Home
FCC Statement Trademarks
Contents
1. Load Default Update Firmware TECHNICAL SPECIFICATIONS PHYSICAL SPECIFICATIONS CONNECTOR PINOUTS ORDERING INFORMATION User s Manual 21 22 23 24 25 26 27 28 29 30 16 Port Web Smart Ethernet Switch Product Overview Hs EET Ed Figure 1 16 Port Web Smart Ethernet Switch Package Contents When you unpack the product package you shall find these items listed below The 16 Port Switch One AC power cord v User s Manual Please inspect the contents and report any apparent damage or missing items immediately to your authorized reseller User s Manual 5 16 Port Web Smart Ethernet Switch Product Features PROVIDES 16 10 100MBPS PORTS USING RJ 45 CONNECTORS AN OPTIONAL SINGLE PORT FIBER MODULE ALLOWS 100BASE FX MULTI MODE FIBER WITH SC ST MT RJ VF 45 OR LC CONNECTOR 100BASE FX SINGLE MODE FIBER WITH SC OR ST CONNECTOR 100BASE BX WDM SINGLE MODE FIBER WITH SC CONNECTOR AUTO NEGOTIATION FOR SPEED AND DUPLEX MODE ON TX PORTS AUTO MDIX FOR ALL TX PORTS 4096 MAC ADDRESSES 1 5M BITS BUFFER MEMORY STORE AND FORWARD MECHANISM TRUE NON BLOCKING ARCHITECTURE FULL WIRE SPEED FORWARDING RATE BROADCAST STORM FILTERING CONTROL BACK PRESSURE AND IEEE 802 3x COMPLIANT FLOW CONTROL SYSTEM IP ADDRESS PORT VLAN TRUNKING OOS MODE AND QOS PRIORITY SETTINGS THROUGH THE WEB BASED BROWSER PRESS THE F
2. FRONT PANEL PORT AND POWER STATUS LEDS STANDARD 19 RACKMOUNT SIZE ONE UNIT IN HEIGHT User s Manual 24 Port Web Smart Ethernet Switch Front Panel Display The LED indicators on the front panel provide you with instant feedback on each port status and help you monitor and troubleshoot the switch BL Figure 2 Front Panel LEDs Power This LED comes on when the switch is properly connected to power and turned on Push Button The push button is located at the right side of port 24 on the 24 Port Switch Depress this button to use twisted pair port 24 and press this button to use the 100Base FX module IP RESET Push Button Press the Front panel IP RESET push button around five seconds to reset the Ethernet Switch back with the default IP Address Port Status The RJ 45 ports are numbered from 1 to 24 on the 24 Port Switch The LEDs are located on the ports of the switch displaying status for each respective port Please refer to the table below for more information Consult the following table for details Before you use this table for troubleshooting make sure the switch is properly connected to power and tumed on User s Manual 7 24 Port Web Smart Ethernet Switch Physical Ports The 24 Port Switch has twenty four 10 100Mbps ports using RJ 45 connectors and provides one slot for the optional single port fiber module The optional module allows fiber type multi mode or
3. Port VLAN Trunking Save Configuration Load Default DIT Refresh Click the Refresh On or Refresh Off button to or not to refresh back to the last saved settings of the ports lt Note gt It is recommended to change the Refresh On button to Refresh Off while you change the settings of the ports The Refresh On will refresh the settings of the ports shown on the screen around every ten seconds Mode Choose AUTO 10HD 10FD 100HD or 100FD for the ports Flow Control Choose Enable or Disable to enable or disable the flow control of the ports Transmit Receive Choose On or Off to turn on or off transmit receive of the ports Apply Click the Apply button and apply the new settings of the ports User s Manual 17 24 Port Web Smart Ethernet Switch 7 8 5 a a Tol a Configuration 6 F System Ch E z System Change y id r r IP Configuration T Ti BG Port c 6 a r r r VLAN B r r Trunking r ri ir Save Configuration r r Load Default r r r r r r r F ST Dane Damme VLAN Click and choose the ports to be added into the VLAN groups Apply Click the Apply b
4. port fiber module The optional module allows fiber type multi mode single mode or WDM single mode fiber and connector SC ST MT RJ VF 45 or LO at user s discretion UNDERSTANDING FRONT PANEL DESIGN Power LED On Power feeding in Off Power switched off Improper connection Port LED Link ACT On valid network connection Flashing Transmitting or receiving data AGT stands for ACTIVITY Off Neither connection nor activity Speed On A valid 100Mbps connection Off A valid 10Mbps connection 100FX BXI Link ACT valid network connection Port LED Flashing Transmitting or receiving data AGT stands for ACTIVITY Off Neither connection nor activity 8 User s Manual 16 Port Web Smart Ethernet Switch Installation Selecting a Site for the Equipment As with any electric device you should place the equipment where it will not be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 32 and 113 degrees Fahrenheit 0 to 45 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength Make sure that the equipment receives adequate ventilation
5. single mode fiber and connector SC ST MT RJ VF 45 or LC at user s discretion UNDERSTANDING FRONT PANEL DESIGN Power LED On Power feeding in Off Power switched off Improper connection Console LNK On A valid network connection Port LED LNK stands for LINK Off No connection ACT Flashing Transmitting or receiving data ACT stands for ACTIVITY Off Neither transmitting nor receiving data Port LED LNK ACT On A valid network connection LNK stands for LINK Flashing Transmitting or receiving data ACT stands for ACTIVITY Off Neither connection nor activity SPEED On A valid 100Mbps connection Off A valid 10Mbps connection 100FX Port LNK On A valid network connection ED LNK stands for LINK Off No connection ACT Flashing Transmitting or receiving data ACT stands for ACTIVITY Off Neither transmitting nor receiving data 8 User s Manual 24 Port Web Smart Ethernet Switch Installation Selecting a Site for the Equipment As with any electric device you should place the equipment where it will not be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 0 to 45 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should no
6. 10 Eile Edit View Favorites Tools Help ve Favorites Ethernet Switch Configura t 3 di Pagev Safety Tools v 3 Configuration System IP Address Switch Configuration Port VLAN Trunking QoS Mode QoS Priority Load Default Update Firmware Internet SYSTEM The System parameters can be displayed by clicking the System selection in the left sub menu User s Manual 17 16 Port Web Smart Ethernet Switch Go e 192 168 1 10 Elle Edit View Favorites Tools Help we Favorites Ethernet Switch Configuration Page Bi 3 Page v Safety Toolsv v 3 System Configuration Configuration System Switch Name New Password Retype New VLAN Password IP Address Port Trunking QoS Mode v1 05 QoS Priority 00 0 b3 11 01 05 Load Default Update Firmware Update e Switch Name Type a switch name for this Ethernet Switch e New Password Enter a user defined password and change the factory default password e Retype New Password Retype the new password e Update Click the Update button and apply the new System settings 18 User s Manual 16 Port Web Smart Ethernet Switch IP ADDRESS The IP Address parameters can be displayed by clicking the IP Address selection in the left sub menu Ethernet Switch Configuration Page Windows Internet Explorer EEK 65 le 192 168 1 10 Eile Edit View Favorites Tools Help ve Favorites Ethernet S
7. 25 24 Port Web Smart Ethernet Switch Product Overview J Figure 1 24 Port Web Smart Ethernet Switch Package Contents When you unpack the product package you shall find these items listed below The 24 Port Switch v One AC power cord v User s Manual Please inspect the contents and report any apparent damage or missing items immediately to your authorized reseller User s Manual 5 24 Port Web Smart Ethernet Switch Product Features o PROVIDES 24 10 100MBPS PORTS USING RJ 45 CONNECTORS AN OPTIONAL SINGLE PORT FIBER MODULE ALLOWS 100BASE FX MULTI MODE FIBER WITH SC ST MT RJ VF 45 OR LC CONNECTOR 100BASE FX SINGLE MODE FIBER WITH SC CONNECTOR AUTO NEGOTIATION FOR SPEED AND DUPLEX MODE ON TX PORTS 8192 MAC ADDRESSES 1 5M BITS BUFFER MEMORY AUTO MDIX FOR ALL TX PORTS STORE AND FORWARD MECHANISM TRUE NON BLOCKING ARCHITECTURE FULL WIRE SPEED FORWARDING RATE BROADCAST STORM FILTERING CONTROL BACK PRESSURE AND IEEE 802 3x COMPLIANT FLOW CONTROL SYSTEM IP CONFIGURATION PORT PORT BASED VLAN AND PORT BASED TRUNKING SETTING THROUGH THE WEB BASED CONSOLE PORT FRONT PANEL PUSH BUTTON TO CHOOSE 100BASE FX OR PORT 24 PRESS THE FRONT PANEL IP RESET PUSH BUTTON FOR FIVE SECONDS TO RESET THE ETHERNET SWITCH BACK TO THE DEFAULT IP ADDRESS THE PORT VLAN AND TRUNKING SETTINGS WILL REMAIN THE SAME AS WHEN THEY WERE LAST SAVED
8. 62 5um RJ 45 LC 100Base FX SMF Up to 9 or 10 1008 ST SC 100Base FX WDM SMF Up to 9 or 10 40km SC i The maximum node to node network distance isin full duplex operation ii MMF denotes Multi Mode Fiber SMF denotes Single Mode Fiber User s Manual 25
9. Do not block the ventilation holes on each side of the switch or on the rear of the equipment The power outlet should be within 6 feet 1 8 meters of the switch User s Manual 9 16 Port Web Smart Ethernet Switch Installation and Placement Instructions MOUNTED TO 19 INCH STANDARD RACK Locate the accessories supplied in the product package Use the rackmount brackets and screws to install the switch into any EIA 19 standard rack Step 1 Attach the brackets to each side of the chassis Step 2 Apply the screws to each side and secure them tightly Step 3 Carefully position the switch into the rack Step 4 Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack Step 5 Proceed to the Connecting to Power section DESKTOP OR ANY FLAT SURFACE The switch can sit on desktop or any flat surface with adequate space and ventilation If you want to place it onto shelf make sure the shelf can withstand the weight of the switch Step 1 Simply put the switch on the desired place Step 2 Ensure the switch receives good ventilation Step 3 Proceed to the Connecting to Power section 10 User s Manual 16 Port Web Smart Ethernet Switch Optional Fiber Module Installation Consult the following illustrations before installation Step 1 Make sure the power is switched off The module is not hot swappable may cause electric shock or any pos
10. RJ 45 connectors Figure 5 RJ 45 Connector and Cable Pins The following table lists the pinout of 10 100Base TX ports Connector Pin Out Pin Regular Ports Uplink port 1 Output Transmit Data Input Receive Data 2 Output Transmit Data Input Receive Data 3 Input Receive Data Output Transmit Data 4 NC NC 5 NC NC 6 Input Receive Data Output Transmit Data 7 NC NC 8 NC NC User s Manual 29 16 Port Web Smart Ethernet Switch Ordering Information 16 Fixed Ports Single Port Module Cable Cable 125um ETES Distance Speed oet AE Distance v 100Base TX 100m 100Base FX MMF 2km 50um or 62 5um Cat 5 or better SC UTP STP 1008659 2am ha mor OHM RJ 45 ST 100Base FX MMF 2km OR 50um or 62 5um MT RJ 100Base FX MMF 2km 10Base T 50um or 62 5um Cat 3 4 5 or EES EG ase better UTP STP 80 or 62 5um RJ 45 LC 100Base FX SMF Up to Sum or 10um 100km ST SC 100Base BX WDM SMF Up to 9um or 104m 40km SC i The maximum node to node network distance is in full duplex operation MMF denotes Multi Mode Fiber SMF denotes Single Mode Fiber 30 User s Manual 24 Port Web Smart Ethernet Switch FCC Statement The FCC Federal Communications Commission restricts the amount of radio frequency emission and radiation coming from computer equipment The e
11. Update Firmware Internet Click the Update button to update firmware to the switch 26 User s Manual 16 Port Web Smart Ethernet Switch Technical Specifications Applicable Standards Fixed Ports Optional 1 port Module Type Speed Switching Method Performance Chassis LED Indicators 16 Port Web Smart Ethernet Switch IEEE 802 3 10Base T IEEE 802 3u 100Base TX FX Sixteen ports for the 16 Port Switch 100Base FX multi mode single mode module or 100Base BX WDM single mode module 100Base TX FX BX 200Mbps for full duplex 100Mbps for half duplex 10Base T 20Mbps for full duplex 10Mbps for half duplex Store and Forward 148 810pps forwarding rate per port for 100Mbps 14 880pps forwarding rate per port for 10Mbps Power TX port Link ACT Speed 2 LEDs FX port Link ACT 1 LED User s Manual 27 16 Port Web Smart Ethernet Switch Physical Specifications 16 Port Web Smart Ethernet Switch Dimensions 440mm W 206mm D x 44mm H 7 32 W x 8 11 D x 1 73 Hy 19 rack mount size 1U high Weight 2 8Kg 6 16lbs Power Input 100 240VAC 50 60Hz Power 12W Max Dissipation Operating OC 45 C 32 F 113 Temperature Storage 10 70C 14 F 158 F Temperature Humidity 5 95 non condensing Emissions FCC Part 15 Class A CE Mark Class A 28 User s Manual 16 Port Web Smart Ethernet Switch Connector Pinouts Pin arrangement of
12. and speed considerations Step 3 Connect one end of the cable to the switch and the other end to a desired device Step 4 Once the connections between two end devices are made successfully turn on the power and the switch is operational 12 User s Manual 16 Port Web Smart Ethernet Switch NETWORK SEGMENTATION The maximum segment distance between a node and a directly connected switch port on 100Base FX network is 100km using 10 125 or 9 125 um single mode fiber optic cable It is capable of 8 maximum span of 2km when 62 5 125 or 50 125 um multi mode fiber optic cable is used Cable Specifications Table Ethernet Connector Port Cable Max ME mel ce Duplex 10Base T RJ 45 10 20 Cat 3 40r5 100m Mbps UTP STP 100Base TX RJ 45 100 200 Cat 5 100m Mbps UTP STP 100Base FX ST SC 100 200 50 or 2 to Multi mode MT RJ vF Mops 62 5 125um a 45 LC multi mode fiber 100Base FX ST SC 100 200 9or Up to Single mode Mbps 10 125um 100km single mode fiber 100Base BX SC 100 200 9 or oe WDM Mbps 10 125 i Single mode single mode fiber User s Manual 13 16 Port Web Smart Ethernet Switch Switch Configuration Setting up Web Based Browser Interface The Ethernet Switch provides a browser interface that lets you configure and manage the Ethernet Switch from a Web browser such as Microsoft Internet Explorer or Netscape Navigator remotely By connecting to any port of this Ethern
13. 16 Port Web Smart Ethernet Switch FCC Statement The FCC Federal Communications Commission restricts the amount of radio frequency emission and radiation coming from computer equipment The equipment introduced in this manual has been tested and found to comply with the limits for a Class digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in 8 commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in 8 residential area is likely to cause harmful interference in which case the user is required to correct the interference at his her own expense Any changes or modifications not expressly approved by the manufacture would void the user s authority to operate the equipment Trademarks Product names mentioned in this manual may be trademarks or registered trademarks of those products All trademarks or brand names mentioned are properties of their respective companies User s Manual 1 16 Port Web Smart Ethernet Switch Preface This manual describes how to install and use the 16 Port Web Smart Ethernet Switch The TX ports of the switch introduced here auto negotiates the presence of 10 100Mbps and full hal
14. Page Windows Internet Explorer EEK Gor e 192 168 Eile Edit View Favorites Tools Help i sk Favorites Ethernet Switch Configura 81 mh page Safety Toolsv v 3 10 v 4 gt r Configuration System IP Address Port VLAN Trunking 005 Mode QoS Priority Load Default Update Firmware Class of Service Configuration M Set high priority on Port Base mode or Enable VLAN tag IP DS support Port VLAN Port VLAN Base Tag Base Tag Port NolMode IP DS Port No Mode IP DS er 10 11 2 6 gt 1 As long as any of three COS schemes 802 1Q VLAN Tag IP TOS DS or Port Base is mapped to high the data packet will be treated as the high priority 2 The Diffsev s queue 10 18 26 34 46 48 56 are high priority Others is low priority 3 When use VLAN tag priority queue 0 3 are low priority queue 4 7 are high priority Internet Click and choose Port Base VLAN Tag and or IP DS for Port No 1 17 Update Click the Update button and apply the new settings of the QoS Priority 24 User s Manual 16 Port Web Smart Ethernet Switch LOAD DEFAULT The Load Default parameters can be displayed by clicki
15. RONT PANEL IP RESET PUSH BUTTON TO RESET THE ETHERNET SWITCH BACK TO THE DEFAULT SYSTEM AND IP ADDRESS SETTINGS THE PORT VLAN TRUNKING OOS MODE AND OOS PRIORITY SETTINGS WILL REMAIN THE SAME AS WHEN THEY WERE LAST SAVED FRONT PANEL PORT AND POWER STATUS LEDS STANDARD 19 RACKMOUNT SIZE ONE UNIT IN HEIGHT User s Manual 16 Port Web Smart Ethernet Switch Front Panel Display The LED indicators on the front panel provide you with instant feedback on each port status and help you monitor and troubleshoot the switch ET E Ed Figure 2 Front Panel LEDs Power This LED comes on when the switch is properly connected to power and turned on IP Reset Push Button Press the Front panel IP Reset push button to reset the Ethernet Switch back with the default User Name Password IP Address Netmask and Gateway settings Port Status The RJ 45 ports are numbered from 1 to 16 on the 16 Port Switch The LEDs are located on the front panel of the switch displaying status for each respective port Please refer to the table below for more information Consult the following table for details Before you use this table for troubleshooting make sure the switch is propery connected to powerand tumed on User s Manual 7 16 Port Web Smart Ethernet Switch Physical Ports The 16 Port Switch has sixteen 10 100Mbps ports using RJ 45 connectors and provides one slot for the optional single
16. a you have changed since the last Save operation Without clicking Ok button the switch does not save any changes you may have made 20 User s Manual 24 Port Web Smart Ethernet Switch LOAD DEFAULT Configuration System Change IP Configuration Port 2 An we me Kaj oe Trunking Save Configuration Load Default DOLAC Click Load Default Click the Ok or Cancel button to or not to load the default settings lt Note gt Once the Ok button is selected all last saved Port VLAN and Trunking setting will revert back to the default settings User s Manual 21 24 Port Web Smart Ethernet Switch Technical Specifications Applicable Standards Fixed Ports Optional 1 port Module Type Speed Switching Method Performance Chassis LED Indicators 24 Port Web Smart Ethernet Switch IEEE 802 3 10Base T IEEE 802 3u 100Base TX FX Twenty four ports for the 24 Port Switch 100Base FX multi mode or single mode module 100Base TX FX 200Mbps for full duplex 100Mbps for half duplex 10Base T 20Mbps for full duplex 10Mbps for half duplex Store and Forward 148 810pps forwarding rate per port for 100Mbps 14 880pps forwarding rate per port for 10Mbps Power LED For Console Port LNK ACT 2 LEDs For ports LNK ACT SPEED 2 LEDs 22 User s Manual 24 Port Web Smart Ethernet Switch Physical Specifications Dimensions Weight Power Input Pow
17. at lets you configure and manage the Ethernet Switch from a Web browser such as Microsoft Internet Explorer or Netscape Navigator remotely By connecting to the Ethernet Switch s console port you can access the Ethernet Switch s web interface applications directly in your web browser by entering the default IP address of the Ethernet Switch 192 168 1 10 You can then use your web browser to list and manage the Ethernet Switch configuration parameters from one central location Logging on to The Ethernet Switch SWITCH IP ADDRESS In your web browser specify the default IP address of the Ethernet Switch 192 168 1 10 USER NAME Enter the factory default user name admin PASSWORD Enter the factory default password no password press Enter directly Otherwise enter 8 user defined password if you followed the instructions later and changed the factory default password 14 User s Manual 24 Port Web Smart Ethernet Switch igrunnen Page Micoosuft 16 8 1 Eg los ajx ea S Aaaa STE Aides fa Ho 019 16 10 a Configuration System Change IP Configuration Port VLAN Trunking Save Configuration Load Default e ad 17 SYSTEM CHANGE The System Change parameters can be displayed by clicking the System Change button in the left sub menu ETE s on Page Mic kanst Bok BUE 2 AAS RAS TO Switch Nome Configuration Nov Password I System C
18. d choose the VLAN Group No 01 08 Member Port Click and choose the Member Port 01 17 to be added into the VLAN Group No 01 08 Comment Type Comment for VLAN Group No 01 08 User s Manual 21 16 Port Web Smart Ethernet Switch Update Click the Update button and apply the new settings of the VLAN groups TRUNKING The Trunking parameters can be displayed by clicking the Trunking selection in the left sub menu Ethernet Switch Configuration Page Windows Internet Explorer EEK GO r le ntr 192 168 1 10 Beklen CSE Eile Edit View Favorites Tools Help we Favorites Ethernet Switch Configura 8 8 HA page Safety Toolsv v 3 Trunk Configuration Configuration Trunk Hash Algorithm Selection O Port ID O SA ODA amp DA Poti Port2 Port3 Port4 System IP Address Trunko Port VLAN Trunking QoS Mode 1 Selecting one port for a tunk will treated as a void setting 2 The trunk group members must are also vlan members QoS Priority 3 Don t connect both trunks channels to a single switch this will cause unlimited traffic loop once a broadcast packet is coming to any port of the switch Load Default Update Firmware Trunk Hash Algorithm Selection Click and choose Port ID SA DA or SA amp DA Trunk Hash Algorithm TrunkO Click and choose Porti Port4 to be added into the Trunko Trunki Cl
19. e 61 1 Asol tom Fu Auto 100M Ful 8 room F 9 Auto 100M Fur red 100M Ful Auto TOOM Ful 3 Auto 100m Fur 100M Auto 100m Fur Auto 100M F Auto 100M Ful Je TO FA Port No Choose Port No 01 17 Auto Nway Choose Enable or Disable to enable or disable Auto Nway of the ports Speed Choose 100M or 10M speed for the ports Duplex Choose Full or Half Duplex for the ports Pause Choose Enable or Disable to enable or disable Pause for the ports 20 User s Manual 16 Port Web Smart Ethernet Switch Backpressure Choose Enable or Disable to enable or disable Backpressure for the ports Update Click the Update button and apply the new settings of the ports VLAN The VLAN parameters can be displayed by clicking the VLAN selection in the left sub menu Ethernet Switch Configuration Page Windows Internet Explorer 6 e 192 165 1 10 vr x pr File Edit View Favorites Tools Help we Favorites Ethernet Switch Configuration Page Q ser Page Safety Toolsv v 3 Group VLAN Setting Configuration Group No System IP Address Member Porn Port VLAN Comment Trunking QoS Mode 005 Priority Group VLAN Member Load Default Update Firmware 1 The ports that are not selected belong to the same VLAN group 2 Please make sure the tank port in the same VLAN group numa Group No Click an
20. er Operating Temperature Storage Temperature Humidity Emissions 24 Port Web Smart Ethernet Switch 440mm W x 207mm D x 44mm H 17 32 W x 8 15 D x 1 73 H 19 rack mount size 1U high 2 8Kg 6 16lbs 100 240VAC 50 60Hz 11 74W Max 45 C 32 F 113 F 10 C 70 C 14 F 158 F 5 95 non condensing FCC Part 15 Class A CE Mark Class A User s Manual 23 24 Port Web Smart Ethernet Switch Connector Pinouts Pin arrangement of RJ 45 connectors Figure 5 RJ 45 Connector and Cable Pins The following table lists the pinout of 10 100Base TX ports Connector Pin Out Pin Regular Ports Uplink port 1 Output Transmit Data Input Receive Data 2 Output Transmit Data Input Receive Data 3 Input Receive Data Output Transmit Data 4 NC NC 5 NC NC 6 Input Receive Data Output Transmit Data 7 NC NC 8 NC NC 24 User s Manual 24 Port Web Smart Ethernet Switch Ordering Information 24 Fixed Ports Single Port Module Cable f Cable 125um We Cer Distance Speed Caner Distance 100Base TX 100m 100Base FX MMF 2km 50um or 62 5um Cat 5 or better SC 1008655 MMF ss 2km mor s m RJ 45 ST 100Base FX MMF 2km OR 50um or 62 5um MT RJ 100Base FX MMF 2km 10Base T ase 50um or 62 5um Cat 3 4 5 or re A better UTP STP 856 50 or
21. et Switch you can access the Ethernet Switch s web interface applications directly in your web browser by entering the default IP address of the Ethernet Switch 192 168 1 10 You can then use your web browser to list and manage the Ethernet Switch configuration parameters from one central location Logging on to The Ethernet Switch SWITCH IP ADDRESS In your web browser specify the default IP address of the Ethernet Switch 192 168 1 10 14 User s Manual 16 Port Web Smart Ethernet Switch amp Login Windows Internet Explorer DEAK Gora 192 168 1 10 vel ar DE Eile Edit View Favorites Tools Help ve Favorites Login R D dm Page Safety Toos v 3 User Name Password Internet USER NAME Enter the factory default User Name admin PASSWORD Enter the factory default password no password press lt Enter gt directly Otherwise enter 8 user defined password if you follow the instructions later and change the factory default password User s Manual 15 16 Port Web Smart Ethernet Switch Login Windows Internet Explorer vel r bing ler OO le vr 192 168 1 10 File Edit View Favorites Tools Help sk Favorites Login 8 8 page Safety Toos v 3 User Name admin Password RE 16 User s Manual 16 Port Web Smart Ethernet Switch Ethernet Switch Configuration Page Windows Internet Explorer CER O e 192 168 1
22. f duplex mode and auto MDIX In addition it allows an optional 100Base FX multi mode single mode or 100Base BX WDM single mode fiber module enabling long distance connection To get the most out of this manual you should have an understanding of networking concepts such as bridging IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX Fast Ethernet and local area networks LANS For more information about these topics please refer to the Appendices In this manual you will find Introduction on the Switch Product features Illustrative LEDs functions Installation instructions Specifications 2 User s Manual 16 Port Web Smart Ethernet Switch Table of Contents FCC STATEMENT TRADEMARKS PREFACE TABLE OF CONTENTS PRODUCT OVERVIEW FRONT VIEW PACKAGE CONTENTS PRODUCT FEATURES FRONT PANEL DISPLAY PHYSICAL PORTS Understanding Front Panel Design INSTALLATION SELECTING SITE FOR THE EQUIPMENT INSTALLATION AND PLACEMENT INSTRUCTIONS Mounted to 19 inch standard rack Desktop or any flat surface OPTIONAL FIBER MODULE INSTALLATION CONNECTING TO POWER CONNECTING TO YOUR NETWORK Cabling Network Segmentation SWITCH CONFIGURATION SETTING UP WEB BASED BROWSER INTERFACE LOGGING ON TO THE ETHERNET SWITCH Switch IP Address User Name Password MAIN MENU System IP Address Port A User s Manual 16 Port Web Smart Ethernet Switch VLAN Trunking QoS Mode QoS Priority
23. hange IP Configuration Version 1110 Mac Address Po 0300 002 Port VI LAN Trunking Save Configuration Load Default er ian e Switch Name Type a switch name and replace the current switch name with a new one Please restart your Computer once the Switch Name is replaced User s Manual 15 24 Port Web Smart Ethernet Switch and saved under Save Configuration by the new name lt Note gt Only a z A Z 0 8 under line amp Space can be acceptable totally can not exceed 16 characters e Password Enter a user defined password and change the factory default password lt Note gt Only a z A Z 0 8 under line amp Space can be acceptable totally can not exceed 16 characters e Apply Click the Apply button and apply the new System settings IP CONFIGURATION Configuration System Change IP Configuration Port VLAN Trunking Save Configuration Load Default ei Dane lem Refresh Click the Refresh button and refresh back to the last saved IP Configurations e IP Address Netmask Default Gateway You can see and change the IP Address Netmask and Default Gateway of the Ethernet Switch Apply Click the Apply button and apply the new IP Configurations 16 User s Manual 24 Port Web Smart Ethernet Switch Configuration System Change IP Configuration
24. ick and choose Port5 Port8 to be added into the Trunk1 Update Click the Update button and apply the new settings of the Trunking Groups 22 User s Manual 16 Port Web Smart Ethernet Switch OOS MODE The QoS Mode parameters can be displayed by clicking the QoS Mode selection in the left sub menu Ethernet Switch Configuration Page Windows Internet Explorer EEK GO le nw 192 1684 10 9 oon to Eile Edit View Favorites Tools Help se r pl PA Favorites Ethernet Switch Configura 89 3 tb gt Pagev Safety Tools v 3 Priority Mode Configuration Priority Mode Firstn First Service IP Address Mode OAll High before Low O Weight Round Robin Low weight 0 v High weight 0 v When the queue weight is set to 0 it will be treated as 8 System Port VLAN Trunking 005 Mode QoS Priority Load Default Update Firmware Click and choose First In First Service All High before Low or Weight Round Robin Priority Mode The Priority Mode will be treated as 8 when both Low weight and High weight of Weight Round Robin are set to 0 Update Click the Update button and apply the new settings of the QoS Mode User s Manual 23 16 Port Web Smart Ethernet Switch QOS PRIORITY The QoS Priority parameters can be displayed by clicking the QoS Priority selection in the left sub menu Ethernet Switch Configuration
25. ld have an understanding of networking concepts such as bridging IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX FX Fast Ethernet and local area networks LANS For more information about these topics please refer to the Appendices In this manual you will find Introduction on the Switch Product features Illustrative LEDs functions Installation instructions Specifications 2 User s Manual 24 Port Web Smart Ethernet Switch Table of Contents FCC STATEMENT TRADEMARKS PREFACE TABLE OF CONTENTS PRODUCT OVERVIEW FRONT VIEW PACKAGE CONTENTS PRODUCT FEATURES FRONT PANEL DISPLAY PHYSICAL PORTS Understanding Front Panel Design INSTALLATION SELECTING SITE FOR THE EQUIPMENT INSTALLATION AND PLACEMENT INSTRUCTIONS Mounted to 19 inch standard rack Desktop or any flat surface OPTIONAL FIBER MODULE INSTALLATION CONNECTING TO POWER CONNECTING TO YOUR NETWORK Cabling Network Segmentation SWITCH CONFIGURATION A SETTING UP CONSOLE PORT CONNECTION WEB BASED BROWSER INTERFACE LOGGING ON TO THE ETHERNET SWITCH Switch IP Address User Name Password MAIN MENU System Change IP Configuration 14 14 14 14 14 15 15 16 User s Manual 24 Port Web Smart Ethernet Switch Port VLAN Trunking Save Configuration Load Default TECHNICAL SPECIFICATIONS PHYSICAL SPECIFICATIONS CONNECTOR PINOUTS ORDERING INFORMATION User s Manual 23 24
26. lustrations before installation Step 1 Make sure the power is switched off The module is not hot swappable may caus electric shock or any possible damage to the switch if the powerisnot switched off Step 2 Remove the module from the static free container Step 3 Unscrew the cover plate of the expansion slot The slot for single port module is located at the right side of the switch Step 4 Remove the plate Keep it for future use if you decide to remove this module later Step 5 Carefully slide the module into the slot following the internal plastic guide rails Step 6 Once it is fully slid in snap in the module to make a proper connection Step 7 Fasten the module screws Step 8 Finally turn on the power Figure 3 Removal of cover plate Fiber module being installed User s Manual 11 24 Port Web Smart Ethernet Switch Connecting to Power Locate the supplied AC power cord Step 1 Connect the AC power cord to the receptacle at the back of the switch Step 2 Attach the plug into a standard AC outlet with a voltage range from 100 240VAC Step 3 The power LED on the front panel will then illuminate Figure 4 Rear view of the switch Connecting to Your Network CABLING Step 1 First ensure the power of the switch and end devices is turned off De may cause an electric shock or any possible ham to you if the poweris not switched off Step 2 Prepare cable with co
27. ng the Load Default selection in the left sub menu Ethernet Switch Configuration Page Windows Internet Explorer EEK Q Ahite 192 168 1 10 ta ogin toi_ Gel wn Pl File Edit View Favorites Tools Help ve Favorites Ethernet Switch Configura 8 A Hd Page Safety Toolsy v 3 Load Default Setting Configuration System Reset Switch IP Address Port VLAN Trunking 005 Mode QoS Priority Load Default Update Firmware Internet Clickthe Load button to load the default settings Click the Reset button to reset the switch Once the Load button is selected all last saved Port VLAN Trunking QoS Mode and QoS Priority settings will be reverted back to the default settings User s Manual 25 16 Port Web Smart Ethernet Switch UPDATE FIRMWARE The Update Firmware parameters can be displayed by clicking the Update Firmware selection in the left sub menu Ethernet Switch Configuration Page Windows Internet Explorer EEK Oe en 192 168 1 10 We r Eile Edit View Favorites Tools Help a ve Favorites Ethernet Switch Configura A 8 Hs Page Safety Toos v 3 Firmware Update 2 ssing the Update button please wait while the update request is being Configuration proces After update is completed the device will reboot automatically You can re login afterwards System IP Address Port Trunking QoS Mode QoS Priority Load Default
28. quipment introduced in this manual has been tested and found to comply with the limits for a Class digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in 8 commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in 8 residential area is likely to cause harmful interference in which case the user is required to correct the interference at his her own expense Any changes or modifications not expressly approved by the manufacture would void the user s authority to operate the equipment Trademarks Product names mentioned in this manual may be trademarks or registered trademarks of those products All trademarks or brand names mentioned are properties of their respective companies User s Manual 1 24 Port Web Smart Ethernet Switch Preface This manual describes how to install and use the 24 Port Web Smart Ethernet Switch The TX ports of the switch introduced here auto negotiates the presence of 10 100Mbps and full half duplex mode and auto MDIX In addition it allows an optional 100Base FX multi mode or single mode fiber module enabling long distance connection To get the most out of this manual you shou
29. rresponding connectors for each type of port in use Consult the table below for cabling requirements based on connectors and speed considerations Step 3 Connect one end of the cable to the switch and the other end to a desired device Step 4 Once the connections between two end devices are made successfully turn on the power and the switch is operational 12 User s Manual 24 Port Web Smart Ethernet Switch NETWORK SEGMENTATION The maximum segment distance between 8 node and 8 directly connected switch port on 8 100Base FX network 15 100km using 10 125 or 9 125 um single mode fiber optic cable It is capable of 8 maximum span of 2km when 62 5 125 or 50 125 um multi mode fiber optic cable is used Cable Specifications Table Ethernet Connector Port Cable Max Standards Speed Half Full Distance Duplex 10Base T RJ 45 10 20 Cat 3 4 or 5 100m Mbps UTP STP 100Base TX RJ 45 100 200 Cat 5 100m Mbps UTP STP 100Base FX ST SC 100 200 50 or Up to Multimode MT RJ VF Mops 62 5 125 um 2km 45 LC multi mode fiber 100Base FX ST SC 100 200 9 or 10 125 Upto Single mode Mbps um single 100km mode fiber 100Base FX SC 100 200 9 or 10 125 Upto WDM Mbps um single 40km Single mode mode fiber User s Manual 13 24 Port Web Smart Ethernet Switch Switch Configuration Setting up Console Port Connection Web Based Browser Interface The Ethernet Switch provides a browser interface th
30. sible damage to the switch if the powerisnot switched off Step 2 Remove the module from the static free container Step 3 Unscrew the cover plate of the expansion slot The slot for single port module is located at the right side of the switch Step 4 Remove the plate Keep it for future use if you decide to remove this module later Step 5 Carefully slide the module into the slot following the internal plastic guide rails Step 6 Once it is fully slid in snap in the module to make a proper connection Step 7 Fasten the module screws Step 8 Finally turn on the power Figure 3 Removal of cover plate Fiber module being installed User s Manual 11 16 Port Web Smart Ethernet Switch Connecting to Power Locate the supplied AC power cord Step 1 Connect the AC power cord to the receptacle at the back of the switch Step 2 Attach the plug into a standard AC outlet with a voltage range from 100 240VAC Step 3 The power LED on the front panel will then illuminate Figure 4 The back view of 16 Port Web Smart Ethernet Switch Connecting to Your Network CABLING Step 1 First ensure the power of the switch and end devices is turned off may cause an electric shock or any possible ham to you if the power 5 switched off Step 2 Prepare cable with corresponding connectors for each type of port in Use Consult the table below for cabling requirements based on connectors
31. t exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the switch or on the rear of the equipment The power outlet should be within 6 feet 1 8 meters of the switch User s Manual 9 24 Port Web Smart Ethernet Switch Installation and Placement Instructions MOUNTED TO 19 INCH STANDARD RACK Locate the accessories supplied in the product package Use the rackmount brackets and screws to install the switch into any EIA 19 standard rack Step 1 Attach the brackets to each side of the chassis Step 2 Apply the screws to each side and secure them tightly Step 3 Carefully position the switch into the rack Step 4 Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack Step 5 Proceed to the Connecting to Power section DESKTOP OR ANY FLAT SURFACE The switch can sit on desktop or any flat surface with adequate space and ventilation If you want to place it onto 8 shelf make sure the shelf can withstand the weight of the switch Step 1 Simply put the switch on the desired place Step 2 Ensure the switch receives good ventilation Step 3 Proceed to the Connecting to Power section 10 User s Manual 24 Port Web Smart Ethernet Switch Optional Fiber Module Installation Consult the following il
32. utton and apply the new settings of the VLAN groups lt Note gt All Ports have to be selected to one of the VLAN Groups those Port Ports were not selected will be notified by the alarm message which shows Non Identify VLAN Group On Port 18 User s Manual 24 Port Web Smart Ethernet Switch TRUNKING 11 12 ele 3311411135 ele 11 EGG Configuration System Change IP Configuration Port VLAN Trunking Save Configuration Load Default OLJ D iemet Trunking Group 1 Click and choose any four ports to be added into the Trunking Group 1 Trunking Group 2 Click and choose any four ports to be added into the Trunking Group 2 Apply Click the Apply button and apply the new settings of the Trunking Groups lt Note gt Each Trunking Group can not be selected more than four ports the alarm message will show Maximum Four Ports For Group 1 or 2 if it s exceeded User s Manual 19 24 Port Web Smart Ethernet Switch SAVE CONFIGURATION Adin E bee men 16a 8 Configuration System Change IP Configuration Port LJ ed es wa NEE Trunking Save Configuration Load Default DEEL Click Save Configuration Click the Ok or Cancel button to or not to save the configurations lt Note gt The Cancel button will discard any dat
33. witch Configurat D 1 din Pagev Safety Toolsy v 3 IP Configuration Configuration System IP Address IP Address Netmask Port Default Gateway VLAN Trunking QoS Mode QoS Priority Load Default Update Firmware IP Address Netmask Default Gateway You can see and change the IP Address Netmask and Default Gateway of the Ethernet Switch Update Click the Update button and apply the new IP Configurations Please relogin the switch with the new IP Configuration after you click the update button User s Manual 19 16 Port Web Smart Ethernet Switch PORT The Port parameters can be displayed by clicking the Port selection in the left sub menu Ethernet Switch Configuration Page Windows Internet Explorer E Jr 192 168 1 10 vr x File gdt View Favorites Tools Help we Favorites Ethemet Switch Configuration Page Q Page Safety Toolsv v 3 Port Configuration Configuration Port No Auto Nway Speed Duplex Pause Back Pressure gt 01 Enable v 100M w Ful Enable Enable System IP Address eds Port pi Current Status Setting Status ort Link Speed Duplex Flow Ctrl Nway Speed Duplex Pause Back Pressure VLAN Trunking 100m Full On Auto 100M Ful On QoS Mode Auto 100M Full On Oos Priority Load Default 1 2 3 Auto 100M Ful On 4 ano 100 4 Ful On 5 100M Update Firmwar
Download Pdf Manuals
Related Search
Related Contents
scil Vet ABC ™Hematology Analyzer LIGNES DIRECTRICES SUR LA PRÉPARATION DES PLANS UNIVERSITE KASDI MERBAH OUARGLA Mémoire MASTER Circolare apparecchi a pressione Lenovo ThinkPad Edge E430c User`s Manual - PLANET Technology Corporation. PBC17-14036 PBC45-14035 - English Français REPRODUCTOR MUTIMEDIA PARA VEHÍCULOS MANUAL DE Ⅲ−6.工作機械製造企業F社における設計製造時のリスクアセスメント DITI10305704 Copyright © All rights reserved.