1. MNCROF PROFESSIONAL PRODUCTS WWwwemicronpro com Cope D F ee we E amp ee E USER MANUAL LEDPROG4AGEW Keep this manual for future reference TABLE OF CONTENTS 1 INTRODUCTION AND UNPACKING 1 2 SAFTEY INSTRUCTIONS 1 2 3 OPERATION INSTRUCTIONS 2 3 4 MOUNTING AND INSTALLATION 4 5 DMX 512 CONTROL CONNECTIONS 6 PHOTOMETRIC DATA 5 6 7 DMX CHANNELS 6 8 KEY FEATURES 7 9 TECHNICAL SPECIFICATIONS 7 8 10 MAINTENANCE AND CLEANING 1 INTRODUCTION AND UNPACKING Thank you for purchasing the MICROH LEDPRO64RGBW wash fixture For your own safety and knowledge please read this manual before installing or operating the device This manual covers the important information on installation and applications Please install and operate the fixture according to instructions Meanwhile please keep this manual for future reference The MICROH LEDPRO64RGBW wash fixture is made of a new type of high temperature cast aluminum casing The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol This fixture is applicable but not limited to large scale live performances theater studio nightclubs and discos The MICROH LEDPRO64RGBW wash fixture uses 36 powerful 3W 9 Red 9 Green 9 Blue 9 White LED s which feature high brightness and stability Please carefully unpack it when you receive the fixture and check if it
2. TECHNICAL SPECIFICATIONS MODEL LEDPRO64RGBW LAMP 36 x 3W LEDs 9 Red 9 Green 9 Blue 9 White OPERATING TEMPERATURE 25 C to 45 C VOLTAGE 120VAC 60Hz 1 1A 132W FUSE 120VAC 2A DIMENSIONS 12 x 11 x 9 305 x 279 x 229 mm PACKING DIMENSIONS 16 x 12 6 x 10 75 406 x 320 x 273 mm NET WEIGHT 11 5 Ibs 5 22 kg GROSS WEIGHT 13 1 Ibs 5 94 kg WARRANTY 2 Year Limited Warranty 10 MAINTENANCE AND CLEANING The following points have to be considered during the inspection 1 All screws for installing the device or parts of the device must be tightly connected and must not be corroded 2 There must not be any deformations on the housing colour lenses fixations or installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage must be handled by a skilled installer or technician Any safety issues must be resolved CAUTION DISCONNECT POWER BEFORE SERVICING In order to keep the fixture in good condition and extend the life we suggest regular cleaning to the fixture 1 Clean the inside and outside lens each week to avoid the light output from darkening due to accumulation of dust dirt etc 2 Clean the fan each week 3 A detailed electrical check by approve
3. appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture Whether installing inverted on a truss or ceiling or set on a flat level surface see illustration below Be sure this fixture is kept at least 0 5m 1 5 ft away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Mounting Points Overhead mounting requires extensive experience including calculating working load limits A knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture are all imperative and should only be performed by a qualified technician Improper installation can result in bodily injury and damage Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Floor Mounting Set the 2 brackets at your desired angle and aim your fixture accordingly Please see diagram below Clamp Mounting The MICROH LEDPRO64RGBW provides a unique mounting bracket assembly that integrates 2 brackets to be used to mount on a truss or the floor When mounting this fixture to truss be sure to secure an appropriately rated clamp to the included bracket fitted through the center hole As an added safety measure be sure to attach at least one properly rated safety c
4. is not in use or before cleaning it Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective It should decrease gradually Please do not project the beam onto combustible substances Fixtures cannot be installed on or near combustible substances Keep more than 50cm distance from wall for proper ventilation and air flow If your fixture is or has become damaged in any way it shall be exclusively replaced or repaired by the manufacturer to avoid any hazard CAUTION Never touch the device during operation The housing may heat up CAUTION Never look directly into the light source as sensitive persons may suffer an epileptic shock CAUTION The electric connection must only be carried out by a qualified electrician 3 OPERATION INSTRUCTIONS Do not turn on the fixture if it has been through severe temperature differences Damage may occur to the fixture Wait until unit is at room temperature to operate The unit should be protected from any tremor or agitation during transport Do not expose the fixture in any excessive heat moisture or any environment with too much dust when installing Do not lay any power cables on the floor It may cause electronic shock or damage to persons or equipment Make sure to attach the safety chain and ensure the screws are properly screwed in when in
5. able to the fixture Regardless of the rigging option you choose for your MICROH LEDPRO64RGBW wash fixture always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle 5 DMX 512 CONTROL CONNECTIONS This fixture complies with international USITT DMX standards and can be used with either a 3 pin or 5 pin DMX connector Plug in the provided 3 pin XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the LEDPRO64RGBW To connect the units to DMX you must daisy chain the fixtures together as referred in the diagram below Always end your DMX 512 connection with a DMX terminator DMX OUTPUT CONTROLLER FIXTURE 1 FIXTURE 2 FIXTURE 3 X X X X X K UPTO 30 UNITSIN MASTER SLAVE MODE S SS SS SS Y x Fe vt vt Pi Fe XLR CABLE XLR CABLE XLR CABLE DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket COMMON pea DMX512 OUT DMX512 IN 3 Data SPIN XLR DMX 3 PIN XLR For installations where the DMX cable has to run a long distance or is in an electrically noisy environment it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is
6. d technician every three months is advised Ensure the circuit contacts are in good condition and prevent from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the instructions under Installation instructions Should you need any spare parts please order genuine MICROH parts from your local dealer IF YOU SHOULD EXPERIENCE ANY PROBLEMS OR ISSUES PLEASE CONTACT MICROH PROFESSIONAL PRODUCTS BY EMAIL AT info microhpro com In the event that your unit is defective in any way please contact your local dealer to obtain an RA number for service repair DISCLAIMER MICROH believes that the information contained within this user manual is accurate However Microh is not responsible for any error or addendums to this manual If you have any comments or general suggestions on how this manual can be improved please contact info microhpro com Thank you PROFESSIONAL PRODUCTS www microhpro com
7. simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 1209 gt y i PIN3 PIN 2 6 PHOTOMETRIC DATA MICRO LEDPG6G4RGBW PROFESSIONAL PRODUCTS Photometric Data R 6440 2400 530 _ 228 125 _ 80 lux G 13080 6730 1240 550 330 187 lux B 10980 4950 1210 __ 536 _ 290 _ 124 lux W 11110 3960 966 412 225 _ 154 lux RGBW 32100 15130 4040 1630 830 580 lux U N a oa N Ww 05 1 2e _ 3 4 5 Distance Meters 0 375 0 75 15 225 OO 30 3 75 Diameter Meters 7 DMX CHANNELS CH NO VALUE FUNCTION 000 189 Brightness Adjust dim bright 190 250 Strobe slow fast 000 255 Red dim bright 000 255 Green dim bright 000 255 Blue dim bright CH1 CH2 CH3 CH4 H5 000 255 Cool white dim bright 8 KEY FEATURES 36 x 3W LEDs 9 Red 9 Green 9 Blue 9 White 9 Operation Modes 3 Pin XLR Input amp Output DMX Control Double Bracket for Truss and Floor Mounting Built in microphone 3 Button LED Digital Display MODE UP DOWN 9
8. ss MODE button select J xx Press UP or DOWN to select the colour change speed from 1 99 From slow to quick 4 COLOUR FADE Press MODE button select F xx Press UP or DOWN to select the colour fade speed from 1 99 From slow to quick 15 COLOUR FADE Press MODE button select F xx Press UP or DOWN to select the colour fade speed from 1 99 From slow to quick AUTO Press MODE button select A The 15 colour change program and 15 colour fade program run alternatively UP or DOWN buttons do not function in this mode SOUND ACTIVE Press MODE button select S xx Press UP or DOWN to select sound active sensitivity grade 0 31 0 is off 1 is the lowest sensitivity 31 is the highest sensitivity SLAVE Press MODE button select S L A UP or DOWN buttons do not function in this mode DMX Press MODE button select slave mode DMX address xxx Press UP or DOWN to select DMX address You can set 512pcs address from 001 to 512 It will flicker when there is no controller signal 4 MOUNTING AND INSTALLATION Caution For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixture to any surface make sure that the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an
9. stalling the fixture Make sure the lens is in good condition It is recommended to replace the unit if there are any damages or severe scratches Make sure the fixture is operated and installed by qualified personnel Keep the original packaging in case of defective product Any non manufacturer additions modifications or changes in any way will void all warranty Please do not attempt to open unit It is only to be serviced by an authorized technician If this occurs or is apparent the warranty will be voided The fixture s warranty will be voided if there are any malfunctions from not following the user manual or any illegal operation shock short circuit electronic shock lamp broke etc This unit has a total of 9 operating modes Static Colour Select 4 Colour Change 15 Colour Change 4 Colour Fade 15 Colour Fade Auto Sound Active Slave amp DMX To initialize extra factory setting press MODE amp UP buttons at the same time while program is on Auto mode To keep the display on at all times press MODE amp UP buttons simultaneously To have the display turn off after 20 seconds press MODE amp DOWN buttons simultaneously STATIC COLOUR SELECT MODE Press MODE button select C xx Press UP or DOWN to select static colours 0 15 4 COLOUR CHANGE Press MODE button select J xx Press UP or DOWN to select the colour changing speed from 1 99 From slow to quick 15 COLOUR CHANGE Pre
10. was damaged during the transportation And please check whether the following items are included inside the box Fixture One User Manual One 2 SAFTEY INSTRUCTIONS CAUTION ELECTRIC SHOCK WARNING USE EXTREME CAUTION WHEN HANDLING WIRES This device has left the factory in perfect condition In order to maintain this condition and to ensure safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual ZT Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature and is dry This device falls under protection class therefore it is essential that the device be grounded The electrical connection must be carried out by a qualified technician The device should only be used with rate voltage and frequency Make sure that the available voltage is not higher than 120V as stated at the end of this manual Make sure the power cord is never crimped or damaged in any way as this could cause shock and damage If your power chord is damaged in any way please purchase a new cable from your local MICROH dealer Always disconnect power when the device