Home

david pal36

image

Contents

1. K 10 1 Power Switch OFF PWR LIB1 LIB2 Set to PWR to turn the PAL36 on and to select Library 1 LIB1 sessions or Library 2 LIB2 sessions 2 Library 2 Light LIB2 Indicates that sessions in Library 2 have been selected 3 Power Light PWR Indicates that the PAL36 is on or in standby 4 9 Volt Adapter Jack Insert adapter plug into adapter jack use a 9 volt adapter with 1 3 mm plug and centre positive 5 Session Number Lights 1 6 Indicates the session number They are also used to display the battery power intensity and volume levels 6 ABC Indicator Lights Indicates the session number 7 VOL Button Volume Note button raised to guide you in locating with eyes closed during sessions Use to increase or decrease the volume of the tones Also used to clear most recent played sessions Page 7 8 INT Button Intensity Note button raised to guide you in locating button with eyes closed during session Use to increase decrease intensity of the lights in the eyeset 9 SEL Button Select Use to select session while sessions are scanning During a session use to select tone Pulsed Tone Binaural Beats Chime or to turn all tones off Also use to turn heartbeat sound on or off 10 OMNISCREEN Jack Insert Omniscreen eyeset plug into OMNISCREEN jack Use the patch cord with the small 2 5 mm plug 11 HEADPHONE Jack Insert headphone plug into HEADPHONE jac
2. the indicator lights will scroll from 6 to 1 to confirm that Soft Off is in progress Soft Off will take 2 minutes to complete Battery Power Level As soon as the PAL36 is turned on the battery power level will show on the lights from 1 to 6 If the power level is 1 then the battery is too low to operate the PAL36 and it will automatically go into standby If the power level is 2 or less the battery may not have enough power for the entire session If the battery power gets too low during a session the session will end early with Soft Off The number indicator lights will scroll from 6 through 1 to indicate that Soft Off has begun and the power indicator light will flash Replace the battery or use an adapter if battery power level is at 2 If you have the PAL36 plugged into a 9 volt adapter the power level will always show a power level of 6 Selecting a Session The PAL 36 has 30 preset sessions They are organized in two libraries LIB1 and LIB2 Refer to page 13 to select a preset session As soon as the PAL36 is turned on the last three sessions selected displayed including whether they were from LIB1 or LIB2 Then the PAL36 will start to scroll through each of the preset session numbers starting with bank A A1 A2 A3 etc After the A sessions the PAL36 will scroll through the B sessions and then the C sessions When the desired session lights up Page 9 press SEL If you prefer a sessi
3. Schumann Resonance For 40 min 7 8 effective deep meditation and to improve the onset of sleep Calms hyper chattery minds Also for chronic fatigue fibromyalgia and anxiety Ideal for those with insomnia who have a busy mind and tense body B5 State Five Meditation Use for 33 min 7 ultra deep meditation and for sleep Use to quiet hyper minds Based on Maxwell Cade s work with Zen meditators Theta The Dream State Enhance Your Creativity Use theta with guided imagery music or for learning new behaviours and habits B6 Theta Hemi Step Use for creative 36min 5 5 visualization and sleep Delta The Sleep State These sessions help bring on sleep by turning off the chatter that sometimes occurs after a busy day C1 Meditate to Sleep Meditate visualize 45min 8to3 and think soothing thoughts during the first half 8 Hz fall asleep during the second half 3 Hz Page 14 Session Session Target Number Description Time __Rate Hz Library 1 Sessions LIB1 1 18 C2 Delta To aid in falling asleep Best for 45 min 3 5 those with pain Fall asleep with session running C3 Sub Delta Calms the hypothalamus 24min 0 5 1 Beneficial for some with fibromyalgia and hypertension Depression Reduction C4 Alpha Beta Settles down negative 30 min L10 R18 emotions from the right brain while stimulating the left brain to rebalance alpha asymmetry C5 Alpha Relaxer This session
4. as desired Press and hold SEL and INT The indicator lights 1 to 6 will scroll from 1 to 6 and back to 1 Your new preferences will be saved only when the session ends until all lights and tones are completely off You may use Soft Off press and hold INT and VOL to end the session sooner 2 minutes Playing Pre Recorded Material To play pre recorded material into the headphones plug one end of the patch cord provided into the headphone jack of the CD MP3 computer or cassette tape player and plug the other end into the AUDIO IN jack of the DAVID PAL36 If the playing time of the audio material is longer than the session selected the session will end but the audio material will continue to play and be heard through the headphones Playing Sound Sync LIB2 B3 B6 Using the patch cord provided connect your CD MP3 computer or tape player to the DAVID PAL36 follow instructions above Select Sound Sync session With the Omniscreen eyeset on increase the volume on the audio material until you notice the lights dance If the volume is too low or stops for 10 seconds the session will begin to Soft Off the number display will scroll 6 through 1 to indicate Soft Off has begun When the volume is turned up or the sound returns the lights will gradually brighten Soft On and dance again The numeric display will scroll 1 through 6 to indicate Soft On has begun Battery Replacement and Power Management The DAVID PAL36 ca
5. of Liability oeei aeia 4 Whe DAV ID Experience cesor ine aee ee ee eaaet ine 5 Heart Rate Variability sccretari atiii 6 DAVID PAL36 Diagram i e ee E N E iia 7 Operating Instructions 00 0 0 eee eeceeeeseeeeeeeeseeeseeseecaecsaecnseenseeees 9 Care and Maintenance for the DAVID PAL36 uu eee 12 Description of Preset SeSSIONS ceeeesecesecsseceeeceseeeseeeseeeeneeeaes 13 Before You Call for Repairs eecesecssecsseceseceseceseceseeeseeseneeenes 17 Page 19 DAVID PAL36 MIND ALIVE CANADA ON DAVID Pal 36 ie came Operator s Manual Page 20
6. AL36 require repairs you must contact our service department at 1 800 661 MIND Canada and U S only or 780 465 6463 to obtain a warranty repair authorization number and important shipping instructions When returning your DAVID PAL36 be sure to surround the DAVID PAL36 with at least one inch of tight packing on all sides in a strong carton Neither Mind Alive Inc nor courier companies will pay for damage incurred by poorly packaged goods Label the carton FRAGILE HANDLE WITH CARE Include a copy of your sales receipt and a brief written description of the problem All postage insurance and shipping costs incurred in returning the DAVID PAL36 for service are the responsibility of the customer Page 3 FOR UNITED STATES AND INTERNATIONAL CUSTOMERS Failure to receive proper instructions about completing customs and shipping documents may result in additional brokerage and duties charges to the customer Some courier companies do not include brokerage fees in their quoted charges The customer is responsible for any and all charges Equipment will not be returned to the customer until these charges have been paid Indicate on ALL shipping documents RETURN TO COUNTRY OF ORIGIN FOR REPAIRS UNDER WARRANTY DISCLAIMER OF LIABILITY Mind Alive Inc its employees its authorized dealers and distributors shall not be held liable for any claim demand action cause of action liability or damages arising out of any injuries resultin
7. INTRODUCTION You have purchased the most innovative high quality audio visual entrainment device available on the market today The DAVID PAL36 combines the necessary principles of audio visual stimulation and cranial electrical stimulation to safely and effectively guide the user into desired states of consciousness and maximum brain functioning We are confident you will find using the DAVID PAL36 not only an enjoyable relaxing experience but also beneficial as you explore heightened states of consciousness and personal awareness The DAVID PAL36 is non invasive and no electrical current is passed through to the user All resulting effects are produced in the brain solely by audio visual stimuli The portability of the DAVID PAL36 lends itself to easy travel airport X ray machines will not harm the DAVID PAL36 In order to obtain maximum enjoyment and benefits from your DAVID PAL36 please read this operator s manual thoroughly COMPONENT LIST 1 DAVID PAL36 Serial Number 2 Tru Vu Omniscreen Eyeset U S Patent 5 709 645 3 Headphones 4 Stereo Patch Cord 5 Carry Bag 6 9 Volt Alkaline Battery 7 DAVID PAL36 Operator s Manual 8 Warranty Card OPTIONAL ACCESSORIES FOR DAVID PAL36 1 9 Volt Adapter 2 DAVID Session Editor 3 Two User Package includes eyeset headphones splitter cords 4 View Hole Omniscreen Eyesets If you have any questions require assistance or wish to receive information
8. VID PAL36 should be done with a soft cloth slightly moistened with water or with a mild detergent Do not clean with any solvents Although precautions have been taken to protect the PAL36 from static electricity do not subject the PAL36 to static such as placing it near a television set or static producing fabrics and materials Do not place the PAL36 near heat sources such as radiators or air ducts or in direct sunlight or expose to excessive dust or mechanical vibration Should any liquid enter the PAL36 turn it off immediately Although the PAL36 is water resistant it is not waterproof If liquid does enter the electronics we advise that the PAL36 be checked by authorized personnel before commencing operation Page 12 DESCRIPTION OF PRESET SESSIONS Note All Preset Sessions include Heart Rate Variability throughout the session and Dissociation at the beginning of each session For Dual Brainwave Stimulation Sessions eg Session C4 L10 R19 the L and R for the target rate represent the visual field of stimulation Left visual field stimulation means right brain hemisphere stimulation right visual field stimulation means left brain hemisphere stimulation Session Session Target Number Description Time __ Rate Hz Library 1 Sessions LIB1 1 18 SMR and Beta Let s Get Alert Al Sensory Motor Rhythm SMR Use 24 min 14 to achieve relaxed attention A2 SMR for Sleep Use to improve sleep 40 min 14 fo
9. e All of the DAVID PAL36 sessions except Sound Sync Sessions begin with the pulsed tone on Press the SEL button once to turn the pulsed tone off and select Binaural Beats Press the SEL button again to turn Binaural Beats off and select Chime Press SEL once more to turn all tones off Press SEL again to turn the pulse tones back on Adjusting Volume Note The volume button VOL is raised to guide you to locate button with eyes closed during sessions To increase the volume of the tones through the headphones press and hold the VOL button To decrease the volume release VOL button and press and hold again Or you may press short single steps for small adjustments in the volume The indicator lights 1 to 6 will show the volume level Adjusting Intensity Note The intensity button INT is raised to guide you in locating button with eyes closed during sessions To increase the intensity of the lights in the Omniscreen eyeset press and hold the INT button To decrease the Page 10 intensity release the INT button and press and hold again Or you may press short single steps for small adjustments in the intensity The indicator lights 1 to 6 will show the intensity level To Save Intensity Volume Tone and Heartbeat Settings Specific preferences settings of intensity volume tone and heartbeat on or off can be saved for each session To save preferences while the session is running adjust intensity volume tone and heartbeat
10. g from malfunction or defect of the said DAVID PAL36 whether wilful or negligent either to person or damage to property of the purchaser employees of the purchaser persons designated by the purchaser for training in the use of the DAVID PAL36 clients or patients of the purchaser any other person designated by the purchaser for any purpose prior to or subsequent to acceptance delivery installation and use of the DAVID PAL36 either at the premises of Mind Alive Inc or the premises of its dealers or distributors or the purchaser s premises The purchaser employees of the purchaser clients or patients of the purchaser or any other person designated by the purchaser for any purpose hereby undertake to waive and disclaim any action in respect of the aforesaid terms as above Page 4 THE DAVID EXPERIENCE Welcome to the experience of the DAVID PAL36 a digital audio visual entrainment AVE device designed to support you in your quest for wellness by promoting various areas of the brain to work together in a harmonious fashion Through the use of AVE you may experience yourself in a new and beneficial way Many users of the DAVID PAL36 experience e deep relaxation while feeling more energized visual images colors and patterns e the sense of feeling grounded and calm e increased mental clarity for resolving problems e enhanced interpersonal relationships How and why do these sensations occur Several changes take place du
11. has 30 min 10 to an alpha frontend to reduce anxiety L10 R18 and enhance relaxation Hypnosis C6 Fractionated Hypnosis Alpha This 30 min 8 session simulates the hypno therapy process Library 2 Sessions LIB2 19 30 Relaxation and Sleep A1 Wise Guy Alpha It has been shown 30 min 10 6 that people with fast running alpha waves have higher than average IQs A2 Coffee Break Alpha Great for a little 15 min 10 rest during your coffee or lunch break A3 Paradise A gentle slide down to Theta II 36 min 6 5 Extraverts with low anxiety produce high levels of this frequency A4 Sleep Alpha to Theta This session 36min L10 R6 can really help to break up distressing thoughts that are interfering with sleep Page 15 Session Session Target Number Description Time Rate Hz Library 2 Sessions LIB2 19 30 Stimulating Sessions AS SMR Beta Like the Brain Brightener 24min L13 5 R18 but more gentle and more entraining A6 Mental Flexibility To loosen up a 22 min 4 to 20 stuck mind Can also be used for fibromyalgia B1 Artistic Development and Creativity 30 min L18 RO 2 This session stimulates the right brain only Helps left brained analytical people feel more spontaneous and creative B2 Roller Coaster This action packed 7 min session is very engaging Some with ADD can benefit Lucid Dreaming Sound Sync Based on audio input Travel on lucid journeys with yo
12. k 12 AUDIO IN Jack Use to listen to music during a session Also use to download or erase a session with the DAVID Session Editor Plug one end of the patch cord with the larger 3 5 mm plug into the headphone output of your CD player computer or MP3 player and the other end into the AUDIO IN jack of the PAL36 Figure 2 Back 9 Volt Alkaline Battery Battery Compartment Install 9 volt battery into battery compartment as shown Page 8 OPERATING INSTRUCTIONS For best results we recommend that you drink a glass of water 15 minutes before a session Ensure that your environment is conducive to relaxation For example be sure that you will not be interrupted you are wearing comfortable clothing there is no excessive noise and the room is set at a comfortable temperature You should be sitting down in a reclined position or lying down Although you may keep your eyes open or closed most people enjoy the sessions with their eyes closed Turning DAVID PAL36 On and Off To turn the PAL36 on slide the switch to the PWR either LIB1 or LIB2 position To select a session from Library sessions set switch to LIB1 To select a session from Library 2 sessions set switch to LIB2 To turn the PAL36 off slide the switch to the OFF position The green PWR light will remain dimly lit reminding you to turn the PAL36 off To End a Session Early Using Soft Off Press and hold the INT and VOL buttons When you select Soft Off
13. ll connections to audio player Adjust volume to moderate listening level Re adjust settings and re set preferences WARNING ALL persons who a have a history of epilepsy photic epilepsy or any seizure disorder b suffer from any mental disorder illness c are currently using ANY drugs prescription or recreational d are under the influence of alcohol SHOULD NOT USE the DAVID PAL36 unless under the supervision of or consultation with a medical doctor THE DAVID PAL36 IS NOT RECOGNIZED AS A TREATMENT OR CURE OF ANY MEDICAL CONDITION OR DISABILITY HOWEVER RESEARCH SUGGESTS THAT THE DAVID PAL36 IS AN EFFECTIVE RELAXATION AND MEDITATION TOOL The DAVID PAL36 is a non invasive tool All resulting effects are produced in the brain solely by audio and visual stimulation All rights reserved Reproduction in whole or in part is forbidden without the express written consent of Mind Alive Inc Tru Vu Omniscreen Eyesets protected under U S Patent 5 709 645 Mind Alive Inc 2003 2005 2006 Mind Alive Inc Edmonton Alberta Canada Page 18 TABLE OF CONTENTS WntrodUctiOn 2 02260 see dvs ctee tive eevee E ene ee 1 Component Lister aee r er eine 1 Optional Accessones 0 cuceceveedeeeecceteeceeaue cae yeeee esac v ii 1 Weal S54 2 ce soe Daca lls E a eb cokes Mosul a ta Sette rote cults doce Besa tebace se 2 Precautions ninap Siti rne naea Pie ee Res Ra Gee 2 Warranty seis si a E AE E E N E aie E ed 3 Disclaimer
14. n be powered using a 9 volt battery or a 9 volt positive centre 1 3 mm plug AC adapter To replace the battery slide battery compartment cover off Slide the bottom of the battery into the battery compartment under the edge push the battery down into place to connect the poles If the PAL36 is plugged into an adapter no power will be used from the battery The PAL36 will remain in standby at the end of a session and use minimal battery power Turn the PAL36 off at the end of the session to preserve your battery An alkaline 9 volt battery will provide approximately seven hours of operation Page 11 To Record or Clear Session History Each time you play a preset session the session number will be stored in the PAL36 so that you can have faster access to the last three sessions selected To clear these sessions press VOL while the PAL36 is scrolling for a session to be selected This will erase or clear the session history Downloading Erasing a Session Your DAVID PAL36 is programmable There are six blank sessions C1 to C6 in Library 2 for storing additional sessions All of the preset sessions may be reprogrammed or erased To add or change sessions you will need the DAVID Session Editor The PAL36 may also be programmed automatically from an encoded CD eg Special Application Sessions Refer to the DAVID Session Editor help file for design and download instructions CARE AND MAINTENANCE FOR THE DAVID PAL36 Cleaning of the DA
15. ompensate activity settle down dramatically using controlled slowed deep breathing techniques The heart speeds up with every breath in and slows down with every breath out This difference in heart rate is called Heart Rate Variability HRV For example a relaxed person using controlled breathing may have a heart beat of 80 beats per minute while breathing in and as low as 65 beats per minute while breathing out The difference or swing is about 15 beats per minute bpm When people get stressed their heart typically clamps as low as 5 bpm HRV and spikes sometimes as high as 30 bpm HRV This is abnormal activity and is rough on the heart The HRV technique used in the DAVID PAL36 is based on a 10 second breathing cycle six breaths minute by inhaling slowly for 5 seconds and exhaling slowly for 5 seconds in an easy relaxed breath When using HRV paced breathing listen to the heartbeat generated by the PAL36 through the headphones Inhale for two heartbeats and exhale for two heartbeats not your own heartbeats All PAL36 sessions begin at seven breathing cycles minute 28 heartbeats min and slow to six breaths minute 24 heartbeats min This allows the user to breathe a little faster at the onset of a session until he she has had time to relax Page 6 DAVID PAL36 DIAGRAMS Figure 1 Front Panel MIND ALIVE 1m DAVID Pal 36 Ly ja SJ 2 LIB2 ie 7 1 at U AUDIO IN HEADPHONE OMNISCREEN 9
16. on from group B or C wait for the A group to finish and the B group will scan followed by group C Pressing the INT button will allow you to scan through the sessions faster If LIB2 sessions are being selected the LIB light will be on Once a session has been selected the session number will flash a few times then scroll from 1 through 6 to indicate Soft On The eyeset lights and headphone volume will start low and gradually increase over ten seconds until the levels reach the preset settings of intensity and volume Soft On This allows you time to put on the eyesets and headphones During the remainder of the session the session light eg Al B4 will flash briefly every few seconds to remind you of the session number selected Every eighth flash will show the battery power level 1 to 6 As the session ends the eyeset lights and volume will fade out Soft Off The number display will scroll 6 through 1 to indicate Soft Off If no buttons are pressed the PAL36 will go into standby in two minutes The green PWR light will remain dimly lit reminding you to turn the PAL36 off Selecting Heartbeat All of the DAVID PAL36 sessions except Sound Sync Sessions begin with the heartbeat on To turn to heartbeat off press and hold the SEL button for approximately one second To turn the heartbeat back on press and hold the SEL button again for approximately one second Selecting Pulsed Tone Binaural Beats Chim
17. on new product developments and research currently being conducted at Mind Alive Inc visit our website at www mindalive com or call toll free at 1 800 661 MIND 6463 Outside Canada and the U S call 780 465 6463 Page 1 WARNING If you are an epileptic or photic epileptic We recommend that people with a history of epilepsy and or photic epilepsy not use the DAVID PAL36 unless under the supervision of a medical doctor If you are taking drugs or using alcohol We recommend that people currently using drugs prescription or recreational and or excessive alcohol consumption consult with their doctor before using the DAVID PAL36 If you are a first time DAVID PAL36 user We advise that you always remain seated or reclined while using the DAVID PAL36 We also suggest that new users always begin sessions with low intensity brightness in the eyesets If at any time during a session you begin to feel vertigo nausea or a sense of mental instability lower the intensity of the eyesets and lower the volume of the tones or discontinue the session PRECAUTIONS Traumatic Childhood Experiences The DAVID PAL36 can cause the release of suppressed memories If traumatic memories surface during or after a session be certain to seek appropriate support Somnatic Shock If abruptly returning to a normal conscious state a mild case of somnatic shock can result leaving the user feeling disoriented nauseous or experiencing a headache All pre
18. r those with insomnia due to a racing mind but relaxed body A3 Beta Perker A great way to get going 20 min 18 to 20 in the morning without caffeine This session helps reduce ADD and SAD symptoms May cause anxiety A4 ADD and Learning This session has 26 min L14 R18 amp 10 rapid transitions for mental stimulation to help keep the user engaged in the session Used in the ADD study published in the Journal of Neurotherapy A5 Brain Brightener Use with seniors to 30 min L14 R18 amp 10 improve mental functioning and memory Similar to A4 but uses gentle transitions Can also be used for ADD A6 Skill Sport Enhancement Use this 24min 7 8to 18 session to develop any skill or improve performance Visualize feeling your best during the first half alpha Then visualize your perfect performance during the second half beta of the session Page 13 Session Session Target Number Description Time Rate Hz Library 1 Sessions LIB1 1 18 Alpha Great for Relaxation and Meditation B1 Healthy Alpha Relaxer Healthy alpha 30 min 10 is 10 Hz Most disorders have alpha slowing This session re establishes the natural alpha rhythm Good for beginners B2 Extended Deep Alpha Relaxer Stay 80 min 8 4 relaxed for your dental massage physiotherapy chiropractic and other appointments B3 Schumann Resonance For a quick 22 min 7 8 thorough afternoon meditation For those on the go B4 Extended
19. ring and following an AVE session The first aspect of AVE involves dissociation Dissociating is the first step towards effective clearing of the mind and meditation This clearing of thoughts and loss of body awareness is similar to what a Zen mediator would experience Secondly cerebral blood flow increases Most cognitive and emotional disorders involve areas of the brain that are low in blood flow A study by Fox and Reichle showed AVE increased cerebral blood flow up to 28 Thirdly EEG activity changes The concept of entrainment is about altering brainwave activity Quantitative EEG QEEG studies have confirmed the normalization of brain activity following an AVE session Aberrant brainwave activity in various conditions such as depression anxiety ADD seasonal affective disorder chronic fatigue etc may be restructured into healthier patterns Recommended Reading e Change Your Brain Change Your Life Daniel Amen e The Rediscovery of Audio Visual Entrainment Technology Dave Siever e Getting Started with Neurofeedback John Demos e The AVE Session amp Protocol Guide for Professionals Dave Siever Page 5 HEART RATE VARIABILITY HRV Long graceful breathing cycles have long been used as part of meditation Scientifically this technique has been analysed and shown to settle down a stressed autonomic nervous system Both sympathetic flight or fight activity and para sympathetic the brain s efforts to c
20. set sessions in the DAVID PAL36 are programmed to end with the lights fading out Soft off to avoid somnatic shock Orthostatic Hypotension Occasionally when a person becomes very relaxed during a session his her blood pressure may fall significantly We advise rising slowly after a session Refer to The Rediscovery of Audio Visual Entrainment Technology available from Mind Alive Inc for more detailed information Page 2 WARRANTY The DAVID PAL36 is warranted against defects in workmanship or materials for one year from date of original purchase on the terms stated herein Should this unit become inoperative within the one year period it will be repaired or replaced at our option without charge Any postage insurance and shipping costs incurred in returning the DAVID PAL36 for service are the responsibility of the customer To activate your warranty return the enclosed warranty card to Mind Alive Inc 9008 51 Avenue Edmonton Alberta Canada T6E 5X4 or you can register online at www mindalive com registration htm This warranty does NOT cover e shipping damage e damage caused by re charging batteries e damage caused by accidents or by other than normal use e improper battery installation and or charging e cords for headphones and Omniscreen eyeset e damage caused by exposure to excessive static electricity e damage caused by any unauthorized person opening the DAVID PAL36 Should your DAVID P
21. ur favorite music B3 Sound Sync Use with hypnosis and 6 5 relaxation CDs for deep hypnotic induction meditation B4 Sound Sync Use with hypnosis and 7 8 relaxation CDs for deep hypnotic induction meditation B5 Sound Sync Use with recorded sporting 14 events or lectures for sports hypnosis and game CDs B6 Sound Sync Use with energizing music 18 lectures or sports recordings Sessions C1 to C6 in Library 2 are empty for user designed sessions to be saved and stored Page 16 BEFORE YOU CALL FOR REPAIRS If PWR light is dim and PAL36 is unresponsive Light 1 flashes then PAL36 shuts off PAL36 does not turn on PWR light not on Lights in eyeset are on left side only Tones in headphone are on left side only sound hollow No sound from audio player Download is not recognized Session runs but no lights and or tones on start up but can be adjusted manually Means PAL36 is in standby Battery is low Battery is dead Eyeset not plugged in completely Headphone not plugged in completely Plugged into audio player incorrectly Audio player improperly plugged in Volume too high too low Preferences have been set saved at zero Page 17 Response Turn off PWR switch then turn PWR switch back on Replace battery or use adapter Replace battery or use adapter Check eyeset connection Check headphone connection Check all connections to audio player Check a

Download Pdf Manuals

image

Related Search

Related Contents

(45 cm (51.7 cm  取扱説明書  anleitg-deutsch  PDF –>> Principales Modificaciones ICT  MINISTERIO DE DEFENSA CORPORACIÓN DEL SEGURO  User Manual - Lojas Colombo  Samsung U28E850R Kasutusjuhend  for Water Quality Monitoring in Cape Cod Bay 2012 – 2013  Bedienungsanleitung Husqvarna TS 342  マイコンキットドットコム www.MYCOMKITS.com  

Copyright © All rights reserved.
Failed to retrieve file