K-BUS R KNX IP Interface User manual-Ver.1

image

Contents

1. Fig 3 3 parameter window IP address Parameter IP address The parameter defines the IP address of the IP Interface the IP address is unique on the LAN to avoid collide Option Byte x 0 255 The IP address should be entered in a byte by byte manner e g as follows for address 192 168 1 10 Bytel 192 Byte2 168 Byte3 1 Byte4 10 Parameter Subnet mask The parameter defines the subnet mask of the IP Interface The subnet mask must be set to reflect the number and structure of the subnet Option Byte x 0 255 In a small network the subnet mask 255 255 255 0 should be set as follows 9 SSS cmc EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com 255 Bytel Byte2 255 Byte3 255 Byte4 0 Parameter default gateway The parameter defines the default gateway The default gateway must be the same network segment with the IP address Option Byte x 0 255 The default gateway 192 168 1 1 should be set as follows Bytel 192 Byte2 168 Byte3 1 Byte4 1 10 EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com
2. indicate that telegram traffic is ongoing which is indicate by the LED 8 Auxiliary power supply connection 4 LAN connection Programming LED LED red light up for assignment of physical address LED green flashes for indicator of the device running normally Programming button 7 EIB KNX bus connection 3 Parameter setting description in the ETS 3 1 Parameter window IP settings Parameter window IP setting is shown in fig 3 2 Because IP Interface and RS485 converter use the same product database so before setting IP Interface parameters you must select devices first as follow fig 3 1 W i i1 3 IP Interface and E5485 Convertor Choose Choose devices IP settings IP address Choose Device IF Interface Ifo EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com EUROPOWER Qe EaI GR Fig 3 1 Choose device W 1 1 3 IP Interface and E5485 Convertor Choose devices IP settings IP settings IP address Pees pane roax 30 char If first char 4 or a VideoStar IP Convertor IP address assignment Don t use it if DHCP IF You use private protocol the port iz 1000 gt Fig 3 2 parameter window IP settings Parameter Device name Max 30 Char If first char A or a use DHCP The parameter defines the name of the IP Interfac
3. P mode is not used If the DHCP mode is used the parameter is invalid The fixed IP address can be assigned in the follow parameter window IP address see fig 3 3 Parameter If you use private protocol the port is The parameter is invalid for the IP interface The port number of IP interface is set to 3671 If you use private protocol the port number can be set via the parameter but the device will be used as a convertor instead of KNX IP Interface See also the product BTIC 01 00 1 When the device is used as a convertor its function is same with the BTIC 01 00 1 The parameter defines the port number of the convertor the port number of client devices must be same with the convertor or else their communications will fail 3 2 Parameter window IP address Parameter window IP address is shown in fig 3 3 Here set network connection information such as IP address Subnet mask and Default gateway If the IP Interface use DHCP mode the parameters are invalid in the window 8 ae EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com EUROPOWER Qe Ea KR W i ji 1 IP and E5485 Convertor Choose devices IP address IP settings IF address IF address Byte 1 Byte 2 Byte 3 Byte 4 Subnet mask Byte 1 Byte 2 Byte 3 Byte 4 Default gateway Byte 1 Byte 2 Byte 3 Byte 4
4. ROWER Sc em ce K BUS KNX IP Interface User manual Ver 1 BNIP 00 00 1 KNX EIB Intelligent Installation Systems SRP 00 a KIACT l LAN LIN E S T E EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com EUROPOWER e ea GR Contents 1 SUMMAaAry n anne nnn n nn nn nnn nn nn nnn nn nn nnn nn nn nnn nn nn nnn en nen en ence mene 3 2 Technical Properties amp Dimension and Circuit Diagram 3 2 1 Technical data 3 20 Dimension diagram 5 2 Circuit diagram 5 3 Parameter setting description in the ETS 6 3 1 Parameter window IP settings 6 0 Parameter window IP address 8 2 SSS SSS EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Li
5. dicator LAN LINK LED flashing Telegram traffic between the device and network EIB LINK LED ON KNX bus connection indicator EIB LINK LED flashing Telegram traffic between the device and KNX bus Temperature Operation 5 C 45 C Storage 25 C 55 C Transport 25 C 70 C Ambient Humidity lt 93 except condensation Design Modular installation device on 35mm mounting rail Dimensions 90 mmx36 mmx64mm Weight 0 1KG Housing colour Plastic housing grey Application program Max number of Max number of Max number of communication objects group address associations The KNX IP Interface 0 0 0 4 SE EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com EUROPOWER 2 2 Dimension diagram 36 0 mm BNIP 00 00 1 LAN LINK ACT EIB LINK ACT 90 0 mm 2 3 Circuit diagram E EIB LINK ACT d 5 Prog 6 gt 1 me e EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com SURPOWER z ea GR LAN LINK ON indicate that network connect normally LAN LINK flashing indicate that telegram traffic is ongoing Network activity is indicate by the LED 2 EIB LINK ON indicate that KNX bus connect normally EIB LINK flashing
6. e to identify the device on the LAN Here can entry a maximum of 30 characters in length The follow points apply for setting If the first character is A or a the device will work in DHCP mode and can get an IP address automatically from network And the character will not disappear in the device s name If the first character is F or f the IP address of the device need set by manual And the character will not disappear in the device s name For example If your device name is Family and you want to use DHCP mode Input string AFamily If you want to use Fix mode Input string F Family If your device name is Audio and you want to use DHCP mode Input string is AAudio If you want to use Fix mode Input string is FAudio If you input Audio then the device name is udio and use DHCP mode If your device name is start with another character you can input the device name directly with Fix IP address mode without with the F or T start If you want to use DHCP mode you only add A or a at ahead of your device name 7 SSeS a S E EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com Parameter IP address assignment Don t use it if DHCP The parameter indicates that the IP address assignment of the Interface is fixed if the DHC
7. se the Engineering Tool Software ETS ETS3 or later with a VD4 file to allocate the physical address and set the parameter The factory default physical addresses are 15 15 255 and the address can be modified directly via local interface settings of ETS The KNX IP Interface is a modular installation device It can be installed in the distribution board on 35mm mounting rails according to EN 60 715 This manual provides the technical information about the KNX IP Interface as well as assembly and programming in detail for users and explains how to use the interface device by the application examples 2 Technical Properties amp Dimension and Circuit Diagram 2 1 Technical data EUROPOWER ELECTRICAL LIMITED Unit 7 The Sandon Estate Sandon Way Liverpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com SURPOWER z on GR Power supply Operation voltage 21 30V DC via the EIB bus Current consumption EIB lt 12mA Power consumption EIB lt 360mW Auxiliary power supply 20 30V DC Auxiliary power consumption lt 2 5W Connections EIB KNX Via bus connection terminal black red External power supply Via bus connection terminal grey yellow LAN RJ45 socket for10 100Base T IEEE 802 3 network Auto Sensing Operating and Programming LED and button For assignment of the physical address display LED Green flashing The device running indicator LAN LINK LED ON Network connection in
8. verpool L5 9YN Tel 0151 207 5409 e mail europower europower electrical com www europower electrical com SURPOWER z ea GR 1 Summary The KNX IP Interface is designed for an intelligent building control system which is used for facilitating communication between the Ethernet network and the KNX system The KNX IP Interface connects the EIB KNX system with the Ethernet network via an Ethernet RJ45 interface in the front It serves as an interface between KNX installations and IP networks and can configure parameterize and commission the EIB KNX installation as well as bus monitor via the LAN using the ETS ETS3 or later software For operation an additional 30V DC supply is necessary The bus connection and auxiliary power supply connection are carried out via using EIB bus connection terminals The device adopts an Ethernet RJ45 interface to connect with LAN network The network interface can be operated with a transmission speed of 10 100Mbit s Auto Sensing The IP address of the device can be fixed or can be received from a DHCP server If you need to remain the IP address static or here no DHCP server on the network you can assign a fixed IP address to the device via ETS The application program is preloaded in the factory the IP address ts fixed and the port number ts set to 3671 Note the device cannot program itself but need via other communication interface device to program it The KNX IP Interface is able to u