Home
Micrografx Designer 7 - TS21COV.DSF
Contents
1. One below the keypad on the hand grip One above the belt clip on the hand grip and Two on either side of the belt clip c Carefully separate the upper housing from the lower housing CAUTION When separating the two housings be careful of the connecting leads between the two housings Place the two housings side by side with the keypad and transmitter receiver sides down to minimize any strain on these leads d Remove the two line cord lead screws on the circuit board near the belt clip end Gently pull the cord free of any obstructions Remove and discard e Position the individual lead tips of the new line cord so that the tips line up with the screw holes in the circuit board The red lead to the right screw labeled R Ring and the black lead to the left screw labeled T Tip Insert the screws and tighten Note Be careful not to over tighten the screws f Position the brass line cord strain relief bushing or ring on the line cord so that it is inside the housing and lines up with the line cord exit hole g Carefully close the two housings together being careful not to pinch any of the wires Insert the five housing mounting screws and tighten Note Be careful not to over tighten the screws Warranty 6 03 Harris Corporation warrants that the test set unit shall be free of any defects in parts or workmanship for a period of 18 months and the line cord for a period of twelve 12 mont
2. If rotary dial pulse signaling has been selected the desired number may be entered at any rate on the keypad digits will automatically be pulsed out at the correct rate To end the call return the T M switch to the M position 5 04 Last Number Redial Move the MODE switch to the PULSE position The last number dialed can be automatically redialed by using the following procedure the number cannot exceed 18 digits a Go on hook move the T M switch to the M position for at least 1 2 second b Move T M switch back to T position c Press the pound key and the number will be automatically redialed In the off hook mode if any key other than the button is pressed the previously stored number will be erased Note The redial memory has a two minute time limit after the Test Set has been disconnected from a working telephone line After two minutes the number will be lost from memory 5 05 Ground Start Line Seizure optional Pressing the GROUND START button connects together the ground green and ring red leads of the three conductor test cord 5 06 Operation On Low Voltage or Dry Circuits a Move the keypad switch to OUT This position bypasses the circuitry of the Test Set and increases the loop limit The keypad will not operate in this mode but all other functions operate normally b Move the T M switch to M Connect line leads to the circuit under test Verify that the circuit is idle Move the
3. refer to your company s practices or to ABC of The Telephone Volume 2 Chapters 13 14 and 15 CAUTION When testing circuits that are relatively close to the battery source the clicks may be loud enough to cause temporary acoustical shock if the receiver is held too tightly against the ear The TS21 is designed to rest comfortably on the shoulder with the receiver away from the ear It should be used in this position when listening for clicks 6 MAINTENANCE 6 01 Belt Clip Replacement The belt clip may be easily replaced in the field without opening up the Test Set The ordering number for the replacement belt clip is P3218 249 To replace the belt clip assembly a Place the Test Set on a firm and level working surface with the keypad up b Move the clip of the belt clip into an upward position to expose the two mounting screws and remove the screws Remove and discard the old belt clip c Position the new belt clip so that its screw mounting holes line up with the mounting holes in the Test Set Insert the screws and tighten Note Be careful not to over tighten 6 02 Line Cord Replacement The line cord may be replaced in the field by experienced personnel as the Test Set must be opened up exposing its electronic circuit boards To replace the line cord a Place the Test Set on a firm and level working surface with the keypad up b Remove the five housing screws located One above the keypad
4. T M switch to T for two way communications c When operating on low voltage or dry circuits a minimum of three volts DC talking battery is required Page 4 5 07 Troubleshooting The following troubleshooting procedures are based largely on the audible click heard in the receiver of the TS21 when the two Test Set leads are placed on battery potential and ground respectively or across the terminal of an electrically charged capacitor These clicks and other sounds can greatly help a skilled crafts person in locating open circuits shorts crosses and grounds a To locate a short circuit open one side of the telephone line and place the test set in the loop one lead to each side of the opened line On the CO side of the fault a loud click will be heard on the field side of the fault no click will be heard b Locating an open circuit is done by bridging the test set across the circuit line one test lead on tip the other on ring Moving away from the CO the fault is at the point where the loud click disappears c Continuity of each side of the loop may be verified by placing one of the line leads on a local ground and the other on the conductor in question On a good ring conductor a click will be heard on a good tip conductor an inductive hum will be heard due to the difference in ground potential between the CO ground and the local ground Note For a full discussion on these troubleshooting procedures
5. also provides last number redial and field replaceable line cords and belt clips This Test Set often called a butt in is a self contained line powered portable handset used by installers repair technicians and other authorized personnel for line testing and temporary communications 2 DESCRIPTION 2 01 Physical Characteristics Figure 1 a The housing A is injection molded of high impact polycarbonate which provides excellent insulating properties The case is designed to give rugged service and withstand the rough handling and shocks normally associated with craft tools b The back of the hand grip B is contoured and has a non slip surface freeing both hands while the Test Set rests on the shoulder c The keypad C has 12 buttons on a black plastic bezel that is recessed into the receiver end of the housing The recessed bezel provides physical protection to the keypad and prevents accidental button operation d The spring loaded belt clip D located on the transmitter end of the housing ensures a secure connection to a belt loop or D ring The belt clip may be replaced in the field see section 6 01 a Electrical Loop Limit DC Resistance Talk Mode Monitor Impedance Rotary Dial Output Pulsing Rate Percent Break Interdigit Interval Leakage During Break DTMF Output Tone Frequency Error Level per Tone Pair High versus Low Tone Difference b Physical Length Wid
6. Calle Plano Camarillo California 93012 8516 Telephone 805 987 9511 FAX 805 987 2547
7. P N 011722333 001 Issue 5 November 1996 HARRIS CORPORATION USER MANUAL T521 CRAFT TEST SET DESCRIPTION AND USE NOVEMBER 1996 mm HARRIS DRACON DIVISION P N Oll 722333 001 Issue 5 November 1996 USER MANUAL TS21 Craft Test Set Description and Use November 1996 m HARRIS DRACON DIVISION HARRIS CORPORATION 1996 Printed in USA HARRIS CORPORATION P N Oll 722333 001 Issue 5 November 1996 TS21 CRAFT TEST SET DESCRIPTION AND USE CONTENTS PAGE GENERAL sd cae tees ku aaa 1 A Housing 2 DESCRIPHON fetes daslsudaass kui dakse ga k si 1 a Non Slip Surface 3 CONTROLS AND INDICATORS 2 7 Ss E Test Cord Ay A CONNECTIONS iii rei 3 i a 5 OPERATION sedcscateereeageexsiecisegeausd 3 D Belt Clip 6 MAINTENANCE 6 0 lira 4 WARNING Good safety practices prohibit the connection of the TS21 Figure 1 Physical Characteristics and similar test sets to 117 volts AC commercial electrical power and should the TS21 be connected to commercial power all warranties are immediately voided e The test sets are equipped with several different cord configurations E The line cords may be replaced 1 GENERAL in the field see sections 4 and 6 02 1 01 The Harris Corporation s Dracon Brand TS21 Craft 2 02 Specifications Test Set employs the latest technology in integrated circuit design to provide both DTMF Touch Tone and dial pulse output The TS21
8. he line The M position allows line monitoring without disrupting conversations data or signaling Talk Monitor Switch Mute Button Ground Start Button Model No 21800 087 Polarity Button Figure 2 Voice and Polarity Controls b Mute M Button This non locking push button labeled M is located on the inside of the hand grip just above the transmitter When pressed this button mutes the transmitter eliminating sidetone and providing improved intelligibility through the receiver in noisy locations c Polarity Button This non locking push button labeled P is located on the inside of the hand grip just below the receiver When pressed the button will activate one of the polarity LEDs located at the top of the keypad showing the current polarity of a telephone line or a low voltage battery source See section 3 02 d d Ground Start Button optional Located between the MUTE button and the Polarity switch When pressed this small black button connects the ground green lead to the ring red lead of the special Page 2 three conductor ground start cord initiating a ground start line seizure 3 02 Keypad Controls and Indicators Figure 3 a Keys The 12 standard keys will send either DTMF tones or dial pulses depending on the MODE switch setting See b b MODE Switch This two position locking rocker switch labeled MODE is located on the lower right keypad bezel The s
9. hs from the date of manufacture if used under Harris operating specifications THIS IS THE ONLY WARRANTY MADE BY HARRIS CORPORATION AND IS MADE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IM PLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE Should any parts or workmanship prove defective Harris Corpora tion will repair with not used or reconditioned parts or replace the Product at Harris option at no cost to the Buyer except for Shipping costs from the Buyer s location to Harris location This is the Buyer s SOLE AND EXCLUSIVE REMEDY under the agree ment 6 04 This warranty does not extend to products which have been subjected to neglect accident or improper use nor to units which have been altered or repaired by other than authorized Harris Corporation personnel Return Of Equipment 6 05 To return the Test Set to Harris first obtain a Return Authorization Number from our Customer Service by calling 1 800 437 2266 This Return Authorization number must be clearly marked on the shipping label or the container will not be accepted by Harris See the sample label below To HARRIS CORPORATION 809 Calle Plano Camarillo California 93012 8516 Attention Customer Support RA XXXXXX CAUTION Do not use CRC Cable Clean or any similar chlorinated solvent on the TS22 Doing so will damage the test set Page 5 HARRIS CORPORATION 809
10. ld the depressed P button The green LED will light if the red test lead is connected to the ring negative side of the line and the black test lead is connected to the tip positive side of the line The red LED will light if the test leads are reversed that is with the red test lead connected to the tip positive side and with the black test lead connected to the ring negative side PIERCING PIN CORD STD P3218 028 ANGLED BED OF NAILS CORD ABN P3218 234 P3218 232 C O 346A PLUG CORD SP C O 346A PLUG AND RESISTOR CORD SPR BED OF NAILS CORD SBN P3218 024 P3218 233 GROUND START CORD 3W P3218 025 Figure 4 Cords Page 3 CAUTION Operation of the POLARITY button on a busy circuit may cause annoying clicks or service interruptions Operation of the switch on an idle telephone line may cause telephone line seizure 5 03 Dialing a Move the KEYPAD switch to the IN position Move the MODE switch to either TONE or PULSE depending on the type of dial signaling required Move the T M switch to the M position Connect the line cord clips to the telephone line Listen to verify that the telephone line is idle b Move the T M switch to T position and verify that dial tone is received when furnished Enter the desired number to be called on the keypad If tone signaling has been selected the tones associated with each digit will be generated as each respective button is pressed
11. lug and switchable 1500 ohms resistor and is approx imately 18 inches long When switched on the resistor is inserted in series with the ring side of the cord to simulate a long loop condition The plug allows the use of a variety of different test cords equipped with the matching 471A male connector Cord Number P3218 233 e Bed of Nails Cord SBN This cord is identical to the standard STD cord except that each alligator clip is equipped with a bed of nails in addition to an insulation piercing spike and the clips are not offset as are the STD clips Cord Number P3218 024 f Ground Start Cord 3W This cord consists of one red one black and one green fabric covered tinsel conductor approximately five feet long each fitted with an alligator clip of the type used on the standard cord Pressing the GROUND START button connects the green ground conductor to the red ring conductor inside the Test Set Cord Number P3218 025 5 OPERATION 5 01 Monitoring Move the T M switch to M KEYPAD IN OUT and MODE switches may be in either position and connect the line leads to the telephone line under test Monitoring may now be done without disrupting traffic Note The TS21 is not polarity sensitive and will function normally regardless of telephone line polarity 5 02 Polarity Check Move the T M switch to M Connect the line leads to the telephone line under test Verify that the telephone line is idle Press and ho
12. rvice interruptions e Last Number Dialed Button The pound key serves as a last number dialed button when the Polarity LEDs Keypad Keypad Switch x Last Number Redial Mode Switch Figure 3 Keypad MODE switch is in the PULSE position Pressing the key will redial the last number dialed Note The redial memory has a two minute time limit after the TS21 has been disconnected from a working telephone line After two minutes the number will be lost from memory 4 CONNECTIONS 4 01 Cords Figure 4 a Standard Cord with Piercing Pin STD This cord consists of one red and one black conductor each approximately five feet long Each conductor is fitted with an alligator clip offset 20 to minimize clip shorting The clips have insulation piercing spikes and a neoprene boot Cord Number P3218 028 b Angled Bed of Nails Cord ABN The angled Bed of Nails cord is similar to the STD cord except that each alligator clip is equipped with a bed of nails in addition to the insulation piercing spike Cord Number P3218 234 c Central Office Plug Cord SP This cord is fitted with a type 346A female plug and is approximately one foot long The plug allows the use of a variety of different test cords eguipped with the matching 471A male connector Cord Number P3218 232 d Central Office Plug and Resistor Cord SPR This cord is fitted with a type 346A female p
13. th Height Weight c Environmental Temperature Altitude Relative Humidity 2 kQ maximum at 48 VDC nominal 20 mA minimum loop current lt 300 Q similar to WECO 10131A and BECO 801 6 kQ minimum at 1 kHz 10 pps 0 5 pps 61 2 1000 ms typical gt 50 kQ 1 maximum 1 dBm maximum 9 dBm minimum 4 dB maximum 9 11 16 inches 24 6 cm 2 11 16 inches 6 83 cm 3 11 16 inches 9 37 cm 21 ounces 600 kg typical Operating 34 to 60 C Storage 40 to 66 C To 10 000 feet 5 to 95 Specifications subject to change without notice Page 1 2 03 Standard TS21 Models Model No Cord Type Ground Start Switch 21800 081 STD NO 21800 082 SBN NO 21800 084 SP NO 21800 087 SW YES 21800 088 SPR NO 21800 089 ABN NO Special production models are indicated by a number in place of the zero following the 180 281 384 etc These models are identical to their corresponding standard model except for color and logo See cord descriptions Section 4 3 CONTROLS AND INDICATORS 3 01 Voice and polarity controls Figure 2 a Talk Monitor T M Switch This rocker switch is located on the side of the test set The T TALK position establishes an off hook condition for dialing and talking as a common battery telephone The M MONITOR position removes the transmitter from the circuit and provides a high impedance coupling to t
14. witch selects the signaling output TONE for DTMF or PULSE for dial pulse c Keypad Switch This two position locking rocker switch labeled KEYPAD is located on the lower left keypad bezel With the switch in the IN position the Test Set operates as a telephone this mode is used for all normal communications The OUT position bypasses the Test Set circuitry including the keypad In this mode signaling is not possible but the TS21 will operate at very low voltages much like standard Test Sets currently in use The OUT position is recommended when testing at or near the loop limit 2 000 ohms at 48 volts DC or when testing on dry circuits The OUT position must be used when the circuit voltage is six volts or less such as when using tones or other test devices as a source of talk battery d Polarity LEDs These round LEDs one green and one red are located at the top of the keypad One LED will illuminate when the polarity button is pressed to indicate line polarity See section 5 02 The green LED will light if the red test lead is connected to the ring negative side of the line and the black test lead is connected to the tip positive side of the line The red LED will light if the test leads are reversed that is with the red test lead connected to the tip positive side and with the black test lead connected to the ring negative side CAUTION Operation of the P button on a busy circuit may cause annoying clicks or se