1. Digital reference frequenc Ramp up time f 201 Ramp down time 202 S 900 Stator resistance measure command C 100 off arameter save comman ial S 200 1 control from terminals S 200 2 3 4 reserved for serial line control e S 202 Source of speed reference S 202 3 reference from digital frequency S 203 S 202 1 reference from analog input Vedi I 200 Starting 1 Connect a potentiometer minimum resistance 4 7 kOhm for the speed reference terminals 9 10 11 2 Connect two contacts for the Run and Reverse commands closing on 15V terminals 4 and 5 for Run 4 and 7 for Reverse 3 Close the Run contacts to start the motor The motor starts and follows the set ramp to the set frequency default F 201 5 5 seconds Stopping The motor can be stopped in two ways 1 By de activating the Run command The motor stops with the factory default deceleration ramp F 202 5 seconds from max frequency to 0 Hz 2 Setting the speed reference potentiometer to 0 for manual control over motor stopping Warning If the motor is stopped in this way it remains live even when not rotating If the motor fails to run If the motor fails to start after the Run command first make sure that the connections specified above have been made correctly then check that the factory default parameters are suitable for the specifications of the motor USING THE PROGRAMMING KEY Transferring parameters from the invert
2. f Output torque greater than value setinP2a7 10 Current Lim Current imit exceeded in ramp oratspeed____ Analog input AN IN 1 1 200 I 210 only 1 and 3 1 xxx Analog signal configuration alore Without J5 Voltage 0 10V With J5 Current 0 20mA With J5 Current 4 20 mA 3 With J5 Current 4 20 mA with alarm if lt 4mA Note Alarms Over Current check the load and the ramp SHortCircuit check the motor wires insolution verso ground Over Voltage chech the ramp Under Vol tage check the power supply Motor overload check the cycle executed and data motor inserted Over Temperature check the fan For the other allarm code please refer to the user s manual 1DE MAGNO s p a tecnologie digitali elettroniche QUICK START SERIES DSA DIGITAL INVERTER Introduction DSA series digital inverters are designed for use with three phase asynchronous motors from 0 25 kW to 1 1 kW 230 V Basic inverter programming can be achieved using just the S parameters of the STARTUP menu Other menus provide all necessary parameters to customise the inverter for specific applications Refer to the manual for a complete description of these menus and parameters Ls Electrical equipment can be hazardous to personal safety It is essential to be fully acquainted with the operating instructions and controls of electrical equipment before attempting to operate it Equipment must
3. 39 044 343509 www tdemacno it MADSAX0030E0 V02 sw 0B 09 xx 00 CONNECTION DIAGRAMS POWER AND CONTROL TERMINALS TOP y SINGLE PHASE FEED SINGLE PHASE Single phase 50 Hz 60 Hz 5 FEED a 220 V 15 240 V 10 aopa F RO NT eee Function Led s COPYKEY oS Qa ps Yellow 168 3 ON Inverter power O O O O O Flashing Programming mode Men M Reset G Enter Display Green RUN command enabled and active Red Inverter allarm state 1 2 3 4 5 6 7 8 91011 JP 5 JP7 1516 17 Nisd IN AN V P Fitted IN AN A termina 8 10 11 Notused in standard version 15 16 17 Serial output if provided BOTTON a gt THREE THREE PHASE gt PHASE MOTOR gt MOTOR A FIT JP5 FOR USE WITH CURRENT ANALOG INPUT Control terminal Potentiometer N Programmable relay 15V EMISAS Cy ers tov OUTPUT 1100 z T OUT 1 c z uf gt 3 z z S 2 Z o GND M NON ac Eid a i el a IN14 IN2 IN3 IN4 epee GND FB FB JP5 fitted the ANALOG RS 485 if optional INPUT is a current input card fitted 1200 1 0 10V or 0 20 mA 2 4 20mA ee JP7 Limits ground JP5 regulation potential CONTROL CONNECTIONS TERMINAL N FUNCTION 230 Vac 0 2A 30Vdc 1A 15V _ 5 300mA Rel Common REL NC 3 1 Alarm Normally closed 15 V 4
4. 15V Potential IN2 6 Digital input2 1 001 3 EF_ 002_ 2 IN4 8 Digital input4 1 003_ 7 SFreq 7mMA 15V REV PNP logic GND___ 9 0 V potential for analog input Analog input ANIN1 Programmable analog input 1 1 200 1 Voltage Ri 20kOhm 10V Potential Current Ri 5000hm Converts Voltage input J5 not fitted to Current input J5 fitted JP7 Limits potential of earth terminals PARAMETRS MENU Use the keyboard to access the parameters Press M to display the desired menu Use the arrow ft up and arrow down keys to select the code of the parameter whose value you wish to display then press E to display that value d xxx Read only parameters display menu S xxx Basic inverter parameters setting menu Il xxx Programmable inputs and outputs setting menu ff xxx References and ramps setting menu P xxx Inverter functioning parameters setting menu A xxx PID block parameters setting menu C xxx Function execution menu for functions like parameter saving and inverter auto calibration NOTE Men S START UP groups together the parameters and functions necessary for quick and easy start up of the inverter and the controlled motor All the parameters in the STARTUP menu are duplicated in other menus Changes to any parameter in the STARTUP menu automatically change the same parameter in the other menu EDITING PARAMETERS Let us assume that we have powered the inverter on and that we wish to change the acceleration ramp
5. only be used by technical personnel who are qualified to do so who are fully acquainted with the standards for installing and operating equipment in compliance with all applicable safety standards and who are able to fully understand all safety related warnings Capacitors inside the equipment operate at dangerously high voltages Always wait at least 5 minutes after the equipment has been switched off before performing any work on it Dangerous voltages may be present at the power terminals even with the motor stopped These are terminals U V W L1 L2 Under certain control program conditions the machine can re start automatically after a power failure There are no user serviceable components inside the equipment Only the terminal cover must be removed during installation Warning Technical specifications Nominal Current Input Inverter Motor output absorbed voltage power power current perphase Inverter consumptio 2 ne peo oss as single sao EMC DSA series inverters are fitted with an internal EMC filter EN 55011 CI A as standard DSA Cl B internal filter can be fitted as an optional This data sheet provides a quick guide to the installation and operation of DVS inverters For advanced functions and for maximum safety always refer to the complete manual available on request TDE Macno s p a Via dell Oreficeria 41 36100 Vicenza VI Italy Tel 39 0444 343555 Fax
6. List of main parameters see the manual for the complete list D DISPLAY menu Description unit of measure Output frequency 0 1 Hz Reference frequency 0 1 Hz d 002 Output current rms 0 1A Output voltage rms 1 V Basic drive start up menu S START UP menu Description Arias S 150 Nominal motor current p 040 S 151 Pairs of motor poles p 041 Plated motor cos value p 042 Motor stator resistance ohm p 043 Automatic boost on off 1 0n p 122 450 Slip compensation p 100 S 451 Compensation time constant Drive digital analog input output settings menu INTERFACE menu Descrizione DEFAULT 1 000 Configure inputs IN 1 1 RUN 1 001 Configure inputs IN 2 3 Ext Fault NO 2 REVERSE 1 002 Configure inputs IN 3 7 Freq Sel 1 H100 Conigue ouputs OUTI PAD M Arm te aaa F200 Configure input ANIN RAA 1 voromto _ 201 AnaloginputOfset_ o o t202 Anaogmptean oS 203 Analog inputMin ve oS Multi speed and ramp settings menu F FREQ amp RAMP menu cod Desorption f 100 f 107 Digital frequencies f 116 Jogging frequencies Drive functioning parameter settings menu P PARAMETER menu P 004 Stop mode 0 to ramp 1 by inertia P 100 P 100 Slip compensation Slip compensation time constant s P 220 Enable Link DC control optim
7. er to the key Insert the key into the socket above the display Use the keyboard to select the C 041 parameter press fT arrow up then Enter The display reads out done for 2 seconds to confirm data transfer Transferring parameters from the key to the inverter Insert the key into the socket above the display Use the keyboard to select the C 040 parameter press ff arrow up then Enter The display reads out done for 2 seconds to confirm data transfer
8. ises deceleration preventing over voltage alarm 0 Disabled 1 PI limiter 2 Ramp freeze P 380 Number of autoreset attempts with 5 second pause P 400 External fault control mode 0 always detected Autoreset No 1 detected only in RUN mode Autoreset Na 2 always detected Autoreset Yes 3 detected only in RUN mode Autoreset Y s Digital inputs IN1 1 000 J IN2 I 001 J IN3 I 002 J IN4 I 003 Action performed by digital input when active Value 0 None Notactive SS 1 RUN RUN command to enable drive _ __ _ 2 Reverse ReverseReverse_speedcommand ____ 3 TEFNO EF NO External fault activelow 4 EFNC___ EFNC External fault active high _5 Alarm Reset Alarm reset Alarmresetcommand 6 Jog Jog frequency enable command F 116_ Freq Sel 1 Binary selection of multispeed function 13 Enable NO _ Enable NO Drive enable active low 14 Enable NC _ Enable NCDrive enable active high 26 Fast Stop Quick stopQuick stop ramp time F206 Digital output OUT 1 I 100 Action performed by digital input when active o ernea merere ors SC 1 Alam State _ Postve alarm signaling i 2 Nom Aarm Negative alarm signaling logo 3 Motor Running Active direction command Fwd or Rev 4 Motor Stopped Active direction command and frequency O0Hz 5 REV Rotation Reverse roton Oo o e Steady State Motoratspeed SSCS o rath
9. value F 201 from 5 factory default value to 10 seconds On power up the display reads out 000 Press M repeatedly to display menuF F 000 Use the arrowft Yup and arrow down keys to select code 201 F 201 Press E The value of the parameter f 201 AccTime 1 is displayed If the PRG LED is steadily lit the parameter value can be changed Press the arrow upft key until the display reads out 10 Press E to enter the new value This changes the active value for the acceleration ramp but does not save it the yellow LED flashes Press M to displayC Use the arrow ft Yup and arrow down keys to select the code C 000 Press E to confirm your choice The display reads outoff If the PRG LED is steadily lit the value can be saved Use the arrow ftup key to enable the function The display reads out Do Press E to confirm The display reads out done value saved STARTUP For the equipment to operate in safe conditions it must be installed and started up by suitably qualified personnel in com pliance with all relevant safety standards applicable to high current and high voltage electrical equipment Parameter settings Check the following parameters before starting up the inverter S START UP menu Basic drive start up menu Para ALIAS METER Description Mains voltage V p 020 Mains frequency Hz p 021 Maximum output voltage V p 061 Base frequency Hz p 062 START amp STOP command source 1 terminals p 000