The number and type multimode or single mode of optical fiber shall meet the requirements of the IFS model number in article 2 05 used in the installation 3
8. tings 100 VDC 0 5amps 10 watts B Normally open 2 05 OPTICAL SPECIFICATIONS A IFS Model Number DECT DECR3020 Optical Fiber 62 5 125 micron multimode Number of Fibers Required 2 Optical Wavelength 1310nm Optical Emitter Type 1310nm LED Transmitter Output Power 25uw 16 dB Se ee Section Title Optical Detector Type 1310nm PIN DIODE Receiver Sensitivity uw 30 dB Optical Power Budget 10 dB Optical Attenuation No manual adjustments required B IFS Model Number DECT3030 DECR3020 Optical Fiber 9 125 micron single mode Number of Fibers Required 2 Optical Wavelength 1300nm Optical Emitter Type 1300nm LED Transmitter Output Power 25uw 16 dB Optical Detector Type 1300nm PIN DIODE Receiver Sensitivity 1uw 30 dB Optical Power Budget 15dB Optical Attenuation No manual adjustments required 2 06 STATUS INDICATORS A Power On Red Off Off B Contact Closed Transmit Contact Closed Green Contact Open Off C Contact Closed Receive Contact Closed Yellow Contact Open Off 2 07 CONNECTORS A Optical SC B Power and Contacts Terminal Block with Screw Clamps 2 08 ELECTRICAL SPECIFICATIONS A Power 12 VDC B Current Protection Automatic re settable solid state current limiters C Voltage Regulation Solid state Independent on each board D Circuit Board UL 94 flame rated and meets all PCI standards E Rack mount Card Shall be hot swappable with IFS Model Nu
Download Pdf Manuals
Related Search
Related Contents
LOEWE Subwoofer Worldwide Lighting W83115C19-CH Instructions / Assembly MANUAL DO USUÁRIO ITS 車載器設計における留意事項 - JEITA 一般社団法人電子情報技術 Manual de usuario 0305-0306 VPL-ES3 Origin Storage Amacom Slimline Gas Flow Monitor CMG Series User`s Manual Copyright © All rights reserved.
Failed to retrieve file